AIR COOLED CHILLER
WSA Techno
2
Your Future
is already
in our
Mind
3
4
5
Index
Versions..................................................................................................................................................................6Applications ........................................................................................................................................................ 7Dimensions ..........................................................................................................................................................8Options ....................................................................................................................................................................9Screw Compressor ......................................................................................................................................10Condenser ...........................................................................................................................................................11Expansion valve.............................................................................................................................................. 12Evaporator .......................................................................................................................................................... 13Structure .............................................................................................................................................................. 14Electrical Panel ...............................................................................................................................................15Hydraulic Kit ......................................................................................................................................................16Display Touch ...................................................................................................................................................18Movements ........................................................................................................................................................19SEC.blue Electronic Control .................................................................................................................20Low Noise ...........................................................................................................................................................21Free Cooling .....................................................................................................................................................22EER - ESEER - IPLV ......................................................................................................................................23Quality................................................................................................................................................................... 24Refrigeration Circuit ................................................................................................................................... 25
8 fans ...................................................................................................................................................................2512 fans ................................................................................................................................................................2616 fans ................................................................................................................................................................2724 fans ............................................................................................................................................................... 28
Free Cooling Circuit ................................................................................................................................... 298 fans .................................................................................................................................................................. 2912 fans ................................................................................................................................................................3016 fans ................................................................................................................................................................ 3124 fans ................................................................................................................................................................32
Encoding .............................................................................................................................................................33Working limits ................................................................................................................................................. 34Free space ........................................................................................................................................................ 35Pumps curves ................................................................................................................................................. 36Technical data ................................................................................................................................................ 39
Subject to change without notice
6
Low NoiseWSA Techno is an highly silenced unit, thanks to the adoption of acoustic insulations, specifically designed and placed in the compressor compartment (ISO 3744).In order to maximise the noise reduction the maximum speed of the fans is limitated. The optimization of the coils/fans group allows to limit the cooling capacity reduction compared to the standard version.Available for all sizes of WSA Techno.
StandardThe Techno range expands the series of high efficiency chillers for industrial, IT and comfort applications, made by COSMOTEC. WSA are chillers for outdoor installation, specifically designed to have high perfor-mance with small footprint.Efficency, strength and reliability at COSMOTEC levels.
Versions
Outdoor installationWSA Techno is designed to be used on any outdoor installation. The electrical panel, with IP54 protection, guarantees an adequate security for electric and electronic components. The different options allow a further extension of the operating limits both at low and high temperatures, with enhanced protection for highly corrosive environments.
Gas R134aAll units of the WSA Techno range use refrigerant gas R134a, which ensures an higher cooling capacity with low footprint of the machine.The R134a assures a very low environmental impact, low impact on the ozone and a greenhouse gas coefficient lower than the usual refrigerants.
Free CoolingThe free cooling circuit is composed by condensing coil with copper tubes and aluminium fins. Two 2-ways valves controlled by SEC.blue, to ensure the maximum yield, minimizing the compressor opera-tion time and reducing the running costs by lowering pressure losses.There is a Cataphoresis treatment on the condensing coils, in order to prevent corrosion due to stray currents.When the ambient temperature drops down, the SEC.blue controller partialises even further the 2-ways valves and the fans, guaranteeing the correct thermal load management.Due to the need to maximize the air flow through the batteries.The “Super Silent” version on Free Cooling is only uppon request.
All versions have:
The right solution for you
7
Aerospace
Automotive
Plastic
Automation
Renewable Energy
Precious Metals
Hospital
Applications
One technology, many uses
Air ambient temperature: -20°C / +45°C Water inlet temperature: +0°C / +30°C Water outlet temperature: -5°C / +25°C
Process Cooling & Industrial applications
Comfort
Air ambient temperature: -20°C / +45°C Water inlet temperature: +12°C / +22°C Water outlet temperature: +7°C / +18°C
8
1125 - 1260 kW (1)
845 - 910 - 1030 kW (1)
630 - 670- 740 kW (1)
370 - 480 kW (1)
24fans
16fans
12fans
8fans
(1) Air ambient temperature: +35°C Water inlet temperature: +12°C Water outlet temperature: +7°C
Dimensions
One size for every need
Height 2473 mm
Lenght 2278 mm
Depth 4255 ÷ 4635 mm
Height 2473 mm
Lenght 2278 mm
Depth 6960 mm
Height 2473 mm
Lenght 2278 mm
Depth 8120 ÷ 8880 mm
Height 2473 mm
Lenght 2278 mm
Depth 11980 mm
Weight 4900 ÷ 5800 kg
Weight 5000 ÷ 6400 kg
Weight 6250 ÷ 8900 kg
Weight 7640 ÷ 11900 kg
9
SoftstartDevice for reducing mechanical stress during compressor start-up. The device partialises the starting current of the compressors by reducing the stress on the power supply line and preserving the compressors’ components.
Automatic transfer switchThree-phase switch without neutral, with automatic or manual control (by key). Functions dedicated to network/backup unit installation, with checking function for the switching capability verify and backup unit test. Voltage and frequency control. Switch installed inside the electrical panel. Auxiliary contacts to report the line switching.
Magnetotermic switch (A.C.B.)The magnetothermic switches guarantee an high protection against inrush current, which can damage the downstream component. Thanks to the magnetothermic switch after the intervention it’s possible to restart the chiller without replace the components.
Energy meterMeter to control the electric energy required by the chiller. LCD display to visualize current values, voltage, instant values of the 3 phases, average and maximum historical values. Remote control data through ModBus RTU.This component is installed inside the electrical panel.
Power factor corrections capacitorsThe power factor correction capacitors can take back to a 0.95 cosφ the phase displacement, which can be caused by magnetic fields. The capacitors are managed by the SEC.blue electronic control.
Flow switchComponent that verifies the flow of the fluid in the circuit. Installed on the return pipe. The flow switch is electrically connected to the SEC.blue control and reports the absence of fluid circulation, preventing damage to the hydraulic components.
Antifreeze heatersElectric heaters controlled by the SEC.blue prevent the icing of the fluid inside the hydraulic circuit. In case of particularly harsh work conditions the use of a correct amount of ethylene or propylene glycol is suggested.
Coils treatment Protective cataphoresis or epoxy treatment in order to enhance the coils resistance in aggressive environments. The cataphoresis treatment is a standard on the condenser coils in Free Cooling version.
Closing GridThe protective grids protect the condensing coils, preserve the correct air flow and prevent access to the components. Made in zinc coated metal sheet painted with epoxy powders.Standard color: RAL 9005 paint smooth.
Supply without refrigerant gasIt is possible to ship the chillers without the hazardous refrigerant gas, in case of particular conditions of shipment. In these cases the gas is substitute by nitrogen. The refrigerant charges are reported on the nameplate.
ContainerizationThe chiller can be loaded into a 40 feet high cube container.
Anti-vibration mount springs, antisismicSupports specifically designed to bear the chiller weight and to avoid the transmission of vibrations to the underlying structure during operation.
