6
• 4, 8, 16 or 32 channels • Options for electrical and optical stimulation • Lightweight headstages • Excellent signal-to-noise ratio • Parallel recordings possible • Option to access analog data Wireless-Systems The all-in-one solution for wireless recording and stimulating in vivo

Wireless-Systems - qichi-instruments.com interface USB 3.0 ... Battery level and signal quality are ... Data files are exported into HDF5 (e.g. Matlab, Python), .nex

Embed Size (px)

Citation preview

• 4,8,16or32channels

• Optionsforelectricalandopticalstimulation

• Lightweightheadstages

• Excellentsignal-to-noiseratio

• Parallelrecordingspossible

• Optiontoaccessanalogdata

Wireless-SystemsTheall-in-onesolutionforwirelessrecordingandstimulatingin vivo

Wireless-Systems: Technical specifications Numberofchannels 4,8,16or32

Dimensions(WxDxH)

(Widthw/oantennas;heightw/obattery)

Weight(Headstagewithoutbattery)

Battery Lithium-Polymer,rechargeable

Batterytypesandapprox.weights

(Standardbatteries,othercapacities

availableonrequest)

Batterylife(untilrecharge) e.g.32channelswith100mAhbattery:approx.1hour

Resolution 16bit

Inputvoltagerange ±12.4mV

Samplingrate(kHzperchannel)

Bandwidth 1Hzto5kHz(0.1Hzonrequest)

Distanceforwirelesslink 5mguaranteed(undernormallabconditions)

Controlinterface USB3.0

Software:

Operatingsystem Windows7or8(EnglishandGermanversionssupported)

MultiChannelSuite Version1.5.0andhigher

MultiChannelSystemsMCSGmbH

Aspenhaustraße2172770ReutlingenGermany

Fon+49-7121-9092525Fax +49-7121-9092511

[email protected]

Samplingrate(kHz/ch) Numberofselectedchannels

2 4 8 16 32

Typeofheadstage

W2100-HS4 40 32 - - -

W2100-HS8 40 40 25 - -

W2100-HS16 40 40 25 25 -

W2100-HS32 40 40 25 25 20W2100-HS4-opto 10 10

Typeofheadstage Weightofheadstage

W2100-HS4 1.9g

W2100-HS8 2.8g(OM),3.1g(SR)

W2100-HS16 2.9g

W2100-HS32 3.7g

W2100-HS4-opto 1.9g

W2100-HS8-ES2 3.7g

W2100-HS14-ES2 3.7g

W2100-HS-EEG/EMG/Temp 3.0g

Capacity Weightofbattery(cableorbatteryboard)

30mAh 1.5g;1.5g

100mAh(standard) 3.7g;3.8g

200mAh 5.1g;6.7g

300mAh 8.1g;8.7g

Typeofheadstage Dimension

W2100-HS4 13x13x5.5mm

W2100-HS8 15.5x15.5x5mm

W2100-HS16 15.5x15.5x5mm

W2100-HS32 15.5x15.5x6.7mm

W2100-HS4-opto 13x13x5.5mm

W2100-HS8-ES2 15.5x15.5x5mm

W2100-HS14-ES2 15.5x15.5x5mm

W2100-HS-EEG/EMG/Temp 15.5x15.5x5mmDistributed by:

©February2016MultiChannelSystemsMCSGmbH

Productinformationissubjecttochangewithoutnotice.Productsthatarereferredtointhisdocumentmaybeeithertrademarksand/orregisteredtrademarksoftherespectiveowners.Thepublisherandtheauthormakenoclaimtothesetrademarks.

Versatile software: Multi Channel SuiteTheWireless-Systemcomeswiththepowerfulandeasy-to-usesoftwarepackageMulti

ChannelSuite. Itconsistsofthreeprogramsandupdatesareavailableforfreefrom

theMCSwebsite.

Multi Channel Experimenterfordataacquisitionandonlineanalysis.Withaneasy-

to-use drag’n’drop interface, you simply create your virtual experiment adding e.g.

datasource,filters,spikedetection,andrecorder.Batterylevelandsignalqualityare

indicatedhereandyourdataisdisplayedinreal-time.

