ANM2000 Network ManagementSystem
Northbound Interface (TL1)
Operation Manual
Version: A
Code: MN000000542
FiberHome Telecommunication Technologies Co., Ltd.
October 2010
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
2/172
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
3/172
Thank you for choosing our products.
We appreciate your business. Your satisfaction is our
goal. We will provide you with comprehensive technical
support and after-sales service. Please contact your
local sales representative, service representative or
distributor for any help needed at the contact information
shown below.
Fiberhome Telecommunication Technologies Co., Ltd.
Address: No. 5 Dongxin Rd., Hongshan Dist., Wuhan, China
Zip code: 430073
Tel: +86-27-87691549
Fax: +86-27-87691755
Website: http://www.fiberhomegroup.com
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
4/172
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
5/172
Legal Notice
are trademarks of FiberHome Telecommunication Technologies Co., Ltd.(Hereinafter referred to as FiberHome)
All brand names and produc t names used in th is document are used for
identification purposes only and are trademarks or registered trademarks
of their respective holders.
Al l r ights reserved
No part of this document (including the electronic version) may be
reproduced or transmitted in any form or by any means without prior
written permission from FiberHome.
Information in this document is subject to change without notice.
TM
TMTM
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
6/172
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
7/172
I
Preface
As a commonly used access network management protocol, TL1 (TransactionLanguage 1) has been widely used on the FiberHome access platforms. Thismanual introduces the application range and operation methods of the TL1interface on the FiberHome EPON equipment.
Relevant Manuals
Manual Description
e-Fim ANM2000Broadband AccessNetwork ManagementSystemInstallation Manual(Based on Windows)
Describes the installation methods of the ANM2000.
e-Fim ANM2000Broadband AccessNetwork ManagementSystemOperation Manual(Based on Windows)
Describes the ANM2000 common operations and maintenancemethods for the purpose of helping users know the ANM2000further and operate it well.
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
8/172
II
Version and Usage
Version Instruction
A The initial version.
Intended Readers
This manual is intended for the following readers:
Planning and designing engineers
Commissioning engineers
Operation and maintenance engineers
To utilize this manual, these prerequisite skills are necessary:
Data communication technologies
Access network technologies
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
9/172
III
Conventions
Terminology Conventions
Terminology Meaning
ANM2000FiberHome e-Fim ANM2000 Broadband Access NetworkManagement System
Symbol Conventions
Symbol Refer to Meaning
Note Important features or operation guide.
CautionPossible injury to persons or systems, or cause trafficinterruption or loss.
Warning May cause severe bodily injuries.
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
10/172
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
11/172
V
Operation Safety Rules
Network management computer should be placed away fromdirect sunlight, electromagnetic interference, heat source,humidity and dust, and with at least 8 cm distance from otherobjects in order to keep good ventilation.
Use UPS power supply to avoid loss of network managementdata caused by accidental power failure.
To shut down the network management computer, first exit theoperating system normally and then shut off the power supply.
The computer crust, UPS power supply and switch (or hub)should be connected to protection earth ground.
Do not visit Internet via the network management computer withthe ANM2000. Otherwise, it may increase data flow in the net
card and hence affects normal network management datatransmission or results in other accidents.
No access to Internet !
S/OS
Figure 1 No access to Interne
To exit the ANM2000 normally does not make equipment out ofcontrol of the network management system.
Use of unidentified memory devices should be prohibited so asto avoid computer virus.
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
12/172
VI
Do not delete any file in the network management systemrandomly or copy any irrelevant file into the networkmanagement computer.
Do not perform service configuration or expansion in servicerush hours via network management system.
Network management computer cannot be used for purposesother than network management. Do not modify networkmanagement computers protocol setting, computer name or
LAN setting randomly. Otherwise, it may result in abnormaloperation of network management system.
Figure 2 Not permitted to modify protocol setting randomly (1)
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
13/172
VII
Figure 3 Not permitted to modify protocol setting randomly (2)
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
14/172
VIII
Figure 4 Not permitted to modify computer name randomly
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
15/172
IX
Figure 5 Not permitted to modify LAN setting randomly
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
16/172
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
17/172
Contents
Preface .................................................................................................................... I
Relevant Manuals .............................................................................. I
Version and Usage ............................................................................ II
Intended Readers ............................................................................. II
Conventions ..................................................................................... III
Operation Safety Rules .......................................................................................... V
1
Overview ...................................................................................................... 1-1
1.1 Service Provisioning Interface ........................................................ 1-2
1.2
Integrated Test Interface ................................................................ 1-4
1.3
Integrated Alarm Interface .............................................................. 1-6
1.4
Resource Query Interface .............................................................. 1-8
2
Interface Format ........................................................................................... 2-1
2.1 Format Overview ............................................................................ 2-2
2.2 Input Command Message Format .................................................. 2-3
2.3 Acknowledgement Message .......................................................... 2-4
2.4
Response Message Format ........................................................... 2-5
2.5
Definition of Returned Error Codes ................................................ 2-7
3 TL1 Commands ............................................................................................ 3-1
3.1
Session Control .............................................................................. 3-2
3.1.1
Logging in PON EMS (LOGIN) ........................................ 3-2
3.1.2
Logging out PON EMS (LOGOUT) .................................. 3-3
3.1.3 Handshaking Command (SHAKEHAND) ......................... 3-4
3.2 Integrated Test Interface ................................................................ 3-6
3.2.1
PON Service .................................................................. 3-27
3.2.2
Voice Service ................................................................. 3-47
3.2.3 LAN Service ................................................................... 3-66
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
18/172
ANM2000 Network Management System Northbound Interface (TL1) Operation Manual
1-2 Version: A
3.2.4 IPTV Service .................................................................. 3-71
3.2.5
Alarms ........................................................................... 3-73
3.2.6
VLAN Function............................................................... 3-73
3.3
Integrated Alarm Interface ............................................................ 3-76
3.3.1 Subscribing to Alarms (SUBSCRIBE) ............................ 3-76
3.3.2 Enabling the Alarm Filtering Function
(ACT-ALARM-FILTER) .................................................. 3-77
3.3.3
Disabling the Alarm Filtering Function
(DACT-ALARM-FILTER) ................................................ 3-78
3.3.4
Modifying the Alarm Filtering Configuration
(CHG-ALARM-FILTER).................................................. 3-79
3.3.5 Querying the Current Alarm Filtering Configuration
(LST-ALARM-FILTER) ................................................... 3-81
3.3.6 Obtaining Alarms (LST-ALARM) .................................... 3-82
3.3.7
Acknowledging an Alarm (ACK-ALARM) ....................... 3-85
3.3.8
Cancelling an Alarm Acknowledgement (UNACK-ALARM)
3-86
3.3.9 Clearing an Alarm (CLR-ALARM) .................................. 3-87
3.4 Resource Query Interface ............................................................ 3-89
3.4.1 Querying the OLT Equipment Information ...................... 3-89
3.4.2
Querying the ONU Equipment Information .................... 3-91
3.4.3
Querying the Subrack Information ................................. 3-94
3.4.4
Querying the Card Information....................................... 3-97
3.4.5
Querying the Media Gateway Information ................... 3-101
3.4.6 Querying the Voice Port Information ............................ 3-103
3.4.7 Querying the Multicast Service Information ................. 3-105
3.4.8 Querying the DSL Port InformationErro! Indicador no
definido.
3.4.9
Querying the LAN Port Information .............................. 3-107
3.4.10
Querying the Port VLAN Information ............................ 3-111
3.4.11 Subscribing to the Resource Change Notification........ 3-113
3.4.12 Unsubscribing to the Resource Change Notification.... 3-114
3.4.13 Querying the Resource Change Notification ................ 3-116
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
19/172
1 Overview
Version: A 1-3
3.4.14 Reporting the Resource Change Notification ............... 3-118
3.4.15
Exporting the Entire Network Resource Information .... 3-120
3.4.16
Querying the Resource Change Notification ................ 3-121
Appendix A The List of Alarms ............................................................................. 1
Appendix B The List of Parameters ..................................................................... 1
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
20/172
ANM2000 Network Management System Northbound Interface (TL1) Operation Manual
1-4 Version: A
Figures
Figure 1-1 The overall architecture of the PON IT support system ................... 1-2
Figure 1-2 The overall architecture of the PON integrated test system............. 1-4
Figure 1-3 The overall architecture of the PON integrated alarm system ......... 1-6
Figure 1-4 The overall architecture of the PON resource query system ........... 1-9
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
21/172
Version: A 1-1
1 Overview
This chapter introduces four types of northbound interfaces of the ANM2000, and
includes the following sections.
Service provisioning interface
Integrated test interface
Integrated alarm interface
Resource query interface
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
22/172
ANM2000 Network Management System Northbound Interface (TL1) Operation Manual
1-2 Version: A
1.1 Service Provisioning Interface
The automatic activation system receives the FTTx service activation workorder
from the upper level service provisioning system, splits the workorder, and then
maps the sub-task into the detailed NE configuration commands. By accessing the
PON EMS service provisioning interface and relevant FTTx product platforms /
NEs (such as the AAA authentication system, the softswitch, the SHLR, the IPTV
management platform, etc.), the system delivers various NE configurationcommands, so as to implement the automatic activation of the FTTx service.
The overall architecture of the PON service provisioning system is shown in the
following figure:
Service guarantee system
CRM system
Resource
management
system
Service
provision
system
Automaticactivation
system
PON
EMS
Service guarantee
system (module)
Construction
scheduling
system
(module)
Integrated test
system
(module)
Softswitch
AAAauthentication
system
Integrated
alarm
system
Client
HGU
Customer service
system
Optical
distributionnetwork
integrated
measurement
system
Client
Fault
complaint
Service
accept
Accounting
system
SHLR
IPTVmanagement
platform
BSS
domain
OSS
domain
----I1 interface
----I3 in terface
----I2 interf ace
----I4 interface
ITMS
OLT
MDU / SFU
----I5 interfac e
Figure 1-1 The overall architecture of the PON IT support system
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
23/172
1 Overview
Version: A 1-3
As Figure 1-1 shows, the systems involved with the FTTx service provisioning flow
include: the CRM system, the billing system, the service provisioning system, the
automatic activation system, the resource management system, the construction
scheduling system, the integrated test system, the PON EMS system, the AAA
authentication system, the softswitch system, the SHLR system, the IPTV
management platform.