Options
Made for you
Air filterThe metallic filters prevent the condenser clogging caused by the dust in the air. The filters are installed at the condenser inlet through two joint brackets.
10
no.2
Screw Compressor
The Heart of the WSA Techno
Semi-hermetic ScrewThe heart of the COSMOTEC Techno range are the semi-hermetic screw compressors, specifically designed for air cooled refrigerant circuits. These compressors are able to compressing all the ecological refrigerant gases used by COSMOTEC. State of the art compressors, able to achieve high compression ratios with reduced consumption.Thanks to the compressor double screw system the gas is continuously compressed, allowing to maintain the rotation inertia of the compressor motor, avoiding overloads, electrical consumption peaks, reducing mechanical stresses, which are the primary cause of the reduction in the product life.
Sliding ValvesThrough a partialisation slide valve, regulated according to a 0-10 input, is possible to change continuously the refrigerant R134a compression, partialising the cooling capacity supplied.The correct compressor cooling is guaranteed by the refrigerant gas, which, in intake, flows through the rotor windings, maintaining the temperature within the limits provided by the supplier.
StartingA range of compressors with part-winding (WSA160-320) or star-delta (WSA360-640) start-ups are available, depending on the size of the chiller. In both cases to limit the locked rotor current and reduce the stress of the component, the compressor is started with a load of 25%, increased up to 100% after the achievement of the total motor torque.
Two CompressorsThe screw compressors can reach a high cooling capacity with just 1 or 2 compressors installed, while maintaining an high efficiency at partial loads.
11
W
Condenser
Micro Channel
Aluminium
W-Shape
Indipendent circuits
For the best performance
W-Shape GeometryThe MicroChannel condenser coils are entirely made in aluminum and expressly designed and realized to maximize the yield of the chillers, preserving reduced dimensions. The W-shape geometry has an angle designed, tested and proven specifically to avoid points of failure of the batteries and the imbalance of the refrigerant circuits. The use of a W-shape geometry ensures an optimal air flow through the coils, allowing to reduce the noise of the refrigerator both in Chiller or Free Cooling mode.
Axial FansThe proper air flow is guaranteed by the axial fans with phase-cutting partialization, which takes in fresh air from the longitudinal sides of the chiller through the condensers, and push the heated air upwards.The fans are handled by SEC.blue electronic control to maintain the best condensing value in every cooling circuit. The fans can’t be canalized.
Air flow:
12
Expansion valve
The evaporation of the refrigerant gas into the cooling circuits is guaranteed by the latest generation electronic thermostatic valves. Together with appropriate pressure switches, temperature probes and the electronic controller SEC.blue the valves optimize the thermal exchange into the evaporator, preserving the upstream and downstream components from high temperatures or icing.The operating and calibration logic of the electronic thermostatic valves lies in the electronic controller SEC.blue.
Quick start up with super heater control in order to achieve the full cooling capacity in less time.
Wider working range operating limit increased compared to the mechanical expansion valve
Optimization of the exchange surface thanks to the correct evaporation of the liquid in each conditions.
Compressor protected against the back liquid with pressure switch and probe installed on the lower line guarantees the complete transition to gas of the refrigerant before the inlet in the compressor.
Humidity and liquid sightglass incorporated to check the status of the refrigerant
Safety capacitor for shut-down in case of failure of power supply, allows the complete closure of the valve to avoid the return of the liquid into the evaporator.
Indipendent for each cooling circuit properly managed by electronic controller SEC.blue
PLUS
Quality in every component
13
Evaporator
For the best performance
The Shell and tube evaporator is composed by: small inner tubes made by copper, separation baffles for a better heat exchange refrigerant-fluid, outer casing carbon steel coated with suitable thermal insulation, in order to assure the entire range of operation of the chiller.Double cooling circuit and mono circuit water side, disposed in countercurrent flow to maximize the heat exchange between the refrigerant and the fluid, while keeping pressure losses very low on both circuits.Victaulic® water connections for quick installation of the chiller.
Two Refrigerant circuits (pipes) to maximize the heat exchange from the water to the gas.
One Hydraulic circuit (casing) with very low pressure drop
Fully Insulated with adequate thickness with special glass fibre, resistant to the atmospheric agents and U.V., and to reduce the yield loss.
Differential Pressure Switch as standard, to check the flow through the evaporator, to guarantee its safety against icing and stops the chiller functions in case of alarms
Victaulic® Connections for a quick installation
Carbon Steel outer casing + Copper pipes
PLUS
14
Structure
Reticular full metal structure to ensure the resistace of the structure also during the movement operations
Epoxy powder for all the metal structure
Corrosion resistant parts guarantee for all the fixing small parts
Outdoor installation
Lifting plates to handle safely the chiller
Predefined Anti vibranting Holes to install correctly the anti vibranting kit
Made to be strong
The WSA range is produced with a bearing frame of zinc-coated metal sheet painted with epoxy powders; fixing small parts in corrosion resistant steel. Zinc-coated metal sheet painted with epoxy powders closure plugging for condenser, compressors compartment and electrical panel. Yellow plates, properly designed and positioned, are attached and identified to safety lifting with cranes the entire refrigerator. These plates, fixed by screws, can be removed after the positioning or to insert the chiller into a container.Predefined holes in the support structure allow the installation of anti-vibration mounts
Standard Colour RAL 7035, orange peel
PLUS
15
Electrical Panel
Degree of protection IP54 for outdoor installation
Big dimensions to include all the available options
Triple Door
Display with transparent protection panel to manage the chiller
General lock door to guarantee the safety of the user
FEATURES
Protection & Accessibility
Electric panel with big dimensions to allow installation of all options designed, installed in the front side of the chiller.Triple door, ventilated, equipped with external power switch and display to manage the chiller operating.Three-phase power supply 400V/50Hz or 460V/60Hz, secondary supply at 230V with internal transformer. The safety of the motors is guarantee by fuses and thermal protector.The fans speed is managed through a cutting phases devices, by the electronic controller SEC.blue. The cutting phase devices are installed outside of the electrical panel.The inlet of the wires is from the bottom of the cabinet, through specific removable panels
Components and realization in accordance with CEI EN 60335-2-40, CEI EN 61000-6-1/2/3/4 standards and EMC2004/108/CE regulation.
16
TT7
TT4 PDZAL
3
M
MHH
MHH
Hydraulic Kit
Hydraulic circuit composed of painted steel piping, covered in elastomeric insulating material with added glass fib-er, Shell and tube evaporator, charge/discharge/vent valves, Victaulic© connections. The optionals allow to deliver the chiller also with: � 1 pump with shut-off valves upstream and downstream for easy maintenance � 1 pump with independent inverter controller. Shut-off valves upstream and downstream � 2 pumps in redundancy, each with shut-off valves upstream and downstream � 2 pumps in redundancy, each with independent inverter controller � antifreeze heaters installed on the main components of the hydraulic circuit
The inverter is delivered by standard with constant pressure regulation. It’s also available with constant flow regulation (special request).
