XCAL
Quick Operation Handbook
Version 1.0
Date: 12 May 2011
XCAL Quick Operation Handbook
Proprietary & Confidential Accuver APAC Ltd www.accuver.com
Page 2
Table of Contents
1. Introduction ................................................................................................................ 3
2. Setting Up the System ................................................................................................. 3
2.1 Install XCAL software .......................................................................................................... 3
2.2 Install Device Driver ............................................................................................................ 3
2.3 Configure laptop setting ..................................................................................................... 4
3. Getting Started ............................................................................................................ 5
3.1 Starting XCAL ...................................................................................................................... 5
3.2 User Interface ..................................................................................................................... 5
4. Connecting the Device (Port Setting) ............................................................................ 6
4.1 Connect the devices ........................................................................................................... 6
4.2 Port Setting ......................................................................................................................... 6
4.2.1 Mobile device, Modem or CPE .................................................................................... 6
4.2.2 GPS .............................................................................................................................. 9
4.2.3 Scanner ....................................................................................................................... 9
5. AutoCall Setting ........................................................................................................ 10
5.1 AutoCall Scenario Setting ................................................................................................. 10
5.2 Measurement Window ..................................................................................................... 13
5.2.1 Call Statistics (Current Scenario) ............................................................................... 13
5.2.2 Measurement Window ............................................................................................. 14
5.3 Stop Auto Call ................................................................................................................... 14
6. Map .......................................................................................................................... 15
6.1 Setting the Map Engine .................................................................................................... 15
6.2 Loading the Map ............................................................................................................... 16
6.3 Using the Map ...................................................................................................................17
6.4 Loading the BTS file .......................................................................................................... 18
7. Setting ...................................................................................................................... 19
7.1 Save & Load All Setting ..................................................................................................... 19
7.2 Save & Load Auto Call Scenario ........................................................................................ 19
8. Misc.......................................................................................................................... 19
9. Revision History ........................................................................................................ 20
10. Contact ..................................................................................................................... 20
XCAL Quick Operation Handbook
Proprietary & Confidential Accuver APAC Ltd www.accuver.com
Page 3
1. Introduction
This document intends to the potential user who are going to operate Accuver XCAL drive test
platform. This operation handbook describes the basic operation of XCAL. The more in-depth
operation should refer to user guide and other documents.
2. Setting Up the System
2.1 Install XCAL software
Before you start, make sure you have Administrative Right of laptop. Execute the latest XCAL
setup file (EXE). Several components are to be installed:
XCAL Software: XCAL Main Software
SmartMap: Map display engine. Support WGS84 tab file only.
MS Visual C++ 2008 redistribute: Graphical display module
WinPcap: TCP/IP packet capturing module
MS .NET Framework 2.0 SP1: If the laptop has already installed a higher version, you
can skill the installation of this component.
MapXtreme Runtime NCP: Map display engine.
FFDshow: WAP(WIS) call test. (Optional)
HDD Software Serial Port Monitoring: Capturing modle for CDMA/WiMAX dual mode
devices (Optional)
Reminder: Reboot laptop after installation.
2.2 Install Device Driver
Install the device driver for the peripheral. The device driver usually comes with the device
package. Contact the suppliers to get the driver.
USB License dongle
Mobile Device (Mobile, Modem, CPE)
RF Scanner
GPS (NMEA type)
XCAL Quick Operation Handbook
Proprietary & Confidential Accuver APAC Ltd www.accuver.com
Page 4
2.3 Configure laptop setting
Configure the laptop before starting XCAL.
Turn off window firewall: Go to Control Panel > Window Firewall > General > Select Off.
Turn off Automatic update: Go to Control Panel > Automatic Updates > Select Turn off
Automatic Update.
Turn off Windows Time Synchronization (optional): Go to Control Panel > Date and
Time > Internet Time > uncheck Automatically Synchronize..
