24
www.sommer-informatik.de 1 WinIso 2D The software to calculate two- dimensional heat flow rates First steps v.201601

WinIso 2D... 18 U f-value – Step 2 after selecting a cell to the right of the projected end of the profile, a mask for calculating opens by clicking on

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: WinIso 2D... 18 U f-value – Step 2 after selecting a cell to the right of the projected end of the profile, a mask for calculating opens by clicking on

www.sommer-informatik.de

1

WinIso 2DThe software to calculate two-

dimensional heat flow rates

First steps

v.201601

Page 2: WinIso 2D... 18 U f-value – Step 2 after selecting a cell to the right of the projected end of the profile, a mask for calculating opens by clicking on

www.sommer-informatik.de

2

Starter

v.201601

every task can get opened via the starter of WinIso 2D

open the task DXF.NET to convert a CAD drawing

Page 3: WinIso 2D... 18 U f-value – Step 2 after selecting a cell to the right of the projected end of the profile, a mask for calculating opens by clicking on

www.sommer-informatik.de

3

CAD-Conversion

the CAD-file can get loaded out of a directory at File Open

all steps of the macro get executed, and so the drawing automatically purged, by clicking on

v.201601

Page 4: WinIso 2D... 18 U f-value – Step 2 after selecting a cell to the right of the projected end of the profile, a mask for calculating opens by clicking on

www.sommer-informatik.de

4

Editing the purged drawing

by clicking on , the polygons get determined

material get selected at the upper drop-down menu

marked areas get filled with the selected material by clicking on

v.201601

Page 5: WinIso 2D... 18 U f-value – Step 2 after selecting a cell to the right of the projected end of the profile, a mask for calculating opens by clicking on

www.sommer-informatik.de

5

Filling areas and export

with the other buttons of the toolbar, enclosed air can get determined, polygons can get filled with random material or inside- and outside air can get set automatically

after all areas are filled with material, the file get exported to WinIso by clicking on

v.201601

Page 6: WinIso 2D... 18 U f-value – Step 2 after selecting a cell to the right of the projected end of the profile, a mask for calculating opens by clicking on

www.sommer-informatik.de

6

WinIso 2D Editor

v.201601

by doing this, the edited drawing get opened automatically at the WinIso 2D Editor

here, the construction can get analyzed directly or edited further

Page 7: WinIso 2D... 18 U f-value – Step 2 after selecting a cell to the right of the projected end of the profile, a mask for calculating opens by clicking on

www.sommer-informatik.de

7

Add material

a plurality of deposited materials according to valid European norms are located at Material Material database

these materials can get added to the project easily via double click

v.201601

Page 8: WinIso 2D... 18 U f-value – Step 2 after selecting a cell to the right of the projected end of the profile, a mask for calculating opens by clicking on

www.sommer-informatik.de

8

Fill material

a material has to get selected at the drop-down menu before to fill it into an area

by clicking on , the material get filled into the marked area

here, a standard gas get filled into the interspace between the panes, to improve the U-value of the window

v.201601

Page 9: WinIso 2D... 18 U f-value – Step 2 after selecting a cell to the right of the projected end of the profile, a mask for calculating opens by clicking on

www.sommer-informatik.de

9

Automatically split a higher number of columns and rows follows a more accurate calculation of the construction

therefore, WinIsooffers the function automatically split

the more cells get created by splitting, the much longer the program takes to calculate

v.201601

Page 10: WinIso 2D... 18 U f-value – Step 2 after selecting a cell to the right of the projected end of the profile, a mask for calculating opens by clicking on

www.sommer-informatik.de

10

Start calculation

the calculation with random temperatures starts by clicking on

afterwards different displays can be viewed

v.201601

Page 11: WinIso 2D... 18 U f-value – Step 2 after selecting a cell to the right of the projected end of the profile, a mask for calculating opens by clicking on

www.sommer-informatik.de

11

Isotherms Isotherms are curves of the same temperature

a good isotherm characteristic is a quality feature for a good construction element

the most valuable isotherms, like the 13°C isotherm, get distinguished in terms of color

v.201601

Page 12: WinIso 2D... 18 U f-value – Step 2 after selecting a cell to the right of the projected end of the profile, a mask for calculating opens by clicking on

www.sommer-informatik.de

12

Range of isotherms

the range of values of the isotherm can get adjusted with

a finer range is helpful, to find the coldest position of the construction afterwards (important for example to calculate the fRsi-factor)

v.201601

Page 13: WinIso 2D... 18 U f-value – Step 2 after selecting a cell to the right of the projected end of the profile, a mask for calculating opens by clicking on

