2
WINSIX ® MACHINED IMPIANTO KT MACHINED IMPIANTO CONICO MACHINED www.implantologiawinsix.com App Store Google play I dispositivi medici a marchio WINSIX ® sono marcati CE (Classe I) e CE0476 (Classe IIA e IIB) in conformità alla Direttiva Dispositivi Medici 93/42/CEE e s.m.i. WINSIX ® Sedi BIOSAF IN in ITALIA: 60131 ANCONA via Tiraboschi 36/G 20060 MILANO Trezzano Rosa, via Cagliari, 32/44 tel. +39 071 2071897 - fax +39 071 203261 info@biosafin.com - assistenzaclienti@biosafin.com www.biosafin.com Principale Bibliografia di Riferimento del Sistema WINSIX ® An In Vitro Evaluation of Heat Production during Oste- otomy preparation for Dental Implants with compressi- ve Osteotomes - A.Quaranta, S.Andreana, L.Spazzafumo, M.Piemontese - Implant Dentistry Vol.22 N°2 - 2013 Maxillary sinus augmentation procedures through equi- ne-derived biomaterial or calvaria autologous bone: im- munohistochemical evaluation of OPG/RANKL in humans S.Tetè, R.Vinci, V.L.Zizzari, S.Zara, V.La Scala, A.Cataldi, E.F.Gherlone, A.Piattelli - European Journal of Histochemistry Vol.57: e10 - 2013 Airpolishing: protocollo sperimentale di studio in vitro per la gestione dei pazienti implantari affetti da mucosite e perimplantite - P. P. Paganin - L’igienista moderno Marzo 2013 Crestal bone remodeling around platform switched, im- mediately loaded implants placed in sites of previous failures A.Quaranta, A.Cicconetti, L.Battaglia, M.Piemontese, G.Pompa I.Vozza - European Journal of Inflammation Vol.10 N°2 Accepted July 30 - 2012 Use of Piezosurgery During Maxillary Sinus Elevation: Clinical Results of 40 Consecutive Cases M. Cassetta, L. Ricci, G. Iezzi, S. Calasso, A. Piattelli, V. Perrotti The International Journal of Periodontics & Restorative Dentistry Vol. 32 N°6 - 2012 Macroscopic and microscopic evaluation of a new im- plant design supporting immediately loaded full arch rehabilitation. S.Tetè, V. Zizzari, A. De Carlo, B.Sinjari, E. Gherlone Annali di Stomatologia. Vol. 3, n. 2 - 2012. Injectable Magnesium - Enriched Hydroxyapatite Putty in Peri- Implant Defects: A Histomorphometric Analysis in Pigs R. Crespi, P. Capparè, A. Addis, E. F. Gherlone - The International Journal of Oral & Maxillofacial Implants Vol 27, N° 1 - 2012 TEETH JUST ON SIX: Riabilitazione Implantoprotesica nei casi di Edentulia completa: un approccio diagnostico - terapeutico integrato M. Manacorda, R. Vinci, M. Pasi, E. F. Gherlone Odontoiatria, Rivista Amici di Brugg n°.1, anno 30°- Maggio - 2011 Long-Term Evaluation of Maxillary Reconstruction by Iliac Crest Bone Graft: A Morphologic and Immunohisto- chemical Study S. Tetè, R. Vinci, S. Zara, V. Zizzari, A. De Carlo, G. Falco, D. Tripodi, A. Cataldi, C. Mortellaro, E. F. Gherlone The Journal of Craniofacial Surgery Vol. 22, N°5 - Sept. 2011 Immunohistochemical analysis of matrix metalloprotei- nase-9, vascular endothelial growth factor, bone sialo- protein and i-nitric oxide synthase in calvaria vs. iliac crest bone grafts. S Tetè, S Zara, VL Zizzari, A De Carlo, R Vinci, A Cataldi, E. Gherlone -Clinical Oral Implants Research. Vol. 23, n. 11 - 2011. Microcomputed and Histologic Evaluation of Calvarial Bone Grafts: A pilot Study in Humans R. Vinci, A. Rebaudi, P. Capparè, E. F. Gherlone - The International Journal of Periodontics & Restorative Dentistry Vol.31, N° 4 2011 Tecniche Chirurgiche Piezoelettriche R. Vinci, M. Pasi, S. Tetè, E. F. Gherlone Panorama Dental – Sept. 2011 Ostheosynthesis plates, screws, xenogenic graft and re- sorbable barriers for preimplant and peri-implant surgery G. M. Rauso, N. Nesi, L. Fragola, M. Santagata, V. Santillo, R. Rauso - Minerva Stomatologica - 2010, 59:00-00 Utilizzo del Mucotomo per il rialzo del seno mascellare con approccio crestale: Report preliminare Use of the circular soft-tissue punch in maxillary sinus lifts with a crestal approach: a preliminary report F. Vannini, M. Nardone - Italian Oral Surgery 2010; 9 (6):1-14 Lembo di bolla di Bichat associato al lembo di Reh- rmann nella correzione plastica di ampia fistola oro antrale in paziente trattata con bifosfonati: Case Report M. Del Brutto, G .Alfieri, G. Mariani, C. Vianale, R .Mazzanti, G. Sammartino - Sessione Poster- Roma 18-19-20 Febbraio 2010 Difetti di spessore crestali: Utilizzo della tecnica Split Crest B. Marcelli, A. Delli Carpini, E. Coccia, M .Procaccini Sessione Poster-Roma 18-19-20 Febbraio 2010 Influence of Novel Nano-Titanium Implant Surface on Human Osteoblast Behavior and Growth S. Tetè, F. Mastrangelo, R. Quaresima, R. Vinci, G.Sammartino, L. Stuppia, E. F. Gherlone - Implant Dentistry, Vol.19, N° 6 2010 Chiave dinamometrica digitale: applicazioni in Implanto- protesi L. Prosper, M. Cappello, C. A. Cortella, T. D’Alicandro, E. F. Gherlone - QI Quintessenza Internazionale, anno 26 n. 1 Gennaio/Marzo 2010 L’Impiego della teca cranica a scopo implantoprotesico E. F. Gherlone, R. Vinci, L. D’Aversa Oral & Implantology Anno II N°2/ 2009 Effect of Implant Angulation, Connection Length, and Im- pression Material on the Dimensional Accuracy of Implant Impressions: An In Vitro Comparative Study R. Sorrentino, E. F. Gherlone, G. Calesini, F. Zarone Clinical implant dentistry and related Research, 2009 A Randomized Prospective Multicenter Trial Evaluating the Platform-Switching Technique for Prevention of Postrestorative Crestal Bone Loss L. Prosper, S. Redaelli, M. Pasi, F. Zarone, G. Radaelli, E. F. Gherlone - JOMI The international Journal of Oral & Maxillofacial - Implants – vol. 24 n. 2, 2009 Isolation of osteogenic progenitors from human amnio- tic fluid using a single step culture protocol I. Antonucci, I. Iezzi, E. Morizio, F. Mastrangelo,A. Pantalone, M. Mattioli Belmonte, A. Gigante, V. Salini, G. Calabrese, S. Tetè, G. Palka, L. Stuppia - SILENCE a Journal of RNA regulation, 2009 Experimental in vitro study for the implementation of air polishing during treatment of implanted surfaces in pa- tients with mucositis/peri-implantitis P. Paganin, C. Cortella, E .M. Polizzi, E. F. Gherlone Europerio 6th, June 4-6 2009 Stockholm, Sweden In vitro behaviour onto different titanium sureface of osteo- blast-like cells obtained from human dental pulp S. Tetè, F. Mastrangelo, V. Zizzari, G. D’Apolito, N. Fiorentino, U. Desiato, M.T. Sberna, R. Quaresima, L. Stuppia, R. Vinci, E. F. Gherlone Atti del 7th Annual Meeting of ISSCR Int. Society of Stem Cell Research, Barcellona July 2009 Novel Protocol of osteogenic differentiation from amnio- tic fluid cells S. Tetè, F. Mastrangelo, M. Tranasi, V. Zizzari, I. Antonucci, G. D’Apolito, T. Marchese, R. Vinci, L. Stuppia, E. F. Gherlone Atti del 7th Annual Meeting of ISSCR Int. Society of Stem Cell Research, Barcellona July 2009 Interfaccia osso - impianto nei differenti tipi di carico degli impianti dentali S. Tetè, G. D’Apolito, F. Mastrangelo, R. Vinci, E. F. Gherlone - Atti III Expo di Autunno Università della Lombardia, 27-28 Novembre 2009 Valutazione della capacità osteogenica di hafscs ottenute da liquido amniotico S. Tetè, U. Di Tore, V. Zizzari, L. Stuppia, F. Zarone, E. F. Gherlone - Atti III Expo di Autunno Università della Lombardia, 27-28 Novembre 2009 Analisi Morfostrutturale di Pamcs umane sulla superficie a deposizione elettrochimica FCC S. Tetè, A. De Carlo, E . Nargi, V. Zizzari, I. D’Alimonte, R. Ciccarelli, R. Vinci, E. F. Gherlone - Atti III Expo di Autunno Università della Lombardia, 27-28 Novembre 2009 L’innesto onlay autologo nelle atrofie localizzate B. Marcelli - QI Quintessenza Internazionale, anno 25 numero X Evaluation of Effects on bone Tissue of Different Osteotomy Techniques S. Tetè, R. Vinci, V. Zizzari, L. Cingano, R. Bollero, G. D’Apolito, L. Benzo, A. Dolci, C. Mortellaro, E. F. Gherlone - The Journal of Craniofacial Surgery vol. 20 n. 5 September 2009 Osteotomie eseguite con Piezosurgery: analisi biomole- colare degli effetti sul tessuto osseo S. Tetè, R. Vinci, F. Mastrangelo, U. Desiato, V. Zizzari, N. Fiorentino, L. Renzo, E. F. Gherlone Atti III Expo di Autunno Università della Lombardia, 27-28 Novembre 2009 La chirurgia Orale piezoelettrica M. Pasi, R. Vinci, D. Di Stefano, E. F. Gherlone IOS Italian Oral Surgery 5/2008 In vitro evaluation of osteoblast-like cells from different sources F. Mastrangelo, M. Tranasi, V. Zizzari, D. Farronato, T. Traini, R. F. Grassi, L. Stuppia, S. Tetè Atti del 86th General Session of International Association of Dental Research ( I.A.D.R.) Toronto, 2-5 Giugno 2008 A macro-and nanostructure evaluation of a Novel Dental Implant S. Tetè, F. Mastrangelo, T. Traini, R. Vinci, G. Sammartino, G. Marenzi, E. F. Gherlone - Implant Dentistry vol.17n.3 2008 Calvarial versus lliac Crest for Autologous bone graft material for a Sinus lift procedure: a Histomorphometric Study R. Crespi, R. Vinci, P. Capparè, E. F. Gherlone, G. E. Romanos - JOMI The International Journal of Oral & Ma- xillofacial - Implants, a.2007 vol. 22 n. 4 A Randomized Prospective Multicenter Trial Evaluating the Platform-Switching Technique for Preventing Po- strestorative Crestal Bone Loss L. Prosper, S. Redaelli, M. Pasi, F. Zarone, G. Radaelli, E. F. Gherlone