13
Valid as of Software Version 1.88 International Version Not valid for the US ZEISS IOLMaster 700 Manual Entry of Toric IOLs Quick Guide

ZEISS IOLMaster 700

  • Upload
    others

  • View
    47

  • Download
    0

Embed Size (px)

Citation preview

Page 1: ZEISS IOLMaster 700

Valid as of Software Version 1.88International VersionNot valid for the US

ZEISS IOLMaster 700Manual Entry of Toric IOLs

Quick Guide

Page 2: ZEISS IOLMaster 700

22

Valid as of Software Version 1.88, valid only in complement to ZEISS IOLMaster User Manual

Table of Contents

Introduction to this Quick Guide 3

Lens Manager: First Steps 4

Adding Toric IOLs with Inconsistent CYL Power Steps and/or Individual CYL Power Labeling 5

Alcon Acrysof® Toric SN6AT (2-9) 7

Alcon PanOptix® Toric (TFNT20-60) 7

J&J TECNIS® Toric (ZCT 100-800) 8

J&J TECNIS® Symfony® Toric (ZXT 100-600) 8

Hoya 351 Toric (T3-9) 8

Hoya Vivinex™ XY1A Toric (T2-9) 9

ZEISS AT LARA toric 929M/MP 9

Adding Toric IOLs with Consistent CYL Power Steps 10

ZEISS AT LISA tri toric 939M/MP 11

Page 3: ZEISS IOLMaster 700

33

Introduction to this Quick Guide

This guide provides information and instructions on manual entry of toric IOLs in the ‘Lens Manager’

(found under “Settings”) of the IOLMaster® 700 from ZEISS as of software version 1.88.

As different IOL manufacturers offer toric IOLs in different and sometimes inconsistent toric power

steps, the ZEISS IOLMaster 700 allows users to manually add IOLs, define the delivery range and

specifically define the spherical equivalent (SE) range, SE increment, cylinder (CYL) format, CYL range

and CYL increment.

The process of entering new toric IOLs may take some time, during which the ZEISS IOLMaster 700

cannot be used. Depending on how many IOLs and users are to be entered and the complexity of the

IOL definitions, the required time may vary between a few minutes and more than an hour.

This guide explains IOL configurations in the lens manager for toric IOLs with inconsistent step

sizes (e.g. Alcon IOL) and consistent step sizes (e.g. ZEISS IOL). It also provides respective examples.

For toric IOLs not listed in this guide, please use the examples below as templates and refer

to the respective IOL manufacturer or your ZEISS representative for further information.

Availability of IOLs and their respective power ranges and step sizes can vary regionally.

All IOL information in this document is provided without a guarantee of correctness; the

user is responsible for the correctness of all manual inputs.

All powers must be entered according to IOL labelling standards, i.e. powers are meant

to be entered on lens-plane, NOT on corneal plane, as provided by the respective IOL

manufacturer.

ZEISS also provides a database of pre-set IOLs. Users can download this via: https://www.zeiss.com/

meditec/int/resource-center/cataract-services/optimized-lens-constants.html. The same data set is

shipped with all software updates and with all new ZEISS IOLMasters. It can also be requested from the

ZEISS representative. This set of data can then be imported in whole or parts via the “lens manager”

import settings. For lenses included on this dataset manual configuration is no longer required,

unless users want to change IOL constants or ranges. If choosing to download and utilize these IOL

definitions, users are still encouraged to contact their respective IOL representative to ensure the

dataset represents the most recent updates for the manufacturer’s IOL and to modify the definitions if

needed.

If you want to use your own IOL constants with IOLs that are available in the ZEISS database, please

consider importing the IOL automatically via the download and then change the IOL constants. This is

likely to save you time in the process.

Page 4: ZEISS IOLMaster 700

44

1. Log in with the respective surgeon’s account in order

to have access to the Lens Manager settings

Note:

The following procedure needs to be repeated per surgeon

account.

2. Go to Settings > Advanced Settings > IOL Management >

Click on ‘Start lens manager’

3. Click on ‘Add IOL’

4. Follow the instructions as described

in the examples below

Lens Manager: First Steps

Page 5: ZEISS IOLMaster 700

55

Note:

• Formula constants used in fi gures below are an example. The user is responsible for correct entry of IOL constants,

power steps and ranges according to each IOL.

• Please contact the IOL manufacturer for optimized IOL formula constants or use your own personalized constants.

• The Alcon SN6AT (2-9) (and many other toric IOLs) lens constants and delivery ranges shown in this example can be

automatically imported into the IOLMaster 700 via the USB drive provided by ZEISS and/or downloaded from the ZEISS

website: https://www.zeiss.com/meditec/int/resource-center/cataract-services/optimized-lens-constants.html.

• If an IOL is imported via the download, you need not follow the steps below. Please confi rm the correctness of the data

with the respective IOL manufacturer’s representatives.

