Automated Workflow The Access workstation combines any Echo liquid handler with a modular robotics platform, offering a range of options for complementary devices and accessories. In a single compact system, the Echo liquid handler and two LightCycler ® 1536 systems are integrated with plate handling devices for sealing, peeling, centrifugation, bulk dispensing, barcode reading and labware management. The Access workstation includes Tempo™ automation control software, which instantly adds scheduling power to protocols created by Echo ® software applications. Instead of requiring complex scheduling logic, Tempo software automatically prioritizes plate handling, liquid handling, and data analysis requirements using a run setup wizard. In this configuration the Access workstation enables miniaturization of qPCR experiments and simplification of the entire workflow from cell lysate to qPCR results, for a walk-away high throughput qPCR solution. Figure 5. In one day, >10K reactions in 384-well assays or >40K reactions in 1536-well assays can be processed on an Access workstation (Labcyte Inc.) HT1080 cells were seeded in 96 wells of a 1536-well, Echo ® qualified tissue culture treated plate (Labcyte Inc.) at a concentration of 1000 cells/well and grown overnight. The media was removed, cells were washed with PBS and lysed with the RealTime ready Cell Lysis Buffer (4 µL/well, Roche) for 5 minutes at room temperature. The Echo liquid handler was used to transfer 5 nL lysate into a 1536 qPCR plate predispensed with the LC480 RNA Master Hydrolysis Probes (Roche) along with primer (500 nM) and UPL probe (200 nM) against the UPL reference gene assay for GAPDH (Roche), total reaction volume was 500 nL/well. The 96-well sample transfer was repeated 16 times to fill the 1536- well qPCR plate. Representative replicate statistics for two randomly chosen well replicates are shown in the table. Figure 6. Example well to well cell lysate dispense in 1536-well format using the Echo liquid handler. Summary Accelerated qPCR gene expression can be achieved by utilizing the RealTime ready Cell Lysis Kit from Roche. Increased throughput into 384- and 1536-well formats with volumes as low as 500 nL can be attained by incorporating the Echo liquid handler. Automated, miniaturized assay preparation for the entire workflow can be performed using the Access Workstation. One-Step Gene Expression Methods Results Figure 2. Potential qPCR workflows Figure 3A. Two-Step Protocol, 384-well, 3 µL volume Figure 3B. One-Step Protocol, 384-well, 3 µL volume Figure 2. The accelerated workflow for two-step RT-qPCR analysis of cell cultures (single-step cell lysis, fast cDNA synthesis combined with DNase treatment, qPCR) cuts in half the time required for gene-expression analysis as compared to the conventional workflow (multistep column-based RNA isolation, standard cDNA synthesis, qPCR). The combination of single step cell lysis with a one-step qPCR protocol, which incorporates the reverse transcription as part of the qPCR programming, significantly reduces hands-on time, reagent transfers, and overall time between cell cultures and gene expression data generation. Figure 3A and 3B. HT1080 cells were harvested at a final concentration of 4K cells/lysate reaction and lysed with the RealTime Ready Cell Lysis buffer (Roche) for 5 minutes at room temperature. The lysate was then treated two ways (see below) after which assays were run on a LightCycler ® 480 384 well real-time qPCR instrument (Roche): Figure 3A. Two-Step Protocolused as template for a cDNA synthesis reaction using Transcriptor Universal cDNA Master (Roche). The cDNA generated was then dispensed as template using the Echo 555 (Labcyte Inc.) into a 384-well qPCR plate predispensed with the LC480 Probes Master (Roche) along with primer (500 nM) and UPL probe (200 nM) against the UPL reference gene assay for GAPDH (Roche). Figure 3B. One-Step Protocolthe Echo 555 was used to dispense 10% (300 nL) cell lysate per total reaction