www.sommer-informatik.de

13

Temperature fields

Additionally, the display of the temperature fields make sure that a graphical rework is available

v.201601

Page 14: WinIso 2D... 18 U f-value – Step 2 after selecting a cell to the right of the projected end of the profile, a mask for calculating opens by clicking on

www.sommer-informatik.de

14

Heat flow fields

Heat flow fields show, where the room for improvement of the construction element in reference to the heat transfer is

v.201601

Page 15: WinIso 2D... 18 U f-value – Step 2 after selecting a cell to the right of the projected end of the profile, a mask for calculating opens by clicking on

www.sommer-informatik.de

15

U-value the U-value is a rate, how much heat per unit area get lost through a construction element

due tu WinIso2D an extensive calculation per hand gets omitted

the U-value can get displayed by clicking on

v.201601

Page 16: WinIso 2D... 18 U f-value – Step 2 after selecting a cell to the right of the projected end of the profile, a mask for calculating opens by clicking on

www.sommer-informatik.de

16

fRsi-value

the fRsi-value provides the requirement for avoiding the mould growth according to DIN 4108-2

it gets measured where the lowest interior surface temperature of the wall or the frame is

the fRsi-value can get displayed by clicking on

v.201601

Page 17: WinIso 2D... 18 U f-value – Step 2 after selecting a cell to the right of the projected end of the profile, a mask for calculating opens by clicking on

www.sommer-informatik.de

17

Uf-value – Step 1

the Uf-value is the U-value of the frame and gets calculated according to EN ISO 10077-2

for determining this value manually, the glass has to get replaced by a calibrating paneeland the U-value of the paneel has to get determined

v.201601

Page 18: WinIso 2D... 18 U f-value – Step 2 after selecting a cell to the right of the projected end of the profile, a mask for calculating opens by clicking on

www.sommer-informatik.de

18

Uf-value – Step 2

after selecting a cell to the right of the projected end of the profile, a mask for calculating opens by clicking on

the position of the profile get defined at Calculation of (here on the left)

v.201601

the prior to this determined U-value for the panel gets adopted by clicking on Apply

after calculating, the Uf-value of the profile gets displayed

Page 19: WinIso 2D... 18 U f-value – Step 2 after selecting a cell to the right of the projected end of the profile, a mask for calculating opens by clicking on

www.sommer-informatik.de

19

Psi-value – Step 1

the Psi-value calculation assumes an Uf-value calculation

though it has to get calculated with the real glazing

the area between the panes get filled with 10077-air and afterwards replaced by a solid at Tools

here the known Ug-value get entered

v.201601

Page 20: WinIso 2D... 18 U f-value – Step 2 after selecting a cell to the right of the projected end of the profile, a mask for calculating opens by clicking on

www.sommer-informatik.de

20

Psi-value – Step 2

after selecting a cell to the right of the projected end of the profile, a mask for calculating opens by clicking on

at Calculation of, the Uf-Value of the profile and the U-value of the panel get entered

v.201601

the U-value of the panel can get determined as shown before and adopted by clicking on Apply

after calculating, the Psi-value of the profile gets displayed

Page 21: WinIso 2D... 18 U f-value – Step 2 after selecting a cell to the right of the projected end of the profile, a mask for calculating opens by clicking on

www.sommer-informatik.de

21

Uf- und Psi-Automatically

both Uf- and Psi-value calculation can be done completely automated

to this, it has to be clicked on respectively

the dimensions can get checked and, if necessary, adjusted

v.201601

Page 22: WinIso 2D... 18 U f-value – Step 2 after selecting a cell to the right of the projected end of the profile, a mask for calculating opens by clicking on

www.sommer-informatik.de

22

Uw-value

at 10077 Uw (EN 10077-1) the determined values can get used to calculate the Uw-value

all values has to get entered manually

the length of the glass edge gets calculated automatically out of the entered dimensions

after Calculating, the Uw-Value get displayed

v.201601

Page 23: WinIso 2D... 18 U f-value – Step 2 after selecting a cell to the right of the projected end of the profile, a mask for calculating opens by clicking on

www.sommer-informatik.de

23

Printout

at File Export different possibilities can be found to save and export the result

here an example of the word printout

v.201601

Page 24: WinIso 2D... 18 U f-value – Step 2 after selecting a cell to the right of the projected end of the profile, a mask for calculating opens by clicking on

www.sommer-informatik.de

24

Further information atwww.winiso2d.com

Sommer Informatik GmbH Sepp-Heindl-Str. 5 D-83026 Rosenheim Tel.: +49 (0)8031 2488-1 Fax: +49 (0)8031 2488-2