With n.1 PumpManaged by electronic controller SEC.blue.The pump is available with InverterPump installed before the evaporator.
With n.2 PumpsWhen there are 2 pumps they are in redundan-cy: one is operating and the other is stopped. In case of failure of the first pump the second one turns on.Each pump has shut-off valves upstream and downstream for easy maintenance.Managed by electronic controller SEC.blue.
Only EvaporatorStandard selection for all versions.
Your project, our solution
WATER OUT WATER IN
SHELL & TUBES EVAPORATOR
17
LOW NOISE
FansConnection
Diameter
WSA160 8 6" Victaulic®
WSA220 8 6" Victaulic®
WSA250 12 6" Victaulic®
WSA280 12 6" Victaulic®
WSA300 12 6" Victaulic®
WSA320 16 6" Victaulic®
WSA360 16 8" Victaulic®
WSA380 16 8" Victaulic®
WSA440 16 8" Victaulic®
WSA480 24 8" Victaulic®
WSA640 24 8" Victaulic®
ConnectionsQuick Victaulic© grooved end piping system to ensure: � easy maintenance of the connection � simple alignment of users pipes and chiller � flexibility thanks to the shape of the joint is possible to secure the resistance to thermal expansion, slight misalignments and seismic stress
� noise and vibration attenuation by isolating the transference of vibration at each joint � rigidity to torsional and flexural loads
As options are available Victaulic© adapters to flanged or threaded connection.
BASE
FansConnection
Diameter
WSA160 8 6" Victaulic®
WSA220 8 6" Victaulic®
WSA250 12 6" Victaulic®
WSA280 12 6" Victaulic®
WSA300 12 6" Victaulic®
WSA320 16 6" Victaulic®
WSA360 16 8" Victaulic®
WSA380 16 8" Victaulic®
WSA440 16 8" Victaulic®
WSA480 24 8" Victaulic®
WSA640 24 8" Victaulic®
HYDRAULIC KIT
FREE COOLING
FansConnection
Diameter
WSA160 8 6" Victaulic®
WSA220 8 6" Victaulic®
WSA250 12 6" Victaulic®
WSA280 12 6" Victaulic®
WSA300 12 6" Victaulic®
WSA320 16 6" Victaulic®
WSA360 16 8" Victaulic®
WSA380 16 8" Victaulic®
WSA440 16 8" Victaulic®
WSA480 24 8" Victaulic®
WSA640 24 8" Victaulic®
18
Display Touch
The user interface of the electronic controller SEC.blue is a 7” colour touch screen display, with synoptic useful menus. All the data of the chiller, warnings and alarms will be shown on the display.The menus are available in many languages: Italian, German, English, French, Russian, Spanish.
Example of the synoptics menus:
Language
Free Cooling
Circuit n°2
Circuit n°1
7” TFT-LCD graphical color display
800 x 480 px resolution
Frontal protection IP66 for outdoor installation
Operating limits from -20 up to +60°C
Resistive Touch Screen
LED backlight
Buzzer
4 diagnostic LEDs on pannel
Main features
Full control one touch away
19
Movements
Where you need it, easily
HandlingThe WSA chillers can be handled with cranes or ropes and sling lifting. The chiller is equipped with special lifting yellow plates, purposely designed to handle all the weight of the chiller.
ContainerizationWSA can be put in 40 feet high cube container. To do this is necessary to install two spars under the chill-er after have remove the lifting yellow plates to reduce the dimensions and gain more movement space.
20
The “mind” of the COSMOTEC Techno chiller is the SEC.blue electronic control, developed by COSMOTEC to achieve the best performance from every component. New functions have been implemented in the COSMOTEC Techno range in order to obtain the best management of the new compo-nents. Memory and calculation speed are increased, allowing a better and faster control of all the components and preserv-ing the durability of the units. The numerous functions and parameters are summarized in a few simple steps and screens, which allow the user to easily keep under control the chiller correct operation. A 7” liquid crystal display with touch screen acts as an interface between the user and the chiller. The display reports all the information on: operation status, working time, alarm history and alarm signals. Furthermore it allows to start, stop and modify the chiller operation.
SEC.blue Electronic Control
SEC.blue Electronic Controller manages:
� Compressors = start, switching off, within the limits provided by the supplier
� Fans = depending on the power requested and on the active function (chiller, Free Cooling) sets the fans speed, to guarantee the maximum yield with lesser noise and electric consumption
� Electronic Thermostatic Valves = partialises the refrigerant evaporation to obtain the requested power with the lesser electrical consumption
� Fluid side pumps (where expected) = the electronic control manages the redundancy in case of installation of 2 pumps, in order to maintain the working time of the pumps assimilar as possible.
� Free Cooling circuit = partialising the 3-ways valve, it takes advantage of the entire cooling capacity recoverable from the ambient air.
SEC.blue Electronic Controller is equipped with the following pre-loaded functions:
� Sequencing = to connect through a specific line more chillers and manage the components as a unique chiller
� Emergency Cooling = to activate the chillers in the same line, in case the active chiller cannot make up for the overload of the user.
� Redundancy = activates alternatively the chillers and guarantees the service continuity in case of fault of a chiller.
� ModBus RTU = to manage remotely the chiller through standard interfaces
� STULZ Protocol = to connect the chiller to the STULZ supervision components
� Unloading = guarantees the chiller partialised operation even at high temperatures
� Antifreeze
The Mind
21
880 rpm
0 rpm
670 rpm
Low Noise
In the WSA Techno the noise can be made by the compressors and the air flow through the condensers. It’s possible to reduce the noise level (about -10 dB) selecting the Low Noise Version of WSA Techno.
The noise is reduced with the following solutions:
Acoustic IsolationIn WSA Techno a textile fibre of polyester vane cover each compressor and the pumps.The vanes are made by metal sheet powdered in the same colour of the chiller. The vane allow the complete access to the compressors electrical box.
Fan speed reductionTo reduce the noise caused by the flow of the air through the exchangers, the fans speed is reduced moving the electrical connections from Delta to Star.This solution reduces the speed approximately about 30%. This requires a greater dimension of the condenser coils to achieve the same cooling capacity of the standard version.
STANDARD versionFREE COOLING version
LOW NOISE version
Silent, whenever needed
22
Temperate climateIn temperate climates north and south of the equatorial zone, the energy-saving advantages of Indirect Free Cooling can be fully exploited. Electricity consumption for data center air conditioning will drop by up to 60%.
Free Cooling
The Free Cooling circuit is composed by coil with copper tubes and aluminium fins. Two 2-ways valves, controlled by SEC.blue, ensures the maximum yield, minimizing the compressor operation time and reducing the running costs.Cataphoresis treatment on the condensing coils, in order to prevent cor-rosion due to stray currents.At about 0°C is obtained the total heat recovery from the ambient air: the entire cooling capacity is supplied by the free cooling coils. When the ambient temperature drops down, the SEC.blue controller partialises even further the 2-ways valves and the fans, guaranteeing the correct thermal load management. Due to the need to maximize the air flow through the coils, is not possi-ble to combine free cooling to the “Super Silent” version.