Multi Channel Analyzerforofflineanalysis.Youjustimporttherecordeddataand

defineyourin-depthanalysiswithadditionalinstruments.TheMultiChannelAnalyzer

alsosupportssynchronizedvideoinputforbehavioralresearchwithfreelymoving

animals.Both,thevideodataandelectrophysiologicalrecordingsaredisplayedin

parallelandyoucaneasilyskipthroughthedatafromoneeventtothenext.

Multi Channel DataManager fordataexportforfurtheranalysiswiththird-

partyprograms.DatafilesareexportedintoHDF5(e.g.Matlab,Python),.nex

(Neuroexplorer)or.ced(Spike2).Independentofthefileformat,theexportisdone

quicklyandadatacompresssionisincluded.

Wireless recording systemThe Wireless-System from Multi Channel

Systems is the all-in-one solution for

amplifying,recording,andanalyzingin vivo

datafrom4,8,16or32channels.

Theamplifierbandwidth is1Hzto5kHz,

sampled at up to 40 kHz per channel

simultaneously.Witharesolutionof16bit,

theaccuracyofyourdataisguaranteed.

The systems include everything you need:

Small-sizedheadstagewith integratedA/D

converterandLEDlightsforvideotracking,

digitized transmission, powerful receiver,

interface board, and data acquisition

softwarepackage.

With its excellent signal-to-noise ratio,

it is the ideal solution for recording

spikes, LFP, EEG, ECG, EMG, and ECoG.

Additional inputs to the interface board

allowthesynchronizationofyourdatawith

externaldevices.

Modular setup of headstagesThewirelessheadstagesarebuiltaccord-

ingtoyourneeds.Thelevel-basedcon-

structionmakescustom-builtheadstages

possible.Yourheadstagecanconsistof

levels foramplificationandA/Dconver-

sion, electrical or optical stimulation,

motion sensors and many more which

arecurrentlyunderdevelopment.

Key advantage: Digital data transmissionThe Wireless-System converts the

recordedsignalsintodigitaldataalready

ontheheadstage.

This guarantees an excellent signal-

to-noise ratio which is independent

fromthedistancebetweensenderand

receiver.

Incombinationwithalongtransmission

range, the digital data transmission

permits flexible long-term experiments

inlargeenvironments.

Parallel experimentsThe Wireless-System offers the possibility

to record from up to eight animals

simultaneously with one setup (at a

reduced sampling rate). Up to four receivers

can be run in parallel in the same room,

with a total number of 16 headstages.

A/D,amplifier

Electricalstimulation

Motiontracking

Opticalstimulation

A/D, amplifier

Motion tracking

Electrical stimulation

Optical stimulation

Interface BoardConnectiontocomputer

SoftwareDatavisualizationandanalysis

ReceiverMicroprocessor

HeadstageA/Dconverterandtransmitter

AnyPCorlaptopcanbeused

DigitalWirelessTransmission

Energy-efficiency and flexibilityAlldevicesoftheWireless-Systemsaredesignedtobe

energy-efficient.Thestandardbatteryoftheheadstage

permitscontinuousrecordingofallchannelsforapprox.

2 hours (details on back side). Recharging is then

realizedviaaUSBcharger.

Forrecordinginanimals insensitivetoweight,wealso

offer larger batteries, which provide longer recording

times.PleasecontactMultiChannelSystems formore

informationonbatteryoptions.

Forpower-saving, theheadstage switches to stand-by

modeassoonasthedataacquisitionisstopped.When

recording continues, the headstage switches on

automatically. Another possibility is to turn off the

headstagecompletelyviathedataacquisitionsoftware.

Forswitchingonwithoutanyinterference,justusethe

includedinfraredflashlightwhichdoesnotdisturbthe

animal.

Singlechannelscanalwaysbeswitchedonandofffor

recordingviasoftware.Thisallowsyoutoadjustenergy

consumptionandsamplingratewheneveryoulike.

Various possibilities for battery placement and electrode connectionsFor maximum flexibility, we offer headstages with

connections to any type of probes. Just let us know

which probe you want to use and we will provide the

correspondingconnector.

Moreover, depending on your experiment, you can also

decide where to position the battery of the headstage.