Le tecniche piezoelettriche, recentemente impiegate in chirurgia dei mascellari, consentono osteotomie precise e sicure nel rispetto delle strutture ossee R. Vinci - Dental Cube 2 -Marzo 2007 Influenza del Desametasone nella germectomia piezoelettrica studio clinico controllato M. Del Brutto, C. Vianale, R. Mazzanti Poster I Expo di Autunno I Dicembre 2007 Valutazione del comportamento di osteoblasti derivanti da cellule staminali di liquido amniotico su differenti superfici implantari A. Desiderio, A. D’Incecco, L. Stuppia I. Antonucci, S. Tetè - Atti I Expo di Autunno Università della Lombardia - 1 Dicembre 2007 Evaluation of surface nano-topographic effect on afscells growth A. Desiderio, F. Mastrangelo, T. Traini, L. Stuppia, G. Sammartino, S. Tetè - Atti dell’Annual Meeting del I.A.D.R. International Association of Dental Research, Continental Divi- sion Thessaloniki26-29 Settembre 2007 Impianto troncoconico con componente protesica sotto- dimensionata per mantenere l’osso crestale L. Prosper, S. Redaelli, A. D’Addona, E. F. Gherlone Poster 13° Congresso Nazionale del Collegio dei Docenti di Odontoiatria , Roma 5-8 Aprile 2006 Passivazione della protesi implanto - supportata L. Prosper, S. Redaelli, T. D’Alicandro, A. D’Addona, E. F. Gherlone - Implantologia Orale: rivista di clinica, ricerca, qualità anno 8, n. 5 2005 Stabilizzazione della protesi mediante ancoraggio con mini impianti in pazienti con edentulia totale inferiore e atrofia del processo alveolare D.Perazzolo, E.Cavalieri, S.Piovan, E.Stellini, E. D’Andrea Poster 12° Congresso Nazionale Collegio dei Docenti di Odontoiatria, Roma - Palazzo dei Congressi 16-17-18-19 Marzo 2005 Follow-up a 4 anni di impianti post-estrattivi a diametro maggiorato L.Prosper, S.Redaelli, A.D’Addona, E.F.Gherlone - Poster N° 486 - 11° Congresso Nazionale - Collegio dei Docenti di Odontoiatria, 2004 Follow-up a 4 anni di impianti con diametro maggiore inseriti in alveoli di recente estrazione in combinazione con una membrana riassorbibile o con un materiale al- loplastico riassorbibile L.Prosper, E.F.Gherlone, S.Redaelli, M.Quaranta QE Implantologia la Rivista per il Clinico anno 2 - Aprile 2004 4 Year follow-up of larger diameter implants placed in fresh extraction sockets using a resorbable membrane or resorbable alloplastic material L.Prosper, E.F.Gherlone, S.Redaelli, M.Quaranta JOMI - The International Journal of Oral & Maxillofacial Im- plants, vol. 18 - 6 - 2003 A system for the diagnosis, placement, and prosthetic restoration of root form implants (U.S. Patent # 5,769,636) - F.Di Sario, Journal of PROSTHODONTICS, vol. 12 - 1 March - 2003 Sistema implantare WINSIX: Case-Report di un mo- noimpianto post-estrattivo in zona esteticaL.Prosper - QO Quintessenza Odontotecnica, anno 19, Marzo 2002 Verona Osteointegrazione a 5 anni di impianti sabbiati o sab- biati e mordenzati ritenenti protesi parziali fisse L.Prosper, F.Di Carlo, I.Vozza, M.Quaranta QI Quintessence International I - 2002 La passivazione implantare diretta secondo la metodica Free Tense TM Winsix Ltd, London, UK S.Redaelli, L.Prosper, E.Gherlone, A.D’Addona - 2002 Il carico immediato: studio prospettico e comparativo tra due diverse metodiche terapeutiche S.Redaelli - 2001 Clinical trial on osseointegration using sandblasted or sandblasted and acidetched implants S.Redaelli, L.Prosper, F. Di Carlo, A.Daddona, M.Quaranta - 2001 Implant-retained mandibolar overdentures with imme- diate loading: clinical and histological study G.Pompa, M.Cassetta, I.Vozza, R.Scaringi, M.Quaranta JDR, Journal of Dental research vol. 80, March 2001 Healing period of titanium implants with sandblasted and acid-etched surface L.Prosper, F. Di Carlo, S.Redaelli, R.Scaringi, M.Quaranta 3° World Congress of Osteointegration 2001 Tempo di guarigione ossea per impianti di titanio con superficie sabbiata o superficie sabbiata e mordenzata L.Prosper, F Di Carlo, S.Redaelli, G.Redaelli, R.Scaringi, M.Quaranta - (IJP La rivista Internazionale di Odontoiatria Protesica, vol.13 1 - 2000 Using of Gore Resolut Membrane in 223 post-extraction WINSIX Implants L. Prosper, S.Redaelli, G.Pompa, A.Palattella, M.Quaranta Atti 4TH Joint meeting 24-27 August 2000, Warsaw - Poland Gore Resolut membrane and implantation below the crest in postextraction surgery F. di Carlo, L.Prosper, S.Redaelli, I.Guadagno, M.Quaranta - anno 2000 Analisi in vivo su tre superfici implantari: valutazio- ne istomorfometrica - S.Redaelli, Prosper, F.Di Carlo, A.Scarano, I.Vozza - anno 2000 Cod. Ed.1/ITA/IX-2014

