XENAX® comparison between Xvi 75V8 and Xvi 48V8
Translation of ‘’XENAX_Xvi75V8_Xvi48V8_Unterschiede‘‘
Edition December 2015 Compact Ethernet Servo Controller
Parameterization over Web browser
The integrated webserver a l lows a setup and parameter izat ion over web browser.
After an automatic se l f -check, the connected LINAX® l inear motor ax is or
ELAX® e lectr ic s l ide can instant ly be set in mot ion by c l ick on the Quickstart Button.
Those XENAX® Xvi 75V8 and Xvi48v8 are
sett ing new standards in terms of intu it ive handl ing .
vs
2
Contents
1 XENAX® Xvi 75V8 vs Xvi 48V8 3 1.1 Electronic / Firmware 3
1.2 Performance / Options 4
1.3 Controllable Motor-Types 5
1.4 Dimensions 6
1.5 Electrical connections 7
1.5.1 Plug Arrangement 7
2 Specific characteristics XENAX® Xvi 48V8 8 2.1 Electrical connections 8
2.1.1 PLC I/O 8
2.1.2 XENAX® Xvi 48V8 OPTIO Pulse/Dir, second encoder channel 9
2.2 Optional license code 10
2.2.1 Display the actual license code 10
2.2.2 Subsequent license ordering 10
2.2.3 License activation 10
2.3 WebMotion® HTML5 12
2.3.1 ASCII Command Set for XENAX® Xvi 48V8 12
2.3.2 Save / Open application 12
2.4 Error code for XENAX® Xvi 48V8 13
3
1 XENAX® Xvi 75V8 vs Xvi 48V8
1.1 Electronic / Firmware
Description Data Xvi 75V8 Data Xvi 48V8
Interfaces Ethernet, TCP/IP via Xport, http Web Server WebMotion® with Java Plug-in
Ethernet, TCP/IP, http Web Server WebMotion® with HTML5
Pulse /Direction, Master Encoder, I/O I2C Master/Slave, Start-up Key RS232
Pulse /Direction, Master Encoder, I/O I2C Master/Slave, Start-up Key RS232
Bus, Multi axis system EtherCAT (CoE), DS402 Ethernet POWERLINK, DS402 CANopen, DS402 PROFINET (PROFIdrive) EtherNet/IP, DS402 Ethernet Switch, TCP/IP
EtherCAT (CoE), DS402 Ethernet POWERLINK, DS402 CANopen, DS402 PROFINET (PROFIdrive) EtherNet/IP, DS402 Ethernet Switch, TCP/IP
Safety Motion Unit SMU Security module, 2-channel monitoring TÜV certified SIL 2 Safety Integrity Level 2 Cat 3 Category 3 PL d Performance Level d MTTFd 1733313 h
-
Displayed Status 7-Segment LED 7-Segment LED
IP Adress displayed: by switching off and on the power during the power up phase, when a point is displayed on the 7-Segment
Input digital 12 x 24V Pull down 4 x 24V Pull down
Input function 8 inputs to start a function or program 4 inputs to start a function or program
Output digital 8 x 24V, 100mA Source or 400mA Sink 2 x 24V, 300 mA Source
Output function 8 outputs to indicate a condition 2 outputs to indicate a condition
Homing of rotary motor free to define, incl. external sensor free to define, incl. external sensor
Indexes 50 motion profiles (acceleration / velocity / distance, position)
50 motion profiles (acceleration / velocity / distance, position)
Profiles 5 extended motion profiles with 7 profile segments each.
5 extended motion profiles with 7 profile segments each.
Number of application programs via input
8 program call over input’s function or 15 program call over Input 9-12 binary coded (MODE >=10)
4 program call over input’s function
Firmware update over TCP/IP, internal flash-memory over TCP/IP, internal flash-memory
Application and parameter update
over TCP/IP, internal flash-memory over TCP/IP, internal flash-memory
4
1.2 Performance / Options
Description Data Xvi 75V8 Data Xvi 48V8
„LG“ Logic supply 24 VDC / max. 1.3 A 24 VDC / max. 1.2 A
„PW“ power supply motor 12-75 VDC 12-48 VDC
3- Phases Output frequency 0-599 Hz 0-599 Hz
Nominal current 0-8 A 0-8 A
Peak current 18 A 18 A
Continuous power / dissipation loss
Typical 48 V / 3 A / 150 W / η ≈ 85% / Pv = 22 W
Typical 48 V / 3 A / 150 W / η ≈ 85% / Pv = 22 W
Temperature monitoring output stage
Shutdown at 80°C Shutdown at 80°C
Excess voltage – observation > 85 V > 60 V
Under voltage – observation < 10 V < 10 V
Ballast circuit Up to 80 W Up to 80 W
