WCS_CAPACITY

Embed Size (px)

Citation preview

  • 8/13/2019 WCS_CAPACITY

    1/2

    Alcatel-Lucent 5060 Wireless Call ServerR E L E A S E # W 5 .1

    The Alcatel-Lucent 5060 Wireless Call Server (WCS) provides the call-control and signaling functionality that

    is central to the Alcatel-Lucent distributed-switching solution for mobile networks. Designed specifically for

    Third-Generation Partnership Project (3GPP) R4/R5/R6-compliant architectures, the Alcatel-Lucent 5060 WCSsignificantly improves network capacity, simplicity and operational efficiency.

    With its unique approach to building

    a massively scalable call-processing

    system, the carrier-grade, eld-proven

    Alcatel-Lucent 5060 WCS architecture

    supports an industry-leading capacity

    per footprint density ratio and can

    directly support up to 128 media

    gateways (MGWs). Available for

    deployment in todays Second Gen-

    eration and Third-Generation mobile

    networks (2G/2.5G/3G), the Alcatel-

    Lucent 5060 WCS supports evolution

    to the all-IP network, IP Multimedia

    Subsystem (IMS) as a Media Gateway

    Control Function (MGCF) and to Long

    Term Evolution (LTE).

    Built on proven Alcatel-Lucentexperience in NGN platformevolution

    Together with the Alcatel-Lucent

    7549 Media Gateway and integrated

    Wireless Element Manager (WEM),

    the Alcatel-Lucent 5060 WCS is at the

    center of the Alcatel-Lucent Mobile

    Next Generation Network (NGN)

    solution. Built on the second-generation

    of the Alcatel-Lucent Advanced Tele-

    communications Computing Architecture

    (ATCA) the selected technology for

    all Alcatel-Lucent common call- and

    session-control platforms the ATCA

    High Capacity (HC) Alcatel-Lucent

    5060 WCS delivers dramatic capacity

    improvements and cost savings com-

    pared to the previous generation of

    ATCA platforms.

    Features

    Fully redundant architecture

    Hardware/software fault tolerance

    Overload controls

    Automatic self-recovery

    Support for up to 128 MGWs

    Mobile Switching Center (MSC)

    pooling and geographical

    redundancy

    High scalability

    Support for up to 10 million

    subscribers on a single cabinet

    Reduced power and cooling

    requirements

  • 8/13/2019 WCS_CAPACITY

    2/2

    www.alcatel-lucent.com Alcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logoare trademarks of Alcatel-Lucent. All other trademarks are the property of their respective owners.The information presented is subject to change without notice. Alcatel-Lucent assumes no responsibilityfor inaccuracies contained herein. Copyright 2010 Alcatel-Lucent. All rights reserved.CPG0591101202 (12)

    Optimized IP with internal Ethernet

    switch and IP interfaces

    Integrated WEM

    Simplied conguration, fault

    and performance management of

    the Alcatel-Lucent 5060 WCS, all

    subtending MGWs and MSC pools

    Congures as any combination of:

    Visited MSC (VMSC)

    Gateway MSC (GMSC)

    MGCF

    Mobile NGN proactive monitoring

    and analysis capabilities

    Benefits

    Carrier-grade 99.999-percent

    availability and reliability

    High network resiliency

    Deployment exibility

    Reduced real-estate, power, cooling,

    operations and maintenance costs

    Rapid detection, isolation and

    alerting of network issues

    On mobile NGN

    Across the whole network

    Customized reports based on

    intelligence extracted from the

    network

    Service assurance

    Market analysis

    Capacity trending

    Future-ready investment with

    evolution to the all-IP network,

    IMS and LTE

    Technical specifications

    Capacity

    Scalable from 50,000 to10 million subscribers

    Protocols

    BSSAP, RANAP, Gs

    SS7 (ANSI, ITU) ISUP (andnational variants) and SIGTRAN

    INAP, GSM MAP and CAP

    SIP, SIP-I and BICC

    H.248, EGCP

    GTP-C, GTP-U (Gn), IPSec

    Wireless element management

    Integrated OAM&P capabilitiesin the Alcatel-Lucent 5060 WCSand MGWs

    SNMPv2 interface

    CORBA interface

    Java-based GUI

    Remote access

    CLI

    Reliability

    System down time: 2.85 min/year

    System availability:99.99945 percent

    Redundancy

    System-level geographicredundancy: 1:1, N:1

    Module-level redundancy:

    SAM 1+1 active/standby

    CCM N+N active/standby

    groups SIM+DDM N+1 load sharing

    IPM 1+1 active/standby

    Physical dimensions (two-shelfrack, form factor with doors)

    Height: 2000 mm (79 in.)

    Width: 600 mm (24 in.)

    Depth: 800 mm (32 in.)

    Weight: 320 kg to 360 kg(706 lb to 794 lb)

    Electrical characteristics(two-shelf rack)

    Power inputs: four -48-V DC feeds Input current: four 110-A feeds

    Input voltage: -42.0-V DC to-56.7-V DC

    Typical power consumption:3052 W

    Regulatory compliance

    Environment

    Operating temperature: -5Cto +45C (23F to 113F)

    Non-operating temperature(72 consecutive hours): -40Cto +70C (-40F to +158F)

    Operating relative humidity:5% to 90%

    Non-operating relative humidity:90% to 95% for 96 hours at40C (104F)

    Heat dissipation: 1259 W/m

    (117 W/ft)

    Altitude: 60 m (197 ft) belowsea level to 1800 m (5906 ft) at-5C to +50C (23F to 122F)

    Earthquake: Zone 4

    Acoustic noise: 60 dBA

    Board-level ESD: 8 kV and 15 kV

    RoHS 2002/95/EC (RoHS 5/6)

    WEEE 2002/96/EC

    ECMA Technical Report TR/70

    Electromagnetic

    compatibility (EMC)

    United States

    FCC Part 15, Subpart B

    Bellcore/Telcordia GR-1089-CORE

    IEC 61000-94

    Europe

    EN 300-386-2

    EN 55022

    EN 61000- 4-2, Level 4

    EN 61000- 4-3, Level 2

    EN 61000-4-4, Level 2

    EN 61000- 4-5, Level 2

    EN 61000-4-6, Level 2

    EN 61000-4-11 ETS 300 386-1

    ETS 300 126

    Austra lia

    AS/NZS 3548

    International

    CISPR 22, Class ACanada

    ICES-003

    Taiwan

    CNS 13438

    Product safety

    North America

    CSA 22.2 No. 950-00, Third Edition(60950)

    UL 60950, Third Edition

    Bellcore/Telcordia GR-1089-CORE

    Europe

    EN 60950 with amendments

    A1/A2/A3International

    IEC 950 with amendmentsA1/A2/A3

    Bonding, grounding and

    power requirements

    North America

    Bellcore/Telcordia GR-1089-CORE

    Europe and international

    ETS 300 253

    ETS 300 132-1

    ETS 300 132-2