Upload
others
View
5
Download
0
Embed Size (px)
Citation preview
Sand Management
Well Testing Equipment
Technical Information
Well T
estingP
roduct Catalogue
Sand Management
Well Testing Equipment
Technical Information
Product C
atalogue
Excellence in Energy Services for over 100 years
web. www.huntingplc.com
Well Testing | Global Locations
United Kingdom
Badentoy AvenueBadentoy Industrial ParkPortlethen, AberdeenAB12 4YB, UK
T. +44 (0)1224 787000F. +44 (0)1224 787100
The Netherlands
Olieweg 101951 NHVelsen-NoordThe Netherlands
T. +31 (0) 251 229 219F. +31 (0) 251 210 654
Middle East
Building 23 Oilfields Supply CenterJebel Ali, P.O. Box 261929Dubai, UAE
T. +971 4 887 6850F. +971 4 887 6849
Asia Pacific
2 International Business Park #04-13/14 The Strategy Tower 1Singapore609930
T. +65 6933 1777F. +65 6933 1775
email. [email protected]
Well TestingProduct Catalogue
Contents
About Hunting
Introduction to Well Testing
Well Testing Product Range
Sand Management
Dual Pot Sand Filter (Type A)
Dual Pot Sand Filter (Type AH)
Dual Pot Sand Filter (Type B)
Dual Pot Sand Filter (Type B HPHT)
Cyclonic Wellhead Desander
Interchangeable Wellhead Desander
Well Testing Equipment
Choke Manifold
Wellhead Plug Catcher
Heat Exchanger (Standard Type)
Heat Exchanger (Container Type)
Vertical Surge Tank
Piping, Cross-overs And Instrumentation Packages
Technical Information
Dual Pot Sand Filter (Type A)
Dual Pot Sand Filter (Type AH)
Dual Pot Sand Filter (Type B)
Dual Pot Sand Filter (Type B HPHT)
Cyclonic Wellhead Desander
Interchangeable Wellhead Desander
Choke Manifold
Wellhead Plug Catcher
Heat Exchanger (Standard Type)
Heat Exchanger (Container Type)
Vertical Surge Tank
03
04
06
09
09
10
12
14
16
18
20
23
24
26
28
30
32
34
36
36
37
38
39
40
41
42
43
44
45
46
Well Testing | Contents
03
4000+EMPLOYEESWORLDWIDE
OVER 100 FACILITIES
24HOUR SUPPORT
API CERTIFIED
04
Hunting provides products and services to the world’s leading national, international energy companies and oil service companies enabling the extraction of oil and gas.
Manufacturing and sales locations are located in the key energy producing regions of the world.
Proprietary Technology
Hunting owns and develops proprietary patented products with a full range of applications below the wellhead including mud motors, premium connections, well perforating, logging and intervention tools.
Geographic Footprint
In strategic locations around the world Hunting owns and operates plants, properties and equipment, employing people to serve its global customers with local services and products.
Quality Assurance
It is essential that products and services provided by Hunting are designed and manufactured to conform to the agreed API, proprietary licensor, or other specification of the customer, meeting their needs and expectations the first time, every time.
It is the policy of Hunting that only the highest quality products and services, that meet all specification requirements, are provided to customers. Hunting operates a corporate Quality Management System covering all worldwide locations.
Hunting is committed to working safely in an environmentally responsible manner. These principles are fully integrated within our QMS that defines the company’s global operations.
• Connection Technology
• Dearborn
• Drilling Tools
• Electronics
• Manufacturing
• OCTG
• Specialty Supply
• Subsea Technology
• Titan
• Trenchless Products
• Well Intervention Equipment
Well Testing | About Hunting
Global Business Divsions
Health, Safety and Environment
Hunting is committed to achieving and maintaining the highest standards of safety for its employees, customers, suppliers and the public. All Hunting business units consciously operate in a manner that includes environmental matters as an integral part of its business plan.
Hunting’s aims are no accidents, no harm to people, and no damage to the environment. The Hunting goal is “Total Customer Satisfaction”.
05
Well Testing | Introduction to Well Testing
Hunting offers a unique combination of high quality manufactured well testing equipment and fabrication services.
Together with more than 30 years’ experience and using highly qualified welding processes, Hunting manufactures superior and customised well testing equipment.
Product Development
Hunting's engineering team have extensive experience in developing well test technology to meet the current industry challenges of managing solids production in high pressure and high flow-rate applications.
In addition to offering a wide range of industry standard products, the team is also ready to work closely with their client's on customized equipment to optimize a solution both in terms of cost and operational efficiency.
Engineering and Manufacturing Capabilities
All the detailed engineering studies including 2D/3D modeling and both FEM and CFD calculations in close co-operation with the manufacturing team.
The Hunting well test facility is able to engineer, fabricate, assemble and test their oilfield products under one roof meeting all the latest industry requirements for quality systems and manufacturing codes. These include:
• ISO 9001
• ISO 14001
• OHSAS 18001
• PED 97/23/EC
• ASME B31.3
• ASME VIII DIV.1, 2 & 3
• API 6A
• NACE MR-01-75/ISO 15156
• ATEX
• DNV 2.7-1 & DNV Lifting Appliance
• DNV OS-E-101
• NORSOK
06
07
Hunting’s extensive product portfolio includes sand filters, heat exchangers, choke manifolds, plug catchers and piping equipment.
Hunting’s dedicated and experienced well testing division is committed to improving well productivity in the most challenging environments.
Our success has been built around knowledge of the industry, correct planning, reliability of the equipment and ability to react to client requirements through timely engineering service and teamwork.
SAND MANAGEMENT
Hunting’s Well Testing division has developed a comprehensive sand
management solution with a range of safe and efficient high-pressure
sand removal technologies to address the industry challenge of
avoiding damage by erosion and plugging of process equipment during
well testing, frac flowback and clean-up operations.
Dual Pot Sand Filter (Type A)
Dual Pot Sand Filter (Type AH)
Dual Pot Sand Filter (Type B)
Dual Pot Sand Filter (Type B HPHT)
Cyclonic Wellhead Desander
Interchangeable Wellhead Desander
10
12
14
16
18
20
09
Dual Pot Sand Filter (Type A) Product Code | DSF-A
Well Testing | Sand Management
The Hunting Dual Pot Sand Filters are available in a broad range of sizes and configurations, up to 20,000psi WP. These products are in service globally with major production testing companies.
The principle of sand filtering is well understood, with the minimum size of the separated sand particles determined by the slot size in the sand filter in each pot which are available in a range from 100 to 800 microns. Continuous operation is achieved by switching the flow between the two pots and draining the collected sand from the bottom of the pot that is isolated from the flow.
