Prepared by Exit Design
Wayfinding and Signage ManualPart 1 of 2 Version 1.0 | 8/15/19
2LEHIGH UNIVERSITY | Wayfinding and Signage Manual
TABLE OF CONTENTS
Section 1—About the Sign System
Introduction 1.3
Wayfinding at Lehigh 1A
Glossary of Terms 1A.4
How to Use the Manual 1B
Graphic Standards 1C
Typography 1C.2Symbols 1C.3Arrows 1C.4Colors and Materials 1C.5
3LEHIGH UNIVERSITY | Wayfinding and Signage Manual
TABLE OF CONTENTS
Section 2—Sign System OverviewSign System Overview 2
Campus Gateways 2AGWY.1–Signature Gateway 2A.2 GWY.2–Secondary Gateway Horizontal 2A.5 GWY.3–Secondary Gateway Vertical 2A.8 GWY.4–Campus Identification 2A.11
Vehicular Wayfinding 2BCTB.1–Campus Trailblazer 2B.2 VDR.1–Vehicular Directional: Ground Mounted 2B.5 VDR.2–Vehicular Directional: Post and Panel (Small) 2B.9VDR.3–Vehicular Directional: Post and Panel (Large) 2B.12VRG.3–Street Name 2B.15
Building Identification 2CBID.1–Building Identification: Pedestrian 2C.2 BID.2–Building Identification: Vehicular 2C.5 BID.3–Building Identification: Wall Mounted Plaque 2C.8 BID.4–Building Identification: Dimensional Letters 2C.12 BID.5–Building Identification: Vinyl Letters 2C.14BID.6–Building Identification: Greek Housing 2C.17BID.7–Building Identification: Wall Mounted Address 2C.20BID.8–Building Identification: Wall Mounted No Smoking 2C.23
Parking 2DPBB.1–Garage Clearance Bang Bar 2D.2PID.1–Parking Identification: Large 2D.3 PID.2–Parking Identification: Small 2D.6PID.3–Parking Symbol: Building Mounted 2D.9PID.4–Parking Identification: Dimensional Letters 2C.15 PRG.1–Garage Entrance/Exit 2D.10 VRG.1–Parking Regulatory: Small 2D.11VRG.2–Parking Regulatory: Large 2D.13VRG.4–No Smoking Regulatory: Small 2D.16
Pedestrian 2EBUS.1–Shuttle Stop Monolith 2E.2GR.1–Stair Graphics 2E.5IHB.1MS–Information Hub: Multi-sided 2E.8 IHB.1MD–Information Hub: Multi-sided Digital 2E.11 IHB.2SS–Information Hub: Single-sided 2E.14IHB.2SD–Information Hub: Single-sided Digital 2E.17PDR.1–Pedestrian Directional 2E.20
Construction Details 2FDetails A/B 2F.2Details C/D 2F.3Detail C2 2F.4Details C3 2F.5Details C4 2F.6Details C5/C6 2F.7Detail E 2F.8Detail F 2F.9Detail G 2F.10Detail H 2F.11Details K1 2F.12Details K2 2F.13Detail L 2F.14Details M/N 2F.15Details Q1–Q4 2F.16
Installation Details 2GGrade Conditions 2G.2 Footing/Mounting Details/Q6 2G.5
Placement Guidelines 2H
Performance Specifications 2J
Section 3—Sign MaintenanceWayfinding Champion 3A
Existing Sign Removal & New Sign Implementation 3B
How to Maintain Your System 3C
Order Form 3D
Contacts 3E
This Page is Intentionally Left Blank
SECTION 1
About the Sign System
This Page is Intentionally Left Blank
1.3LEHIGH UNIVERSITY | Wayfinding and Signage Manual
INTRODUCTION
IntroductionLehigh University, located in Bethlehem, Pennsylvania, spans 1,600 acres across three campuses:
1. Packer 2. Mountaintop 3. Goodman
Lehigh University has recently announced its ambitious new “Path to Prominence" plan that will transform the physical campus landscape to support dramatic academic growth over the next ten years. A key component in improving the built environment and landscape design to achieve this plan is the creation of wayfinding and signage standards and an implementation strategy to establish a coherent, navigable, and consistent identity for Lehigh University. The Wayfinding and Signage program at Lehigh University is guided by the following vision and objectives:
VisionCreate a system of total support to help students, prospective students and families, faculty, staff, and the general public navigate the campus with ease. Support their journey with respect, empathy and joy.
ObjectivesCreate a visitor-centric experience.
Develop a wayfinding system that creates a coherent and navigable campus environment.
Elevate the Lehigh University brand in the environment.
Connect, leverage, and strengthen Lehigh University assets.
Engage stakeholders including the City of Bethlehem, Lower Saucon, Hellertown, and PennDOT to create a consistent wayfinding experience beyond Lehigh University borders.
Provide leadership in innovation and design.
Assist users in navigating the steep topography of the campus.
Apply sustainable concepts and principles to the system through the efficient use of natural and manufactured resources.
Create a sustainable, maintainable, and flexible system to respond to the continued campus growth.
Consider technology to enhance the system.
This Page is Intentionally Left Blank
SECTION 1A
Wayfinding at Lehigh
1A.2LEHIGH UNIVERSITY | Wayfinding and Signage Manual
Wayfinding At Lehigh UniversityWayfinding is a process of spatial orientation and decision-making along an individual’s path of travel to a destination. There are points along this journey when orientation is required to make a decision about which direction to proceed. Exterior signs provide the information necessary to guide students, visitors and staff to destinations, identify areas and provide safety information. A successful sign system assists people in finding their way, enhances the campus environment and complies with the Americans with Disabilities Act (ADA) and local regulations.
In 2017, Lehigh University assessed the manner in which it moves people between, around and through its campuses to develop a new wayfinding strategy. Lehigh University engaged Exit Design, a Philadelphia-based design firm, to evaluate its campus wayfinding, access and usability. Comprehensive signage audit, site observations, tours, fieldwork and work sessions with University stakeholders informed the design direction of the sign program.
The Experience Assessment audit provided a clear understanding of the current campus experience. Its findings were used to develop an overall Wayfinding Master Plan for a new campus experience to match the growth of the University and accommodate future changes.
The Wayfinding Master Plan identifies the top wayfinding challenges on campus and outlines the opportunities to address these challenges and enhance the overall user experience across all campuses. Recommendations include creating an overall language of wayfinding for the campuses, promoting pedestrian navigation of the campus, enhancing the connection between campuses and across the mountain, and enhancing the campus shuttle experience.
This comprehensive wayfinding and signage standards manual documents the approved design direction to address the needs identified in the Wayfinding Master Plan (8/1/18), and demonstrates constructability, maintenance, and guidelines for implementation.
The University’s visual identity system and image was translated to a new, aesthetically distinct, affordable and easily maintainable exterior sign standard system. The new standards outline guidelines for signage locations, keeping in mind that campus beautification efforts include minimizing the quantity of signage in the campus landscape. The new sign system promotes the Lehigh University commitment to standardization, yet provides the flexibility to respond to the variety of campus conditions.
For the ease of wayfinding and direction-giving, Lehigh University has been divided into four distinct regions as shown in the map to the right. Packer Campus, the largest of Lehigh’s three campuses, has been divided into two neighborhoods based upon their unique characteristics: the Packer neighborhood (reflecting the core of academic buildings) and Sayre Park neighborhood (representing the residential housing on the mountainside). The wayfinding system has been developed to infuse the environment with the Lehigh Identity, connect the three campuses, support the approach and departure to and from each campus, delineate the two Packer neighborhoods, organize and create clarity in the pedestrian and vehicular wayfinding, and establish information hubs at key public destinations.
Wayfinding Sign Program PolicyThe Lehigh University Wayfinding and Signage Manual provides specific guidelines and standards to the Lehigh University community for the implementation of the Lehigh sign system across all University campuses, buildings and environments. The Lehigh University Signage Manual has been developed by Campus Planning and Projects with extensive advice and consultation from faculty, staff and students.
The power of a strong visual identity and consistent wayfinding system can only be realized through consistent application over time. It is Lehigh University’s policy that the official wayfinding signage, as described in this manual, is the only sanctioned wayfinding and signage system across Lehigh University. No other signage may be used or created to represent Lehigh University as a whole or any part thereof.
SECTION 1A | WAYFINDING AT LEHIGH
1A.3LEHIGH UNIVERSITY | Wayfinding and Signage Manual
SECTION 1A | WAYFINDING AT LEHIGH
9/12/2017 Google Maps
https://www.google.com/maps/@40.5974098,-75.3746404,14z 1/1
Map data ©2017 Google United States 2000 ft
378
78
378
PACKER
SAYRE
MOUNTAINTOP
GOODMAN
GWY.1-G-5022
Sign TypeCampusLocation Number
1A.4LEHIGH UNIVERSITY | Wayfinding and Signage Manual
Glossary Of TermsDefinitions of key concepts and tools are provided in this section:
Wayfinding Methodology
Finding and harnessing the hidden logic of a place to create a simple, clear and easily communicated methodology for wayfinding is the first step in providing directions to a visitor. A wayfinding methodology creates a platform or language for the wayfinding and signage program. This manual provides a deeper understanding of how to implement and maintain the wayfinding and signage program.
Hierarchy
The logic of wayfinding is heavily based on developing and maintaining a hierarchy of information. This pre-determined hierarchy applies to terminology, direction-giving methodology and even the design features of a system, such as typography and color.
Terminology
Lehigh University has developed a consistent terminology, or language, that should be used in all wayfinding communication, i.e. print, web, signage and verbal direction-giving.
Copy list
The Copy List details signs specified for fabrication. It references a sign location number that corresponds to a sign location plan and includes the sign type, copy to appear on each sign, quantity, and installation notes.
Sign Location Plans
Sign Location Plans are site or floor plans that show locations of each sign specified for installation. Each sign location number shown on the site plan references the sign location number in the copy list.
Sign Location Numbering
A strategy for sign location numbering has been developed to ease the process of review and revisions. For example:
There should be no duplicating number sequences. Every location should have a unique location number.
Sign Type Numbering System
The “Sign Type Numbering System” is designed to assist in specifying each sign type. The numbers help organize the signs by function, layout and product category.
Sign System OverviewThe sign system overview section of this manual shows every sign type in the system, organized by sign type category. Each sign type category includes an introduction to its usage. For each sign type, a description of the sign and its function, the sign type number and overall size is provided as a quick reference.
Design Intent DrawingsEach sign type is dimensioned and detailed in the specification section of the manual. Every sign type has at least four pages (front and back) of fabrication and installation details. These pages are organized so that they can be removed from the manual, copied, and provided to a fabricator and/or installer based upon an individual project’s needs.
Strategy SectionThe strategy section of the manual is designed for use by the team that is planning, managing and programming a wayfinding system at Lehigh University. This section provides the detailed strategies that were used to design the wayfinding system, and should be included in each implementation of the system.
Brand UsageThe logo, terminology, fonts, colors and signature elements of the Lehigh University brand are strategically included in the messaging and design of the Wayfinding and Signage System. The Lehigh logo and signatures are integrated, where appropriate, into the signage system. The goal for all logo usage is to adhere to the standards in the Lehigh University Branding and Visual Identity Guide. Any brand application in the system that deviates from the identity manual has been reviewed and approved for signage usage only.
Typically, logos appear on signage at large permanent installations, such as campus arrival moments, but not at individual information or regulatory warning signs. Some typefaces, colors and layouts are not suitable for application on large-scale environmental graphics. Critical adjustments may need to be made to brand elements for inclusion on signage. For questions about brand usage, contact the Lehigh University Communications and Public Affairs office.
SECTION 1A | WAYFINDING AT LEHIGH
SECTION 1B
How to Use the Manual
1B.2LEHIGH UNIVERSITY | Wayfinding & Signage Manual
SECTION 1B | HOW TO USE THE MANUAL
How To Use The Manual The manual has been developed for the ongoing maintenance of the system that includes comprehensive information for the Exterior Signage program. The Wayfinding and Signage Manual consists of a vocabulary of pre-designed sign types that will effectively meet a broad range of sign function requirements. This manual documents the signage program and describes the entire sign family as a sign system, including descriptions of sign types and their functions.
The Wayfinding and Signage Manual facilitates the implementation of signs across campus as new buildings are constructed and areas of campus are renovated and as a catalog to order replacements for damaged or outdated parts or signs where the program has already been installed.
