31
AEROTECNICA COLTRI www.coltrisub-asiapacific.co m NITROX PRODUCTION WITHIN A DIVE OPERATION Presented by: Cesare Benelli,Coltri Sub & Glenn Huebner, Nuvair

Www.coltrisub-asiapacific.com NITROX PRODUCTION WITHIN A DIVE OPERATION Presented by: Cesare Benelli,Coltri Sub & Glenn Huebner, Nuvair Presented by: Cesare

Embed Size (px)

Citation preview

Page 1: Www.coltrisub-asiapacific.com NITROX PRODUCTION WITHIN A DIVE OPERATION Presented by: Cesare Benelli,Coltri Sub & Glenn Huebner, Nuvair Presented by: Cesare

AEROTECNICA COLTRI AEROTECNICA COLTRI -www.coltrisub asiapacific.com

NITROX PRODUCTION WITHIN A DIVE OPERATION

Presented by:

Cesare Benelli,Coltri Sub & Glenn Huebner, Nuvair

Presented by:

Cesare Benelli,Coltri Sub & Glenn Huebner, Nuvair

Page 2: Www.coltrisub-asiapacific.com NITROX PRODUCTION WITHIN A DIVE OPERATION Presented by: Cesare Benelli,Coltri Sub & Glenn Huebner, Nuvair Presented by: Cesare

AEROTECNICA COLTRI AEROTECNICA COLTRI -www.coltrisub asiapacific.com

WHAT IS “NITROX”?

N2O2

Also referred to as EAN, EaNX,

Enriched air, & Enriched air nitrox

A gas mixture containing nitrogen &

oxygen with a higher % of oxygen

than normal breathing air

OEA - Oxygen enriched air

Page 3: Www.coltrisub-asiapacific.com NITROX PRODUCTION WITHIN A DIVE OPERATION Presented by: Cesare Benelli,Coltri Sub & Glenn Huebner, Nuvair Presented by: Cesare

AEROTECNICA COLTRI AEROTECNICA COLTRI -www.coltrisub asiapacific.com

WHY DO RECREATIONAL DIVERS USE NITROX?

Less N2 absorption in body tissue.

Lessens risk of decompression sickness.

Provides longer bottom times.

Increases safety margins.

Popular with Dive masters & instructors.

Page 4: Www.coltrisub-asiapacific.com NITROX PRODUCTION WITHIN A DIVE OPERATION Presented by: Cesare Benelli,Coltri Sub & Glenn Huebner, Nuvair Presented by: Cesare

AEROTECNICA COLTRI AEROTECNICA COLTRI -www.coltrisub asiapacific.com

WHEN CAN RECREATIONAL DIVERS USE NITROX?

On all recreational dives.

Leading training agencies have

introduced optional nitrox training

within entry level courses.

Leading training agencies have

also introduced introductory

programs to initiate divers to nitrox

prior qualification

Page 5: Www.coltrisub-asiapacific.com NITROX PRODUCTION WITHIN A DIVE OPERATION Presented by: Cesare Benelli,Coltri Sub & Glenn Huebner, Nuvair Presented by: Cesare

AEROTECNICA COLTRI AEROTECNICA COLTRI -www.coltrisub asiapacific.com

WHAT % OF REC DIVERS ARE USING NITROX?

Exact figures not known, but tens of 1000’s of divers train each year with Nitrox

Many dive resorts & liveaboard/charter vessels are already providing nitrox

Page 6: Www.coltrisub-asiapacific.com NITROX PRODUCTION WITHIN A DIVE OPERATION Presented by: Cesare Benelli,Coltri Sub & Glenn Huebner, Nuvair Presented by: Cesare

AEROTECNICA COLTRI AEROTECNICA COLTRI -www.coltrisub asiapacific.com

TRAINING REQUIRED FOR THE USE OF NITROX

Courses are available from all

major DSAT agencies

Basic Nitrox training allows diving

with up to 40% mix

Technical Nitrox training is required

for mixes over 40%

Page 7: Www.coltrisub-asiapacific.com NITROX PRODUCTION WITHIN A DIVE OPERATION Presented by: Cesare Benelli,Coltri Sub & Glenn Huebner, Nuvair Presented by: Cesare

AEROTECNICA COLTRI AEROTECNICA COLTRI -www.coltrisub asiapacific.com

WHY OFFER NITROX ?

To increases potential revenue

Provides more & diverse diving opportunities for clients.