The Type A Sand Filter is configured for the well to flow from the inside of the filter and the sand to collect therein. The sand can be removed with the filter or purged with water jets.
Optional equipment includes a sand flushing system using pressurized water injection through nozzles mounted on the pot vessel outside diameter and a sandbox for collection of the solids slurry exiting the 2” diameter drain valve.
For technical information see page 36
Wellhead sand filtration is established as an industry standard technique for sand and solids removal upstream of the choke manifold during well testing, frac-flowback and well clean-up operations.
Separates sand and other solid particles from the well stream
Dual pot system with high pressure by-pass and dual isolation valves
Switching flow between pots for continuous sand removal
Telescopic lifting support for convenient filter replacement
Quick union on pot vessels for rapid filter replacement & maintenance
Optional water jet sand flushing system
Optional Sandbox for sand disposal
Simple to operate
Eliminates erosion on choke manifold and downstream process equipment
Enables high rate well testing
Allows representative sand sampling and sand production rate estimation
FEATURES
BENEFITS
Dual P
ot S
and Filter (T
ype A
)
10
www.huntingplc.com
Dual Pot System
Allows continuous operation.
Upper Operations Deck
Allows easy access to remove quick union pot vessels during filter replacement.
Telescopic Lifting Support
Assists sand filter replacement.
11
Dual Pot Sand Filter (Type AH) Product Code | DSF-AH
The Hunting Dual Pot Sand Filters are available in a broad range of sizes and configurations, up to 20,000psi WP. These products are in service globally with major production testing companies.
The principle of sand filtering is well understood, with the minimum size of the separated sand particles determined by the slot size in the sand filter in each pot which are available in a range from 100 to 800 microns. Continuous operation is achieved by switching the flow between the two pots and draining the collected sand from the bottom of the pot that is isolated from the flow. The Type AH Sand Filter is configured for the well to flow from the inside of the filter and the sand to collect therein. The sand can be removed with the filter or purged with water jets.
The Type A-H is custom configured for use in an area where there are height restrictions and is both operated and transported in the horizontal position. It does not need to be swivelled upright for operation and can be used in areas where there are height restrictions.
Optional equipment includes a sand flushing system using pressurized water injection through nozzles mounted on the pot vessel outside diameter and a sandbox for collection of the solids slurry exiting the 2” diameter drain valve.
For technical information see page 37
Wellhead sand filtration is established as an industry standard technique for sand and solids removal upstream of the choke manifold during well testing, frac-flowback and well clean-up operations.
Separates sand and other solid particles from the well stream
Dual pot system with high pressure by-pass and dual isolation valves
Switching flow between pots for continuous sand removal
Horizontal operation and transportation without need to lift to vertical
Telescopic lifting support for convenient filter replacement
Quick union on pot vessels for rapid filter replacement & maintenance
Optional water jet sand flushing system
Optional Sandbox for sand disposal
Simple to operate
Eliminates erosion on choke manifold and downstream process equipment
Enables high rate well testing
Can be operated in areas with height restrictions
Allows representative sand sampling and sand production rate estimation
FEATURES
BENEFITS
Dual P
ot S
and Filter (T
ype A
H)
12
Well Testing | Sand Management
13
www.huntingplc.com
Lowered Upper Operations Deck
Horizontally configured valve manifolds and lowered sand filter vessels allow the upper operations deck to be lowered to work in areas with height restrictions.
Telescopic Lifting Supports
Assist sand filter replacement.
Dual Pot Sand Filter (Type B) Product Code | DSF-B
The Hunting Dual Pot Sand Filters are available in a broad range of sizes and configurations, up to 20,000psi WP. These products are in service globally with major production testing companies.
The principle of sand filtering is well understood, with the minimum size of the separated sand particles determined by the slot size in the sand filter in each pot which are available in a range from 100 to 800 microns. Continuous operation is achieved by switching the flow between the two pots and draining the collected sand from the bottom of the pot that is isolated from the flow. The Type B Sand Filter is configured for the well to flow through the sand filter from the outside with the sand collecting in the annulus between the vessel and filter.
The Sand Filter can be flushed be using a 2” line connection mounted on the inlet piping of vessel. The water flushes the outside diameter of the screen into a 2” drain line for collection of the solids.
For technical information see page 38
Wellhead sand filtration is established as an industry standard technique for sand and solids removal upstream of the choke manifold during well testing, frac-flowback and well clean-up operations.
Separates sand and other solid particles from the well stream
Dual pot system with high pressure by-pass and dual isolation valves
Switching flow between pots for continuous sand removal
Telescopic lifting support for convenient filter replacement
Quick union on pot vessels for rapid filter replacement & maintenance
Optional water jet sand flushing system
Simple to operate
Eliminates erosion on choke manifold and downstream process equipment
Enables high rate well testing
Allows representative sand sampling and sand production rate estimation
FEATURES
BENEFITS
Dual P
ot S
and Filter (T
ype B
)
14
Well Testing | Sand Management
Telescopic Lifting Supports
Assist sand filter replacement.
Upper Operation Deck
Allows easy access to remove quick union on pot vessels during filter replacement.
Dual Pot System
Allows continuous operation.
15
www.huntingplc.com
Dual Pot Sand Filter (Type B-HPHT) 4-1/16” 15KProduct Code | DSF-B-HPHT
The Hunting Dual Pot Sand Filters are available in a broad range of sizes and configurations, up to 20,000psi WP. These products are in service globally with major production testing companies.
The principle of sand filtering is well understood, with the minimum size of the separated sand particles determined by the slot size in the sand filter in each pot which are available in a range from 100 to 800 microns. Continuous operation is achieved by switching the flow between the two pots and draining the collected sand from the bottom of the pot that is isolated from the flow. The Type B-HPHT Sand Filter is configured for the well to flow through the sand filter from the outside with the sand collecting in the annulus between the vessel and filter.
The Sand Filter can be flushed be using a 2” line connection mounted on the inlet piping of vessel. The water flushes the outside diameter of the screen into a 3” drain line for collection of the solids.
For technical information see page 39
Wellhead sand filtration is established as an industry standard technique for sand and solids removal upstream of the choke manifold during well testing, frac-flowback and well clean-up operations.
Separates sand and other solid particles from the well stream
Dual pot system with high pressure by-pass and dual isolation valves
Switching flow between pots for continuous sand removal
Telescopic lifting support for convenient filter replacement
Hub connection on pot vessels for filter replacement & maintenance
Water connection for sand flushing
Optional Sandbox for sand disposal
Simple to operate
Eliminates erosion on choke manifold and downstream process equipment
Enables high rate well testing
Allows representative sand sampling and sand production rate estimation
FEATURES
BENEFITS
Dual P
ot S
and Filter (T
ype B
-HP
HT
)
16
Well Testing | Sand Management
17
www.huntingplc.com
Base Frame
Makes connection between the two skids.
