Wall MountedL/M/P/311 Series
TM-FT-0415-BTECHNICAL MANUALDownloaded from www.Manualslib.com manuals search engine
1. Model Name .......................................................................................................... 2 2. Features ................................................................................................................. 4
3. Specifications ........................................................................................................ 5 4. ApplicationInformation ........................................................................................ 13 OperatingRange ....................................................................................... 13 Controllers ................................................................................................ 13
5. Installations .......................................................................................................... 18
6.WiringDiagrams .................................................................................................. 33
7. Servicing&Maintenance .................................................................................... 38
8. Troubleshooting ................................................................................................... 40
9. DimensionalData ................................................................................................ 41
10.ExplodedView&PartList ................................................................................... 47
Note:Installationandmaintenancearetobeperformedonlybyqualifiedpersonnelwhoare familiarwithlocalcodesandregulations,andexperiencedwiththistypeofequipment.
Caution:Sharpedgesandcoilsurfacesareapotentialinjuryhazard.Avoidcontactwiththem.
Warning:Movingmachineryandelectricalpowerhazard.Maycauseseverepersonnel injuryordeath.Disconnectandlockoffpowerbeforeservicingequipment.
TableofContents
Downloaded from www.Manualslib.com manuals search engine
2
TM-F
T-04
15-B
1. Model Name
Controller
L/I : Wireless ControllerM/J : Wired Controller
Power Supply
Series
L : L SeriesM : M SeriesP : P Series
Type of Air-Conditioner
FT : Wall Mounted
Capacity Index
10 : Based on Btu/hr
Refrigerant
Blank : R22N : R410A
L10 V1 LFT
V1 : Single Phase, 220-240V, 50Hz
Indoor
Downloaded from www.Manualslib.com manuals search engine
3
TM-F
T-04
15-B
Power Supply
Series
C : C SeriesF : F Series
Type of Air-Conditioner
R : Single Split Condensing Unit
Capacity Index
18 : Based on Btu/hr
Refrigerant
Blank : R22N : R410A
C18 V1R
V1 : Single Phase, 220-240V, 50Hz
Outdoor
Downloaded from www.Manualslib.com manuals search engine
4
TM-F
T-04
15-B
2. Features
Indoor Air QualityDaikin Cooling King M-series has Plasma Generator which it is an Indoor Air Quality (IAQ) solutiontoeffectivelykillthebacteriabydamagingmicrobialDNAandsurfacestructureswithoutbeing harmfultohumantissues.Furthermore,balancingtheionizationinyourhometocombattheillfeelings associatedwithourstressfullifestylesandcreatestherefreshingenvironmentresemblingthenature.
Stylish Flat-PanelIdealblendof styleand function.Regular cleaning iseasierby justwiping theflat frontpanel.This ensurestheair-conditionerwillalwayslookbrandnewallthetime.
Wireless Remote Controller• ThecompactLCDtransmitterisabletooperatetheairconditionerunitwithinthedistanceof8meters.• Fanspeedcanbesetathigh/medium/low/superloworautomatic.• Sleep mode auto control will gradually increase or decrease the setting temperature to provide acomfortablesurroundingforsleeping.
• Airflowdirectioncanbecontrolledautomatically.• Roomtemperatureiscontrolledbyelectronicthermostat.• TherealtimetimerallowstheairconditionertobeswitchedOnandOffautomaticallybasedonusersettings.• Turbomodefunctionisavailabletoenablestherequiredsettemperaturetobeachievedinashorttime.
Auto Random RestartAutorandomrestartfunctionallowstheunittoautomaticrestartasthelastsettingconditionwhenthepowersupplyisresumedafterpowerfailure.
Self DiagnosisThemicroprocessorprovidesthepossibilitytodetectanddiagnoseanyfaultormalfunctionthatoccursinthesystem.TheerrorwillbereflectedbytheblinkingoftheLEDlights.
Built in Starter (BIS)OfferingsuperiortechnologyapprovedbyJBE,Daikinairconditionerincorporateanaccuratethermaloverloadprotectortopreventoverloadingormissadjustment.
3333
High Efficiency Heat ExchangerThe compact design of the 3-fold structure heat exchanger provides a large surface for better and more efficient heat exchange.The unique Hydrophilic slit fin has greatly improved the air flow and contact surfaces with the air, thusboosting the cooling capacity
Hydrophilic Slit F
in
Slit Fin
Plain Fin
Hea
t Tra
nsfe
r Effi
cien
cy
10%
15%
Rotary CompressorTheeverpopularrotarycompressorismoreenergyefficientandhasahigheroutputtoweightratio.
Space SavingNospaceisrequiredoneitherfloororceiling.Thisnewlydevelopedsuperslimdesignforwallmountingmaximizesfloorspaceusageandenhancesceilingappearancewhereceilingsarelow.
Downloaded from www.Manualslib.com manuals search engine
5
TM-F
T-04
15-B
3.Specifications
Specifications (R22)FT10LV1LFT10MV1IFT10LV1MFT10MV1J
R09CV1
FT15LV1LFT15MV1IFT15LV1MFT15MV1J
R15CV1
FT20LV1LFT20MV1IFT20LV1MFT20MV1J
R18CV1
FT20LV1LFT20MV1IFT20LV1MFT20MV1J
R20CV1
WIRELESS
WIRED
Btu/hr 10000 13000W 2931
0.8238100.7
W 980 1220A 4.38 5.36
V/Ph/HzBtu/hr/W 10.20 10.66
l/s / CFM
l/s / CFM
161 / 342 168 / 355169 / 358 176 / 372
l/s / CFM 133 / 282 141 / 298
l/s / CFM 106 / 22599 / 209
114 / 242106 / 225
dBA 39 / 38 / 33 / 27 / 25 41 / 40 / 35 / 29 / 28
mm/in 288 / 11.3288 / 11.3
mm/in800 / 31.5800 / 31.5
mm/in206 / 8.1216 / 8.5
mm/in 344 / 13.5
mm/in 874 / 34.4mm/in 274 / 10.8
kg/lb
-
-YES
YES9 / 19.8
mm/in 19 / 0.75
CONTROLAIR DISCHARGE
220-240 / 1 / 50
AUTO LOUVER (UP & DOWN) & GRILLE (LEFT & RIGHT)
R22OUTDOOR CAP. TUBE
IND
OO
R U
NIT
SOUND PRESSURE LEVEL (T/H/M/L/Q)
AIR FLOW
HIGH TURBO
MEDIUM
UNITDIMENSION
HEIGHTL SERIESM SERIESL SERIES
L SERIESM SERIES
M SERIES
L SERIES
L SERIESM SERIES
M SERIES
WIRELESS REMOTE CONTROL OR WIRED CONTROLLER (OPTIONAL)
UNIT NET WEIGHT
OTHERFEATURES
PLASMA
NEGATIVE ION
MODEL
OUTDOOR UNIT
LOWl/s / CFMQUIET
INDOOR UNIT
NOMINAL CAPACITY
SENSIBLE HEAT FACTORNOMINAL TOTAL INPUT POWER
OPERATION
POWER SOURCE
REFRIGERANT TYPEEER
WIDTH
PACKINGDIMENSION
NOMINAL RUNNING CURRENT
REFRIGERANT CONTROL (EXPANSION DEVICE)
DEPTH
HEIGHT
WIDTHDEPTH
CONDENSATE DRAIN SIZE
195005715
18508.12
180005275
0.700.7316307.16
11.04
280 / 594251 / 531
224 / 474199 / 422180 / 381
44 / 42 / 39 / 36 / 35310 / 12.2310 / 12.2
1065 / 41.91065 / 41.9
224 / 8.8233 / 9.2
386 / 15.2
1136 / 44.7314 / 12.4
14 / 30.8
1) DUE TO OUR POLICY OF INNOVATION, ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO INTERNATIONAL STANDARDS SUCH AS ISO 5151 AND AHRI 210/240. 3) NOMINAL COOLING CAPACITY ARE BASED ON THE CONDITIONS BELOW : COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR 4) SOUND PRESSURE LEVEL ARE MEASURED IN OYLM R&D SOUND ROOM. SOMEHOW DURING ACTUAL OPERATION, THE RESULT WILL BE HIGHER AS A RESULT OF AMBIENT CONDITION.
10.54
mm/inmm/in
FAN
TYPE CROSS FLOW FANQUANTITY 1MATERIAL GLASS REINFORCED ACRYL STYRENE RESINDRIVE DIRECTDIAMETER 92 / 3.6LENGTH 607 / 23.9
FAN MOTOR
TYPE INDUCTIONQUANTITY 1INDEX OF PROTECTION (IP) IP24
POWER SOURCERATED INPUT POWERRATED RUNNING CURRENTMOTOR OUTPUT
INSULATION GRADE
POLES
SPEED RPM
V/Ph/HzWAW
TURBOHIGHMEDIUMLOWSILENT
CLASS E220 - 240 / 1 / 50
37
128012301050880830
132012701100930880
400.2018
4
IP44
102 / 4.02867 / 34.13
610.3026
11301050960875800
mm/inmm/in
mm/inm²/ft²
COIL
TUBEMATERIAL SEAMLESS INNER GROOVE COPPERDIAMETER 7.00 / 0.276THICKNESS 0.28 / 0.011
FIN
MATERIAL ALUMINIUMTHICKNESS 0.11 / 0.0043FACE AREA 0.18 / 1.94ROW 2FIN PER INCH 18
0.24 / 0.00945
0.105 / 0.00410.29 / 3.12
pcLENGTH mm/inWIDTH mm/inTHICKNESS mm/in
MATERIAL
AIRQUALITY
FILTER
TYPE
302 / 11.9280 / 11.0
2.0 / 0.1CASING PLASTIC
QUANTITY
SIZE 306 / 12.1
SARANET2
421 / 16.5
kg/lb 0.60 / 1.3 0.60 / 1.3REFRIGERANT CHARGE 0.90 / 1.98 0.83 / 1.83
Downloaded from www.Manualslib.com manuals search engine
6
TM-F
T-04
15-B
Specifications (R22) - Continued
MODEL INDOOR UNITWIRELESS
WIRED
OUTDOOR UNITl/s / CFM 321 / 680 453 / 960
dBA 45 49
mm/in 497 / 19.6 543 / 21.4mm/in 600 / 23.6 700 / 27.6mm/in 245 / 9.6 250 / 9.8mm/in 535 / 21 596 / 23.51mm/in 721 / 28.4 803 / 31.6mm/in 330 / 13 323 / 12.7kg/lb 25 / 55 28 / 61.7
LIQUID mm/in 6.35 / 1/4GAS mm/in 9.52 / 3/8 12.7 / 1/2
FLARE VALVE
UNITDIMENSION
HEIGHT
WIDTH
OU
TD
OO
R U
NIT
UNIT NET WEIGHT
PIPECONNECTION
TYPE
SIZE
WIDTHPACKINGDIMENSION
DEPTH
DEPTH
HEIGHT
AIR FLOW
SOUND PRESSURE LEVEL
614 / 1300
5152
654 / 25.7855 / 33.7328 / 12.9693 / 27.3990 / 39.0415 / 16.343 / 94.8
15.88 / 5/8
1) DUE TO OUR POLICY OF INNOVATION, ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO INTERNATIONAL STANDARDS SUCH AS ISO 5151 AND AHRI 210/240. 3) NOMINAL COOLING CAPACITY ARE BASED ON THE CONDITIONS BELOW : COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR 4) SOUND PRESSURE LEVEL ARE MEASURED IN OYLM R&D SOUND ROOM. SOMEHOW DURING ACTUAL OPERATION, THE RESULT WILL BE HIGHER AS A RESULT OF AMBIENT CONDITION.
mm/in
cm²/fl.oz
QUANTITY
355 / 14.0 401 / 15.8DIAMETERINDUCTION
QUANTITY 1
1PROPELLER
MATERIAL ASG20DRIVE DIRECT
FAN
TYPE
COMPRESSOR
TYPE ROTARY
FAN MOTOR
TYPE
OIL AMOUNTOIL TYPE SUNISO-4GSI / FREOL-K56
330 / 11 350 / 11.8
32 740.17 0.3318 30
6
751
860SPEED RPM
V/Ph/HzWAW
POWER SOURCERATED INPUT POWERRATED RUNNING CURRENTMOTOR OUTPUT
INSULATION GRADE
POLES
220 - 240 / 1 / 50B F
CLASS EPOWER SOURCECAPACITORRATED INPUT POWER
RATED RUNNING CURRENT LOCKED ROTOR AMP.