WINSIX MACHINED - BioSAFin · Crestal bone remodeling around platform switched, im-mediately loaded implants placed in sites of previous failures A.Quaranta, A.Cicconetti, L.Battaglia,

  • Upload
    others

  • View
    7

  • Download
    0

Embed Size (px)

Citation preview

Page 1: WINSIX MACHINED - BioSAFin · Crestal bone remodeling around platform switched, im-mediately loaded implants placed in sites of previous failures A.Quaranta, A.Cicconetti, L.Battaglia,

WINSIX®

MACHINED• ImpIanto KT machIned• ImpIanto CoNICo machIned

www.implantologiawinsix.comApp Store Google play

I dispositivi medici a marchio WINSIX® sono marcati CE (Classe I) e CE0476 (Classe IIA e IIB) in conformità alla Direttiva Dispositivi Medici 93/42/CEE e s.m.i.

WINSIX®

Sedi BIOSAF IN in ITALIA:

60131 ANCONAvia Tiraboschi 36/G

20060 MILANOTrezzano Rosa, via Cagliari, 32/44

tel. +39 071 2071897 - fax +39 071 203261info@biosa�n.com - assistenzaclienti@biosa�n.comwww.biosa�n.com

Principale Bibliografia di Riferimento del Sistema WINSIX®

An In Vitro Evaluation of Heat Production during Oste-otomy preparation for Dental Implants with compressi-ve Osteotomes - A.Quaranta, S.Andreana, L.Spazzafumo, M.Piemontese - Implant Dentistry Vol.22 N°2 - 2013

Maxillary sinus augmentation procedures through equi-ne-derived biomaterial or calvaria autologous bone: im-munohistochemical evaluation of OPG/RANKL in humansS.Tetè, R.Vinci, V.L.Zizzari, S.Zara, V.La Scala, A.Cataldi, E.F.Gherlone, A.Piattelli - European Journal of Histochemistry Vol.57: e10 - 2013

Airpolishing: protocollo sperimentale di studio in vitro per la gestione dei pazienti implantari affetti da mucosite e perimplantite - P. P. Paganin - L’igienista moderno Marzo 2013

Crestal bone remodeling around platform switched, im-mediately loaded implants placed in sites of previous failuresA.Quaranta, A.Cicconetti, L.Battaglia, M.Piemontese, G.PompaI.Vozza - European Journal of Inflammation Vol.10 N°2 Accepted July 30 - 2012

Use of Piezosurgery During Maxillary Sinus Elevation: Clinical Results of 40 Consecutive CasesM. Cassetta, L. Ricci, G. Iezzi, S. Calasso, A. Piattelli, V. PerrottiThe International Journal of Periodontics & Restorative Dentistry Vol. 32 N°6 - 2012

Macroscopic and microscopic evaluation of a new im-plant design supporting immediately loaded full arch rehabilitation.S.Tetè, V. Zizzari, A. De Carlo, B.Sinjari, E. GherloneAnnali di Stomatologia. Vol. 3, n. 2 - 2012.

Injectable Magnesium - Enriched Hydroxyapatite Putty in Peri- Implant Defects: A Histomorphometric Analysis in PigsR. Crespi, P. Capparè, A. Addis, E. F. Gherlone - The International Journal of Oral & Maxillofacial Implants Vol 27, N° 1 - 2012

TEETH JUST ON SIX: Riabilitazione Implantoprotesica nei casi di Edentulia completa: un approccio diagnostico - terapeutico integratoM. Manacorda, R. Vinci, M. Pasi, E. F. GherloneOdontoiatria, Rivista Amici di Brugg n°.1, anno 30°- Maggio - 2011

Long-Term Evaluation of Maxillary Reconstruction by Iliac Crest Bone Graft: A Morphologic and Immunohisto-chemical StudyS. Tetè, R. Vinci, S. Zara, V. Zizzari, A. De Carlo, G. Falco, D. Tripodi, A. Cataldi, C. Mortellaro, E. F. GherloneThe Journal of Craniofacial Surgery Vol. 22, N°5 - Sept. 2011

Immunohistochemical analysis of matrix metalloprotei-nase-9, vascular endothelial growth factor, bone sialo-protein and i-nitric oxide synthase in calvaria vs. iliac crest bone grafts. S Tetè, S Zara, VL Zizzari, A De Carlo, R Vinci, A Cataldi,E. Gherlone -Clinical Oral Implants Research.Vol. 23, n. 11 - 2011.

Microcomputed and Histologic Evaluation of Calvarial Bone Grafts: A pilot Study in HumansR. Vinci, A. Rebaudi, P. Capparè, E. F. Gherlone - The International Journal of Periodontics & Restorative Dentistry Vol.31, N° 4 2011

Tecniche Chirurgiche PiezoelettricheR. Vinci, M. Pasi, S. Tetè, E. F. GherlonePanorama Dental – Sept. 2011

Ostheosynthesis plates, screws, xenogenic graft and re-sorbable barriers for preimplant and peri-implant surgeryG. M. Rauso, N. Nesi, L. Fragola, M. Santagata, V. Santillo,R. Rauso - Minerva Stomatologica - 2010, 59:00-00

Utilizzo del Mucotomo per il rialzo del seno mascellare con approccio crestale: Report preliminareUse of the circular soft-tissue punch in maxillary sinus lifts with a crestal approach: a preliminary reportF. Vannini, M. Nardone - Italian Oral Surgery 2010; 9 (6):1-14

Lembo di bolla di Bichat associato al lembo di Reh-rmann nella correzione plastica di ampia fistola oro antrale in paziente trattata con bifosfonati: Case Report M. Del Brutto, G .Alfieri, G. Mariani, C. Vianale, R .Mazzanti,G. Sammartino - Sessione Poster- Roma 18-19-20 Febbraio 2010

Difetti di spessore crestali: Utilizzo della tecnica Split CrestB. Marcelli, A. Delli Carpini, E. Coccia, M .ProcacciniSessione Poster-Roma 18-19-20 Febbraio 2010

Influence of Novel Nano-Titanium Implant Surface on Human Osteoblast Behavior and GrowthS. Tetè, F. Mastrangelo, R. Quaresima, R. Vinci, G.Sammartino,L. Stuppia, E. F. Gherlone - Implant Dentistry, Vol.19, N° 6 2010