20ft Container Skid
Comes with cornerpockets for transportation.
Filter Screen
Flows from inside to outside.
Cyclonic Wellhead Desander Product Code | CWD
Cyclonic de-sanders have a high efficiency of separation at high flow-rates with minimal pressure drop and can handle both a wider range of particle sizes and larger volumes of solids when compared to sand filters.
The cyclonic separator element is engineered from a highly wear-resistant alloy, is designed to be the only component potentially exposed to erosion and is simple to replace during operations if required.
The Hunting Cyclonic Wellhead Desander features a dual pot system which allows continuous sand separation and dumping by switching flow from one vessel to the other. The Hunting cyclonic technology has been independently flow loop tested to verify solids separation performance.
For technical information see page 40
The Hunting Cyclonic Wellhead Desander offers a robust high pressure solids management solution upstream of the choke manifold during well testing, frac-flowback and well clean-up operations.
Cyclone separator insert can be easily changed out
Dual pot system with high pressure by-pass and dual isolation valves
Lifting support for sand filter and cyclone separator interchange
High efficiency of solids separation (up to 99%) at high flow rates
Handles high flow rates with minimal back pressure
Continuous sand disposal by gravity and water flushing
Separates a wide range of particle sizes from the well stream
Eliminates erosion on choke manifold and downstream process equipment
Enables high rate well testing
Allows representative sand sampling and sand production rate estimation
FEATURES
BENEFITS
18
Well Testing | Sand Management
Cyclo
nic Wellhead
Desand
er
Dual Pot Systems
Allows continuous operation.
Cyclonic Access Point
Cyclonic separator element can be replaced during operations if required.
Upper Operations Deck
19
www.huntingplc.com
Interchangeable Wellhead DesanderProduct Code | IWD
Cyclonic de-sanders have a high efficiency of separation at high flow-rates with minimal pressure drop and can handle both a wider range of particle sizes and larger volumes of solids when compared to sand filters.
The cyclonic and sand filter separation techniques are considered complimentary and present a challenge to the well test service company in making an investment decision on one technique or the other without prior knowledge of the well conditions.
The Hunting Interchangeable Wellhead Desander features a dual pot system with interchangeable cyclone separators and sand filters offering the unique benefit of system configuration with both techniques to cover a wider range of well conditions from a single package.
The Hunting cyclonic technology has been independently flow loop tested to verify solids separation performance.
For technical information see page 41
The Hunting Interchangeable Wellhead Desander offers a flexible high pressure sand management solution upstream of the choke manifold during well testing, frac-flowback and well clean-up operations.
Cyclone separator insert is interchangeable with a sand filter
Dual pot system with high pressure by-pass and dual isolation valves
Lifting support for sand filter and cyclone separator interchange
High efficiency of solids separation (up to 99%) at high flow rates
Handles high flow rates with minimal back pressure
Continuous sand disposal by gravity and water flushing
Separates a wide range of particle sizes from the well stream
Flexible solids separation configuration on a single wellhead package
Eliminates erosion on choke manifold and downstream process equipment
Enables high rate well testing
Allows representative sand sampling and sand production rate estimation
FEATURES
BENEFITS
20
Well Testing | Sand Management
Interchangeab
le Wellhead
Desand
er
21
www.huntingplc.com
Sand Filter Configuration
The sand filter is set up in the Type A configuration.
Cyclone Configuration
The sand filter is removed, the cyclone separation inserted and
the pipework configured for cyclone operation.
The Hunting Cyclonic Desander Efficiency Calculator is an excel based software tool designed to aid our customers in selecting the most appropriate wellhead desanding method for their well test application.
The tool is based on published correlations and has been verified against both a CFD simulation of the Hunting cyclone and 3rd party flow loop tests.
The efficiency calculator allows our customers to run multiple scenarios varying inputs such as oil and gas flow rates, fluid properties and sand properties in order to evaluate their impact on solids separation performance.
23
WELL TESTING EQUIPMENT
Hunting’s extensive Well Testing product portfolio includes Heat
Exchangers, Choke Manifolds, Plug Catchers and Piping Packages.
Hunting’s dedicated and experienced Well Testing division is committed
to helping their customers improve well productivity in the most
challenging environments.
Choke Manifold
Wellhead Plug Catcher
Heat Exchanger (Standard Type)
Heat Exchanger (Container Type)
Vertical Surge Tank
Piping, Cross-overs And Instrumentation Packages
24
26
28
30
32
34
Choke Manifolds Product Code | WCM
Hunting can engineer, design and manufacture any choke manifold to the customer’s specific need’s including multiple valve and choke configurations, incorporating single or double pressure barrier philosophy and according to various industry-standard pressure and temperature ratings, pipe diameters and service requirements.
The Hunting standard choke manifold has three flow paths through:
• A fixed choke that provides accurate flow control for flow rate measurement under stable conditions.
• An adjustable choke used during well clean-up or drawdown operations until a stable flow condition has been achieved.
• A full-bore bypass that can be used when choking downstream at the heater or in open-flow conditions.
For technical information see page 42
The Choke Manifold is the primary well pressure and flow control package used during both offshore and onshore well testing, frac flow-back, well clean-up and early production operations.
Three flow paths through either a fixed or adjustable choke box or the full-bore bypass
Low-torque metal-to-metal sealing on all gate valves
Incorporates pressure ports and thermo-wells both upstream and downstream of the chokes
Isolation valves fitted both upstream and downstream of the chokes
Integral forklift pockets and four-point lifting sling provide safe handling options
Controls and reduces well pressure upstream of process equipment
Allows rapid fixed choke change-outs while the well remains flowing
Facilitates fluid sampling and both wellhead pressure and temperature measurement
Maximum operational flexibility with three flow-paths
FEATURES
BENEFITS
24
Well Testing | Well Testing Equipment
Cho
ke Manifo
lds
Adjustable Choke
Used during production clean up prior to establishing stable flow conditions.
Full-Bore Bypass Valve
Allows choking of the well at the heat exchanger.
25
www.huntingplc.com
Wellhead Plug CatcherProduct Code | WPC
It is positioned upstream of the wellhead sand separator or choke manifold to avoid damage and plugging of the downstream process.
The Hunting Plug Catcher consists of a horizontal mounted manifold with a catcher chamber with an internal perforated pipe to collect debris and a by pass line to allow the screen to be isolated, de-pressurised and the debris to be collected and measured as required.The perforating pipe is available in several sizes depending on the type of well debris to be removed. The drain feature allows debris such as frac balls to be removed without removing the perforated pipe.
