Workplace GeneralBrochure USA FGW5600 SEC

Embed Size (px)

Citation preview

  • 8/13/2019 Workplace GeneralBrochure USA FGW5600 SEC

    1/6

    FORUM Glaucoma Workplace from ZEISS

    See the solution from every angle

  • 8/13/2019 Workplace GeneralBrochure USA FGW5600 SEC

    2/6

    FORUM Glaucoma WorkplaceStructure and function analysis at your ngertips

    Streamline your workow

    HFA analyses in the lane

    The ZEISS FORUM Glaucoma Workplace easily allows

    you to review and generate HFA reports directly in the

    FORUM Viewer. For follow-up visits, a GPA summary can

    be automatically produced following 3 or more exams.And, with just a single click of the mouse, baseline exams

    can be changed and outliers removed. Additional to the

    GPA screen, an overview of visual eld exams is available.

    Review and analysis at your ngertips

    FORUM gives you on-demand access to visual fields,

    OCT scans, and structure and function results wherever

    you are, whenever you want including your office,

    at a workstation, or in the examination lanes.

    Better patient ow throughout the ofce

    The FORUM Glaucoma Workplace streamlines your

    assessments for more efcient patient ow with no

    compromise to the quality of care. Now, instead of

    searching through stacks of paper reports, you can

    fully focus on the patient examination.

    Simplied patient education during the consultation

    GPA and Combined Reports from FORUM save you time

    and simplify patient consultations, enhancing the patient

    education experience and potentially improving compliance.

    Review relevant HFA and CIRRUS

    data in one combined report

    Doctors want the ability to analyze Humphrey

    Field Analyzer (HFA) data in their office. Now,

    with the FORUM Glaucoma Workplace from

    ZEISS, they have it. The FORUM Glaucoma

    Workplace uses the same STATPAC engine as

    the HFA. Guided Progression Analysis (GPA)

    analyses are automatically performed and instantlyavailable once three or more exams have been

    stored. For the rst time, you can change the

    baselines for GPA analyses and generate HFA

    reports from a Mac or PC right in your practice.

    Doctors also want greater integration of HFA

    and CIRRUS HD-OCT analysis data in a single

    report. Here, too, FORUM delivers.

    2

  • 8/13/2019 Workplace GeneralBrochure USA FGW5600 SEC

    3/6

    Master your data

    FORUM Viewer integration

    The FORUM Glaucoma Workplace is a clinical application

    that is directly integrated into the FORUM infrastructure.

    Advanced user experi ence

    As an integral part of the modern FORUM platform, the

    FORUM Glaucoma Workplace lets you take full advantage

    of the latest FORUM enhancements and features, giving

    you an advanced user experience across all solutions.

    Convenient installation

    ZEISS service technicians will assist you with all aspects

    of the software installation.

    Consistent data management

    FORUM ensures end-to-end data consistency across

    the board between the HFA, CIRRUS, FORUM and the

    FORUM Glaucoma Workplace.

    Focus your assessments

    Adjust GPA parameters as needed

    If necessary, you can adjust GPA parameters by

    conveniently changing the baseline, resetting the baseline

    after surgery, or excluding any outliers.

    Combined structure and function reports

    The HFA-CIRRUS Combined Report from FORUM summarizes

    patient structure and function analyses in a single display.

    FORUM delivers this OD-OS integration to your lanes to help

    you assess patient status at a glance.

    3

  • 8/13/2019 Workplace GeneralBrochure USA FGW5600 SEC

    4/6

    GPA Summary Report for HFA

    The diagnosis and management of glaucoma relies on the critical assessment of visual field test status and progression.

    The GPA Summary Report can help estimate the current stage of visual field loss and rate of progression, to support the

    assessment of a patients risk of future vision loss.

    VFI PlotRegression analysis of VFI valuesand 3 to 5 year projection.

    VFI BarA graphical estimate of the

    patients remaining useful visionat the current VFI value alongwith a 3 to 5 year projection ofthe VFI regression line if the currenttrend continues.

    42

    3 Baseline ExamsDocument initial visualeld status.

    VFI Rate ofProgression Analysis

    Trend analysis of the patientsoverall visual eld history.

    1 Selected Follow-up Visual Field SummaryConclusive report of most recentvisual eld including VFI, MD, PSD,the Progression Analysis ProbabilityPlot and the GPA alert.