This document is intended to provide project managers and other interested parties with a detailed description of the primary operating characteristics of the Exterior Sign program at Lehigh University. The manual is divided into three parts:
Section 1–About The Sign System
This section provides an overview of objectives, policies and strategies that were developed and approved by the Lehigh University Signage Working Group.
Section 2–Sign System Overview
Each exterior sign is shown with a drawing that specifies typography, color, materials, construction and installation details, placement guidelines and performance specifications.
Section 3–Sign Maintenance
This section outlines the levels of implementation of the signage standards and the tools and processes for maintaining the Signage System.
Sign Type Number Header
The Header outlines the sign type number and description, available configurations and variation details including size, illumination and mounting options. Use the reference chart on the right side of the Header for how to read the number.
Guidelines
This paragraph includes details about the design, usage, and programming of this specific sign type.
Construction / Installation Detail Reference
Construction and Mounting Details are shared between multiple sign types in the Manual and are noted as section call outs. Sign types may reference multiple details located in the Construction and Installation Detail sections.
Construction Specifications
Portions of the sign elevation, indicated with a letter in a black box, key to the notes at the bottom of the page.
General Color and Material Specifications
Color or Material specifications are noted with a P (paint) and number or M (material) and number, and key to the Color and Materials page in the Graphic Standards Section.
Typography Specification
Typography specifications are noted with a T (type) and a number that key to the Typefaces page in the Graphic Standards Section.
1
1 5
7
2
2
3
3 4
4
5 6
6
7
Understanding the Layout
1B.3LEHIGH UNIVERSITY | Wayfinding & Signage Manual
SECTION 1B | HOW TO USE THE MANUAL
This Page is Intentionally Left Blank
SECTION 1C
Graphic Standards
1C.2LEHIGH UNIVERSITY | Wayfinding and Signage Manual
SECTION 1C | GRAPHIC STANDARDS
LETTER SPACING
Typeface 1
Inconsistant Letter Spacing
IMPORTANT: Individual spacing of each letter needs to be evaluated. See Examples Above. Kern all Copy so that each character is optically centered between the center of each of the surrounding characters.
Correct Letter Spacing
Typeface 2
Typeface 3
Typeface 4
Typeface 1
Typeface 2
Typeface 3
Typeface 4
Visitor Parki
Visitor Parki
Visitor Parki
Visitor Parki
Visitor Parki
Visitor Parkin
Visitor Parkin
Visitor Parkin
Visitor Parkin
Typeface 5 Typeface 5
Visitor Parki
ARROWS AND TEXT RELATIONSHIPS
Always measure from baseline to baseline.Please reference below.
COPY HEIGHT
When measuring copy height, measure only the height of theCapital letters to determine your overall copy height shown in illustration below as “X.” Some of the other letters have an extended height beyond the average height of the letters.
LINE SPACING
When measuring line spacing, always measure from the baseline of the top most text line to the baseline of the text line below shown as “X.”
Drown HallDrown Hall
BASE LINE
BASE LINE
DrownDrown BASE LINEX
FarringtonFarringtonSquareSquare
BASE LINE
BASE LINEX
X
Neutrif Studio Regular Neutrif Studio Medium
Neutrif Studio Semi-Bold
Neutrif Studio Extra Bold
Neutrif Studio Bold
ABCDEFGHIJKLMNOPQRSTUVWXYZabcdefghijklmnopqrstuvwxyz
ABCDEFGHIJKLMNOPQRSTUVWXYZabcdefghijklmnopqrstuvwxyz
ABCDEFGHIJKLMNOPQRSTUVWXYZabcdefghijklmnopqrstuvwxyz
ABCDEFGHIJKLMNOPQRSTUVWXYZabcdefghijklmnopqrstuvwxyz
ABCDEFGHIJKLMNOPQRSTUVWXYZabcdefghijklmnopqrstuvwxyz
T1
T3
T2
T5
T4
TYPOGRAPHY
1C.3LEHIGH UNIVERSITY | Wayfinding and Signage Manual
SYMBOLSSECTION 1C | GRAPHIC STANDARDS
No Smoking Accessibility Lehigh Logo Lehigh University Logo
Parking Symbol
Do Not Enter
PA-378 Symbol PA-412 SymbolI78 Symbol
goLehigh Logo
Bus Logo
Color / Material / Finish Name Specification (Color to Match) Type, Substrate Application Process
White MP07275 - White Christmas AluminumSurface Painted with UV Clear Coat
Lehigh Gold MP06960 - Sun Coast AluminumSurface Painted with UV Clear Coat
Dark Brown MP07458 - Cast Bronze AluminumSurface Painted with UV Clear Coat
Black Match PMS Black 6 C AluminumSurface Painted with UV Clear Coat
Red Match PMS Warm Red C AluminumSurface Painted with UV Clear Coat
Black Match PMS Black 6 C Aluminum Surface Printed
Green Match PMS 390 C Aluminum Surface Printed
Lehigh Brown Match PMS 1545 C Aluminum Surface Printed
Light Brown Match PMS 7501 C Aluminum Surface Printed
Blue Match PMS 2995 C Aluminum Surface Printed
Light Gray Match PMS 887 C Aluminum Surface Printed
Lehigh Gold Match MP06960 - Sun Coast Aluminum Surface Printed
Red Match PMS Warm Red C Aluminum Surface Printed
Reflective Black Vinyl3M Reflective Black 5100-085
Aluminum Surface Applied
Opaque Black Vinyl3M Scotchal Electrocut 7125 Matte Black 22
Aluminum Surface Applied
White Vinyl3M Scotchal ElectrocutMatte White 7725-20
Glass Second Surface Applied
Dark Gray Vinyl3M Scotchal Electrocut7125
Dark Gray 41
Aluminum Surface Applied
Gray Vinyl3M Scotchal Electrocut7125
Mid Gray 61
Aluminum Surface Applied
Lehigh BrownDigitally print to matchPMS 1545 C
Aluminum Surface Applied
Reflective Red Vinyl3M Reflective Ruby Red 5100-082
Aluminum Surface Applied
1C.4LEHIGH UNIVERSITY | Wayfinding and Signage Manual
Up Left Left Down Left Down RightUp Right Up Right
Arrows should follow this order when messages direct within campuses or neighborhoods.
The standard arrow order forthe Lehigh University system is: Up, Left, Right.
Listings on all directional signsshould follow this order.
Separate and organize messagesfor destinations within a campusversus trailblazing to campusesby name (Example 1).
Arrow hierarchy still applies within each group listing (Example 2).
Straight Up-left Straight-up Left Straight-up Right Straight Up-right
Up
Left
Campus trailblazing is always listed after campus/neighborhooddirectional messages
Messages within campus/neighborhoodare always listed first.
Right
Example 1
Example 2
MOUNTAINTOPCAMPUS
Alumni MemorialBuilding
Visitor Parking
PACKER
PACKER
Alumni Memorial Building
Farrington Square
Parking
ARROWSSECTION 1C | GRAPHIC STANDARDS
Color / Material / Finish Name Specification (Color to Match) Type, Substrate Application Process
White MP07275 - White Christmas AluminumSurface Painted with UV Clear Coat
Lehigh Gold MP06960 - Sun Coast AluminumSurface Painted with UV Clear Coat
Dark Brown MP07458 - Cast Bronze AluminumSurface Painted with UV Clear Coat
Black Match PMS Black 6 C AluminumSurface Painted with UV Clear Coat
Red Match PMS Warm Red C AluminumSurface Painted with UV Clear Coat
Black Match PMS Black 6 C Aluminum Surface Printed
Green Match PMS 390 C Aluminum Surface Printed
Lehigh Brown Match PMS 1545 C Aluminum Surface Printed
Light Brown Match PMS 7501 C Aluminum Surface Printed
Blue Match PMS 2995 C Aluminum Surface Printed
Light Gray Match PMS 887 C Aluminum Surface Printed
Lehigh Gold Match MP06960 - Sun Coast Aluminum Surface Printed
Red Match PMS Warm Red C Aluminum Surface Printed
Reflective Black Vinyl3M Reflective Black 5100-085
Aluminum Surface Applied
Opaque Black Vinyl3M Scotchal Electrocut 7125 Matte Black 22
Aluminum Surface Applied
White Vinyl3M Scotchal ElectrocutMatte White 7725-20
Glass Second Surface Applied
Dark Gray Vinyl3M Scotchal Electrocut7125
Dark Gray 41
Aluminum Surface Applied
Gray Vinyl3M Scotchal Electrocut7125
Mid Gray 61
Aluminum Surface Applied
Lehigh BrownDigitally print to matchPMS 1545 C
Aluminum Surface Applied
Reflective Red Vinyl3M Reflective Ruby Red 5100-082
Aluminum Surface Applied
P1
P2
P4
P5
D1
D2
D3
D4
D5
D6
D7
D8
V1
V2
V3
P3
M1
V4
M2
V5
V6
V7
1C.5LEHIGH UNIVERSITY | Wayfinding and Signage Manual
SECTION 1C | GRAPHIC STANDARDS COLORS
Bronze
Aluminum
Dark Oxidized Bronze with matte clear coat
Brushed Horizontal finishwith matte clear coat
Bronze
Aluminum
Bronze
Surface Applied
This Page is Intentionally Left Blank
SECTION 2
Sign System Overview
2.2LEHIGH UNIVERSITY | Wayfinding and Signage Manual
SECTION 2 | SIGN SYSTEM OVERVIEW
Campus Gateways
GWY.1 — Signature Gateway
The Signature Gateway is intended as a landmark element at the primary campus arrival points (Packer, Mountaintop, and Goodman). These should be located for maximum visibility on approach.
GWY.2 — Secondary Gateway Horizontal
Horizontal Secondary Gateways mark arrival to all campuses at primary and secondary entrance points. This horizontal orientation should be used when there is ample real estate to accommodate this sign type. The less urban environments should accept this orientation.
GWY.3 — Secondary Gateway Vertical
Vertical Secondary Gateways mark arrival to all campuses at primary and secondary entrance points. This vertical orientation should be used when there is limited real estate to accommodate this sign type. This sign type works well for tight urban environments.
GWY.4 — Campus Identification
Campus Identification is intended to identify a campus by name. They can be used in conjunction with a Signature Gateway to mark a primary campus arrival. They can also be used as a standalone element to identify a transition point between campuses.
2.3LEHIGH UNIVERSITY | Wayfinding and Signage Manual
SECTION 2 | SIGN SYSTEM OVERVIEW
GWY.1Signature Gateway
GWY.2Secondary Gateway Horizontal
GWY.3Secondary Gateway Vertical
GWY.4Campus Identification
GOODMAN CAMPUS
MO
UN
TAIN
TOP
CA
MP
US
PA
CK
ER C
AM
PU
S
2.4LEHIGH UNIVERSITY | Wayfinding and Signage Manual
SECTION 2 | SIGN SYSTEM OVERVIEW
Vehicular Wayfinding
CTB.1 — Campus Trailblazer
Campus Trailblazers should only be used along roadways connecting campuses. These signs are intended to mark the Lehigh Campus as well as connect drivers from one campus to another.
VDR.1 —Vehicular Directional: Ground Mounted
Ground Mounted Vehicular Directionals are the primary vehicular directionals to be used throughout campus. This sign type should be positioned to be on the same side of the roadway as the flow of traffic and are primarliy a single-sided sign. Double-sided messaging is only permissible when there are no other options and locating messaging adjacent to the flow of traffic is not possible.
VDR.2 —Vehicular Directional: Post and Panel (Small)
Post and Panel Vehicular Directionals are to be used when a smaller footprint is required or the ground mounted condition does not allow for the acceptable traffic sightlines. The use of this sign type should be limited to the Packer Campus and should be used to meet the needs of the urban conditions.
VDR.3 —Vehicular Directional: Post and Panel (Large)
Post and Panel Vehicular Directionals are to be used when a smaller footprint is required or the ground mounted condition does not allow for the acceptable traffic sightlines. The use of this sign type should be limited to the Packer Campus and should be used to meet the needs of the urban conditions. This larger panel will accommodate longer 3 arrow messages.
VRG.3 — Street Name
Street signs are to be used on Lehigh University owned streets to help define the campus edge.