Hunting plug catchers are available in a range of sizes, working pressures and configurations and can be customized to the clients’ requirements including dual catcher line designs to allow continuous debris removal and various sizes of perforated pipes.
For technical information see page 43
The Plug Catcher is designed to remove larger pieces of well debris from the well effluent during operations such as frac flowback, sand consolidation testing and completion clean-up after perforating or drilling out a bridge plug.
Catcher line with internal perforated pipe
By-pass line
Optional drain line for debris removal
In-line perforated pipes in various sizes
Prevents damage and plugging of the downstream equipment
Allows collection, inspection and measurement of larger well debris
FEATURES
BENEFITS
26
Well Testing | Well Testing Equipment
Wellhead
Plug
Catcher
In-Line Perforated Pipe
Catches debris and perforations can be sized according to custiomer specifications.
27
www.huntingplc.com
Support Beam
For screen replacement.
Catcher Vessel
Quick Union or Hub Vessel entrance
Heat Exchanger (Standard Type) Product Code | SHE-S
A separate steam generator supplies a constant flow of steam in contact with the coil to raise the temperature of the well effluent to prevent hydrate formation from plugging or restricting the flow and to improve separation and burner efficiency by reducing fluid viscosity and breaking down emulsions.
Hunting provides a customised design, taking account of thermal design features, high/low pressure limits, temperature range, product mix and fluid flow capacity. Hunting’s manufacturing flexibility enables them to supply heat exchangers for a variety of volume requirements.
The temperature of the well effluent downstream of the heat exchanger is monitored through a control-valve which then varies the steam flow into the vessel to maintain a pre-set temperature.
For technical information see page 44
The Heat Exchanger (Standard Type) is a skid-mounted steam vessel which contains a high pressure coil and choke through which the well stream can be diverted upstream of the separator.
Internal tubing coil for effluent flow inside pressurised steam outer shell
Automatic temperature control
Choke between inlet and outlet to allow preheating of effluent
Bypass manifold to avoid erosion in coils during well clean-up
Steam trap with steam condensate outlet
Rock-wool insulation on outer shell with aluminium jacket
Spares toolbox mounted in skid
Improved separation efficiency through viscosity reduction and breaking emulsions
Avoiding flow restriction from gas hydrate formation
Enabling well test operations where indirect-fired heaters are not permitted
FEATURES
BENEFITS
28
Well Testing | Well Testing Equipment
Heat E
xchanger (S
tandard
Typ
e)
Manual Choke
Is located between the two coils in order to have the fluid pre-heated to prevent the formation of hydrates.
By-Pass Valve
Isolates and by-passes internal coil during clean-up operations.
Pressure Relief Valve
The pressure relief valve is transport inside the frame and installed on the heat exchanger vessel prior to operations.
29
www.huntingplc.com
Heat Exchanger (Container Type)Product Code | SHE-C
The Container is designed to be shipped and handled like a standard 20 ft shipping container lowering the cost of transportation.
A separate steam generator supplies a constant flow of steam in contact with the coil to raise the temperature of the well effluent to prevent hydrate formation from plugging or restricting the flow and to improve separation and burner efficiency by reducing fluid viscosity and breaking down emulsions.
Hunting provides a customised design, taking account of thermal design features, high/low pressure limits, temperature range, product mix and fluid flow capacity. Hunting’s manufacturing flexibility enables them to supply heat exchangers for a variety of volume requirements.
The temperature of the well effluent downstream of the heat exchanger is monitored through a control-valve which then varies the steam flow into the vessel to maintain a pre-set temperature.
For technical information see page 45
The Heat Exchanger Container Type is a skid-mounted steam vessel which contains a high pressure coil and choke through which the well stream can be diverted upstream of the separator.
Internal tubing coil for effluent flow inside pressurised steam outer shell
Automatic temperature control
Choke between inlet and outlet to allow preheating of effluent
Bypass manifold to avoid erosion in coils during well clean-up
Steam trap with steam condensate outlet
Rock-wool insulation on outer shell with aluminium jacket
Spares toolbox mounted in skid
Improved separation efficiency through viscosity reduction and breaking emulsions
Avoiding flow restriction from gas hydrate formation
Enabling well test operations where indirect-fired heaters are not permitted
Packaged in industry standard 20 ft shipping container skid
FEATURES
BENEFITS
30
Well Testing | Well Testing Equipment
Heat E
xchanger (C
ontainer T
ype)
Shipping Frame
20ft shipping frame meets industry shipping container standard to reduce cost and complexity of shipping and handling.
Internal Adjustable Choke
Internal adjustable choke on tubing coil allows pre-heating of well effluent upstream of choke.
Insulated Vessel
Aluminium jacket protect rock-wool insulation on vessel steam.
31
www.huntingplc.com
Vertical Surge TankProduct Code | VST-A
Positioned downstream of the separator liquid outlet the VST is used to measure liquid flow rates and the combined shrinkage and meter factor. It can also be used as a second stage separator where a longer retention time is required.
A pressure relief valve and a high and low level alarm system prevent overpressurization and over-filling of the vessels during operations.
The VST can be manufactured with either a double or single compartment with either a sight glass or magnetic indicators to monitor liquid levels.
The Hunting VST is mounted in a protective frame manufactured according to the requirements of Det Norske Veritas (DNV) 2.7-1 and is designed for vertical operation and horizontal transportation.
For technical information see page 46
The Hunting vertical surge tank (VST) is a low-pressure vessel designed to store liquid hydrocarbons prior to disposal during both offshore and onshore well testing and clean-up operations.
Pressure retaining storage vessel to eliminate gas venting
Can be used as second stage separator
Single or twin compartment
Measures liquid flow rates, shrinkage and meter factors
Level monitoring by sight glass or magnetic indicators
By-pass manifold allows isolation from process flow
Access for internal inspection and maintenance
High and low level alarm in each compartment
Sampling, pressure and temperature ports
Improves oil and gas separation when a longer retention time is required
Pressurized storage improves burner efficiency during production disposal
Eliminates atmospheric venting during H2S production operations
FEATURES
BENEFITS
32
Well Testing | Well Testing Equipment
Vertical S
urge T
ank
33
www.huntingplc.com
Pressure Relief Valve
Prevents over pressurisation of the vessel during operations by venting gas through the installation's LP line.
Manhole Cover
Allows vessel internal access for cleaning, maintenance, inspecition and repair.
