  • 8/10/2019 W_Regulations.pdf

    1/11

    Rules and Regulations

    The U.S. Coast Guard is statutorily charged with administering maritime safety on behalf of

    the people of the United States. In carrying out this function, the Coast Guard monitors safety

    aspects of commercial vessels from design stages throughout the vessel's useful life. Often

    design standards such as those developed by the American Bureau of Shipping are used.

    Codes are referenced directly by the U.S. Code of Federal Regulations (CFR) [6-1]. Other

    countries, such as England, France, Germany, Norway, Italy and Japan have their own

    standards that are analogous to those developed by ABS. Treatment of FRP materials is

    handled differently by each country. This section will only describe the U.S. agencies.

    U.S. Coast Guard

    The Coast Guard operates on both a local and national level to accomplish their mission. On

    the local level, 42 Marine Safety Offices (MSOs) are located throughout the country. These

    offices are responsible for inspecting vessels during construction, inspecting existing vessels,

    licensing personnel and investigating accidents. The Office of Marine Safety, Security and

    Environment Protection is located in Washington, DC. This office primarily disseminates

    policy, directs marine safety training, oversees port security and responds to the environmental

    needs of the country. The Marine Safety Center, also located in Washington, is the office

    where vessel plans are reviewed. The Coast Guard's technical staff reviews machinery,

    electrical arrangement, structural and stability plans, calculations and instructions for new

    construction and conversions for approximately 18,000 vessels a year.

    The Coast Guard has authorized ABS for plan review of certain types of vessels. These do not

    include Subchapter T vessels and novel craft. The following section will attempt to describe

    the various classifications of vessels, as defined in the CFR. Table 6-1 summarizes some of

    these designations. Structural requirements for each class of vessel will also be highlighted.

    Subchapter C - Uninspected VesselsThe CFR regulations that cover uninspected vessels are primarily concerned with safety, rather

    than structural items. The areas covered include:

    Life preservers and other lifesaving equipment;

    Emergency position indicating radio beacons (fishing vessels);

    Fire extinguishing equipment;

    Backfire flame control;

    Ventilation; Cooking, heating and lighting systems; and

    Garbage retention.

    309

    Chapter Six REFERENCE

  • 8/10/2019 W_Regulations.pdf

    2/11

    Organizations that are cited for reference:

    American Boat and Yacht Council

    3069 Solomon's Island Road

    Edgewater, MD 21037

    410-956-1050 / FAX 410-956-2737

    National Fire Protection Association (NFPA)

    1 Batterymarch Park

    Quincy, MA 02269-9101 USA

    617-770-3000 / FAX 617-770-0700

    http://www.nfpa.org/

    Table 6-1 Summary of CFR Vessel Classifications [46 CFR, Part 2.01 - 7(a)]

    Size or OtherLimitations

    SubchapterH -Passenger

    Subchapter T -SmallPassenger

    Subchapter K- SmallPassenger

    Subchapter ICargo andMiscellaneous

    SubchapterCUninspected

    46 CFR, Parts70-80

    46 CFR, Part 17546 CFR, Part114

    46 CFR, Parts90-106

    46 CFR, Parts24-26

    Vesselsover 15gross tonsexceptseagoingmotorvessels of300 grosstons andover.Seagoing motorvessels of300 grosstons andover.

    Vessels over100 gross tons

    Under 100 grosstons

    All vesselscarrying morethan 150passengers orwith overnight

    accommodationsfor more than 49passengers

    All vesselscarrying freightfor hire except

    those coveredby H or Tvessels

    All vesselsexcept thosecovered by H,T, K or Ivessels

    All othervessels of over65 feet inlength carryingpassengers forhire.

    All vesselscarrying morethan 12 andless than 150passengers onan internationalvoyage, exceptyachts.

    All vessels notover 65 feet inlength which

    carry more than6 passengers.

    All other vessels carryingpassengers except yachts.

    Subchapter K'refers to vesselswith 151passengers or 61 meters (200feet)

    Vesselsnot over700 grosstons.

    Vessels over100 gross tons

    Vessels under 100gross tons

    Not applicableAll vessels carrying more than 6passengers.