INSULATION GRADEV/Ph/Hz
µF
WAA
30.0 30.0
911 11064.01 4.8317.5 25
220 - 240 / 1 / 50
600 / 20.3600 / 20.3
455 / 17.9
IP23
770.34328
680
770.34326
40
14926.52
36
35
1712
7.4841
INDEX OF PROTECTION (IP)
m²/ft²
mm/in 7.00 / 0.276mm/in
mm/in 0.11 / 0.004
0.29 / 3.14 0.35 / 3.82
118 20 20
MATERIAL
ALUMINIUMTHICKNESS
FIN
MATERIALCOIL
TUBEMATERIAL SEAMLESS INNER GROOVE COPPERDIAMETER
THICKNESS
FACE AREA
ROWFIN PER INCH
CASING GALVANISED STEEL
0.51 / 5.47
0.23 / 0.009
FT10LV1LFT10MV1IFT10LV1MFT10MV1J
R09CV1
FT15LV1LFT15MV1IFT15LV1MFT15MV1J
R15CV1
FT20LV1LFT20MV1IFT20LV1MFT20MV1J
R18CV1
FT20LV1LFT20MV1IFT20LV1MFT20MV1J
R20CV1
Downloaded from www.Manualslib.com manuals search engine
7
TM-F
T-04
15-B
Specifications (R22)FT25LV1LFT25MV1IFT25LV1MFT25MV1J
R25CV1Btu/hr 24000
W 7034
W 2675A
0.71
12.0V/Ph/HzBtu/hr/W 8.97
l/s / CFMl/s / CFM
290 / 614303 / 641
l/s / CFM 253 / 537l/s / CFMl/s / CFM
224 / 474197 / 418
dBA 48 / 46 / 43 / 40 / 37
mm/in 310 / 12.2310 / 12.2
mm/in1065 / 41.91065 / 41.9
mm/in 224 / 8.8233 / 9.2
mm/in 386 / 15.2mm/in 1136 / 44.7mm/in 314 / 12.4
--
--
YES
YESkg/lb 14 / 30.8
mm/in 19 / 0.75
NOMINAL RUNNING CURRENT
REFRIGERANT CONTROL (EXPANSION DEVICE)
WIDTH
PACKINGDIMENSION
OTHERFEATURES
CONDENSATE DRAIN SIZE
DEPTH
HEIGHTWIDTHDEPTH
PLASMA
NEGATIVE ION
REFRIGERANT TYPEEER
WIRELESS REMOTE CONTROL OR WIRED CONTROLLER (OPTIONAL)
UNIT NET WEIGHT
MODEL
OUTDOOR UNIT
LOWQUIET
INDOOR UNITWIRELESS
WIRED
NOMINAL CAPACITY
SENSIBLE HEAT FACTORNOMINAL TOTAL INPUT POWER
OPERATION
POWER SOURCE
CONTROLAIR DISCHARGE
IND
OO
R U
NIT
SOUND PRESSURE LEVEL (T/H/M/L/Q)
AIR FLOWHIGH TURBO
MEDIUM
UNITDIMENSION
HEIGHT L SERIESM SERIESL SERIESM SERIESL SERIES
L SERIES
L SERIES
M SERIES
M SERIES
M SERIES
220-240 / 1 / 50
AUTO LOUVER (UP & DOWN) & GRILLE (LEFT & RIGHT)
R22OUTDOOR CAP. TUBE
mm/inmm/in
FANMOTOR
QUANTITYMATERIALDRIVE
TYPE
FAN
QUANTITYINDEX OF PROTECTION (IP) IP44
CROSS FLOW FAN
DIAMETERLENGTHTYPE
1
DIRECTGLASS REINFORCED ACRYL STYRENE RESIN
102 / 4.02867 / 34.13
INDUCTION1
CLASS EIP24
CLASS B220-240 / 1 / 50POWER SOURCE
RATED INPUT POWERRATED RUNNING CURRENTMOTOR OUTPUT
INSULATION GRADE
POLES
SPEED RPM
TURBOHIGHMEDIUMLOWSILENT
V/Ph/HzWAW
1280123511101010930
-130012001080
-
4
720.3430
mm/inmm/in
mm/inm²/ft²
COIL
FIN
TUBE
ROWFIN PER INCH
DIAMETERTHICKNESS
THICKNESSFACE AREA
MATERIAL
MATERIAL SEAMLESS INNER GROOVE COPPER7.00 / 0.276
0.24 / 0.00945ALUMINIUM
0.105 / 0.00410.29 / 3.12
218
pcLENGTH mm/inWIDTH mm/inTHICKNESS mm/in
AIRQUALITY
FILTERSIZE
QUANTITYTYPE
306 / 12.12.0 / 0.1
SARANET2
421 / 16.5
MATERIALCASING PLASTIC
1) DUE TO OUR POLICY OF INNOVATION, ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO INTERNATIONAL STANDARDS SUCH AS ISO 5151 AND AHRI 210/240. 3) NOMINAL COOLING CAPACITY ARE BASED ON THE CONDITIONS BELOW : COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR 4) SOUND PRESSURE LEVEL ARE MEASURED IN OYLM R&D SOUND ROOM. SOMEHOW DURING ACTUAL OPERATION, THE RESULT WILL BE HIGHER AS A RESULT OF AMBIENT CONDITION.
kg/lb 1.15 / 2.53REFRIGERANT CHARGE
FT311V1L
FT311V1M
R31CV128,00082100.70315013.1
8.89
1.85 / 4.08
316 / 670-
-
297 / 630236 / 500
49 / 47 / 45
360 / 14.2
1200 / 47.2
200 / 7.9
420 / 16.51267 / 49.9260 / 10.2
17 / 37.4820 / 0.79
106 / 4.17950 / 37.4
700.340
9.52 / 0.3750.35 / 0.013
0.11 / 0.00430.291 / 3.130
3330 / 13.0317 / 12.41.8 / 0.07
Downloaded from www.Manualslib.com manuals search engine
8
TM-F
T-04
15-B
Specifications (R22) - Continued
mm/in
cm³/ fl.oz. 700 / 24.6
INDOOR UNIT
WIRELESS
WIRED
OUTDOOR UNIT
MODEL
FAN MATERIAL
DRIVE
TYPE
QUANTITY
DIAMETER
COMPRESSOR
TYPE
OIL TYPE
INDEX OF PROTECTION (IP)
FAN MOTOR
OIL AMOUNT
DIRECT
457 / 18.0
PROPELLER
QUANTITY
TYPE
ASG20
455 / 17.9
ATMOS NM56M or SUNISO 4GDID
1
INDUCTION
1
IP23 IP54
ROTARY
V/Ph/Hz
W
A
W
POWER SOURCE
RATED INPUT POWER
RATED RUNNING CURRENT
MOTOR OUTPUT
INSULATION GRADE
POLES
SPEED RPM
220 - 240 / 1 / 50
CLASS F CLASS B
121
0.53
874840
60
6
POWER SOURCE
CAPACITOR
RATED INPUT POWER
RATED RUNNING CURRENT
LOCKED ROTOR AMP.
INSULATION GRADE
V/Ph/Hz
µF
W
A
A
45
2482
11.13
56
CLASS E
220 - 240 / 1 / 50
m²/ft²
mm/in
mm/in
ALUMINIUM
mm/in
0.61 / 6.58
1
20
2
18
MATERIAL
MATERIAL
MATERIAL
ROW
FIN PER INCH
DIAMETER
THICKNESS
THICKNESS
FACE AREA
CASING
COIL
FIN
TUBE 7.00 / 0.276
SEAMLESS INNER GROOVE COPPER
GALVANISED STEEL
0.23 / 0.009
0.11 / 0.0043
1) DUE TO OUR POLICY OF INNOVATION, ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO INTERNATIONAL STANDARDS SUCH AS ISO 5151 AND AHRI 210/240. 3) NOMINAL COOLING CAPACITY ARE BASED ON THE CONDITIONS BELOW : COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR 4) SOUND PRESSURE LEVEL ARE MEASURED IN OYLM R&D SOUND ROOM. SOMEHOW DURING ACTUAL OPERATION, THE RESULT WILL BE HIGHER AS A RESULT OF AMBIENT CONDITION.
OU
TD
OO
R U
NIT
l/s / CFM 755 / 1600
dBA 52
mm/in 756 / 29.8
mm/in 855 / 33.7
mm/in 328 / 12.9
mm/in 793 / 31.2
mm/in 990 / 39.0
mm/in 415 / 16.3
kg/lb 50 / 110.2
LIQUID mm/in 9.52 / 3/8
GAS mm/in 15.88 / 5/8
WIDTH
HEIGHT
AIR FLOW
SOUND PRESSURE LEVEL
HEIGHTPACKINGDIMENSION
DEPTH
DEPTH
UNIT NET WEIGHT
PIPECONNECTION
TYPE
SIZE
WIDTH
UNITDIMENSION
FLARE VALVE
808 / 1712
56
756 / 29.8
855 / 33.7
328 / 12.9
793 / 31.2
990 / 39.0
415 / 16.3
57 / 126
GLASS REINFORCED ACRYL STYRENE RESIN
139
0.6
75
900 / 31.70
50
2941
12.2
72
0.62 / 6.63
FT25LV1L
FT25MV1I
FT25LV1M
FT25MV1J
R25CV1
FT311V1L
FT311V1M
R31CV1
Downloaded from www.Manualslib.com manuals search engine
9
TM-F
T-04
15-B
Specifications (R410A)FTN10PV1LFTN10MV1I9FTN10PV1MFTN10MV1J9
RN10FV1
FTN15PV1LFTN15MV1I9FTN15PV1MFTN15MV1J9
RN15FV1
FTN20PV1LFTN20MV1I9FTN20PV1MFTN20MV1J9
RN20CV1
FTN25PV1LFTN25MV1I9FTN25PV1MFTN25MV1J9
RN25CV1Btu/hr 9500 12000 18000 22000
W 2784 3517 5275 64480.82 0.75 0.76 0.75
W 870 1105 1835 2060A 3.86 4.94 8.10 9.14
V/Ph/HzBtu/hr/W 10.92 10.86 9.81 10.68
l/s / CFM 169 / 358 176 / 372 280 / 594 303 / 641l/s / CFM 161 / 342 168 / 355 251 / 531 290 / 614l/s / CFM 133 / 282 140 / 298 224 / 474 253 / 537l/s / CFM 106 / 225 114 / 242 199 / 422 224 / 474l/s / CFM 99 / 209 106 / 225 180 / 381 197 / 418
dBA 39/ 38/ 33/ 27/ 25 41/ 40/ 35/ 29/ 28 44/ 42/ 39/ 36/ 35 48/ 46/ 43/ 40/ 37
mm/inmm/inmm/in
mm/in
kg/lb 0.75 / 1.65 0.88 / 1.94 1.00 / 2.20 1.70 / 3.75REFRIGERANT CHARGE
P-SERIESM-SERIESP-SERIESM-SERIES
-YES
-
OTHERFEATURES
PLASMA
288 / 11.3
800 / 31.5
212 / 8.3DEPTHM-SERIES
YES
310 / 12.2
1065 / 41.9
228 / 9.0
P-SERIESM-SERIES
mm/in
P-SERIES mm/in
kg/lbUNIT NET WEIGHTCONDENSATE DRAIN SIZE
AIR FLOW
TURBO
PACKINGDIMENSION
HEIGHTWIDTHDEPTH
P-SERIESHEIGHTM-SERIES
WIDTH
INDO
OR
UNIT
CONTROL AIR DISCHARGEOPERATION
HIGH MEDIUMLOW
SOUND PRESSURE LEVEL (T/H/M/L/Q)
UNITDIMENSION
NEGATIVEION
MODEL
OUTDOOR UNIT
NOMINAL CAPACITY
NOMINAL TOTAL INPUT POWER NOMINAL RUNNING CURRENT
INDOOR UNITWIRELSS
WIRED
220 - 240 / 1 / 50
R410AOUTDOOR CAP TUBE
SENSIBLE HEAT FACTOR
LOUVER UP & DOWNWIRELESS REMOTE CONTROL OR WIRED CONTROLLER (OPTIONAL)
POWER SOURCEEERREFRIGERANT TYPEREFRIGERANT CONTROL (EXPANSION DEVICE)
QUIET
216 / 8.5 233 / 9.2
mm/in
344 / 13.5 386 / 15.2874 / 34.4 1136 / 44.7274 / 10.8 314 / 12.4
9 / 19.8 14 / 30.819.05 / 0.75
1) DUE TO OUR POLICY OF INNOVATION, ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO INTERNATIONAL STANDARDS SUCH AS ISO 5151 AND AHRI 210/240. 3) NOMINAL COOLING CAPACITY ARE BASED ON THE CONDITIONS BELOW : COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR 4) SOUND PRESSURE LEVEL ARE MEASURED IN OYLM R&D SOUND ROOM. SOMEHOW DURING ACTUAL OPERATION, THE RESULT WILL BE HIGHER AS A RESULT OF AMBIENT CONDITION.