The related interface is described as follows:
The I1 interface: the PON EMS northbound interface, providing the service
automatic activation function.
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
24/172
ANM2000 Network Management System Northbound Interface (TL1) Operation Manual
1-4 Version: A
1.2 Integrated Test Interface
The integrated test system implements the tests of the following aspects: the
troubleshooting of the PON, the routine monitor, the provisioning and completion
test of the PON. It initiates the test of the PON access network, and implements
the network fault reason diagnosis or network quality active monitor of the
equipment and the line by accessing the PON EMS integrated test interface or the
PON integrated measurement system.
The overall architecture of the PON integrated test system is shown in the
following figure:
Service guarantee system
CRM system
Resource
management
system
Service
provision
system
Automaticactivation
system
PON
EMS
Service guarantee
system (module)
Construction
scheduling
system
(module)
Integrated test
system
(module)
Softswitch
AAA
authenticationsystem
Integrated
alarm
system
Client
HGU
Customer service
system
Optical
distribution
network
integrated
measurement
system
Client
Fault
complaint
Service
accept
Accounting
system
SHLR
IPTV
managementplatform
BSS
domain
OSS
domain
----I1 interface
----I3 interface
----I2 interface
----I4 interface
ITMS
OLT
MDU / SFU
----I5 interface
Figure 1-2 The overall architecture of the PON integrated test system
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
25/172
1 Overview
Version: A 1-5
As Figure 1-2 shows, the systems involved with the FTTx integrated test include:
the customer service system, the service guarantee system, the resource
management system, the construction scheduling system, the integrated test
system, the PON EMS system, the PON integrated test system, etc.
The related interfaces are described as follows:
The I3 interface: the PON EMS northbound interface, providing the service fault
diagnosis and routine monitor functions.
The I2 interface: the PON EMS alarm report interface, completing the NE
equipment alarm report functions.
The I4 interface: the northbound interface of the PON integrated test system, used
to isolate and test various faults caused by the passive equipment (including the
optical fiber, the optical cable, the splitter, etc.) in the ODN rapidly and effectively.
In general, the FTTX integrated test system can perform the following threefunctions: the troubleshooting of the PON, the routine monitor of the PON, and the
provisioning and completion test of the PON.
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
26/172
ANM2000 Network Management System Northbound Interface (TL1) Operation Manual
1-6 Version: A
1.3 Integrated Alarm Interface
The northbound interface between the PON EMS and the integrated alarm system
reports the severe alarms influencing multiple subscribers in a batch manner. The
PON EMS reports the following alarms via this interface: various major alarms at
the network level (the MDU and the equipment of higher level), including hardware
faults alarms (such as the faults of the OLT equipment card and the power supply
module), severe alarms of the MDU software and hardware, abnormal power-offalarms, trunk fiber breakout alarms, and the MDU environment parameters and
relevant alarms in the FTTB mode.
The overall architecture of the PON integrated alarm system is shown in the
following figure:
Service guarantee system
CRM system
Resource
management
system
Service
provision
system
Automaticactivation
system
PON
EMS
Service guarantee
system (module)
Construction
scheduling
system
(module)
Integrated test
system
(module)
Softswitch
AAAauthentication
system
Integrated
alarm
system
Client
HGU
Customer service
system
Optical
distributionnetwork
integrated
measurement
system
Client
Fault
complaint
Service
accept
Accounting
system
SHLR
IPTV
management
platform
BSS
domain
OSS
domain
----I1 interface
----I3 interface
----I2 interface
----I4 interface
ITMS
OLT
MDU / SFU
----I5 interface
Figure 1-3 The overall architecture of the PON integrated alarm system
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
27/172
1 Overview
Version: A 1-7
As part of the service guarantee IT system, the integrated alarm system is the
convergence center of the monitored alarms and events. It performs the following
functions:
Alarm collection function: In PON, the system can collect severe alarms that
influence multiple subscribers in a batch manner and environment alarms on
the PON equipment via the alarm northbound interface of the PON EMS; can
initiate the alarm synchronization with the PON EMS system, so as to
implement the completeness of alarms.
Alarm handling function: In PON, the system can compress the PON alarmsaccording to the alarm compression rules configured by the operation and
maintenance division; can provide the detailed alarm information via the
association between the alarms and resources information (by analyzing the
association relationship between the alarms and resources information,
obtains the association relationship between the alarms and the services /
subscribers, and obtains the source and result relationships between alarms);
can deliver the workorder to the service guarantee system automatically
according to the workorder delivering rules.
Alarm operation function: In PON, users can confirm alarms, confirm deleting
alarms, and clear alarms; in addition, users can directly confirm, delete, and
clear the alarms in the PON EMS via the PON EMS alarm northbound
interface.
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
28/172
ANM2000 Network Management System Northbound Interface (TL1) Operation Manual
1-8 Version: A
1.4 Resource Query Interface
The PON EMS northbound interface performs the following resource query
functions: Exports all resource data in PON, queries the network resource data in
PON, and reports the changing condition of the network resource; among them,
exporting all resource data in PON is implemented via the file and the FTP, and
querying the network resource data in PON and reporting the changing condition
of the network resource are implemented via the TL1 protocol.
Users can query the following resource data via the PON EMS northbound
interface: the PON physical resource data, the service resource data, etc. The
OSS system can synchronize and check the data via the PON EMS northbound
interface, so as to keep the consistency between the OSS system data and the
PON EMS data.
The overall architecture of the PON resource query system is shown in the
following figure:
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
29/172
1 Overview
Version: A 1-9
Service guarantee system
CRM system
Resource
management
system
Service
provision
system
Automatic
activationsystem
PON
EMS
Service guarantee
system (module)
Construction
scheduling
system
(module)
Integrated test
system(module)
Softswitch
AAAauthentication
system
Integrated
alarmsystem
Client
HGU
Customer service
system
Optical
distribution
network
integrated
measurement
system
Client
Fault
complaint
Service
accept
Accounting
system
SHLR
IPTV
management
platform
BSS
domain
OSS
domain
----I1 interface
----I3 interface
----I2 interface
----I4 interface
ITMS
OLT
MDU / SFU
----I5 interface
Figure 1-4 The overall architecture of the PON resource query system
As Figure 1-4 shows, the OSS systems involved with the PON EMS resource
query include: the service guarantee system, the resource management system,
etc.
The related interface is described as follows:
The I5 interface: the PON EMS northbound interface, providing the resource data
query and resource changing notification functions.
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
30/172
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
31/172
Version: A 2-1
2 Interface Format
This chapter introduces the command format of the TL1 interface, and includesthe following sections.
Format overview
Input command message format
Acknowledgement message
Response message format
Definition of returned error codes
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
32/172
ANM2000 Network Management System Northbound Interface (TL1) Operation Manual
2-2 Version: A
2.1 Format Overview
Command format
Refers to the format for a user to input a command. The matching mode toexecute a command includes the following conditions:
Execute an operational command: All character strings are matched exactly.
Execute a query command: For an optional parameter whose data type ischaracter string, users can execute the fuzzy query; for a compulsoryparameter whose data type is character string, users should execute theexact matching. If the filtering conditions set by a user cannot identify aunique record, and there are multiple records complying with the filteringconditions, the northbound interface will return all records to the user in a list.
Response format
Refers to the format of the information which is returned to users. A correspondingcommand input is required to bring up an expected response.
Remarks
For descriptions on symbols used in various formats, please see the followingtable.
Symbol Description
< >Encloses a certain identifier symbol. For example, canindicate a random integer.
[ ] Encloses a certain optional symbol or message entry.
' 'Encloses a certain identifier letter. For example, a' indicates theEnglish letter a, instead of a variable symbol.
( ) Encloses a group of compulsory symbols or message entries.
*Refers to the postfix, indicating that the current symbol or symbol groupappears 0 or multiple times.
+Refers to the postfix, indicating that the current symbol or symbol groupappears once or multiple times.
^ Refers to a space.
cr Refers to a carriage return operation.
lf Refers to a line feed operation.
|Is used to separate multiple options, indicating that users can selectonly one option. For example, a|b|c indicates to select a or b or c.
::=In a certain syntax rule, separate the left and right parts. For example, ::= (0|1|-|9) indicates that the value of is a certaindigital number from 0 to 9 (including 0 and 9).
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
33/172
2 Interface Format
Version: A 2-3
2.2 Input Command Message Format
Input command message format
: : ;: : =[ - [ - ] ]Stagi ng Par ameter Bl ock: : =[ ] : : :
Remark
The following table describes various parameters of the command:
Parameter Remark
command_code
Refers to the codes of a command, indicating the operations to beperformed. Commonly this parameter complies with the followingformat:[-[-]]verb: Is a compulsory parameter, indicating the command name.Usually it is a verb or abbreviation describing the operation type.modifier: Is used to modify the input command . A verb can include twooptional modifiers, seperated with -.
staging_blocks
Refers to the task identifier block. Commonly this parameter complieswith the following format:[]:::target identifier: It is not needed here.access identifier: Refers to the identity information, used to identify theoperation object of the command.ctag (correlation tag): Refers to the command identifier code, used tomatch the input and output commands. In the response meassage andthe input message, this value should be the same.
payload_blocks
Refers to the transferring parameter block, and can be null. Commonlythis parameter complies with the following format:
, Among them, each parameter block (datablock) has the followingformat: parameter name = parameter value, and two parameter blocksare seperated with ,.
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
34/172
ANM2000 Network Management System Northbound Interface (TL1) Operation Manual
2-4 Version: A
2.3 Acknowledgement Message
The format of theacknowledgement message is described as follows:
acknowl edgment_code ct ag)
Response format of query commands:
[ ] header : : = ^ - - : : r esponse_i d: : =M r esponse_bl ock: : =( ( ^ ^ ) | ( ^ ) )quot ed l i ne: : = ^ ^
r esul t : : =( *) ( ( ( ) *) )( *) att r i bs: : =( ( ) *) val ues: : =( ( ) *) t ermi nat or: : =( ; | >)
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
36/172
ANM2000 Network Management System Northbound Interface (TL1) Operation Manual
2-6 Version: A
Remark
For the remarks in the command response result, please see the following table.