    Vesselsover 700gross tons.

    All vessels carrying passengers forhire.

    Subchapter H - Passenger Vessels

    Part 72 of CFR 46 is titled Construction and Arrangement. Subpart 72.01-15 Structural

    Standards states:

    310

    Rules and Regulations Marine Composites

  • 8/10/2019 W_Regulations.pdf

    3/11

    In general, compliance with the standards established by ABS will be considered

    satisfactory evidence of structural efficiency of the vessel. However, in special

    cases, a detailed analysis of the entire structure or some integral part may be

    made by the Coast Guard to determine the structural requirements.

    Looking at Subpart 72.05 - Structural Fire Protection, under 72.05-10 Type, location andconstruction of fire control bulkheads and decks, it is noted:

    The hull, structural bulkheads, decks, and deckhouses shall be constructed of

    steel or other equivalent metal construction of appropriate scantlings.

    The section goes on to define different types of bulkheads, based fire performance.

    Subchapter I - Cargo and Miscellaneous Vessels

    The requirements for I vessels is slightly different than for H. Under Subpart 92.07 -

    Structural Fire Protection, 92.07-10 Construction states:

    The hull, superstructure, structural bulkheads, decks and deckhouses shall be

    constructed of steel. Alternately, the Commandant may permit the use of other

    suitable materials in special cases, having in mind the risk of fire.

    Subchapter T - Small Passenger Vessels177.300 Structural Design

    Except as otherwise noted by this subpart, a vessel must comply with the structural design

    requirements of one of the standards listed below for the hull material of the vessel.

    (c) Fiber reinforced plastic vessels:

    (1) Rules and Regulations for the Classification of Yachts and Small Craft,

    Lloyd's; or

    (2) Rules for building and Classing Reinforced Plastic Vessels, ABS

    177.405 General arrangement and outfitting

    (a) The general construction of the vessel shall be such as to minimize fire

    hazards insofar as reasonable and practicable. .

    177.410 Structural fire protection.

    (a)Cooking areas. Vertical or horizontal surfaces within 910 millimeters (3 feet) of cooking

    appliances must have an American Society for Testing and Materials (ASTM) E-84 Surface

    Burning Characteristics of Building Materials flame spread rating of not more than 75.Curtains, draperies, or free hanging fabrics must not be fitted within 910 millimeters (3 feet) of

    cooking or heating appliances.

    (b) Fiber reinforced plastic.. When the hull, decks, deckhouse, or superstructure of a vessel is

    partially or completely constructed of fiber reinforced plastic, including composite construction,

    the resin used must have an ASTM E-84 flame spread rating of not more than 100.

    311

    Chapter Six REFERENCE

  • 8/10/2019 W_Regulations.pdf

    4/11

    (c)Use of general purpose resin - General purpose resins may be used in lieu of those having

    an ASTM E 84 flame spread rating of not more than 100 provided that the following additional

    requirements are met:

    (1) Cooking and Heating Appliances - Galleys must be surrounded by B-15

    Class fire boundaries. This may not apply to concession stands that are notconsidered high fire hazards areas (galleys) as long as they do not contain

    medium to high heat appliances such as deep fat fryers, flat plate type grilles,

    and open ranges with heating surfaces exceeding 121C (250F). Open flame

    systems for cooking and heating are not allowed.

    (2) Sources of Ignition - Electrical equipment and switch boards must be

    protected from fuel or water sources. Fuel lines and hoses must be located as

    far as practical from heat sources. Internal combustion engine exhausts, boiler

    and galley uptakes, and similar sources of ignition must be kept clear of and

    suitability insulated from any woodwork or other combustible matter. Internal

    combustion engine dry exhaust systems must be installed in accordance withABYC Standard P-1.

    (3)Fire Detection and Extinguishing Systems - Fire detection and extinguishing

    systems must be installed in compliance with 181.400 through 181.420 of this

    chapter. Additionally, all fiber reinforced plastic (FRP) vessels constructed with

    general purpose resins must be fitted with a smoke activated fire detection

    system of an approved type, installed in accordance with 76.27 in subchapter H

    of this chapter, in all accommodation spaces, all service spaces, and in isolated

    spaces such as voids and storage lockers that contain an ignition source such as

    electric equipment or piping for a dry exhaust system.

