Cold-store and deep-freeze cells
Xxx
XxxZ xxx-xAs of: 00/00Page: 1
Cold-store and deep-freeze cells
Cold-store and deep-freeze cellZ 001-8As of: 02/20
2500
100 2300 100100
DIN rightF .....N .....
1810
1610
F ...
..N
.....
F ..... N .....
F ...
..N
.....
350
900/
1900
360
For example:
IH (interior height) 2060PH (partial height) 2080EH (exterior height) 2305
All dimensions to customer specification AA
Section view A-A
Cut parts
Upper door part
Corner post Complete wall element
Ceiling element100
100
2305
2060
Shelf
Ventilation section Floor panel145
Door
hei
ght 1
900
For example:
IH (interior height) 2060PH (partial height) 2080EH (exterior height) 2305
All dimensions to customer specification
327018101610
14601380100100 80
100
590
2270
2070
900
/ 19
00
100
580
A A
Deep cooling
Cooling
290 290800 / 1900
2110
2270
8080
100
100
160
160
2305
2060
1900
2060
2305
145
145
Section view A-A
Romakowski GmbH & Co. KG · Herdweg 31 · 86647 Buttenwiesen, GermanyPhone +49 (0) 8274.999-0 · Fax +49 (0) [email protected] · www.roma-kuehlzellen.de
Page: 2
Cold-store and deep-freeze cells
Combination cellZ 002-7As of: 02/20
3000
900/
1900
1350 1350100 100100
300
300
900/
1900
300
300
A A
100
1500
1700
100
Section view A-A
100
160
1900
2060
2305
145
Deep cooling
Cooling
For example:
IH (interior height) 2060PH (partial height) 2080EH (exterior height) 2305
All dimensions to customer specification
Romakowski GmbH & Co. KG · Herdweg 31 · 86647 Buttenwiesen, GermanyPhone +49 (0) 8274.999-0 · Fax +49 (0) [email protected] · www.roma-kuehlzellen.de
Page: 3
Cold-store and deep-freeze cells
Cell with partition wallZ 003-7As of: 02/20
Romakowski GmbH & Co. KG · Herdweg 31 · 86647 Buttenwiesen, GermanyPhone +49 (0) 8274.999-0 · Fax +49 (0) [email protected] · www.roma-kuehlzellen.de
Page: 4
Cold-store and deep-freeze cells
from 80 PU
Floor-wall and ceiling-wall connectionZ 006-9As of: 02/20
1
2
8
3
4
1
1
5
6
6
5
77
7
5
6
8
2
4
1
3
ROMA panel
Angle (optional)
Pressure distribution plate
Flooring
Outside corner angle
Foam spring
Ventilation profile
Silicone sealing
Romakowski GmbH & Co. KG · Herdweg 31 · 86647 Buttenwiesen, GermanyPhone +49 (0) 8274.999-0 · Fax +49 (0) [email protected] · www.roma-kuehlzellen.de
Page: 5
Cold-store and deep-freeze cells
Floor-wall connection Z 022-3As of: 02/20
for stainless steel floors
8
4
2
36
5
7
1
2
3
4
5
6
7
8
ROMA panel
Silicone sealing compound
Pressure distribution plate
Flooring
Outside corner angle
Foam spring
Ventilation section
Floor bracket stainless steel 1.5mm 33/70
1
Romakowski GmbH & Co. KG · Herdweg 31 · 86647 Buttenwiesen, GermanyPhone +49 (0) 8274.999-0 · Fax +49 (0) [email protected] · www.roma-kuehlzellen.de
Page: 6
Cold-store and deep-freeze cells
For cold-store cells without floor insulation
Floor connectionsZ 008-5As of: 02/20
1
2
3
2
4
X
Version withU-profiles
X = Angular heightPU = Panel thickness
PU
PU
Plastic-Ustandard (X)
Stainless-Ustandard (X)
Stainless-Uoption (X)
60 80 >100100
40 40
40 404040
60 80 100 100
PUVersion withangles
1
2
5
2
40
4
4
5
3
2
1 ROMA panel
Silicone sealing compound
Plastic- / stainless-U-profile
Doweled into floor
Aluminum- / stainless-angle
Romakowski GmbH & Co. KG · Herdweg 31 · 86647 Buttenwiesen, GermanyPhone +49 (0) 8274.999-0 · Fax +49 (0) [email protected] · www.roma-kuehlzellen.de
Page: 7
Cold-store and deep-freeze cells
