Upload
dnice408
View
217
Download
0
Embed Size (px)
Citation preview
8/13/2019 Workplace GeneralBrochure USA FGW5600 SEC
1/6
FORUM Glaucoma Workplace from ZEISS
See the solution from every angle
8/13/2019 Workplace GeneralBrochure USA FGW5600 SEC
2/6
FORUM Glaucoma WorkplaceStructure and function analysis at your ngertips
Streamline your workow
HFA analyses in the lane
The ZEISS FORUM Glaucoma Workplace easily allows
you to review and generate HFA reports directly in the
FORUM Viewer. For follow-up visits, a GPA summary can
be automatically produced following 3 or more exams.And, with just a single click of the mouse, baseline exams
can be changed and outliers removed. Additional to the
GPA screen, an overview of visual eld exams is available.
Review and analysis at your ngertips
FORUM gives you on-demand access to visual fields,
OCT scans, and structure and function results wherever
you are, whenever you want including your office,
at a workstation, or in the examination lanes.
Better patient ow throughout the ofce
The FORUM Glaucoma Workplace streamlines your
assessments for more efcient patient ow with no
compromise to the quality of care. Now, instead of
searching through stacks of paper reports, you can
fully focus on the patient examination.
Simplied patient education during the consultation
GPA and Combined Reports from FORUM save you time
and simplify patient consultations, enhancing the patient
education experience and potentially improving compliance.
Review relevant HFA and CIRRUS
data in one combined report
Doctors want the ability to analyze Humphrey
Field Analyzer (HFA) data in their office. Now,
with the FORUM Glaucoma Workplace from
ZEISS, they have it. The FORUM Glaucoma
Workplace uses the same STATPAC engine as
the HFA. Guided Progression Analysis (GPA)
analyses are automatically performed and instantlyavailable once three or more exams have been
stored. For the rst time, you can change the
baselines for GPA analyses and generate HFA
reports from a Mac or PC right in your practice.
Doctors also want greater integration of HFA
and CIRRUS HD-OCT analysis data in a single
report. Here, too, FORUM delivers.
2
8/13/2019 Workplace GeneralBrochure USA FGW5600 SEC
3/6
Master your data
FORUM Viewer integration
The FORUM Glaucoma Workplace is a clinical application
that is directly integrated into the FORUM infrastructure.
Advanced user experi ence
As an integral part of the modern FORUM platform, the
FORUM Glaucoma Workplace lets you take full advantage
of the latest FORUM enhancements and features, giving
you an advanced user experience across all solutions.
Convenient installation
ZEISS service technicians will assist you with all aspects
of the software installation.
Consistent data management
FORUM ensures end-to-end data consistency across
the board between the HFA, CIRRUS, FORUM and the
FORUM Glaucoma Workplace.
Focus your assessments
Adjust GPA parameters as needed
If necessary, you can adjust GPA parameters by
conveniently changing the baseline, resetting the baseline
after surgery, or excluding any outliers.
Combined structure and function reports
The HFA-CIRRUS Combined Report from FORUM summarizes
patient structure and function analyses in a single display.
FORUM delivers this OD-OS integration to your lanes to help
you assess patient status at a glance.
3
8/13/2019 Workplace GeneralBrochure USA FGW5600 SEC
4/6
GPA Summary Report for HFA
The diagnosis and management of glaucoma relies on the critical assessment of visual field test status and progression.
The GPA Summary Report can help estimate the current stage of visual field loss and rate of progression, to support the
assessment of a patients risk of future vision loss.
VFI PlotRegression analysis of VFI valuesand 3 to 5 year projection.
VFI BarA graphical estimate of the
patients remaining useful visionat the current VFI value alongwith a 3 to 5 year projection ofthe VFI regression line if the currenttrend continues.
42
3 Baseline ExamsDocument initial visualeld status.
VFI Rate ofProgression Analysis
Trend analysis of the patientsoverall visual eld history.
1 Selected Follow-up Visual Field SummaryConclusive report of most recentvisual eld including VFI, MD, PSD,the Progression Analysis ProbabilityPlot and the GPA alert.