Chiave dinamometrica digitale: applicazioni in Implanto- protesi L. Prosper, M. Cappello, C. A. Cortella, T. D’Alicandro,E. F. Gherlone - QI Quintessenza Internazionale, anno 26n. 1 Gennaio/Marzo 2010

L’Impiego della teca cranica a scopo implantoprotesicoE. F. Gherlone, R. Vinci, L. D’AversaOral & Implantology Anno II N°2/ 2009

Effect of Implant Angulation, Connection Length, and Im-pression Material on the Dimensional Accuracy of Implant Impressions: An In Vitro Comparative StudyR. Sorrentino, E. F. Gherlone, G. Calesini, F. Zarone Clinical implant dentistry and related Research, 2009

A Randomized Prospective Multicenter Trial Evaluatingthe Platform-Switching Technique for Prevention ofPostrestorative Crestal Bone LossL. Prosper, S. Redaelli, M. Pasi, F. Zarone, G. Radaelli,E. F. Gherlone - JOMI The international Journal of Oral &Maxillofacial - Implants – vol. 24 n. 2, 2009

Isolation of osteogenic progenitors from human amnio-tic fluid using a single step culture protocolI. Antonucci, I. Iezzi, E. Morizio, F. Mastrangelo,A. Pantalone,M. Mattioli Belmonte, A. Gigante, V. Salini, G. Calabrese, S. Tetè, G. Palka, L. Stuppia - SILENCE a Journal of RNA regulation, 2009

Experimental in vitro study for the implementation of air polishing during treatment of implanted surfaces in pa-tients with mucositis/peri-implantitisP. Paganin, C. Cortella, E .M. Polizzi, E. F. Gherlone Europerio 6th, June 4-6 2009 Stockholm, Sweden

In vitro behaviour onto different titanium sureface of osteo-blast-like cells obtained from human dental pulpS. Tetè, F. Mastrangelo, V. Zizzari, G. D’Apolito, N. Fiorentino, U. Desiato, M.T. Sberna, R. Quaresima, L. Stuppia, R. Vinci, E. F. Gherlone Atti del 7th Annual Meeting of ISSCR Int. Society of Stem Cell Research, Barcellona July 2009

Novel Protocol of osteogenic differentiation from amnio-tic fluid cellsS. Tetè, F. Mastrangelo, M. Tranasi, V. Zizzari, I. Antonucci, G. D’Apolito, T. Marchese, R. Vinci, L. Stuppia, E. F. Gherlone Atti del 7th Annual Meeting of ISSCR Int. Society of Stem Cell Research, Barcellona July 2009 Interfaccia osso - impianto nei differenti tipidi carico degli impianti dentaliS. Tetè, G. D’Apolito, F. Mastrangelo, R. Vinci, E. F. Gherlone - Atti III Expo di Autunno Università dellaLombardia, 27-28 Novembre 2009

Valutazione della capacità osteogenicadi hafscs ottenute da liquido amniotico S. Tetè, U. Di Tore, V. Zizzari, L. Stuppia, F. Zarone,E. F. Gherlone - Atti III Expo di Autunno Università dellaLombardia, 27-28 Novembre 2009

Analisi Morfostrutturale di Pamcs umane sullasuperficie a deposizione elettrochimica FCCS. Tetè, A. De Carlo, E . Nargi, V. Zizzari, I. D’Alimonte,R. Ciccarelli, R. Vinci, E. F. Gherlone - Atti III Expo di Autunno Università della Lombardia, 27-28 Novembre 2009

L’innesto onlay autologo nelle atrofie localizzateB. Marcelli - QI Quintessenza Internazionale, anno 25 numero X

Evaluation of Effects on bone Tissue ofDifferent Osteotomy TechniquesS. Tetè, R. Vinci, V. Zizzari, L. Cingano, R. Bollero,G. D’Apolito, L. Benzo, A. Dolci, C. Mortellaro, E. F. Gherlone - The Journal of Craniofacial Surgery vol. 20n. 5 September 2009

Osteotomie eseguite con Piezosurgery: analisi biomole-colare degli effetti sul tessuto osseoS. Tetè, R. Vinci, F. Mastrangelo, U. Desiato, V. Zizzari, N. Fiorentino, L. Renzo, E. F. GherloneAtti III Expo di Autunno Università della Lombardia,27-28 Novembre 2009

La chirurgia Orale piezoelettricaM. Pasi, R. Vinci, D. Di Stefano, E. F. GherloneIOS Italian Oral Surgery 5/2008

In vitro evaluation of osteoblast-like cells from different sourcesF. Mastrangelo, M. Tranasi, V. Zizzari, D. Farronato, T. Traini,R. F. Grassi, L. Stuppia, S. Tetè Atti del 86th General Session of International Association of Dental Research ( I.A.D.R.) Toronto, 2-5 Giugno 2008

A macro-and nanostructure evaluation ofa Novel Dental ImplantS. Tetè, F. Mastrangelo, T. Traini, R. Vinci, G. Sammartino,G. Marenzi, E. F. Gherlone - Implant Dentistry vol.17n.3 2008

Calvarial versus lliac Crest for Autologous bone graft material for a Sinus lift procedure:a Histomorphometric StudyR. Crespi, R. Vinci, P. Capparè, E. F. Gherlone,G. E. Romanos - JOMI The International Journal of Oral & Ma-xillofacial - Implants, a.2007 vol. 22 n. 4

A Randomized Prospective Multicenter Trial Evaluating the Platform-Switching Technique for Preventing Po-strestorative Crestal Bone LossL. Prosper, S. Redaelli, M. Pasi, F. Zarone, G. Radaelli, E. F. Gherlone

Le tecniche piezoelettriche, recentemente impiegate in chirurgia dei mascellari, consentono osteotomie precise e sicure nel rispetto delle strutture osseeR. Vinci - Dental Cube 2 -Marzo 2007

