Johnson Controls 1 A chiller as unique as your needs. YORK Model YVAA Air-Cooled Chillers Variable Speed Screw, 150-500tons

YORK YVAA Air Cooled VSD Chiller Presentation Part 1

  • Upload
    iga9481

  • View
    616

  • Download
    50

Embed Size (px)

Citation preview

Page 1: YORK YVAA Air Cooled VSD Chiller Presentation Part 1

Johnson Controls1

A chiller as unique as your needs.

YORK Model YVAA Air-Cooled ChillersVariable Speed Screw, 150-500tons

Page 2: YORK YVAA Air Cooled VSD Chiller Presentation Part 1

Customer Value Proposition Duration: 20 minutes

Technology Duration: 20 minutes

CompetitionDuration: 20 minutes

Selling ToolsDuration: 20 minutes

Handling Customer NeedsDuration: 20 minutes

Questions and AnswersDuration: 20 minutes

Contents

Page 3: YORK YVAA Air Cooled VSD Chiller Presentation Part 1

Johnson Controls3

Value Proposition Duration: 20 minutes

Page 4: YORK YVAA Air Cooled VSD Chiller Presentation Part 1

YVAA – YORK Variable Speed Air-Cooled Screw Chillers

YORK – A History of Leadership and Innovation

4

The global market leader in Variable Speed Drive chillerswith 30 years of experience varying compressor motor speeds

Page 5: YORK YVAA Air Cooled VSD Chiller Presentation Part 1

YVAA – YORK Variable Speed Air-Cooled Screw Chillers

Key Benefits

5

Efficiency Sustainability Low Sound Confidence

Page 6: YORK YVAA Air Cooled VSD Chiller Presentation Part 1

6

Model YVAA – YORK Variable Speed Air-Cooled Screw Chillers

Overview

A Chiller As Unique As Your Needs

Tailor and tune chiller configuration to specific job requirements

Match performance to your design point

An industry leader in efficiencyand technology

Page 7: YORK YVAA Air Cooled VSD Chiller Presentation Part 1

7

Model YVAA – YORK Variable Speed Air-Cooled Screw Chillers

Overview

Key technology elements of the system

Heat Exchangers – high efficiency falling-film evaporator & advanced microchannel condenser coil designs

Controls – leveraging YORK and Johnson Controls technology & ‘know-how’

Variable Speed Drive – compressor VSD from the industry pioneer, and condenser fan VSD to maximize performance

Screw Compressors – proven, industry-leading screw compressor design with more than 15,000 VSD compressors operating worldwide

Page 8: YORK YVAA Air Cooled VSD Chiller Presentation Part 1

Efficiency

Intelligent cost reduction,flexible energy consumption

Page 9: YORK YVAA Air Cooled VSD Chiller Presentation Part 1

Industry’s Lowest EnergyConsumption at Design Conditions

When desired, YVAA chillers canbe offered at up to 11.6 EER

20% Improvement over currentASHRAE 90.1 minimum

Industry’s Lowest EnergyConsumption at Off-design Conditions

When desired YVAA chillers canbe offered up to 19.8 IPLV EER

Johnson Controls9

EfficiencyIntelligent cost reduction, flexible energy consumption

Ordinary Chiller

YVAA

Page 10: YORK YVAA Air Cooled VSD Chiller Presentation Part 1

YVAA chiller saves 25% to 50% in annual energy costs

For new or replacement installations, the YVAA offers significant savings

Johnson Controls10

EfficiencyIntelligent cost reduction, flexible energy consumption

Page 11: YORK YVAA Air Cooled VSD Chiller Presentation Part 1

Easily qualify for rebatesbased on VSD usage

Standard high power factorcan earn rebate withoutadded cost

Tailor & tune your YVAAchiller to qualify for anyPerformance Rebate

Johnson Controls11

EfficiencyIntelligent cost reduction, flexible energy consumption

Page 12: YORK YVAA Air Cooled VSD Chiller Presentation Part 1

Sustainability

Giant step forward,smaller footprint

Page 13: YORK YVAA Air Cooled VSD Chiller Presentation Part 1

Indirect Emissions Contribute 98% of Chiller GWP Electricity generation is the largest source

of greenhouse gas emissions

Efficiency of YVAA chiller offers substantial reductionin power consumption & your environmental footprint