    (4) Machinery Space Boundaries - Boundaries that separate machinery spaces

    from accommodation spaces, service spaces, and control spaces must be lined

    with noncombustible panels or insulation approved in accordance with 164.009

    in subchapter Q of this chapter, or other standard specified by the Commandant.

    (5) Furnishings - Furniture and furnishings must comply with 116.423 in

    subchapter K of this chapter.

    (d)Limitations on the use of general purpose resin.

    (1) Overnight Accommodations - Vessels with overnight passengeraccommodations must not be constructed with general purpose resin.

    (2) Gasoline Fuel Systems - Vessels with engines powered by gasoline or other

    fuels having a flash point of 43.3 C (110 F) or lower must not be constructed

    with general purpose resin, except for vessels powered by outboard engines with

    portable fuel tanks stored in an open area aft, if, as determined by the cognizant

    OCMI, the arrangement does not produce an unreasonable hazard.

    312

    Rules and Regulations Marine Composites

  • 8/10/2019 W_Regulations.pdf

    5/11

    (3)Cargo - Vessels carrying or intended to carry hazardous combustible or

    flammable cargo must not be constructed with general purpose resin.

    Subchapter K - Small Passenger Vessels

    Subpart C - Hull Structure

    116.300 Structural Design provides for steel or aluminum hulls only with alternate design

    considerations based on engineering principles that show that the vessel structure provides

    adequate safety and strength. Of major concern to the U.S. Coast Guard would be the added

    fire threat of a composite hull. The IMO High-Speed Craft Code (see Fire Testing section)

    may form the basis for an alternative acceptable criteria.

    Subpart D - Fire Protection

    116.400 Application.

    (a) This subpart applies to:

    (1) Vessels carrying more than 150 passengers; or

    (2) Vessels with overnight accommodations for more than 49 passengers but not

    more than 150 passengers.

    (b) A vessel with overnight accommodations for more than 150 passengers must comply with

    72.05 in subchapter H of this chapter.

    116.405 General arrangement and outfitting.

    (a) Fire hazards to be minimized. The general construction of the vessel must be such as to

    minimize fire hazards insofar as it is reasonable and practicable.

    (b) Combustible materials to be limited. Limited amounts of combustible materials such as

    wiring insulation, pipe hanger linings, nonmetallic (plastic) pipe, and cable ties are permitted in

    concealed spaces except as otherwise prohibited by this subpart.

    (c) Combustibles insulated from heated surfaces. Internal combustion engine exhausts, boiler

    and galley uptakes, and similar sources of ignition must be kept clear of and suitably insulated

    from combustible material.

    (d) Separation of machinery and fuel tank spaces from accommodation spaces. Machineryand fuel tank spaces must be separated from accommodation spaces by boundaries that prevent

    the passage of vapors.

    (e) Paint and flammable liquid lockers. Paint and flammable liquid lockers must be

    constructed of steel or equivalent material, or wholly lined with steel or equivalent material.

    313

    Chapter Six REFERENCE

  • 8/10/2019 W_Regulations.pdf

    6/11

    (f) Nonmetallic piping in concealed spaces. The use of short runs of nonmetallic (plastic)

    pipe within a concealed spaces in a control space, accommodation space, or service space is

    permitted in nonvital service only, provided it is not used to carry flammable liquids (including

    liquors of 80 proof or higher) and:

    (1) Has flame spread rating of not more than 20 and a smoke developed ratingof not more than 50 when filled with water and tested in accordance with

    American Society for Testing and Materials (ASTM E 84 Test for Surface

    Burning Characteristics of Building Materials, ) or Underwriters Laboratories

    (UL) 723 Test for Surface Burning Characteristics of Building Materials, by

    an independent laboratory; or

    (2) Has a flame spread rating of not more than 20 and a smoke developed

    rating of not more than 130 when empty and tested in accordance with ASTM E

    84 or UL 723 by an independent laboratory

    (g) Vapor barriers.