mm/ inmm/ in
V / Ph / HzW 37 42 61 72A 0.19
128012301050880830
132012701100930880
11301050960875800
1280123511101010930
0.21 0.30 0.34W 26 30
FANMOTOR
TYPEQUANTITYINDEX OF PROTECTION (IP)INSULATION GRADEPOWER SOURCERATED INPUT POWERRATED RUNNING CURRENTMOTOR OUTPUT POLES
SPEED
FAN
TYPEQUANTITYMATERIALDRIVE
LENGTHDIAMETER
CROSS FLOW
DIRECT
1 PHASE SCR
1ASG30
92 / 3.62 102 / 4.02
E
184
607 / 23.9 867 / 34.13
120
230 / 1 / 50
mm / in
RPM
mm / in
mm/ in
FIN PER INCH
COIL
TUBEMATERIAL
TURBOHIGHMEDIUMLOWQUIET
DIAMETERTHICKNESS
FIN
MATERIALTHICKNESSFACE AREAROW
18
COPPER7.00 / 0.276
ALUMINIUM
0.18 / 1.93 0.29 / 3.122
0.1 / 0.0039
0.2 / 0.0079
m² / ft²
pcmm / in mm / in mm / in
FILTER
TYPEQUANTITY
SIZELENGTHWIDTHTHICKNESS
302 / 11.89AIRQUALITY
SARANET2
421 / 16.57280 / 11.02 306 / 12.05
2 / 0.08 2 / 0.08MATERIALCASING PLASTIC
Downloaded from www.Manualslib.com manuals search engine
10
TM-F
T-04
15-B
Specifications (R410A) - Continued
mm/ in
B B F F
V / Ph / Hz
W 50
0.22
51 78 121
A
930
0.23
920
0.34 0.53
W
RPM
20 32
710
61
840
cm³ / fl. Oz. 330 320 670
V / Ph / Hz
µF 35 50
W 783 1012 1696 1867
A 3.45 4.50 7.46 8.27
A 18.0 24.50 32 32
mm / in 7 / 0.28
mm / in 0.2 / 0.0079
mm / in
m² / ft² 0.33 / 3.55 0.32 / 3.44 0.51 / 5.49 0.50 / 5.38
1 2 1 2
18 18 20 18
MATERIALCASING
ROW
FIN PER INCH
COIL
TUBE
MATERIAL
DIAMETER
THICKNESS
FIN
MATERIAL
THICKNESS
FACE AREA
COMPRESSOR
TYPE
OIL TYPE
OIL AMOUNT
INSULATION GRADE
POWER SOURCE
LOCKED ROTOR AMP.
RATED INPUT POWER
RATED RUNNING CURRENT
FANMOTOR
TYPE
QUANTITY
INDEX OF PROTECTION (IP)
INSULATION GRADE
POWER SOURCE
RATED INPUT POWER
RATED RUNNING CURRENT
MOTOR OUTPUT
POLESSPEED
FAN
OU
TD
OO
R U
NIT
TYPE
QUANTITY
MATERIAL
DRIVE
DIAMETER
MODEL
OUTDOOR UNIT
INDOOR UNIT
WIRELESS
WIRED
CAPACITOR
PROPELLER
DIRECT
INDUCTION370 / 14.6 455 / 17.9
0.1 / 0.0039
GALVANISE STEEL
COPPER
ALUMINIUM
6
ROTARY
FV50SNMOC Ze-Gles RB68EPHAF68D1
1
ASG 20
1
23
230 / 1 / 50
E
220-240/1/50
1) DUE TO OUR POLICY OF INNOVATION, ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO INTERNATIONAL STANDARDS SUCH AS ISO 5151 AND AHRI 210/240. 3) NOMINAL COOLING CAPACITY ARE BASED ON THE CONDITIONS BELOW : COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR 4) SOUND PRESSURE LEVEL ARE MEASURED IN OYLM R&D SOUND ROOM. SOMEHOW DURING ACTUAL OPERATION, THE RESULT WILL BE HIGHER AS A RESULT OF AMBIENT CONDITION.
l/s / CFM 438 / 927 390/ 827 675 / 1430 755 / 1600
dBA 46 48 49 52
mm/in 654 / 25.7
mm/in 855 / 33.7
mm/in 328 / 12.9
mm/in 693 / 27.3
mm/in 990 / 39.0
mm/in 415 / 16.3
kg/lb 28 / 61.7 29 / 63.9 43 / 94.8 47 / 103.6
mm/in
mm/in 9.52 / 3/8 12.7 / 1/2 12.7 / 1/2 15.88 / 5/8
HEIGHT
WIDTH
DEPTH
UNIT NET WEIGHT
PIPECONNECTION
TYPE
SIZELIQUID
GAS
AIR FLOW
SOUND PRESSURE LEVEL
UNITDIMENSION
HEIGHT
WIDTH
DEPTH
PACKINGDIMENSION
550 / 21.7
658 / 25.9
273 / 10.7
580 / 22.8
775 / 30.5
355 / 14.0
FLARE
6.35 / 1/4
FTN10PV1L
FTN10MV1I9
FTN10PV1M
FTN10MV1J9
RN10FV1
FTN15PV1L
FTN15MV1I9
FTN15PV1M
FTN15MV1J9
RN15FV1
FTN20PV1L
FTN20MV1I9
FTN20PV1M
FTN20MV1J9
RN20CV1
FTN25PV1L
FTN25MV1I9
FTN25PV1M
FTN25MV1J9
RN25CV1
Downloaded from www.Manualslib.com manuals search engine
11
TM-F
T-04
15-B
Specifications (R410A)FTN311V1L
FTN311V1M
RN28CV1
Btu/hr 26,000
W 7620
0.69
W 2560
A 12.20
V/Ph/Hz 220 - 240 / 1 / 50
Btu/hr/W 10.16
R410A
OUTDOOR CAP. TUBE
AUTO LOUVER (UP& DOWN) & GRILLE (LEFT & RIGHT)
WIRELESS REMOTE CONTROL OR WIRED CONTROLLER (OPTIONAL)
l/s / CFM 316 / 670
l/s / CFM 297 / 630
l/s / CFM 236 / 500
dBA 49 / 47 / 45
mm/in 360 / 14.2
mm/in 1200 / 47.2
mm/in 200 / 7.9
mm/in 420 / 16.5
mm/in 1267 / 49.9
mm/in 260 / 10.2
kg/lb 17 / 37.48
mm/in 20 / 0.79
kg/lb 1.80 / 3.97
MODELINDOOR UNIT
WIRELESS
WIRED
OUTDOOR UNIT
NOMINAL CAPACITY
SENSIBLE HEAT FACTOR
NOMINAL TOTAL INPUT POWER
NOMINAL RUNNING CURRENT
POWER SOURCE
EER
REFRIGERANT TYPE
REFRIGERANT CONTROL (EXPANSION DEVICE)
IND
OO
R U
NIT
CONTROLAIR DISCHARGE
OPERATION
AIR FLOW
HIGH
MEDIUM
LOW
SOUND PRESSURE LEVEL (H/M/L)
UNITDIMENSION
HEIGHT
WIDTH
DEPTH
PACKINGDIMENSION
HEIGHT
WIDTH
DEPTH
UNIT WEIGHT
CONDENSATE DRAIN SIZE
REFRIGERANT CHARGE
1) DUE TO OUR POLICY OF INNOVATION, ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO INTERNATIONAL STANDARDS SUCH AS ISO 5151 AND AHRI 210/240. 3) NOMINAL COOLING CAPACITY ARE BASED ON THE CONDITIONS BELOW : COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR 4) SOUND PRESSURE LEVEL ARE MEASURED IN OYLM R&D SOUND ROOM. SOMEHOW DURING ACTUAL OPERATION, THE RESULT WILL BE HIGHER AS A RESULT OF AMBIENT CONDITION.
CROSS FLOW FAN
1
ACRYLO NITRILE STYRENE
DIRECT
mm/ in 106 / 4.17
mm/ in 950 / 37.4
INDUCTION
1
IP24
CLASS B
V / Ph / Hz 220 - 240 / 1 / 50
W 71
A 0.3
W
RPM
40
4130012001080
DIAMETER
MOTOR OUTPUT
FAN
TYPE
QUANTITY
MATERIAL
DRIVE
LENGTH
FAN MOTOR
TYPE
QUANTITY
INDEX OF PROTECTION (IP)
INSULATION GRADE
POWER SOURCE
RATED INPUT POWER
RATED RUNNING CURRENT
POLES
SPEED
SEAMLESS INNER GROOVE COPPER
mm / in 7.0 / 0.276
mm / in 0.28 / 0.011
ALUMINIUM
mm/ in 0.11 / 0.0043
0.30 / 3.23
2
18
MATERIAL
THICKNESS
FACE AREA
ROW
COIL
TUBE
MATERIAL
HIGHMEDIUM
LOW
DIAMETER
THICKNESS
FIN
FIN PER INCH
m² / ft²
SARANETpc 3
mm / in 330 / 13.0mm / in 317 / 12.4mm / in 1.8 / 0.07
SIZELENGTHWIDTHTHICKNESS
AIR QUALITY FILTER
TYPEQUANTITY
MATERIAL PLASTICCASING
Downloaded from www.Manualslib.com manuals search engine
12
TM-F
T-04
15-B
Specifications (R410A) - Continued
PROPELLER
1
ASG20
DIRECT
455 / 17.9
INDUCTION
1
IP23
CLASS F
V / Ph / Hz 220 -240 / 1 / 50
W 124
A 0.54
W
RPM
66
874
6
SCROLL
FV50S
cm³ / fl. Oz. 1130 / 38
CLASS E
V / Ph / Hz 220 -240 / 1 / 50
µF 45.0
W 2365
A 11.36
A 63
COPPER
mm / in 7 / 0.28
mm / in 0.23 / 0.009
ALUMINIUM
mm / in 0.11 / 0.0043
m² / ft² 0.61 / 6.58
2
18
MATERIAL GALVANISED STEEL
MODELWIRELESS
INDOOR UNITWIRED
OUTDOOR UNIT
DIAMETER
RATED INPUT POWER
RATED RUNNING CURRENT
MOTOR OUTPUT
POLES
SPEED
FAN
TYPE
QUANTITY
MATERIAL
DRIVE
CAPACITOR
RATED INPUT POWER
RATED RUNNING CURRENT
LOCKED ROTOR AMP.
FAN MOTOR
TYPE
QUANTITY
INDEX OF PROTECTION (IP)
INSULATION GRADE
POWER SOURCE
COMPRESSOR
TYPE
OIL TYPE
OIL AMOUNT
INSULATION GRADE
POWER SOURCE
FIN
MATERIAL
THICKNESS
FACE AREA
COIL
TUBE
MATERIAL
DIAMETER
THICKNESS
CASING
ROW
FIN PER INCH
1) DUE TO OUR POLICY OF INNOVATION, ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO INTERNATIONAL STANDARDS SUCH AS ISO 5151 AND AHRI 210/240. 3) NOMINAL COOLING CAPACITY ARE BASED ON THE CONDITIONS BELOW : COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR 4) SOUND PRESSURE LEVEL ARE MEASURED IN OYLM R&D SOUND ROOM. SOMEHOW DURING ACTUAL OPERATION, THE RESULT WILL BE HIGHER AS A RESULT OF AMBIENT CONDITION.
OU
TD
OO
R U
NIT
l/s / CFM 808 / 1712
dBA 54
mm/in 756 / 29.8
mm/in 855 / 33.7
mm/in 328 / 12.9
mm/in 793 / 31.2
mm/in 990 / 39.0
mm/in 416 / 16.4
kg/lb 57 / 25.6
FLARE VALVE
mm/in 9.52 / 3/8
mm/in 15.88 / 5/8
AIR FLOW
SOUND PRESSURE LEVEL
UNITDIMENSION
HEIGHT
WIDTH
DEPTH
PACKINGDIMENSION
HEIGHT
WIDTH
DEPTH
UNIT NET WEIGHT
PIPE CONNECTION
TYPE
SIZELIQUID
GAS
FTN311V1L
FTN311V1M
RN28CV1
Downloaded from www.Manualslib.com manuals search engine
13
TM-F
T-04
15-B
4.ApplicationInformation
Operating Range
Ensure the operating temperature is in allowable range.
