WinCC Application Description - Siemens · PDF fileWinCC – Examples of integrated engineering with STEP 7 WinCC Application Description ... Examples of integrated engineering with

Embed Size (px)

Citation preview

  • Service & Support

    Answers for industry.

    WinCC Examples of integrated engineering with STEP 7 WinCC

    Application Description April 2009

  • Warranty, Liability and Support

    WinCC Examples of integrated engineering with STEP 7 Entry ID: 34995306

    Version V1.0 Issue 27.04.2009 2/230

    Cop

    yrig

    ht

    Sie

    men

    s A

    G C

    opyr

    ight

    200

    9 A

    ll rig

    hts

    rese

    rved

    Warranty, Liability and Support Note The Application Examples are not binding and do not claim to be

    complete regarding the configuration, equipping and any eventuality. The Application Examples do not represent customer-specific solutions. They are only intended to provide support for typical applications. You are responsible for ensuring that the described products are used correctly. These Application Examples do not relieve you of the responsibility of safely and professionally using, installing, operating and servicing equipment. When using these Application Examples, you recognize that we cannot be made liable for any damage/claims beyond the liability clause described. We reserve the right to make changes to these Application Examples at any time without prior notice. If there are any deviations between the recommendations provided in these Application Examples and other Siemens publications e.g. Catalogs the contents of the other documents have priority.

    We do not accept any liability for the information contained in this document.

    Any claims against us based on whatever legal reason resulting from the use of the examples, information, programs, engineering and performance data etc., described in this Application Example shall be excluded. Such an exclusion shall not apply in the case of mandatory liability, e.g. under the German Product Liability Act (Produkthaftungsgesetz), in case of intent, gross negligence, or injury of life, body or health, guarantee for the quality of a product, fraudulent concealment of a deficiency or breach of a condition which goes to the root of the contract (wesentliche Vertragspflichten). The damages for a breach of a substantial contractual obligation are, however, limited to the foreseeable damage, typical for the type of contract, except in the event of intent or gross negligence or injury to life, body or health. The above provisions do not imply a change of the burden of proof to your detriment.

    It is not permissible to transfer or copy these Application Examples or excerpts of them without first having prior authorization from Siemens Industry Sector in writing.

    If you have any questions concerning this document please e-mail us to the following address:

    [email protected]

    mailto:[email protected]

  • Preface

    WinCC Examples of integrated engineering with STEP 7 Entry ID: 34995306

    Version V1.0 Issue 27.04.2009 3/230

    Cop

    yrig

    ht

    Sie

    men

    s A

    G C

    opyr

    ight

    200

    9 A

    ll rig

    hts

    rese

    rved

    Preface

    Objective of the application This application is designed for users ...

    who gained initial experiences with WinCC already. It conveys knowledge about the interaction of the individual SIMATIC configuration tools and shows how their configuration can be made easier.

    Main contents of this application The following main points are discussed in this application:

    TIA

    Prerequisites

    Creating a Project

    Tags transfer

    Alarms

    System diagnostics

    Process diagnostics

    Trends

    User archives

    Time synchronization

    Basic Process Control

    Topics not covered by this application This application does not contain a description ...

    of the engineering tools used (STEP 7, WinCC).

    of the installation of STEP 7 or any required communication drivers.

    Previous knowledge in these fields is assumed.

    Validity The examples were created with WinCC V7.0 and STEP 7 V5.4.

    Industry Automation and Drives Technologies Service & Support Portal This entry is taken from the Internet Service Portal of Siemens AG, Industry Automation and Drives Technologies. The following link takes you directly to the download page of this document.

    http://support.automation.siemens.com/WW/view/en/34995306

    http://support.automation.siemens.com/WW/view/en/34995306

  • Content

    WinCC Examples of integrated engineering with STEP 7 Entry ID: 34995306

    Version V1.0 Issue 27.04.2009 4/230

    Cop

    yrig

    ht

    Sie

    men

    s A

    G C

    opyr

    ight

    200

    9 A

    ll rig

    hts

    rese

    rved

    Table of Contents

    Table of Contents ......................................................................................................... 4

    1 TIA .................................................................................................................... 8 1.1 What is TIA? ..................................................................................................... 8 1.2 Core statement ................................................................................................. 8 1.3 Details............................................................................................................... 9 1.4 Efficiency ........................................................................................................ 10 1.5 Vertical integration .......................................................................................... 11 1.6 Horizontal integration...................................................................................... 12 1.7 Added value.................................................................................................... 13 1.8 Further reading ............................................................................................... 14

    2 Prerequisites ................................................................................................. 15 2.1 Hardware requirements .................................................................................. 15 2.2 Software requirements.................................................................................... 15 2.3 Installing the software ..................................................................................... 15 2.4 Further instructions for installation.................................................................. 17 2.5 Language settings .......................................................................................... 18 2.6 Further reading ............................................................................................... 18

    3 Creating a Project ......................................................................................... 19 3.1 Introduction ..................................................................................................... 19 3.2 STEP 7 configuration...................................................................................... 20 3.2.1 Inserting the PLC ............................................................................................ 20 3.2.2 Inserting the PC station (WinCC).................................................................... 26 3.3 WinCC types................................................................................................... 30 3.4 Network configuration ..................................................................................... 31 3.5 Network connections ...................................................................................... 34 3.6 Compiling........................................................................................................ 35 3.6.1 What functions are executed during the compilation? .................................... 36 3.6.2 When should the compilation be carried out?................................................. 36 3.7 Configuration tool............................................................................................ 37 3.8 Further reading ............................................................................................... 38

    4 Tags ............................................................................................................... 39 4.1 Introduction ..................................................................................................... 39 4.2 Selecting STEP 7 symbols ............................................................................. 39 4.2.1 Principle of operation ...................................................................................... 41 4.2.2 Transfer of tags............................................................................................... 42 4.3 Automatic generation...................................................................................... 45 4.3.1 Principle of operation ...................................................................................... 45 4.3.2 Attributing individual tags in the symbol editor................................................ 46 4.3.3 Attributing of individual tags in a data block.................................................... 47

  • Content

    WinCC Examples of integrated engineering with STEP 7 Entry ID: 34995306

    Version V1.0 Issue 27.04.2009 5/230

    Cop

    yrig

    ht

    Sie

    men

    s A

    G C

    opyr

    ight

    200

    9 A

    ll rig

    hts

    rese

    rved

    4.3.4 Attributing input and output parameters of a function block............................ 50 4.3.5 Compiling............................................................