Parameter Remark
header
Refers to the message header, meaning the public parts of allresponse and report messages. It includes the equipment ID (sid),date, and time, and commonly complies with the following format:^^^^--^::sid: abbreviation of the manufacturer name _network mangementserver IP address. For exmple, it can be one of the following items:
HW_IPZTE_IPFH_IP
response_id
Refers to the response ID, and commonly complies with thefollowing format:M^^^Ctag: Refers to the command ID, used to match the input andoutput commands. In the response meassage and the inputmessage, this value should be the same.completion code: Refers to the response completion ID, with itsrange as follows:COMPLD: The command is executed correctly.DELAY: The command execution is delayed.DENY: The command execution fails.PRTL: The command is executed partially.RTRV: Returns the results of the executed tests in the command,and other test items are being performed.
response_block
Refers to the contents of the response message.EN: Refers to the error code.ENDESC: Refers to the description of an error.quoted line: Refers to the returned parameters. When the queriedinformation includes too many data, the northbound interface willsend the queried data to the client end in packets.total_blocks indicates the total number of data packets,block_number indicates the serial No. of the current data packet,and block_records indicates how many data entries are in thecurrent data packet.title: Is a character string, meaning the title of the result.attrib: Is a character string, meaning the arribute name.value: Is a character string, meaning the arribute value. If it is notsupported, - will be returned.
terminator
Is indicated with > or ;.> indicates that the data sending is not completed, and there is anext packet to be received.
; indicates that the data sending is completed. There can be only
one ; in the returned data.
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
37/172
2 Interface Format
Version: A 2-7
2.5 Definit ion of Returned Error Codes
EN (Error - Code) Error Type ENDESC (Error -Descript ion)
IRNE INPUT resource does not exist
IANE INPUT the alarm does not exist
IMP INPUT missing parameter
IIPF INPUT invalid parameter format
IIPE INPUT input parameter error
DDNS DEVICE device may not support this operation
DDOF DEVICE device operation failed
DDB DEVICE device is busy
SENS SYSTEM EMS may not support this operation
SEOF SYSTEM EMS operation failed
EEEH EXCEPTION EMS exception happens
TUB TEST user is busy
TUT TEST user is testing
TTMB TEST test module is busy
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
38/172
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
39/172
Version: A 3-1
3 TL1 Commands
This chapter introduces the operation methods of various TL1 interfaces, andincludes the following sections.
Session control
Service provisioning interface
Integrated test interface
Integrated alarm interface
Resource query interface
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
40/172
ANM2000 Network Management System Northbound Interface (TL1) Operation Manual
3-2 Version: A
3.1 Session Control
The session control is used to manage the communication between the integratedtest system and the PON EMS, so as to prevent access of illegal users.
3.1.1 Logging in PON EMS (LOGIN)
Functions
After establishing the TCP connection successfully, a user can log in the PONEMS via this command. When logging in successfully, a user can delivernorthbound interface commands to operate the equipment.
Command format
LOGI N: : : CTAG: : UN=user - name, PWD=passwor d;
Response format
Complies with the response format of operational commands mentioned in Section2.4.
Input parameter
Parameter Name Data Type Value Range Remark
UN OCTET STRING SIZE (20) The username
PWD OCTET STRING SIZE (16) The password
Output parameter
None
Example
Command:
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
41/172
3 TL1 Commands
Version: A 3-3
LOGI N: : : CTAG: : UN=1, PWD=1;
Response:
FH_133. 5. 35. 238 2010- 05- 26 19: 23: 18M CTAG COMPLDEN=0 ENDESC=No er r or
Meaning:
The user has logged in successfully.
3.1.2 Logging out PON EMS (LOGOUT)
Functions
A user logs out the PON EMS.
Command format
LOGOUT: : : CTAG: : ;
Response format
Complies with the response format of operational commands mentioned in Section2.4.
Input parameter
None
Output parameter
None
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
42/172
ANM2000 Network Management System Northbound Interface (TL1) Operation Manual
3-4 Version: A
Example
Command:
LOGOUT: : : CTAG: : ;
Response:
FH_133. 5. 35. 238 2010- 05- 26 19: 23: 23M CTAG COMPLD
EN=0 ENDESC=No er r or
Meaning:
The user has logged out successfully.
3.1.3 Handshaking Command (SHAKEHAND)
Functions
If there are no communications on a certain TCP connection in a 10-minuteinterval, the system will disconnect this TCP connection automatically. To maintainthis connection without any other operation, users can deliver a handshakingcommand.
Command format
SHAKEHAND: : : CTAG: : ;
Response format
Complies with the response format of operational commands mentioned in Section2.4.
Input parameter
None
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
43/172
3 TL1 Commands
Version: A 3-5
Output parameter
None
Example
Command:
SHAKEHAND: : : CTAG: : ;
Response:
FH_133. 5. 35. 238 2010- 05- 26 19: 23: 20M CTAG COMPLDEN=0 ENDESC=No er r or
Meaning:
The user has handshaked successfully.
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
44/172
ANM2000 Network Management System Northbound Interface (TL1) Operation Manual
3-6 Version: A
3.2 Service Provisioning Interface
3.2.1 Act ivating a VoIP Port
Functions
This command is used to activate a VoIP port.
Command format
ACT- VOI PPORT: : ONUI P=onu- name| [ OLTI D=ol t - name, PONI D=ponport _l ocat i on, ONUI DTYPE=onui d- t ype, ONUI D=onu- i ndex] , ONUPORT=onu- port : CTAG: : ;
Response format
Complies with the response format mentioned in Section2.4.
Input parameter
ParameterName
Data Type Value Range Remark
ONUIPOCTETSTRING
SIZE (128)The IP address, name, or ID of an ONU withthe management IP address
OLTIDOCTETSTRING
SIZE (128) The IP address, name, or ID of an OLT
PONIDOCTETSTRING
SIZE (128)cabinet-subrack-slot-PON port No.
The PON port identity information. A PONport is identified by the cabinet-subrack-slot-PON port No. In the absence ofany of the cabinet, subrack, slot, PON portNo., fill with NA.
ONUIDTYPEOCTETSTRING
SIZE (128) The ONU ID TYPE (MAC, LOID)
ONUID OCTETSTRING
SIZE (128)
cabinet-subrack-slot-port No.
The ONU ID, and its value can be one of the
following four items: MAC, LOID. It is used touniquely identify an ONU connected with theappointed PON port.
ONUPORTOCTETSTRING
A card port is identified by the cabinet-subrack-slot-port No., and in the absence ofany of the cabinet, subrack, slot, PON portNo., fill with NA.
[g1] Comentrio: GPON
,
,
3.2.8,3.2.9,3.2.10,3.2.11.3.2.3.3.2.4
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
45/172
3 TL1 Commands
Version: A 3-7
Example
Command:
ACT- VOI PPORT: : OLTI D=133. 5. 35. 235, PONI D=NA- NA- 4- 4, ONUI DTYPE=MAC, ONUI D=54- 5B- 04- B3- 43- A0, ONUPORT=NA- NA- NA- 1: CTAG: : ;
Response:
FH_133. 5. 35. 238 2010- 05- 22 18: 00: 37M CTAG COMPLDEN=0 ENDESC=No er r or
Meaning:
This command is used to activate the NA-NA-NA-1 VOIP port on the54-5B-04-B3-43-A0 ONU.
3.2.2 Deactivating a VoIP Port
Functions
This command is used to deactivate a VoIP port.
Command format
DACT- VOI PPORT: : ONUI P=onu- name| [ OLTI D=ol t - name, PONI D=ponport _l ocat i on,ONUI DTYPE=onui d- t ype, ONUI D=onu- i ndex] , ONUPORT=onu- port : CTAG: : ;
Response format
Complies with the response format mentioned in Section2.4.
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
46/172
ANM2000 Network Management System Northbound Interface (TL1) Operation Manual
3-8 Version: A
Parameters
Parameter Name Data Type Value Range Remark
ONUIP OCTET STRING SIZE (128)The IP address, name, or IDof an ONU with themanagement IP address
OLTID OCTET STRING SIZE (128)The IP address, name, or IDof an OLT
PONID OCTET STRING
SIZE (128)cabinet-subrack-slot-PONport No.
The PON port identityinformation. A PON port isidentified by the cabinet-subrack-slot-PON port No.,and in the absence of any ofthe cabinet, subrack, slot,
PON port No., fill with NA.
ONUIDTYPE OCTET STRING SIZE (128)The ONU ID TYPE (MAC,LOID)
ONUID OCTET STRING SIZE (128)
The ONU ID, and its valuecan be one of the followingfour items: MAC, LOID. It isused to uniquely identify anONU connected with theappointed PON port.
ONUPORT OCTET STRING
SIZE (128)cabinet-subrack-slot- portNo.
A card port is identified bythe cabinet-subrack-slot-port No., andin the absence of any of thecabinet, subrack, slot, PONport No., fill with NA.
Example
Command:
DACT- VOI PPORT: : OLTI D=133. 5. 35. 235, PONI D=NA- NA- 4- 4, ONUI DTYPE=MAC, ONUI D=54-5B- 04- B3- 43- A0, ONUPORT=NA- NA- NA- 1: CTAG: : ;
Response:
FH_133. 5. 35. 238 2010- 05- 23 10: 31: 22M CTAG COMPLDEN=0 ENDESC=No er r or
Meaning:
This command is used to deactivate the NA-NA-NA-1 VOIP port on the54-5B-04-B3-43-A0 ONU.
3.2.3 Configuring the Voice Service of a VoIP Port
Functions
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
47/172
3 TL1 Commands
Version: A 3-9
This command is used to configure the voice service of a VoIP port.