Caution :The use of your air conditioneroutside the range of workingtemperature and humidity canresult in serious failure.
Cooling
DB: Dry bulb WB: Wet bulb
OU
TDO
OR
TEM
P. D
B (˚
C)
INDOOR TEMP. WB (˚C)
50
464340
30
20
10
010 14 15 19 20 23 25
Controller
DGS01
Operating Guide
1 Transmission Source • The source where the signal will be transmitted.
2 Signal Transmission Indication • Blink to confirm that the last setting has been transmitted to the unit.
3 “ON/OFF” Button • Press once to start the air conditioner unit. • Press again to stop the unit.
4 Fan speed selection • Press the button continuously will toggle the fan speed in the following order: Low � Med � High � Auto • Stop pressing when the desired fan speed appears on the display screen.
5 Operation mode • Press the MODE button to select the type of operating mode. • For cooling only unit, the available modes are: COOL ( ), DRY ( ) and FAN ( ).
6 Automatic air swing • Press the SWING ( ) button to activate the automatic air swing function. • To distribute the air to a specific direction, press the SWING ( ) button andwait until the louver move to the desired direction and press the button once again.
7 Turbo function • Press for fast cooling operation. • Fan speed turn to maximum speed. • Press again to deactivate the function. • Available under COOL and DRY modes only. • Any change of fan speed will deactivate this function.
TURBO QUIET
SLEEP
ON OFF
MODE
TIMER
CANCEL CANCELCLOCK
3
13
4
9
12
7
1
2
5
6
8
10
11
Downloaded from www.Manualslib.com manuals search engine
14
TM-F
T-04
15-B
4 Fan speed selection • Press the button continuously will toggle the fan speed in the following order: Low → Med → High → Auto • Stop pressing when the desired fan speed appears on the display screen.
5 Operation mode • Press the MODE button to select the type of operating mode. • For cooling only unit, the available modes are: COOL ( ), DRY ( ) and FAN ( ).
6 Automatic air swing • Press the SWING ( ) button to activate the automatic air swing function. • To distribute the air to a specific direction, press the SWING ( ) button and wait until the louver move to the desired direction and press the button once again.
7 Turbo function • Press for fast cooling operation. • Fan speed turn to maximum speed. • Press again to deactivate the function. • Available under COOL and DRY modes only. • Any change of fan speed will deactivate this function.
8 Quiet function • Press for quiet operation. • Fan speed turn to minimum speed. • Press again to deactivate the function. • Any change of fan speed will deactivate this function.
9 ON timer setting • Press the ON TIMER button will activate the on timer function. • Set the desired on time by pressing the ON TIMER button continuously. If the timer is set to 7.30am, the air conditioner will turn on at 7.30am sharp. • Press the CANCEL button to cancel the on timer setting.
10 OFF timer setting • Press the OFF TIMER button will activate the off timer function. • Set the desired off time by pressing the OFF TIMER button continuously. • Press the CANCEL button to cancel the off timer setting.
11 Clock time setting • Press and hold button to set the clock time.
12 Sleep mode setting • Press the button will activate the sleep mode function. • This is an energy saving option. When the unit is operating under cooling mode, the set temperature is increased by 0.5°C after 30 minutes, 1˚C after an hour, and 2˚C after 2 hours. • This function is available under COOL mode.
13 Temperature setting • To set the desired room temperature, press the or button to increase or decrease the set temperature. • The temperature setting range is from 16°C to 30°C. • Press both buttons and simultaneously to toggle from °C to °F setting.
Downloaded from www.Manualslib.com manuals search engine
15
TM-F
T-04
15-B
DSLM8
Operating Guide
MODETURBO
TIMEROVERRIDE
TIMER
ON OFFTIMER
SWING QUIET
SLEEP
14
5
6
23
1011
8
97
1 MODE Button Press the MODE button to switch operation from COOL, AUTO*, DRY*, FAN. Check the display to
see in which mode the control is set. *AUTO and DRY are available for selected models only.
2 TURBO Fan Speed Press the Turbo key once to activate Turbo fan speed. Turbo symbol will be shown. To disable Turbo
fan speed and back to previous fan speed, press the Turbo key once again. For the unit that does not have TURBO fan speed it will show high fan speed.
3 SWING Function Press SWING button to activate the swing function. Press it again to deactivate it.
4 QUIET Fan Speed Press the Quiet key once to activate Quiet fan speed. Quiet symbol will be shown. To disable Quiet
fan speed and back to previous fan speed, press the Quiet key once again. For the unit that does not have QUIET fan speed it will show low fan speed.
5 “�” or “�” Set Temperature Button Press the temperature button and set the temperature of your choice by pressing “�” or “�” button
once, temperature changes by 1°C or 1°F. The default temperature setting range is from 16°C to 30°C (60°F to 86°F). When the Option 20 - 30ºC is set, the temperature range limit is set to 20ºC to 30ºC (68°F to 86°F). Pressing both keys simultaneously will toggle the temperature setting between ºC and ºF.
6 SLEEP Function Press the SLEEP button to activate the sleep mode. DRY MODE and FAN MODE are not valid
during sleep function.
Downloaded from www.Manualslib.com manuals search engine
16
TM-F
T-04
15-B
7 “ON TIMER” and “OFF TIMER” The unit has 2-event timer, namely Timer 1 and Timer 2, each event has an ON TIMER and an OFF
TIMER. The key press activity for Timer ON and Timer OFF is shown on Table 1.1
Table 1.1: Timer ON and Timer OFF key press and event sequence.
All timers are event-triggered timers and can be overridden by the ON/OFF button and Override function.
Set Event 1 and Event 2 Timers
Process for Timer ON and Timer OFF is the same.1. Press and hold Timer ON/OFF key for 3 seconds to go into timer setting mode. (Icon ON 1 or OFF 1 will blink)2. Press UP or DOWN to select Timer 1 or Timer 2 to set. (‘1’ blinking indicate that Timer 1 is currently selected, ‘2’ blinking indicate that Timer 2 is currently selected)3. Press Timer ON/OFF key again to confirm. (Day will blink next)4. Press UP or DOWN to select the day.5. Press Timer ON/OFF key again to confirm the day. (Hour will blink next)4. Press UP or DOWN to change the hour.5. Press Timer ON/OFF key again to confirm the hour. (Minute will blink next)6. Press UP or DOWN to change the minute.7. Press Timer ON/OFF key again to confirm the minute.
Each timer (Timer 1 ON or Timer 1 OFF or Timer 2 ON or Timer 2 OFF) will only be set separately after all 7 steps, if there is no key operation for 5 seconds during setting the timer, it will automatically exits from setting mode and no changes will be made.
ON/OFF timer will be checked every 1 minute.It is not advisable to set ON TIMER and OFF TIMER to have same values. Shall these occur, the effective timer will be treated with priority as stated in Table 1.2.Example:ON TMR 2 settings: DAY – TUE, TIMER – 5.00pmOFF TMR 1 settings: DAY – TUE, TIMER – 5.00pmOutcome when RTC reaches 5.00pm on TUE: - when unit is on, no respond. - when unit is off, unit will trigger to on.
Table 1.2: Timer Priority
ON Timer 1 ON Timer 2 OFF Timer 1 OFF Timer 2 Deactivated Deactivated Deactivated Deactivated Activated Deactivated Activated Deactivated Deactivated Activated Deactivated Activated Activated Activated Activated Activated
TIMER ON KEY TIMER OFF KEY
Priority Timer1 (Highest)
23
4 (Lowest)
ONTMR2OFFTMR2ONTMR1OFFTMR1
Upon IR reception, IR wireless remote controller will override ON TIMER 2 and OFF TIMER 2 settings.
Downloaded from www.Manualslib.com manuals search engine
17
TM-F
T-04
15-B
8 OVERRIDE Function Press the OVERRIDE key once will activate the override function for 1 hour. An indicator
“OVERRIDE 1” will show on the LCD. Press the same key again will increase the setting to 2 hours. An indicator “OVERRIDE 2” will be shown. Subsequent press will deactivate the override function. After the override timer is completed, the override function is deactivated and the logo is OFF. All other timers will be resumed.
9 FAN Speed Function Fan speed can be changed via pressing the FAN key: Low > Med > High > Auto > Low >
10 ON/OFF Button Starting Operation: - Press the ON/OFF button, the LCD will show full display and the unit is turned on. Stopping Operation: - Press the ON/OFF button, the LCD will show real time clock only and the unit is turn off.
11 Real-time Clock (RTC) Display RTC is shown on screen during the unit ON or OFF except for power failure or error code.
Set RTC Setting 1. Press RTC key one time will activate RTC setting mode. (Day will blink) 2. Press UP or DOWN to select the day. 3. Press RTC again to confi rm the day. (Hour will blink next) 4. Press UP or DOWN to change the hour. 5. Press RTC again to confi rm the hour. (Minute will blink next) 6. Press UP or DOWN to change the minute. 7. Press RTC again to confi rm the minute. RTC will only be set after all 7 steps, if there is no key operation for 5 seconds during setting the
RTC, it will automatically exits from setting mode and no changes will be made on the setting.
12 Hardware Setting The unit has 4 jumpers option to control the board function. Table 2.0: Summary of Hardware Settings
OPTION
Set Temp. Range
TURBO_QUIET
Reserved
Reserved
With Jumper
Set Temp. Range from 20˚C-30˚C
Reserved
Reserved
Without Jumper
Set Temp. Range from 16˚C-30˚C(Default)
Enable turbo and quiet fan speed
Reserved
Reserved
Disable turbo and quiet fan speed(Default)
Wired Remote Control (Universal Board)Cooling
Error Code at 7 Segment Display Operation / Faulty Indication Blink E1 Room sensor contact open / short Blink E2 Indoor coil sensor contact open Blink E3 Outdoor coil sensor contact open
Blink E4 Compressor overload/ Indoor coil sensor short/Outdoor coil sensor short
Blink E5 Gas leak Blink E6 Pump faulty
Downloaded from www.Manualslib.com manuals search engine
18
TM-F
T-04
15-B
5.Installations
Installation GuidelineSafety Precautions
WARNING
CAUTIONPlease take note of the following important points when installing.
If gas leaks and accumulates around the unit, it may cause fire ignition.
Ensure that drainage piping is connected properly.If the drainage piping is not connected properly, it may cause water leakage which will dampen the furniture.
Do not overcharge the unit.
This unit is factory pre-charged. Overcharge will cause over-current or damage to the compressor.
Ensure that the unit’s panel is closed after service or installation.
Unsecured panels will cause the unit to operate noisily.
Sharp edges and coil surfaces are potential locations which may cause injury hazards.Avoid from being in contact with these places. Before turning off the power supply, set the remote controller’s ON/OFF switch to the “OFF” positionto prevent the nuisance tripping of the unit. If this is not done, the unit’s fans will start turning automatically when power resumes, posing a hazard to service personnel or the user. Do not operate any heating apparatus too close to the air conditioner unit. This may cause the plastic panel to melt or deform as a result of the excessive heat. Ensure the color of wires of the outdoor unit and the terminal markings are same to the indoors respectively.
IMPORTANT : DO NOT INSTALL OR USE THE AIR CONDITIONER UNIT IN A LAUNDRY ROOM.Do not use joined and twisted wires for incoming power supply.
Do not install the unit where leakage of flammable gas may occur. •
•
•
•
•
•
•
•
••
NOTICE
• Installation and maintenance should be performed by qualified persons who are familiar with local code and regulation, and experienced with this type of appliance.• All field wiring must be installed in accordance with the national wiring regulation.• Ensure that the rated voltage of the unit corresponds to that of the name plate before commencing wiring work according to the wiring diagram.• The unit must be GROUNDED to prevent possible hazard due to insulation failure.• All electrical wiring must not touch the refrigerant piping or any moving parts of the fan motors.• Confirm that the unit has been switched OFF before installing or servicing the unit.• Disconnect from the main power supply before servicing the air conditioner unit.• DO NOT pull out the power cord when the power is ON. This may cause serious electrical shocks which may result in fire hazards.• Keep the indoor and outdoor units, power cable and transmission wiring, at least 1m from TVs and radios, to prevent distorted pictures and static. {Depending on the type and source of the electrical waves, static may be heard even when more than 1m away}.