PU 80 / 100 / 120 / 140
Door - corner placement (DEZI)Z 004-2As of: 02/20
3
100/
140
60
Corner placement with spring side
Corner placement with groove side
Door leaf
95
PU 80
PU 100/120/140
95
50 50
1
3
2
95 95
50 50
1
1
2
2
3
PU 170/200
95 95
50 50
1
3
140
2
3
2
1 Corner placement / panel part with spring side
Corner placement / panel part with groove side
Door leaf
Romakowski GmbH & Co. KG · Herdweg 31 · 86647 Buttenwiesen, GermanyPhone +49 (0) 8274.999-0 · Fax +49 (0) [email protected] · www.roma-kuehlzellen.de
Page: 8
Cold-store and deep-freeze cells
Door - corner placement (DEZI)Z 013-1As of: 02/20
PU 170 / 200
Romakowski GmbH & Co. KG · Herdweg 31 · 86647 Buttenwiesen, GermanyPhone +49 (0) 8274.999-0 · Fax +49 (0) [email protected] · www.roma-kuehlzellen.de
Page: 9
Cold-store and deep-freeze cells
Floor construction aluminum checker plateZ 010-8As of: 02/20
slip resistance R10
Lap without joint withbatu sealing underlaid
Aluminum checker plate, R10laid with offset joints
Pressure distribution plate
Senko V2A tappingscrew 4.8 x 45PU floor panel
Ventilation sectiond
a Dh
PU
25
60
b
Aluminum checker plate
R10
Wheel load (N) N/cm² h d/D a b Floor Nr.
1000
2000
3500
5000
250
500
875
1250
PU + 45
PU + 47
PU + 49
PU + 55
2/2.5
2.5/4
3.5/5
3.5/5
18
18
19
25
approx. 450
approx. 450
approx. 300
approx. 200
1
2
3
4
Floor-wall connection with siliconeFloors can only be driven on using rubber wheels at least ø 200mmMaximum load: approx 40 kN/m² with evenly distributed load
500
875
1250
PU + 52
PU + 59
PU + 72
9
9
9
18
25
38*
approx. 450
approx. 300
approx. 200
8
9
10
RomanitR11
Floor-wall connection with Aluminum bracket anodized 2mm 40 x 40Floors can only be driven on using rubber wheels at least ø 200mmMaximum load: approx 40kN/m² with evenly distributed load*Senko 4.8 x 60 for a = 38mm
Hit with silicone
Reinforced floor
Romanit, R11laid with offset joints
PU floor panel
Ventilation section
Senko V2A tapping screw 4.8 x 45 (60*)
60
25
PU
b
Da
h
Wheel load (N) N/cm² D a Floor Nr.h b
2000
3500
5000
Pressure distribution plate
Romakowski GmbH & Co. KG · Herdweg 31 · 86647 Buttenwiesen, GermanyPhone +49 (0) 8274.999-0 · Fax +49 (0) [email protected] · www.roma-kuehlzellen.de
Page: 10
Cold-store and deep-freeze cells
Floor construction RomanitZ 012-8As of: 02/20
slip resistance R11
V2A TRI, R11 optional R12 or R13laid with offset joints
25
60
b
PU
h
aD
Wheel load (N) N/cm² D Floor Nr.h a bStainless steel TRI
R11 2000
3500
500
875
PU + 45
PU + 52
2
2 25
18 approx. 400
approx. 300
27
28
Floor-wall connection with stainless steel bracket 1.5mm 70 x 33Floors can only be driven on using rubber wheels at least ø 200mmMaximum load: approx 40 kN/m² with evenly distributed load
Senko V2A tappingscrew 4.8 x 45
Reinforced floor
Pressure distribution plate
PU floor panel
Ventilation section
Lap without joint withbatu sealing underlaid
Romakowski GmbH & Co. KG · Herdweg 31 · 86647 Buttenwiesen, GermanyPhone +49 (0) 8274.999-0 · Fax +49 (0) [email protected] · www.roma-kuehlzellen.de
Page: 11
Cold-store and deep-freeze cells
Floor construction stainless steel TRI 1.4301Z 024-4As of: 02/20
slip resistance R11, optional R12 or R13
Reinforced floor
Stainless steel Mandorla, R12laid with offset joints
25
b
60D
da
hPU
Stainless steelMandorla
R12
Wheel load (N) N/cm² h d/D a b Floor Nr.