Command format
CFG- VOI PSERVI CE: : ONUI P=onu- name| [ OLTI D=ol t - name, PONI D=ponport _l ocat i on, ONUI DTYPE=onui d- t ype, ONUI D=onu- i ndex], ONUPORT=onu-por t : CTAG: : [ PHONENUMBER=phone number, ] PT=prot ocol t ype[ , SLVAN=voi p outervl an] [ , VOI PVLAN=voi p i nnervl an] [ , SCOS=out er - qos] [ , CCOS=i nnerqos] [ , EI D=equi pment - i d] [ TI D=Ter mi nal- I D] [ SI PREGDM=si p r egi st er domai n, SI PUSERNAME=si p- user-name] [ , SI PUSERPWD=si puser password] [ MGCI P1=act i ve baci p] [ , MGCI P2=st andby bac i p] [ , I PMODE=i p mode] [ , I P=i paddr ess, I PMASK=i p- mask, I PGATEWAY=i p- gateway] [ , PPPOEUSER=pppoe- user ,
PPPOEPWD=pppoe passwor d] ;
Response format
Complies with the response format mentioned in Section2.4.
Parameters
Parameter Name Data Type Value Range Remark
ONUIP OCTET STRING SIZE (128)The IP address, name, orID of an ONU with the
management IP address
OLTID OCTET STRING SIZE (128)The IP address, name, orID of an OLT
PONID OCTET STRING
SIZE (128)cabinet-subrack-slot-PONport No.
The PON port identityinformation. A PON port isidentified by the cabinet-subrack-slot-PON portNo., and in the absence ofany of the cabinet,subrack, slot, PON portNo., fill with NA..
ONUIDTYPE OCTET STRING SIZE (128)The ONU ID TYPE (MAC,LOID)
ONUID OCTET STRING SIZE (128)
The ONU ID, and its valuecan be one of the followingfour items: MAC, LOID. It isused to uniquely identify an
ONU connected with theappointed PON port.
ONUPORT OCTET STRING
SIZE (128)cabinet-subrack-slot- portNo.
A card port is identified bythe cabinet-subrack-slot-port No., andin the absence of any ofthe cabinet, subrack, slot,PON port No., fill with NA..
PHONENUMBER OCTET STRING SIZE (1 to 32) The telephone number
PT OCTET STRING SIZE (1 to 32)The voice protocol type(H.248, SIP)
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
48/172
ANM2000 Network Management System Northbound Interface (TL1) Operation Manual
3-10 Version: A
Parameter Name Data Type Value Range Remark
EID OCTET STRING SIZE (1 to 64)The MG gateway domainname in the H.248 protocolconfiguration
TID OCTET STRING SIZE (1 to 64)The H.248 subscriberterminal ID
SIPREGDM OCTET STRING SIZE (1 to 32) The SIP register server
SIPUSERNAME OCTET STRING SIZE (1 to 32)The usernamecorresponding to the SIPsubscriber port
SIPUSERPWD OCTET STRING SIZE (1 to 32)The passwordcorresponding to the SIPsubscriber port
SVLAN INTEGER 0 to 4095The voice service outerVLAN
VOIPVLAN INTEGER 0 to 4095 The voice service innerVLAN
IPMODE OCTET STRING SIZE (1 to 32)The IP obtaining mode:DHCP, PPPoE, static
IP OCTET STRING SIZE (1 to 32) The IP address
IPMASK OCTET STRING SIZE (1 to 32) The IP address mask
IPGATEWAY OCTET STRING SIZE (1 to 32) The gateway address
PPPOEUSER OCTET STRING SIZE (1 to 32) The PPPoE username
PPPOEPWD OCTET STRING SIZE (1 to 32) The PPPoE password
SCOS INTEGER 0 to 7 The outer service priority
CCOS INTEGER 0 to 7 The inner service priority
MGCIP1 OCTET STRING SIZE (32)The active softswitch IPaddress
MGCIP2 OCTET STRING SIZE (32)The standby softswitch IP
address
Example
Command:
CFG- VOI PSERVI CE: : OLTI D=133. 5. 35. 235, PONI D=NA-NA-4- 4, ONUI DTYPE=MAC, ONUID=54- 5B- 04- B3- 43- A0, ONUPORT=NA- NA- NA- 1: CTAG: : PHONENUMBER=77777777, PT=H. 248, VOI PVLAN=650, CCOS=0, EI D=ei d, TI D=t i d, I PMODE=STATI C, I P=14. 14. 14. 7, IPMASK=255. 255. 0. 0, I PGATEWAY=14. 14. 14. 1;
Response:
FH_133. 5. 35. 238 2010- 05- 23 10: 31: 22M CTAG COMPLDEN=0 ENDESC=No er r or
This command is used to configure the voice service of the 54-5B-04-B3-43-A0ONU VoIP port on the 133.5.35.235 OLT.
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
49/172
3 TL1 Commands
Version: A 3-11
3.2.4 Deleting the Voice Service of a VoIP Port
Functions
This command is used to delete configure the voice service of a VoIP port.
Command format
DEL- VOI PSERVI CE: : ONUI P=onu- name| [ OLTI D=ol t - name, PONI D=ponport _l ocat i on
, ONUI DTYPE=onui d- t ype, ONUI D=onu- i ndex] , ONUPORT=onu- port : CTAG: : ;
Response format
Complies with the response format mentioned in Section2.4.
Parameters
Parameter Name Data Type Value Range Remark
ONUIP OCTET STRING SIZE (128)The IP address, name, orID of an ONU with the
management IP address
OLTID OCTET STRING SIZE (128)The IP address, name, orID of an OLT
PONID OCTET STRING
SIZE (128)cabinet-subrack-slot-PONport No.
The PON port identityinformation. A PON port isidentified by the cabinet-subrack-slot-PON portNo., and in the absence ofany of the cabinet,subrack, slot, PON portNo., fill with NA..
ONUIDTYPE OCTET STRING SIZE (128)The ONU ID TYPE (MAC,LOID)
ONUID OCTET STRING SIZE (128)
The ONU ID, and its valuecan be one of the followingfour items: MAC, LOID. It isused to uniquely identify an
ONU connected with theappointed PON port.
ONUPORT OCTET STRING
SIZE (128)cabinet-subrack-slot- portNo.
A card port is identified bythe cabinet-subrack-slot-port No., andin the absence of any ofthe cabinet, subrack, slot,PON port No., fill with NA..
Example
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
50/172
ANM2000 Network Management System Northbound Interface (TL1) Operation Manual
3-12 Version: A
Command:
DEL- VOI PSERVI CE: : OLTI D=133. 5. 35. 235, PONI D=NA-NA-4- 4, ONUI DTYPE=MAC, ONUID=54- 5B- 04- B3- 43- A0, ONUPORT=NA-NA-NA-1: CTAG: : ;
Response:
FH_133. 5. 35. 238 2010- 05- 23 10: 31: 22M CTAG COMPLDEN=0 ENDESC=No er r or
This command is used to delete configure the voice service of the
54-5B-04-B3-43-A0 ONU VoIP port on the 133.5.35.235 OLT.
3.2.5 Activating a LAN Port
Functions
This command is used to activate a LAN port.
Command format
ACT- LANPORT: : ONUI P=onu- name| OLTI D=ol t - name[ , PONI D=ponport _l ocat i on,ONUI DTYPE=onui d- t ype, ONUI D=onu- i ndex] , ONUPORT=onu- port : CTAG: : ;
Response format
Complies with the response format mentioned in Section2.4.
Parameters
ParameterName
Data Type Value Range Remark
ONUIP OCTET STRING SIZE (128)The IP address, name, or ID of anONU with the management IPaddress
OLTID OCTET STRING SIZE (128)The IP address, name, or ID of anOLT
PONID OCTET STRING
SIZE (128)cabinet-subrack-slot-PONport No.
The PON port identity information. APON port is identified by the cabinet-subrack-slot-PON port No., and inthe absence of any of the cabinet,subrack, slot, PON port No., fill withNA..
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
51/172
3 TL1 Commands
Version: A 3-13
ParameterName
Data Type Value Range Remark
ONUIDTYPE
OCTET STRING SIZE (128) The ONU ID TYPE (MAC, LOID)
ONUID OCTET STRING SIZE (128)
The ONU ID, and its value can beone of the following four items:MAC, LOID. It is used to uniquelyidentify an ONU connected with theappointed PON port.
ONUPORT OCTET STRING
SIZE (128)cabinet-subrack-slot- portNo.
A card port is identified by thecabinet -subrack-slot-port No., andin the absence of any of the cabinet,subrack, slot, PON port No., fill withNA..
Example
Command:
ACT- LANPORT: : OLTI D=133. 5. 35. 235, PONI D=NA- NA- 4- 4, ONUI DTYPE=MAC, ONUI D=54- 5B- 04- B3- 43- A0, ONUPORT=NA- NA- NA- 1: CTAG: : ;
Response:
10. 22. 16. 22 2007- 03- 01 13: 35: 00M CTAG COMPLDEN=0 ENDESC=No er r or
Meaning:
This command is used to activate the NA-NA-NA-1 FE VOIP port on the54-5B-04-B3-43-A0 ONU.
3.2.6 Deactivating a LAN Port
Functions
This command is used to deactivate a LAN port.
Command format
DACT- LANPORT: : ONUI P=onu- name| OLTI D=ol t - name[ , PONI D=ponport _l ocat i on,ONUI DTYPE=onui d- t ype, ONUI D=onu- i ndex] , ONUPORT=onu- port : CTAG: : ;
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
52/172
ANM2000 Network Management System Northbound Interface (TL1) Operation Manual
3-14 Version: A
Response format
Complies with the response format mentioned in Section2.4.
Parameters
ParameterName
Data Type Value Range Remark
ONUIP OCTET STRING SIZE (128)The IP address, name, or ID of anONU with the management IPaddress
OLTID OCTET STRING SIZE (128) The IP address, name, or ID of anOLT
PONID OCTET STRING
SIZE (128)cabinet-subrack-slot-PONport No.
The PON port identity information. APON port is identified by the cabinet-subrack-slot-PON port No., and inthe absence of any of the cabinet,subrack, slot, PON port No., fill withNA.