Disposal requirementsYour air conditioning product is marked with this symbol. This means that electrical and electronic products shall not be mixed with unsorted household waste.Do not try to dismantle the system yourself: the dismantling of the air conditioning system, treatment of the refrigerant, of oil and of other parts must be done by a qualified installer in accordance with relevant local and national legislation. Air conditioners must be treated at a specialized treatment facility for re-use, recycling and recovery. By ensuring this product is disposed of correctly, you will help to prevent potential negative consequences for the environment and human health. Please contact the installer or local authority for more information.Batteries must be removed from the remote controller and disposed of separately in accordance with relevant local and national legislation.
Downloaded from www.Manualslib.com manuals search engine
19
TM-F
T-04
15-B
Installation Diagram
Caution• Before installing the unit, ensure that the power supply matches the power requirement of the air conditioner.
Installation Of The Outdoor Unit
Installation Clearances
The outdoor unit must be installed in such a way, so as to prevent short circuit of the hot discharged air or obstruction to the smooth air flow. Please follow the installation clearances shown in the figure. Select the coolest possible place where intake air temperature is not greater than the outside air temperature (please refer operating range).
Note: If there is any obstacle higher than 2m, or if there is any obstruction at the upper part of the unit, please allow more space than the figure indicated in the above table.
Front panel
50mm or more from walls (on both sides)
75mm or more from ceiling
M4 x 12LAir filter
Service lid■ Opening service lid Service lid is opening/
closing type.■ Opening method dil ecivres eht evomeR )1
screws. dil ecivres eht tuo lluP )2
diagonally down in the direction of the arrow.
3) Pull down.
500mm from wall
Indoor unit
Outdoor unit
Caulk pipe hole gap with putty.
Cut thermal insulation pipe to an appropriate length and wrap it with tape, making sure that no gap is left in the insulation pipe’s cut line.
Wrap the insulation pipe with the finishing tape from bottom to top.
Ret
urn
air
Dis
char
ge a
ir
A
Obs
tacl
e
Obs
tacl
e
B
Obs
tacl
e
Ret
urn
air
Ser
vice
acc
ess
DC
Obs
tacl
e
Dimension A B C D
Minimum Distance, mm (in)
300(11.8)
1000(39.4)
300(11.8)
500(19.7)
Downloaded from www.Manualslib.com manuals search engine
20
TM-F
T-04
15-B
Air flow (Indoor)
min
. 75
(Spa
ce fo
r pe
rfor
man
ce)
Required space
All dimensions are in mm
min. 50
(Space for maintenance)
min. 50
(Space for maintenance)
Right-Side, Right-Back or Right-Bottom Piping
Right-back piping
Bind coolant pipe and drain hose together with insulating tape.
Right-bottom piping
Remove pipe port cover here for right-bottom piping
Right-side piping
Remove pipe port cover here for right-side piping
Remove pipe port cover here for left-bottom piping
Remove pipe port cover here for left-side piping
Left-back piping
Left-bottom piping
Left-Side, Left-Back or Left-Bottom Piping
Left-side piping
Installation Of The Indoor Unit
The indoor unit must be installed in such a way so as to prevent short circuit of the cool discharged air with the hot return air. Please follow the installation clearance shown in the figure. Do not place the indoor unit where there could be direct sunlight shining on it. Also, this location must be suitable for piping and drainage, and be away from doors or windows.
The refrigerant piping can be routed to the unit in a number of ways (left or right from the back of the unit), by using the cut-out holes on the casing of the unit (see figure). Bend the pipes carefully to the required position in order to align it with the holes. For the side and bottom out, hold the bottom of the piping and then position it to the required direction (see figure). The condensation drain hose can be taped to the pipes.
Mounting Installation Plate
Mounting plate
Mounting platefixing screw
FT10/15LV1L/M & FT10/15MV1I/JFTN10/15PV1L/M & FTN10/15MV1I9/J9
Mounting plate
Mounting platefixing screw
FT20/25LV1L/M & FT20/25MV1I/JFTN20/25PV1L/M & FTN20/25MV1I9/J9
FT311V1L/M & FTN311V1L/M
Installation plate
Marking-offline
Thread
Ensure that the wall is strong enough to withstand the weight of the unit. Otherwise, it is necessary to reinforce the wall with plates, beams or pillars. Use the level gauge for horizontal mounting, fix it with 5 suitable screws for FT10/15LV1L/M, FTN10/15PV1L/M & FT10/15MV1I/J, FTN10/15MV1I9/J9 and 7 suitable screws for FT20/25LV1L/M, FTN20/25PV1L/M & FT20/25MV1I/J, FTN20/25MV1I9/J9 and 4 suitable screws for FT311V1L/M & FTN311V1L/M. In case the rear piping draws out, drill a hole 65mm in diameter with a cone drill, slightly lower on the outside wall (see figure).
Downloaded from www.Manualslib.com manuals search engine
21
TM-F
T-04
15-B
Recommended Mounting Plate Retention Spots And Dimensions
Through the wallhole Ø 65mm
Recommended mounting plate retention spots (5 spots in all)
Use tape measure as shown.Position the end of a tape measureat166 184
42.2
288
42.2
Drain hosepositionGas pipe endLiquid pipe end
181.7 55.554.5 153.8 263 51.9800
45.9
45.9
All dimensions are in mm
FT10/15LV1L/M & FT10/15MV1I/JFTN10/15PV1L/M & FTN10/15MV1I9/J9
FT20/25LV1L/M, FT20/25MV1I/JFTN20/25PV1L/M & FTN20/25MV1I9/J9
All dimensions are in mm
Inside Outside
Hole with cone drill
CaulkingWall embedded pipe (Field supply)
Wall hole cover (Field supply)
Wall embedded pipe (Field supply)
Ø 65
Mounting plate
Interconnectingwires
Hang indoor unit’s hook here.
Wire guide
When stripping the ends of interconnecting wires in advance, bind right ends of wires with insulating tape.
Mounting plate
Clip
Mark (rear side)
Bottom frameFront grille
End dipped into water
Water leaking
Water leaking
Water leaking
Wrong Wrong Wrong
Drain
Water Drainage
Water retention
Correct
CAUTION• Do not install the unit at altitude over 2000m
for both indoor and outdoor.
Mount The Unit Onto The Installation PlateHook the indoor unit onto the upper portion of the installation plate (Engage the two hooks at the rear top of the indoor unit with the upper edge of the installation plate). Ensure that the hooks are properly seated on the installation plate by moving it to the left and right.
How To Attach The Indoor UnitHook the claws of the bottom frame to the mounting plate.
How To Remove The Indoor UnitPush up the marked area (at the lower part of the front grille) to release the claws.
Water Drainage PipingThe indoor drain pipe must be in a downward gradient for smooth drainage. Avoid situations that are likely to cause water to leak.
Recommended mounting plate retention spots (7 spots in all)
190 173
6131
0
61
Gas pipe endLiquid pipe end 4845580 1065
219
40 40
9145
Through the wall hole Ø 65mm
Drain hoseposition
Downloaded from www.Manualslib.com manuals search engine
22
TM-F
T-04
15-B
Outdoor Unit L E
Indoor Unit
Refrigerant PipingPiping Length & ElevationIf the pipe is too long, both the capacity and reliability of the unit will drop. As the number of bends increases, resistance to the flow of refrigerant system increases, thus lowering cooling capacity. As a result, the compressor may become defective. Always choose the shortest path and follow the recommendations as tabulated below:
ModelIndoor FT10LV1L/M
FT10MV1I/JR09CV1
FT15LV1L/MFT15MV1I/J
R15CV1
FT25LV1L/MFT25MV1I/J
R25CV1
FT311V1L/MFT20LV1L/MFT20MV1I/J
3
20
12 15 25
37
5
9.50 (3/8”)
6.35 (1/4”) 6.35 (1/4”) 9.50 (3/8”)
12.70 (1/2”) 15.88 (5/8”)
8
OutdoorMin. Allowable Length (L), m
Max. Allowable Length (L), m
Additional Charge of Refrigerant (g/m)
Max. Allowable Elevation (E), m
Gas Pipe Size, mm / (in)
Liquid Pipe Size, mm / (in)
Example: FT10LV1L & R09CV1 with 12m piping length, additional piping length is 4.5m. Thus,Additional charge = 4.5m x [20g/m] = 90 [g]* Be sure to add the proper amount of additional refrigerant. Failure to do so may result in reduced performance. Remark: The refrigerant pre-charged in the outdoor unit is for piping length up to 7.5m.
For R410A :
For R22:
Indoor Unit FTN10PV1L/MFTN10MV1I9/J9
RN10FV1
FTN15PV1L/MFTN15MV1I9/J9
RN15FV1
FTN20PV1L/MFTN20MV1I9/J9
RN20CV1
FTN25PV1L/MFTN25MV1I9/J9
RN25CV1
FTN311V1L/M
RN28CV1Outdoor Unit
25338
9.50 (3/8")9.50 (3/8")
Model
Liquid Pipe Size, mm / (in)
15
33020
12.70 (1/2")
6.35 ( 1/4")
15.88 (5/8")
2518Additional Charge of Refrigerant (g/m)
Min. Allowable Length (L),m
Gas Pipe Size, mm / (in)Max. Allowable Elevation (E), m
Max. Allowable Length (L), m
R18CV1 R20CV1 R31CV1
Downloaded from www.Manualslib.com manuals search engine
23
TM-F
T-04
15-B
Remove burr
Cutting copper tube
1/4t
Flared tubeFlare joint
Flare nutIndoor piping
Torque wrenchSpanar
Ø Tube, D A (mm)Inch mm Imperial
(Wing-nut Type)Rigid
(Clutch Type)1/4" 6.35 1.3 0.73/8" 9.52 1.6 1.01/2" 12.70 1.9 1.35/8" 15.88 2.2 1.73/4" 19.05 2.5 2.0
Pipe Size (mm/in)
Torque (Nm/ft-lb)
6.35 (1/4") 18 (13.3)9.52 (3/8") 42 (31.0)12.70 (1/2") 55 (40.6)15.88 (5/8") 65 (48.0)19.05 (3/4") 78 (57.6)
Figure D
Figure A
Copper tubeSwaging block A
D
Figure B
Figure C
Piping Works And Flaring Technique• Do not use contaminated or damaged copper
tubing. If any piping, evaporator or condenser had been exposed or had been opened for 15 seconds or more, the system must be vacuumed. Generally do not remove plastic, rubber plugs and brass nuts from the valves, fittings, tubing and coils until it is ready to connect suction or liquid line into valves or fittings.
• If any brazing work is required, ensure that nitrogen gas is passed through coil and joints while the brazing work is being done. This will eliminate soot formation on the inside wall of copper tubings.
• Cut the pipe stages by stages, advancing the blade of pipe cutter slowly. Extra force and a deep cut will cause more distortion of pipe and therefore extra burr. See Figure A.
• Remove burrs from cut edges of the pipes with remover. See Figure B. Hold the pipe on top position and burr remover at lower position to prevent metal chips from entering the pipe. This will avoid unevenness on the flare faces which will cause gas leak.
• Insert the flare nuts, mounted on the connection parts of both the indoor unit and outdoor unit, into the copper pipes.
• The exact length of pipe protruding from the top surface of the swaging block is determined by the flaring tool. See Figure C.
• Fix the pipe firmly on the swaging block. Match the centers of both the swaging block and the flaring punch, then tighten the flaring punch fully.
Piping Connection To The Units• Align the center of the piping and tighten the
flare nut sufficiently with fingers. See Figure D.• Finally, tighten the flare nut with torque wrench
until the wrench clicks.• When tightening the flare nut with the torque
wrench, ensure that the tightening direction follows the arrow indicated on the wrench.
• The refrigerant pipe connection are insulated by closed cell polyurethane.
Downloaded from www.Manualslib.com manuals search engine
24
TM-F
T-04
15-B
ModelFT311V1L/R31CV1FT311V1M/R31CV1
FTN311V1L/RN28CV1FTN311V1M/RN28CV1
Voltage range** 220-240V/1Ph/50Hz +
Power supply cable size* mm²Number of conductors
43
Interconnection cable size* mm²Number of conductors
Recommended time delay fuse A
2.54
25
!
FT311V1L
FT311V1M
R31CV1Outdoor
Indoor
Voltage range** 220-240V/1Ph/50Hz +
Power supply cable size* mm²Number of conductors
Interconnection cable size* mm²Number of conductors
Recommended time delay fuse A
2.53
2.53
20
FTN311V1L
FTN311V1M
RN28CV1Outdoor
IndoorModel
There must be an all pole disconnection in the supply mains with a contact separation of at least 3mm.