2.5LEHIGH UNIVERSITY | Wayfinding and Signage Manual
SECTION 2 | SIGN SYSTEM OVERVIEW
PACKER
MOUNTAINTOPCAMPUS
Drown Hall
Visitor Parking
PACKER
MOUNTAINTOPCAMPUS
Drown Hall
Visitor Parking
MOUNTAINTOPCAMPUS
GOODMANCAMPUS
SAYRE PARK
UNIVERSITY DR
Zoellner Arts Center
Alumni Memorial Building
Visitor Parking
Farrington Square
PACKER
CTB.1Campus Trailblazer
VRG.3Street Name
VDR.1Vehicular Directional:Ground Mounted
VDR.2Vehicular Directional:Post and Panel (Small)
VDR.3Vehicular Directional:Post and Panel (Large)
2.6LEHIGH UNIVERSITY | Wayfinding and Signage Manual
SECTION 2 | SIGN SYSTEM OVERVIEW
Building Identification
BID.1 — Building Identification: Pedestrian
Pedestrian Building Identification signs are used to identify buildings along a pedestrian path. This sign type should be located along a pedestrian walkway, perpendicular to the path at the point of approach to the building. These signs are typically double-sided unless the second side of the sign is not visible.
BID.2 — Building Identification: Vehicular
Vehicular Building Identification signs are used to identify buildings along a roadway. This sign type should be located perpendicular to the roadway, at the point of entry to the building driveway or in front of the building. These signs are typically double-sided unless the second side of the sign is not visible.
BID.3 — Building Identification: Wall Mounted Plaque
Wall Mounted Building Identification signage should be positioned to the right of a primary building entrance. This sign type should be used to identify points of building access from this entrance, specific entrance name, and accessibility. If conflicts occur the sign can be located to the left of the doorway as an alternate location.
BID.4 — Building Identification: Dimensional Letters
Dimensional letters are used to identify the name of a building, and are situated either above or next to the main entrance or can be used at a higher elevation to increase a building's visibility from across campus. A building's donor name may be identified using this sign type.
BID.5 — Building Identification: Vinyl Messaging
Vinyl messaging is to be used on glass entries to identify the building and entrance along with any other important regulatory information.
BID.6 — Building Identification: Greek Housing
Greek Housing Identification signs are used to identify greek houses along a roadway. This sign type should be located perpendicular to the roadway, at the point of entry to the house driveway or in front of the house. These signs are typically double-sided unless the second side of the sign is not visible
BID.7 — Building Identification: Wall Mounted Address
Wall Mounted Address signage should be positioned to the right of a primary building entrance. This sign type should be used for Greek Housing address identification. If conflicts occur the sign can be located to the left of the doorway as an alternate location.
BID.8 — Building Identification: Wall Mounted No Smoking
Wall Mounted No Smoking signs should be positioned near building entrances when vinyl messages at the door entrance cannot be utilized. Place signs in areas where smoking could occur within 25ft of a building. Minimize sign clutter by placing signage 300ft apart if multiple signs are required.
2.7LEHIGH UNIVERSITY | Wayfinding and Signage Manual
SECTION 2 | SIGN SYSTEM OVERVIEW
61 University Dr.
For the Physical Sciences
ShermanFairchildCenter
Accessible Entrance on opposite side of building
Rauch BusinessCenter
61 University Dr.
Taylor GymMain Entrance
TaylorGym
Accessible Entrance on opposite side of building
TAYLOR GYM
107 Hill Dr.
House107
107 No Smokingwithin 25ftof Building
BID.1Building Identification:Pedestrian
BID.4 / PID.4Building Identification Dimensional Letters
BID.5Building Identification Vinyl Letters
BID.6Building Identification Greek Housing
BID.7Building Identification
Wall Mounted Address
BID.8Building Identification
Wall MountedNo Smoking
BID.3Building Identification Wall Mounted Plaque
BID.2Building Identification:Vehicular
2.8LEHIGH UNIVERSITY | Wayfinding and Signage Manual
SECTION 2 | SIGN SYSTEM OVERVIEW
Parking
PBB.1 — Garage Clearance Bang Bar
This sign is to be used to mark the garage clearance upon entry to the garage. The bottom of this sign should be mounted to match the garage clearance and positioned at each point of clearance change.
PID.1 — Parking Identification: Large
Large Parking Identification signs should be located at parking lot entrances. Messaging should include lot name and number, what buildings the lot serves, plus any and all parking restrictions and rules.
PID.2 — Parking Identification: Small
Small Parking Identification signs should be located at parking garage entrances. Messaging should include the garage name and number, plus any and all parking restrictions and rules.
PID.3 — Parking Symbol: Building Mounted
Building mounted parking identification to increase visibility of visitor parking garages. This sign should be placed on the garage facade to optimize visibilty on the garage approach.
PID.4 — Parking Identification: Dimensional Letters
Dimensional letters are used to identify the name of a parking garage. Dimensional letters are situated either above or next to the main entrance or can be used at a higher elevation to increase a building's visibility from across campus.
PRG.1 — Garage Entrance/Exit
This sign is to be used to mark the lanes of ingress and egress of the garage.
VRG.1— Parking Regulatory: Small
Small Parking Regulatory signs are intended to post notices about parking information including: reserved spaces, parking restrictions, limitations, etc.. These are to be located at the head of parking spaces or adjacent to curb parking.
VRG.2— Parking Regulatory: Large
Large Parking Regulatory signs are intended to post notices about parking information including: reserved spaces, parking restrictions, limitations, etc.. These are to be located at the head of parking spaces or adjacent to curb parking.
VRG.4— No Smoking Regulatory: Small
Small No Smoking Regulatory signs are intended to post notices about No Smoking restrictions around buildings.
2.9LEHIGH UNIVERSITY | Wayfinding and Signage Manual
SECTION 2 | SIGN SYSTEM OVERVIEW
Visitor Lot
Cundey Varsity House
Rauch Field House
G1
6am–10pmNo Overnight Parking
RESERVED
MedicalPermitParking
EXIT ONLY
MAX. CLEARANCE 9'-0"
ENTER HERE
PARKING GARAGE
S67
Taylor House
McClin c-Marshall House
Drinker House
PERMIT PARKING
Alumni BuildingParkingPavilion
G2
0–2 hrs $22–4 hrs $44–6 hrs $66+ hrs $8
No Overnight Parking
G2Garage Address
No Smokingwithin 25ftof Building
PID.1Parking IdentificationLarge
PID.2Parking Identification Small
PID.3Parking Symbol:Building Mounted
PID.4 / BID.4Parking Identification:Dimensional Letters
VRG.1Parking RegulatorySmall
VRG.4No Smoking RegulatorySmall
VRG.2Parking RegulatoryLarge
PRG.1Garage Entrance/Exit
PBB.1Garage ClearanceBang Bar
2.10LEHIGH UNIVERSITY | Wayfinding and Signage Manual
SECTION 2 | SIGN SYSTEM OVERVIEW
Pedestrian
BUS.1 — Shuttle Stop Monolith
Shuttle Stop Monolith placement is dictated by the stop locations. These signs should always be double-sided and positioned perpendicular to the stop and the roadway.
GR.1— Stair Graphics
Stair Graphics are intended to motivate and incentivize pedestrians to navigate the inclines of campus on foot. The messaging for these graphics should be developed in conjunction with the brand voice of the University.
IHB.1 — Information Hub: Multi-sided
Multi-sided Information Hubs are structures that provide University-wide orientation and information as well as campus specific orientation and information. This sign type is located at key gathering spots and/or public destinations.
IHB.2— Information Hub: Single-sided
Single-sided Information Hubs are structures that provide University-wide orientation and information as well as campus specific orientation and information. This sign type is located at key gathering spots and/or public destinations.
PDR.1 — Pedestrian Directional
Pedestrian Directional signs are to be located at each decision point along primary pedestrian paths (or spines) throughout the campus. This sign type includes an orientation map and directions to key destinations.
As a general rule and in order to manage the number of destinations on the various campuses, an overall strategy for pedestrian directional signage has been established:
On the Packer campus it is recommended to use the map/destination as the primary layout to help manage the high number of destinations.
On Sayre it is recommended to use orientation maps only and key touchpoints—this will help manage the number of breadcrumbs needed on Goodman and Packer. A mix of directional layouts can be paired together on one sign or directionals used throughout campus with maps at key locations.
2.11LEHIGH UNIVERSITY | Wayfinding and Signage Manual
SECTION 2 | SIGN SYSTEM OVERVIEW
Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud exercita�on ullamco laboris nisi ut aliquip ex eLorem ipsum
Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud exercita�on ullamco laboris nisi ut aliquip ex eLorem ipsum
Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud exercita�on ullamco laboris nisi ut aliquip ex eLorem ipsum
Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud exercita�on ullamco laboris nisi ut aliquip ex eLorem ipsum
Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud exercita�on ullamco laboris nisi ut aliquip ex eLorem ipsum
Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud exercita�on ullamco laboris nisi ut aliquip ex eLorem ipsum
Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud exercita�on ullamco laboris nisi ut aliquip ex eLorem ipsum
Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud exercita�on ullamco laboris nisi ut aliquip ex eLorem ipsum
Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud exercita�on ullamco laboris nisi ut aliquip ex eLorem ipsum
Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud exercita�on ullamco laboris nisi ut aliquip ex eLorem ipsum
Snack.Study.Sleep.SAYRE PARK
Iacocca HallIacocca Conference CenterBuilding B
Building C
LIVE TRACKING BUS.LEHIGH.EDUMORE INFO LEHIGH.EDU/CONNECTIONS
CAMPUS CONNECTORTO SAUCON VILLAGE
PACKER EXPRESSTO FARRINGTON SQUARE
AccessLUCall (610) 758-4200 to request On−Demand Service. Requests are first−come first−serve.
AlumniMemorialBuilding
VRG.1Parking RegulatorySmall
VRG.4No Smoking RegulatorySmall
VRG.2Parking RegulatoryLarge
PDR.1PedestrianDirectional
GR.1Stair Graphics
IHB.1Information Hub:Multi-sided
IHB.2Information Hub:Single-sided
BUS.1Shuttle Stop Monolith
This Page is Intentionally Left Blank
SECTION 2A
Campus Gateways
2A.2LEHIGH UNIVERSITY | Wayfinding and Signage Manual
A few guidelines to consider when selecting this sign type.
Intended as a landmark element at the primary campus arrival points (Packer, Mountaintop, and Goodman).
These should be located for maximum visibility on approach.
22- Channel LettersPainted fabricated aluminum letterforms. To be externally illuminated. Provide internal structure and bracing, as required by engineering. Mount on aluminum posts welded to Support Plate.
23- Lehigh ShieldFabricated aluminum form, painted, artwork to be provided. Details to be laser cut and chemically welded to aluminum skin. To be externally illuminated. Provide internal structure and bracing, as required by engineering. Mount on aluminum posts welded to Support Plate.
27- Light FixturesHubbell Lighting ALF 12LV-5K-BZ linear LED flood light, or approved similar. Set back 2 feet from sign. Provide necessary electrical components, boxes, wiring, transformers, manual switch and photo sensor switch.
GWY.1 - Signature GatewayGENERAL FABRICATION/GRAPHIC NOTES Field verification of each sign location and site conditions will be required prior to fabrication.
Scale: 1/4" = 1'-0"Front Elevation
1
Scale: 1/4" = 1'-0"Rear Elevation
2
Scale: 1/4" = 1'-0"Left Side Elevation (Shield & Channel Letters)
3Scale: 1/4" = 1'-0"Right Side Elevation (Channel Letters)
4
23
22
P1 P2 P3 P5
P1
22 P1
M1
23 P3
22 P123
27
P3
HH
1'-0" 1'-0"
3'-1
0"3'
-4"
depends on artwork height (approx. 23'-3")
5"GWY.1SECTION 2A | CAMPUS GATEWAYS
2A.3LEHIGH UNIVERSITY | Wayfinding and Signage Manual
Scale: 1/4" = 1'-0"Graphic Layout
5
3'-1
0"
vari
es(2
" m
in.)
3'-4
"
(approx. 2'-10)" 1'-2" depends on artwork height (approx. 19'-4")
3"5"
GWY.1SECTION 2A | CAMPUS GATEWAYS
2A.4LEHIGH UNIVERSITY | Wayfinding and Signage Manual
DO NOT change proportions of shield and LEHIGH.
DO NOT mount on a base.
DO NOT change relationship of shield and LEHIGH.
DO NOT change colors.
GWY.1SECTION 2A | CAMPUS GATEWAYS
2A.5LEHIGH UNIVERSITY | Wayfinding and Signage Manual
A few guidelines to consider when selecting this sign type.
Marks arrival to all campuses at primary and secondary entrance points. This orientation should be used when there is ample real estate to accommodate this sign.
The less urban environments should accept this orientation.
24- Support WallFabricated steel cabinet for support of Channel Letters, painted as per specs. Mount to concrete footing, as required by engineering.
39- Dimensional LettersAluminum letter forms, to be laser cut and painted, as per specs. Stud mount to Support Wall.