Piping, Crossovers and Instrumentation Packages
34
Dedicated and experienced well test equipment fabrication service
Certification and Testing according PED 97/23/EC / ASME B31.3 / NACE
On-time delivery reducing operational impact
High quality fabrication up to the latest industry standards
FEATURES
BENEFITS
Piping Packages
Configurations
• Flow-Lines• Elbows• Cross-Overs• Data Headers• Tee’s• Y-Pieces• Instrument Flanges• Cross-blocks• Test Caps
Connections
• API & ASTM Flanges• API Hubs• Grayloc & Vector Hubs• FMC & Anson Hammer Union
from Fig 206 to 2202
Supplies
• Gaskets• Seal Rings• Stud-bolts• API Clampsets• Grayloc & Vector Clampsets• Protectors
Crossover Packages
• Any combination of the connectors and more.
Instrumentation Packages
• Pressure Gauges• Block and Bleed
• Temperature Gauges • Needle Valves
Well Testing, frac flowback and clean-up operations both offshore and onshore need customised piping, cross-over and instrumentation packages to be professionally fabricated, often at very short notice, where any delay has a potentially high impact on the cost of the operation and reputation of the well testing service provider.
Building on more than 30 years industry experience, Hunting has managed the inventory of critical components, such as pipe connectors, and developed in-house skills in welding and fabrication to establish a reputation for outstanding on-time delivery for this niche service.
Hunting can provide a wide range of packages according to the customer’s requirements including Certification and Testing in accordance with PED 97/23/EC / ASME B31.3 / NACE. DNV-OS-E101.
Well Testing | Well Testing Equipment
35
Hunting can provide a wide range of packages according to the customer’s requirements including Certification and Testing in accordance with PED 97/23/EC / ASME / B31.3 / NACE / DNV-OS-E101.
www.huntingplc.com
Model Hunting DSF-A 5K Hunting DSF-A 10K Hunting DSF-A 15K Hunting DSF-A 20K
Service H2S H2S H2S H2S
Fluid Class DD DD DD DD
Working Pressure psi [bar] 5,000 [345] 10,000 [690] 15,000 [1035] 20,000 [1379]
Working Temperature °C [°F] -29 [0] up to 180 [350] -29 [0] up to 180 [350] -29 [0] up to 180 [350] -29 [0] up to 180 [350]
Filter Sizes [mu] 100 up to 800 100 up to 800 100 up to 800 100 up to 800
Filter Volume - liter 47 liter 47 liter 47 liter 47 liter
Filter Flow Direction inside → outside inside → outside inside → outside inside → outside
Maximum Filter ΔPpsi [bar] 1,500 [100] 1,500 [100] 2,755 [190] 2,755 [190]
Flow Capacity(1)
Gas, Mmscf [m³ / day] 25 [750.000] 50 [1.500.000] 75 [2.250.000] 100 [3.000.000]
Oil, bbls /day 5000 5000 5000 5000
Standard Connections(2)
Gas / Oil Inlet API Flange 3-1/8” 5K API Flange 3-1/16” 10K API Flange 3-1/16” 15K API Flange 3-1/16” 20K
Gas / Oil Outlet API Flange 3-1/8” 5K API Flange 3-1/16” 10K API Flange 3-1/16” 15K API Flange 3-1/16” 20K
Drain Union 2" Fig.1002 Union 2" Fig.1502 Union 2" Fig.2202 API Flange 2-1/16” 20K
Operational Footprint LxB cm 214 x 363 263 x 214 229 x 250 300 x 250
Transport Size LxBxH cm386 x 214 x 263Optional 20ft Container Skid(3)
410 x 214 x 263Optional 20ft Container Skid(3)
429 x 229 x 250 450 x 300 x 250
Weight, kg [lbm] 8000 [20,944] 9.500 [20,944] 15.300 [33,700] ±20.000 [44,095]
Certifications
Design Type Approval Type Approval Type Approval DVR
Manufacturing Declaration of Conformity Declaration of Conformity Declaration of Conformity Declaration of Conformity
Documentation Quality File Quality File Quality File Quality File
Applicable Codes
PED 97/23/EC PED 97/23/EC PED 97/23/EC PED 97/23/EC
ASME B31.3 ASME B31.3 ASME B31.3 ASME B31.3
ASME VIII div.2 ASME VIII div.2 ASME VIII div.3 ASME VIII div.3
API 6A API 6A API 6A API 6A
NACE MR 01-75 (ISO 15156-1,-2)
NACE MR 01-75 (ISO 15156-1,-2)
NACE MR 01-75 (ISO 15156-1,-2)
NACE MR 01-75 (ISO 15156-1,-2)
DNV 2.7-1 DNV 2.7-1 DNV 2.7-1 DNV 2.7-1
Dual Pot Sand Filter (Type A)
(1) Flow capacity is dependant on many factors. Please contact Hunting for advice.
(2) Connections cross-overs can be added as per customer requirements.
(3) Hunting has a Dual Pot Sand Filter Design inside a 20ft Container Skid.
36
DSF-A
T EC H N I C A L I N F O R M AT I O N
P R O D U C T CO D E
N OT E S
Model Hunting DSF-AH 5K Hunting DSF-AH 3-1/16 10K Hunting DSF-AH 4-1/16 10K
Service H2S H2S H2S
Fluid Class DD DD DD
Working Pressure psi [bar] 5,000 [345] 10,000 [690] 10,000 [690]
Working Temperature °C [°F] -29 [0] up to 180 [350] -29 [0] up to 180 [350] -29 [0] up to 180 [350]
Filter Sizes [mu] 100 up to 800 100 up to 800 100 up to 800
Filter Volume - liter 47 liter 47 liter 47 liter
Filter Flow Direction inside → outside inside → outside inside → outside
Maximum Filter ΔPpsi [bar] 1,500 [100] 1,500 [100] 1,500 [100]
Flow Capacity(1)
Gas, Mmscf [m³ / day] 50 [1.500.000] 50 [1.500.000] 100 [3.000.000]
Oil, bbls /day 5000 5000 10,000
Standard Connections(2)
Gas / Oil Inlet API Flange 5-1/8” 5K API Flange 3-1/16” 10K API Flange 4-1/16” 10K
Gas / Oil Outlet API Flange 5-1/8” 5K API Flange 3-1/16” 10K API Flange 4-1/16” 10K
Drain Union 3" Fig.1502 Union 3" Fig.1502 Union 3" Fig.1502
Operational Footprint LxB cm 425 x 245 425 x 245 425 x 245
Transport Size LxBxH cm 425 x 245 x 300 425 x 245 x 300 425 x 245 x 300
Weight, kg [lbm] 12.000 [26.455] 10.000 [30.864] 12.000 [30.864]
Certifications
Design Type Approval Type Approval Type Approval
Manufacturing Declaration of Conformity Declaration of Conformity Declaration of Conformity
Documentation Quality File Quality File Quality File
Applicable Codes
PED 97/23/EC PED 97/23/EC PED 97/23/EC
ASME B31.3 ASME B31.3 ASME B31.3
ASME VIII div.2 ASME VIII div.2 ASME VIII div.2
API 6A API 6A API 6A
NACE MR 01-75 (ISO 15156-1,-2)
NACE MR 01-75 (ISO 15156-1,-2)
NACE MR 01-75(ISO 15156-1,-2)
DNV 2.7-1 DNV 2.7-1 DNV 2.7-1
(1) Flow capacity is dependant on many factors. Please contact Hunting for advice.