!There must be an all pole disconnection in the supply mains with a contact separation of at least 3mm.
COMP
N2
N1
L
COMP
N
COMP
N2
N1
LCOMP
R
S
N
L
N
L
Outdoor UnitTerminal Block
Power Supply Cable
Power Supply Cable
Indoor UnitTerminal Block
Outdoor UnitTerminal Block
Indoor UnitTerminal Block
Cooling Unit (single phase)
Model
Voltage range** 220-240V/1Ph/50Hz +
Power supply cable size* mm²Number of conductors
2.53
Interconnection cable size* mm²Number of conductors
Recommended time delay fuse A
2.53
20
1.53
1.53
15
FT10/15LV1L
FT10/15LV1M
FT10/15MV1I
FT10/15MV1J
FTN10/15PV1L
FTN10/15PV1M
FTN10/15MV1I9
FTN10/15MV1J9
FT20/25LV1L
FT20/25LV1M
FT20/25MV1I
FT20/25MV1J
FTN20/25PV1L
FTN20/25PV1M
FTN20/25MV1I9
FTN20/25MV1J9
Outdoor
COMP COMP
NN1
N
L
Indoor UnitTerminal Block Interconnection Cable
Outdoor UnitTerminal Block
Power Supply Cable Main Switch
N / L2
L/L1PowerSupply
Fuse / CircuitBreaker
!There must be an all poledisconnection in the supplymains with a contactseparation of at least 3mm.
Indoor
R09/15CV1RN10/15FV1
R18/20/25CV1RN20/25CV1
Downloaded from www.Manualslib.com manuals search engine
25
TM-F
T-04
15-B
Attach insulation sleeve
Round crimp-style terminalElectric wire
Connect wires of the same gauge to both side.
Do not connect wires of the same gauge to one side.
Do not connect wires of different gauges.
• All wires must be firmly connected.• Make sure all the wire do not touch the refrigerant piping, compressor or any moving parts.• The connecting wire between the indoor unit and the outdoor unit must be clamped by using
provided cord anchorage.• The power supply cord must be equivalent to H07RN-F which is the minimum requirement.• Make sure no external pressure is applied to the terminal connectors and wires.• Make sure all the covers are properly fixed to avoid any gap.• Use round crimp-style terminal for connecting wires to the power supply terminal block. Connect the
wires by matching to the indication on terminal block. (Refer to the wiring diagram attached on the unit).
• Used the correct screwdriver for terminal screws tightening. Unsuitable screwdrivers can damage the screw head.
• Over tightening can damage the terminal screws.• Do not connect wire of different gauge to same terminal.• Keep wiring in an orderly manner. Prevent the wiring from obstructing other parts and the terminal
box cover.
Downloaded from www.Manualslib.com manuals search engine
26
TM-F
T-04
15-B
Vacuuming is necessary to eliminate all moisture and air from the system.
Refrigerant Piping
Outdoor Unit 3 ways valve
Allen key
Service Port
Flare nut
HIGH PRESSURE GAUGE
GAUGE MANIFOLD
LOW PRESSURE GAUGE
HANDLE HI (ALWAYS CLOSED)
CHARGE HOSE
-760mmHg
HANDLE LO
CHARGE HOSE VACUUM PUMP ADAPTER FOR
COUNTER FLOW PREVENTION
CHECK
VALVE
LIQUID
VALVE
HIGH PRESSURE GAUGELOW PRESSURE GAUGE
GAUGE MANIFOLD-760mmHg
HANDLE LO HANDLE HI (ALWAYS CLOSED)
CHARGE HOSECHARGE HOSE
CHECK
VALVE
LIQUID
VALVEGAS VALVE
(3-WAY)
CONFIGURATION OF AIR PURGE BY CHARGING
GAS VALVE (3-WAY)
CONFIGURATION OF AIR PURGE BY CHARGING
Vacuuming And Charging
Vacuuming The Piping And The Indoor UnitExcept for the outdoor unit which is pre-charged with refrigerant, the indoor unit and the refriger-ant connection pipes must be air-purged because the air containing moisture that remains in the refrigerant cycle may cause malfunction of the compressor.• Remove the caps from the valve and the
service port.• Connect the center of the charging gauge to
the vacuum pump.• Connect the charging gauge to the service port
of the 2-way valve.• Start the vacuum pump. Evacuate for approxi-
mately 30 minuted. The evacuation time varies with different vacuum pump capacity. Confirm that the charging gauge needle has moved towards - 760mmHg.
Caution• If the gauge needle does not move to
-760mmHg, be sure to check for gas leaks (using the refrigerant detector) at fl are type connection of the indoor and outdoor unit and repair the leak before proceeding to the next step.
• Close the valve of the changing gauge and stop the vacuum pump.
• On the outdoor unit, open the suction valve (3 way) and liquid valve (2 way) (in anti-clockwise
direction) with 4mm key for hexagon sacked screw.
Charge OperationThis operation must be done by using a gas cylinder and a precise weighing machine. The additional charge is topped-up into the outdoor unit using the suction valve via the service port.
• Remove the service port cap.• Connect the low pressure side of the charging
gauge to the suction service port center of the cylinder tank and close the high pressure side of the gauge. Purge the air from the service hose.
• Start the air conditioner unit.
• Open the gas cylinder and low pressure charging valve.
• When the required refrigerant quantity is pumped into the unit, close the low pressure side and the gas cylinder valve.
• Disconnect the service hose from service port. Put back the service port cap.
Downloaded from www.Manualslib.com manuals search engine
27
TM-F
T-04
15-B
FT L/M, FTN P/M
Indicator Lights
ON to OFF 1 Long BeepOFF to ON 2 Short Beep Pump down/Cool force onOthers 1 Short Beep
IR Receiver
LED Indicator Lights for Cooling Unit
IR Receiver
ON/OFF
CoolTimerSleepON/OFF switch
IR Signal ReceiverWhen an infrared remote control operating signal has been transmitted, the signal receiver on the indoor unit will respond as below to confirm acceptance of the signal transmission.
Cooling UnitThe table shows the LED indicator lights for the air conditioner unit under normal operation and fault conditions. The LED indicator lights are located at the right-bottom of the air conditioner unit.
Downloaded from www.Manualslib.com manuals search engine
28
TM-F
T-04
15-B
Normal Operation /noitacidnI tluaF
––Cool Mode
Auto mode in Cooling operation
––Timer on
––no edom peelS
––no edom naF
––no edom yrD
Room air sensor contact
Loose / ShortCall your dealer Blink E1
Outdoor coil sensor open Call your dealer Blink E3
Indoor coil sensor open Call your dealer Blink E2
Compressor overload /
Indoor coil sensor short / Call your dealer Blink E4
outdoor coil sensor short
––noitarepo tsorfeD
5E knilBrelaed ruoy llaCkael saG
Hardware error (tact switch pin short) Call your dealer Blink E8
No feedback from indoor fan Call your dealer Blink E9
1 time
COOL(GREEN)
Green
Red
1 time
3 times
3 times
4 times
2 times
6 times
Green
ON ON or OFF Blinking
LED Indicator Lights : Normal Operation And Fault Conditions For CoolingUnit
ErrorCode
Action
– –
Downloaded from www.Manualslib.com manuals search engine
29
TM-F
T-04
15-B
LED Indicator Lights : Normal Operation And Fault Conditions
Operation / Fault Indication Action
Timer on
Sleep mode on
Dry mode on
Frost prevention
Sensor contact problem, compressor overloadprotection trip or gas leak
Indoor coil sensor contact loose / short
Room air sensor contact loose / short Call your dealer
Clean the filter and switch to high fan
-
-
-
- ON / - ON or OFF - Blinking
LED Indicator Lights
Power Dry Timer Sleep
/Continuously
once every 2 sec.
twice every 2 sec.
3 times every 2 sec.
Call your dealer
Call your dealer
FT311/FTN311
Downloaded from www.Manualslib.com manuals search engine
30
TM-F
T-04
15-B
Air Conditioner Unit Operation
In COOL, DRY and FAN mode
When stopoperation
Upper limit 55˚
Lower limit 85˚
Dry Mode• When the air humidity is high, the unit can operate in dry mode. Press <MODE> button and choose <DRY>.• If the room temperature is 2°C/3.6°F higher than the set temperature, the air conditioner will operate
under cooling mode until it reaches within the 2°C/3.6°F range of difference compared to the set temperature before it converts to dry mode.
• If the room temperature is within the 2°C/3.6°F range of difference compared to the set temperature, it will directly operate under dry mode.
• The unit will operate at LOW speed under dry mode.
Air Flow Control• For more effective air circulation, you can manually adjust the air discharge grille to the left or right.• During cool mode operation and dry mode operation, do not direct the air discharge louver down-
wards for too long. If operating continues in this way, condensation may occur on the louver, thus resulting indrippings.
Frost Prevention• When the air filter is dirty, the evaporating temperature will decrease and eventually cause frosting.• If the evaporating temperature reaches -1°C/33.8°F, the unit will trip.
Fan Speed And Rated Cooling Capacity• The rated cooling capacity is provided at the high fan speed.• The cooling capacity is lower when the unit is operating at MEDIUM and LOW fan speed.
Notes On Flaps And Louvers Angles• When “SWING button” is selected, the flaps swinging range depends on the operation mode. (See the figure.)
ATTENTION• Always use a remote controller to adjust the flaps angle. If you attempt to move it forcibly with hand
when it is swinging, the mechanism may be broken.• Be careful when adjusting the louvers. Inside the air outlet, a fan is rotating at a high speed.
Auto Random Re-start FunctionIf there is a power cut when the unit is operating, it will automatically resume the same operating mode when the power is restored.
Downloaded from www.Manualslib.com manuals search engine
31
TM-F
T-04
15-B
Special Precautions When Dealing With Refrigerant R410A Unit
(1) What is New Refrigerant R410A?R410A is a new HFC refrigerant which does not damage the ozone layer. The working pressure of this new refrigerant is 1.6 times higher than conventional refrigerant (R22), thus proper installation / servicing is essential.
(2) ComponentsMixture weight composition R32(50%) and R125(50%)
(3) Characteristic• R410A liquid and vapour components have different compositions when the fluid
evaporates of condenses. Hence, when leak occurs and only vapor leaks out, the composition of the refrigerang mixture left in the system will change and subsequently affect the system performance. DO NOT add new refrigerant to leaked system. It is recommended that the system should be evacuated thoroughly before recharging with R410A.
• When refrigerant R410A is used, the composition will differ depending on whether it is in gaseous or liquid phase. Hence when charging R410A, ensure that only liquid is being withdrawn from the cylinder or can. This is to make certain that only original composition of R410A is being charged into the system.
• PVE oil is used as lubricant for R410A compressor, which is different from the mineral oil used for R22 compressor. Extra precaution must be taken not to expose the R410A system too long to moist air.
(4) Check List Before Installation / Servicing• Tubing
Refrigerant R410A is more easily affected by dust of moisture compared with R22, make sure to temporarily cover the ends of the tubing prior to installation.
• Compressor oilNo additional charge of compressor oil is permitted.
• RefrigerantNo other refrigerant other that R410A
• Tools (size of service port is different from R22 system)Tools specifically for R410A only (must not be used for R22 or other refrigerant)i) Gauge manifold and charging hoseii) Gas leak detectoriii) Refrigerant cylinder/charging cylinderiv) Vacuum pump c/w adapterv) Flare toolsvi) Refrigerant recovery machine
(5) Handling and Installation GuildelinesLike R22 system, the handling and installation of R410A system are closely similar. All precautionary measures; such as ensuring no moisture, no dirt or chips in the system, clean brazing using nitrogen, and thorough leak check and vacuuming are equally important requirements.However, due to it hydroscopic PVE oil, additional precautions must be taken to ensure optimum and trouble free system operation.
(a) During installation or servicing, avoid prolong exposure of the internal part of the refrigerant system to moist air. Residual PVE oil in the piping and components can absorb moisture from the air.
(b) Ensure that the compressor is not exposed to open air for more than the recommended time specified by its manufacturer (typically less than 10 minutes). Removed the seal plugs only when the compressor is about to be brazed.
(c) The system should be thoroughly vacuumed to 1.0 Pa (700mmHg) or lower. This vacuuming level is more stringent than R22 system so as to ensure no incompressible gas and moisture in the system.
Downloaded from www.Manualslib.com manuals search engine
32
TM-F
T-04
15-B
(d) When charging R410A, ensure that only liquid is being withdrawn from the cylinder or can. This isto ensure that only the original composition of R410A is being delivered into the system. The liquid composition can be different from the vapour composition.