    Vapor barriers must be provided where insulation of any type is used inspaces where flammable and combustible liquids or vapors are present, such as machinery

    spaces and paint lockers.

    (h) Interior finishes. Combustible interior finishes allowed by 116.422 (d) of this part must

    not extend into hidden spaces, such as behind linings, above ceilings, or between bulkheads.

    (i) Waste Receptacles. Unless other means are provided to ensure that a potential waste

    receptacle fire would be limited to the receptacle, waste receptacles must be constructed of

    noncombustible materials with no openings in the sides or bottom.

    (f) Mattresses. All mattresses must comply with either:

    (1) The U.S. Department of Commerce Standard for Mattress Flammability (FF

    4-72.16), 16 CFR Part 1632, Subpart A and not contain polyurethane foam; or

    (2) International Maritime Organization Resolution A.688(17) Fire Test

    Procedures For Ignitability of Bedding Components. Mattresses that are tested

    to this standard may contain polyurethane foam.

    116.415 Fire control boundaries.

    (a) Type and construction of fire control bulkheads and decks.

    (1) Major hull structure - The hull, structural bulkheads, columns and

    stanchions, superstructures, and deckhouses must be composed of steel or

    equivalent material, except that where C'-Class construction is permitted by

    Tables 116.415 (b) and (c), bulkheads and decks may be constructed of

    approved noncombustible materials.

    314

    Rules and Regulations Marine Composites

  • 8/10/2019 W_Regulations.pdf

    7/11

    (2) Bulkheads and decks - Bulkheads and decks must be classed as A-60,

    A-30, A-15, A-0, B-15, B-0, C, or C' based on the following:

    (i) A-Class bulkheads or decks must be composed of steel or equivalent

    material, suitably stiffened and made intact with the main structure of the vessel,

    such as the shell, structural bulkheads, and decks. They must be so constructedthat, if subjected to the standard fire test, they are capable of preventing the

    passage of smoke and flame for one hour. In addition, they must be so insulated

    with approved structural insulation, bulkhead panels, or deck covering so that, if

    subjected to the standard fire test for the applicable time period listed below, the

    average temperature on the unexposed side does not rise more than 139C

    (250F) above the original temperature, nor does the temperature at any one

    point, including any joint, rise more than 181C (325F) above the original

    temperature:

    A-60 Class 60 minutes

    A-30 Class 30 minutes A-15 Class 15 minutes

    A-0 Class 0 minutes

    (ii) Penetrations in A-Class fire control boundaries for electrical cables, pipes, trunks, ducts,

    etc. must be constructed to prevent the passage of flame and smoke for one hour. In addition,

    the penetration must be designed or insulated so that it will withstand the same temperature rise

    limits as the boundary penetrated.

    (iii) B-Class bulkheads and decks must be constructed of noncombustible materials and made

    intact with the main structure of the vessel, such as shell, structural bulkheads, and decks,

    except that a B-Class bulkhead need not extend above an approved continuous B-Class ceiling.They must be so constructed that, if subjected to the standard fire test, they are capable of

    preventing the passage of flame for 30 minutes. In addition, their insulation value must be

    such that, if subjected to the standard fire test for the applicable time period listed below, the

    average temperature of the unexposed side does not rise more than 139C (250F) above the

    original temperature, nor does the temperature at any one point, including any joint, rise more

    than 225 C (405 F) above the original temperature:

    B-15 Class 15 minutes

    B-0 Class 0 minutes

    (iv) Penetrations in B-Class fire control boundaries for electrical cables, pipes, trunks, ducts,

    etc. must be constructed to prevent the passage of flame for 30 minutes. In addition, the

    penetration must be designed or insulated so that it will withstand the same temperature rise

    limits as the boundary penetrated.

    (v) C-Class bulkheads and decks must be composed of noncombustible materials.