Provides additional training opportunities & revenue

Attracts more customers to your dive centre / vessel

Extra equipment sales

Page 8: Www.coltrisub-asiapacific.com NITROX PRODUCTION WITHIN A DIVE OPERATION Presented by: Cesare Benelli,Coltri Sub & Glenn Huebner, Nuvair Presented by: Cesare

AEROTECNICA COLTRI AEROTECNICA COLTRI -www.coltrisub asiapacific.com

ADDITIONAL REASONS TO OFFER NITROX.

Reduction of DCS exposure to divers on multi-day dive trips

Reduces operator, Dive master & Instructor liability

Provides a marketing edge over competitors.

Adoption of Nitrox by all major training agencies

Emergence of ‘tech’ diving within the mainstream.

Page 9: Www.coltrisub-asiapacific.com NITROX PRODUCTION WITHIN A DIVE OPERATION Presented by: Cesare Benelli,Coltri Sub & Glenn Huebner, Nuvair Presented by: Cesare

AEROTECNICA COLTRI AEROTECNICA COLTRI -www.coltrisub asiapacific.com

WHO ELSE USES NITROX?

Recreational dive

professionals

Public safety divers

Scientific divers

Commercial divers

NASA astronauts

Page 10: Www.coltrisub-asiapacific.com NITROX PRODUCTION WITHIN A DIVE OPERATION Presented by: Cesare Benelli,Coltri Sub & Glenn Huebner, Nuvair Presented by: Cesare

AEROTECNICA COLTRI AEROTECNICA COLTRI -www.coltrisub asiapacific.com

HOW IS NITROX DELIVERED TO THE DIVER?

Specially marked cylinders

Diver must have proof of nitrox

certification

Diver must analyze gas

Diver must sign gas log

For ‘Nitrox Experience’ programs

Certified DM/Instructors to comply

with above procedures.

Page 11: Www.coltrisub-asiapacific.com NITROX PRODUCTION WITHIN A DIVE OPERATION Presented by: Cesare Benelli,Coltri Sub & Glenn Huebner, Nuvair Presented by: Cesare

AEROTECNICA COLTRI AEROTECNICA COLTRI -www.coltrisub asiapacific.com

NITROX PRODUCTION OPTIONS:

• PARTIAL PRESSURE BLENDING

• CONTINUOUS FLOW BLENDING

• MEMBRANE SYSTEM

Page 12: Www.coltrisub-asiapacific.com NITROX PRODUCTION WITHIN A DIVE OPERATION Presented by: Cesare Benelli,Coltri Sub & Glenn Huebner, Nuvair Presented by: Cesare

AEROTECNICA COLTRI AEROTECNICA COLTRI -www.coltrisub asiapacific.com

PARTIAL PRESSURE BLENDING

1. Decant 100% pure O2 to dive cylinder **

2. Top off with O2 J grade compatible air **

** Amounts vary according to required mix and cylinder contents & must be calculated.

Page 13: Www.coltrisub-asiapacific.com NITROX PRODUCTION WITHIN A DIVE OPERATION Presented by: Cesare Benelli,Coltri Sub & Glenn Huebner, Nuvair Presented by: Cesare

AEROTECNICA COLTRI AEROTECNICA COLTRI -www.coltrisub asiapacific.com

ADVANTAGES OF PARTIAL PRESSURE BLENDING

Lowest start up costs of

blending methods.

Popular with technical divers

Page 14: Www.coltrisub-asiapacific.com NITROX PRODUCTION WITHIN A DIVE OPERATION Presented by: Cesare Benelli,Coltri Sub & Glenn Huebner, Nuvair Presented by: Cesare

AEROTECNICA COLTRI AEROTECNICA COLTRI -www.coltrisub asiapacific.com

DISADVANTAGES OF PARTIAL PRESSURE BLENDING

Requires transport and handling of 100% pure high pressure O2

Requires error free mathematical calculations

Requires special filtration & expensive consumables to reach J grade quality air.

Requires trained/certified gas blending technician.