Eitherfixitontheheadstageitselforuseaspecialbackpack

for the cable-connected battery. Independent of your

decision,besurethatthebatteryissmallandlightweightin

ordertonotinfluenceyourexperiment.

Active Recording

Stand-ByLow battery consumption

Switched OffMarginal battery

consumption

Automaticallywhenstoppingdataacquisition

Switchingviacontrolsoftware

Switchingviainfraredflashlight,includedin

thesystem

Automaticallywhenstartingdataacquisition

Electrical and optical stimulationMCS uniquely provides headstages for optical and electrical

stimulation.

You do not need to give up valuable recording

informationwhilestimulating;theheadstagesallowyou

torecordandstimulatesimultaneously!

Theheadstageforopticalstimulationoffersaninterface

to2LEDs.So inaddition to4 recordingchannels,you

can program2 stimulation patterns for the connected

LEDs.

Theheadstageforelectricalstimulationhas2dedicated

stimulationchannelswithcurrentoutputinadditionto

either8or14recordingchannels.

Opticalaswellaselectricalstimulationpatternscanbe

designedfreelyviatheincludedsoftwareMultiChannel

Experimenter.

Analog output to any data acquistionGenerally,theWireless-Systemsarecom-

pleteworkstationswithdataacquisition

and software from Multi Channel Sys-

tems.

However,youhavetheoptiontoaddan

analogoutputofallchannels.

Youcanthenconnectyourexistingdata

acquisitionandanalyzethedatainyour

software.

Thisgivesyoutheflexibilitytointegrate

theMCS-Wireless-System in your exist-

ingset-upandusetheperipheralequip-

mentyouarefamiliarwith-whileadding

valuable,undisturbedin vivo data.

Versatile software: Multi Channel SuiteTheWireless-Systemcomeswiththepowerfulandeasy-to-usesoftwarepackageMulti

ChannelSuite. Itconsistsofthreeprogramsandupdatesareavailableforfreefrom

theMCSwebsite.

Multi Channel Experimenterfordataacquisitionandonlineanalysis.Withaneasy-

to-use drag’n’drop interface, you simply create your virtual experiment adding e.g.

datasource,filters,spikedetection,andrecorder.Batterylevelandsignalqualityare

indicatedhereandyourdataisdisplayedinreal-time.

Multi Channel Analyzerforofflineanalysis.Youjustimporttherecordeddataand

defineyourin-depthanalysiswithadditionalinstruments.TheMultiChannelAnalyzer

alsosupportssynchronizedvideoinputforbehavioralresearchwithfreelymoving

animals.Both,thevideodataandelectrophysiologicalrecordingsaredisplayedin

parallelandyoucaneasilyskipthroughthedatafromoneeventtothenext.

Multi Channel DataManager fordataexportforfurtheranalysiswiththird-

partyprograms.DatafilesareexportedintoHDF5(e.g.Matlab,Python),.nex

(Neuroexplorer)or.ced(Spike2).Independentofthefileformat,theexportisdone

quicklyandadatacompresssionisincluded.

Wireless recording systemThe Wireless-System from Multi Channel

Systems is the all-in-one solution for

amplifying,recording,andanalyzingin vivo

datafrom4,8,16or32channels.

Theamplifierbandwidth is1Hzto5kHz,

sampled at up to 40 kHz per channel

simultaneously.Witharesolutionof16bit,

theaccuracyofyourdataisguaranteed.

The systems include everything you need:

Small-sizedheadstagewith integratedA/D

converterandLEDlightsforvideotracking,

digitized transmission, powerful receiver,

interface board, and data acquisition

softwarepackage.

With its excellent signal-to-noise ratio,

it is the ideal solution for recording

spikes, LFP, EEG, ECG, EMG, and ECoG.

Additional inputs to the interface board

allowthesynchronizationofyourdatawith

externaldevices.

Modular setup of headstagesThewirelessheadstagesarebuiltaccord-

ingtoyourneeds.Thelevel-basedcon-

structionmakescustom-builtheadstages

possible.Yourheadstagecanconsistof

levels foramplificationandA/Dconver-

sion, electrical or optical stimulation,

motion sensors and many more which

arecurrentlyunderdevelopment.

