Alcatel-Lucent 5060 Wireless Call ServerR E L E A S E # W 5 .1
The Alcatel-Lucent 5060 Wireless Call Server (WCS) provides the call-control and signaling functionality that
is central to the Alcatel-Lucent distributed-switching solution for mobile networks. Designed specifically for
Third-Generation Partnership Project (3GPP) R4/R5/R6-compliant architectures, the Alcatel-Lucent 5060 WCSsignificantly improves network capacity, simplicity and operational efficiency.
With its unique approach to building
a massively scalable call-processing
system, the carrier-grade, eld-proven
Alcatel-Lucent 5060 WCS architecture
supports an industry-leading capacity
per footprint density ratio and can
directly support up to 128 media
gateways (MGWs). Available for
deployment in todays Second Gen-
eration and Third-Generation mobile
networks (2G/2.5G/3G), the Alcatel-
Lucent 5060 WCS supports evolution
to the all-IP network, IP Multimedia
Subsystem (IMS) as a Media Gateway
Control Function (MGCF) and to Long
Term Evolution (LTE).
Built on proven Alcatel-Lucentexperience in NGN platformevolution
Together with the Alcatel-Lucent
7549 Media Gateway and integrated
Wireless Element Manager (WEM),
the Alcatel-Lucent 5060 WCS is at the
center of the Alcatel-Lucent Mobile
Next Generation Network (NGN)
solution. Built on the second-generation
of the Alcatel-Lucent Advanced Tele-
communications Computing Architecture
(ATCA) the selected technology for
all Alcatel-Lucent common call- and
session-control platforms the ATCA
High Capacity (HC) Alcatel-Lucent
5060 WCS delivers dramatic capacity
improvements and cost savings com-
pared to the previous generation of
ATCA platforms.
Features
Fully redundant architecture
Hardware/software fault tolerance
Overload controls
Automatic self-recovery
Support for up to 128 MGWs
Mobile Switching Center (MSC)
pooling and geographical
redundancy
High scalability
Support for up to 10 million
subscribers on a single cabinet
Reduced power and cooling
requirements
8/13/2019 WCS_CAPACITY
2/2
www.alcatel-lucent.com Alcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logoare trademarks of Alcatel-Lucent. All other trademarks are the property of their respective owners.The information presented is subject to change without notice. Alcatel-Lucent assumes no responsibilityfor inaccuracies contained herein. Copyright 2010 Alcatel-Lucent. All rights reserved.CPG0591101202 (12)
Optimized IP with internal Ethernet
switch and IP interfaces
Integrated WEM
Simplied conguration, fault
and performance management of
the Alcatel-Lucent 5060 WCS, all
subtending MGWs and MSC pools
Congures as any combination of:
Visited MSC (VMSC)
Gateway MSC (GMSC)
MGCF
Mobile NGN proactive monitoring
and analysis capabilities
Benefits
Carrier-grade 99.999-percent
availability and reliability
High network resiliency
Deployment exibility
Reduced real-estate, power, cooling,
operations and maintenance costs
Rapid detection, isolation and
alerting of network issues
On mobile NGN
Across the whole network
Customized reports based on
intelligence extracted from the
network
Service assurance
Market analysis
Capacity trending
Future-ready investment with
evolution to the all-IP network,
IMS and LTE
Technical specifications
Capacity
Scalable from 50,000 to10 million subscribers
Protocols
BSSAP, RANAP, Gs
SS7 (ANSI, ITU) ISUP (andnational variants) and SIGTRAN
INAP, GSM MAP and CAP
SIP, SIP-I and BICC
H.248, EGCP
GTP-C, GTP-U (Gn), IPSec
Wireless element management
Integrated OAM&P capabilitiesin the Alcatel-Lucent 5060 WCSand MGWs
SNMPv2 interface
CORBA interface
Java-based GUI
Remote access
CLI
Reliability
System down time: 2.85 min/year
System availability:99.99945 percent
Redundancy
System-level geographicredundancy: 1:1, N:1
Module-level redundancy:
SAM 1+1 active/standby
CCM N+N active/standby
groups SIM+DDM N+1 load sharing
IPM 1+1 active/standby
Physical dimensions (two-shelfrack, form factor with doors)
Height: 2000 mm (79 in.)
Width: 600 mm (24 in.)
Depth: 800 mm (32 in.)
Weight: 320 kg to 360 kg(706 lb to 794 lb)
Electrical characteristics(two-shelf rack)
Power inputs: four -48-V DC feeds Input current: four 110-A feeds
Input voltage: -42.0-V DC to-56.7-V DC
Typical power consumption:3052 W
Regulatory compliance
Environment
Operating temperature: -5Cto +45C (23F to 113F)
Non-operating temperature(72 consecutive hours): -40Cto +70C (-40F to +158F)
Operating relative humidity:5% to 90%
Non-operating relative humidity:90% to 95% for 96 hours at40C (104F)
Heat dissipation: 1259 W/m
(117 W/ft)
Altitude: 60 m (197 ft) belowsea level to 1800 m (5906 ft) at-5C to +50C (23F to 122F)
Earthquake: Zone 4
Acoustic noise: 60 dBA
Board-level ESD: 8 kV and 15 kV
RoHS 2002/95/EC (RoHS 5/6)
WEEE 2002/96/EC
ECMA Technical Report TR/70
Electromagnetic
compatibility (EMC)
United States
FCC Part 15, Subpart B
Bellcore/Telcordia GR-1089-CORE
IEC 61000-94
Europe
EN 300-386-2
EN 55022
EN 61000- 4-2, Level 4
EN 61000- 4-3, Level 2
EN 61000-4-4, Level 2
EN 61000- 4-5, Level 2
EN 61000-4-6, Level 2
EN 61000-4-11 ETS 300 386-1
ETS 300 126
Austra lia
AS/NZS 3548
International
CISPR 22, Class ACanada
ICES-003
Taiwan
CNS 13438
Product safety
North America
CSA 22.2 No. 950-00, Third Edition(60950)
UL 60950, Third Edition
Bellcore/Telcordia GR-1089-CORE
Europe
EN 60950 with amendments
A1/A2/A3International
IEC 950 with amendmentsA1/A2/A3
Bonding, grounding and
power requirements
North America
Bellcore/Telcordia GR-1089-CORE
Europe and international
ETS 300 253
ETS 300 132-1
ETS 300 132-2