Page 15: Www.coltrisub-asiapacific.com NITROX PRODUCTION WITHIN A DIVE OPERATION Presented by: Cesare Benelli,Coltri Sub & Glenn Huebner, Nuvair Presented by: Cesare

AEROTECNICA COLTRI AEROTECNICA COLTRI -www.coltrisub asiapacific.com

ADDITIONAL DISADVANTAGES OF P/P BLENDING

Mix may not be exact +/-

P/P blending should be very slow

100% O2 availability

Purchase & transport costs of

100% O2

High levels of liability for operators

Page 16: Www.coltrisub-asiapacific.com NITROX PRODUCTION WITHIN A DIVE OPERATION Presented by: Cesare Benelli,Coltri Sub & Glenn Huebner, Nuvair Presented by: Cesare

AEROTECNICA COLTRI AEROTECNICA COLTRI -www.coltrisub asiapacific.com

CONTINUOUS FLOW BLENDING

1. Gas is pre-mixed using O2 & breathing air with a blending panel

2. Normal high pressure

compressor is used to fill cylinder

Page 17: Www.coltrisub-asiapacific.com NITROX PRODUCTION WITHIN A DIVE OPERATION Presented by: Cesare Benelli,Coltri Sub & Glenn Huebner, Nuvair Presented by: Cesare

AEROTECNICA COLTRI AEROTECNICA COLTRI -www.coltrisub asiapacific.com

ADVANTAGES OF CONTINUOUS FLOW BLENDING

Relatively inexpensive More practical & faster than

partial pressure blending

If using an automated blending panel its is an easy to use & precise method. The panel achieves reduction of associated O2

handing risks with the use of

auto O2 cut - off valves

Page 18: Www.coltrisub-asiapacific.com NITROX PRODUCTION WITHIN A DIVE OPERATION Presented by: Cesare Benelli,Coltri Sub & Glenn Huebner, Nuvair Presented by: Cesare

AEROTECNICA COLTRI AEROTECNICA COLTRI -www.coltrisub asiapacific.com

DISADVANTAGES OF CONTINUOUS FLOW BLENDING

100% O2 availability

Purchase & transport costs

of 100% O2

High levels of liability for

operators

Page 19: Www.coltrisub-asiapacific.com NITROX PRODUCTION WITHIN A DIVE OPERATION Presented by: Cesare Benelli,Coltri Sub & Glenn Huebner, Nuvair Presented by: Cesare

AEROTECNICA COLTRI AEROTECNICA COLTRI -www.coltrisub asiapacific.com

MEMBRANE SYSTEM NITROX PRODUCTION Normal Air filtered to Grade E standard & pumped into membrane @

low pressure

O2 permeates thru membrane more than N2 . N2 rich mix vented, O2 rich mix pumped into high pressure compressor **

Normal high pressure compressor used to fill cylinder. ** N2O2 mix controlled via air flow rate into membrane.

Page 20: Www.coltrisub-asiapacific.com NITROX PRODUCTION WITHIN A DIVE OPERATION Presented by: Cesare Benelli,Coltri Sub & Glenn Huebner, Nuvair Presented by: Cesare

AEROTECNICA COLTRI AEROTECNICA COLTRI -www.coltrisub asiapacific.com

POSSIBLE MEMBRANE SYSTEMS

LP compressor - LP filtration - Membrane - HP compressor - cylinder

Page 21: Www.coltrisub-asiapacific.com NITROX PRODUCTION WITHIN A DIVE OPERATION Presented by: Cesare Benelli,Coltri Sub & Glenn Huebner, Nuvair Presented by: Cesare

AEROTECNICA COLTRI AEROTECNICA COLTRI -www.coltrisub asiapacific.com

POSSIBLE MEMBRANE SYSTEMS

Air bank - LP pressure reducer - LP filtration - Membrane - HP compressor - Cylinder

Page 22: Www.coltrisub-asiapacific.com NITROX PRODUCTION WITHIN A DIVE OPERATION Presented by: Cesare Benelli,Coltri Sub & Glenn Huebner, Nuvair Presented by: Cesare

AEROTECNICA COLTRI AEROTECNICA COLTRI -www.coltrisub asiapacific.com

ADVANTAGES OF A MEMBRANE SYSTEM

Simple operation

No need to store or mix high-

pressure O2

Virtually eliminates hazards

associated with handling 100% O2

Highly accurate method of

blending

Page 23: Www.coltrisub-asiapacific.com NITROX PRODUCTION WITHIN A DIVE OPERATION Presented by: Cesare Benelli,Coltri Sub & Glenn Huebner, Nuvair Presented by: Cesare

AEROTECNICA COLTRI AEROTECNICA COLTRI -www.coltrisub asiapacific.com

ADDITIONAL ADVANTAGES OF MEMBRANE SYSTEMS

FAST: Fill nitrox tanks at same speed you fill with air

LOW: Maintenance & operating costs.

SIMPLE: Training & use.

Note:Note: Membrane systems have the lowest levels of Membrane systems have the lowest levels ofOperator risk exposure when filling Nitrox cylinders.Operator risk exposure when filling Nitrox cylinders.