Johnson Controls13

SustainabilityGiant step forward, smaller footprint

Direct Emissions Contribute 2% of Chiller GWP HFC-134a refrigerant has ZERO ozone-depletion potential

and no phase-out date

Falling-film evaporator reduces refrigerant charge by up to 15%

Water Consumption Power generation can deplete water resources

An indirect benefit of the YVAA chiller: water conservation

Gain the efficiency of a water-cooled chiller for the costof an air-cooled

Page 14: YORK YVAA Air Cooled VSD Chiller Presentation Part 1

Helps You Achieve LEED® Certification

Enhanced Refrigerant Management:Low refrigerant use ensures 2 points for Energy and Atmosphere Credit 4 (EAc4)

Optimize Energy Performance:Higher efficiency helps your building qualify for maximum pointsfor the Energy and Atmosphere Credit 1 (EAc1)

Johnson Controls14

SustainabilityGiant step forward, smaller footprint

Page 15: YORK YVAA Air Cooled VSD Chiller Presentation Part 1

Low Sound

Lower the volume, increase goodwill

Page 16: YORK YVAA Air Cooled VSD Chiller Presentation Part 1

Off-Design Conditions Occur 99% of the Time

Most stringent sound requirementsoccur on evenings and weekends

Standard VSD compressorsdesigned for sound relief areduced speeds

Optional VSD condenser fanswill provide further significantoff-design sound benefit

Further accessories can providesound reduction at on-designconditions

Johnson Controls16

Low SoundLower the volume, increase goodwill

YVAA

YVAA Optimized

YVAA Optimized with Attenuation Options

Ordinary Chiller

Page 17: YORK YVAA Air Cooled VSD Chiller Presentation Part 1

Sound Level That You Can Control

Our proprietary SilentNighttechnology automatically integrateswith your BAS (or programmable)control to load shed

BAS of load shedding provides“Night Set-Back’ for the neighborhood

Effective when regulationsrequire more stringent propertyline sound levels at night

Johnson Controls17

Low SoundLower the volume, increase goodwill

YVAA

YVAA Optimized

YVAA Optimized with Attenuation Options

Ordinary Chiller

-10

Page 18: YORK YVAA Air Cooled VSD Chiller Presentation Part 1

For the Other 1% at Design Conditions:

Property line restrictions will require attention to (worst case) design conditionssound levels

Just like performance, the YVAA chiller allows you to tailor and tune sound reduction configurations to match your needs

Johnson Controls18

Low SoundLower the volume, increase goodwill

Page 19: YORK YVAA Air Cooled VSD Chiller Presentation Part 1

Confidence

Confidence-driven,performance-proven

Page 20: YORK YVAA Air Cooled VSD Chiller Presentation Part 1

Proven by Experience

Over 2 Million tons of VSD, air-cooled screw chillers operating globally

All units combined, more than 18,000 years of cumulative field experience

ConfidenceConfidence-driven, performance-proven

Capacity:In Tons

> 50,000

10,000 – 50,000

5,000 – 10,000

1 – 5,000

Page 21: YORK YVAA Air Cooled VSD Chiller Presentation Part 1

Johnson Controls21

Compressor & VSD

More than 15,000 compressors operating on VSD in air-cooled chiller applications

Eliminates slide valve and associated inefficiencies, and reduces compressor moving parts by 50%

ConfidenceConfidence-driven, performance-proven

Reliable by Design

1 Circuit per compressor –built-in redundancy

Soft start standardno current inrush

Page 22: YORK YVAA Air Cooled VSD Chiller Presentation Part 1

Johnson Controls22

Proven Support

15,000+ Service Technicians(trucks on road) in 150 countries

Service Technicians trained onVSD screws since 2004

Bringing decades of VSD experience to your door

ConfidenceConfidence-driven, performance-proven

Page 23: YORK YVAA Air Cooled VSD Chiller Presentation Part 1

YVAA – YORK Variable Speed Air-Cooled Screw Chillers

Key Benefits

23

Efficiency Sustainability Low Sound Confidence

Page 24: YORK YVAA Air Cooled VSD Chiller Presentation Part 1

YVAA – YORK Variable Speed Air-Cooled Screw Chillers

24

Smart, sustainable, silent and specified the world over.

