15
XP-8 RTI Advanced System Control Processor

XP-8 RTI Advanced System Control Processor

  • Upload
    geneva

  • View
    34

  • Download
    0

Embed Size (px)

DESCRIPTION

XP-8 RTI Advanced System Control Processor. Key Features: -(8) MPIO (Multi-purpose Input Output) ports -(8) Bi-directional RS-232 ports -(8) Sense inputs -(8) Programmable relay/voltage trigger outputs -Real time astronomical clock for time, day of week, - PowerPoint PPT Presentation

Citation preview

Page 1: XP-8 RTI Advanced System Control Processor

XP-8

RTI Advanced System ControlProcessor

Page 2: XP-8 RTI Advanced System Control Processor

Key Features:

-(8) MPIO (Multi-purpose Input Output) ports

-(8) Bi-directional RS-232 ports

-(8) Sense inputs

-(8) Programmable relay/voltage trigger outputs

-Real time astronomical clock for time, day of week, and interval based functions

-Rack mountable

-Non volatile Flash memory

Page 3: XP-8 RTI Advanced System Control Processor

SD/MM Memory Card Slot

Reset Button Menu Button

Cursor Control Buttons

IR Output Adjustment Controls Display Backlight Button

USB Programming Port

Page 4: XP-8 RTI Advanced System Control Processor

Bi-directional RS-232 Ports Sense Inputs

Relay/Trigger Outputs USB RTI COM Port

MPIO Ports (IR out, RS-232, Sync in) IR Connections

Ethernet Expansion Port

Page 5: XP-8 RTI Advanced System Control Processor

MPIO’s (Multi Purpose Input/Output ports)

-Each MPIO can directly drive up to 4 IR Emitters-Direct injection of IR to rear panel of devices-Use with Video Sync or Voltage Sense modules-Use for RS-232 communication with CM-232 module

Page 6: XP-8 RTI Advanced System Control Processor

RS-232 Ports

-Category 5 with RJ-45 termination (568b)-(8) RJ-45 to DB-9 adapters included-Bi-directional RS-232 capable

Page 7: XP-8 RTI Advanced System Control Processor

Sense Inputs

-Sense contact closure-Sense voltage trigger-Upon sensing, events can be automatically triggered from the XP-8

Page 8: XP-8 RTI Advanced System Control Processor

Relay/Trigger Outputs

-Configure as contact closure or voltage trigger-5 or 12 +VDC, 100mA current capability-Normally open or normally closed-When configured as a trigger, A= +VDC, B= GROUND

Page 9: XP-8 RTI Advanced System Control Processor

Infrared Terminals

-Terminal: +12VDCUsed to power external IR or RF receivers

-Terminal: GNDGround reference for any device connected to any terminal (SIGNAL IN, +12VDC, HIGH OUT)

-Terminal: SIGNAL INIR or RF system trigger code input

-Terminal: HIGH OUT200mA IR output to power an external connecting block or IR blaster

Page 10: XP-8 RTI Advanced System Control Processor

Ethernet Port

RJ-45 port allows connection to LAN to download systemfiles to the XP-8

USB Ports (rear)

Host ports for external devices (future use)

Page 11: XP-8 RTI Advanced System Control Processor

RTI COM Port

RJ-45 port allows connection to a Zigbee transceiver (ZM-24) module, supporting full two-way communicationwith compatible RTI handheld controllers

Expansion Port

RJ-45 port provides a connection for IR signals for a CB-4connecting block, or RS-485 serial communication within-wall controllers, or expansion devices like the RCM-12

Page 12: XP-8 RTI Advanced System Control Processor

MENU -Delivers the main menu if unlocked, the unlock screen if XP-8 is locked

SEL -Selects menu/function

EXIT -Navigate back 1 level (function to menu, or menu to previous menu)

CURSOR Keys -Navigate the selected menu options

Page 13: XP-8 RTI Advanced System Control Processor

Display

- Sensing status of VPS-1/SPS-1 power sync modules- Status of each “Sense” input- Current state (open, closed) of each relay- Current firmware date/version- Time/date- On-screen diagnostics

Page 14: XP-8 RTI Advanced System Control Processor

XP-8 Processing Rules

-XP-8 will send standalone IR codes in the order they are received from the controllers

-6 macro engines allow for the execution of up to six macros simultaneously

-Once an IR command begins, it runs to completion

-If a macro sends an IR code, it will wait at that step until the IR generator is free

-Once a macro begins to transmit IR codes, that macro engine has exclusive use of the IR generator until it sends an instruction OTHER than IR (flag test, relay, delaying, etc.)

Page 15: XP-8 RTI Advanced System Control Processor