    315

    Chapter Six REFERENCE

  • 8/10/2019 W_Regulations.pdf

    8/11

    (vi) C'-Class bulkheads and decks must be constructed of noncombustible materials and

    made intact with the main structure of the vessel, such as shell, structural bulkheads, and decks,

    except that a C'-Class bulkhead need not extend above a continuous B-Class or C'-Class

    ceiling. C'-Class bulkheads must be constructed to prevent the passage of smoke between

    adjacent areas. Penetrations in C'-Class boundaries for electrical cables, pipes, trunks, ducts,

    etc. must be constructed so as to preserve the smoke-tight integrity of the boundary.

    (vii) Any sheathing, furring, or holding pieces incidental to the securing of structural

    insulation must be an approved noncombustible material.

    (b) Bulkhead requirements. Bulkheads between various spaces must meet the requirements of

    Table 116.415(b).

    (c) Deck requirements. Decks between various spaces must meet the requirements of Table

    116.415(c), except that where linings or bulkhead panels are framed away from the shell or

    structural bulkheads, the deck within the void space so formed need only meet A-0 Class

    requirements.

    (d) Main vertical zones.

    (1) The hull, superstructure, and deck houses of a vessel, except for a vehicle space on a

    vehicle ferry, must be subdivided by bulkheads into main vertical zones which:

    (i) Are generally not more than 40 meters (131 feet) in mean length on any one deck;

    (ii) Must be constructed to:

    (A) The greater of A-30 Class or the requirements of paragraph (b) of this

    section, or;

    (B) Minimum A-0 Class where there is a Type 8, 12 or 13 space on either

    side of the division; and

    The CFR specifies specific fire boundaries via tables that cross reference hot and cold side

    space designations. Space designations are determined based on overall fire risk.

    316

    Rules and Regulations Marine Composites

  • 8/10/2019 W_Regulations.pdf

    9/11

    American Bureau of Shipping

    The American Bureau of Shipping (ABS) is a nonprofit organization that develops rules for the

    classification of ship structures and equipment. ABS publishes about 90 different rules and

    guides, written in association with industry. Although ABS is primarily associated with large,

    steel ships, their involvement with small craft dates back to the 1920s, when a set of rules forwood sailing ship construction was published. The recent volume of work done for FRP

    yachts is summarized in Table 6-2. The publications and services offered by ABS are detailed

    below. [6-2]

    Rules for Building and Classing Reinforced Plastic Vessels 1978

    This publication gives hull structure, machinery and engineering system requirements for

    commercial displacement craft up to 200 feet in length. It contains comprehensive sections on

    materials and manufacture and is essentially for E-glass chopped strand mat and woven roving

    laminates with a means of approving other laminates given.

    These general Rules have served and continue to service industry and ABS very well - they are

    adopted as Australian Government Regulations and are used by the USCG. They are appliedcurrently by ABS to all commercial displacement craft in unrestricted ocean service.

    Table 6-2 Statistics on ABS Services for FRP Yachts During the Past Decade[Curry, American Bureau of Shipping]

    ABS ServiceSailing

    YachtsMotor

    Yachts

    Completed or contracted for class orhull certification as of 1989

    336 94

    Plan approval service only as of1989

    160 9

    Currently in class (as of 1989) 121 164

    Plan approval service from 1980 to1989

    390 35

    Guide for Building and Classing Offshore Racing Yachts, 1986This guide developed by ABS at the request of the Offshore Racing Council (ORC) 1978-1980

    out of their concern for ever lighter advanced composite boats and the lack of suitable

    standards. At that time, several boats and lives had been lost. ABS staff referred to the design

    and construction practice for offshore racing yachts reflected in designers' and builders' practice

    and to limited full-scale measured load data and refined the results by analysis of manyexisting proven boats and analysis of damaged boat structures.

    As the Guide was to provide for all possible hull materials, including advanced composites, it was

    essential that it be given in a direct engineering format of design loads and design stresses, based on

    ply, laminate and core material mechanical properties. Such a format permits the designer to readily

    see the influence of design loads, material mechanical properties and structural arrangement on the

    requirements, thereby giving as much freedom as possible to achieve optimum use of materials.

    317

    Chapter Six REFERENCE

  • 8/10/2019 W_Regulations.pdf

    10/11

    ABS is revising their approach for yachts, with special emphasis on vessels over 24 meters (78.7

    feet). The initiative combines revised structural and machinery criteria and requirements for structural

    fire protection and one compartment damage stability. ABS will no longer offer other services (such

    as plan approval only) for yachts over 24 meters and no services for yachts under 24 meters will be

    available.

