Page 1 ©Hesse Mechatronics 08/2013 Wedge Bonding Medical Devices Shaving Microns to Achieve your Thinness Goals Joe Bubel, President Hesse Mechatronics Inc. 225 Hammond Ave, Fremont, CA 94539 P:484-665-0219, F:484-231-3232 Email: [email protected] Lee Levine Distinguished Member of the Technical Staff Hesse Mechatronics Inc 8009 George Road, New Tripoli, PA 18066 P:610-248-2002, F:484-217-2001, Email: [email protected]

Wedge Bonding Medical Devices - MEPTEC.ORGmeptec.org/Resources/13-Hesse Mechatronics.pdf · ©Hesse Mechatronics 08/2013 Page 1 Wedge Bonding Medical Devices Shaving Microns to Achieve

Embed Size (px)

Citation preview

Page 1: Wedge Bonding Medical Devices - MEPTEC.ORGmeptec.org/Resources/13-Hesse Mechatronics.pdf · ©Hesse Mechatronics 08/2013 Page 1 Wedge Bonding Medical Devices Shaving Microns to Achieve

Page 1©Hesse Mechatronics 08/2013

Wedge Bonding Medical DevicesShaving Microns to Achieve your Thinness Goals

Joe Bubel, PresidentHesse Mechatronics Inc.

225 Hammond Ave,Fremont, CA 94539

P:484-665-0219, F:484-231-3232Email: [email protected]

Lee LevineDistinguished Member of the Technical Staff

Hesse Mechatronics Inc 8009 George Road,

New Tripoli, PA 18066P:610-248-2002, F:484-217-2001,

Email: [email protected]

Page 2: Wedge Bonding Medical Devices - MEPTEC.ORGmeptec.org/Resources/13-Hesse Mechatronics.pdf · ©Hesse Mechatronics 08/2013 Page 1 Wedge Bonding Medical Devices Shaving Microns to Achieve

Page 2©Hesse Mechatronics 08/2013

• Reliability• Size, miniaturization• Unusual materials• Loop shape• Inductance• Ribbon bonding• Cost• Only Wire Bonding is Flexible enough

to handle all of these requirements

Medical Device Requirements

Page 3: Wedge Bonding Medical Devices - MEPTEC.ORGmeptec.org/Resources/13-Hesse Mechatronics.pdf · ©Hesse Mechatronics 08/2013 Page 1 Wedge Bonding Medical Devices Shaving Microns to Achieve

Page 3©Hesse Mechatronics 08/2013

How much Au is in 1 wire bond?

• Assumptions– 150 mils (3.75mm) wire length– 1 mil (25µm) wire diameter– Gold Price $1400/tr-oz

• Answer– $0.00168

• Understand the issues before considering Copper

Page 4: Wedge Bonding Medical Devices - MEPTEC.ORGmeptec.org/Resources/13-Hesse Mechatronics.pdf · ©Hesse Mechatronics 08/2013 Page 1 Wedge Bonding Medical Devices Shaving Microns to Achieve

Page 4©Hesse Mechatronics 08/2013

• The Homologous Temperature is the % of the melting point (MP) in 0K

Ultrasonics allows “easier” deformation by unlocking dislocation movement mechanisms

Calculation660C + 273=933 K18C (RT)+273=291K291/933= 31%

MP[C] MP[K] Room Temp 1500CAl 660 933 31 45Au 1064 1337 22 32Cu 1084 1357 22 31

AuSn(Eutectic) 280 553 53 77PbSn(Eutectic) 183 456 64 93

% Homologous Temp

Wire Bonding is a Welding Process

Page 5: Wedge Bonding Medical Devices - MEPTEC.ORGmeptec.org/Resources/13-Hesse Mechatronics.pdf · ©Hesse Mechatronics 08/2013 Page 1 Wedge Bonding Medical Devices Shaving Microns to Achieve

Page 5©Hesse Mechatronics 08/2013

0

50

100

150

200

250

Def

orm

atio

n %

Std 60Khz Ball Bond

Latest 60Khz Wedge Bond

Std 60kHz Wedge Bond

Fine Pitch Ball Bond

Fine Pitch Wedge Bond

Deformation %= (Bond Width-WireDia)/ Wire Dia *100%

Finer Pitch with Larger Diameter Wire (Higher current carrying Capacity)

Page 6: Wedge Bonding Medical Devices - MEPTEC.ORGmeptec.org/Resources/13-Hesse Mechatronics.pdf · ©Hesse Mechatronics 08/2013 Page 1 Wedge Bonding Medical Devices Shaving Microns to Achieve