ONUIDTYPE OCTET STRING SIZE (128) The ONU ID TYPE (MAC, LOID)
ONUID OCTET STRING SIZE (128)
The ONU ID, and its value can beone of the following four items:MAC, LOID. It is used to uniquelyidentify an ONU connected with theappointed PON port.
ONUPORT OCTET STRING
SIZE (128)cabinet
-subrack-slot- portNo.
A card port is identified by thecabinet -subrack-slot-port No., andin the absence of any of the cabinet,
subrack, slot, PON port No., fill withNA.
Example
Command:
DACT- LANPORT: : OLTI D=133. 5. 35. 235, PONI D=NA- NA- 4- 4, ONUI DTYPE=MAC, ONUI D=54- 5B- 04- B3- 43- A0, ONUPORT=NA- NA- NA- 1: CTAG: : ;
Response:
10. 22. 16. 22 2007- 03- 01 13: 35: 00M CTAG COMPLD
EN=0 ENDESC=No er r or
Meaning:
This command is used to deactivate the NA-NA-NA-1 FE VOIP port on the54-5B-04-B3-43-A0 ONU.
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
53/172
3 TL1 Commands
Version: A 3-15
3.2.7 Configuring the Bandwidth of a LAN Port
Functions
This command is used to configure the bandwidth of a LAN port.
Command format
CFG- LANPORT: : ONUI P=onu- name| OLTI D=ol t - name[ , PONI D=ponport _l ocat i on,
ONUI DTYPE=onui d- t ype, ONUI D=onu- i ndex], ONUPORT=onu-por t : CTAG: : BW=bandwi dt h;
Response format
Complies with the response format mentioned in Section2.4.
Parameters
ParameterName
Data Type Value Range Remark
ONUIP OCTET STRING SIZE (128)
The IP address, name, or ID of an ONU
with the management IP addressOLTID OCTET STRING SIZE (128) The IP address, name, or ID of an OLT
PONID OCTET STRING
SIZE (128)Cabinet-subrack-slot-PON port No.
The PON port identity information. APON port is identified by the cabinet-subrack-slot-PON port No., and in theabsence of any of the cabinet, subrack,slot, PON port No., fill with NA.
ONUIDTYPE OCTET STRING SIZE (128) The ONU ID TYPE (MAC, LOID)
ONUID OCTET STRING SIZE (128)
The ONU ID, and its value can be oneof the following four items: MAC, LOID.It is used to uniquely identify an ONUconnected with the appointed PONport.
ONUPORT OCTET STRING
SIZE (128)Cabinet-subrack-slot-
port No.
A card port is identified by the cabinet-subrack-slot-port No., and in theabsence of any of the cabinet, subrack,
slot, PON port No., fill with NA.BW OCTET STRING SIZE (128) The bandwidth profile name
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
54/172
ANM2000 Network Management System Northbound Interface (TL1) Operation Manual
3-16 Version: A
Example
Command:
CFG- LANPORT: : OLTI D=133. 5. 35. 235, PONI D=NA- NA- 4- 4, ONUI DTYPE=MAC, ONUI D=54- 5B-04- B3-43- A0, ONUPORT=NA- NA- NA- 1: CTAG: : BW=4M;
Response:
10. 22. 16. 22 2007- 03- 01 13: 35: 00M CTAG COMPLDEN=0 ENDESC=No er r or
Meaning:
This command is used to configure the bandwidth of the NA-NA-NA-1 LAN port ofthe 54-5B-04-B3-43-A0 ONU.
3.2.8 Adding a LAN Port into a Multicast Group
Functions
This command is used to add a LAN port into a multicast group.
Command format
ADD- LANI PTVPORT: : ONUI P=onu- name| OLTI D=ol t - name[ , PONI D=ponport _l ocat i on, ONUI DTYPE=onui d- t ype, ONUI D=onu- i ndex], ONUPORT=onu-por t : CTAG: : [ UV=uservl an] [ , MVLAN=mvl an] ;
Response format
Complies with the response format mentioned in Section2.4.
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
55/172
3 TL1 Commands
Version: A 3-17
Parameters
ParameterName
Data Type Value Range Remark
ONUIPOCTETSTRING
SIZE (128)The IP address, name, or ID of anONU with the management IPaddress
OLTIDOCTETSTRING
SIZE (128)The IP address, name, or ID of anOLT
PONIDOCTETSTRING
SIZE (128)Cabinet-subrack-slot-PONport No.
The PON port identity information. APON port is identified by the cabinet-subrack-slot-PON port No., and inthe absence of any of the cabinet,subrack, slot, PON port No., fill with
NA.ONUIDTYPE
OCTETSTRING
SIZE (128) The ONU ID TYPE (MAC, LOID)
ONUIDOCTETSTRING
SIZE (128)
The ONU ID, and its value can beone of the following four items:MAC, LOID. It is used to uniquelyidentify an ONU connected with theappointed PON port.
ONUPORTOCTETSTRING
SIZE (128)Cabinet-subrack-slot- portNo.
A card port is identified by thecabinet -subrack-slot-port No., andin the absence of any of the cabinet,subrack, slot, PON port No., fill withNA.
UV INTEGER 0 to 4095 The subscriber side VLAN
MVLAN INTEGER 0 to 4095 The related multicast VLAN
Example
Command:
ADD- LANI PTVPORT: : OLTI D=133. 5. 35. 235, PONI D=NA- NA- 4- 4, ONUI DTYPE=MAC, ONUID=54- 5B-04- B3-43- A0, ONUPORT=NA- NA- NA- 1: CTAG: : UV=100, MVLAN=88;
Response:
10. 22. 16. 22 2007- 03- 01 13: 35: 00M CTAG COMPLD
EN=0 ENDESC=No er r or
Meaning:
This command is used to add the NA-NA-NA-1 LAN port of the54-5B-04-B3-43-A0 ONU into a multicast group.
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
56/172
ANM2000 Network Management System Northbound Interface (TL1) Operation Manual
3-18 Version: A
3.2.9 Deleting a LAN Port f rom a Multicast Group
Functions
This command is used to delete a LAN port from a multicast group.
Command format
DEL- LANI PTVPORT: : ONUI P=onu- name| OLTI D=ol t - name[ , PONI D=ponport _l ocat i on
, ONUI DTYPE=onui d- t ype, ONUI D=onu- i ndex], ONUPORT=onu-por t : CTAG: : [ UV=uservl an] [ , MVLAN=mvl an] ;
Response format
Complies with the response format mentioned in Section2.4.
Parameters
ParameterName
Data Type Value Range Remark
ONUIP OCTET STRING SIZE (128)The IP address, name, or ID of anONU with the management IP
addressOLTID OCTET STRING SIZE (128)
The IP address, name, or ID of anOLT
PONID OCTET STRING
SIZE (128)Cabinet-subrack-slot-PONport No.
The PON port identity information. APON port is identified by the cabinet-subrack-slot-PON port No., and inthe absence of any of the cabinet,subrack, slot, PON port No., fill withNA.
ONUIDTYPE OCTET STRING SIZE (128) The ONU ID type (MAC, LOID)
ONUID OCTET STRING SIZE (128)
The ONU ID, and its value can beone of the following four items:MAC, LOID. It is used to uniquelyidentify an ONU connected with theappointed PON port.
ONUPORT OCTET STRING
SIZE (128)
Cabinet-subrack-slot- portNo.
A card port is identified by thecabinet -subrack-slot-port No., and
in the absence of any of the cabinet,subrack, slot, PON port No., fill withNA.
UV INTEGER 0 to 4095 The subscriber side VLAN
MVLAN INTEGER 0 to 4095 The related multicast VLAN
Example
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
57/172
3 TL1 Commands
Version: A 3-19
Command:
DEL- LANI PTVPORT: : OLTI D=133. 5. 35. 235, PONI D=NA- NA- 4- 4, ONUI DTYPE=MAC, ONUID=54- 5B-04- B3-43- A0, ONUPORT=NA- NA- NA- 1: CTAG: : UV=100, MVLAN=88;
Response:
10. 22. 16. 22 2007- 03- 01 13: 35: 00M CTAG COMPLDEN=0 ENDESC=No er r or
Meaning:
This command is used to delete the NA-NA-NA-1 LAN port of the54-5B-04-B3-43-A0 ONU from a multicast group.
3.2.9 Configuring the IPTV Service Information of a LANPort
Functions
This command is used to configure the IPTV service information of a LAN port.
Command format
CFG- LANI PTVPORT: : ONUI P=onu- name| OLTI D=ol t - name[ , PONI D=ponport _l ocat i on, ONUI DTYPE=onui d- t ype, ONUI D=onu- i ndex], ONUPORT=onu-por t : CTAG: : [ FLMODE=i ptv- f ast l eave-mode] [ , MAXGRP=Max-group- number ] ;
Response format
Complies with the response format mentioned in Section 2.4.
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
58/172
ANM2000 Network Management System Northbound Interface (TL1) Operation Manual
3-20 Version: A
Parameters
ParameterName
Data Type Value Range Remark
ONUIPOCTETSTRING
SIZE (128)The IP address, name, or ID of anONU with the management IPaddress
OLTIDOCTETSTRING
SIZE (128)The IP address, name, or ID of anOLT
PONIDOCTETSTRING
SIZE (128)Cabinet-subrack-slot-PONport No.
The PON port identity information. APON port is identified by the cabinet-subrack-slot-PON port No., and inthe absence of any of the cabinet,subrack, slot, PON port No., fill with
NA.ONUIDTYPE
OCTETSTRING
SIZE (128) The ONU ID type (MAC, LOID)
ONUIDOCTETSTRING
SIZE (128)
The ONU ID, and its value can be oneof the following four items: MAC,LOID. It is used to uniquely identify anONU connected with the appointedPON port.
ONUPORTOCTETSTRING
SIZE (128)Cabinet-subrack-slot- portNo.
A card port is identified by the cabinet-subrack-slot-port No., and in theabsence of any of the cabinet,subrack, slot, PON port No., fill withNA.
FLMODEOCTETSTRING
SIZE (32)The fast leave mode:EnabledDisabled
MAXGRP INTEGER 0 to 255
Means the maximum multicast
program number a port is allowed tojoin at a time.