Fuse power 10 AF 10 AF
Motor temperature observation with
LINAX®/ELAX® linear motor, sensor in coils
Shutdown at 80°C Shutdown at 80°C
PLC Input 8 Inputs, 24 V 4 Inputs, 24 V
PLC Input BCD 4 Inputs, 24 V, binary coded for program selection
-
PLC Output 8 Outputs, 24 V, Source 100 mA, Sink 400 mA, Source/Sink
2 Outputs, 24 V, Source 300 mA
Options
Description Data Xvi 75V8 Data Xvi 48V8
EtherCAT (CoE) DS402, Beckhoff®, OMRON®, TRIO® MC, CodeSys, Kithara
DS402, Beckhoff®, OMRON®, TRIO® MC, CodeSys, Kithara
POWERLINK (CoP) DS402, B&R® DS402, B&R®
CANopen DS402, Schneider Electric DS402, Schneider Electric
EtherNet/IP DS402, Allen-Bradley DS402, Allen-Bradley
PROFINET (PROFIdrive) SIMATIC, SIMOTION, CodeSys SIMATIC, SIMOTION, CodeSys
SMU Safety Functions STO Safe Torque Off SS1 Safe Stop 1 SS2 Safe Stop 2 SLS Safely-Limited Speed
-
Start-up Key ID number for Master Slave and application memory
ID number for Master Slave and application memory
Force functionalities integrated Option with license code
5
1.3 Controllable Motor-Types
XENAX® Xvi 75V8 XENAX® Xvi 48V8
LINAX® Linear Motors
Option with license code
ELAX® Electric Slides with Linear Motor
Servo Motors in our Product Line
Lafert, RAxx, RTxx
Third part servo motors Faulhaber®, Maxon®
6
1.4 Dimensions
XENAX® Xvi 75V8
XENAX® Xvi 48V8
Xvi 75V8 Xvi 48V8
Dirt resistance
IP 20 IP 20
Weight
550 g 720 g
Weight with bus module
590 g 760 g
Case
Coated Chrome steel
Ground plate
Aluminum sand-blasted Chrome steel
28
14
0
Ø6.5
14
30
1
25
183
11
0
14
0
Ø6.5
15
12
5
159
11
0
7
1.5 Electrical connections
XENAX® Xvi 75V8
XENAX® Xvi 48V8
1.5.1 Plug Arrangement
Description
Plug type XENAX® Xvi 75V8 Plug type XENAX® Xvi 48V8
RS232 USB-B socket USB-B socket
Realtime Ethernet (optional)
2 x RJ45 socket with status LED 2 x RJ45 socket with status LED
CANopen (optional) 9 Pol socket D-Sub 9 Pol socket D-Sub
Ethernet TCP/IP RJ45 socket with status LED RJ45 socket with status LED
MOTOR 3 pole plug Wago, pitch 3,5mm 3 pole plug Wago, pitch 3,5mm
POWER / LOGIK 4 pole plug Wago, pitch 3,5mm 4 pole plug Wago, pitch 3,5mm
ENCODER HALL 15 pole plug D-Sub High Density 15 pole plug D-Sub High Density
OPTIO 8 pole socket RJ45 15 pole plug D-Sub High Density
PLC I/O 26 pole plug D-Sub High Density
START-UP / MASTER-SLAVE 2 x 4 pole plug USB-A 2 x 4 pole plug USB-A
OPTIO PLC Pin1
MOTOR
Pin1, 2 Logic
START-UP / Master-Slave
ENC HALL
Pin3, 4 Power
Optional: EtherCAT
Profinet Powerlink CANopen
EtherNet/IP RS232 Ethernet
TCP/IP
PLC and OPTIO
Pin1 MOTOR
Pin1, 2 Logic
START-UP / Master-Slave
ENC HALL
Pin3, 4 Power
Optional: EtherCAT
Profinet Powerlink CANopen
EtherNet/IP RS232 Ethernet
TCP/IP
8
2 Specific characteristics XENAX® Xvi 48V8
2.1 Electrical connections
2.1.1 PLC I/O
Output
Signal D-Sub PLC Cable Connector PLC I/O / Analog Source PNP: 24V / 300mA Pin 1 White Output 1 (0/24V) Source PNP: 24V / 300mA Pin 2 Brown Output 2 (0/24V)
Input
24V Input, Ri 31k Pin 3 Green Input 1
24V Input, Ri 31k Pin 4 Yellow Input 2
24V Input, Ri 31k Pin 5 Grey Input 3
24V Input, Ri 31k Pin 6 Pink Input 4
Enabling Power Stage
Activate the function with DIP-switch
DIP- switch OFF HW power stage enabling with 24V on Pin 9 Pin 9 Black Enable PWR / Input
DIP- switch ON
Input open or 0V = power stage blocked
Always enabling power stage, Pin 9 inactive
Power Output
2A Pin 10 Violet GND
24V / 200mA Pin 11 Grey pink + 24V Out
2.1.1.1 Internal I/O Circuit
INPUT 1-4
OUTPUT 1-2
ON
OFF
HIGH or LOW ACTIVITY programmable
INPUT 1-4 24V, Ri = 31kΩ
Output ImaxOut = 300mA
9
2.1.2 XENAX® Xvi 48V8 OPTIO Pulse/Dir, second encoder channel
As standard, the XENAX® Xvi48V8 is delivered
without hardware activation for the OPTIO Pulse/Dir and second encoder channel.
Optional the XENAX® Xvi48V8 could be ordered with this hardware activation.