Chiller ModeDuring the summer the air temperature is too high to exchange with the water, then the 2-way valves close the Free Cooling and the water goes directly to the evaporator. The chiller cools the water.
Mix ModeThe valves allow the passage of the water through the Free Cooling coils to exchange some heat. The rest of the heat is removed by the chiller. Due of the fact that the fans are managed first to maximize the yield of the cooling circuit, if is possible one cooling circuit is totally turned off to maximize the Free Cooling yield.
Free Cooling ModeWhen the temperature reach about 0°C the cooling capacity of the Free Cooling coils is at the maximum. The chiller is stopped and the water heat is all exchanged with the ambient air. The energy is used only to run the fans. That’s the way to reduce a lot of energy and the and operating cost.
Energy and Money saving
23
WSA Techno chillers is developed to cover an entire range of applications (from process industry to data centers). The Techno units are designed for a high energy class (Class A or B) or to work in extreme environmental conditions. They also come in very precise configurations with temperature controls dedicated to the application.
In almost all applications, the thermal load and ambient temperature conditions are highly variable. WSA Techno units closely match all environmental and load conditions, achieving a high seasonal efficiency (ESEER) – even high-er than 5. High ESEER values lead to significant energy savings.
EER - ESEER - IPLV
IPLV = 0.01 x EER100% + 0.42 x EER75% + 0.45 x EER50% + 0.12 x EER25%
IPLV: Integrated Part Load ValueThe Integrated Part Load Value (IPLV) is a performance characteristic developed by the Air-Conditioning, Heating and Refrigeration Institute (AHRI). It is most commonly used to describe the performance of a chiller capable of capacity modulation. Unlike an EER (Energy Efficiency Ratio) or COP (coefficient of per-formance), which describes the efficiency at full load conditions, the IPLV is derived from the equipment efficiency while operating at various capacities.
ESEER: European Seasonal Energy Efficiency RatioThe seasonal energy efficiency index is a parameter that indicates the seasonal efficiency of an air conditioner or a refrigerator group. The parameter is defined by the Eurovent Certification Company.
ESEER = 0.03 x EER100% + 0.33 x EER75% + 0.41 x EER50% + 0.23 x EER25%
EER: Energy Efficiency RatioThe Energy Efficiency Ratio (EER) of a particular cooling device is the ratio of output cooling energy to input electrical energy at a given operating point. EER is generally calculated using a 35°C outside air tem-perature and an inlet water temperature at 12 °C, outlet water temperature at 7°C.
EER = Cooling CapacityW7L35 / Power consuptionW7L35
Energy Efficient in every season
24
Quality
Maximum ReliabilityThe WSA Techno units are designed to guarantee the integrity during the transport both on road and in container, thanks to their sturdiness and flexibility. The components assembly is realized to ensure the maximum reliability and accessibility during the maintenance.The double refrigerant circuit with semi-hermetic screw compressors guarantees the best performance at different loads, paying particular attention to intensive uses (h24/365) and providing extra durability.
COSMOTEC QualityAll the chillers are designed and produced in compliance with:
� UNI EN ISO 9001: Quality Management System, � UNI EN ISO 14001: Environmental Management � 2006/42/EC: Machinery Directive � 2006/95/EEC: Low Voltage Directive � 2004/108/EEC: EMC Directive � 97/23/EC: Pressure Equipment Directive � EN 378-1, 2, 3, 4: Refrigerating systems and heat pumps � EN ISO 12100 -1, 2: Safety of machinery � EN ISO 13857: Safety of machinery - Safety distances � EN 60204 -1: Safety of machinery - Electrical equipment � EN 61000-6-2: Immunity for industrial environments � EN 61000-6-4: Emission standard for industrial environments
In all phases of design and production the compliance with these standards and directives are checked by an independent quality management.
Components and TestThe components installed in the COSMOTEC Techno are from well-know manufacturers, and sampling controlled at the arrival of the shipment by the Quality department.The finished chiller undergoes a function and leak tests, including:
� Visual inspection of the correct assembly � Leakage test with detector of the cooling circuits � Leakage test of hydraulic circuit � Programming and setting the electronic controller SEC.blue. � Control of the calibration of sensors and probes � Functional test and alarm check � Unit labeling, documents and complementary material
The certificate is included with the documentation pack.
Certified Value
25
PZH
H1
PSL 1
TT 1
PT 3 TCE 1
PT 1
PZH
H2
PSL 2
TT 2
PT 4
TCE 2
H
PT 2
BC
1B
C2
RL1
RU
1FG
1
VSC
1
RG
1
CO
1
M1
M2
CO
2
RG
2
VSC
2
BC
4B
C3
FG2
RU
2
RL2
WAT
ER O
UT
WAT
ER IN
TT 7 TT 4RE
SHELL & TUBES EVAPORATOR
PDZA
L 3
H
VSC
3VS
C4
MT1
0
MT1
1
MT1
2
MT1
3
MT1
4
MT1
5
MT1
6
MT1
7
PTPT
Refrigeration Circuit 8 fans
Simple, complete, efficentLegend
SYMBOL DESCRIPTION
refrigerant circuit
water circuit
signal line
lift check valve
disconnectable joint
M semihermetic screew compressor
Shell and tube heat exchanger
vessel
H manual valve disconnectable
filter
TCE electronic expansion valve
TT temperature transmitter
PZHH safety pressure cut out
PDZAL differential pressure switch
Mmotorized valve
disconnectable check valve
heat exchanger with fan
M centrifugal pump with electric motor
safety check valve
REanti freeze heater
26
PZH
H1
PSL 1
TT 1
PT 3 TCE 1
H
PT 1
PZH
H2
PSL 2
TT 2
PT 4
TCE 2
H
PT 2
RL1
RU
1FG
1
RG
1
CO
1C
O2
RG
2
FG2
RU
2
RL2
VSC
3VS
C4
WAT
ER O
UT
WAT
ER IN
TT 7 TT 4RE
SHELL & TUBES EVAPORATOR
M1
M2
PDZA
L 3
VSC
1VS
C2
BC
1B
C2
MT1
0
MT1
1
MT1
2
PT
BC
3B
C4
MT1
3
MT1
4
MT1
5
BC
5B
C6
MT1
6
MT1
7
MT1
8
PT
BC
7B
C8
MT1
9
MT2
0
MT2
1
12 fans REFRIGERANT CIRCUIT
27
PZH
H1
PSL 1
TT 1
PT 3 TCE 1
PT 1
PZH
H2
PSL 2
TT 2
PT 4
TCE 2
H
PT 2
BC
1
RL1
RU
1FG
1
VSC
1
RG
1
CO
1
M1
M2
CO
2
RG
2
VSC
2
BC
6
FG2
RU
2
RL2
WAT
ER O
UT
WAT
ER IN
TT 7 TT 4RE
SHELL & TUBES EVAPORATOR
PDZA
L 3
H
VSC
3VS
C4
BC
2
MT1
4
MT1
5
MT1
6
MT1
7
MT1
0
MT1
1
MT1
2
MT1
3
BC
3B
C4
PT
BC
7
MT2
2
MT2
3
MT2
4
MT2
5
MT1
8
MT1
9
MT2
0
MT2
1
BC
8B
C9
PT
16 fans REFRIGERANT CIRCUIT
28
PZH
H1
PSL 1
TT 1
PT 3 TCE 1
PT 1
PZH
H2
PSL 2
TT 2
PT 4
TCE 2
H
PT 2
RL1
RU
1FG
1
VSC
1
RG
1
CO
1
M1
M2
CO
2
RG
2
VSC
2
FG2
RU
2
RL2
WAT
ER O
UT
WAT
ER IN
TT 7 TT 4RE
SHELL & TUBES EVAPORATORPD
ZAL
3
H
VSC
3VS
C4
MT1
8
MT1
9
MT2
0
MT2
1
BC
5B
C6
BC
1B
C2
MT1
4
MT1
5
MT1
6
MT1
7
MT1
0
MT1
1
MT1
2
MT1
3
BC
3B
C4
PT
MT3
0
MT3
1
MT3
2
MT3
3
BC
11B
C12
BC
7B
C8
MT2
6
MT2
7
MT2
8
MT2
9
MT2
2
MT2
3
MT2
4
MT2
5
BC
9B
C10
PT
24 fans REFRIGERANT CIRCUIT
29
HH
HH
WAT
ER O
UT
WAT
ER IN
TT 7 TT 4RE
SHELL & TUBES EVAPORATOR
WAT
ER IN
M
M
TT 5
TT 3
PDZA
L 3
SC1
SC2
MT1
0
MT1
1
MT1
2
MT1
3
SC3
SC4
MT1
4
MT1
5
MT1
6
MT1
7
Free Cooling Circuit 8 fans
Energy and Money saving
30
HH
HH
HH
HH
WAT
ER O
UT
WAT
ER IN
TT 7 TT 4RE
SHELL & TUBES EVAPORATOR
WAT
ER IN
M
M
TT 5
TT 3
PDZA
L 3
SC1
SC2
MT1
3
MT1
4
MT1
5
SC3
SC4
SC5
SC6
MT1
9
MT2
0
MT2
1
MT1
6
MT1
7
MT1
8
SC7
SC8
MT1
0
MT1
1
MT1
2
12 fans FREE COOLING CIRCUIT
31
HH
HH
HH
HH
WAT
ER O
UT
WAT
ER IN
TT 7 TT 4RE
SHELL & TUBES EVAPORATOR
WAT
ER IN
M
M
TT 5
TT 3
PDZA
L 3
SC1
SC2
MT1
4
MT1
5
MT1
6
MT1
7
MT1
0
MT1
1
MT1
2
MT1
3
SC3
SC4
SC5
SC6
MT2
2
MT2
3
MT2
4
MT2
5
MT1
8
MT1
9
MT2
0
MT2
1
SC7
SC8
16 fans FREE COOLING CIRCUIT
32
HH
HH
HH
HH
HH
H
WAT
ER O
UT
WAT
ER IN
TT 7 TT 4RE
SHELL & TUBES EVAPORATOR
WAT
ER IN
M
M
TT 5
TT 3
PDZA
L 3
MT1
8
MT1
9
MT2
0
MT2
1
SC5
SC6
SC1
SC2
MT1
4
MT1
5
MT1
6
MT1
7
MT1
0
MT1
1
MT1
2
MT1
3
SC3
SC4
MT3
0
MT3
1
MT3
2
MT3
3
SC11
SC12
SC7
SC8
MT2
6
MT2
7
MT2
8
MT2
9
MT2
2
MT2
3
MT2
4
MT2
5
SC9
SC10
24 fans FREE COOLING CIRCUIT
33
Encoding
All in a readable code
Type
A Air cooled
Liquid chiller
S1046SW A 0 0 0 0A1° 2° 3° 4° 5° 6° 7° 9°
C8° 10° 11° 12° 13° 14°
Compressor
1 Standard version
2 High temperature
Version
C Chiller
DChiller with cataphoresis condensingcoils
F Free Cooling
GFree Cooling with epoxy coatedcoils
IFree Cooling with cataphoresiscoated coils
Sound level
N Standard
S Low Noise
Hydraulic circuit
0 without pump and tank
1 one pump
2 two pumps
3 one pump with inverter
4 two pumps with inverters
n° digit n° digit
Cooling Capacity
160 376 kW (1) 320 738 kW (1)
220 187 kW (1) 360 844 kW (1)
250 570 kW (1) 380 911 kW (1)
280 630 kW (1) 440 1032 kW (1)
300 672 kW (1) 480 1122 kW (1)
(1) at 50 Hz, W7L35 640 1260 kW (1)
Power supply
A 400 V / ~3 / 50 Hz
B 460 V / ~3 / 60 Hz
Heat recovery
0 None
D Economizer
T Total recovery
Option (change accordingly to the selected options)
015°
34
AB
CD
E F
H
G
-5 0 5 10 15 20 25
-40-18
+5
Working limits
DWT - Supply Water Temperature in °C, with ∆T = 5 K
AT
- E
xte
rnal
Air
Te
mp
era
ture
in °C
In Free Cooling version the minimum AT valued is set at -20°C, depending on the electronic control. WARNING: Below AT +2,5°C is advisable to use antifreeze mixture.