volume of 3 µL into a 384-well qPCR plate predispensed with the LC480 RNA Master Hydrolysis Probes (Roche) along with primer (500 nM) and UPL probe (200 nM) against the UPL reference gene assay for GAPDH (Roche). Assay Transfer to LC1536 Results Figure 4A. Two-Step Protocol, 1536-well, 0.5 µL volume Figure 4B. One-Step Protocol, 1536-well, 0.5 µL volume Reaction set up for 1536-well qPCR was similar to that of the 384-well two-step and one-step workflows. The final reaction volume was 500 nL. Cell lysates were again added at 10% of the final reaction volume in the one-step protocol. Assays were run on a LightCycler ® 1536 real-time qPCR instrument (Roche). Introduction Quantitative reverse transcriptase PCR (RT-qPCR) offers unmatched accuracy and quantification of gene expression. Combining the one step RT-qPCR assay with a streamlined workflow upstream for generation of template from cellular material has enabled the use of higher density 384- and 1536-well microplates in high throughput methods employing fewer reagents. To successfully miniaturize RT-qPCR assay preparation for high-throughput workflows, one must overcome high risks for cross contamination, lower precision, and poor accuracy. The Access workstation combines the benefits of the Echo ® liquid handler with novel reagent chemistries and qPCR analysis into a single walk-away platform for high throughput qPCR. The Echo liquid handler overcomes the challenges of assay miniaturization by enabling tipless, touchless transfer of reagents to deliver the precision and accuracy needed for high quality qPCR. This poster examines the ability to automate qPCR assay preparation from lysis to analysis utilizing the RealTime ready Cell Lysis Kit and LightCycler ® 1536 system from Roche on the Access workstation—increasing throughput and reducing overall reaction volumes to as little as 500 nL. Echo liquid handler The Labcyte Echo 500 series revolutionizes liquid transfer by using acoustic energy to eject fluids. The Echo 500 series allows for assay miniaturization to previously unattainable volumes. Echo liquid handlers transfer 2.5 nL droplets repeatedly, so precision and accuracy are consistent over a larger volume range. Large volume transfer is achieved by transferring several hundred droplets per second. Transfer is non-contact and tipless, with increased cost savings from elimination of tip costs and washing fluids. Miniaturization with the Echo liquid handler retains high assay performance, allowing quantitative results at higher assay well densities. The Echo liquid handler can be used to transfer from any source well position to any destination well position. These can be simple fluids (media for growing cells, buffers, DMSO) or viscous solutions (lysis buffers, antibodies with glycerol, or transfection reagents). Walk away, nanoscale assay preparation for high throughput qPCR using the Access™ laboratory workstation and the Roche LightCycler ® 1536 System Celeste Glazer 1 , Rupal Cutting 2 , Tim Allison 1 , Randy Dyer 1 , Brad Nelson 1 , Joseph Barco 1 , Sammy Datwani 1 and Maria Sonntag 1 1 Labcyte Inc., Sunnyvale, CA, USA www.labcyte.com 2 Roche Applied Science, Indianapolis, IN, USA www.roche-applied-science.com Figure 1. The Echo liquid handler transfers fluid without contacting the sample. A transducer moves beneath the microplate and emits focused acoustic energy, which transfers droplets directly into an inverted destination. Cell seeding Cells seeded and grown in 384-well or 1536-well tissue culture treated Echo source plates. Exposed to compound or other treatment conditions. Cell lysis buffer addition RealTime ready Cell Lysis buffer addition by the Echo liquid handler Seamlessly scale from 384-well to 1536-well qPCR setup Transfer cell lysate directly from Echo source plates Addition of one step qPCR master mix, primers and probes with the Echo liquid handler Plate sealing and centrifugation Integrated PlateLoc with clear seal qPCR on LC1536 Walk-away capable for overnight runs