PULSE / DIRECTION CONTROL Parameter’s setting: MODE 2 (Pulse / Dir)
INC PER PULSE
Signal D-Sub PLC cable Connector PLC I/O / Analog
GND internal Pin 7 blue GND Pull Up 2,7kΩ to 5V, differential input 26LS32 Pin 15 white-yellow PULSE Pull Up 2,7kΩ to 5V, differential input 26LS32 Pin 13 white-green DIRECTION
Middle level: Pull Up 2,7kΩ to 5V, Pull Down 2.2kΩ, differential input 26LS32
Pin 12 red-blue DIRECTION
Middle level: Pull Up 2,7kΩ to 5V, Pull Down 2.2kΩ, differential input 26LS32
Pin 14 brown-green PULSE*
Second ENCODER Parameter’s setting:
MODE 1 (electronic gearbox)
SYNCH RATIO 10 = 1:1
Signal D-Sub PLC cable Connector PLC I/O / Analog
GND internal Pin 7 blue GND 5V internal Pin 8 red 5V (Power encoder)
Pull Up 2,7kΩ to 5V, differential input 26LS32 Pin 15 white-yellow A Pull Up 2,7kΩ to 5V, differential input 26LS32 Pin 13 white-green B
Middle level: Pull Up 2,7kΩ to 5V, Pull Down 2.2kΩ, differential input 26LS32
Pin 12 red-blue B*
Middle level: Pull Up 2,7kΩ to 5V, Pull Down 2.2kΩ, differential input 26LS32
Pin 14 brown-green A*
10
2.2 Optional license code
2.2.1 Display the actual license code
The activated licenses are displayed, when the WebMotion® is starting.
Or under
WebMotion® Start-> Operation -> firmware -> version
2.2.2 Subsequent license ordering
The MAC-address must be send to Jenny Science for any subsequent license ordering,
WebMotion® Start-> Operation -> firmware -> version
Possible licenses: LINAX® Linear motor axis
Force processes (Force) LINAX® and Force processes
2.2.3 License activation
WebMotion® start
Click on firmware / update
11
Click on XENAX® -> License Code
Entry the new given (from Jenny science) license code, in the displayed windows.
Click on SET LICENSE CODE
WebMotion® is starting new and display the new activated license.
By wrong license code introduction, „No Additional Licenses“ would be displayed.
12
2.3 WebMotion® HTML5
2.3.1 ASCII Command Set for XENAX® Xvi 48V8
DESCRIPTION Short CMD PARAMETER
TCP/IP-address definition Example: EIP192.168.2.69
Ethernet TCP/IP address EIP 192.168.2.69 / ?
Sub net mask definition Example: ENM255.255.255.0
Ethernet TCP/IP sub net mask
ENM 255.255.255.0 / ?
Default gateway definition Example: EGW192.168.1.10
Ethernet TCP/IP gateway EGW 192.168.1.10 / ?
Port Number definition Example: EPRT10001
Ethernet TCP/IP port EPRT 10001 / ?
Restore the factory settings for the Ethernet TCP/IP IP Adresse to 192.168.2.100 Net mask to 255.255.255.0
Gateway to 192.168.1.10 Port Number to 10001
Reset Ethernet TCP/IP RESETH
Read the MAC address Ethernet MAC address EMAC ?
License code for optional XENAX® functionalities. Generate from the MAC-address
License code LICC License code / ?
Read the internal license’s-register Bit 0 LINAX enabled
Bit 1 I-FORCE enabled
License register LICR ?
Allowable baud rate: 345600, 256000, 128000, 115200 (default), 57600, 19200,9600
Serial baud rate SERB Baud rate / ?
Deactivate the plausibility checking of the encoder’s signals. After reset ON.
0: Encoder plausibility checking ON 1: Encoder plausibility checking OFF
Encoder Plausibility ENCPD? 0 , 1 / ?
Return the all the versions : FW, Bootloader, WebMotion® Version All VERA
2.3.2 Save / Open application
Previous application’s backup file or startup key from XENAX® Xvi 75V8, are not compatible with
XENAX® Xvi 48V8.
The new application file for XENAX® Xvi 48V8 is coded in JSON format, the advantage is that only one
editable file is saved.
On XENAX® Xvi 75V8 the application is always saved in Motorola-File and Text-File.
13
2.4 Error code for XENAX® Xvi 48V8
F-Number Description Note
Warning 21 Force license missing Calibration value are existing in motor,
but there is no force license active
Error 78 MAC-address not valid The XENAX® Xvi48V8 MAC-address is not valid, please contact the
Jenny Science AG company 95 License missing License error, a programmed function could not be started while
the necessary license is missing .
Note This instruction manual contains copyright protected
information. All rights are reserved. This document may not be in its entirety or partially copied,
duplicated or translated without the prior consent of Jenny Science AG.
Jenny Science AG grants no guarantee on, or will be
held responsible for, any incidents resulting from false information.
Information in this instruction manual is subject to
change.
Jenny Science AG Sandblatte 7a
CH-6026 Rain, Schweiz
Tel +41 (0) 41 455 44 55 Fax +41 (0) 41 455 44 50
www.jennyscience.ch [email protected]