    Guide for Building and Classing High Speed CraftSince 1980, ABS has had specific in-house guidance for the hull structure of planing and

    semi-planing craft in commercial and government service. The High-Speed Craft Guide was

    first published in 1990 and is under revision for publication in 1997.

    This Guide, for vessels up to 200 feet in length, covers glass fiber reinforced plastic, advanced

    composite, aluminum and steel hulls. Requirements are given in a direct engineering format

    expressed in terms of design pressures, design stresses, and material mechanical properties. Design

    planing slamming pressures for the bottom structure have been developed from the work of

    Heller and Jasper [6-3] Savitsky and Brown, [6-4] Allen and Jones [6-5], and Spencer [6-6].

    Those for the side structure are based on a combination of hydrostatic and speed induced

    hydrodynamic pressures.

    In establishing the bottom design pressures and dynamic components of side structure,

    distinction is made for example between passenger-carrying craft, general commercial craft,

    and mission type craft, such as patrol boats. Design pressures for decks, superstructures,

    houses and bulkheads are from ABS and industry practice.

    Design stresses, have been obtained from ABS in-house guidance and from applying the

    various design pressures to many existing, proven vessels processed over the years by ABS. In

    providing requirements for advanced composites, criteria are given for strength in both 0 and

    90 axes of structural panels.

    Anticipating the desirability of extending the length of boats using standard or advanced

    composites, the Guide contains hull-girder strength requirements for vessels in both the

    displacement and planing modes. The former comes from current ABS Rules. The latter from

    Heller and Jasper bending moments together with hull-girder bending stresses obtained by

    applying these moments to many existing, proven planing craft designs. As might be expected,

    design stresses for the planing mode bending moments are relatively low, reflecting a need for

    design that accounts for fatigue strength.

    Particularly for fiber reinforced plastic boats, criteria were established for hull-girder stiffness,

    by which, one of the potential limitations of fiber reinforced plastic, low tensile and

    compressive modulii, can be avoided by proper design.

    Although the Guide contains specific, detailed standards for planing craft hull structures, it is

    not confined to these form hulls and operational modes. Brief, general requirements for

    surface effect, air cushion and hydrofoil craft are also included. The updated Guide will cover

    monohull vessels to 450 feet and catamarans to 350 feet. A dedicated machinery and structural

    fire protection section is to be added. Panel testing of hull bottom and topsides will be

    required, as will be builder's process descriptions. A laminate stack program will be

    included.

    318

    Rules and Regulations Marine Composites

  • 8/10/2019 W_Regulations.pdf

    11/11

    Guide for High Speed and Displacement Motor Yachts

    As with high speed commercial and government service craft, ABS has utilized in-house

    guidance for many years for planing motor yachts. This has also been developed over the last

    few years into the Guide for High Speed and Displacement Motor Yachts.

    The standards for high speed motor yachts parallel those for high speed commercial and

    government service craft and the preceding description of the Guide for the high speed

    commercial, patrol, and utility craft is equally applicable with the qualification that the design

    pressures for motor yachts reflect the less rigorous demands of this service.

    Probably 80% to 90% of the motor yachts today are, by definition of this Guide, high speed.

    However to provide complete standards, the Guide also includes requirements for displacement

    motor yachts. Design loads and design stresses for these standards developed from ABS Rules

    for Reinforced Plastic Vessels, modified appropriately for advanced composite, aluminum and

    steel hulls and fine-tuned by review of a substantial number of existing proven, displacement

    hull motor yacht designs. In addition to hull structural standards, this Guide includes

    requirements for propulsion systems and essential engineering systems.

    ABS has reviewed approximately 50 motor pleasure yachts since 1990. The average waterline

    length is 100 feet with a top speed of 24 knots. Figure 6-1 graphically depicts the ABS

    classification process.

    319

    Chapter Six REFERENCE

    Figure 6-1 Flow Chart for ABS Classification Process [Curry, American Bureau ofShipping]