EXCLUSIVE MAIN CONTROLS FOR MODELS 60H, 90H AND 190H
®
WALL CONTROLS
INTERMITTENT
MAXMIN
VC0080
®
L-T
RECIRCULATION
MAXMIN
VC0081
®
S-T
VC0039
MIN.
MAX.OFF
ME U ID
LESS HUMID
O
-30°C-22°F
EXCLUSIVE MAIN CONTROLS FOR GOLD AND HIGH EFFICIENCY SERIES UNITS
CONDENSATI0N CONTROLAA
AIR SUPPLY CONTROLLL
MIN.
MAX.
OFF
AIRAIREXCHANGECHHA
-20°C-4°F °
41°F
CO N E
SUMM
ER
VC0035
-20°C-4°F
-C
41°F
CONDENSATI0N CONTROLAA
AIR SUPPLY CONTROLLL
CONDENSATION CONTROLMAXIMUM SPEED
AIR EXCHANGE IN PROGRESS
MIN. MAX.
CONTINUOUSCONTINUOUS INTERMITTENTTINTERMITTENT
20 MINM .NNONON
40 MIN.MOFFOF
C M Z O E
SUMM
ER
VC0036
BASIC
PART # 40210ELECTRO
PART # 40220
PU
LL
PU
LL
LITE-TOUCH BRONZE
PART # 40270The light indicator color of this new wall control showsclearly in which operating mode the unit is.This push-button control has three functions:
•Intermittent (low speed exchange during 20 minutes, then stops during 40 minutes)
•Min (low speed)•Max (high speed)
BRONZE
PART # 40250This control adjust the air supply speed using the sliding button: OFF, MIN (low speed) and MAX (highspeed). Also, the maximum indoor humidity level for yourhouse is selected by the knob.
SIMPLE-TOUCH BRONZE
PART # 40290EXCLUSIVELY DESIGNED FOR 60H UNITS.The light indicator color of this new wall control showsclearly in which operating mode the unit is.This push-button control has three functions:
•Recirculation (stops exchanging with the outsideand recirculates inside air at high speed)
•Min (low speed)•Max (high speed)
OPERATION MODES
INTERMITTENT EXCHANGE (NOT AVAILABLE ON BASIC)This mode provides 20 minutes of air exchange per hour. If the dehumidistat orremote switch is activated, the ventilation rate will go to high speed until the conditionsare satisfied. This mode is ideal when the home is unoccupied. High speed ventilationwill be activated by the dehumidistat or remote switch.
LOW SPEED CONTINUOUS EXCHANGEIdeal for normal occupancy, this mode provides a continuous low rate of ventilation.High speed ventilation will be activated by the dehumidistat or by a remote switch.
HIGH SPEED CONTINUOUS EXCHANGEWhen occupancy increases, high speed ventilation will help to quickly reduce pollutants.
HUMIDITY CONTROL MAXIMUM SPEED (NOT AVAILABLE ON BASIC)
This light goes ON when the humidity control shifts the unit to high speed, in order toeliminate the excess humidity. When this light is ON, the setting of the AIR SUPPLYCONTROL can still be changed, but these changes will only take place when the CONDENSATION CONTROL MAXIMUM SPEED goes OFF.
20 MIN.ON
40 MIN.OFF
VQ0001
MIN.VQ0002
MAX.VQ0003
VQ0006
FEATURES
DEHUMIDISTATBy adjusting the interior relative humidity according to outside temperature, thehomeowner can control condensation on windows.
EXCHANGE INDICATORThis indicates that stale air is being exhausted and replaced by fresh air.
MAINTENANCE INDICATOR (NOT AVAILABLE ON BASIC)After 3 months of ventilation the INTERMITTENT EXCHANGE light (when flashing)will show the need to clean the filters and check for other routine maintenance. Onceservice is performed, the light is reprogrammed.
-20C-4F
-5C23F
5C41F
COMFORT ZONE
SUMM
ER
VQ0004
AIR EXCHANGEVQ0005
20 MIN.ON
40 MINOFF
VQ0001
Those 2 controls are compatible with the electronic board of both Gold and HighEfficiency Series, allowing to change from a Basic wall control to an Electro.The Electro control remembers which control strategy was in use even after a powerfailure. Even the date of the last service is maintained as a convenience to the homeowner.
20-MINUTE LIGHTED
PUSH BUTTON
PART # 1806110This timer allows the unit to provide 20minutes of high speed ventilation at thepush of a button, to exhaust rapidlyindoor stale air. Lighted when activated,up to five of them can be installed (eg: inbathrooms, kitchen, laundry room, etc.).(Available only for 60H, 90H and190H units).
60-MINUTE CRANK TIMER
PART # 00910This timer allows from 10 to 60 minutes ofhigh speed operation, to exhaust rapidlyindoor stale air. Can be installedd inbathrooms, kitchen or laundry room.