Adding Toric IOLs with Inconsistent CYL Power Steps and/or Individual CYL Power Labeling

1. Enter the IOL information – i.e. Manufacturer,

Name of IOL, IOL constants, etc.

2. Select IOL parameter “Toric”

3. Choose, if the IOL is delivered with Spherical Equivalent

Steps (SE) or with Spherical Steps (Sph) (In this example

SE is chosen)

4. Click on ‘Delivery range…’

Page 6: ZEISS IOLMaster 700

66

5. In the delivery range menu, delete the pre-populated

default settings (-100 to +100D) by pressing the trash can

icon

6. For each row in the respective IOL’s table at the bottom:

Enter the SE range, SE increment, Cylinder format (Single),

Cylinder Range and Cylinder increment as well as label

and press Add

Note:

“Single” does not refer to astigmatism correction range on

the cornea plane. It refers to the cylinder availability range

on the lens plane according to the respective IOL models

labelling. See examples in table below.

7. To add a new row after one was entered, you need to

overwrite the fields on top and press Add

8. Click ‘Close’

9. Click ‘Save’

Page 7: ZEISS IOLMaster 700

77

Alcon Acrysof® Toric SN6AT (2-9) (iolcon.org, 2019)

Alcon PanOptix® Toric (TFNT20-60) (iolcon.org, 2019)

SE range (D) SE increment (D) Cylinder format Cylinder (D) Label

+6.00 to +30.00 0.50 Single +1.00 T2

+31.00 to +34.00 1.00 Single +1.00 T2

+6.00 to +30.00 0.50 Single +1.50 T3

+31.00 to +34.00 1.00 Single +1.50 T3

+6.00 to +30.00 0.50 Single +2.25 T4

+31.00 to +34.00 1.00 Single +2.25 T4

+6.00 to +30.00 0.50 Single +3.00 T5

+31.00 to +34.00 1.00 Single +3.00 T5

+6.00 to +30.00 0.50 Single +3.75 T6

+31.00 to +34.00 1.00 Single +3.75 T6

+6.00 to +30.00 0.50 Single +4.50 T7

+31.00 to +34.00 1.00 Single +4.50 T7

+6.00 to +30.00 0.50 Single +5.25 T8

+31.00 to +34.00 1.00 Single +5.25 T8

+6.00 to +30.00 0.50 Single +6.00 T9

+31.00 to +34.00 1.00 Single +6.00 T9

SE range (D) SE increment (D) Cylinder format Cylinder (D) Label

+6.00 to +30.00 0.50 Single +1.00 20

+31.00 to +34.00 1.00 Single +1.00 20

+6.00 to +30.00 0.50 Single +1.50 30

+31.00 to +34.00 1.00 Single +1.50 30

+6.00 to +30.00 0.50 Single +2.25 40

+31.00 to +34.00 1.00 Single +2.25 40

+6.00 to +30.00 0.50 Single +3.00 50

+31.00 to +34.00 1.00 Single +3.00 50

+6.00 to +30.00 0.50 Single +3.75 60

+31.00 to +34.00 1.00 Single +3.75 60

Page 8: ZEISS IOLMaster 700

88

J&J TECNIS® Toric ZCT (100-800) (iolcon.org, 2019)

J&J TECNIS® Symfony® Toric (ZXT 100-600) (iolcon.org, 2019)

SE range (D) SE increment (D) Cylinder format Cylinder (D) Label

+5.00 to +34.00 0.50 Single +1.00 100

+5.00 to +34.00 0.50 Single +1.50 150

+5.00 to +34.00 0.50 Single +2.25 225

+5.00 to +34.00 0.50 Single +3.00 300

+5.00 to +34.00 0.50 Single +3.75 375

+5.00 to +34.00 0.50 Single +4.50 450

+5.00 to +34.00 0.50 Single +5.25 525

+5.00 to +34.00 0.50 Single +6.00 600

+5.00 to +34.00 0.50 Single +7.00 700

+5.00 to +34.00 0.50 Single +8.00 800

SE range (D) SE increment (D) Cylinder format Cylinder (D) Label

+5.00 to +34.00 0.50 Single +1.00 100

+5.00 to +34.00 0.50 Single +1.50 150

+5.00 to +34.00 0.50 Single +2.25 225

+5.00 to +34.00 0.50 Single +3.00 300

+5.00 to +34.00 0.50 Single +3.75 375

+5.00 to +34.00 0.50 Single +4.50 450

+5.00 to +34.00 0.50 Single +5.25 525

+5.00 to +34.00 0.50 Single +6.00 600

Hoya 351 Toric (T3-9) (hoyasurgicaloptics.com, 2019)