Key advantage: Digital data transmissionThe Wireless-System converts the

recordedsignalsintodigitaldataalready

ontheheadstage.

This guarantees an excellent signal-

to-noise ratio which is independent

fromthedistancebetweensenderand

receiver.

Incombinationwithalongtransmission

range, the digital data transmission

permits flexible long-term experiments

inlargeenvironments.

Parallel experimentsThe Wireless-System offers the possibility

to record from up to eight animals

simultaneously with one setup (at a

reduced sampling rate). Up to four receivers

can be run in parallel in the same room,

with a total number of 16 headstages.

A/D,amplifier

Electricalstimulation

Motiontracking

Opticalstimulation

A/D, amplifier

Motion tracking

Electrical stimulation

Optical stimulation

Interface BoardConnectiontocomputer

SoftwareDatavisualizationandanalysis

ReceiverMicroprocessor

HeadstageA/Dconverterandtransmitter

AnyPCorlaptopcanbeused

DigitalWirelessTransmission

Energy-efficiency and flexibilityAlldevicesoftheWireless-Systemsaredesignedtobe

energy-efficient.Thestandardbatteryoftheheadstage

permitscontinuousrecordingofallchannelsforapprox.

2 hours (details on back side). Recharging is then

realizedviaaUSBcharger.

Forrecordinginanimals insensitivetoweight,wealso

offer larger batteries, which provide longer recording

times.PleasecontactMultiChannelSystems formore

informationonbatteryoptions.

Forpower-saving, theheadstage switches to stand-by

modeassoonasthedataacquisitionisstopped.When

recording continues, the headstage switches on

automatically. Another possibility is to turn off the

headstagecompletelyviathedataacquisitionsoftware.

Forswitchingonwithoutanyinterference,justusethe

includedinfraredflashlightwhichdoesnotdisturbthe

animal.

Singlechannelscanalwaysbeswitchedonandofffor

recordingviasoftware.Thisallowsyoutoadjustenergy

consumptionandsamplingratewheneveryoulike.

Various possibilities for battery placement and electrode connectionsFor maximum flexibility, we offer headstages with

connections to any type of probes. Just let us know

which probe you want to use and we will provide the

correspondingconnector.

Moreover, depending on your experiment, you can also

decide where to position the battery of the headstage.

Eitherfixitontheheadstageitselforuseaspecialbackpack

for the cable-connected battery. Independent of your

decision,besurethatthebatteryissmallandlightweightin

ordertonotinfluenceyourexperiment.

Active Recording

Stand-ByLow battery consumption

Switched OffMarginal battery

consumption

Automaticallywhenstoppingdataacquisition

Switchingviacontrolsoftware

Switchingviainfraredflashlight,includedin

thesystem

Automaticallywhenstartingdataacquisition

Electrical and optical stimulationMCS uniquely provides headstages for optical and electrical

stimulation.

You do not need to give up valuable recording

informationwhilestimulating;theheadstagesallowyou

torecordandstimulatesimultaneously!

Theheadstageforopticalstimulationoffersaninterface

to2LEDs.So inaddition to4 recordingchannels,you

can program2 stimulation patterns for the connected

LEDs.

Theheadstageforelectricalstimulationhas2dedicated

stimulationchannelswithcurrentoutputinadditionto

either8or14recordingchannels.

Opticalaswellaselectricalstimulationpatternscanbe

designedfreelyviatheincludedsoftwareMultiChannel

Experimenter.

Analog output to any data acquistionGenerally,theWireless-Systemsarecom-

pleteworkstationswithdataacquisition

and software from Multi Channel Sys-

tems.

However,youhavetheoptiontoaddan

analogoutputofallchannels.

Youcanthenconnectyourexistingdata

acquisitionandanalyzethedatainyour

software.

Thisgivesyoutheflexibilitytointegrate

theMCS-Wireless-System in your exist-

ingset-upandusetheperipheralequip-

mentyouarefamiliarwith-whileadding

valuable,undisturbedin vivo data.

Versatile software: Multi Channel SuiteTheWireless-Systemcomeswiththepowerfulandeasy-to-usesoftwarepackageMulti

ChannelSuite. Itconsistsofthreeprogramsandupdatesareavailableforfreefrom

theMCSwebsite.