Walk away, nanoscale assay preparation for high …...conventional workflow (multistep column-based RNA isolation, standard cDNA synthesis, qPCR). The combination of single The combination

  • Upload
    others

  • View
    11

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Walk away, nanoscale assay preparation for high …...conventional workflow (multistep column-based RNA isolation, standard cDNA synthesis, qPCR). The combination of single The combination

Automated Workflow The Access workstation combines any Echo liquid handler with a modular robotics platform, offering a range of options for complementary devices and accessories. In a single compact system, the Echo liquid handler and two LightCycler® 1536 systems are integrated with plate handling devices for sealing, peeling, centrifugation, bulk dispensing, barcode reading and labware management. The Access workstation includes Tempo™ automation control software, which instantly adds scheduling power to protocols created by Echo® software applications. Instead of requiring complex scheduling logic, Tempo software automatically prioritizes plate handling, liquid handling, and data analysis requirements using a run setup wizard. In this configuration the Access workstation enables miniaturization of qPCR experiments and simplification of the entire workflow from cell lysate to qPCR results, for a walk-away high throughput qPCR solution. Figure 5. In one day, >10K reactions in 384-well assays or >40K reactions in 1536-well assays can be processed on an Access workstation (Labcyte Inc.) HT1080 cells were seeded in 96 wells of a 1536-well, Echo® qualified tissue culture treated plate (Labcyte Inc.) at a concentration of 1000 cells/well and grown overnight. The media was removed, cells were washed with PBS and lysed with the RealTime ready Cell Lysis Buffer (4 µL/well, Roche) for 5 minutes at room temperature. The Echo liquid handler was used to transfer 5 nL lysate into a 1536 qPCR plate predispensed with the LC480 RNA Master Hydrolysis Probes (Roche) along with primer (500 nM) and UPL probe (200 nM) against the UPL reference gene assay for GAPDH (Roche), total reaction volume was 500 nL/well. The 96-well sample transfer was repeated 16 times to fill the 1536-well qPCR plate. Representative replicate statistics for two randomly chosen well replicates are shown in the table. Figure 6. Example well to well cell lysate dispense in 1536-well format using the Echo liquid handler. Summary

• Accelerated qPCR gene expression can be achieved by utilizing

the RealTime ready Cell Lysis Kit from Roche. • Increased throughput into 384- and 1536-well formats with

volumes as low as 500 nL can be attained by incorporating the Echo liquid handler.

• Automated, miniaturized assay preparation for the entire workflow can be performed using the Access Workstation.

One-Step Gene Expression Methods Results Figure 2. Potential qPCR workflows Figure 3A. Two-Step Protocol, 384-well, 3 µL volume Figure 3B. One-Step Protocol, 384-well, 3 µL volume

Figure 2. The accelerated workflow for two-step RT-qPCR analysis of cell cultures (single-step cell lysis, fast cDNA synthesis combined with DNase treatment, qPCR) cuts in half the time required for gene-expression analysis as compared to the conventional workflow (multistep column-based RNA isolation, standard cDNA synthesis, qPCR). The combination of single step cell lysis with a one-step qPCR protocol, which incorporates the reverse transcription as part of the qPCR programming, significantly reduces hands-on time, reagent transfers, and overall time between cell cultures and gene expression data generation. Figure 3A and 3B. HT1080 cells were harvested at a final concentration of 4K cells/lysate reaction and lysed with the RealTime Ready Cell Lysis buffer (Roche) for 5 minutes at room temperature. The lysate was then treated two ways (see below) after which assays were run on a LightCycler® 480 384 well real-time qPCR instrument (Roche): Figure 3A. Two-Step Protocol―used as template for a cDNA synthesis reaction using Transcriptor Universal cDNA Master (Roche). The cDNA generated was then dispensed as template using the Echo 555 (Labcyte Inc.) into a 384-well qPCR plate predispensed with the LC480 Probes Master (Roche) along with primer (500 nM) and UPL probe (200 nM) against the UPL reference gene assay for GAPDH (Roche). Figure 3B. One-Step Protocol―the Echo 555 was used to dispense 10% (300 nL) cell lysate per total reaction volume of 3 µL into a 384-well qPCR plate predispensed with the LC480 RNA Master Hydrolysis Probes (Roche) along with primer (500 nM) and UPL probe (200 nM) against the UPL reference gene assay for GAPDH (Roche).