Example
Command:
CFG- LANI PTVPORT: : OLTI D=133. 5. 35. 235, PONI D=NA- NA- 4- 4, ONUI DTYPE=MAC, ONUID=54- 5B-04- B3-43- A0, ONUPORT=NA- NA- NA- 1: CTAG: : FLMODE=1, MAXGRP=35;
Response:
10. 22. 16. 22 2007- 03- 01 13: 35: 00M CTAG COMPLD
EN=0 ENDESC=No er r or
Meaning:
This command is used to configure the IPTV service information of theNA-NA-NA-1 LAN port on the 54-5B-04-B3-43-A0 ONU.
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
59/172
3 TL1 Commands
Version: A 3-21
3.2.10 Configuring the VLAN Information of a LAN Port
Functions
This command is used to configure the VLAN information of a LAN port.
Command format
CFG- LANPORTVLAN: : ONUI P=onu-name| OLTI D=ol t - name[ , PONI D=ponpor t _l ocat i on, ONUI DTYPE=onui d- t ype, ONUI D=onu- i ndex], ONUPORT=onu-por t : CTAG: : [ SVLAN=o
uter vl an] , CVLAN=I nner vl an[ , UV=user vl an] [ , SCOS=out er qos] [ , CCOS=i nnerqos];
Response format
Complies with the response format mentioned in Section 2.4.
Parameters
ParameterName
Data Type Value Range Remark
ONUIPOCTETSTRING
SIZE (128)The IP address, name, or ID of anONU with the management IP
addressOLTID
OCTETSTRING
SIZE(128)The IP address, name, or ID of anOLT
PONIDOCTETSTRING
SIZE (128)Cabinet-subrack-slot-PONport No.
The PON port identity information. APON port is identified by the cabinet-subrack-slot-PON port No., and inthe absence of any of the cabinet,subrack, slot, PON port No., fill withNA.
ONUIDTYPEOCTETSTRING
SIZE(128) The ONU ID type (MAC, LOID)
ONUIDOCTETSTRING
SIZE(128)
The ONU ID, and its value can beone of the following four items:MAC, LOID. It is used to uniquelyidentify an ONU connected with theappointed PON port.
ONUPORT OCTETSTRING
SIZE (128)
Cabinet-subrack-slot- portNo.
A card port is identified by the
cabinet -subrack-slot-port No., andin the absence of any of the cabinet,subrack, slot, PON port No., fill withNA.
SVLAN INTEGER 0 to 4095 The SVLAN
CVLAN INTEGER 0 to 4095 The CVLAN
UV INTEGER 0 to 4095 The User VLAN
SCOS INTEGER 0 to 7The priority information carried bythe SVLAN
CCOS INTEGER 0 to 7The priority information carried bythe CVLAN
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
60/172
ANM2000 Network Management System Northbound Interface (TL1) Operation Manual
3-22 Version: A
Example
Command:
CFG- LANPORTVLAN: : OLTI D=133. 5. 35. 234, PONI D=NA- NA- 4- 1, ONUI DTYPE=MAC, ONUID=54- 5B-04- B3-43- A0, ONUPORT=NA- NA- NA- 1: CTAG: : SVLAN=510, CVLAN=1301, UV=487;
Response:
10. 22. 16. 22 2007- 03- 01 13: 35: 00M CTAG COMPLDEN=0 ENDESC=No er r or
Meaning:
This command is used to configure the VLAN information of the NA-NA-NA-1 LANport on the 54-5B-04-B3-43-A0 ONU.
3.2.11 Deleting the VLAN Information from a LAN Port
Functions
This command is used to delete the VLAN information from a LAN port on anFTTH ONU.
Command format
DEL- LANPORTVLAN: : ONUI P=onu-name| OLTI D=ol t - name[ , PONI D=ponpor t _l ocat i on, ONUI DTYPE=onui d- t ype, ONUI D=onu- i ndex], ONUPORT=onu-por t : CTAG: : [ UV=uservl an];
Response format
Complies with the response format mentioned in Section 2.4.
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
61/172
3 TL1 Commands
Version: A 3-23
Parameters
ParameterName
Data Type Value Range Remark
ONUIP OCTET STRING SIZE (128)The IP address, name, or ID of anONU with the management IPaddress
OLTID OCTET STRING SIZE (128)The IP address, name, or ID of anOLT
PONID OCTET STRING
SIZE (128)Cabinet-subrack-slot-PONport No.
The PON port identity information. APON port is identified by the cabinet-subrack-slot-PON port No., and inthe absence of any of the cabinet,subrack, slot, PON port No., fill with
NA.ONUIDTYPE OCTET STRING SIZE (128) The ONU ID type (MAC, LOID)
ONUID OCTET STRING SIZE (128)
The ONU ID, and its value can be oneof the following four items: MAC,LOID. It is used to uniquely identify anONU connected with the appointedPON port.
ONUPORT OCTET STRING
SIZE (128)Cabinet-subrack-slot- portNo.
A card port is identified by the cabinet-subrack-slot-port No., and in theabsence of any of the cabinet,subrack, slot, PON port No., fill withNA.
UV INTEGER 0 to 4095 The User VLAN
Example
Command:
DEL- LANPORTVLAN: : OLTI D=133. 5. 35. 234, PONI D=NA- NA- 4- 1, ONUI DTYPE=MAC, ONUID=54- 5B-04- B3-43- A0, ONUPORT=NA- NA- NA- 1: CTAG: : UV=487;
Response:
10. 22. 16. 22 2007- 03- 01 13: 35: 00M CTAG COMPLDEN=0 ENDESC=No er r or
Meaning:
This command is used to delete the VLAN information of the NA-NA-NA-1 LANport on the 54-5B-04-B3-43-A0 ONU.
3.2.12 Adding an ONU
Functions
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
62/172
ANM2000 Network Management System Northbound Interface (TL1) Operation Manual
3-24 Version: A
This command is used to add an ONU.
Command format
ADD- ONU: : OLTI D=ol t - name, PONI D=ponport _l ocat i on: CTAG: : [ AUTHTYPE=auth- t ype, ] ONUI D=onu- i ndex[ , NAME=name] , ONUTYPE=onu t ype;
Response format
Complies with the response format mentioned in Section 2.4.
Parameters
ParameterName
Data Type Value Range Remark
OLTID OCTET STRING SIZE (128)The IP address, name, or ID of anOLT
PONID OCTET STRING
SIZE (128)Cabinet-subrack-slot-PONport No.
The PON port identity information. APON port is identified by the cabinet-subrack-slot-PON port No., and inthe absence of any of the cabinet,subrack, slot, PON port No., fill withNA.
AUTHTYPE
OCTET STRING SIZE (128) ONU authorize type(MAC,LOID)
ONUID OCTET STRING SIZE (128) The ONU ID (LOID)
PWD OCTET STRING SIZE (128) The LOID passwordNAME OCTET STRING SIZE (128) The ONU name
ONUTYPE OCTET STRING SIZE (32) The ONU type
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
63/172
3 TL1 Commands
Version: A 3-25
Example
Command:
ADD- ONU: : OLTI D=133. 5. 35. 235, PONI D=NA- NA- 4- 4: CTAG: : AUTHTYPE=MAC, ONUTYPE=AN5006- 04, ONUI D=54- 5B- 04- B3- 43- A0;
Response:
10. 22. 16. 22 2007- 03- 01 13: 35: 00M CTAG COMPLD
EN=0 ENDESC=No er r or
Meaning:
This command is used to add an AN5006-04 ONU to the 133.5.35.235 OLT.
3.2.13 Deleting an ONU
Functions
This command is used to delete an ONU.
Command format
DEL- ONU: : OLTI D=ol t - name, PONI D=ponport _l ocat i on: CTAG: : ONUI DTYPE=onui d- type, ONUI D=onu- i ndex;
Response format
Complies with the response format mentioned in Section 2.4.
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
64/172
ANM2000 Network Management System Northbound Interface (TL1) Operation Manual
3-26 Version: A
Parameters
ParameterName
Data Type Value Range Remark
OLTID OCTET STRING SIZE (128) The IP address, name, or ID of an OLT
PONID OCTET STRING
SIZE (128)Cabinet-subrack-slot-PON port No.
The PON port identity information. APON port is identified by the cabinet-subrack-slot-PON port No., and in theabsence of any of the cabinet,subrack, slot, PON port No., fill withNA.
ONUIDTYPE OCTET STRING SIZE (128) The ONU ID type (MAC, LOID)
ONUID OCTET STRING SIZE (128)
The ONU ID, and its value can be one
of the following four items: MAC, LOID.It is used to uniquely identify an ONUconnected with the appointed PONport.
Example
Command:
DEL- ONU: : OLTI D=133. 5. 35. 235, PONI D=NA- NA- 4- 4: CTAG: : ONUI DTYPE=MAC, ONUTYPE=AN5006- 04, ONUI D=54- 5B- 04- B3- 43- A0;
Response:
10. 22. 16. 22 2007- 03- 01 13: 35: 00M CTAG COMPLDEN=0 ENDESC=No er r or
Meaning:
This command is used to delete an AN5006-04 ONU from the 133.5.35.235 OLT.
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
65/172
3 TL1 Commands
Version: A 3-27
3.3 Integrated Test Interface
3.3.1 PON Service
3.3.1.1 Pinging an IP from the Equipment (PING)
Functions
This function is used to test the VoIP channel.
Command format
PI NG: : ONUI P=onu name| OLTI D=OLT_name[ , PONI D=ponpor t _l ocat i on, ONUI DTYPE=i d- t ype, ONUI D=onu_i ndex]: CTAG: : I P=i p- address ;
Response format
Complies with the response format on query commands mentioned in Section 2.4.
t i t l e = Pi ng f romONU
Input parameter
Parameter Name Data Type Value Range Remark
ONUIP OCTET STRING SIZE (128)
The IP address, name,or ID of an ONU withthe management IPaddress
OLTID OCTET STRING SIZE (128)The IP address, name,or ID of an OLT
PONID OCTET STRING
SIZE (128)Cabinet
-subrack-slot-PONport No.