Page 6©Hesse Mechatronics 08/2013

35µm Pitch 38µm Pitch 40µm Pitch

20µm Wire

Page 7: Wedge Bonding Medical Devices - MEPTEC.ORGmeptec.org/Resources/13-Hesse Mechatronics.pdf · ©Hesse Mechatronics 08/2013 Page 1 Wedge Bonding Medical Devices Shaving Microns to Achieve

Page 7©Hesse Mechatronics 08/2013

Decreasing Wire Diameter

Wire Length [mm]

Copper Conductivity 25% > Au

0.00

0.25

0.50

0.75

1.00

1.25

1.50

1.75

2.00

0 1 2 3 4 5

DC Ope

ratin

g Cu

rren

t [A] 

8µm13µm15µm20µm25µm

Wedge bonding enables use of larger wire than ball bonding for the same pitch

Page 8: Wedge Bonding Medical Devices - MEPTEC.ORGmeptec.org/Resources/13-Hesse Mechatronics.pdf · ©Hesse Mechatronics 08/2013 Page 1 Wedge Bonding Medical Devices Shaving Microns to Achieve

Page 8©Hesse Mechatronics 08/2013

• Lowest loop heights• Realtime bond quality measures• Deepest Access (18mm)• Placement Repeatability 1µm @ 3σ• Bondhead travel of 12”x16”• Stacked Die• Ribbon & round wire bonding on one

platform • Conductivity• Multiple wire materials (Al, Au, Cu, Pt)

WEDGE BOND FLEXIBILITY

Page 9: Wedge Bonding Medical Devices - MEPTEC.ORGmeptec.org/Resources/13-Hesse Mechatronics.pdf · ©Hesse Mechatronics 08/2013 Page 1 Wedge Bonding Medical Devices Shaving Microns to Achieve

Page 9©Hesse Mechatronics 08/2013

S-Shaped Bonding Allows Radial Fan-out

Page 10: Wedge Bonding Medical Devices - MEPTEC.ORGmeptec.org/Resources/13-Hesse Mechatronics.pdf · ©Hesse Mechatronics 08/2013 Page 1 Wedge Bonding Medical Devices Shaving Microns to Achieve

Page 10©Hesse Mechatronics 08/2013

Ribbon Bonds

• Gold and aluminum

• Deep access bondhead

• 6 x 35 µm to 25 x 250 µm

• Ribbon stitch bonds

Page 11: Wedge Bonding Medical Devices - MEPTEC.ORGmeptec.org/Resources/13-Hesse Mechatronics.pdf · ©Hesse Mechatronics 08/2013 Page 1 Wedge Bonding Medical Devices Shaving Microns to Achieve

Page 11©Hesse Mechatronics 08/2013

0

1

2

3

4

5

6

7

8

0 2 4 6 8 10

Equi

vale

nt R

ound

Wire

Dia

met

er [m

il]

Ribbon Width [mil]

Ribbon Thickness = .5 mil

Ribbon Thickness = 1mil

Diameter of Round Wire with Equivalent Skin Effect

Ribbon Conductivity

• At high frequency all conduction is through the wire “skin” (outer 0.5µm)

• GaAs MMIcs are ribbon bonded

Page 12: Wedge Bonding Medical Devices - MEPTEC.ORGmeptec.org/Resources/13-Hesse Mechatronics.pdf · ©Hesse Mechatronics 08/2013 Page 1 Wedge Bonding Medical Devices Shaving Microns to Achieve

Page 12©Hesse Mechatronics 08/2013

Process Integrated

Quality Control

Simply put, PiQC™ is the truest measure of bond quality available today.

Page 13: Wedge Bonding Medical Devices - MEPTEC.ORGmeptec.org/Resources/13-Hesse Mechatronics.pdf · ©Hesse Mechatronics 08/2013 Page 1 Wedge Bonding Medical Devices Shaving Microns to Achieve

Page 13©Hesse Mechatronics 08/2013

Sensor

• Current• Voltage• Frequency Monitoring all these

signals provides an exhaustive insight into the bond process.

The wedge tip oscillation has significant influence on bond quality and is influenced by the conditions of the wire & bond interface (frictionfeedback).

Digital Ultrasonic Generator

Actuator(patented)

• Wire Deformation

• Mechanical Oscillations• Friction

PiQC™-Signals

What is PiQC™?