(e) Normally, the R410A cylinder or can is being equipped with a dip pipe for liquid withdrawal. However, if the dip pipe is not available, invert the cylinder or can so as to withdraw liquid from the valve at the bottom.
Downloaded from www.Manualslib.com manuals search engine
33
TM-F
T-04
15-B
6.WiringDiagrams
Indoor UnitModel : FT10/15LV1L, FT10/15LV1M FTN10/15PV1L, FTN10/15PV1M
Outdoor UnitModel : R09/15CV1 RN10/15FV1
WHITE WHITE
Downloaded from www.Manualslib.com manuals search engine
34
TM-F
T-04
15-B
WHITE
Indoor UnitModel : FT20/25LV1L, FT20/25LV1M FTN20/25PV1L, FTN20/25PV1M
Outdoor UnitModel : R18/20/25CV1, RN20/25CV1
Downloaded from www.Manualslib.com manuals search engine
35
TM-F
T-04
15-B
Indoor UnitModel : FT10/15MV1I, FT10/15MV1J FTN10/15MV1I9, FTN10/15MV1J9
Outdoor UnitModel : R09/15CV1 RN10/15FV1
WHITE WHITE
Downloaded from www.Manualslib.com manuals search engine
36
TM-F
T-04
15-B
WHITE
Indoor UnitModel : FT20/25MV1I, FT20/25MV1J FTN20/25MV1I9, FTN20/25MV1J9
Outdoor UnitModel : R18/20/25CV1 RN20/25CV1
Downloaded from www.Manualslib.com manuals search engine
37
TM-F
T-04
15-B
Outdoor UnitModel : R31CV1, RN28CV1
Indoor UnitModel : FT311V1L, FT311V1M FTN311V1L, FTN311V1M
Downloaded from www.Manualslib.com manuals search engine
38
TM-F
T-04
15-B
7.ServicingandMaintenance
Components Maintenance Procedures PeriodAir Filter
(Indoor Unit)1. Remove any dust adhering to the filter by using a vacuum cleaner
or wash in lukewarm water (below 40˚C) with a neutral cleaning detergent.
2. Rinse the filter well and dry before placing it back onto the unit.3. Note: Never use gasoline, volatile substances or chemicals to
clean the filter.
At least once every 2 weeks.More frequently if necessary.
Indoor Unit 1. Clean any dirt or dust on the grille or panel by wiping it wi th a soft cloth soaked in lukewarm water (below 40˚C) and a neutral detergent solution.
2. Note: Never use gasoline, volatile substances or chemicals to clean the indoor unit.
At least once every 2 weeks.More frequently if necessary.
Condense Drain Pan & Pipe
1. Check the cleanliness and clean it if necessary.2. Check the condensate water flow.
Every 3 months.
Indoor Fan Check if there is any abnormal noise. If necessary.Indoor / Outdoor
Coil1. Check and remove the dirt between the fins.2. Check and remove any obstacles which hinder air flow through the
indoor or outdoor.
Every month.
Power Supply 1. Check the running current and voltage for indoor and outdoor unit.2. Check the electrical wiring and tighten the wire onto the terminal
block if necessary.
Every 2 months.
Every year.
Compressor No maintenance needed if refrigerant circuit remains sealed. However, check for refrigerant leak at joint and fitting.
Every 6 months.
1. Open the front panel• Hold the panel at the recesses on the main unit
(2 recesses on right and left sides) and lift it until it stops.
2. Remove the front panel• While lifting the front panel further, slide it to the
right and pull it to the front side. The left rotating shaft is detached. Slide the right rotating shaft to the left and pull it to the front side to remove it.
3. Attach the front panel• Align the right and left rotating shafts of the front
panel with the grooves and push them all the way in.
• Gently close the front panel. (Push both ends and the center on the front panel.)
Rotatingshaft
Recess onmain unit
! CAUTION• Don’t touch the metal parts of the indoor unit. It may cause an injury.• When removing or attaching the front panel, use a robust and stable stool and watch your steps carefully.• When removing or attaching the front panel, support the panel securely with hand to prevent from it falling.• For cleansing, do no use hot water above 40°C, benzene, gasoline, thinner, nor other volatile oils, polishing
compound, scrubbing brushes, nor other hand stuff.• After cleaning, make sure that the front panel is securely fixed
Downloaded from www.Manualslib.com manuals search engine
39
TM-F
T-04
15-B
Caution!
Under normal circumstances, these outdoor units only require a check and cleaning of air intake coil surface once every 3 months. However, if a unit is installed in areas subjected to much oil mist and dust, the coils must be regularly cleaned by qualified Air Conditioner Service Technicians to ensure sufficient heat exchange and proper operation. Otherwise, the systems life span may be shortened.
Do not charge OXYGEN, ACETYLENE OR OTHER FLAMMABLE and poisonous gases into the unit when performing a leakage test or an airtight test. These gases could cause severe explosion and damage if exposed to high temperature and pressure.It is recommended that only nitrogen or refrigerant be charged when performing the leakage or airtight test.
Pre Start Up Maintenance(After Extended Shutdown)
• Inspect thoroughly and clean indoor and outdoor units.• Clean or replace air filters.• Clean condensates drainline.• Clean clogged indoor and outdoor coils.• Check fan imbalance before operation.• Tighten all wiring connections and panels.• Check for refrigerant leakage.
The design of the outdoor series allows servicing to be carried out easily. The removal of the top, front and side panels makes almost every part accessible.
Downloaded from www.Manualslib.com manuals search engine
40
TM-F
T-04
15-B
8.Troubleshooting
When a malfunction of the air conditioner unit is detected, immediately switch off the main power supplybefore proceeding with the following troubleshooting procedures.The following are common fault conditions and simple troubleshooting tips. If any other fault conditions whichare not listed occur, contact your nearest local dealer. DO NOT attempt to troubleshoot the unit by yourself.
snoitca evitcerroc / sesuac elbissoP snoitidnoc tluaF oN
1 The air conditioner unit will not resume after power failure.
• The auto restart function is not functioning. Please turn on the unit with the wireless / wired controller.
2 The compressor does not operate 3 minutes after the air conditioner unit is started.
• Protection against frequent starting. • Wait for 3 or 4 minutes for the compressor to start
operating by it self.
3 The airflow is too slow or room cannot be cooled sufficiently.
• The air filter is dirty. • The doors and windows are opened. • The air suction and discharge of both indoor and
outdoor units are clogged or blocked. • The regulated temperature or temperature setting
is not low enough.
4 Discharge airflow has bad odor. • Cigarettes, smoke particles, perfume and others, which might have adhered onto the coil, may cause odor.
• Contact your nearest dealer.
5 Condensation on the front air grille of the indoor unit.
• This is caused by air humidity after an extended period of operation.
• The set temperature is too low. Increase the temperature setting and operate the unit at high fan speed.
6 Water flowing out from the air conditioner. • Switch off the unit and contact your nearest dealer. This might be due to tilted installation.
7 Hissing airflow sound from the air conditioner unit during operation.
• Liquid refrigerant flowing into the evaporator coil.
8 The wireless controller display is dim. • The batteries are discharged. • The batteries are not correctly inserted. • The assembly is not good.
9 Compressor operates continuously. • Dirty air filter. Clean the air filter. • Temperature setting too low (cooling). Use higher
temperature setting.
10 No cool air comes out during cooling cycle. • Temperature setting too high (cooling). Use lower temperature setting.
Downloaded from www.Manualslib.com manuals search engine
41
TM-F
T-04
15-B
9.DimensionalData
Indoor Unit - FTL & FTM Series FTNP & FTNM Series
All dimensions are in mm
DimensionModel A B C D E F G H I J K L M
FT10/15LV1LFT10/15LV1MFTN10/15PV1LFTN10/15PV1M
800 288 166 184 42 46 55 56 154 182 263 52206
212
ATHE MARK SHOWS PIPING DIRECTION
LEFT
REAR
TOP VIEW
REAR
RIGHT
B
BOTTOM
LOUVER FRONT GRILLE FIXED SCREWS(INSIDE)
BOTTOM
FRONT VIEW
SIGNAL RECEIVER
INDOOR UNITON/OFF SWITCH
ROOM TEMPERATURE THERMISTOR (INSIDE)
B
NAME PLATE
TERMINALBLOCK WITHEARTH TERMINAL
C
SIDE VIEW
etalp gnitnuom dednemmoceR retention spots (5 spots in all)
D
Use tape measure as shown.Position the end of a tape measure at
BG
H JL M
A
K
F
I
G
F
E
Through the wallhole Ø 65mm
Drain hose position
Gas pipe endLiquid pipe end
INSTALLATION PLATE : FT10/15LV1L, FT10/15LV1M & FT10/15MV1L, FT10/15MV1J FTN10/15PV1L, FTN10/15PV1M & FTN10/15MV1I9, FTN10/15MV1J9
FT10/15MV1IFT10/15MV1JFTN10/15MV1I9FTN10/15MV1J9
800 288 216 166 184 42 46 55 56 154 182 263 52
Downloaded from www.Manualslib.com manuals search engine
42
TM-F
T-04
15-B
All dimensions are in mm
DimensionModel A B C D E F G H I J K L M
FT10/15LV1LFT10/15LV1MFTN10/15PV1LFTN10/15PV1M
800 288 104 141 30 46 55 56 153 181 207 52206
212
ALTERNATIVE INSTALLATION PLATE : FT10/15LV1L, FT10/15LV1M & FT10/15MV1L, FT10/15MV1J FTN10/15PV1L, FTN10/15PV1M & FTN10/15MV1I9, FTN10/15MV1J9
stops noitneter etalp gnitnuom dednemmoceR (5 spots in all)
Through the wallhole Ø 65mm
Drain hose position
Gas pipe endLiquid pipe end
E
FG
IKML
JH
FG
B
D
A
FT10/15MV1IFT10/15MV1JFTN10/15MV1I9FTN10/15MV1J9
800 288 216 104 141 30 46 55 56 153 181 207 52
Downloaded from www.Manualslib.com manuals search engine
43
TM-F
T-04
15-B
All dimensions are in mm
DimensionModel A B C D E F G H I J K L M
FT20/25LV1LFT20/25LV1MFTN20/25PV1LFTN20/25PV1M
FT20/25MV1IFT20/25MV1JFTN20/25MV1I9FTN20/25MV1J9
1065 310 190 173 61 40 45 48 91 219 580 45
1065 310 233 190 173 61 40 45 48 91 219 580 45
stopsnoitneteretalpgnitnuomdednemmoceR(7 spots in all)
D
BG
H JL M
A
K
F
I
GF
E
Through the wall hole Ø 65mm
Drain hose positionLiquid pipe end Gas pipe end
INSTALLATION PLATE: FT20/25LV1L, FT20/25LV1M & FT20/25MV1I, FT20/25MV1J FTN20/25PV1L, FTN20/25PV1M & FTN20/25MV1I9, FTN20/25MV1J9
Indoor UnitModel : FT311V1L, FT311V1M FTN311V1L, FTN311V1M
Note : Dimension in mm
200.
0
360.
0
327.
0
347.
0
224
228
Downloaded from www.Manualslib.com manuals search engine
44
TM-F
T-04
15-B
All dimensions are in mm
Outdoor UnitModel: R09/15CV1
DimensionModel A B C D E F G H I J K L M N O
R09CV1 600 475 245 418 177 35 93 81 83 55 398 101 97 17 22700 521 250 485 175 36 95 93 86 68 441 130 111 15 18R15CV1
KB
LL
CN
N
M30
A
DO
319
6580
C
G H
I J
EF
Downloaded from www.Manualslib.com manuals search engine
45
TM-F
T-04
15-B
All dimensions are in mm
Outdoor UnitModel: RN10/15FV1
DimensionModel A B C D E F G H I J K L M N O P
RN10/15FV1 550 658 51 11 273 16 14 470 96 299 94 60 14 133 8 8
H
NJ
GB CDE F
A
MK
L
P
O
I
Downloaded from www.Manualslib.com manuals search engine
46
TM-F
T-04
15-B
All dimensions are in mm
Outdoor UnitModel: R18/20/25/31CV1 RN20/25/28CV1
DimensionModel A
855 628 328 520 179 46 93 149 101 113 603 126 164 17 34
855 730 328 533 182 44 93 149 101 113 603 126 164 17 47
B C D E F G H I J K L M N O
R18/20CV1RN20/25CV1
R18/20CV1RN20/25CV1
R25/31CV1RN28CV1
R25/31CV1RN28CV1
DimensionModel P Q R S T
32 23 73 75
32 23 73 75
3
3
A
N
B
LL
M
C
O D
N
C
HG
FE
JI
P
Q
TS
R
K
Downloaded from www.Manualslib.com manuals search engine
47
TM-F
T-04
15-B
10.ExplodedView&PartList
Indoor UnitModel : FT10/15LV1L, FT10/15LV1M
NO DESCRIPTION NO DESCRIPTION
1 ASSY., FRONT GRILLEPANELAIR FILTERFRONT GRILLEASSY, CONTROL BOXASSY, SERVICE COVERASSY, PIPING FIXTUREMOTORMOTOR MOUNTING PLATE (1)MOTOR MOUNTING PLATE (2)BLOWER, CROSS FLOW
ASSY, INSTALLATION PLATERIGHT SIDE PANELDRIP PROOF COVERCLIP, COIL SENSORASSY, HEAT EXCHANGERASSY, DRAIN HOSEFAN BEARING VIBRATION ABSORBER SETASSY, DISCH, GRILLE HOR. BLADEASSY BOTTOM FRAME ASSY, PCB (WITH LAMP COVER)
12131415161718192021
23456789
1011
* DUE TO OUR POLICY OF INNOVATION, SOME SPECIFICATIONS MAY BE CHANGED WITHOUT NOTIFICATION.