44- Light FixturesBega #77917 Rectangular LED In-Grade Floodlight Asymmetrical Flood, Warm White Color (20 7/8" x 3 1/2"), or approved similar.
Bottom of Faceplate sits slightly above finished surface. Provide necessary electrical components, boxes, wiring, transformers, manual switch and photo sensor switch.
49- Channel LettersPainted fab steel letterforms, 1/2" thick faces, 3/16" returns. To be externally illuminated. Provide internal structure and bracing, as required by engineering. Weld 2" O.D. sleeves to bottom of letters and mount on steel posts welded to Support Wall.
50- Lehigh ShieldFabricated steel form, painted, artwork to be provided. Details to be laser cut and welded to first surface. To be externally illuminated. Provide internal structure and bracing, as required by engineering. Mount on steel posts to be direct buried into concrete.
GWY.2 - Secondary Gateway HorizontalGENERAL FABRICATION/GRAPHIC NOTES Field verification of each sign location and site conditions will be required prior to fabrication.
GOODMAN CAMPUS
Scale: 1/4" = 1'-0"Top View
3
Scale: 1/4" = 1'-0"Rear Elevation
2
Scale: 1/4" = 1'-0"Front Elevation
1
50
49
24
P1
50 P3
24 P3
24 P2
P2 P3 P5
P1
P3 24 P2
44
39 P1
P3
M1
24
49
P3
P1
P2 24
K1
K2
1'-3
"
4"
12'-0"
20'-7"
25'-0"
25'-0"
3'-7" 20'-7"
1'-8
"4"
8"
2'-0
"
91/2"
91/2"
3'-1
0"
vari
es(2
" m
in.)
1'-0
"
GWY.2SECTION 2A | CAMPUS GATEWAYS
2A.6LEHIGH UNIVERSITY | Wayfinding and Signage Manual
GOODMAN CAMPUS
3'-1
0"
vari
es(2
" m
in.)
T3
Scale: 1/4" = 1'-0"Graphic Layout
1
4 5 /
8"
10"
3"
2'-6
"
depends on artwork height (approx. 14'-6") (approx.
2'-10)"
alig
nalign
10" 91/2"
GWY.2SECTION 2A | CAMPUS GATEWAYS
2A.7LEHIGH UNIVERSITY | Wayfinding and Signage Manual
DO NOT change proportions of shield and LEHIGH.
DO NOT change relationship of shield and LEHIGH.
DO NOT change colors.
DO NOT change colors.
GOODMAN CAMPUS
GOODMAN CAMPUS
GOODMAN CAMPUS
GOODMAN CAMPUS
GWY.2SECTION 2A | CAMPUS GATEWAYS
2A.8LEHIGH UNIVERSITY | Wayfinding and Signage Manual
A few guidelines to consider when selecting this sign type.
Marks arrival to all campuses at primary and secondary entrance points. This orientation should be used when there is limited real estate to accommodate this sign.
This sign type works well for tight urban environments.
26- Gravel BedProvide stainless steel landscape edging all around and fill with grey river pebbles.
33- Gateway PanelsFabricated aluminum cabinets, paint all exposed surfaces as per specs. Mount on 1/2" aluminum plate fastened to bolts embedded in reinforced concrete foundation, as required by engineering.
34-Dimensional LettersAluminum letter forms, to be laser cut and painted, as per specs. Stud mount to Gateway Panels.
35- Gateway ShieldLaser cut aluminum shape, painted, artwork to be provided. Details to be laser cut and chemically welded. Stud mount to Gateway Panel.
36- Gateway LettersLaser cut aluminum shape, painted, artwork to be provided. Stud mount to Gateway Panel.
45- Light FixturesBega #77008 LED In-Grade Floodlight Asymmetrical Flood with reinforced polyamide housing. Warm White Color, or approved similar. Provide necessary electrical components, boxes, wiring, transformers, manual switch and photo sensor switch.
GWY.3 - Secondary Gateway VerticalGENERAL FABRICATION/GRAPHIC NOTES Field verification of each sign location and site conditions will be required prior to fabrication.
PA
CK
ER C
AM
PU
S
PA
CK
ER C
AM
PU
S
Scale: 1/2" = 1'-0"Front Elevation
1Scale: 1/2" = 1'-0"Rear Elevation
2Scale: 1/2" = 1'-0"Left Side Elevation
3Scale: 1/2" = 1'-0"Right Side Elevation
4
33 P3
33 P1
36 P3
34 P3
33 P2
35
Q1
Q2
Q3
33 P3
33 P1
36 P3
35
34 P3
33
45
P2
33 P3
33 P1
36 P3
35
P1 P2 P3 P5
Q5
14'-
0"
12'-
10"
9'-2
"
10"
1'-0"
1'-10"4" 6"
21/4
"GWY.3SECTION 2A | CAMPUS GATEWAYS
2A.9LEHIGH UNIVERSITY | Wayfinding and Signage Manual
Scale: 1 1/2" = 1'-0"Graphic Layout
2
Scale: 1 1/2" = 1'-0"Graphic Layout
3
T1
Scale: 1" = 1'-0"Top View
1
45
26
33
45
2 1 /
4"10
"3
1 /4" eq. 7" eq.
3"
1 1/2" 4"
eq. 1'-9" eq.
2'-9"7"
2'-4
"7"
3'-6
"GWY.3SECTION 2A | CAMPUS GATEWAYS
2A.10LEHIGH UNIVERSITY | Wayfinding and Signage Manual
DO NOT change colors. DO NOT switch campusand University names.
DO NOT alter Shieldlocation/ scale.
DO NOT include the word “UNIVERSITY”.
DO NOT alter proportions.
PA
CK
ER C
AM
PU
S
PA
CK
ER C
AM
PU
S
PA
CK
ER C
AM
PU
S
PA
CK
ER C
AM
PU
S
PA
CK
ER C
AM
PU
S
GWY.3SECTION 2A | CAMPUS GATEWAYS
2A.11LEHIGH UNIVERSITY | Wayfinding and Signage Manual
26- Gravel BedProvide stainless steel landscape edging all around and fill with grey river pebbles.
33- Gateway PanelsFabricated aluminum cabinets, paint all exposed surfaces as per specs. Mount on 1/2" aluminum plate fastened to bolts embedded in reinforced concrete foundation, as required by engineering.
34-Dimensional LettersAluminum letter forms, to be laser cut and painted, as per specs. Stud mount to Gateway Panels.
35- Gateway ShieldLaser cut aluminum shape, painted, artwork to be provided. Details to be laser cut and chemically welded. Stud mount to Gateway Panel.
45- Light FixturesBega #77008 LED In-Grade Floodlight Asymmetrical Flood, Warm White Color, or approved similar. Bottom of Faceplate sits slightly above finished surface. Provide necessary electrical components, boxes, wiring, transformers, manual switch and photo sensor switch.
A few guidelines to consider when selecting this sign type.
Intended to identify a campus by name. Can be used in conjunction with a Signature Gateway to mark a primary campus arrival.
Can also be used as a standalone element to identify a transition point between campuses.
GWY.4 - Campus IdentificationGENERAL FABRICATION/GRAPHIC NOTES Field verification of each sign location and site conditions will be required prior to fabrication.
SA
YR
E PA
RK
SA
YR
E PA
RK
Scale: 1/2" = 1'-0"Front Elevation
1Scale: 1/2" = 1'-0"Rear Elevation
2Scale: 1/2" = 1'-0"Left Side Elevation
3Scale: 1/2" = 1'-0"Right Side Elevation
4
33 P2
33 P1
35 P1
34 P3
33 P2
33 P1
34 P3
33
45
P2
Q4
35 P1
Q5
1'-2"
1'-0" 8"
1'-2" 4"
3"
9'-2
"
11'-
0"GWY.4SECTION 2A | CAMPUS GATEWAYS
DO NOT change colors. DO NOT switch campusand University names.
DO NOT alter Shieldlocation/ scale.
DO NOT include the word “UNIVERSITY”.
DO NOT alter proportions.
PA
CK
ER C
AM
PU
S
PA
CK
ER C
AM
PU
S
PA
CK
ER C
AM
PU
S
PA
CK
ER C
AM
PU
S
PA
CK
ER C
AM
PU
S
2A.12LEHIGH UNIVERSITY | Wayfinding and Signage Manual
Scale: 1 1/2" = 1'-0"Graphic Layout
2Scale: 1" = 1'-0"Top View
1
T1
45
26
33
45
4 1/4"eq. eq.
3"2
1 /4"
10"
4"
2'-2"
6" 1'-2" 6"
7"2'
-4"
7"
3'-6
"
GWY.4SECTION 2A | CAMPUS GATEWAYS
2A.13LEHIGH UNIVERSITY | Wayfinding and Signage Manual
DO NOT change colors. DO NOT switch campusand University names.
DO NOT alter Shieldlocation/ scale.
DO NOT alter proportions.
SA
YR
E PA
RK
SA
YR
E PA
RK
SA
YR
E PA
RK
GWY.4SECTION 2A | CAMPUS GATEWAYS
Scale: 1 1/2" = 1'-0"Graphic Layout
2Scale: 1" = 1'-0"Top View
1
T1
45
26
33
45
4 1/4"eq. eq.
3"2
1 /4"
10"
4"
2'-2"
6" 1'-2" 6"
7"2'
-4"
7"
3'-6
"
This Page is Intentionally Left Blank
SECTION 2B
Vehicular Wayfinding
2B.2LEHIGH UNIVERSITY | Wayfinding and Signage Manual
A few guidelines to consider when selecting this sign type.
Only used along roadways connecting campuses. These signs are intended to mark the Lehigh Campus as well as connect drivers from one campus to another.
Theses signs are to be single sided messages only, with Brand on the rear elevation.
1- Sign Panel1/4" thick aluminum plates chemically welded to mounting angle. Paint all exposed surfaces. Mechanically fastened to mounting frame. Surface applied graphics.
2- Fabricated Sign Core.063" thick aluminum sheet fastened to 1½" thick aluminum tube frame. Paint all exposed surfaces.
3- Mounting Frame3/4" x 1" x 1/2" Aluminum Arch Angle, miter jointed mechanically fastened to sign core.
4- Mounting Base 1" thick aluminum sheet welded to 1½" aluminum tube. Paint all exposed surfaces and secure to foundation and fabricated sign core.
8- Lehigh Logo 1/8" thick painted aluminum plate with digital printed graphic on face plate adhered to sign core and all exposed edges painted.
43- Lehigh LogoDigital print on vinyl, to be applied to Sign Panel. Artwork to be provided.
CTB.1 - Campus TrailblazerGENERAL FABRICATION/GRAPHIC NOTES Field verification of each sign location and site conditions will be required prior to fabrication.
MOUNTAINTOPCAMPUS
GOODMANCAMPUS
SAYRE PARK
Scale: 1/2" = 1'-0"
Front Elevation1
Scale: 1/2" = 1'-0"
Rear Elevation2
Scale: 1/2" = 1'-0"
Side Elevation3
V1
P1
P1
1
P22
8
sim.C1
A sim.
V6
P32
P34
P11
P1
P32
P34
43
2
1
3 P2
8
P1
P1
P1 P2 P3 P5
1'-0
"
3'-0" 7"
3"
9'-0
"
1"1'
-0"
6'-1
1"
3'-0"
11"
1"
8'-0
"
9'-0
"
7'-6
"1'
-6"
9'-0
"
23/4"23/4"
CTB.1SECTION 2B | VEHICULAR WAYFINDING
NOTE:Prior to manufacturing this sign, the fabricator shall confirm with Lehigh University whether a breakaway design is required.
2B.3LEHIGH UNIVERSITY | Wayfinding and Signage Manual
Scale: NTS
Maintain 9" space from centerof arrow to baseline of first messageas illustrated above
Messages should follow arroworder listed in graphic standardssection page 1C.4
Arrow Detail3
MOUNTAINTOPCAMPUS
GOODMANCAMPUS
SAYRE PARK
Scale: 1/2" = 1'-0"
Graphic Layout (Rear)2
Scale: 1/2" = 1'-0"
Graphic Layout (Front)1
2 1/2" 2 1/2" Min
T2
V1
10 1
/2"
8"
9"5"
3"
11 1
/2"
2 1 /
8"
8"
10 1/2"
7"
6 1 /
2"9"
5"
5 1/2"
8 1 /
2" m
in
CTB.1SECTION 2B | VEHICULAR WAYFINDING
2B.4LEHIGH UNIVERSITY | Wayfinding and Signage Manual
DO NOT use other colors in the yellow or brown color fields.