Page 14: Wedge Bonding Medical Devices - MEPTEC.ORGmeptec.org/Resources/13-Hesse Mechatronics.pdf · ©Hesse Mechatronics 08/2013 Page 1 Wedge Bonding Medical Devices Shaving Microns to Achieve

Page 14©Hesse Mechatronics 08/2013

PiQC™ Production Views

• Deformation• Current• Radar Chart• Histogram• Q-Development

(200 values)• Individual user

interface possible

• Data storage and tracability

Page 15: Wedge Bonding Medical Devices - MEPTEC.ORGmeptec.org/Resources/13-Hesse Mechatronics.pdf · ©Hesse Mechatronics 08/2013 Page 1 Wedge Bonding Medical Devices Shaving Microns to Achieve

Page 15©Hesse Mechatronics 08/2013

Wire No.

Frequency [%]

Friction [%]

Ultrasonic [%]

Wedge [%]

Wire[%]

Quality Index[%]

1 100 100 100 100 100 100

PiQC exclusive Signals

PiQC: Optimized Source Bond

Page 16: Wedge Bonding Medical Devices - MEPTEC.ORGmeptec.org/Resources/13-Hesse Mechatronics.pdf · ©Hesse Mechatronics 08/2013 Page 1 Wedge Bonding Medical Devices Shaving Microns to Achieve

Page 16©Hesse Mechatronics 08/2013

BondOn pad

Frequency [%]

Friction [%]

Ultrasonic [%]

Wedge [%]

Wire[%]

QualityIndex [%]

75% 99 100 100 100 100 9950% 58 99 100 51 100 2925% 37 23 21 24 49 0

PiQC exclusive Signals

PiQC: Misplaced Bonds

Page 17: Wedge Bonding Medical Devices - MEPTEC.ORGmeptec.org/Resources/13-Hesse Mechatronics.pdf · ©Hesse Mechatronics 08/2013 Page 1 Wedge Bonding Medical Devices Shaving Microns to Achieve

Page 17©Hesse Mechatronics 08/2013

Bond on Pad

Frequency [%]

Friction [%]

Ultrasonic [%]

Wedge [%]

Wire[%]

QualityIndex [%]

100% 100 100 100 100 100 10075% 100 89 97 89 99 7650% 100 94 99 68 99 63

PiQC exclusive Signals

PiQC: Displaced Destination Bonds

Page 18: Wedge Bonding Medical Devices - MEPTEC.ORGmeptec.org/Resources/13-Hesse Mechatronics.pdf · ©Hesse Mechatronics 08/2013 Page 1 Wedge Bonding Medical Devices Shaving Microns to Achieve

Page 18©Hesse Mechatronics 08/2013

Wire No.

Frequency [%]

Friction [%]

Ultrasonic [%]

Wedge [%]

Wire[%]

QualityIndex [%]

1 15 38 14 4 66 0

PiQC exclusive Signals

PiQC: Particle on Bond Pad

Page 19: Wedge Bonding Medical Devices - MEPTEC.ORGmeptec.org/Resources/13-Hesse Mechatronics.pdf · ©Hesse Mechatronics 08/2013 Page 1 Wedge Bonding Medical Devices Shaving Microns to Achieve

Page 19©Hesse Mechatronics 08/2013

Wire No.

Frequency [%]

Friction [%]

Ultrasonic [%]

Wedge [%]

Wire[%]

QualityIndex [%]

1 62 100 100 95 100 592 39 92 72 78 96 19

PiQC exclusive Signals

PiQC: Scratch on Bond Pad

Page 20: Wedge Bonding Medical Devices - MEPTEC.ORGmeptec.org/Resources/13-Hesse Mechatronics.pdf · ©Hesse Mechatronics 08/2013 Page 1 Wedge Bonding Medical Devices Shaving Microns to Achieve

Page 20©Hesse Mechatronics 08/2013

Wire No.

Frequency [%]

Friction [%]

Ultrasonic [%]

Wedge [%]

Wire[%]

QualityIndex [%]

1 98 100 100 96 81 762 95 100 91 89 88 67

PiQC exclusive Signals

PiQC: Short Tail + Big Deformation

Page 21: Wedge Bonding Medical Devices - MEPTEC.ORGmeptec.org/Resources/13-Hesse Mechatronics.pdf · ©Hesse Mechatronics 08/2013 Page 1 Wedge Bonding Medical Devices Shaving Microns to Achieve

Page 21©Hesse Mechatronics 08/2013

For additional information please contact:

Joseph S. BubelPresident

Hesse Mechatronics, Inc.(484) 665-0219

[email protected]

Lee LevineDistinguished Memberof the Technical Staff

Wedge Bonding Expert(610) 248-2002

[email protected]

Register at WireBondDemo.com for wire bonding demonstration videos and updates.