Reduce your annual energy costs by as much as 50%

Reduce your sound by up to 16dBA to meet tighter regulations

Minimize your environmental impact dramatically

Improve your peace of mind knowing we stand behind every chiller

Page 25: YORK YVAA Air Cooled VSD Chiller Presentation Part 1

Johnson Controls25

Technology Duration: 20 minutes

Page 26: YORK YVAA Air Cooled VSD Chiller Presentation Part 1

Johnson Controls26

YVAA Cycle Diagram

Page 27: YORK YVAA Air Cooled VSD Chiller Presentation Part 1

Johnson Controls27

YVAA Cycle Diagram

Page 28: YORK YVAA Air Cooled VSD Chiller Presentation Part 1

Johnson Controls28

YVAA Cycle Diagram

Page 29: YORK YVAA Air Cooled VSD Chiller Presentation Part 1

Lower sound at part load Higher efficiency at part load

Johnson Controls29

Ordinary ChillerYVAA

Variable Speed DriveDelivering best in class performance at real world conditions

YVAAYVAA OptimizedYVAA Optimized with Attenuation Options

Ordinary Chiller

-10

Page 30: YORK YVAA Air Cooled VSD Chiller Presentation Part 1

Johnson Controls30

VSD provides Soft start with no inrush: Starting current never exceeds full load amps.

Lowest maximum electricity demand costs Eliminates compressor starting thermal and

electrical stress No motor heating at start allows for quicker re-

start after power failure Stand by generator size reduced High (95%) displacement power factor

The VSD in YVAA provides 0.95 displacement power factor as standard.

Qualifies for rebates from electrical utility companies, which contributes to payback.

Variable Speed DriveImproves payback with lower electrical costs and rebates

Page 31: YORK YVAA Air Cooled VSD Chiller Presentation Part 1

Johnson Controls31

Variable Speed CompressorReliability through simplicity

Proven reliable compressor

52% fewer moving parts 35% fewer leak points

Automated machining of rotors

High precision ±4 microns Frick design and manufacture

Page 32: YORK YVAA Air Cooled VSD Chiller Presentation Part 1

DX Evaporator:

Water outside the tubes Refrigerant inside the tubes Water connection at sides

Johnson Controls32

Evaporator Technology

Flooded Evaporator:

Water inside the tubes Refrigerant outside the tubes Water connection at ends

Page 33: YORK YVAA Air Cooled VSD Chiller Presentation Part 1

Johnson Controls33

Falling Film EvaporatorIncorporates best elements of the DX and Flooded styles

Hybrid Falling Film Evaporator: Water is inside the tubes; Refrigerant is outside the tubes Two bundles of water tubes

Upper bundle is covered in a film of refrigerant Lower bundle is flooded in the refrigerant

Page 34: YORK YVAA Air Cooled VSD Chiller Presentation Part 1

Johnson Controls34

Micro Channel Condenser CoilsLightweight, robust and easily cleaned

Images courtesy

All Aluminum tubes, fins, and headers Better heat transfer per volume of coil

Page 35: YORK YVAA Air Cooled VSD Chiller Presentation Part 1

Johnson Controls35

Lighter weight of aluminum lowers the overall chiller weight: Save costs of roof reinforcements and lifting equipment

Reduces the amount of refrigerant used. The quantity of R134a used in the chiller allows to qualify for 2 LEED EAc4 points

Micro Channel Condenser CoilsLightweight, robust and easily cleaned

Page 36: YORK YVAA Air Cooled VSD Chiller Presentation Part 1

Johnson Controls36

All aluminum construction minimizes the opportunity for galvanic (dissimilar metal corrosion

Increases the chiller life and limits the degradation of performance over time The fins do not extend past the tubes making it easier to clean with water spray

without bending the fins. Microchannel coils are less deep, allowing complete washing without dirt being

trapped inside the coils

Micro Channel Condenser CoilsLightweight, robust and easily cleaned

Page 37: YORK YVAA Air Cooled VSD Chiller Presentation Part 1

Johnson Controls37

CompetitionDuration: 20 minutes

Page 38: YORK YVAA Air Cooled VSD Chiller Presentation Part 1

Most efficient air-cooled screw chiller in market Comparison at Full Load

Johnson Controls38

Efficiency levels 5% to 20% higher than ASHRAE 90.1 2010

Models up to 14% more efficient than market average at full loads

Standard Efficiency

High Efficiency

Premium Efficiency

Page 39: YORK YVAA Air Cooled VSD Chiller Presentation Part 1

Most efficient air-cooled screw chiller in market Comparison at Part Load

Efficiency levels 35% to 55% higher than ASHRAE 90.1 2010

Models up to 33% more efficient than market average at part loads

Johnson Controls39

YVAA Range

Staged Fans data to be added

Page 40: YORK YVAA Air Cooled VSD Chiller Presentation Part 1

Lowest MCA in marketMCA: Minimum Circuit Ampacity

Lower electrical costs

For replacement opportunities, allows to increase capacity without forcing to upsize the existing electrical connections

Johnson Controls40

YVAA Range