DO NOT use small pedestrianscale messages on this sign type.
DO NOT increase the yellow or brown color fields/proportions
DO NOT use the word“UNIVERSITY” on the logo.
DO NOT alter the shield/namescale or proportions
DO NOT include brand on signpanel with messasges.
MOUNTAINTOPCAMPUS
GOODMANCAMPUS
SAYRE PARK MOUNTAINTOPCAMPUS
GOODMANCAMPUS
SAYRE PARK SAYRE PARK
Goodman Campus
MOUNTAINTOPCAMPUS
GOODMANCAMPUS
SAYRE PARK
CTB.1SECTION 2B | VEHICULAR WAYFINDING
2B.5LEHIGH UNIVERSITY | Wayfinding and Signage Manual
A few guidelines to consider when selecting this sign type.
Primary vehicular directional to be used throughout campus. This sign type should be positioned to be on the same side of the roadway as the flow of traffic.
Double-sided messaging is only permissible when there are no other options and locating messaging adjacent to the flow of traffic is not possible.
1- Sign Panel1/4" thick aluminum plates chemically welded to mounting angle. Paint all exposed surfaces. Mechanically fastened to mounting frame. Surface applied graphics.
2- Fabricated Sign Core.063" thick aluminum sheet fastened to 1½" thick aluminum tube frame. Paint all exposed surfaces.
3- Mounting Frame3/4" x 1" x 1/2" Aluminum Arch Angle, miter jointed mechanically fastened to sign core.
4- Mounting Base1" thick aluminum sheet welded to 1½" aluminum tube. Paint all exposed surfaces and secure to foundation and fabricated sign core.
VDR.1 - Vehicular Directional: Ground MountedGENERAL FABRICATION/GRAPHIC NOTES Field verification of each sign location and site conditions will be required prior to fabrication.
MOUNTAINTOPCAMPUS
Alumni MemorialBuilding
Visitor Parking
P2
P1
P1
2
1
3 P2
P11
3
Single SidedScale: 1/2" = 1'-0"
Side Elevation
2
Single Sided (Reference)Rear Elevation
4
Double SidedScale: 1/2" = 1'-0"
Side Elevation
3
A/B
Scale: 1/2" = 1'-0"Front and Rear Elevation (Double Sided)
1
C1/D
2
1
2
P3
4 P3
P1
V1
V1
V1
V1
V1
P2
P1
P1
P1
4"3"
7" 7"
1"6"
6'-1
1"11
"1"
8'-6
"
3'-0"
1'-6
"7'
-0"
8'-6
"
23/4"23/4" 23/4"23/4"
VDR.1SECTION 2B | VEHICULAR WAYFINDING
NOTE:Prior to manufacturing this sign, the fabricator shall confirm with Lehigh University whether a breakaway design is required.
2B.6LEHIGH UNIVERSITY | Wayfinding and Signage Manual
Sayre Field
Visitor Parking
IacoccaConference Center Drop-off
Iacocca Hall Drop-off
MOUNTAINTOPCAMPUS
GOODMANCAMPUS
MOUNTAINTOP
Visitor Parking
Alumni Memorial Building
PACKER
SAYRE PARK
MOUNTAINTOPCAMPUS
GOODMANCAMPUS
Visitor Parking
Alumni Memorial Building
PACKER SAYRE PARK
MOUNTAINTOPCAMPUS
Scale: NTS
Maintain 9" space from center of arrow to baseline of first messageas illustrated at left
Messages should followarrow order listed ingraphic standards sectionpage 1C.4
Arrow Detail5
Scale: 1/2" = 1'-0"Graphic Layout
1
Scale: 1/2" = 1'-0"Graphic Layout
3
T1
T4
Scale: 1/2" = 1'-0"Graphic Layout
4
T2
T1
T4
T4
T2
T1
T4
Scale: 1/2" = 1'-0"Alternate Layout
2
T1
T2
2 1/2" 2 1/2 min"
3"
6 1 /
2"9"
2 1 /
4"
4"
8"9"
5"
3"2 1/2" 2 1/2 min"
6 1 /
2"2
1 /4"
9"5"
7 1 /
2"5"
3"3"
8"
5"5"
7 1 /
2"5"
2 1/2" 2 1/2 min"
3"
6 1 /
2"9"
2 1 /
4"
4"
5"7
1 /2"
5"8"
9"7
1 /2"
5"7
1 /2"
5"
3"
5"
5 1/2"
8 1 /
2" m
in
2 1/2" 2 1/2 min"3"
6 1 /
2"9"
2 1 /
4"
4"
5"7
1 /2"
5"8"
9"5"
3"
8 1 /
2" m
in
8 1 /
2" m
in
8 1 /
2" m
in
V1
VDR.1SECTION 2B | VEHICULAR WAYFINDING
2B.7LEHIGH UNIVERSITY | Wayfinding and Signage Manual
MOUNTAINTOPCAMPUS
GOODMANCAMPUS
Visitor Parking
Alumni Memorial Building
Farrington Square
Taylor Gym
PACKER
Visitor Parking
PACKER
MOUNTAINTOPCAMPUS
PACKER
Scale: NTS
Maintain 9" space from centerof arrow to baseline of first messageas illustrated above
Messages should follow arrow order listed in graphic standards section page 1C.4
Arrow Detail4
Scale: 1/2" = 1'-0"Alternate Layout
1
T1
T4T4
T4
Scale: 1/2" = 1'-0"Alternate Layout
2
T2
Scale: 1/2" = 1'-0"Alternate Layout
3
T1
T2
4"
2 1/2" 2 1/2 min"
6 1 /
2"2
1 /4"
9"5"
7 1 /
2"5"
3"
8"9"
4"4"
2 1/2" 2 1/2 min"
6 1 /
2"2
1 /4"
9"5"
3"3"
8"9"
2 1/2" 2 1/2 min"
3"
6 1 /
2"2
1 /4"
4"5"9"
5"7
1 /2"
5"7
1 /2"
8"9"
5"
5 1/2"
5"8"
9"
8 1 /
2" m
in8
1 /2"
min
8 1 /
2" m
in
V1
VDR.1SECTION 2B | VEHICULAR WAYFINDING
2B.8LEHIGH UNIVERSITY | Wayfinding and Signage Manual
SECTION 2B | VEHICULAR WAYFINDING VDR.1
DO NOT use the UniversityShield/Brand on this sign type
DO NOT use small pedestrianscale messages on this sign type
DO NOT increase the yellow or brown color fields/proportions
DO NOT use all caps for anymessages except when noted
DO NOT use other colors in the yellow or brown color fields.
MOUNTAINTOPCAMPUS
Alumni MemorialBuilding
Visitor Parking
MOUNTAINTOPCAMPUS
ALUMNI MEMORIALBUILDING
VISITOR PARKING
MOUNTAINTOPCAMPUS
Alumni Memorial Building
Visitor Parking
MOUNTAINTOPCAMPUS
Alumni MemorialBuilding
Visitor Parking
MOUNTAINTOPCAMPUS
Alumni MemorialBuilding
Visitor Parking
2B.9LEHIGH UNIVERSITY | Wayfinding and Signage Manual
A few guidelines to consider when selecting this sign type.
Used when a smaller footprint is required or the ground mounted condition does not allow for the acceptable traffic sightlines.
The use of this sign type should be limited to meet the needs of urban conditions.
This sign type is intended for single-sided messages only.
16- Fabricated Sign PoleAluminum frame with 1/8" thick aluminum skins. Cap any open ends. Paint all exposed surfaces.
17- Sign Panel1/2" thick aluminum panel. Mask and paint exposed surfaces as shown. Surface applied graphics. Mechanically fasten to Fabricated Sign Pole.
18- Mounting Base1/2" thick aluminum sheet welded to 1" x 3" aluminum tubes. Secure to foundation, mount Fabricated Sign Pole and mechanically fasten. Paint all exposed surfaces.
VDR.2 - Vehicular Directional: Post and Panel (Small)GENERAL FABRICATION/GRAPHIC NOTES Field verification of each sign location and site conditions will be required prior to fabrication.
PACKER
MOUNTAINTOPCAMPUS
Alumni MemorialBuilding
Parking
V1
V1
V1
V1
V1
17
16 P1
P1
17 P2
17
16 P1
18 P1
P1
E
Scale: 1/2" = 1'-0"Front Elevation
1 Scale: 1/2" = 1'-0"Rear Elevation
3Scale: 1/2" = 1'-0"Side Elevation
2
All Sides All Sides
12'-
6 ¼
"
1 ¼
"4'
-11"
7'-6
"
3'-1"
3'-0"
1 ¼
"6"
4'-5
"7'
-6"
2'-71/8" 6"
3'-1"
6"
con
firm
by
eng
inee
rin
g
F
VDR.2SECTION 2B | VEHICULAR WAYFINDING
DO NOT use the UniversityShield/Brand on this sign type
DO NOT use small pedestrianscale messages on this sign type
DO NOT increase the yellow or brown color fields/proportions
DO NOT use all caps for anymessages except when noted
DO NOT use other colors in the yellow or brown color fields.
MOUNTAINTOPCAMPUS
Alumni MemorialBuilding
Visitor Parking
MOUNTAINTOPCAMPUS
ALUMNI MEMORIALBUILDING
VISITOR PARKING
MOUNTAINTOPCAMPUS
Alumni Memorial Building
Visitor Parking
MOUNTAINTOPCAMPUS
Alumni MemorialBuilding
Visitor Parking
MOUNTAINTOPCAMPUS
Alumni MemorialBuilding
Visitor Parking
NOTE:Prior to manufacturing this sign, the fabricator shall confirm with Lehigh University whether a breakaway design is required.
2B.10LEHIGH UNIVERSITY | Wayfinding and Signage Manual
Scale: 1/2" = 1'-0"Graphic Layout
1Scale: 1/2" = 1'-0"Alternate Graphic Layout
2
Scale: NTS
Maintain 9" space from centerof arrow to baseline of first messageas illustrated above
Messages should follow arrow order listed in graphic standards section page 1C.4
Arrow Detail3
MOUNTAINTOPCAMPUS
MOUNTAINTOPCAMPUS
GOODMANCAMPUS
Alumni MemorialBuilding
Parking
SAYRE PARK
T2
V1
T1
T4
T2
T1
T4
2 1/2" 2 1/2 min"
7 1 /
2"6
1 /2"
9"2
1 /4"
5"8"
9"5"
4"
3"3"
3"2 1/2" 2 1/2 min"
7 1 /
2"6
1 /2"
9"2
1 /4"
5"
3"
7 1 /
2"5"
5"
5 1/2"
3 1 /
2"m
in
3 1 /
2"m
in
VDR.2SECTION 2B | VEHICULAR WAYFINDING
2B.11LEHIGH UNIVERSITY | Wayfinding and Signage Manual
DO NOT increase the yellow color field/proportions
DO NOT use the UniversityShield/Brand on this sign type
DO NOT use all caps for anymessages except when noted
DO NOT use other colors in the yellow color field
PACKER
MOUNTAINTOPCAMPUS
Alumni MemorialBuilding
PACKER
MOUNTAINTOPCAMPUS
ALUMNI MEMORIALBUILDING
PACKER
MOUNTAINTOPCAMPUS
Alumni MemorialBuilding
PACKER
Alumni MemorialBuilding
MOUNTAINTOPCAMPUS
VDR.2SECTION 2B | VEHICULAR WAYFINDING
2B.12LEHIGH UNIVERSITY | Wayfinding and Signage Manual
A few guidelines to consider when selecting this sign type.
Used when a smaller footprint is required or the ground mounted condition does not allow for the acceptable traffic sightlines.
The use of this sign type should be limited to meet the needs of urban conditions.
This sign type is intended for single-sided messages only.
16- Fabricated Sign PoleAluminum frame with 1/8" thick aluminum skins. Cap any open ends. Paint all exposed surfaces.
17- Sign Panel1/2" thick aluminum panel. Mask and paint exposed surfaces as shown. Surface applied graphics. Mechanically fasten to Fabricated Sign Pole.
18- Mounting Base1/2" thick aluminum sheet welded to 1" x 3" aluminum tubes. Secure to foundation, mount Fabricated Sign Pole and mechanically fasten. Paint all exposed surfaces.
VDR.3 - Vehicular Directional: Post and Panel (Large)GENERAL FABRICATION/GRAPHIC NOTES Field verification of each sign location and site conditions will be required prior to fabrication.