Ethylene glycol Propylene glycol
10% 20% 30% 40% 10% 20% 30% 40%
Freezing temperature [°C] -3,9 -8,9 -15,6 -23,4 -3,3 -7,8 -12,2 -20,6
Cooling capacity
Correction factors
0,997 0,990 0,984 0,977 0,993 0,985 0,974 0,962
Input power 0,999 0,997 0,996 0,994 0,999 0,996 0,993 0,989
Water flow 1,014 1,033 1,068 1,117 0,989 1,009 1,017 1,040
Pressure drop water side 1,07 1,16 1,30 1,48 1,04 1,14 1,23 1,37
Multiply the correction factor in this table for the value in Data Sheet
Correction Factors
Wide applicationAT VALUES [°C]
A B C D E F G H
BA
SE
WSA160 50 55 52 55 -6 -10 -10 48
WSA220 46 53 50 53 -10 -10 -10 44
WSA250 51 56 53 55 -4 -10 -10 49
WSA280 49 55 52 54 -6 -10 -10 47
WSA300 47 54 51 53 -8 -10 -10 45
WSA320 51 56 53 55 -6 -10 -10 49
WSA360 48 54 51 54 -8 -10 -10 46
WSA380 47 54 51 53 -7 -10 -10 45
WSA440 45 52 49 52 -10 -10 -10 42
WSA480 50 56 53 55 -5 -10 -10 48
WSA640 - - 51 54 -10 -10 - 45
LOW
NO
ISE
WSA160 44 51 48 50 -6 -10 -10 44
WSA220 39 47 45 48 -10 -10 -10 37
WSA250 45 52 49 51 -4 -10 -10 43
WSA280 42 50 48 50 -6 -10 -10 41
WSA300 39 48 46 48 -8 -10 -10 38
WSA320 44 52 48 51 -6 -10 -10 40
WSA360 41 50 47 49 -8 -10 -10 39
WSA380 39 49 46 49 -7 -10 -10 37
WSA440 36 46 44 47 -10 -10 -10 35
WSA480 44 52 48 51 -5 -10 -10 42
WSA640 - - 45 50 -10 -10 - 37
FRE
E C
OO
LIN
G
WSA160 47 53 49 53 -6 -10 -10 45
WSA220 43 50 47 50 -10 -10 -10 41
WSA250 48 54 51 53 -4 -10 -10 45
WSA280 46 53 50 52 -6 -10 -10 43
WSA300 43 51 48 51 -8 -10 -10 42
WSA320 47 54 51 53 -6 -10 -10 45
WSA360 44 52 49 51 -8 -10 -10 43
WSA380 43 52 49 51 -7 -10 -10 41
WSA440 41 49 46 49 -10 -10 -10 39
WSA480 47 54 50 53 -5 -10 -10 45
WSA640 - - 49 50 -10 -10 - 42
Special request
Standard Version
Standar Version + heating elements + glycol
Standar Version + heating elements + glycol + wind stop
Low temperature version (LT)
LT version + heating elements + glycol
LT version + heating elements + glycol + wind stop
High temperature version (HT)
HT version + heating elements + glycol
HT version + heating elements + glycol + wind stop
35
1,0m
1,3m 1,3m
2,6m 2,6m
1,35m
1,0m2,7m
1,3m1,3m
1,3m
1,3m
5 m
1,35
m
1,0m
Minimum distance from obstacles
Distance of installation of several units
Free space
Few space, more capacity
36
50,0
60,0
70,0
80,0
90,0
100,0
110,0
WSA160 WSA220 WSA280 WSA250 WSA300-320 WSA360-380 WSA440 WSA480-640
0,0
10,0
20,0
30,0
40,0
0,0 25,0 50,0 75,0 100,0 125,0 150,0 175,0 200,0 225,0 250,0 275,0 300,0 325,0
WSA
160
WSA
220
WSA
250
WSA
280
WSA
300-
320
WSA360-3
80
WSA480-6
40
WSA440
90,0
100,0
110,0
120,0
130,0
140,0
150,0
160,0
170,0
180,0WSA160 WSA220 WSA250 WSA280 WSA300 WSA320 WSA360 WSA380 WSA440 WSA480 WSA640
20,0
30,0
40,0
50,0
60,0
70,0
80,0
0,0 25,0 50,0 75,0 100,0 125,0 150,0 175,0 200,0 225,0 250,0 275,0 300,0 325,0
WSA
160
WSA
220
WSA25
0
WSA
280
WSA300
WSA320
WSA360WSA380
WSA640
WSA480
WSA440
Pressure drop on the Evaporator
Pressure drop on the Evaporator + Free Cooling circuit
Pumps curves
High performance
Water Flow [m³/h]
Pres
sure
dro
p [k
Pa]
Water Flow [m³/h]
Pres
sure
dro
p [k
Pa]
37
200
225
250
275
300
325
350
375
50
75
100
125
150
175
50 75 100 125 150 175 200 225 250 275 300 325
WSA280
WSA250
WSA300
WSA320
WSA380
WSA360
WSA440WSA480
WSA640
275
300
325
350
375
400
425
450
475
100
125
150
175
200
225
250
50 75 100 125 150 175 200 225 250 275 300 325
WSA250
WSA280
WSA300WSA320
WSA360
WSA380
WSA440
WSA480
1 or 2 pumps (option): net residual head - Standar version
1 or 2 pumps (option): net residual head - HT version
PUMPS CURVES
Water Flow [m³/h]
Hea
d pr
essu
re [k
Pa]
Water Flow [m³/h]
Hea
d pr
essu
re [k
Pa]
38
150
175
200
225
250
275
300
325
350
0
25
50
75
100
125
150
50 75 100 125 150 175 200 225 250 275 300 325
WSA250-280
WSA300
WSA320
WSA360
WSA380
WSA440
WSA640
WSA480
225
250
275
300
325
350
375
400
425
450
475
500
25
50
75
100
125
150
175
200
225
50 75 100 125 150 175 200 225 250 275 300 325
WSA440W
SA250
WSA280
WSA300
WSA320
WSA380
WSA360
WSA480
1 or 2 pumps (option): net residual head - Free Cooling version
1 or 2 pumps (option): net residual head - Free Cooling HT version
PUMPS CURVES
Water Flow [m³/h]
Hea
d pr
essu
re [k
Pa]
Water Flow [m³/h]
Hea
d pr
essu
re [k
Pa]
39
Technical data
Wide range
WSA 160 WSA 220
Standard Low Noise Free Cooling Standard Low Noise Free Cooling
Cooling capacity kW 376 360 366 482 442 469
Cooling capacity in free cooling kW n.a. n.a. 376 n.a. n.a. 472
Total power consumpion kW 121 122 126 164 175 172
Sound power level dB(A) 96,9 89,0 96,9 98,5 90,5 98,5
Sound pressure level @ 10m dB(A) 68,9 61,0 68,9 70,5 62,5 70,5
Chilled water circuit
Flow of fluid to be cooled m³/h 64 62 64,4 83 76 82,7
Pressure drop on fluid to be cooled side kPa 44 32 44 35 33 34,75
Refrigerant Circuit
Refrigerant R134a R134a
Refrigerant charge (per circuit) kg 67 + 67 86 +86
No. of refrigerant circuits 2 2
Oil charge dm³ 22 + 22 22 + 22
Compressor
No. 2 x Semi-Hermetic Double Screw 2 x Semi-Hermetic Double Screw
Capacity control % 12,5 ... 100 12,5 ... 100
Power Consumption kW 105 105 110 148 148 156
Current consumption A 34,4 20 34,4 243 243 253,9
Maximum current consumption A 288 288 288 364 364 364
Fans
No. 8 x Ø 800 mm Axial 8 x Ø 800 mm Axial
Air flow with free outlet m³/h 148820 111280 122250 144240 99570 120127
Power consumption kW 17,6 17,6 17,6 17,6 17,6 17,6
Current consumption A 37,8 37,8 37,8 37,8 37,8 37,8
Unit data
Rated power supply V/-/Hz 400 / 3 / 50 400 / 3 / 50
Maximum current consumption A 336 336 336 412 412 412