Turn off User Account Control (Vista): Go to Control Panel > User Accounts > Turn User
Account Control on or off > uncheck Use User Account. .
Modify User Account Control (Win7): Go to Control Panel > System and Security >
Change User Account Control Settings > Set to Never notify
XCAL Quick Operation Handbook
Proprietary & Confidential Accuver APAC Ltd www.accuver.com
Page 5
3. Getting Started
3.1 Starting XCAL
Make sure the license USB dongle is plugged in to the laptop. (Or the software license
is installed.)
Run the XCAL software from main menu: Start > All Programs > Accuver > XCAL
3.2 User Interface
XCAL Version: Display the current XCAL version
Menu Bar: The function and menu of the XCAL. The content of menus are changed
according to the license options.
Icon Bar: Mostly used function in large icon.
Work Space: Work area to put measurement window
Worksheet: Collection of Workspace
Status Bar: Mobile device, Scanner and GPS connection status. Logging Status.
XCAL Version
Work Space
Status Bar Worksheet
Icon Bar
Menu Bar
XCAL Quick Operation Handbook
Proprietary & Confidential Accuver APAC Ltd www.accuver.com
Page 6
4. Connecting the Device (Port Setting)
4.1 Connect the devices
Connect the mobile device, GPS and/or Scanner to the laptop.
Make sure all the device driver are installed probably.
4.2 Port Setting
4.2.1 Mobile device, Modem or CPE
1. Click Port button on the Icon Bar
2. Check Mobile 1 and click button.
3. Enter any name in the Interface
4. Select Chip Type and Phone Model. Keep Baud Rate and Flow Control as default.
5. Select Modem or Network Adapter of the mobile devices.
6. Enter Dial Num, User ID, Password and Extra String for the data call.
7. Enter any name in the LogMask Alias.
8. Select the check box under each category (HSDPA, GSM, CDMAetc) in which the data
parameter shall be recorded.
9. Click Add/Edit button to add the Log Mask
1
2
XCAL Quick Operation Handbook
Proprietary & Confidential Accuver APAC Ltd www.accuver.com
Page 7
10. Click Add/Edit button to save the Mobile device configuration.
11. Click OK button.
3 4
5
6
8
7 9
10
11
XCAL Quick Operation Handbook
Proprietary & Confidential Accuver APAC Ltd www.accuver.com
Page 8
12. Check Mobile 1
13. Select from the Interface which is created above
14. Select the DM Port, Modem and AT Port.
15. Repeat 12 to 14 when you have more than one device to be used.
16. Click OK button at the bottom right hand corner.
When the devices are configured probably, they are shown blue in color in the status bar at
the bottom of the window. Repeat the above steps if it shows red in color.
Reminder: Port Setting method of mobile phone, modem and CPE are different. Contact
Accuver support team when the devices are not setting up.
XCAL Quick Operation Handbook
Proprietary & Confidential Accuver APAC Ltd www.accuver.com
Page 9
4.2.2 GPS
Select Com Port for the GPS. In general, the GPS is recognized as Prolific USB-to-Serial
Comm Port. Set GPS Type to NMEA and Baud Rate to 4800.
4.2.3 Scanner
Scanner setting is similar to Mobile device. Please refer to document on setting up
scanner.
XCAL Quick Operation Handbook
Proprietary & Confidential Accuver APAC Ltd www.accuver.com
Page 10
5. AutoCall Setting
5.1 AutoCall Scenario Setting
1. Click AutoCall button on the Icon Bar
2. Click button to add the Scenario Test
3. Enter the Scenario Name
4. Select the call test type (voice, FTP, Ping) from the Tap
5. Enter the Call timer for Idle Time, Setup Time, T. Setup Time, Traffic Time and call
Count
6. Input the information of the call test. (e.g. Call Type, Dialed number, AMR Rate)
7. Click OK button at bottom.
1
2
XCAL Quick Operation Handbook
Proprietary & Confidential Accuver APAC Ltd www.accuver.com
Page 11
8. Assign the scenario to the Mobile by Drag & Drop the scenario to each Mobile
9. Select Logging Option for the log saving option. Choose Each Scenario to save log per
call scenario.