Downloaded from www.Manualslib.com manuals search engine
48
TM-F
T-04
15-B
Indoor UnitModel : FTN10/15PV1L, FTN10/15PV1M
NO DESCRIPTION NO DESCRIPTION
1 ASSY., FRONT GRILLEPANELAIR FILTERFRONT GRILLEASSY, CONTROL BOXASSY, SERVICE COVERASSY, PIPING FIXTUREMOTORMOTOR MOUNTING PLATE (1)MOTOR MOUNTING PLATE (2)BLOWER, CROSS FLOW
12131415161718192021
ASSY, INSTALLATION PLATERIGHT SIDE PANELDRIP PROOF COVERCLIP, COIL SENSORASSY, HEAT EXCHANGERASSY, DRAIN HOSEFAN BEARING VIBRATION ABSORBER SETASSY, DISCH, GRILLE HOR. BLADEASSY BOTTOM FRAME ASSY, PCB (WITH LAMP COVER)
23456789
1011
* DUE TO OUR POLICY OF INNOVATION, SOME SPECIFICATIONS MAY BE CHANGED WITHOUT NOTIFICATION.
Downloaded from www.Manualslib.com manuals search engine
49
TM-F
T-04
15-B
Indoor UnitModel : FT10/15MV1I, FT10/15MV1J FTN10/15MV1I9, FTN10/15MV1J9
NO DESCRIPTION NO DESCRIPTION
1 ASSY., FRONT GRILLEPANELAIR FILTERFRONT GRILLEASSY, CONTROL BOXASSY, SERVICE COVERASSY, PIPING FIXTUREMOTORMOTOR MOUNTING PLATE (1)MOTOR MOUNTING PLATE (2)BLOWER, CROSS FLOW
ASSY, INSTALLATION PLATERIGHT SIDE PANELDRIP PROOF COVERCLIP, COIL SENSORASSY, HEAT EXCHANGERASSY, DRAIN HOSEFAN BEARING VIBRATION ABSORBER SETASSY, DISCH, GRILLE HOR. BLADEASSY BOTTOM FRAME ASSY, PCB (WITH LAMP COVER)PLASMA GENERATOR
1213141516171819202122
23456789
1011
* DUE TO OUR POLICY OF INNOVATION, SOME SPECIFICATIONS MAY BE CHANGED WITHOUT NOTIFICATION.
Downloaded from www.Manualslib.com manuals search engine
50
TM-F
T-04
15-B
NO DESCRIPTION NO DESCRIPTION
1 ASSY., CHASSISMOTORBLOWER, CROSS FLOWFAN BUSHMOTOR COVERASSY., INDOOR COILASSY., AIR DISCHARGE HOUSINGASSY., LOUVERPVC HOSE
ASSY., CONTROL BOXASSY., PCB (WITH LAMP COVER)CONTROL BOX COVERSERVICE COVERASSY., MOUNTING PLATEASSY., FRONT COVERFRONT COVERPANELFILTER
101112131415161718
23456789
* DUE TO OUR POLICY OF INNOVATION, SOME SPECIFICATIONS MAY BE CHANGED WITHOUT NOTIFICATION.
Indoor UnitModel : FT20/25LV1L, FT20/25LV1M
Downloaded from www.Manualslib.com manuals search engine
51
TM-F
T-04
15-B
NO DESCRIPTION NO DESCRIPTION
1 ASSY., CHASSISMOTORBLOWER, CROSS FLOWFAN BUSHMOTOR COVERASSY., INDOOR COILASSY., AIR DISCHARGE HOUSINGASSY., LOUVERPVC HOSE
101112131415161718
ASSY., CONTROL BOXASSY., PCB (WITH LAMP COVER)CONTROL BOX COVERSERVICE COVERASSY., MOUNTING PLATEASSY., FRONT COVERFRONT COVERPANELFILTER
23456789
* DUE TO OUR POLICY OF INNOVATION, SOME SPECIFICATIONS MAY BE CHANGED WITHOUT NOTIFICATION.
Indoor UnitModel : FTN20/25PV1L, FTN20/25PV1M
Downloaded from www.Manualslib.com manuals search engine
52
TM-F
T-04
15-B
NO DESCRIPTION NO DESCRIPTION
1 ASSY., CHASSISMOTORBLOWER, CROSS FLOWFAN BUSHMOTOR COVERASSY., INDOOR COILASSY., AIR DISCHARGE HOUSINGASSY., LOUVERPVC HOSEASSY., CONTROL BOX
11 ASSY., PCB (WITH LAMP COVER)CONTROL BOX COVERSERVICE COVERASSY., MOUNTING PLATEASSY., FRONT COVERFRONT COVERPANELFILTER
PLASMA GENERATOR
2 123 134 14567
15
8
16
9
1718
10
19
* DUE TO OUR POLICY OF INNOVATION, SOME SPECIFICATIONS MAY BE CHANGED WITHOUT NOTIFICATION.
19
Indoor UnitModel : FT20/25MV1I, FT20/25MV1J FTN20/25MV1I9, FTN20/25MV1J9
Downloaded from www.Manualslib.com manuals search engine
53
TM-F
T-04
15-B
Indoor UnitModel: FT311V1L, FT311V1M FTN311V1L, FTN311V1M
12 LED LIGHT BRACKET13 CONTROL BOX COVER14 ASSY. DRAIN HOSE15 AIR SWING MOTOR16 AIR LOUVER 17 ASSY. AIR DISCHARGE HOUSING 18 COIL SENSOR CLIP19 ASSY. FRONT COVER20 SARANET FILTER21 THERMISTOR HOLDER
1 ASSY. INSTALLATION BRACKET 2 ASSY. CHASSIS 3 PIPING CLAMP 4 FAN BUSH BRACKET 5 CROSS FLOW FAN 6 FAN BUSH 7 ASSY., INDOOR COIL 8 SERVICE PANEL 9 CONTROL MODULE 10 FAN MOTOR 11 ASSY, CONTROL BOX
NO DESCRIPTION NO DESCRIPTION
* DUE TO OUR POLICY OF INNOVATION, SOME SPECIFICATIONS MAY BE CHANGED WITHOUT NOTIFICATION.
1314151617181920
21
Downloaded from www.Manualslib.com manuals search engine
54
TM-F
T-04
15-B
Outdoor UnitModel : R09/15CV1
NO. DESCRIPTION NO. DESCRIPTION1 ASSY. BASE PAN
12 ASSY. FRONT PANEL2 ASSY. OUTDOOR COIL13 ASSY. CONTROL PANEL3 VALVE BRACKET14 ASSY. VALVE COVER4 COMPRESSOR15 ASSY. FRONT GRILLE16 PLASTIC HANDLE17 RUBBER GROMMET
5 ASSY. PARTITION6 ASSY. CAP TUBE7 BRACKET, FAN MOTOR8 FAN MOTOR PARTS NOT IN DIAGRAM
CAPACITOR, FAN MOTORCAPACITOR, COMPRESSOR
9 FAN BLADE10 LEFT PANEL
11 RIGHT PANEL
* DUE TO OUR POLICY OF INNOVATION, SOME SPECIFICATIONS MAY BE CHANGED WITHOUT NOTIFICATION.
Downloaded from www.Manualslib.com manuals search engine
55
TM-F
T-04
15-B
Outdoor UnitModel : RN10/15FV1
NO. DESCRIPTION NO. DESCRIPTION1 ASSY. OUTDOOR COIL
12 SUCTION PIPE
2 TOP PANEL
13 ASSY. CAP TUBE3 FAN MOTOR BRACKET
14 VALVE BRACKET4 ASSY PARTITION
15 ASSY. VALVE COVER16 ASSY. CONTROL PANEL17 RIGHT PANEL
5 FAN MOTOR6 FAN BLADE7 ASSY. FRONT GRILLE8 ASSY FRONT PANEL9 ASSY BASE PAN
10 COMPRESSOR11 DISCHARGE PIPE
* DUE TO OUR POLICY OF INNOVATION, SOME SPECIFICATIONS MAY BE CHANGED WITHOUT NOTIFICATION.
17
16
15
1413121110987
6
5
4
3
2 1
Downloaded from www.Manualslib.com manuals search engine
56
TM-F
T-04
15-B
Outdoor UnitModel : R18/20CV1, RN20/25CV1
NO. DESCRIPTION NO. DESCRIPTION1 ASSY., BASE PAN2 ASSY., OUTDOOR COIL3 MOTOR BRACKET
13 TERMINAL COVER PANEL
4 FAN MOTOR
14 ASSY., CONTROL PANEL
5 FAN BLADE
15 TOP PANEL
6 VALVE BRACKET 7 ASSY., FLARE VALVE 8 ASSY., FLARE VALVE 9 BLACK PANEL, RIGHT10
16 ASSY., FRONT GRILLE 17 PLASTIC HANDLE 18 ASSY., VALVE COVER 19 ASSY., CAPE TUBE 20 SUCTION PIPE 21 PARTITIONPARTS NOT IN THE DIAGRAMS CAPACITOR, FAN MOTOR CAPACITOR, COMPRESSOR
COMPRESSOR11 FRONT PANEL LEFT 12 SERVICE PANEL
* DUE TO OUR POLICY OF INNOVATION, SOME SPECIFICATIONS MAY BE CHANGED WITHOUT NOTIFICATION.
Downloaded from www.Manualslib.com manuals search engine
57
TM-F
T-04
15-B
Model : R25CV1, RN28CV1
1 ASSY. BASE PAN2 ASSY. OUTDOOR COIL3 MOTOR BRACKET4 FAN MOTOR5 FAN BLADE6 VALVE BRACKET7 PARTITION8 COMPRESSOR9 BACK PANEL, RIGHT10 SERVICE PANEL
NO DESCRIPTION NO DESCRIPTION11 FRONT PANEL, LEFT12 TOP PANEL13 ASSY. CONTROL PANEL14 TERMINAL CONTROL PANEL15 ASSY. VALVE COVER16 ASSY. FRONT GRILLE17 PLASTIC HANDLE, SIDE18 DISCHARGE PIPE19 SUCTION PIPE20 ASSY. CAP TUBE
* DUE TO OUR POLICY OF INNOVATION, SOME SPECIFICATIONS MAY BE CHANGED WITHOUT NOTIFICATION.
Downloaded from www.Manualslib.com manuals search engine
58
TM-F
T-04
15-B
Model : R31CV1
1 ASSY. BASE PAN2 ASSY. OUTDOOR COIL3 MOTOR BRACKET4 MOTOR5 FAN BLADE6 ASSY. VALVE BRACKET7 COMPRESSOR8 PANEL, SERVICE9 PANEL, PARTITION10 ASSY., VALVE COVER11 PANEL, RIGHT BACK
NO DESCRIPTION NO DESCRIPTION12 ASSY., PANEL FRONT LEFT13 ASSY, FRONT GRILLE14 ASSY , PANEL TOP15 PLASTIC, HANDLE FRONT 16 PLASTIC HANDLE17 PIPE, SUCTION18 PIPE, DISCHARGE19 ASSY. CAP TUBE20 FELT, COMPRESSOR21 ASSY., CONTROL PANEL
* DUE TO OUR POLICY OF INNOVATION, SOME SPECIFICATIONS MAY BE CHANGED WITHOUT NOTIFICATION.
21
Downloaded from www.Manualslib.com manuals search engine