Assay Transfer to LC1536 Results Figure 4A. Two-Step Protocol, 1536-well, 0.5 µL volume Figure 4B. One-Step Protocol, 1536-well, 0.5 µL volume Reaction set up for 1536-well qPCR was similar to that of the 384-well two-step and one-step workflows. The final reaction volume was 500 nL. Cell lysates were again added at 10% of the final reaction volume in the one-step protocol. Assays were run on a LightCycler® 1536 real-time qPCR instrument (Roche).

Introduction

Quantitative reverse transcriptase PCR (RT-qPCR) offers unmatched accuracy and quantification of gene expression. Combining the one step RT-qPCR assay with a streamlined workflow upstream for generation of template from cellular material has enabled the use of higher density 384- and 1536-well microplates in high throughput methods employing fewer reagents. To successfully miniaturize RT-qPCR assay preparation for high-throughput workflows, one must overcome high risks for cross contamination, lower precision, and poor accuracy. The Access workstation combines the benefits of the Echo® liquid handler with novel reagent chemistries and qPCR analysis into a single walk-away platform for high throughput qPCR. The Echo liquid handler overcomes the challenges of assay miniaturization by enabling tipless, touchless transfer of reagents to deliver the precision and accuracy needed for high quality qPCR. This poster examines the ability to automate qPCR assay preparation from lysis to analysis utilizing the RealTime ready Cell Lysis Kit and LightCycler® 1536 system from Roche on the Access workstation—increasing throughput and reducing overall reaction volumes to as little as 500 nL.

Echo liquid handler

The Labcyte Echo 500 series revolutionizes liquid transfer by using acoustic energy to eject fluids. The Echo 500 series allows for assay miniaturization to previously unattainable volumes. Echo liquid handlers transfer 2.5 nL droplets repeatedly, so precision and accuracy are consistent over a larger volume range. Large volume transfer is achieved by transferring several hundred droplets per second. Transfer is non-contact and tipless, with increased cost savings from elimination of tip costs and washing fluids.

Miniaturization with the Echo liquid handler retains high assay performance, allowing quantitative results at higher assay well densities. The Echo liquid handler can be used to transfer from any source well position to any destination well position. These can be simple fluids (media for growing cells, buffers, DMSO) or viscous solutions (lysis buffers, antibodies with glycerol, or transfection reagents).

Walk away, nanoscale assay preparation for high throughput qPCR using the Access™ laboratory workstation and the Roche LightCycler® 1536 System

Celeste Glazer1, Rupal Cutting2, Tim Allison1, Randy Dyer1, Brad Nelson1, Joseph Barco1, Sammy Datwani1 and Maria Sonntag1 1 Labcyte Inc., Sunnyvale, CA, USA www.labcyte.com 2 Roche Applied Science, Indianapolis, IN, USA www.roche-applied-science.com

Figure 1. The Echo liquid handler transfers fluid without contacting the sample. A transducer moves beneath the microplate and emits focused acoustic energy, which transfers droplets directly into an inverted destination.

Cell seeding • Cells seeded and grown in 384-well or 1536-well

tissue culture treated Echo source plates. Exposed to compound or other treatment conditions.

Cell lysis buffer addition • RealTime ready Cell Lysis buffer addition by the Echo

liquid handler • Seamlessly scale from 384-well to 1536-well

qPCR setup • Transfer cell lysate directly from Echo source plates •Addition of one step qPCR master mix, primers and

probes with the Echo liquid handler

Plate sealing and centrifugation • Integrated PlateLoc with clear seal

qPCR on LC1536 ●Walk-away capable for overnight runs