21
XXVI Workshop on Recent Developments in High Energy Physics and Cosmology Theodoros Argyropoulos NTUA DCS group Ancient Olympia 2008 ATLAS Cathode Strip Chambers Control System

XXVI Workshop on Recent Developments in High Energy Physics and Cosmology

  • Upload
    ramona

  • View
    35

  • Download
    1

Embed Size (px)

DESCRIPTION

ATLAS Cathode Strip Chambers. Control System. Theodoros Argyropoulos NTUA DCS group Ancient Olympia 2008. XXVI Workshop on Recent Developments in High Energy Physics and Cosmology. Outlook. CSC Geographical Position Tools CSC Control System Conclusions. - PowerPoint PPT Presentation

Citation preview

Page 1: XXVI Workshop on Recent Developments in    High Energy Physics and Cosmology

XXVI Workshop on Recent Developments in

High Energy Physics and Cosmology

Theodoros Argyropoulos NTUA DCS group Ancient Olympia 2008

ATLAS Cathode Strip Chambers

Control System

Page 2: XXVI Workshop on Recent Developments in    High Energy Physics and Cosmology

HEP 2008, Ancient Olympia

2

Outlook

CSC Geographical Position

Tools

CSC Control System

Conclusions

PVSS

FSM

FSM Architecture

Presentation of the user interfaces

19/4/2008

Page 3: XXVI Workshop on Recent Developments in    High Energy Physics and Cosmology

HEP 2008, Ancient Olympia

3

Cathode Strip Chambers (CSCs) are placed in the small endcaps of the ATLAS muonspectrometer.

High values of pseudorapidity, |η|>2.

CSC Geographical Position

19/4/2008

Page 4: XXVI Workshop on Recent Developments in    High Energy Physics and Cosmology

HEP 2008, Ancient Olympia

4

CSC Chambers

19/4/2008

Page 5: XXVI Workshop on Recent Developments in    High Energy Physics and Cosmology

HEP 2008, Ancient Olympia

5

Tools

1. PVSS provides tools to Graphic User Interface, archive... (basically monitoring and controlling the hardware)

2. SMI++ tools are used to model Devices and sub-system behaviour and to automate their operations.

19/4/2008

Page 6: XXVI Workshop on Recent Developments in    High Energy Physics and Cosmology

HEP 2008, Ancient Olympia

6

• PVSS II is a SCADA system. • SCADA stands for Supervisory Control And Data Acquisition. • PVSS is used to connect to hardware (or software) devices, acquire the data they produce and use it for their supervision, i.e. to monitor their behavior and to initialize, configure and operate them.

• A PVSS II system consists of function- specific managers known as managers.

PVSS II

19/4/2008

Page 7: XXVI Workshop on Recent Developments in    High Energy Physics and Cosmology

HEP 2008, Ancient Olympia

7

…PVSS II

• With PVSS II it is also possible to Interconnect a number of autonomous systems into an overall system.

• This is the way that the DCS system of the ATLAS experiment works.

• CSC sub-detector is one of these subsystems.

19/4/2008

Page 8: XXVI Workshop on Recent Developments in    High Energy Physics and Cosmology

HEP 2008, Ancient Olympia

8

Finite State Machines (FSM)

To reduce the number of parameters exported and managed in the supervisory layer;

To give a certain level of automation at complex Detector Control System;

19/4/2008

Page 9: XXVI Workshop on Recent Developments in    High Energy Physics and Cosmology

HEP 2008, Ancient Olympia

9

...Finite State Machines (FSM)

• STATE: defines the “operational mode of the system”

•STATUS: gives more details about “how well the system is working”.

The “STATE” and “STATUS” are two aspects that work in parallel and provide all necessary information about the behaviour of any system at any level in the hierarchy.

The STATUS is useful to find out faster the information when an error occurs.

In ATLAS the STATUS names are fixed.

19/4/2008

Page 10: XXVI Workshop on Recent Developments in    High Energy Physics and Cosmology

10 CSC Control System

Page 11: XXVI Workshop on Recent Developments in    High Energy Physics and Cosmology

11

FSM Architecture

Full local operation of sub detector (divided according to DAQ partition)

Overall operation of the detector, control of all sub detectors.

Not yet implemented

HEP 2008, Ancient Olympia

19/4/2008

Page 12: XXVI Workshop on Recent Developments in    High Energy Physics and Cosmology

HEP 2008, Ancient Olympia

12

User Interface

With the use of PVSS, there was created some expert panels for:

The User Interfaces for the people to work with

Storing data in the Data Base

Creating the Alarm text/status for the devices that are being used

19/4/2008

Page 13: XXVI Workshop on Recent Developments in    High Energy Physics and Cosmology

13

User Interface – Main Node

State Status

Take actions

Alarm Table

Main Panel

Secondary Panel

Commands

Status & Alarms

Overview ofthe PS and theTemps of the side

PS and Temps Alarms

HEP 2008, Ancient Olympia 19/4/2008

Page 14: XXVI Workshop on Recent Developments in    High Energy Physics and Cosmology

HEP 2008, Ancient Olympia

14

Power Supply - Hardware

For the High Voltage we use: 1 SY1527 CAEN Mainframe

1 CAEN BranchController A1676

2 CAEN EasyCrates

12 CAEN EasyBoards of type A3540P

19/4/2008

Page 15: XXVI Workshop on Recent Developments in    High Energy Physics and Cosmology

HEP 2008, Ancient Olympia

15

Power Supply - Hardware

For the Low Voltage we use: 6 Wiener Maraton power supplies

3 Remote Control Modules (RCM)

19/4/2008

Page 16: XXVI Workshop on Recent Developments in    High Energy Physics and Cosmology

16

Power Supply – User Interface

High VoltageState/Status

Low VoltageState/Status

Voltage & Current Histograms

Move Down to the chamber level

HEP 2008, Ancient Olympia

19/4/2008

Page 17: XXVI Workshop on Recent Developments in    High Energy Physics and Cosmology

17

Power Supply – User Interface

Voltage & Currentplots for all the channels

Voltage & Current Actual Values

Voltage & Current Settings

More Down

HEP 2008, Ancient Olympia

19/4/2008

Page 18: XXVI Workshop on Recent Developments in    High Energy Physics and Cosmology

18

Power Supply – User Interface

Voltage & Current Plots

Channel DetailsChannel Mapping

Switch Channel On & Off

Change Channel Settings

Configure the new Settings

HEP 2008, Ancient Olympia

19/4/2008

Page 19: XXVI Workshop on Recent Developments in    High Energy Physics and Cosmology

19

Temperatures – User Interface

TemperaturesState/Status

Low VoltageState/Status

Temperature Histogram

Change mode to HV PS

Down to the Chamber Level

HEP 2008, Ancient Olympia

19/4/2008

Page 20: XXVI Workshop on Recent Developments in    High Energy Physics and Cosmology

20

Temperatures – User Interface

Temps & LVState/Status

Value & Alarm text

Temperature Plot

HEP 2008, Ancient Olympia

If the temperature of a Sensor exceeds the limit of 35 degreesall the channels of the chamber are switched off.

19/4/2008

Page 21: XXVI Workshop on Recent Developments in    High Energy Physics and Cosmology

HEP 2008, Ancient Olympia

21

Conclusions

The System is installed as a Local Control System

Was tested by the CSC people and works.

Integrate it in the Muons Control System

Expand it to monitor the Gas and the Cooling System

19/4/2008