Multi Channel Experimenterfordataacquisitionandonlineanalysis.Withaneasy-

to-use drag’n’drop interface, you simply create your virtual experiment adding e.g.

datasource,filters,spikedetection,andrecorder.Batterylevelandsignalqualityare

indicatedhereandyourdataisdisplayedinreal-time.

Multi Channel Analyzerforofflineanalysis.Youjustimporttherecordeddataand

defineyourin-depthanalysiswithadditionalinstruments.TheMultiChannelAnalyzer

alsosupportssynchronizedvideoinputforbehavioralresearchwithfreelymoving

animals.Both,thevideodataandelectrophysiologicalrecordingsaredisplayedin

parallelandyoucaneasilyskipthroughthedatafromoneeventtothenext.

Multi Channel DataManager fordataexportforfurtheranalysiswiththird-

partyprograms.DatafilesareexportedintoHDF5(e.g.Matlab,Python),.nex

(Neuroexplorer)or.ced(Spike2).Independentofthefileformat,theexportisdone

quicklyandadatacompresssionisincluded.

Wireless recording systemThe Wireless-System from Multi Channel

Systems is the all-in-one solution for

amplifying,recording,andanalyzingin vivo

datafrom4,8,16or32channels.

Theamplifierbandwidth is1Hzto5kHz,

sampled at up to 40 kHz per channel

simultaneously.Witharesolutionof16bit,

theaccuracyofyourdataisguaranteed.

The systems include everything you need:

Small-sizedheadstagewith integratedA/D

converterandLEDlightsforvideotracking,

digitized transmission, powerful receiver,

interface board, and data acquisition

softwarepackage.

With its excellent signal-to-noise ratio,

it is the ideal solution for recording

spikes, LFP, EEG, ECG, EMG, and ECoG.

Additional inputs to the interface board

allowthesynchronizationofyourdatawith

externaldevices.

Modular setup of headstagesThewirelessheadstagesarebuiltaccord-

ingtoyourneeds.Thelevel-basedcon-

structionmakescustom-builtheadstages

possible.Yourheadstagecanconsistof

levels foramplificationandA/Dconver-

sion, electrical or optical stimulation,

motion sensors and many more which

arecurrentlyunderdevelopment.

Key advantage: Digital data transmissionThe Wireless-System converts the

recordedsignalsintodigitaldataalready

ontheheadstage.

This guarantees an excellent signal-

to-noise ratio which is independent

fromthedistancebetweensenderand

receiver.

Incombinationwithalongtransmission

range, the digital data transmission

permits flexible long-term experiments

inlargeenvironments.

Parallel experimentsThe Wireless-System offers the possibility

to record from up to eight animals

simultaneously with one setup (at a

reduced sampling rate). Up to four receivers

can be run in parallel in the same room,

with a total number of 16 headstages.

A/D,amplifier

Electricalstimulation

Motiontracking

Opticalstimulation

A/D, amplifier

Motion tracking

Electrical stimulation

Optical stimulation

Interface BoardConnectiontocomputer

SoftwareDatavisualizationandanalysis

ReceiverMicroprocessor

HeadstageA/Dconverterandtransmitter

AnyPCorlaptopcanbeused

DigitalWirelessTransmission

Energy-efficiency and flexibilityAlldevicesoftheWireless-Systemsaredesignedtobe

energy-efficient.Thestandardbatteryoftheheadstage

permitscontinuousrecordingofallchannelsforapprox.

2 hours (details on back side). Recharging is then

realizedviaaUSBcharger.

Forrecordinginanimals insensitivetoweight,wealso

offer larger batteries, which provide longer recording

times.PleasecontactMultiChannelSystems formore

informationonbatteryoptions.

Forpower-saving, theheadstage switches to stand-by

modeassoonasthedataacquisitionisstopped.When

recording continues, the headstage switches on

automatically. Another possibility is to turn off the

headstagecompletelyviathedataacquisitionsoftware.

Forswitchingonwithoutanyinterference,justusethe

includedinfraredflashlightwhichdoesnotdisturbthe

animal.