PACKER
Zoellner Arts Center
Alumni Memorial Building
Visitor Parking
Farrington Square
V1
V1
V1
V1
17
16 P1
P1
17 P2
17 P1
16 P1
17 P2
E
Scale: 1/2" = 1'-0"Front Elevation
1 Scale: 1/2" = 1'-0"Rear Elevation
3Scale: 1/2" = 1'-0"Side Elevation
2
All Sides
All Sides
18 P1
14'-
4"
3'-1"
3'-0" 2'-7" 6"
3'-1"
6"
6'-1
0"7'
-6"
6"6'
-3"
7'-6
"1
¼"
con
firm
by
eng
inee
rin
g
F
VDR.3SECTION 2B | VEHICULAR WAYFINDING
NOTE:Prior to manufacturing this sign, the fabricator shall confirm with Lehigh University whether a breakaway design is required.
2B.13LEHIGH UNIVERSITY | Wayfinding and Signage Manual
Scale: 1/2" = 1'-0"Alternate Graphic Layout
3Scale: 1/2" = 1'-0"Alternate Graphic Layout
4
Visitor Parking
Scale: 1/2" = 1'-0"Graphic Layout
1Scale: 1/2" = 1'-0"Alternate Graphic Layout
2
Zoellner Arts Center
Scale: NTS
Arrow Detail5
Maintain 9" space from centerof arrow to baseline of first messageas illustrated above
Messages should follow arrow order listed in graphic standards section page 1C.4
Farrington Square
Visitor Parking
Alumni Memorial Building
Visitor Parking
Alumni Memorial Building
Visitor Parking
Farrington Square
Taylor Gym
Zoellner Arts Center
Alumni Memorial Building
MOUNTAINTOPCAMPUS
Alumni MemorialBuilding
Parking
T1
T4
T1
T4
T1
T4
V1
T2
T1
T4
2 1/2" 2 1/2 min"
7 1 /
2"6
1 /2"
9"2
1 /4"
5"
4"
3"
5"8"
9"5"
7 1 /
2"5"
2 1/2" 2 1/2 min"
7 1 /
2"6
1 /2"
9"2
1 /4"
5"
4"
3"
2 1/2" 2 1/2 min"
6 1 /
2"9"
2 1 /
4"
4"
3"
7 1 /
2"5"
7 1 /
2"5"
8"9"
5"
5"8"
9"5"
7 1 /
2"5"
5"
5 1/2"
2 1/2" 2 1/2 min"
7 1 /
2"6
1 /2"
9"2
1 /4"
5"8"
9"5"
4"
3"3"
3"
3 1 /
2"m
in3
1 /2"
min
3 1 /
2"m
in3
1 /2"
min
VDR.3SECTION 2B | VEHICULAR WAYFINDING
2B.14LEHIGH UNIVERSITY | Wayfinding and Signage Manual
VDR.3SECTION 2B | VEHICULAR WAYFINDING
DO NOT increase the yellow color field/proportions
DO NOT use the UniversityShield/Brand on this sign type
DO NOT use all caps for anymessages except when noted
DO NOT use other colors in the yellow color field
PACKER
Zoellner Arts Center
Alumni Memorial Building
Visitor Parking
Farrington Square
PACKER
Zoellner Arts Center
Alumni Memorial Building
Visitor Parking
Farrington Square
PACKER
Zoellner Arts Center
Alumni Memorial Building
Visitor Parking
Farrington Square
PACKER
ZOELLNER ARTS CENTER
ALUMNI MEMORIAL BUILDING
FARRINGTON SQUARE
2B.15LEHIGH UNIVERSITY | Wayfinding and Signage Manual
16- Fabricated Sign PoleAluminum frame with 1/8" thick aluminum skins. Cap any open ends. Paint all exposed surfaces.
17- Sign Panel1/2" thick aluminum panel. Mask and paint exposed surfaces as shown. Surface applied graphics. Mechanically fasten to Fabricated Sign Pole.
VRG.3 - Street NameGENERAL FABRICATION/GRAPHIC NOTES Field verification of each sign location and site conditions will be required prior to fabrication.
A few guidelines to consider when selecting this sign type.
Street signs are to be used on Lehigh University owned streets to help define the campus edge.
UNIVERSITY DR. UNIVERSITY DR.QUAD DR.E
18 P1
All SidesAll Sides
A A
A
A
B
A
B
A
B
B B
B
8'-7
"
1¼"
3'-1¼"
3'-0" 2'-7" 6"
3'-1"
6"
6"8'
-0"
8'-0
"
16 P1
17
P2V6
16
17 17
16 16
16
17
P1
Scale: 1/2" = 1'-0"Front Elevation
1 Scale: 1/2" = 1'-0"Rear Elevation
3
Scale: 1/2" = 1'-0"Top View
4
Scale: 1/2" = 1'-0"Side Elevation
2
con
firm
by
eng
inee
rin
g
VRG.3SECTION 2B | VEHICULAR WAYFINDING
NOTE:Prior to manufacturing this sign, the fabricator shall confirm with Lehigh University whether a breakaway design is required.
2B.16LEHIGH UNIVERSITY | Wayfinding and Signage Manual
UNIVERSITY DR
UNIVERSITY DR
Scale: 11/2" = 1'-0"Graphic Layout (Side A & B)
Side A
Side B
Abbreviation GuidelinesStreet = ST.Avenue = AVE.Drive = DR.Road = RD.North = N.South = S.East = E.West = W.
1
UNIVERSITY DR.
2 1/2"
2 1 /
4" T4
7 1/2" min.
+60 Tracking
VRG.3SECTION 2B | VEHICULAR WAYFINDING
2B.17LEHIGH UNIVERSITY | Wayfinding and Signage Manual
DO NOT increase the yellow color field/proportions
DO NOT use the UniversityShield/Brand on this sign type
DO NOT use other colors in the yellow color field
UNIVERSITY DRUNIVERSITY DRUNIVERSITY DR
VRG.3SECTION 2B | VEHICULAR WAYFINDING
UNIVERSITY DR
UNIVERSITY DR
Scale: 11/2" = 1'-0"Graphic Layout (Side A & B)
Side A
Side B
Abbreviation GuidelinesStreet = ST.Avenue = AVE.Drive = DR.Road = RD.North = N.South = S.East = E.West = W.
1
UNIVERSITY DR.
2 1/2"
2 1 /
4" T4
7 1/2" min.
+60 Tracking
This Page is Intentionally Left Blank
SECTION 2C
Building Identification
2C.2LEHIGH UNIVERSITY | Wayfinding and Signage Manual
1- Sign Panel1/4" thick aluminum plates chemically welded to mounting angle. Paint all exposed surfaces. Mechanically fastened to mounting frame. Surface applied graphics.
2- Fabricated Sign Core.063" thick aluminum sheet fastened to 1½" thick aluminum tube frame. Paint all exposed surfaces.
3- Mounting Frame3/4" x 1" x 1/2" Aluminum Arch Angle, miter jointed mechanically fastened to sign core.
4- Mounting Base1/2" thick aluminum sheet chemically welded to 1½" aluminum tube. Paint all exposed surfaces and secure to foundation and fabricate sign core.
SECTION 2C | SIGN TYPE DRAWINGS BID.1
BID.1 - Building Identification: PedestrianGENERAL FABRICATION/GRAPHIC NOTES Field verification of each sign location and site conditions will be required prior to fabrication.
A few guidelines to consider when selecting this sign type.
This sign type is to be programmed and used to mark a building visible from a pedestrian approach.
Program and locate this sign to maximize visbility from all pedestrian approaches and with enough ambient light to maximize visibility both day/night.
Single-sided configurations made be used when the second sign face is oriented away from pedestrian view.
Scale: 3/4" = 1'-0"Front and Rear Elevation
1 Single SidedScale: 3/4" = 1'-0"
Side Elevation
2Double SidedScale: 3/4" = 1'-0"
Side Elevation
3
4
1
2
2
2
1 1
33
61 University Dr.
Accessible Entrance onopposite side of building
No Smoking within 25ft of building
Sherman FairchildCenter
For the PhysicalSciences
61
P3
P3
P1
V2
V4
V4
V4
V4
V5
P2
6'-0
"
1'-6"
P2
1"1'
-0"
3"4'
-8"
P2
P1
P1 P1
4"2 3/4"
7" 7"A/B
1'-6
"
1"11
"
23/4"23/4" 23/4"23/4"
This message can be added to achieve LEED points.
P1
Single Sided (Reference)Rear Elevation
4
P1
P1
2C.3LEHIGH UNIVERSITY | Wayfinding and Signage Manual
Scale: 3/4" = 1'-0"When identifying an accessible entrance, the handicap symbol is consistently placed 5" below the last line of the building name.
Graphic Layout1
Scale: 3/4" = 1'-0"When identifying an accessible entrance, the handicap symbol is consistently placed 5" below the last line of the building name.
Graphic Layout4
Scale: 3/4" = 1'-0"When directing to an accessible entrance, the handicap/arrow symbols are placed between the building sublistings and building address.
Graphic Layout2
Scale: 3/4" = 1'-0"
Graphic Layout Detail5
Scale: NTS
Arrow Detail6
Scale: 3/4" = 1'-0"When directing to an accessible entrance, the handicap/arrow symbols are placed between the building sublistings and building address.
Graphic Layout3
Two Line Building Name
Two Line Address
Building Name
One Line Sublisting
Two LineAddress
Accessible Entrance Location Information
Three Line Building Name Here
Two LineSublisting
Two LineSublisting
One Line Sublisting
Two Line Address
Accessible EntranceLocation Information
Four to FiveLineBuildingName Here
Two LineAddress
00
00 00
00
Two LineSublisting
No Smoking within 25ft of building
No Smoking within 25ft of building
No Smoking within 25ft of building
No Smoking within 25ft of building
5
5
1 1/2" 1'-3" 1 1/2" 1 1/2" 1'-3" 1 1/2"
1 1/2" 1'-3" 1 1/2" 1 1/2" 1'-3" 1 1/2"
3"2"
8" M
in
1 3 /
4"
11/4
"4"
2 3 /
4"
2 3 /
4"1
1 /4"
21/2
" 2"
21/2
" 2"
2 3 /
4"2
3 /4"
2 3 /
4"2 3 /
4"H
old
5"
fro
m la
stlin
e o
f C
op
y
Ho
ld 5
"fr
om
last
line
of
Co
py
2"8"
Min
4"11
/4"
1 1 /
4"1
3 /4"
1 3 /
4"
2 3 /
4"2
3 /4"
2"2
3 /4"
2"23
/4"
21/2"
min
2"1
1 /2"
5" 5"
2"8"
Min
1 1 /
4"1"
21/2
"
2"11
/2" 1"
5"
21/2
"1"
1"21
/2"
1"1"
21/2
"1"
1"
1 1 /
4"4"
4"2"
1 1 /
2" 1"
T2
T1
T2
T2
T1
T1
T2
T2
T1
T1
T1
T2
T1
T1
T2
T2
4 1 /
2"
4 1 /
2"4
1 /2"
4"
4 1 /
2"2"
4"
2 1 /
2"
1 1/2"
3/4"1
3 /4"
2"
5"2"
8" M
in
1 1 /
4"4"
2"2"
2"
1 1 /
2"
1 5/8"
V4
V4
SECTION 2C | SIGN TYPE DRAWINGS BID.1
2C.4LEHIGH UNIVERSITY | Wayfinding and Signage Manual
BID.1
DO NOT increase the yellow or brown color fields/proportions
DO NOT move the building number or accessible entrancesymbol to other areas on the sign
DO NOT use the UniversityShield on signs located withinthe campus
DO NOT use large vehicular scale messages on this sign type
DO NOT use other colors in the yellow or brown color fields.
DO NOT use all caps for anymessages except when noted
ShermanFairchildCenter
For the PhysicalSciences
61 University Dr.
Accessible Entrance on Side of Building
61
SHERMANFAIRCHILDCENTER
FOR THE PHYSICALSCIENCES
61 University Dr.
Accessible Entrance on Side of Building
61
ShermanFairchildCenter
For the PhysicalSciences
61 University Dr.
Accessible Entrance on Side of Building
61
ShermanFairchildCenter
For the PhysicalSciences
61 University Dr.
Accessible Entrance on Side of Building
61
ShermanFairchildCenter
For the PhysicalSciences
61 University Dr.
Accessible Entrance on Side of Building
61
Sherman FairchildCenter
61 University Dr.
61
SECTION 2C | SIGN TYPE DRAWINGS
2C.5LEHIGH UNIVERSITY | Wayfinding and Signage Manual
1- Sign Panel1/4" thick aluminum plates chemically welded to mounting angle. Paint all exposed surfaces. Mechanically fastened to mounting frame. Surface applied graphics.