(2) Connections cross-overs can be added as per customer requirements.
N OT E S
37
Dual Pot Sand Filter (Type AH)
DSF-AH
T EC H N I C A L I N F O R M AT I O N
P R O D U C T CO D E
Model Hunting DSF-B 10K Hunting DSF-B 10K HV
Service H2S H2S
Fluid Class DD DD
Working Pressure psi [bar] 10,000 [690] 10,000 [690]
Working Temperature °C [°F] -29 [0] up to 180 [350] -29 [0] up to 121 [250]
Filter Sizes [mu] 100 up to 800 100 up to 800
Filter Volume - liter 62 liter 82 liter
Filter Flow Direction outside → inside outside → inside
Maximum Filter ΔPpsi [bar] 1,500 [100] 1,500 [100]
Flow Capacity(1)
Gas, Mmscf [m³ / day] 50 [1.500.000] 100 [3.000.000]
Oil, bbls /day 5000 8000
Standard Connections(2)
Gas / Oil Inlet API Flange 3-1/16” 10K API Flange 4-1/16” 10K
Gas / Oil Outlet API Flange 3-1/16” 10K API Flange 4-1/16” 10K
Drain Union 2" Fig.1502 Union 2" Fig.1502
Operational Footprint LxB cm 240 x 277 250 x 280
Transport Size LxBxH cm 402 x 240 x 277 500 x 250 x 280
Weight, kg [lbm] 11.000 [24.250] 15.000 [33.069]
Certifications
Design Type Approval DVR
Manufacturing Declaration of Conformity Declaration of Conformity
Documentation Quality File Quality File
Applicable Codes
PED 97/23/EC PED 97/23/EC
ASME B31.3 ASME B31.3
ASME VIII div.2 ASME VIII div.2
API 6A API 6A
NACE MR 01-75 (ISO 15156-1,-2) NACE MR 01-75 (ISO 15156-1,-2)
DNV 2.7-1 DNV 2.7-1
(1) Flow capacity is dependant on many factors. Please contact Hunting for advice.
(2) Connections cross-overs can be added as per customer requirements.
N OT E S
38
Dual Pot Sand Filter (Type B)
DSF-B
T EC H N I C A L I N F O R M AT I O N
P R O D U C T CO D E
Model Hunting DSF-B 4-1/16” 15K
Service H2S
Fluid Class DD
Working Pressure psi [bar] 15,000 [1035]
Working Temperature °C [°F] -29 [0] up to 180 [350]
Filter Sizes [mu] 100 up to 800
Filter Volume - liter 82 liter
Filter Flow Direction inside → outside
Maximum Filter ΔPpsi [bar] 1,800 [125]
Flow Capacity(1)
Gas, Mmscf [m³ / day] 120 [3.400.000]
Oil, bbls /day 24.000
Standard Connections(2)
Gas / Oil Inlet API Flange 5-1/8” 15K
Gas / Oil Outlet API Flange 5-1/8” 15K
Water Flush API Flange 2-1/6” 15K
Drain API Flange 3-1/6” 15K
Operational Footprint LxB cm 515 x 290 (Base frame)
Transport Size LxBxH cm 2x 20ft Container (619x260x290) + Base frame
Weight, kg [lbm] 2x 16.000 [2x 35.000]
Certifications
Design Type Approval
Manufacturing Declaration of Conformity
Documentation Quality File
Applicable Codes
PED 97/23/EC
ASME B31.3
ASME VIII div.3
API 6A
NACE MR 01-75 (ISO 15156-1,-2)
DNV 2.7-1
DNV-OS-E101
NORSOK D-007, Z-015
(1) Flow capacity is dependant on many factors. Please contact Hunting for advice.
(2) Connections cross-overs can be added as per customer requirements.
N OT E S
39
Dual Pot Sand Filter (Type B-HPHT)
DSF-B-HPHT
T EC H N I C A L I N F O R M AT I O N
P R O D U C T CO D E
Model Hunting CWD 10K
Service H2S
Fluid Class DD
Working Pressure psi [bar] 10,000 [690]
Working Temperature °C [°F] -29 [0] up to 180 [350]
Sand Storage Volume, liter 2x 200 liter
Flow Capacity(1)
Gas, Mmscf [m³ / day] 50 [1.500.000]
Oil, bbls /day 5000
Standard Connections(2)
Unit Inlet API Flange 4-1/16” 10K
Cyclone Inlet API Flange 3-1/16” 10K
Drain Union 2" Fig.1502
Operational Footprint, LxB cm 244 x 244
Transport Size, LxBxH cm 6025 x 244 x 244 (20ft Container Skid)
Weight, kg [lbm] 16,000 [20,944]
Certifications
Design Type Approval
Manufacturing Declaration of Conformity
Documentation Quality File
Applicable Codes
PED 97/23/EC
ASME B31.3
ASME VIII div.2
API 6A
NACE MR 01-75 (ISO 15156-1,-2)
DNV 2.7-1
(1) Flow capacity is dependant on many factors. Please contact Hunting for advice.
(2) Connections cross-overs can be added as per customer requirements.
N OT E S
40
Cyclonic Wellhead Desander
CWD
T EC H N I C A L I N F O R M AT I O N
P R O D U C T CO D E
Model DSF-A 10K Cyclone upgrade Hunting IWD 10K
Service H2S H2S
Fluid Class DD DD
Working Pressure psi [bar] 10,000 [690] 10,000 [690]
Working Temperature °C [°F] -29 [0] up to 180 [350] -29 [0] up to 180 [350]
Filter Sizes [mu] 100 up to 800 100 up to 800
Filter Volume - liter 2x 47 liter 2x 47 liter
Cyclone Sand Volume - liter 2x 62 liter 2x 62 liter
Filter Flow Direction inside → outside inside → outside
Maximum Filter ΔPpsi [bar] 1,500 [100] 1,500 [100]
Flow Capacity(1)
Gas, Mmscf [m³ / day] 50 [1.500.000] 50 [1.500.000]
Oil, bbls /day 5000 5000
Standard Connections(2)
Gas / Oil Inlet API Flange 3-1/16” 10K API Flange 4-1/16” 10K
Gas / Oil Outlet API Flange 3-1/16” 10K API Flange 3-1/16” 10K
Drain Union 2" Fig.1502 Union 2" Fig.1502
Operational Footprint LxB cm 263 x 214 244 x 244
Transport Size LxBxH cm 410 x 214 x 263 Optional for 20ft Container Skid(3) 6025 x 244 x 244 (20ft Container Skid)
Weight, kg [lbm] 9.500 [20,944] 12.000 [26,455]
Certifications
Design Type Approval Type Approval
Manufacturing Declaration of Conformity Declaration of Conformity
Documentation Quality File Quality File
Applicable Codes
PED 97/23/EC PED 97/23/EC
ASME B31.3 ASME B31.3
ASME VIII div.2 ASME VIII div.2
API 6A API 6A
NACE MR 01-75 (ISO 15156-1,-2) NACE MR 01-75 (ISO 15156-1,-2)
DNV 2.7-1 DNV 2.7-1
(1) Flow capacity is dependant on many factors. Please contact Hunting for advice.