GPA AlertA message that indicates whetherstatistically signicant deteriorationwas noted in consecutive tests.
6
5
1
2
3
5
6
4
Right Eye Left Eye
8/13/2019 Workplace GeneralBrochure USA FGW5600 SEC
5/6
HFA-CIRRUS Combined Report
1
23
54
6
9 11
7
10
8
5
4
3
2
1
HFA Visual Field Section
HFA Graytone Plot, OD
HFA Test Strategy, OS
HFA Total Deviation and PatternDeviation Plots, OS
HFA Global Indices, OS
HFA Reliability Indices, OS
8
7
6
11
10
9
CIRRUS HD-OCT Section
RNFL Thickness Graph, OU
RNFL Quadrants and Clock Hours
Neuro-retinal Rim Thickness Graphwith normative data comparison, OU
Table of RNFL and optic d iscparameters with normative
data comparison, OURNFL Thickness Deviation Map, OS
RNFL Thickness Map, OS
The HFA-Cirrus Combined Report from FORUM summarizes patient structure and function analyses in a single display.
FORUM delivers this OD-OS integration to your lanes to help you assess patient status at a glance.
8/13/2019 Workplace GeneralBrochure USA FGW5600 SEC
6/6
Outstanding features
Enables HFA analysis within the FORUM Viewer
Combines structure and function information fromthe CIRRUS HD-OCT and HFA in one report with FORUM
Automatically generates reports
(eg. SFA, Overview, GPA, visual eld repor ts)
FORUM Glaucoma Workplace
Enables interactive adjustment of GPA parameters
(eg. change baseline) Shows evolution of the GPA triangle plots animated
over time (cine-mode)
Improves patient flow and education
F G W
. 5 6 0 0
P r i n t e d i n U S A
. 5 M
C Z - 1 0 / 2 0 1 3
T h e c o n t e n t s o f t h e b r o c h u r e m a y
d i f f e r
f r o m t h e c u r r e n t s t a t u s o f a p p r o v a l o f t h e p r o d u c t
i n y o u r c o u n t r y . P l e a s e c o n t a c t o u r r e g i o n a l r e p r e s e n t a t
i v e
f o r m o r e
i n f o r m a t
i o n .
S u b j e c t t o c h a n g e
i n d e s i g n a n
d s c o p e o f
d e l i v e r y a n
d a s a r e s u
l t o f o n g o
i n g t e c h n i c a
l d e v e l o p m e n t . F O R U M
, C I R R U S , H u m p h r e y , H F A
, G u i
d e d P r o g r e s s
i o n A n a
l y s i s , G P A a n
d V F I a r e e i t h e r t r a d e -
m a r
k s o r r e g i s t e r e d t r a d e m a r
k s o f C a r
l Z e i s s
.
Minimum requirements for FORUM Glaucoma Workplace
Processor Intel Pentium 1.8 GHz (or faster)
Free RAM At least 3 GB RAMIf the FORUM server and FORUM client application are run on the same computer,a minimum of 8 GB RAM is recommended.
Free hard disc capacity Min. 4.0 GB free space on HDD
Screen resolution 1280 x 800 pixels min.
Operating system The FORUM Glaucoma Workplace server must be installed on the same computer as the FORUM serverapplication. The hardware requirements are the same as for the FORUM server and client application.
Back ofce
Fundus photography
CIRRUS HD-OCT HumphreyField Analyzer
(HFA)
HumphreyField Analyzer
(HFA)
Exam lane 2 Exam lane 1
Practice receptionarea FORUM Archive
Electronic Medical Record
FORUM Viewer
Carl Zeiss Meditec, Inc.5160 Hacienda DriveDublin, CA 94568USAwww.meditec.zeiss.com
Carl Zeiss Meditec AGGoeschwitzer Str. 51-5207745 JenaGermanywww.meditec.zeiss.com/forum
CIRRUS HD-OCTHumphrey Field Analyzer FORUM
Carl Zeiss Meditec AGGoeschwitzer Str. 51-5207745 JenaGermanywww.meditec.zeiss.com
0297 0297