2- Fabricated Sign Core.063" thick aluminum sheet fastened to 1½" thick aluminum tube frame. Paint all exposed surfaces.
3- Mounting Frame3/4" x 1" x 1/2" Aluminum Arch Angle, miter jointed mechanically fastened to sign core.
4- Mounting Base1/2" thick aluminum sheet chemically welded to 1½" aluminum tube. Paint all exposed surfaces and secure to foundation and fabricate sign core.
A few guidelines to consider when selecting this sign type.
This sign type is to be programmed and used to mark a building/building driveway visible from a roadway.
This sign type should alway use refelctive vinyl to maximize visibility at all times of day/night.
Program and locate this sign to maximize visbility from all vehicular approaches.
NOTE:Prior to manufacturing this sign, the fabricator shall confirm with Lehigh University whether a breakaway design is required.
BID.2 - Building Identification: VehicularGENERAL FABRICATION/GRAPHIC NOTES Field verification of each sign location and site conditions will be required prior to fabrication.
Double SidedScale: 3/4" = 1'-0"
Side Elevation
2 Single SidedScale: 3/4" = 1'-0"
Side Elevation
3
A/B
V5
RauchBusinessCenter
6161 University Dr.
2
1
3 P2
P1
P1
2 3/4"
7"
Scale: 3/4" = 1'-0"Front and Rear Elevation
1
V1
P3
2'-6"
V1
V5
3
2
2
2
P3
P1
P2
P2
P1
41'-0
"4'
-10"
1 /4"
1"3"
1'-6
"
4"
7"
1
2
6'-2
"
1"11
"
23/4" 23/4" 23/4" 23/4"
P1
Single Sided (Reference)Rear Elevation
4
P1
P1
SECTION 2C | SIGN TYPE DRAWINGS BID.2
2C.6LEHIGH UNIVERSITY | Wayfinding and Signage Manual
Building Name
One Line Sublisting
One Line Address
00
Four or Five LineBuilding NameGoesHere
Two Line Sublisting
00One Line Address
One Line Address
Scale: 3/4" = 1'-0"
Graphic Layout1
Scale: 3/4" = 1'-0"The shield layout is used only when the building is located outside of the campus perimeter.
Graphic Layout3
Scale: 3/4" = 1'-0"
Graphic Layout2
Three or Four LineBuilding Name Here
00
T2
T2
T1
T2
T1
T2
T1
D3 D7 D8
T1
T1
T2
T2
2 1/2" 2'-1" 2 1/2"
2 1/2" 2'-1" 2 1/2"
2 1/2" 2'-1" 2 1/2"
5 1 /
2"4
1 /2"
4 1 /
2"4
1 /2"
4 1 /
2"
Ho
ld 5
"fr
om
Last
Lin
e o
f C
op
y
21/2
"7"
Min
5 1 /
2"H
old
5"
fro
mLa
stLi
ne
of
Co
py
7" M
in
3"11
/2"
1 1 /
2"4"
3"
11/2
"
1 1 /
2"4"
2" 2"
5 1 /
2"4
1 /2"
4 1 /
2"4
1 /2"
Ho
ld 1
0"fr
om
last
lin
e o
f co
py
11 3
/4"
3"7"
7" M
in
1 1 /
2"4"
2"
Building Name
One Line Sublisting
One Line Address
00
Four or Five LineBuilding NameGoesHere
Two Line Sublisting
00One Line Address
One Line Address
Scale: 3/4" = 1'-0"
Graphic Layout1
Scale: 3/4" = 1'-0"The shield layout is used only when the building is located outside of the campus perimeter.
Graphic Layout3
Scale: 3/4" = 1'-0"
Graphic Layout2
Three or Four LineBuilding Name Here
00
T2
T2
T1
T2
T1
T2
T1
D3 D7 D8
T1
T1
T2
T2
2 1/2" 2'-1" 2 1/2"
2 1/2" 2'-1" 2 1/2"
2 1/2" 2'-1" 2 1/2"5
1 /2"
4 1 /
2"4
1 /2"
4 1 /
2"4
1 /2"
Ho
ld 5
"fr
om
Last
Lin
e o
f C
op
y
21/2
"7"
Min
5 1 /
2"H
old
5"
fro
mLa
stLi
ne
of
Co
py
7" M
in
3"11
/2"
1 1 /
2"4"
3"
11/2
"
1 1 /
2"4"
2" 2"
5 1 /
2"4
1 /2"
4 1 /
2"4
1 /2"
Ho
ld 1
0"fr
om
last
lin
e o
f co
py
11 3
/4"
3"7"
7" M
in
1 1 /
2"4"
2"
BID.2SECTION 2C | SIGN TYPE DRAWINGS
2C.7LEHIGH UNIVERSITY | Wayfinding and Signage Manual
DO NOT increase the yellow or brown color fields/proportions
DO NOT move the building number to other areason the sign
DO NOT use the UniversityShield on signs located withinthe campus
DO NOT use small pedestrianscale messages on this sign type
DO NOT use all caps for anymessages except when noted
DO NOT use other colors in the yellow or brown color fields.
RauchBusinessCenter
61 University Dr.
RauchBusinessCenter
61 University Dr.
61
61
RAUCHBUSINESSCENTER
61 UNIVERSITY DR.
61
RauchBusinessCenter
61 University Dr.
61
RauchBusinessCenter
61 University Dr.
61
RauchBusinessCenter
61 University Dr.
61
SECTION 2C | SIGN TYPE DRAWINGS BID.2
2C.8LEHIGH UNIVERSITY | Wayfinding and Signage Manual
5- Stud MountSign panel/letterforms to be drilled and tapped to receive threaded studs. Drill wall and set with clear epoxy.
6- Spacer1/2" aluminum spacer.
9- Back Plate3/4" thick aluminum milled to shape shown. Paint all exposed surfaces.
10- Sign Panel3/8" thick aluminum sheet with surface applied graphics. Paint all exposed surfaces
A few guidelines to consider when selecting this sign type.
This sign type is to be programmed and used to mark a building entry.
Program and locate this sign next to the entry way (preferably to the right of the entrance), and identify the building name, number, and entrance (i.e. main, accessible, etc.).
BID.3 - Building Identification: Wall MountedGENERAL FABRICATION/GRAPHIC NOTES Field verification of each sign location and site conditions will be required prior to fabrication.
TaylorGym
Accessible Entrance on opposite side of building
9
10 P1P1
P1
P3
V2
P2
V4
V4
V5
No Smoking within 25ft of building
Scale: 1 1/2" = 1'-0"Front Elevation
1
Scale: 1 1/2" = 1'-0"
Side Elevation2
9
10
5
6
3/4"1'- 1"
2'-6
1/2
"
3 /4"
1 1 /
2"2'
-2"
2 1 /
4"
1/2"
This message can be added to achieve LEED points.
P1
P1
BID.3SECTION 2C | SIGN TYPE DRAWINGS
2C.9LEHIGH UNIVERSITY | Wayfinding and Signage Manual
Scale: NTS
Arrow Detail6
Accessible Entrance Location Information
Accessible Entrance Location Information
One Line Sublisting
Two LineSublisting
One Line Sublisting
Three or Four LineBuilding Name Here
00
00
00
Two LineBuilding Name
One Line Sublisting
One Line Sublisting
Two LineSublisting
00
Building NameThree Line Building Name
No Smoking within 25ft of building
No Smoking within 25ft of building
No Smoking within 25ft of building
Scale: 1 1/2" = 1'-0"The shield layout is used only when the building is located outside of the campus perimeter.
Graphic Layout1
Scale: 1 1/2" = 1'-0"When directing to an accessible entrance, the handicap/arrow symbols are placed between the building sublistings and building address.
Graphic Layout3
Scale: 3" = 1'-0"
Symbol Detail5
Scale: 1 1/2" = 1'-0"When identifying an accessible entrance, the handicap symbol is consistently placed 3¼" below the last line of the building name.
Graphic Layout4
Scale: 1 1/2" = 1'-0"When identifying an accessible entrance, the handicap symbol is consistently placed ¾" below the last line of the building name.
Graphic Layout2
3"2"
2"2"
Ho
ld 4
1/2
"fr
om
last
lin
e o
f co
py
2 1 /
2" M
in1
1 /2"
1"4"
Min
1 1 /
4"13
/4"
5 /8"
1 1 /
2"
1" 1"11" 1" 1"11"
3"2"
2"1
1 /2"
11/4
"1"
3"2"
2"2
1 /2"
1 1 /
2"1"
4" M
in
1 1 /
2"1
1 /4"
1"1
3 /4"
1" 1"11"
T2
T1
T2
T2
T2
T1
T2
T1
T1
4
T2
1 1 /
2"1
1 /2"
4
1 3 /
4"
1"
1/2"
1"
11/4"
Ho
ld 3
¼"
fro
m la
stlin
e o
f co
py
2"
1" 1"11"
3"
2"2"
11/2
"11
/4"
1"
T2
T1
T2
Ho
ld 3
¼"
fro
m la
stlin
e o
f co
py
2"
13/4
"13
/4"
V4
V4
D3 D7 D8
1 1 /
2"1"
4" M
in
11/2
"11
/4"
1 1 /
2"13
/4"1
3 /4"
Min
13/4
"13 /
4"M
in
1 1 /
2"1
1 /2"
1"4"
Min
1 1 /
2"13
/4"1
3 /4"
Min
1 1 /
2"
1"
SECTION 2C | SIGN TYPE DRAWINGS BID.3
2C.10LEHIGH UNIVERSITY | Wayfinding and Signage Manual
DO NOT increase the yellow or brown color fields/proportions
DO NOT move the building number to other areason the sign
DO NOT use the UniversityShield unless the building is located outside of the campus perimeter
DO NOT move the accessibleentrance symbol to other areas on the sign
DO NOT use all caps for anymessages except when noted
DO NOT use other colors in the yellow or brown color fields.
One Line Sublisting
One Line Sublisting
Two LineSublisting
61
Taylor Gym
TAYLORGYM
ACCESSIBLE ENTRANCE LOCATION INFORMATION
61
TaylorGym
Accessible Entrance Location Information
61
TaylorGym
Accessible Entrance Location Information
61
TaylorGym
Accessible Entrance Location Information
61
TaylorGym
Accessible Entrance Location Information
61
SECTION 2C | SIGN TYPE DRAWINGS BID.3
2C.11LEHIGH UNIVERSITY | Wayfinding and Signage Manual
N.T.S.BID.3 Install Elevation
1Install to right of entry doors as shown.
TaylorGym
Accessible Entrance on opposite side of building
No Smoking within 25ft of building
10"
3'-6
"
BID.3SECTION 2C | SIGN TYPE DRAWINGS
2C.12LEHIGH UNIVERSITY | Wayfinding and Signage Manual
5- Stud MountSign panel/letterforms to be drilled and tapped to receive threaded studs. Drill wall and set with clear epoxy.
6- Spacer1/2" aluminum spacer.
7- Dimensional LettersLaser cut aluminum or acrylic letter forms. Acrylic letters to be painted, aluminum letters to have brushed horizontal finish with clear coat. Finish specified in copy list.
A few guidelines to consider when selecting this sign type.
Dimensional letters are to be programmed and used to mark a building name on the facade of the building, often the full building donor name.
These can be sized and located above or next to the building entry or on a higher building elevation for greater visibility across campus.
BID.4 / PID.4 - Building and Parking Identification: Dimensional LettersGENERAL FABRICATION/GRAPHIC NOTES Field verification of each sign location and site conditions will be required prior to fabrication.
Scale: NTS
BID.4- Front Elevation1
Scale: NTS
BID.4- Side Elevation2
NOTE:Use Viewing Distance Guidelines chart to determine appropriateletter height per location based on visibility.
Materials and finish selectionto be made based on mountingsurface materials for maximum contrast and legibility.
