WindLDR Version 5.0 New Features. WindLDR Version 5.0. Supports FC5A Pentra series Simulation mode (OpenNet, FC4A, and FC5A) Online Edit mode (FC4A and FC5A) Monitor mode Improved Throughput monitoring Shortcuts Custom Monitor & Instruction Monitor dialog boxes - PowerPoint PPT Presentation
Citation preview
Think Automation and beyond…
WindLDR Version 5.0 New Features
Think Automation and beyond…
WindLDR Version 5.0 Supports FC5A Pentra series Simulation mode (OpenNet, FC4A, and FC5A) Online Edit mode (FC4A and FC5A) Monitor mode
– Improved Throughput monitoring
– Shortcuts
– Custom Monitor & Instruction Monitor dialog boxes Support HG3F/4F Ethernet Pass-Through Project Window Verify dialog box New shortcuts
Think Automation and beyond…
Simulation Mode
– Programs don’t have to be downloaded to be tested (download time is no longer needed).
– Wiring to inputs is unnecessary to test program inputs.
– Additional software package or installation is unnecessary.Just select Simulation from Online menu or click on button.
CPU module LEDs are shown in the status bar. PWR: Power LED RUN: Run LED ERR: Error LED STAT: Status LED
Power to the Simulator
Instructions are highlighted in green to differentiate from Monitor or Online Edit mode.
Think Automation and beyond…
Online Edit Mode (FC4A)
– Programs can be edited without stopping the PLC.– Up to 600 bytes of a program can be modified at a time.– To start Online Edit mode, open the program in the PLC, then select Online Edit
from Online menu or click on button.– Double-clicking on an instruction will open the edit instruction dialog box.
To modify operand values, press Ctrl-key, and then double click on an instruction.
Instructions are highlighted in aqua to differentiate from Monitor or Simulation mode.
After modifying program select Partial Program Download from the menu.
Tool bar icons for editing are available.
Think Automation and beyond…
Online Edit Mode (FC5A Pentra)
– Programs can be edited without stopping the PLC.– No size limitation to modify programs. – To download a program, select Run-time Program Download from Online menu.– Test Download function has been added.
Test programs can be downloaded to the PLC, tested, then either saved or discarded.
After modifying program, select Run-Time Program Download from the menu.
Download Test Program: Download a test program to the PLC.Confirm Test Program: Save the test program.Cancel Test Program: Discard the test program.
Think Automation and beyond…
Monitor Mode
– Communication Throughput for monitoring has been improved. Monitored values are updated faster than with version 4.x.
– Custom Monitor and Instruction Monitor dialog boxes have been added.(These dialog boxes will be shown in the following slides)
– Shortcuts Double click or press Enter on an instruction.
Normally Open, Normally Closed, OUT, OUTN, SET, or RST: Toggle the operand. Other instructions: Open Instruction Monitor dialog box.
Right Click menu Import operands in selected area to Custom Monitor dialog box. Start PLC, Stop PLC, Clear Error, or Clear All Data.
Think Automation and beyond…
Custom Monitor Dialog Box 1 Custom Monitor dialog box.
– Up to 30 operands can be registered in a dialog box.
– Custom Monitor dialogs can be saved with any name. Dialogs can then be opened as needed.
Saved custom monitor dialogs are listed under Custom Monitors folder in Project Window.To open a dialog, double click on it.
Think Automation and beyond…
Custom Monitor Dialog Box 2 Register operands with Drag & Drop.
(1) Select instructions or rungs.(2) Press Ctrl-key.(3) Left click on selected area, and drag
mouse cursor onto Custom Monitor dialog.
(4) Release mouse button.(5) All operands in selected area will be
registered to the Custom Monitor dialog.
Think Automation and beyond…
Custom Monitor Dialog Box 3 Shortcuts
– Cut, Copy, and Paste are supported.– Incremental Copy (Ctrl+Q).
Copy the current row, insert copied row into the following row, and increment the operand (in the copied row) by 1.
– Insert/Delete Row– Delete All
Delete all the registered operands in the dialog.– Sort
Registered operands can be sorted in alphabetical order.
– Up/down button for Incrementing operands.Shortcuts “+” and “-” also work.
Think Automation and beyond…
Instruction Monitor Dialog Box
– The monitor dialog box doesn’t have to be opened to input operands to change the values used in instructions.
– Simply double-click on an instruction or Press Enter on the instruction then the instruction monitor dialog box will appear.
Think Automation and beyond…
HG3F/4F Ethernet Pass-Through
– Using an HG3F/4F allows IDEC PLCs to be connected to the Ethernet without additional cost.
Ethernet
Router
Router
PC
HG3F/HG4F
•WindO/I NV2•WindLDR•WindSRV
OpenNet, FC4A, or FC5A
Pass-Through (Ethernet to Serial)
•Download•Upload•Debug•Monitor
Think Automation and beyond…
Project Window
– Custom monitor dialog boxes are shown in a list.
– All instructions available with selected PLC are listed.
The list of custom monitor dialog boxes are shown in Project Window.
The list of instructions available with selected PLC are shown.
Think Automation and beyond…
Program Verify
– Programs can be edited by opening the Verify dialog box.
– When clicking the Re-verify button, WindLDR verifies the current program and the previously uploaded program.Programs don’t have to be individually uploaded to be compared.
Think Automation and beyond…
Shortcuts
– Shift + M: Show/Hide Mnemonics– Shift + R: Select current rung– Shift + I: Open Invert NO/NC contacts dialog box – Shift + T: Switch Show tag names and Show allocation numbers– F4: Show/Hide Project Window– F5: Simulation– F7: Online Edit– F8: Monitor– Ctrl + F9: Convert, Download, and Monitor– F12: Partial Program Download (FC4A)– Menu: Start PLC, Stop PLC, Clear Error, and Clear All Data