Inrush current A 586 586 586 750 750 750
Height x Width x Depth mm 2473 x 2278 x 4240 2473 x 2278 x 4635
Weight for transport kg 4898 4898 5748 5043 5043 5973
Weight in operation kg 5092 5092 5768 5226 5226 6354
Efficiency index
EER 3,1 2,94 2,91 2,94 2,52 2,72
ESEER 4,43 4,59 4,33 4,65 4,64 4,39
IPLV 4,35 4,63 4,23 4,55 4,57 4,43
� Evaporator water (in/out) 12/7 °C; Condenser air (in) 35 °C � Average sound pressure level, at 10m distance, unit in a free field on a
reflective surface. � Unit at full capacity. According to ISO 3744. Pumps contribution is not
considered. � In case of appications with output fluid temperature below 0°C, please
contact the manufacturer � Weight of Standard Version @ 50Hz, without pump, without other options
40
TECHNICAL DATA
WSA 250 WSA 280
Standard Low Noise Free Cooling Standard Low Noise Free Cooling
Cooling capacity kW 568 534 552 631 589 594
Cooling capacity in free cooling kW n.a. n.a. 552 n.a. n.a. 611
Total power consumpion kW 178 183 185 203 212 212
Sound power level dB(A) 97,2 89,4 97,2 97,6 89,7 97,6
Sound pressure level @ 10m dB(A) 69,2 61,4 69,2 69,6 61,7 69,6
Chilled water circuit
Flow of fluid to be cooled m³/h 97 92 97,4 108 101 108,2
Pressure drop on fluid to be cooled side kPa 36 31 35,56 38 37 38,25
Refrigerant Circuit
Refrigerant R134a R134a
Refrigerant charge (per circuit) kg 101 + 101 112 + 112
No. of refrigerant circuits 2 2
Oil charge dm³ 19 + 19 19 + 19
Compressor
No. 2 x Semi-Hermetic Double Screw 2 x Semi-Hermetic Double Screw
Capacity control % 12,5 ... 100 12,5 ... 100
Power Consumption kW 154 154 161 179 179 187
Current consumption A 51,6 30 51,6 51,6 30 51,6
Maximum current consumption A 240 240 240 428 428 428
Fans
No. 12 x Ø 800 mm Axial 12 x Ø 800 mm Axial
Air flow with free outlet m³/h 215045 147655 177851 215045 147655 177851
Power consumption kW 26,4 26,4 26,4 26,4 26,4 26,4
Current consumption A 56,8 56,8 56,8 56,8 56,8 56,8
Unit data
Rated power supply V/-/Hz 400 / 3 / 50 400 / 3 / 50
Maximum current consumption A 459 459 459 495 495 495
Inrush current A 875 875 875 946 946 946
Height x Width x Depth mm 2473 x 2278 x 6960 2473 x 2278 x 6960
Weight for transport kg 6251 6251 7786 6285 6285 7821
Weight in operation kg 6549 6549 8371 6583 6583 8406
Efficiency index
EER 3,18 2,91 2,99 3,11 2,77 2,81
ESEER 4,52 4,65 4,5 4,58 4,66 4,39
IPLV 4,48 4,7 4,35 4,58 4,71 4,3
� Evaporator water (in/out) 12/7 °C; Condenser air (in) 35 °C � Average sound pressure level, at 10m distance, unit in a free field on a
reflective surface. � Unit at full capacity. According to ISO 3744. Pumps contribution is not
considered. � In case of appications with output fluid temperature below 0°C, please
contact the manufacturer � Weight of Standard Version @ 50Hz, without pump, without other options
41
TECHNICAL DATA
WSA 300 WSA 320
Standard Low Noise Free Cooling Standard Low Noise Free Cooling
Cooling capacity kW 673 627 652 739 689 721
Cooling capacity in free cooling kW -- -- 660 -- -- 740
Total power consumpion kW 226 239 237 237 245 247
Sound power level dB(A) 97,6 89,7 97,6 98,6 90,7 98,6
Sound pressure level @ 10m dB(A) 69,6 61,7 69,6 70,6 62,8 70,6
Chilled water circuit
Flow of fluid to be cooled m³/h 115 107 115,4 127 118 126,8
Pressure drop on fluid to be cooled side kPa 35 28 35,4 43 33 42,77
Refrigerant Circuit
Refrigerant R134a R134a
Refrigerant charge (per circuit) kg 119 + 119 131 + 131
No. of refrigerant circuits 2 2
Oil charge dm³ 19 + 19 30 + 30
Compressor
No. 2 x Semi-Hermetic Double Screw 2 x Semi-Hermetic Double Screw
Capacity control % 12,5 ... 100 12,5 ... 100
Power Consumption kW 202 202 212 205 205 215
Current consumption A 51,6 30 51,6 68,8 40 68,8
Maximum current consumption A 428 428 428 560 560 560
Fans
No. 12 x Ø 800 mm Axial 16 x Ø 800 mm Axial
Air flow with free outlet m³/h 215045 147655 177851 278715 186770 224542
Power consumption kW 26,4 26,4 26,4 35,2 35,2 35,2
Current consumption A 56,8 56,8 56,8 75,7 75,7 75,7
Unit data
Rated power supply V/-/Hz 400 / 3 / 50 400 / 3 / 50
Maximum current consumption A 495 495 495 646 646 646
Inrush current A 946 946 946 802 802 802
Height x Width x Depth mm 2473 x 2278 x 6960 2473 x 2278 x 8080
Weight for transport kg 6379 6379 7914 7637 7637 9333
Weight in operation kg 6419 6419 8491 7926 7926 9976
Efficiency index
EER 2,97 2,61 2,76 3,12 2,81 2,92
ESEER 4,45 4,49 4,34 4,53 4,64 4,44
IPLV 4,45 4,52 4,29 4,37 4,57 4,28
� Evaporator water (in/out) 12/7 °C; Condenser air (in) 35 °C � Average sound pressure level, at 10m distance, unit in a free field on a
reflective surface. � Unit at full capacity. According to ISO 3744. Pumps contribution is not
considered. � In case of appications with output fluid temperature below 0°C, please
contact the manufacturer � Weight of Standard Version @ 50Hz, without pump, without other options
42
TECHNICAL DATA
WSA 360 WSA 380
Standard Low Noise Free Cooling Standard Low Noise Free Cooling
Cooling capacity kW 845 780 822 912 851 888
Cooling capacity in free cooling kW -- -- 835 -- -- 879
Total power consumpion kW 271 283 283 294 307 306
Sound power level dB(A) 98,8 90,9 98,8 98,8 90,9 98,8
Sound pressure level @ 10m dB(A) 70,8 62,9 70,8 70,8 62,9 70,8
Chilled water circuit
Flow of fluid to be cooled m³/h 145 134 145 156 146 156,4
Pressure drop on fluid to be cooled side kPa 32 28 32,24 38 36 38,07
Refrigerant Circuit
Refrigerant R134a R134a
Refrigerant charge (per circuit) kg 149 + 149 161 + 161