5000
10000
1250
2500
PU + 55
PU + 68
3/5
3/5
25
38*
approx. 200
approx. 200
19
20
Floor-wall connection with stainless steel bracket 1.5mm 70 x 33Floors can only be driven on using rubber wheels at least ø 200mmMaximum load: approx. 40 kN/m² with evenly distributed load*Senko 4.8 x 60 for a = 38mm
Lap without joint withbatu sealing underlaid
PU floor panelSenko V2A tappingscrew 4.8 x 45 (60*)
Ventilation section
Romakowski GmbH & Co. KG · Herdweg 31 · 86647 Buttenwiesen, GermanyPhone +49 (0) 8274.999-0 · Fax +49 (0) [email protected] · www.roma-kuehlzellen.de
Page: 12
Cold-store and deep-freeze cells
Floor construction stainless steel Mandorla 1.4301Z 017-7As of: 02/20
slip resistance R12
V2A TRI, R11laid with offset joints
Glued joints
Cord + Silicone
Welded corners
7/8
40
Ventilation section
25
60
b
PUD
a
h
Stainless steel TRIR11
Wheel load (N) N/cm² h D a b Floor Nr.
2000
3500
500
875
PU + 45
PU + 52 2
2 18
25
approx. 400
approx. 300
95
70
Floors can only be driven on using rubber wheels at least ø 200mmMaximum load: approx. 40 kN/m² with evenly distributed load
Senko V2A tappingscrew 4.8 x 45
Pressure distribution plate
PU floor panel
Reinforced flooredged up
Romakowski GmbH & Co. KG · Herdweg 31 · 86647 Buttenwiesen, GermanyPhone +49 (0) 8274.999-0 · Fax +49 (0) [email protected] · www.roma-kuehlzellen.de
Page: 13
Cold-store and deep-freeze cells
Floor construction stainless steel TRI 1.4301Z 018-1As of: 02/20
welded corners - slip resistance R11
Lap without joint
Batu sealing strip
Floor constructionsee previous pageslaid with offset joints
Vacuum floor panelV2A tapping screw
PS (Polystyrene)Vacuum pads lathered in panel
ROMAinsulation thickness
h
10a
d
D
U-value on request
Maximum load: 40 kN/m² with evenly distributed load
h = Floor construction at least 90mm
Romakowski GmbH & Co. KG · Herdweg 31 · 86647 Buttenwiesen, GermanyPhone +49 (0) 8274.999-0 · Fax +49 (0) [email protected] · www.roma-kuehlzellen.de
Page: 14
Cold-store and deep-freeze cells
Floor construction with vacuum floorZ 023-3As of: 02/20
80
73
1500
80
40
Romakowski GmbH & Co. KG · Herdweg 31 · 86647 Buttenwiesen, GermanyPhone +49 (0) 8274.999-0 · Fax +49 (0) [email protected] · www.roma-kuehlzellen.de
Page: 15
Cold-store and deep-freeze cells
Remote thermometer with sensorZ 021-4As of: 02/20
Ramp width =Clearance width door + (Surcharge)
Ram
p le
ngth
Floo
r hei
ght x
10
(max
. 123
0)
Floor heightExecutions:3.0/4.5mm V2A Mandorla, R12 1000kg/Wheel load2.0mm V2A TRI, R11 400kg/Wheel load3.5/5.0mm Checker aluminum plate, R10 500kg/Wheel load2.5/4.0mm Checker aluminum plate, R10 200kg/Wheel load
Birch 24mm
CoverRAL 9010
Solid spruce unit spacing approx. 150mm
Floo
r hig
htm
in. 2
6mm
max
. 250
mm
Romakowski GmbH & Co. KG · Herdweg 31 · 86647 Buttenwiesen, GermanyPhone +49 (0) 8274.999-0 · Fax +49 (0) [email protected] · www.roma-kuehlzellen.de
Page: 16
Cold-store and deep-freeze cells
Standard ramp designZ 029-2As of: 02/20
Pressure equalization size 1 up to 162m³Pressure equalization size 2 up to 440m³ (option ceiling installation)Pressure equalization size 3 up to 5975m³
Section view A-A Section view B-B
PU Heating cable
cold warm coldwarm
Exhaust air Supply air
B A
B A
Holes
Size 1 ø 95mm Size 2 ø 120mmSize 3 ø 315mm
Size
3
4
00 /
400
Size
2
1
40 /
140
Size
1
1
11 /
111
Romakowski GmbH & Co. KG · Herdweg 31 · 86647 Buttenwiesen, GermanyPhone +49 (0) 8274.999-0 · Fax +49 (0) [email protected] · www.roma-kuehlzellen.de
Page: 17
Cold-store and deep-freeze cells
Size 1, 2 and 3
Pressure equalization Hemstedt Z 030-1As of: 02/20