(2) Connections cross-overs can be added as per customer requirements.
(3) Hunting has a Dual Pot Sand Filter Design inside a 20ft Container Skid.
N OT E S
41
Interchangeable Wellhead Desander
IWD
T EC H N I C A L I N F O R M AT I O N
P R O D U C T CO D E
Model WCM 5K WCM 10K WCM 15K WCM 20K
Service H2S H2S H2S H2S
Fluid Class DD DD DD DD
Working Pressure psi [bar] 5,000 [345] 10,000 [690] 15,000 [1035] 20,000 [1379]
Working Temperature °C [°F] -29 [0] up to 180 [350] -29 [0] up to 180 [350] -29 [0] up to 180 [350] -29 [0] up to 180 [350]
Flow Capacity(1)
Gas, Mmscf [m³ / day] 25 [750.000] 50 [1.500.000] 75 [2.250.000] 75 [2.250.000]
Oil, bbls /day 5000 5000 5000 5000
Standard Connections(2)
Gas / Oil Inlet API Flange 3-1/8” 5K API Flange 3-1/16” 10K API Flange 3-1/16” 15K API Flange 3-1/16” 20K
Gas / Oil Outlet API Flange 3-1/8” 5K API Flange 3-1/16” 10K API Flange 3-1/16” 15K API Flange 3-1/16” 20K
Operational Footprint LxB cm Dimensions and weights are depending on model type:
• Single or Double Block Gate Valves• Size of connections, 3-1/16”, 4-1/16” etc.• Offshore or onshore transport Skid• Hunting also has compact models with low footprint
Ask Hunting for actual weights and dimensions.
Transport Size LxBxH cm
Weight, kg [lbm]
Certifications
Design Type Approval Type Approval Type Approval DVR
Manufacturing Declaration of Conformity Declaration of Conformity Declaration of Conformity Declaration of Conformity
Documentation Quality File Quality File Quality File Quality File
Applicable Codes
PED 97/23/EC PED 97/23/EC PED 97/23/EC PED 97/23/EC
ASME B31.3 ASME B31.3 ASME B31.3 ASME B31.3
API 6A API 6A API 6A API 6A
NACE MR 01-75(ISO 15156-1,-2)
NACE MR 01-75(ISO 15156-1,-2)
NACE MR 01-75 (ISO 15156-1,-2)
NACE MR 01-75 (ISO 15156-1,-2)
Optional with DNV 2.7-1 Optional with DNV 2.7-1 Optional with DNV 2.7-1 Optional with DNV 2.7-1
42
Choke Manifold
(1) Flow capacity is dependant on many factors. Please contact Hunting for advice.
(2) Connections cross-overs can be added as per customer requirements.
WCM
T EC H N I C A L I N F O R M AT I O N
P R O D U C T CO D E
N OT E S
Model WPC 5-1/8” 5K WPC 3-1/16” 10K WPC 4-1/16” 10K
Service H2S H2S H2S
Fluid Class DD DD DD
Working Pressure psi [bar] 5,000 [345] 10,000 [690] 10,000 [690]
Working Temperature °C [°F] -29 [0] up to 180 [350] -29 [0] up to 180 [350] -29 [0] up to 180 [350]
Filter Sizes [mu] As per customer requirement As per customer requirement As per customer requirement
Flow Capacity(1)
Gas, Mmscf [m³ / day] 50 [1.500.000] 50 [1.500.000] 100 [3.000.000]
Oil, bbls /day 15,000 5000 10,000
Standard Connections(2)
Gas / Oil Inlet API Flange 5-1/8” 5K API Flange 3-1/16” 10K API Flange 4-1/16” 15K
Gas / Oil Outlet API Flange 5-1/8” 5K API Flange 3-1/16” 10K API Flange 4-1/16” 15K
Drain API Flange 2-1/16” 5K API Flange 2-1/16” 5K API Flange 2-1/16” 5K
Operational Footprint LxB cm400 x 200 Sizes can be customized
400 x 200 Sizes can be customized
526 x 200 Sizes can be customized
Transport Size LxBxH cm400 x 200 x 150 Sizes can be customized
400 x 200 x 150 Sizes can be customized
526 x 200 x 150 Sizes can be customized
Weight, kg [lbm] 5000 [11,023] 6000 [13,227] 7000 [15,432]
Certifications
Design DVR DVR DVR
Manufacturing Declaration of Conformity Declaration of Conformity Declaration of Conformity
Documentation Quality File Quality File Quality File
Applicable Codes
PED 97/23/EC PED 97/23/EC PED 97/23/EC
ASME B31.3 ASME B31.3 ASME B31.3
API 6A API 6A API 6A
NACE MR 01-75 (ISO 15156-1,-2) NACE MR 01-75 (ISO 15156-1,-2) NACE MR 01-75 (ISO 15156-1,-2)
Optional DNV 2.7-1 Optional DNV 2.7-1 Optional DNV 2.7-1
43
(1) Flow capacity is dependant on many factors. Please contact Hunting for advice.
(2) Connections cross-overs can be added as per customer requirements.