No. of refrigerant circuits 2 2
Oil charge dm³ 30 + 30 30 + 30
Compressor
No. 2 x Semi-Hermetic Double Screw 2 x Semi-Hermetic Double Screw
Capacity control % 12,5 ... 100 12,5 ... 100
Power Consumption kW 239 239 251 262 262 273
Current consumption A 68,8 40 68,8 68,8 40 68,8
Maximum current consumption A 620 620 620 620 620 620
Fans
No. 16 x Ø 800 mm Axial 16 x Ø 800 mm Axial
Air flow with free outlet m³/h 278715 186770 224542 288480 199135 240253
Power consumption kW 35,2 35,2 35,2 35,2 35,2 35,2
Current consumption A 75,7 75,7 75,7 75,7 75,7 75,7
Unit data
Rated power supply V/-/Hz 400 / 3 / 50 400 / 3 / 50
Maximum current consumption A 706 706 706 706 706 706
Inrush current A 861 861 861 861 861 861
Height x Width x Depth mm 2473 x 2278 x 8080 2473 x 2278 x 8080
Weight for transport kg 7921 7921 9618 8212 8212 10068
Weight in operation kg 8413 8413 10464 8704 8704 10958
Efficiency index
EER 3,12 2,75 2,91 3,1 2,77 2,91
ESEER 4,76 4,78 4,55 4,65 4,67 4,41
IPLV 4,6 4,68 4,46 4,56 4,65 4,42
� Evaporator water (in/out) 12/7 °C; Condenser air (in) 35 °C � Average sound pressure level, at 10m distance, unit in a free field on a
reflective surface. � Unit at full capacity. According to ISO 3744. Pumps contribution is not
considered. � In case of appications with output fluid temperature below 0°C, please
contact the manufacturer � Weight of Standard Version @ 50Hz, without pump, without other options
43
TECHNICAL DATA
WSA 440 WSA 480
Standard Low Noise Free Cooling Standard Low Noise Free Cooling
Cooling capacity kW 1032 958 1004 1122 1053 1088
Cooling capacity in free cooling kW -- -- 1004 -- -- 1100
Total power consumpion kW 354 379 370 351 363 366
Sound power level dB(A) 99,7 91,8 99,7 100,6 92,7 100,6
Sound pressure level @ 10m dB(A) 71,7 63,8 71,7 72,6 64,7 72,6
Chilled water circuit
Flow of fluid to be cooled m³/h 177 164 177,1 193 181 192,5
Pressure drop on fluid to be cooled side kPa 32 42 31,99 41 181 40,68
Refrigerant Circuit
Refrigerant R134a R134a
Refrigerant charge (per circuit) kg 183 + 183 198 + 198
No. of refrigerant circuits 2 2
Oil charge dm³ 30 + 30 30 + 30
Compressor
No. 2 x Semi-Hermetic Double Screw 2 x Semi-Hermetic Double Screw
Capacity control % 12,5 ... 100 12,5 ... 100
Power Consumption kW 322 322 337 303 303 318
Current consumption A 68,8 40 68,8 103 60 103
Maximum current consumption A 640 640 640 720 720 720
Fans
No. 16 x Ø 800 mm Axial 24 x Ø 800 mm Axial
Air flow with free outlet m³/h 288480 199135 240253 418070 280155 336812
Power consumption kW 35,2 35,2 35,2 52,8 52,8 52,8
Current consumption A 75,7 75,7 75,7 113,5 113,5 113,5
Unit data
Rated power supply V/-/Hz 400 / 3 / 50 400 / 3 / 50
Maximum current consumption A 726 726 726 844 844 844
Inrush current A 992 992 992 1134 1134 1134
Height x Width x Depth mm 2473 x 2278 x 8080 2473 x 2278 x 11920
Weight for transport kg 8532 8532 10390 9799 9799 12045
Weight in operation kg 8983 8983 11239 10250 10250 13027
Efficiency index
EER 2,91 2,52 2,72 3,19 2,9 2,97
ESEER 4,66 4,59 4,3 4,64 4,72 4,49
IPLV 4,55 4,53 4,41 4,47 4,67 4,32
� Evaporator water (in/out) 12/7 °C; Condenser air (in) 35 °C � Average sound pressure level, at 10m distance, unit in a free field on a
reflective surface. � Unit at full capacity. According to ISO 3744. Pumps contribution is not
considered. � In case of appications with output fluid temperature below 0°C, please
contact the manufacturer � Weight of Standard Version @ 50Hz, without pump, without other options
44
TECHNICAL DATA
� Evaporator water (in/out) 12/7 °C; Condenser air (in) 35 °C � Average sound pressure level, at 10m distance, unit in a free field on a
reflective surface. � Unit at full capacity. According to ISO 3744. Pumps contribution is not
considered. � In case of appications with output fluid temperature below 0°C, please
contact the manufacturer � Weight of Standard Version @ 50Hz, without pump, without other options
WSA640
Standard Low Noise Free Cooling
Cooling capacity kW 1260 1167 1225
Cooling capacity in free cooling kW -- -- 1237
Total power consumpion kW 431 453 451
Sound power level dB(A) 102,0 94,1 102,0
Sound pressure level @ 10m dB(A) 74,0 66,1 74,0
Chilled water circuit
Flow of fluid to be cooled m³/h 216 200 216,2
Pressure drop on fluid to be cooled side kPa 49 200 49,2
Refrigerant Circuit
Refrigerant R134a
Refrigerant charge (per circuit) kg 223 + 223
No. of refrigerant circuits 2
Oil charge dm³ 32 + 32
Compressor
No. 2 x Semi-Hermetic Double Screw
Capacity control % 12,5 ... 100
Power Consumption kW 383 383 403
Current consumption A 103 60 103
Maximum current consumption A 894 894 894
Fans
No. 24 x Ø 800 mm Axial
Air flow with free outlet m³/h 418070 280155 336812
Power consumption kW 52,8 52,8 52,8
Current consumption A 113,5 113,5 113,5
Unit data
Rated power supply V/-/Hz 400 / 3 / 50
Maximum current consumption A 1018 1018 1018
Inrush current A 1488 1488 1488
Height x Width x Depth mm 2473 x 2278 x 11920
Weight for transport kg 10100 10100 12346
Weight in operation kg 10551 10551 13328
Efficiency index
EER 2,92 2,57 2,72
ESEER 4,53 4,53 4,4
IPLV 4,48 4,52 4,32
45
STULZ S.p.A.via E. Torricelli, 337067 Valeggio s/Mincio (VR)Tel. +39 045 6331600Fax. +39 045 [email protected] - www.cosmotec.it
ST
UL
Z S
.p.A
. re
serv
es
the
rig
ht to
up
dat
e c
hara
cte
ristic
s an
d d
ata
with
ou
t no
tice
.A
ny m
od
ifica
tion
or p
rint e
rro
r wo
n't e
ntitl
e th
e r
ead
er t
o d
isp
ute
s