    GPA AlertA message that indicates whetherstatistically signicant deteriorationwas noted in consecutive tests.

    6

    5

    1

    2

    3

    5

    6

    4

    Right Eye Left Eye

  • 8/13/2019 Workplace GeneralBrochure USA FGW5600 SEC

    5/6

    HFA-CIRRUS Combined Report

    1

    23

    54

    6

    9 11

    7

    10

    8

    5

    4

    3

    2

    1

    HFA Visual Field Section

    HFA Graytone Plot, OD

    HFA Test Strategy, OS

    HFA Total Deviation and PatternDeviation Plots, OS

    HFA Global Indices, OS

    HFA Reliability Indices, OS

    8

    7

    6

    11

    10

    9

    CIRRUS HD-OCT Section

    RNFL Thickness Graph, OU

    RNFL Quadrants and Clock Hours

    Neuro-retinal Rim Thickness Graphwith normative data comparison, OU

    Table of RNFL and optic d iscparameters with normative

    data comparison, OURNFL Thickness Deviation Map, OS

    RNFL Thickness Map, OS

    The HFA-Cirrus Combined Report from FORUM summarizes patient structure and function analyses in a single display.

    FORUM delivers this OD-OS integration to your lanes to help you assess patient status at a glance.

  • 8/13/2019 Workplace GeneralBrochure USA FGW5600 SEC

    6/6

    Outstanding features

    Enables HFA analysis within the FORUM Viewer

    Combines structure and function information fromthe CIRRUS HD-OCT and HFA in one report with FORUM

    Automatically generates reports

    (eg. SFA, Overview, GPA, visual eld repor ts)

    FORUM Glaucoma Workplace

    Enables interactive adjustment of GPA parameters

    (eg. change baseline) Shows evolution of the GPA triangle plots animated

    over time (cine-mode)

    Improves patient flow and education

    F G W

    . 5 6 0 0

    P r i n t e d i n U S A

    . 5 M

    C Z - 1 0 / 2 0 1 3

    T h e c o n t e n t s o f t h e b r o c h u r e m a y

    d i f f e r

    f r o m t h e c u r r e n t s t a t u s o f a p p r o v a l o f t h e p r o d u c t

    i n y o u r c o u n t r y . P l e a s e c o n t a c t o u r r e g i o n a l r e p r e s e n t a t

    i v e

    f o r m o r e

    i n f o r m a t

    i o n .

    S u b j e c t t o c h a n g e

    i n d e s i g n a n

    d s c o p e o f

    d e l i v e r y a n

    d a s a r e s u

    l t o f o n g o

    i n g t e c h n i c a

    l d e v e l o p m e n t . F O R U M

    , C I R R U S , H u m p h r e y , H F A

    , G u i

    d e d P r o g r e s s

    i o n A n a

    l y s i s , G P A a n

    d V F I a r e e i t h e r t r a d e -

    m a r

    k s o r r e g i s t e r e d t r a d e m a r

    k s o f C a r

    l Z e i s s

    .

    Minimum requirements for FORUM Glaucoma Workplace

    Processor Intel Pentium 1.8 GHz (or faster)

    Free RAM At least 3 GB RAMIf the FORUM server and FORUM client application are run on the same computer,a minimum of 8 GB RAM is recommended.

    Free hard disc capacity Min. 4.0 GB free space on HDD

    Screen resolution 1280 x 800 pixels min.

    Operating system The FORUM Glaucoma Workplace server must be installed on the same computer as the FORUM serverapplication. The hardware requirements are the same as for the FORUM server and client application.

    Back ofce

    Fundus photography

    CIRRUS HD-OCT HumphreyField Analyzer

    (HFA)

    HumphreyField Analyzer

    (HFA)

    Exam lane 2 Exam lane 1

    Practice receptionarea FORUM Archive

    Electronic Medical Record

    FORUM Viewer

    Carl Zeiss Meditec, Inc.5160 Hacienda DriveDublin, CA 94568USAwww.meditec.zeiss.com

    Carl Zeiss Meditec AGGoeschwitzer Str. 51-5207745 JenaGermanywww.meditec.zeiss.com/forum

    CIRRUS HD-OCTHumphrey Field Analyzer FORUM

    Carl Zeiss Meditec AGGoeschwitzer Str. 51-5207745 JenaGermanywww.meditec.zeiss.com

    0297 0297