HUMIDITY CONTROL
PART # 200694The knob allows to adjust the maximumdesired indoor humidity level during fall,winter and spring. This control is graduatedin relative humidity percentage degrees.When a higher humidity level is detected,the unit turn on high speed until the situation is corrected.
AUXILIARY CONTROLS
VENTILATION
®
VC0040
OFF
10
20
30
40
50
60
TURNPAST
20
VC0017
FORT Z
F
RELL HU
70%
60%
50%
30%
25%
20%
HUMIDITYCONTROL
DURING FALL, WINTERFFAND SPRING, SET THE DIAL ACCORDING TO
THE DESIRED MAXIMUMINDOOR HUMIDITY LEVEL.
DURING SUMMER SETTHE DIAL TO THEOFF POSITION.
VC0038
20/40/60-MINUTE
PUSH BUTTON
PART # 03701This timer allows to turn on the unit onhigh speed during 20, 40 or 60 minutes,to exhaustl rapidly indoor stale air. Within2 seconds, press once for 20 minutes,twice for 40 minutes or three times for a60-minute activation. Press another timeto desactivate. (Available for Gold andHigh Efficiency Series units only).
WARRANTY
Subject to any applicable consumer protection legislation, the company warrants that all main and/orauxiliary vänEE controls are covered by the same warranty as the vänEE unit they are connected, providedvänEE control is under normal use and installation is in accordance with the provided installation instructions.
INSTALLATION
The vänEE controls are very easy to install! Using a 4-conductor telephone wire, perform the connection directly on the electronic board terminals. The following diagramsshow the terminal strips in the control box.
VC0041
20 min.
40 min.
60 min.
®
www.vanee-ventilation.ca 06/05 PRODUCT SHEET # 90221
®
550 Lemire blvd., Drummondville, QC, Canada J2C 7W9 - Tel.: 1 800 567-3855 Fax: 1 800 567-1715
60H UNITS - MAIN CONTROLS
60H UNITS - AUXILIARY CONTROLS
NO C NC I OC OL Y R G B
BGOC
MAIN WALL CONTROLLITE-TOUCH BRONZE
andSIMPLE TOUCH BRONZE
REAR VIEW
G BY
VE0101A
NO C NC I OC OL Y R G B
VE0103
COM FORT ZONE
OFF
% RELATIVEHUMIDITY
70%
60%
50%40%
30%
25%
20%
HUMIDITYCONTROL
MIN.
MAX.OFF
MORE HUMID
LESS HUMID
CO
MF
OR
TZ
ON
E
-30°C-22°F
-20°C-4°F
-5°C23°F
5°C+41°F+
NO C NC I OC OL Y R G B
20-MINUTED LIGHTED PUSH BUTTON (5 MAXIMUM)
60-MINUTECRANK TIMER
HUMIDITY CONTROL
VE0105A
CO M FORT Z ON E
OFF
% RELATIVE HUMIDITY
70%
60%
50%40%
30%
25%
20%
HUMIDITYCONTROL
DURING FALL, WINTER AND SPRING, SET THE DIAL ACCORDING TO
THE DESIRED MAXIMUM INDOOR HUMIDITY LEVEL.
DURING SUMMER SET THE DIAL TO THE OFF POSITION.
90H AND 190H UNITS - MAIN AND AUXILIARY CONTROLS
VE0008
CONNECTION FOR
BRONZE MAIN CONTROL
CONNECTION FOR AUXILIARY CONTROLS
(OL AND OC FOR TIMER AND HUMIDITY
CONTROL, OL, OC AND I FOR LIGHTED
PUSH BUTTON)
BG
OLOC
I
VE0116
CONNECTION FOR LITE-TOUCH BRONZE
MAIN CONTROL
BG
OLOC
I
CONNECTION FOR AUXILIARY CONTROLS
(OL AND OC FOR TIMER AND HUMIDITY
CONTROL, OL, OC AND I FOR LIGHTED
PUSH BUTTON)
VE0007
CONNECTION FOR BASIC
OR ELECTRO MAIN CONTROL
CONNECTION FOR FURNACE
INTERLOCK RELAY
CONNECTION FOR AUXILIARY CON-TROLS (OL AND OC FOR TIMER
AND HUMIDITY CONTROL, OL, OCAND I FOR PUSH BUTTON)
BGRYOLOC
IFF
GOLD AND HIGH EFFICIENCY SERIES UNITS - MAIN AND AUXILIARY CONTROLS
FURNACE INTERLOCK RELAY
(FOR GOLD AND HIGH EFFICIENCY SERIES UNITS ONLY)The furnace can be interlocked so it will run simultaneously with the ventilation system to ensure properdistribution of fresh air throughout the house.