SE range (D) SE increment (D) Cylinder format Cylinder (D) Label

+10.00 to +30.00 0.50 Single +1.50 T3

+10.00 to +30.00 0.50 Single +2.25 T4

+10.00 to +30.00 0.50 Single +3.00 T5

+10.00 to +30.00 0.50 Single +3.75 T6

+10.00 to +30.00 0.50 Single +4.50 T7

+10.00 to +30.00 0.50 Single +5.25 T8

+10.00 to +30.00 0.50 Single +6.00 T9

Page 9: ZEISS IOLMaster 700

99

Hoya Vivinex™ XY1A Toric (T2-9) (hoyasurgicaloptics.com, 2019)

ZEISS AT LARA toric 929M/MP

SE range (D) SE increment (D) Cylinder format Cylinder (D) Label

+10.00 to +30.00 0.50 Single +1.00 T2

+10.00 to +30.00 0.50 Single +1.50 T3

+10.00 to +30.00 0.50 Single +2.25 T4

+10.00 to +30.00 0.50 Single +3.00 T5

+10.00 to +30.00 0.50 Single +3.75 T6

+10.00 to +30.00 0.50 Single +4.50 T7

+10.00 to +30.00 0.50 Single +5.25 T8

+10.00 to +30.00 0.50 Single +6.00 T9

Please contact your local ZEISS representative for entry of the ZEISS AT LARA toric 929 M/MP IOLs

into the ZEISS IOLMaster 700.

Page 10: ZEISS IOLMaster 700

1010

Note:

• Formula constants used in fi gures below are an example. The user is responsible for correct entry of IOL constants, power

steps and ranges according to each IOL.

• Please contact IOL manufacturer for optimized IOL formula constants or use your own personalized constants.

Adding Toric IOLs with Consistent CYL Power Steps

1. Enter the IOL information – i.e. Manufacturer, Name of

IOL, IOL constants, etc.

2. Select IOL parameter “Toric”

3. Choose if the IOL is delivered with Spherical Equivalent

Steps (SE) or with Spherical Steps (Sph) (In this example

Sph is chosen)

4. Click on ‘Delivery range…’

Page 11: ZEISS IOLMaster 700

1111

5. In the delivery range menu, delete the

pre-populated default settings (-100 to +100D)

by pressing the trashcan icon

6. For each row in the respective IOL’s table below: Enter

the SE range, SE increment, Cylinder format (Range),

Cylinder Range and Cylinder increment as well as label

and press Add

Note:

“Range” does not refer to astigmatism correction range on

the cornea plane. It refers to the cylinder availability range

on the lens plane according to the respective IOL models

labelling. See examples in table below.

7. To add a new row after one was entered, you need to

overwrite the fi elds on top and press Add

8. Click ‘Close’

9. Click ‘Save’

ZEISS AT LISA tri toric 939M/MP (zeiss.de, 2019)

SE range (D) SE increment Cylinder format Cylinder range Cylinder increment Label

-10.00 to +32.00 0.50 Range +1.00 to +12.00 0.5

Page 12: ZEISS IOLMaster 700

1212

hoyasurgicaloptics.com. (2019, January 07).

Retrieved from

Link

hoyasurgicaloptics.com. (2019, March 07).

Retrieved from

Link

iolcon.org. (2019, December 11).

Retrieved from

Link

iolcon.org. (2019, December 11).

Retrieved from

Link

iolcon.org (2019, December 01).

Retrieved from

Link

iolcon.org (2019, December 01).

Retrieved from

Link

zeiss.de. (2019, March 12).

Retrieved from

Link

References

Page 13: ZEISS IOLMaster 700

Carl Zeiss Meditec AGGoeschwitzer Strasse 51–5207745 JenaGermanywww.zeiss.com/iolmaster700

EN_

32_0

12_0

033I

CZ

-XII/

2019

In

tern

atio

nal e

ditio

n: O

nly

for s

ale

in s

elec

ted

coun

tries

.Th

e co

nten

ts o

f the

qui

ck g

uide

may

diff

er fr

om th

e cu

rrent

sta

tus

of a

ppro

val o

f the

pro

duct

or s

ervi

ce o

fferin

g in

you

r cou

ntry

. Ple

ase

cont

act o

ur re

gion

al re

pres

enta

tives

for m

ore

info

rmat

ion.

Su

bjec

t to

chan

ges

in d

esig

n an

d sc

ope

of d

eliv

ery

and

due

to o

ngoi

ng te

chni

cal d

evel

opm

ent.

IOLM

aste

r, AT

LAR

A an

d AT

LIS

A ar

e re

gist

ered

trad

emar

ks o

f Car

l Zei

ss M

edite

c AG

or o

ther

com

pani

es

of th

e ZE

ISS

Grou

p in

Ger

man

y an

d/or

oth

er c

ount

ries.

© C

arl Z

eiss

Med

itec

AG, 2

019.

All

right

s re

serv

ed.

0297