Influenza del Desametasone nella germectomiapiezoelettrica studio clinico controllatoM. Del Brutto, C. Vianale, R. MazzantiPoster I Expo di Autunno I Dicembre 2007

Valutazione del comportamento di osteoblastiderivanti da cellule staminali di liquido amniotico sudifferenti superfici implantariA. Desiderio, A. D’Incecco, L. Stuppia I. Antonucci, S. Tetè - Atti I Expo di Autunno Università della Lombardia - 1 Dicembre 2007

Evaluation of surface nano-topographiceffect on afscells growthA. Desiderio, F. Mastrangelo, T. Traini, L. Stuppia,G. Sammartino, S. Tetè - Atti dell’Annual Meeting del I.A.D.R. International Association of Dental Research, Continental Divi-sion Thessaloniki26-29 Settembre 2007

Impianto troncoconico con componente protesica sotto-dimensionata per mantenere l’osso crestaleL. Prosper, S. Redaelli, A. D’Addona, E. F. Gherlone Poster 13° Congresso Nazionale del Collegio dei Docenti diOdontoiatria , Roma 5-8 Aprile 2006

Passivazione della protesi implanto - supportataL. Prosper, S. Redaelli, T. D’Alicandro, A. D’Addona,E. F. Gherlone - Implantologia Orale: rivista di clinica, ricerca, qualità anno 8, n. 5 2005

Stabilizzazione della protesi mediante ancoraggio con mini impianti in pazienti con edentulia totale inferiore e atrofia del processo alveolareD.Perazzolo, E.Cavalieri, S.Piovan, E.Stellini, E. D’AndreaPoster 12° Congresso Nazionale Collegio dei Docenti di Odontoiatria, Roma - Palazzo dei Congressi 16-17-18-19 Marzo 2005

Follow-up a 4 anni di impianti post-estrattivi a diametro maggioratoL.Prosper, S.Redaelli, A.D’Addona, E.F.Gherlone - Poster N° 486 - 11° Congresso Nazionale - Collegio dei Docenti di Odontoiatria, 2004

Follow-up a 4 anni di impianti con diametro maggiore inseriti in alveoli di recente estrazione in combinazione con una membrana riassorbibile o con un materiale al-loplastico riassorbibileL.Prosper, E.F.Gherlone, S.Redaelli, M.QuarantaQE Implantologia la Rivista per il Clinico anno 2 - Aprile 2004

4 Year follow-up of larger diameter implants placed in fresh extraction sockets using a resorbable membrane or resorbable alloplastic materialL.Prosper, E.F.Gherlone, S.Redaelli, M.QuarantaJOMI - The International Journal of Oral & Maxillofacial Im-plants, vol. 18 - N° 6 - 2003

A system for the diagnosis, placement, and prosthetic restoration of root form implants(U.S. Patent # 5,769,636) - F.Di Sario,Journal of PROSTHODONTICS, vol. 12 - N°1 March - 2003

Sistema implantare WINSIX: Case-Report di un mo-noimpianto post-estrattivo in zona esteticaL.Prosper - QO Quintessenza Odontotecnica, anno 19, Marzo 2002 Verona

Osteointegrazione a 5 anni di impianti sabbiati o sab-biati e mordenzati ritenenti protesi parziali fisseL.Prosper, F.Di Carlo, I.Vozza, M.QuarantaQI Quintessence International I - 2002

La passivazione implantare diretta secondo la metodica Free Tense TM Winsix Ltd, London, UKS.Redaelli, L.Prosper, E.Gherlone, A.D’Addona - 2002

Il carico immediato: studio prospettico e comparativo tra due diverse metodiche terapeuticheS.Redaelli - 2001

Clinical trial on osseointegration using sandblasted or sandblasted and acidetched implantsS.Redaelli, L.Prosper, F. Di Carlo, A.Daddona, M.Quaranta - 2001

Implant-retained mandibolar overdentures with imme-diate loading: clinical and histological studyG.Pompa, M.Cassetta, I.Vozza, R.Scaringi, M.QuarantaJDR, Journal of Dental research vol. 80, March 2001

Healing period of titanium implants with sandblasted and acid-etched surfaceL.Prosper, F. Di Carlo, S.Redaelli, R.Scaringi, M.Quaranta3° World Congress of Osteointegration 2001

Tempo di guarigione ossea per impianti di titanio consuperficie sabbiata o superficie sabbiata e mordenzataL.Prosper, F Di Carlo, S.Redaelli, G.Redaelli, R.Scaringi, M.Quaranta - (IJP La rivista Internazionale di Odontoiatria Protesica, vol.13 N° 1 - 2000

Using of Gore Resolut Membrane in 223 post-extraction WINSIX ImplantsL. Prosper, S.Redaelli, G.Pompa, A.Palattella, M.Quaranta Atti 4TH Joint meeting 24-27 August 2000, Warsaw - Poland

Gore Resolut membrane and implantation below the crest in postextraction surgeryF. di Carlo, L.Prosper, S.Redaelli, I.Guadagno, M.Quaranta- anno 2000

Analisi in vivo su tre superfici implantari: valutazio-ne istomorfometrica - S.Redaelli, Prosper, F.Di Carlo, A.Scarano, I.Vozza - anno 2000

BIOSAFIN_OK.indd 11 10/06/13 17.01

Cod

. Ed.

1/IT

A/IX

-201

4

Page 2: WINSIX MACHINED - BioSAFin · Crestal bone remodeling around platform switched, im-mediately loaded implants placed in sites of previous failures A.Quaranta, A.Cicconetti, L.Battaglia,

Nell’ottica di rendere la riabilitazione su impianti accessibile ad una fascia sempre più ampia di popolazione, la tecnologia WINSIX® rivolge le sue attenzioni a quei pazienti che in quanto parodontopatici o con propensione alle malattie parodontali, potrebbero dover rinunciare o vedere compromessa una riabilitazione su impianti. Così come ampiamente dimostrato in letteratura, la perimplantite è una malattia difficile da trattare ed è una delle principali cause del fallimento implantare, con gravi problematiche soprattutto nel successo a medio - lungo termine della riabilitazione implanto-supportata.