The PON port identityinformation. A PON portis identified by thecabinet
-subrack-slot-PON portNo., and in the absenceof any of the cabinet,subrack, slot, PON portNo., fill with NA.
ONUIDTYPE OCTET STRING
SIZE (128)ONU_NAME,MAC,LOID,ONU_NUMBER
The ONU ID type(ONU_NAME, MAC,LOID, ONU_NUMBER)
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
66/172
ANM2000 Network Management System Northbound Interface (TL1) Operation Manual
3-28 Version: A
Parameter Name Data Type Value Range Remark
ONUID OCTET STRING SIZE (128)
The ONU ID, and itsvalue can be one of thefollowing four items:ONU_NAME, MAC,LOID, ONU_NUMBER.It is used to uniquelyidentify an ONUconnected with theappointed PON port.
IP OCTET STRING SIZE (20)The target IP addressof the ping operation
Output parameter
Parameter Name Data Type Value Range Remark
TxPkts INTEGER 0 to 10The number of Txpackets
RxPkts INTEGER 0 to 10The number of Rxpackets
LostPkts INTEGER 0 to 10The number of lostpackets
LostPktRatio INTEGER 0 to 100 Packet loss rate
MinDelay INTEGER 0 to 2000Minimum delay timeUnit: ms
MaxDelay INTEGER 0 to 2000Maximum delay timeUnit: ms
AvgDelay INTEGER 0 to 2000Average delay timeUnit: ms
Example
Command:
PI NG: : ONUI P=133. 5. 35. 237: CTAG: : I P=134. 140. 55. 130;
Response:
FH_134. 140. 55. 130 2010- 07- 01 11: 19: 48M CTAG COMPLDt otal _bl ocks=1bl ock_number =1bl ock_r ecords=1Pi ng f r om ONU- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -TxPkt s RxPkt s Lost Pkt s Lost Pkt Rat i o Mi nDel ay MaxDel ay
AvgDel ay2 2 0 0 16 0 8
Meaning:
This command is used to ping the 134.140.55.130 OLT from the 133.5.35.237ONU.
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
67/172
3 TL1 Commands
Version: A 3-29
3.3.1.2 Querying the NE Equipment Information (LST-DEVINFO)
Functions
Query the equipment type, software version, memory, CPU, temperature, andother information of a certain NE (OLT and ONU).
Command format
LST- DEVI NFO: : ONUI P=onu- name| OLTI D=ol t - name[ , PONI D=ponport - l ocat i on, ONUI DTYPE=i d- t ype, ONUI D=onu- i ndex]: CTAG: : ;
Response format
Complies with the response format on query commands mentioned in Section 2.4.
t i t l e = Pi ng f romONU
Input parameter
Parameter Name Data Type Value Range Remark
ONUIP OCTET STRING SIZE (128)
The IP address, name, or ID
of an ONU with themanagement IP address
OLTID OCTET STRING SIZE (128)The IP address, name, or IDof an OLT
PONID OCTET STRING
SIZE (128)Cabinet-subrack-slot-PONport No.
The PON port identityinformation. A PON port isidentified by the cabinet-subrack-slot-PON port No.,and in the absence of any ofthe cabinet, subrack, slot,PON port No., fill with NA.
ONUIDTYPE OCTET STRING
ONU_NAME,MAC,LOID,ONU_NUMBER
The ONU ID type(ONU_NAME, MAC, LOID,ONU_NUMBER)
ONUID OCTET STRING SIZE (128)
The ONU ID, and its valuecan be one of the following
four items: ONU_NAME,MAC, LOID,ONU_NUMBER. It is used touniquely identify an ONUconnected with theappointed PON port.
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
68/172
ANM2000 Network Management System Northbound Interface (TL1) Operation Manual
3-30 Version: A
Output parameter
Parameter Name Data Type Value Range Remark
DEVNAME OCTET STRING SIZE (128) The equipment name
DEVIP OCTET STRING SIZE (128) The equipment IP address
DT OCTET STRING SIZE (255) The equipment type
DEVER OCTET STRING SIZE (255) The software version
MEM INTEGER 0 to100The memory utilization ratioUnit: %
CPU INTEGER 0 to100The CPU utilizationUnit: %
TEMPERATURE INTEGER -50 to 100The temperature
Unit:
Example
Command:
LST- DEVI NFO: : OLTI D=133. 5. 35. 234, PONI D=NA-NA-4- 1, ONUI DTYPE=LOI D, ONUI D=hg220sn_1: CTAG: : ;
Response:
Li st of Devi ce I nf o- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -DEVNAME DEVI P DT DEVER MEM CPU TEMPERATURE
- - - - HG220 ! ! RP0100 - - - - - -
Meaning:
This command is used to query the NE equipment information of the ONU whoseSN is hg220sn_1 connected to the 133.5.35.234 OLT.
3.3.1.3 Querying the Card Information (LST-BRDINFO)
Functions
Query the type, status, version, etc. of a certain card.
Command format
LST- BRDI NFO: : ONUI P=onu- name| OLTI D=ol t - name[ , PONI D=ponport _l ocat i on, ONUI DTYPE=i d- t ype, ONUI D=onu_i ndex] [ , BOARDI D=boar d- name] : CTAG: : ;
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
69/172
3 TL1 Commands
Version: A 3-31
Response format
Complies with the response format on query commands mentioned in Section 2.4.
t i t l e = Pi ng f romONU
Input parameter
ParameterName
Data Type Value Range Remark
ONUIPOCTETSTRING
SIZE (128)The IP address, name, or ID of anONU with the management IPaddress
OLTID OCTETSTRING
SIZE (128) The IP address, name, or ID of anOLT
PONIDOCTETSTRING
SIZE (128)Cabinet-subrack-slot-PONport No.
The PON port identity information. APON port is identified by the cabinet-subrack-slot-PON port No., and inthe absence of any of the cabinet,subrack, slot, PON port No., fill withNA.
ONUIDTYPEOCTETSTRING
ONU_NAME,MAC,LOID,ONU_NUMBER
The ONU ID type (ONU_NAME,MAC, LOID, ONU_NUMBER)
ONUIDOCTETSTRING
SIZE (128)
The ONU ID, and its value can beone of the following four items:ONU_NAME, MAC, LOID,ONU_NUMBER. It is used touniquely identify an ONU connected
with the appointed PON port.
BOARDIDOCTETSTRING
SIZE (128)Cabinet -subrack-slot
The card identity information. A cardis located in the cabinet-subrack-slot No. mode, and in theabsence of any of the cabinet,subrack, slot, PON port No., fill withNA.
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
70/172
ANM2000 Network Management System Northbound Interface (TL1) Operation Manual
3-32 Version: A
Output parameter
ParameterName
Data Type Value Range Remark
BOARDIDOCTETSTRING
SIZE (128)Cabinet-subrack-slot
The card identity information. A card islocated in the cabinet -subrack-slot No.mode, and in the absence of any of thecabinet, subrack, slot, PON port No., fillwith NA.
BSTATOCTETSTRING
NormalFaultOffline
The card status
BOARDTYPEOCTETSTRING
SIZE (128) The card type
BSERVICEOCTETSTRING
PowerETH
ADSLVDSLPOTSE1GPONEPONSCUOther
The card service type (such as theADSL2P, the SHDSL)
PNUM INTEGER 0 to 64 The number of ports
SWVEROCTETSTRING
SIZE (255) The software version
HWVEROCTETSTRING
SIZE (255) The hardware version
MEM INTEGER 0 to100The memory utilization ratioUnit: %
CPU INTEGER 0 to 100 The CPU utilizationUnit: %
Example
Command:
LST- BRDI NFO: : OLTI D=133. 5. 35. 235, BOARDI D=NA- NA- 4: CTAG: : ;
Response:
DEVNAME DEVI P DT DEVER MEM CPU TEMPERATURE237_AN5006- 20 133. 5. 35. 237AN5006- 20 RP0106 64. 29 2. 33 38
Meaning:
This command is used to query the information of the card in slot 4 of the133.5.35.235 OLT.
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
71/172
3 TL1 Commands
Version: A 3-33
3.3.1.4 Querying the ETH Performance (LST-LANPERF)
Functions
Query the ETH performance of an OLT uplink port or an ONU LAN port.
Command format
LST- LANPERF: :ONUI P=onu_name| OLTI D=ol t _name[ , PONI D=ponport _l ocat i on, ONUI DTYPE=i d- t yp
e, ONUI D=onu_i ndex], PORTI D=l anpor t _i ndex: CTAG: : ;
Response format
Complies with the response format on query commands mentioned in Section 2.4.
Ti t l e = Li st of Et henet per f or mance
Output parameter
Parameter Name Data Type Value Range Remark
OutPkts DOUBLE 0 to 1.85E19 The number of Tx packets
InPkts DOUBLE 0 to1.85E19 The number of Rx packets
OutOctets DOUBLE 0 to1.85E19 The number of Tx bytes
InOctets DOUBLE 0 to1.85E19 The number of Rx bytes
CRC DOUBLE 0 to1.85E19The number of Rx CRC erroredmessages
UnderSizePkts DOUBLE 0 to1.85E19The number of Rx under-sizemessages
OverSizePkts DOUBLE 0 to1.85E19The number of Rx over-sizemessages
InErrors DOUBLE 0 to1.85E19The number of Rx erroredmessages
OutErrors DOUBLE 0 to1.85E19The number of non-Tx erroredmessages
InDiscards DOUBLE 0 to1.85E19The number of discarded Rxmessages
OutDiscards DOUBLE 0 to1.85E19The number of discarded Txmessages
InUnicastPkts DOUBLE 0 to1.85E19 The number of Rx unicast packets
InMulticastPkts DOUBLE 0 to1.85E19 The number of Rx multicast packets
InBroadcastPkts DOUBLE 0 to1.85E19The number of Rx broadcastpackets
OutUnicastPkts DOUBLE 0 to1.85E19 The number of Tx unicast packets
OutMulticastPkts DOUBLE 0 to1.85E19 The number of Tx multicast packets
OutBroadcastPkts DOUBLE 0 to1.85E19The number of Tx broadcastpackets
StateChangeCounters
INTEGER0 to4294967295
The port status changing times
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
72/172
ANM2000 Network Management System Northbound Interface (TL1) Operation Manual
3-34 Version: A
Example
Command:
LST- LANPERF: : OLTI D=133. 5. 35. 234, PORTI D=NA- NA- 29- 1: CTAG: : ;
Response:
Li st of Ethenet perf ormance- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -OutPkt s I nPkt s OutOct ets I nOct ets CRC UnderSi zePkt sOver Si zePkts I nEr r ors Out Er r ors I nDi scards Out Di scar dsI nUni cast Pkt s I nMul t i cast Pkt s I nBr oadcast Pkt s Out Uni cast Pkt s
OutMul t i cast Pkt s OutBr oadcastPkt s StateChangeCounters
6889 643 198010 509876 0 0 0 0 - - 0 - - 197 37 6655 - -0 98 - -
Meaning:
This command is used to query the information of the uplink port 29 of the card inslot 1 under the 133.5.35.234 OLT.