Singlechannelscanalwaysbeswitchedonandofffor

recordingviasoftware.Thisallowsyoutoadjustenergy

consumptionandsamplingratewheneveryoulike.

Various possibilities for battery placement and electrode connectionsFor maximum flexibility, we offer headstages with

connections to any type of probes. Just let us know

which probe you want to use and we will provide the

correspondingconnector.

Moreover, depending on your experiment, you can also

decide where to position the battery of the headstage.

Eitherfixitontheheadstageitselforuseaspecialbackpack

for the cable-connected battery. Independent of your

decision,besurethatthebatteryissmallandlightweightin

ordertonotinfluenceyourexperiment.

Active Recording

Stand-ByLow battery consumption

Switched OffMarginal battery

consumption

Automaticallywhenstoppingdataacquisition

Switchingviacontrolsoftware

Switchingviainfraredflashlight,includedin

thesystem

Automaticallywhenstartingdataacquisition

Electrical and optical stimulationMCS uniquely provides headstages for optical and electrical

stimulation.

You do not need to give up valuable recording

informationwhilestimulating;theheadstagesallowyou

torecordandstimulatesimultaneously!

Theheadstageforopticalstimulationoffersaninterface

to2LEDs.So inaddition to4 recordingchannels,you

can program2 stimulation patterns for the connected

LEDs.

Theheadstageforelectricalstimulationhas2dedicated

stimulationchannelswithcurrentoutputinadditionto

either8or14recordingchannels.

Opticalaswellaselectricalstimulationpatternscanbe

designedfreelyviatheincludedsoftwareMultiChannel

Experimenter.

Analog output to any data acquistionGenerally,theWireless-Systemsarecom-

pleteworkstationswithdataacquisition

and software from Multi Channel Sys-

tems.

However,youhavetheoptiontoaddan

analogoutputofallchannels.

Youcanthenconnectyourexistingdata

acquisitionandanalyzethedatainyour

software.

Thisgivesyoutheflexibilitytointegrate

theMCS-Wireless-System in your exist-

ingset-upandusetheperipheralequip-

mentyouarefamiliarwith-whileadding

valuable,undisturbedin vivo data.

• 4,8,16or32channels

• Optionsforelectricalandopticalstimulation

• Lightweightheadstages

• Excellentsignal-to-noiseratio

• Parallelrecordingspossible

• Optiontoaccessanalogdata

Wireless-SystemsTheall-in-onesolutionforwirelessrecordingandstimulatingin vivo

Wireless-Systems: Technical specifications Numberofchannels 4,8,16or32

Dimensions(WxDxH)

(Widthw/oantennas;heightw/obattery)

Weight(Headstagewithoutbattery)

Battery Lithium-Polymer,rechargeable

Batterytypesandapprox.weights

(Standardbatteries,othercapacities

availableonrequest)

Batterylife(untilrecharge) e.g.32channelswith100mAhbattery:approx.1hour

Resolution 16bit

Inputvoltagerange ±12.4mV

Samplingrate(kHzperchannel)

Bandwidth 1Hzto5kHz(0.1Hzonrequest)

Distanceforwirelesslink 5mguaranteed(undernormallabconditions)

Controlinterface USB3.0

Software:

Operatingsystem Windows7or8(EnglishandGermanversionssupported)

MultiChannelSuite Version1.5.0andhigher

MultiChannelSystemsMCSGmbH

Aspenhaustraße2172770ReutlingenGermany

Fon+49-7121-9092525Fax +49-7121-9092511

[email protected]

Samplingrate(kHz/ch) Numberofselectedchannels

2 4 8 16 32

Typeofheadstage

W2100-HS4 40 32 - - -

W2100-HS8 40 40 25 - -

W2100-HS16 40 40 25 25 -

W2100-HS32 40 40 25 25 20W2100-HS4-opto 10 10

Typeofheadstage Weightofheadstage

W2100-HS4 1.9g

W2100-HS8 2.8g(OM),3.1g(SR)

W2100-HS16 2.9g

W2100-HS32 3.7g

W2100-HS4-opto 1.9g

W2100-HS8-ES2 3.7g

W2100-HS14-ES2 3.7g

W2100-HS-EEG/EMG/Temp 3.0g

Capacity Weightofbattery(cableorbatteryboard)