M ACH INED

Inserimento di un impianto WINSIX® Conico Machined

Impianto WINSIX® Conico Machinedinserito a livello crestale

Impianto WINSIX® Conico Machined a dimora con Vite di chiusura 3.8

Sutura

Microbiology and antimicrobial therapy of peri-implantitisMombelli A. - Periodontol 2000. 2002;28:177-89. Review.

Clinical trials on therapies for peri-implant infectionsLang NP, Mombelli A, Tonetti MS, Brägger U, Hämmerle CH.Ann Periodontol. 1997 Mar;2(1):343-56. Review.

Peri-implant diseases: Consensus Report of the Sixth European Workshop on Periodontology - Lindhe J1, Meyle J; Group D of European Workshop on Periodontology.J Clin Periodontol. 2008 Sep;35(8 Suppl):282-5. doi: 10.1111/j.1600-051X.2008.01283.x.

History of treated periodontitis and smoking as risks for implant therapyHeitz-Mayfield LJ, Huynh-Ba G. - Int J Oral Maxillofac Implants. 2009;24 Suppl:39-68. Review.

A comprehensive and critical review of dental implant prognosis in periodontally compromised partially edentulous patientsKaroussis IK, Kotsovilis S, Fourmousis I. - Clin Oral Implants Res. 2007 Dec;18(6):669-79. Epub 2007 Sep 13. Review.

Re-osseointegration on previously contaminated surfaces: a systematic reviewRenvert S, Polyzois I, Maguire R. - Clin Oral Implants Res. 2009 Sep;20 Suppl 4:216-27. doi: 10.1111/j.1600-0501.2009.01786.x. Review.

Periodontitis as a potential risk factor for peri-implantitisRenvert S, Persson GR. - J Clin Periodontol. 2009 Jul;36 Suppl 10:9-14. doi: 10.1111/j.1600-051X.2009.01416.x. Review.

Surgical treatment of peri-implantitisClaffey N, Clarke E, Polyzois I, Renvert S.J Clin Periodontol. 2008 Sep;35(8 Suppl):316-32

Non-surgical treatment of peri-implant mucositis and peri-implantitis: a literature reviewRenvert S, Roos-Jansåker AM, Claffey N.J Clin Periodontol. 2008 Sep;35(8 Suppl):305-15

Surgical treatment of peri-implantitisClaffey N1, Clarke E, Polyzois I, Renvert S.J Clin Periodontol. 2008 Sep;35(8 Suppl):316-32

Underlying mechanisms at the bone-surface interface during regenerationSchwartz Z1, Kieswetter K, Dean DD, Boyan BD.J Periodontal Res 1997 Jan;32(1 Pt 2):166-71.

Contaminated implant surfaces: an in vitro comparison of implant surface coating and treatment modalities for decontaminationDennison DK1, Huerzeler MB, Quinones C, Caffesse RG.J Periodontol 1994 Oct;65(10):942-8.

Experimental periodontitis and peri-implantitis in dogsCarcuac O, Abrahamsson I, Albouy JP, Linder E, Larsson L, Berglundh T. - Clin Oral Implants Res. 2013 Apr;24(4):363-71

Spontaneous progression of experimentalperi-implantitis at implants with different surface characteristics: an experimental study in dogsAlbouy JP, Abrahamsson I, Berglundh T.J Clin Periodontol. 2012 Feb;39(2):182-7.

Periodontitis, implant loss and peri-implantitis.A meta-analysisSgolastra F, Petrucci A, Severino M, Gatto R, Monaco A.Clin Oral Implants Res. 2013 Dec 31

Outcome of surgical treatment of peri-implantitis: results from a 2-year prospective clinical study in humansSerino G, Turri A. - Clin Oral Implants Res. 2011 Nov;22(11):1214-20

The effects of anti-infective preventive measures on the occurrence of biologic implant complications and implant loss: a systematic reviewSalvi GE, Zitzmann NU. - Int J Oral Maxillofac Implants. 2014

Systematic review of the effect of smoking on nonsurgical periodontal therapyLabriola A, Needleman I, Moles DR.Periodontol 2000. 2005;37:124-37. Review

Med Oral Patol Oral Cir Bucal 2011 Jul 1;16(4):e546-51.Meta-analysis on the survival of short implants.Menchero-Cantalejo E1, Barona-Dorado C, Cantero-Álvarez M, Fernández-Cáliz F, Martínez-González JM.

Longevity of dental implants in type IV bone:a systematic reviewGoiato MC, Dos Santos DM, Jr Santiago JF, Moreno A, Pellizzer EP. - Int J Oral Maxillofac Surg. 2014

Systematic review of survival rates for immediately loaded dental implantsDel Fabbro M, Testori T, Francetti L, Taschieri S, Weinstein R.Int J Periodontics Restorative Dent. 2006 Jun;26(3):249-63. Review.

Effect of maxillary sinus augmentation on the survival of endosseous dental implants. A systematic reviewWallace SS, Froum SJ.Ann Periodontol. 2003 Dec;8(1):328-43. Review.

La superficie liscia degli Impianti WINSIX® MACHINED viene trattata nelle diverse fasi di lavorazione, decontaminazione e sterilizzazione secondo i principi di processo corrispondenti ai massimi standard qualitativi, e sottoposta a controlli in rapporto 1:1 - non random - così come tutti gli Impianti del Sistema WINSIX®.