5
7
6
7 P1 M1 M2P4 Colors/finishesvary by location
Wall Surface
ALUMNI MEMORIAL BUILDING
Vari
es
Thicknessvaries
based onoverall
letterheight
BID.4/PID.4SECTION 2C | SIGN TYPE DRAWINGS
2C.13LEHIGH UNIVERSITY | Wayfinding and Signage Manual
Visibility Chart4
Letter Height = X
3 inches
4 inches
6 inches
8 inches
9 inches
10 inches
12 inches
15 inches
18 inches
24 inches
30 inches
36 inches
42 inches
48 inches
54 inches
60 inches
Best Impact
30 feet
40 feet
60 feet
80 feet
90 feet
100 feet
120 feet
150 feet
180 feet
240 feet
300 feet
360 feet
420 feet
480 feet
540 feet
600 feet
Max Readable Distance
100 feet
150 feet
200 feet
350 feet
400 feet
450 feet
525 feet
630 feet
750 feet
1000 feet
1250 feet
1500 feet
1750 feet
2000 feet
2250 feet
2500 feet
BUILDING NAME
BUILDING NAMELINE TWO
BUILDING NAMELINE TWO
Scale: NTSMaintain same margins when mounting letters right aligned on buildings
BID4: Typical Horizontal Left Align Mounting Elevation1
Scale: NTSMaintain same margins when mounting letters right aligned on buildings
BID4: Typical Two Line Left Align Mounting Elevation2
XX
Min
..2
5X
Scale: NTS
BID4: Typical Two Line Center Align Mounting Elevation3
Min
. 2X
Min
. 2X
X
Min. 2X
Min. 2X
XX
Min
..2
5XM
in. 2
X
SECTION 2C | SIGN TYPE DRAWINGS BID.4/PID.4
2C.14LEHIGH UNIVERSITY | Wayfinding and Signage Manual
BID.5- Building Identification: Vinyl LettersGENERAL FABRICATION/GRAPHIC NOTES Field verification of each sign location and site conditions will be required prior to fabrication.
12 - Vinyl MessageSecond surface applied opaque vinyl copy in color specified.
Artwork to be provided for logo.
A few guidelines to consider when selecting this sign type.
Vinyl Letters are to be programmed and used at glass entries to provide supplemental regulatory information.
One Line NameBuilding HoursMon-Thurs 0:00–0:00Fri-Sat 0:00–0:00Sun 0:00–0:00
00
One Line NameBuilding HoursMon-Thurs 0:00–0:00Fri-Sat 0:00–0:00Sun 0:00–0:00
One Line NameBuilding Hours
Mon-Thurs 0:00–0:00Fri-Sat 0:00–0:00
Sun 0:00–0:00
12
V3
12
V3
Use on glass doors at entrywayLocations will vary
Elevation (Left Align to Handle)1
5'-6
" to
th
e to
p (
typ
ical
)
4" min
Use on glass doors at entrywayLocations will vary
Elevation (Right Align to Handle)2
Install on right door, left aligned
Elevation (Double Door)3
5'-6
" to
th
e to
p (
typ
ical
)
4" min
Optional building ID number shown
NOTE: Vinyl color for best contrast on glass will vary per location. White vinyl will typically provide the best contrast, but there may be situations where black vinyl may work better.
Review site conditions and select color as required for legibility and contrast.
BID.5SECTION 2C | SIGN TYPE DRAWINGS
2C.15LEHIGH UNIVERSITY | Wayfinding and Signage Manual
BID.5SECTION 2C | SIGN TYPE DRAWINGS
One Line NameBuilding HoursMon-Thurs 0:00-0:00Fri-Sat 0:00-0:00Sun 0:00-0:00
00
Two Line NameExampleBuilding HoursMon-Thurs 0:00-0:00Fri-Sat 0:00-0:00Sun 0:00-0:00
One Line NameMAIN ENTRANCE
Two Line NameExampleMAIN ENTRANCENo Smoking within
25ft of buildingNo Smoking within 25ft of building
T2
T2
V3
V3
V3
V3
T1
T1
12
12
T2V3
V3 T1
12
12
T2V3
V3 T1
12
12
12
12
Scale: 1" = 1'-0"
BID5: Typical One Line Layout1
31/2
"21
/2"
21/2
"21
/2"
Scale: 1" = 1'-0"
BID5: Typical Two Line Layout2
3"31
/2"
21/2
"
Scale: 1" = 1'-0"
BID5: Typical One Line Layout3
Scale: 1" = 1'-0"
BID5: Typical Two Line Layout4
31/2
"31
/4"
3"31
/2"
31/4
"
2"2"
11/4
" 2"11
/4"
2"11
/4"
11/4
"3"
3"
4 1 /
2"
4 1 /
2"
3 1 /
2"
4 1 /
2"
3 1 /
2"
4 1 /
2"
3 1 /
2"3
1 /2"
Typ.
6 3 /
4"
4" Optional building ID number
1" Cap Height
1" Cap HeightThis message can be added to achieve LEED points.
2C.16LEHIGH UNIVERSITY | Wayfinding and Signage Manual
ONE LINE NAMEBuilding HoursMon-Thurs 0:00-0:00Fri-Sat 0:00-0:00Sun 0:00-0:00
One Line NameBuilding HoursMon-Thurs 0:00-0:00Fri-Sat 0:00-0:00Sun 0:00-0:00
One Line NameBuilding HoursMon-Thurs 0:00-0:00Fri-Sat 0:00-0:00Sun 0:00-0:00
00
DO NOT use all caps for anymessages except when noted
DO NOT use building addressnumber smaller than 4"
DO NOT use the shield withoutthe full logo lockup
BID.5SECTION 2C | SIGN TYPE DRAWINGS
2C.17LEHIGH UNIVERSITY | Wayfinding and Signage Manual
1- Sign Panel1/4" thick aluminum plates chemically welded to mounting angle. Paint all exposed surfaces. Mechanically fastened to mounting frame.
2- Fabricated Sign Core.063" thick aluminum sheet fastened to 1 1/2" thick aluminum tube frame. Paint all exposed surfaces.
3- Mounting Frame3/4" x1" x 1/4" aluminum angle, miter jointed mechanically fastened to fabricated sign core and sign panel mounting angle.
4- Fabricated Base1/2" thick aluminum sheet chemically welded to 1 1/2" aluminum tube. Paint all exposed surfaces and secure to foundation and fabricated sign core.
A few guidelines to consider when selecting this sign type.
This sign type is to be programmed and used to mark a housing entry.
Program and locate this sign next to the entry way (preferably to the right of the entrance), and identify the house number, accessiblility for handicap, and house address.
Lehigh University is required by the city to provide a minimum 4" building number for use by emergency vehicles.
107 Hill Dr.
House107
2
1 1
33 P2P2
P1
P1 P1
P3
P3
P1
V4
V2
P2
4
1
2
2
Scale: 3/4" = 1'-0"Front and Rear Elevation
1 Single SidedScale: 3/4" = 1'-0"
Side Elevation
2Double SidedScale: 3/4" = 1'-0"
Side Elevation
3
A/B
1'-6"
1"1'
-0"
3"
4"3"
7" 7"
1'-6
"
4'-6
"
1"11
"
23/4" 23/4" 23/4" 23/4"
P1
P1
Single Sided (Reference)Rear Elevation
4
P1
BID.6 - Building Identification: Greek HousingGENERAL FABRICATION/GRAPHIC NOTES Field verification of each sign location and site conditions will be required prior to fabrication.
BID.6SECTION 2C | SIGN TYPE DRAWINGS
NOTE:Prior to manufacturing this sign, the fabricator shall confirm with Lehigh University whether a breakaway design is required.
2C.18LEHIGH UNIVERSITY | Wayfinding and Signage Manual
107 Hill Dr.
House107
107 Hill Dr.
House107
Scale: 3/4" = 1'-0"
Graphic Layout1
T2
T1
Scale: 3/4" = 1'-0"
Alternate Graphic Layout2
T2
T1
1 1/2" 1 1/2" min.
1 1 /
2"
5"5
1 /2"
2'-0
"4"
2 3 /
4"
1 1/2" 1 1/2" min.
1 1 /
2"
5"5
1 /2"
5"1'
-7"
4"
3"4"
3"4"
BID.6SECTION 2C | SIGN TYPE DRAWINGS
2C.19LEHIGH UNIVERSITY | Wayfinding and Signage Manual
107 Hill Dr.
House107
107 Hill Dr.
House107
Scale: 3/4" = 1'-0"
Graphic Layout1
T2
T1
Scale: 3/4" = 1'-0"
Alternate Graphic Layout2
T2
T1
1 1/2" 1 1/2" min.
1 1 /
2"
5"5
1 /2"
2'-0
"4"
2 3 /
4"
1 1/2" 1 1/2" min.
1 1 /
2"
5"5
1 /2"
5"1'
-7"
4"
3"4"
3"4"
BID.6SECTION 2C | SIGN TYPE DRAWINGS
DO NOT use the UniversityShield/Brand on this sign type
DO NOT increase the yellow or brown color fields/proportions
DO NOT use all caps for anymessages except when noted
DO NOT use other colors in the yellow or brown color fields.
House107
107 Hill Dr.
House107
107 Hill Dr.
House107
107 Hill Dr.
HOUSE107
107 Hill Dr.
2C.20LEHIGH UNIVERSITY | Wayfinding and Signage Manual
A few guidelines to consider when selecting this sign type.
This sign type is to be programmed and used to mark a housing entry.
Program and locate this sign next to the entry door (preferably to the right of the entrance), and identify the house number.
Lehigh University is required by the city to provide a minimum 4" building number for use by emergency vehicles.
BID.7 - Building Identification: Wall Mounted AddressGENERAL FABRICATION/GRAPHIC NOTES Field verification of each sign location and site conditions will be required prior to fabrication.
5- Stud MountSign panel/letterforms to be drilled and tapped to receive threaded studs. Drill wall and set with clear epoxy.
6- Spacer1/2" aluminum spacer.
9- Back Plate3/4" thick aluminum milled to shape shown. Paint all exposed surfaces.
10- Sign Panel3/8" thick aluminum sheet with surface applied graphics. Paint all exposed surfaces
SECTION 2C | SIGN TYPE DRAWINGS BID.7
107 5
6
10 P1
9 P1P1
V2
P2
10
9 P1
P1
Scale: 3" = 1'-0"Front Elevation
1
Scale: 3" = 1'-0"Side Elevation
2
1"1
1 /2"
11 1
/2"
1'-0"
1'-2
"
1"
1/4"
3/4"
2C.21LEHIGH UNIVERSITY | Wayfinding and Signage Manual
107Scale: 3" = 1'-0"
Graphic Layout 11
T2
3 3 /
4"4"
3 3 /
4"
SECTION 2C | SIGN TYPE DRAWINGS BID.7
2C.22LEHIGH UNIVERSITY | Wayfinding and Signage Manual
SECTION 2C | SIGN TYPE DRAWINGS BID.7
DO NOT increase the yellow fields/proportions
DO NOT use the University Shield/Brand on this sign type
DO NOT use other colors in the yellow color field.
107 107
107
2C.23LEHIGH UNIVERSITY | Wayfinding and Signage Manual
No Smokingwithin 25ftof Building
5
6
10 P1
9 P1P1
V2
P2
10
9 P1
P1
V2
Scale: 3" = 1'-0"Front Elevation
1
Scale: 3" = 1'-0"Side Elevation
2
1"1
1 /2"
11 1
/2"
1'-0"
1'-2
"
1"
1/4"
3/4"
A few guidelines to consider when selecting this sign type.
Program and locate this sign type near building entrances when vinyl messages at the door entrance cannot be utilized.
Place signs in areas where smoking could occur within 25ft of a building.
Minimize sign clutter by placing signage 300ft apart if multiple signs are required.
5- Stud MountSign panel/letterforms to be drilled and tapped to receive threaded studs. Drill wall and set with clear epoxy.
6- Spacer1/2" aluminum spacer.
9- Back Plate3/4" thick aluminum milled to shape shown. Paint all exposed surfaces.
10- Sign Panel3/8" thick aluminum sheet with surface applied graphics. Paint all exposed surfaces
BID.8 - Building Identification: Wall Mounted No SmokingGENERAL FABRICATION/GRAPHIC NOTES Field verification of each sign location and site conditions will be required prior to fabrication.
SECTION 2C | SIGN TYPE DRAWINGS BID.8
2C.24LEHIGH UNIVERSITY | Wayfinding and Signage Manual
No Smokingwithin 25ftof Building
Scale: 3" = 1'-0"
Programming Note: No two signs should be closer than 300 feet and no more than 2 signs per building to avoid sign clutter.
Graphic Layout 21
T2
4"
5 1 /
4"2"
11/2
"11
/2"
1"
BID.8SECTION 2C | SIGN TYPE DRAWINGS
2C.25LEHIGH UNIVERSITY | Wayfinding and Signage Manual
DO NOT increase the yellow fields/proportions DO NOT use other colors in the yellow color field.
No Smokingwithin 25ftof Building
No Smokingwithin 25ftof Building
SECTION 2C | SIGN TYPE DRAWINGS BID.8