30mAh 1.5g;1.5g

100mAh(standard) 3.7g;3.8g

200mAh 5.1g;6.7g

300mAh 8.1g;8.7g

Typeofheadstage Dimension

W2100-HS4 13x13x5.5mm

W2100-HS8 15.5x15.5x5mm

W2100-HS16 15.5x15.5x5mm

W2100-HS32 15.5x15.5x6.7mm

W2100-HS4-opto 13x13x5.5mm

W2100-HS8-ES2 15.5x15.5x5mm

W2100-HS14-ES2 15.5x15.5x5mm

W2100-HS-EEG/EMG/Temp 15.5x15.5x5mmDistributed by:

©February2016MultiChannelSystemsMCSGmbH

Productinformationissubjecttochangewithoutnotice.Productsthatarereferredtointhisdocumentmaybeeithertrademarksand/orregisteredtrademarksoftherespectiveowners.Thepublisherandtheauthormakenoclaimtothesetrademarks.

• 4,8,16or32channels

• Optionsforelectricalandopticalstimulation

• Lightweightheadstages

• Excellentsignal-to-noiseratio

• Parallelrecordingspossible

• Optiontoaccessanalogdata

Wireless-SystemsTheall-in-onesolutionforwirelessrecordingandstimulatingin vivo

Wireless-Systems: Technical specifications Numberofchannels 4,8,16or32

Dimensions(WxDxH)

(Widthw/oantennas;heightw/obattery)

Weight(Headstagewithoutbattery)

Battery Lithium-Polymer,rechargeable

Batterytypesandapprox.weights

(Standardbatteries,othercapacities

availableonrequest)

Batterylife(untilrecharge) e.g.32channelswith100mAhbattery:approx.1hour

Resolution 16bit

Inputvoltagerange ±12.4mV

Samplingrate(kHzperchannel)

Bandwidth 1Hzto5kHz(0.1Hzonrequest)

Distanceforwirelesslink 5mguaranteed(undernormallabconditions)

Controlinterface USB3.0

Software:

Operatingsystem Windows7or8(EnglishandGermanversionssupported)

MultiChannelSuite Version1.5.0andhigher

MultiChannelSystemsMCSGmbH

Aspenhaustraße2172770ReutlingenGermany

Fon+49-7121-9092525Fax +49-7121-9092511

[email protected]

Samplingrate(kHz/ch) Numberofselectedchannels

2 4 8 16 32

Typeofheadstage

W2100-HS4 40 32 - - -

W2100-HS8 40 40 25 - -

W2100-HS16 40 40 25 25 -

W2100-HS32 40 40 25 25 20W2100-HS4-opto 10 10

Typeofheadstage Weightofheadstage

W2100-HS4 1.9g

W2100-HS8 2.8g(OM),3.1g(SR)

W2100-HS16 2.9g

W2100-HS32 3.7g

W2100-HS4-opto 1.9g

W2100-HS8-ES2 3.7g

W2100-HS14-ES2 3.7g

W2100-HS-EEG/EMG/Temp 3.0g

Capacity Weightofbattery(cableorbatteryboard)

30mAh 1.5g;1.5g

100mAh(standard) 3.7g;3.8g

200mAh 5.1g;6.7g

300mAh 8.1g;8.7g

Typeofheadstage Dimension

W2100-HS4 13x13x5.5mm

W2100-HS8 15.5x15.5x5mm

W2100-HS16 15.5x15.5x5mm

W2100-HS32 15.5x15.5x6.7mm

W2100-HS4-opto 13x13x5.5mm

W2100-HS8-ES2 15.5x15.5x5mm

W2100-HS14-ES2 15.5x15.5x5mm

W2100-HS-EEG/EMG/Temp 15.5x15.5x5mmDistributed by:

©February2016MultiChannelSystemsMCSGmbH

Productinformationissubjecttochangewithoutnotice.Productsthatarereferredtointhisdocumentmaybeeithertrademarksand/orregisteredtrademarksoftherespectiveowners.Thepublisherandtheauthormakenoclaimtothesetrademarks.