10. Click OK to start Auto Call Test.
Note Data logging is started automatically when Auto Call start.
3
7
4 5
6
XCAL Quick Operation Handbook
Proprietary & Confidential Accuver APAC Ltd www.accuver.com
Page 12
Reminder: This is a brief setting on a call test scenario. Please refer to the document on the
Auto Call Setting for more information.
9
8. Drag & Drop
10
XCAL Quick Operation Handbook
Proprietary & Confidential Accuver APAC Ltd www.accuver.com
Page 13
5.2 Measurement Window
5.2.1 Call Statistics (Current Scenario)
Click Statistics/Status > Call Statistics (Current Scenario) from the menu bar
Display the status and statistics of the call test of each mobile.
XCAL Quick Operation Handbook
Proprietary & Confidential Accuver APAC Ltd www.accuver.com
Page 14
5.2.2 Measurement Window
In the Menu Bar, select the measurement window from the drop down menu.
Example of measurement window:
5.3 Stop Auto Call
1. Click Call Stop button to stop Auto Call
XCAL Quick Operation Handbook
Proprietary & Confidential Accuver APAC Ltd www.accuver.com
Page 15
6. Map
6.1 Setting the Map Engine
1. Click Map button on the Icon Bar
2. Click to set the Map Engine
3. Select MapXtreme
4. Click OK button
1
4
3
2
XCAL Quick Operation Handbook
Proprietary & Confidential Accuver APAC Ltd www.accuver.com
Page 16
6.2 Loading the Map
1. Click button
2. Click button and select the map TAB, GST or MWS file.
3. Click OK button
1
2
3
XCAL Quick Operation Handbook
Proprietary & Confidential Accuver APAC Ltd www.accuver.com
Page 17
6.3 Using the Map
Basic Map operation (Zoom In/Out) are located at the top of the Map window
Check the parameter to be shown on the map.
Parameter
Map Icon
XCAL Quick Operation Handbook
Proprietary & Confidential Accuver APAC Ltd www.accuver.com
Page 18
6.4 Loading the BTS file
1. In Menu Bar, go to Setting > BTS Manager.
2. Click Import button on the bottom left hand corner.
3. Check Exclude first line. Uncheck All sectors per line.
4. Click Open File button
5. Select the BTS file (XLS, CSV, TXT or INI) and click Open
6. Select the Field name of each column.
7. Click New button to load the BTS info.
XCAL Quick Operation Handbook
Proprietary & Confidential Accuver APAC Ltd www.accuver.com
Page 19
7. Setting
7.1 Save & Load All Setting
To save all the Port Setting, Auto call, Worksheet:
1. In Menu Bar, click Setting > Save All Settings
2. Select the folder and enter the file name (*.set) and click Save.
To load all the Port Setting, Auto call, Worksheet:
1. In Menu Bar, click Setting > Load All Settings
2. Select the *.set file and click Open.
7.2 Save & Load Auto Call Scenario
1. Open Auto Call Scenario.
2. Click to save the Auto Call Scenario (*.sc)
3. Click to load the Auto Call Scenario (*.sc)
8. Misc
Inbuilding Test: please refer to the guideline of Inbuilding test
Using RF Scanner: please refer to the quick guide of using RF scanner
Load Auto Call
Save Auto Call
XCAL Quick Operation Handbook
Proprietary & Confidential Accuver APAC Ltd www.accuver.com
Page 20
9. Revision History
Version Date Description
1.0 12-May-2011 First Draft
10. Contact
Accuver APAC Limited
Unit 206, 2/F., No. 8 Science Park West Avenue
Hong Kong Science Park, Shatin
New Territories, Hong Kong
TEL: +852 2210 7004
FAX: +852 2210 7017
Web: http://www.accuver.com