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
73/172
3 TL1 Commands
Version: A 3-35
3.3.1.5 Querying the PON Port Information (LST-PONINFO)
Functions
Query the status and configuration information of an OLT PON port.
Command format
LST- PONI NFO: : OLTI D=ol t - name, PONI D=pon_name: CTAG: : ;
Response format
Complies with the response format on query commands mentioned in Section 2.4.
Ti t l e = Li st of ol t pon port i nf or mat i on
Input parameter
ParameterName
Data Type Value Range Remark
OLTID OCTET STRING SIZE (128)The IP address, name, or ID of anOLT
PONID OCTET STRING
SIZE (128)Cabinet-subrack-slot-PONport No.
The PON port identity information.
A PON port is identified by thecabinet -subrack-slot-PON portNo., and in the absence of any ofthe cabinet, subrack, slot, PONport No., fill with NA.
Output parameter
ParameterName
Data Type Value Range Remark
AdminState OCTET STRINGUPDOWN
The management status
OperState OCTET STRINGUPDOWN
The running status
Example
Command:
AN5116- 02:
LST- PONI NFO: : OLTI D=133. 5. 35. 234, PONI D=NA- NA- 4- 1: CTAG: : ;
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
74/172
ANM2000 Network Management System Northbound Interface (TL1) Operation Manual
3-36 Version: A
Response:
Li st of Boar d I nf o- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -BOARDI D BSTAT BOARDTYPE BSERVI CE PNUM SWVER HWVER MEMCPUNA-1- 4 Nor mal EC4B EPON 4 RP0201 WKE2. 119. 318R1A - - - -
Meaning:
This command is used to query the information of the PON port 1 of the card inslot 4 under the 133.5.35.234 OLT.
3.3.1.6 Querying the ONU Configuration Information(LST-ONUCFG)
Functions
Query the configuration information of an ONU from the OLT, including the ONUstatus, the optical fiber length, the authentication information, etc.
Command format
LST- ONUCFG: :OLTI D=ol t - name, PONI D=ponport _l ocat i on, ONUI DTYPE=i d- t ype, ONUI D=onu- i ndex: CTAG: : ;
Response format
Complies with the response format on query commands mentioned in Section 2.4.
Ti t l e = l i st of ONU i nf o
Input parameter
ParameterName
Data Type Value Range Remark
OLTID OCTET STRING SIZE (128) The IP address, name, or ID ofan OLT
PONID OCTET STRING
SIZE (128)Cabinet-subrack-slot-PONport No.
The PON port identityinformation. A PON port isidentified by the cabinet-subrack-slot-PON port No., andin the absence of any of thecabinet, subrack, slot, PON portNo., fill with NA.
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
75/172
3 TL1 Commands
Version: A 3-37
ParameterName
Data Type Value Range Remark
ONUIDTYPE OCTET STRING
ONU_NAME,MAC,LOID,ONU_NUMBER
The ONU ID type (ONU_NAME,MAC, LOID, ONU_NUMBER)
ONUID OCTET STRING SIZE (128)
The ONU ID, and its value canbe one of the following fouritems: ONU_NAME, MAC,LOID, ONU_NUMBER. It isused to uniquely identify anONU connected with theappointed PON port.
Output parameter
ParameterName
Data Type Value Range Remark
AdminState OCTET STRINGUPDOWN
The management status
OperState OCTET STRINGUPPower-OffLOS
The running status
AUTH OCTET STRINGMACLOID
The authentication mode
AUTHINFO OCTET STRING SIZE (64)
The authentication information.If AUTH is set to MAC,
AUTHINFO means the MACaddress; If AUTH is set to LOID,
AUTHINFO means the LOIDvalue.
Length INTEGER 0 to 100The optical fiber length
Unit: kmUsFixedBw INTEGER 0 to 40000
The uplink fixed bandwidthUnit: Mbit/s
UsAssuredBw
INTEGER 0 to 40000The uplink assured bandwidthUnit: Mbit/s
UsMaxBw INTEGER 0 to 40000The uplink maximum bandwidthUnit: Mbit/s
DsMaxBw INTEGER 0 to 40000The downlink maximumbandwidthUnit: Mbit/s
Example
Command:
LST- ONUCFG: : OLTI D=133. 5. 35. 234, PONI D=NA- NA- 4- 1, ONUI DTYPE=LOI D, ONUI D=511603: CTAG: : ;
Response:
l i st of ONU i nf o- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -Admi nStat e OperSt at e AUTH AUTHI NFO Length UsFi xedBwUsAssur edBw UsMaxBw DsMaxBwUP UP LOI D 551607 0. 002 0 0 1000 1000
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
76/172
ANM2000 Network Management System Northbound Interface (TL1) Operation Manual
3-38 Version: A
Meaning:
This command is used to query the configuration information of the ONU underPON port 1 of the card in slot 4 under the 133.5.35.234 OLT.
3.3.1.7 Querying the ONU Status (LST-ONUSTATE)
Functions
Query the status and authentication information of an ONU or all ONUs under thePON port of an OLT.
Command format
LST- ONUSTATE: :OLTI D=ol t - name, PONI D=ponport _l ocat i on[, ONUI DTYPE=i d- t ype, ONUI D=onu- i ndex] : CTAG: : ;
Response format
Complies with the response format on query commands mentioned in Section 2.4.
Ti t l e = l i st of ONU st at e
Input parameter
Parameter Name Data Type Value Range Remark
OLTID OCTET STRING SIZE (128)The IP address, name, or IDof an OLT
PONID OCTET STRING
SIZE (128)Cabinet-subrack-slot-PON port No.
The PON port identityinformation. A PON port isidentified by the cabinet-subrack-slot-PON port No.,and in the absence of any ofthe cabinet, subrack, slot,PON port No., fill with NA.
ONUIDTYPE OCTET STRING
ONU_NAME,MAC,LOID,ONU_NUMBER
The ONU ID type
(ONU_NAME, MAC, LOID,ONU_NUMBER)
ONUID OCTET STRING SIZE (128)
The ONU ID, and its value canbe one of the following fouritems: ONU_NAME, MAC,LOID, ONU_NUMBER. It isused to uniquely identify anONU connected with theappointed PON port.
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
77/172
3 TL1 Commands
Version: A 3-39
Output parameter
Parameter Name Data Type Value Range Remark
ONUID OCTET STRING SIZE (128)
The ONU ID, and its value isONU_Number. It is used touniquely identify an ONUconnected with the appointedPON port.
AdminState OCTET STRINGUPDOWN
The management status
OperState OCTET STRINGUPPower-OffLOS
The running status
AUTH OCTET STRINGMACLOID
The authentication mode
AUTHINFO OCTET STRING SIZE (64)
The authentication information.If AUTH is set to MAC,
AUTHINFO means the MACaddress; If AUTH is set toLOID, AUTHINFO means theLOID value.
ONUIP OCTET STRINGThe ONU management IPaddress
Example
Command:
LST- ONUSTATE: : OLTI D=133. 5. 35. 235, PONI D=NA-NA-4- 4, ONUI DTYPE=LOI D, ONUI D=551607: CTAG: : ;
Response:
l i st of ONU st at e- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -ONUI D Admi nSt at e Oper St at e AUTH AUTHI NFO ONUI P1 UP UP LOI D 551607 - -
Meaning:
This command is used to query the configuration status information of the ONUunder PON port 4 of the card in slot 4 under the 133.5.35.235 OLT.
5/21/2018 WAN ANM2000 Network Management System TL1 Operation Manual
78/172
ANM2000 Network Management System Northbound Interface (TL1) Operation Manual
3-40 Version: A
3.3.1.8 Querying the Optical Module DDM Information(LST-OMDDM)
Functions
Querying the DDM information of an optical module, and the optical module canbe an ETH optical module, an OLT PON optical module, or an ONU PON opticalmodule.
Command format
LST- OMDDM: : ONUI P=onu- name| OLTI D=ol t - name[ , PONI D=ponport _l ocat i on][ , ONUI DTYPE=i d- t ype, ONUI D=onu- i ndex][ , PORTI D=l anpor t _i ndex] [ , PEERFLAG=f l ag]: CTAG: : ;
Input parameter
Parameter Name Data Type Value Range Remark
ONUIP OCTET STRING SIZE (128)The IP address, name, or IDof an ONU with themanagement IP address.
OLTID OCTET STRING SIZE (128)The IP address, name, or IDof an OLT
PONID OCTET STRING
SIZE (128)Cabinet-subrack-slot-PONport No.
The PON port identity
information. A PON port isidentified by the cabinet-subrack-slot-PON port No.,and in the absence of any ofthe cabinet, subrack, slot,PON port No., fill with NA.
ONUIDTYPE OCTET STRING
ONU_NAME,MAC,LOID,ONU_NUMBER
The ONU ID type(ONU_NAME, MAC, LOID,ONU_NUMBER)
ONUID OCTET STRING SIZE (128)
The ONU ID, and its valuecan be one of the followingfour items: ONU_NAME,MAC, LOID,ONU_NUMBER. It is used touniquely identify an ONUconnected with the
appointed PON port.
PORTID OCTET STRING
SIZE (128)Cabinet-subrack-slot-portNo.
A card is identified by thecabinet -subr