Page 24: Www.coltrisub-asiapacific.com NITROX PRODUCTION WITHIN A DIVE OPERATION Presented by: Cesare Benelli,Coltri Sub & Glenn Huebner, Nuvair Presented by: Cesare

AEROTECNICA COLTRI AEROTECNICA COLTRI -www.coltrisub asiapacific.com

RELIABILITY OF THE COLTRI /NUVAIR MEMBRANE

Systems reliable as a normal

air compressor systems

20-30 year life span

Compressor are covered by

1 year warranty

Membrane systems are

covered by 5 year warranty.

Note:Note: It is Important stated maintenance procedures It is Important stated maintenance procedures are followedare followed

Page 25: Www.coltrisub-asiapacific.com NITROX PRODUCTION WITHIN A DIVE OPERATION Presented by: Cesare Benelli,Coltri Sub & Glenn Huebner, Nuvair Presented by: Cesare

AEROTECNICA COLTRI AEROTECNICA COLTRI -www.coltrisub asiapacific.com

DISADVANTAGES OF A MEMBRANE SYSTEM?

Higher initial capital investment

May require additional electrical

power

Page 26: Www.coltrisub-asiapacific.com NITROX PRODUCTION WITHIN A DIVE OPERATION Presented by: Cesare Benelli,Coltri Sub & Glenn Huebner, Nuvair Presented by: Cesare

AEROTECNICA COLTRI AEROTECNICA COLTRI -www.coltrisub asiapacific.com

IS A NEW HP COMPRESSOR NEEDED FOR NITROX?

Can usually use your existing compressor .

A well maintained ‘used’ compressor may need a mild overhaul and internal cleanup if previously used with mineral oil.**

** Any HP Compressor used to compress Nitrox must be lubricated by a synthetic oil rated for use with nitrox

Page 27: Www.coltrisub-asiapacific.com NITROX PRODUCTION WITHIN A DIVE OPERATION Presented by: Cesare Benelli,Coltri Sub & Glenn Huebner, Nuvair Presented by: Cesare

AEROTECNICA COLTRI AEROTECNICA COLTRI -www.coltrisub asiapacific.com

IS USING NITROX WITH A HP COMPRESSOR SAFE?

There are attendant risks with compressing any gas

Compressing N2O2

containing 40% or less O2

poses no more risk than pumping normal breathing air at higher pressures

Page 28: Www.coltrisub-asiapacific.com NITROX PRODUCTION WITHIN A DIVE OPERATION Presented by: Cesare Benelli,Coltri Sub & Glenn Huebner, Nuvair Presented by: Cesare

AEROTECNICA COLTRI AEROTECNICA COLTRI -www.coltrisub asiapacific.com

WHEN USING MEMBRANE OR CONTINUOUS BLENDING…

Considerations:

Slightly more conservative than compressing air

Compressor oil

Compressor operating temp.

Filtration

Page 29: Www.coltrisub-asiapacific.com NITROX PRODUCTION WITHIN A DIVE OPERATION Presented by: Cesare Benelli,Coltri Sub & Glenn Huebner, Nuvair Presented by: Cesare

AEROTECNICA COLTRI AEROTECNICA COLTRI -www.coltrisub asiapacific.com

WHAT IF I NEED TO PRODUCE 40%+ NITROX MIX?

Recreational Divers will not use more than 40% Nitrox

The most popular mix currently used within dive centers/vessels is 32%

If a deco mix exceeding 40% is required by tech divers a P/P system can be used.

Note: Recommended depth limit for recreational divers is 30m, best suited to a 32% Nitrox mix

Page 30: Www.coltrisub-asiapacific.com NITROX PRODUCTION WITHIN A DIVE OPERATION Presented by: Cesare Benelli,Coltri Sub & Glenn Huebner, Nuvair Presented by: Cesare

AEROTECNICA COLTRI AEROTECNICA COLTRI -www.coltrisub asiapacific.com

TRAINING STAFF TO FILL NITROX TANKS

Most people can learn to operate a membrane nitrox system in less than one hour.

We will be conducting a live demonstration at the end of this session

Page 31: Www.coltrisub-asiapacific.com NITROX PRODUCTION WITHIN A DIVE OPERATION Presented by: Cesare Benelli,Coltri Sub & Glenn Huebner, Nuvair Presented by: Cesare

AEROTECNICA COLTRI AEROTECNICA COLTRI -www.coltrisub asiapacific.com

END OF PART ONE