Le Certificazioni ISO 9001 e ISO 13485 di cui BioSAF IN beneficia sono normative che impongono un controllo costante dell’intero processo lavorativo, che viene periodicamente rivalutato ai fini dell’accreditamento, per la tutela dell’utilizzatore del dispositivo - l’Odontoiatra - e del fruitore finale - il Paziente.

Gli impianti WINSIX® MACHINED sono indicati per interventi chirurgici implantari endossei con l’obiettivo di una riabilitazione orale armonica ed efficace, sia funzionale che estetica.

Gli impianti WinSiX® maCHinED Sono partiColarmEntE inDiCati nEi SEGuEnti paziEnti:- Pazienti con storia di parodontite aggressiva- Pazienti fumatori con storia di parodontite

cronica e scarsa compliance- Pazienti a rischio di progressione della malattia

parodontale (con fattori di rischio ancora presenti dopo il trattamento parodontale)

- Pazienti incostanti alla terapia parodontale di mantenimento

- Pazienti con pregressa perimplantite- Pazienti che necessitano di grande rialzo del

seno mascellare con almeno 3 mm di osso residuo per la stabilità primaria.

ConicoMachined

KTMachined

IMPIANTO Conico MachinedCodice Articolol 33900M Ø 3.3 x 9 mml 33110M Ø 3.3 x 11 mml 33130M Ø 3.3 x 13 mml 33150M Ø 3.3 x 15 mm

l 38900M Ø 3.8 x 9 mml 38110M Ø 3.8 x 11 mml 38130M Ø 3.8 x 13 mml 38150M Ø 3.8 x 15 mm

l 45900M Ø 4.5 x 9 mml 45110M Ø 4.5 x 11 mml 45130M Ø 4.5 x 13 mml 45150M Ø 4.5 x 15 mm

IMPIANTO KT MachinedCodice Articolol 33009KTM Ø 3.3 x 9 mml 33011KTM Ø 3.3 x 11 mml 33013KTM Ø 3.3 x 13 mml 33015KTM Ø 3.3 x 15 mm

l 38009KTM Ø 3.8 x 9 mml 38011KTM Ø 3.8 x 11 mml 38013KTM Ø 3.8 x 13 mml 38015KTM Ø 3.8 x 15 mm

l 45009KTM Ø 4.5 x 9 mml 45011KTM Ø 4.5 x 11 mml 45013KTM Ø 4.5 x 13 mml 45015KTM Ø 4.5 x 15 mm

IMPIANTI WINSIX® MACHINED

TECNOLOGIA E SINERGIE WINSIX®

Gli impianti WINSIX® MACHINED sono disponibili nelle versioni KT e Conico nei diametri e lunghezze riportati in tabella. La loro macromorfologia replica gli Impianti WINSIX® KT e Conico già in utilizzo clinico da molti anni con Superficie Micro Rough Surface®, creando in tal senso sinergie opportune e funzionali nell’utilizzo del Kit Chirurgico, degli Strumenti da inserimento e degli

Accessori protesici: gli Odontoiatri già utilizzatori del Sistema Implantare WINSIX® possono inserire gli Impianti WINSIX® MACHINED nelle opzioni di scelta chirurgica, senza dover acquistare strumentario chirurgico specifico, in quanto il KIT CHIRURGICO WINSIX® dispone già di tutto il necessario.Le frese per l’Impianto Conico devono essere acquistate separatamente.

Frese Coniche WINSIX®Kit Chirurgico WINSIX®

protoCollo Di lavoropEr l’utilizzo Di impianti WinSiX® maCHinED

Scelta dell’Impianto•In caso di impianto singolo si consiglia di utilizzare impianti di diametro standard (3.8/4.5 mm), non corti

(quindi ≥ 9 mm) •In caso di riabilitazioni multiple queste limitazioni potrebbero essere non influenti.

Stabilità primaria e Carico ImmediatoParticolare attenzione deve essere riservata alla Qualità ossea D1 e D4 e alla stabilità primaria che deve essere raggiunta già nella fase d’inserimento degli impianti.Nell’arcata inferiore compresa tra i due fori mentonieri, la possibilità di eseguire un protocollo di carico immediato è molto alta per l’elevata stabilità primaria che è possibile raggiungere in quella zona (a fronte di un BIC inferiore rispetto agli impianti con superfici trattate e a un processo di “osteogenesi a distanza” e non un’ “osteogenesi a contatto” come nei rugosi).

Tempi di ProtesizzazioneLavorando con impianti con superficie macchinata i tempi di attesa per il carico protesico tendono ad allungarsi:•arcata superiore circa 6 mesi•arcata inferiore circa 4 mesiCREDITI MATERIALE FOTOGRAFICO: DR. EMIL SILD, LIBERO PROFESSIONISTA IN BOLOGNA

Bibliografia ImpIantI machIned

WINSIX®

In questi soggetti, in caso di perimplantite, eventuali riassorbimenti dei tessuti o esposizioni dell’impianto non comprometteranno l’integrazione e/o comunque faciliteranno il mantenimento a lungo termine dello stesso impianto, in quanto la superficie liscia riduce ai minimi termini l’infiltrazione e l’adesione batterica.

La superficie liscia degli Impianti WINSIX® MACHINED si basa su un processo di “osteogenesi a distanza” con un BIC (bone to implant contact) inferiore rispetto agli impianti con superfici ruvide e fondata sul principio dell’osteointegrazione per contatto.

GlI ImpIantI WInSIX® machIned - con SuperfIcIe lIScIa - Sono StatI appoSItamente SvIluppatI al fIne dI poter offrIre un’Importante opzIone rIabIlItatIva a queI SoGGettI che Il clInIco IndIvIdua (attraverSo uno ScreenInG SpecIfIco) facIlmente candIdatI a parodontopatIe, per caratterIStIche conGenIte o dI StIle dI vIta.