N OT E S
Wellhead Plug Catcher
WPC
T EC H N I C A L I N F O R M AT I O N
P R O D U C T CO D E
Model Hunting SHE-S 5K Hunting SHE-S 10K 3” bore Hunting SHE-S 10K 4” bore Hunting SHE-S 15K
Service H2S H2S H2S H2S
Fluid Class DD DD DD DD
Coil 4” XXS 4” XXS 5” XXS 5”x3”
Working Pressure, psi [bar]
Coil 5,000 [345] 10,000 [690] 10,000 [690] 15,000 [1035]
Steam Vessel 150 [10,3] 150 [10,3] 150 [10,3] 150 [10,3]
Working Temperature - °C [°F] -20 [0] up to 180 [350] -20 [0] up to 180 [350] -20 [0] up to 180 [350] -20 [0] up to 180 [350]
Heating Capacity(1) - MMBtu/h 4,2 4,2 4,2 4,2
Standard Connections(2)
Gas / Oil Inlet API Flange 3-1/8” 5K API Flange 3-1/16” 10K API Flange 4-1/16” 10K API Flange 3-1/16” 15K
Gas / Oil Outlet API Flange 3-1/8” 5K API Flange 3-1/16” 10K API Flange 4-1/16” 10K API Flange 3-1/16” 15K
Steam Inlet Union 2” Fig.206 Union 2” Fig.206 Union 2” Fig.206 Union 2” Fig.206
Steam oulet Union 2” Fig.206 Union 2” Fig.206 Union 2” Fig.206 Union 2” Fig.206
Operational Footprint LxB cm 719 x 198 719 x 198 719 x 198 790 x 220
Transport Size LxBxH cm 719 x 198 x 259 cm 719 x 198 x 259 719 x 198 x 259 790 x 220 x 263
Weight, kg [lbm] 12.000 [26,445] 12.000 [26,445] 12.000 [26,445] 16.000 [35,273]
Certifications
Design Type Approval Type Approval Type Approval Type Approval
Manufacturing Declaration of Conformity Declaration of Conformity Declaration of Conformity Declaration of Conformity
Documentation Quality File Quality File Quality File Quality File
Applicable Codes
PED 97/23/EC PED 97/23/EC PED 97/23/EC PED 97/23/EC
ASME B31.3 ASME B31.3 ASME B31.3 ASME B31.3
ASME VIII div.1 ASME VIII div.1 ASME VIII div.1 ASME VIII div.1
API 6A API 6A API 6A API 6A
NACE MR 01-75 (ISO 15156-1,-2)
NACE MR 01-75 (ISO 15156-1,-2)
NACE MR 01-75 (ISO 15156-1,-2)
NACE MR 01-75 (ISO 15156-1,-2)
DNV 2.7-1 DNV 2.7-1 DNV 2.7-1 DNV 2.7-1
Heat Exchanger (Standard Type)
(1) Heating capacity is dependant on many factors. Please contact Hunting for advice.
(2) Connections cross-overs can be added as per customer requirements.
SHE-S
T EC H N I C A L I N F O R M AT I O N
P R O D U C T CO D E
N OT E S
44
Model Hunting SHE-C 5K Hunting SHE-C 10K 3” bore Hunting SHE-S 10K 4” bore Hunting SHE-S 15K
Service H2S H2S H2S H2S
Fluid Class DD DD DD DD
Coil 4” XXS 4” XXS 5” XXS 5”x3”
Working Pressure, psi [bar]
Coil 5,000 [345] 10,000 [690] 10,000 [690] 15,000 [1035]
Steam Vessel 150 [10.3] or 230 [15.8] 150 [10.3] or 230 [15.8] 150 [10,3] 150 [10,3]
Working Temperature - °C [°F] -20 [0] up to 180 [350] -20 [0] up to 180 [350] -20 [0] up to 180 [350] -20 [0] up to 180 [350]
Heating Capacity(1) - MMBtu/h 4,2 4,2 4,2 4,2
Standard Connections(2)
Gas / Oil Inlet API Flange 3-1/8” 5K API Flange 3-1/16” 10K API Flange 4-1/16” 10K API Flange 3-1/16” 15K
Gas / Oil Outlet API Flange 3-1/8” 5K API Flange 3-1/16” 10K API Flange 4-1/16” 10K API Flange 3-1/16” 15K
Steam Inlet Union 2” Fig.206 Union 2” Fig.206 Union 2” Fig.206 Union 2” Fig.206
Steam oulet Union 2” Fig.206 Union 2” Fig.206 Union 2” Fig.206 Union 2” Fig.206
Operational Footprint LxB cm 6055 x 244 6055 x 244 719 x 198 790 x 220
Transport Size LxBxH cm6055 x 244 x 259 20 ft Container Skid
6055 x 244 x 259 20 ft Container Skid
719 x 198 x 259 790 x 220 x 263
Weight, kg [lbm] 13.000 [26,660] 13.000 [26,660] 12.000 [26,445] 16.000 [35,273]
Certifications
Design Type Approval Type Approval Type Approval Type Approval
Manufacturing Declaration of Conformity Declaration of Conformity Declaration of Conformity Declaration of Conformity
Documentation Quality File Quality File Quality File Quality File
Applicable Codes
PED 97/23/EC PED 97/23/EC PED 97/23/EC PED 97/23/EC
ASME B31.3 ASME B31.3 ASME B31.3 ASME B31.3
ASME VIII div.1 ASME VIII div.1 ASME VIII div.1 ASME VIII div.1
API 6A API 6A API 6A API 6A
NACE MR 01-75 (ISO 15156-1,-2)
NACE MR 01-75 (ISO 15156-1,-2)
NACE MR 01-75 (ISO 15156-1,-2)
NACE MR 01-75 (ISO 15156-1,-2)
DNV 2.7-1 DNV 2.7-1 DNV 2.7-1 DNV 2.7-1
(1) Heating capacity is dependant on many factors. Please contact Hunting for advice.
(2) Connections cross-overs can be added as per customer requirements.
N OT E S
Heat Exchanger (Container Type)
SHE-C
T EC H N I C A L I N F O R M AT I O N
P R O D U C T CO D E
45
Model Hunting VST
Service H2S
Fluid Class DD
Working Pressure psi [bar]
Piping psi [bar] 150 [10.3]
Vessel psi [bar] 150 [10.3]
Working Temperature °C [°F] -29 [-20] up to 121 [250]
Storage Capacity m³ 16
Standard Connections(1)
Gas / Oil Inlet Union 3” Fig.602
Oil Outlet Union 3” Fig.602
Gas Outlet Union 4” Fig.602
Drain Union 3” Fig.602
Safety Relief Union 4” Fig.602
Optional Connections(1)
Steam Inlet Union 2” Fig.206
Steam oulet Union 2” Fig.206
Operational Footprint, LxB cm 282 x 240
Transport Size, LxBxH cm 7440 x 240 x 282
Weight, kg [lbm] 16.000 [26,660]
Certifications
Design Type Approval
Manufacturing Declaration of Conformity
Documentation Quality File
Applicable Codes
PED 97/23/EC
ASME B31.3
ASME VIII div.1
API 6A
NACE MR 01-75 (ISO 15156-1,-2)
DNV 2.7-1
DNV-OS-E101
46
Vertical Surge Tank
(1) Connections can be changed as per customer requirements.