154
VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual 7ZPNA4013

VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

Embed Size (px)

Citation preview

Page 1: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER

Maintenance Software

Instruction Manual

7ZPNA4013

Page 2: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)
Page 3: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

DOC No. 7ZPNA4014

RECORD OF REVISIONS

Rev Description Date

1.0 First edition 17-Oct.-06

Page 4: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

DOC No. 7ZPNA4014

Page 5: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

i DOC No. 7ZPNA4014

TABLE OF CONTENTS 1. Maintenance Software ................................................................................................................... 1 2. Maintenance Software starting ..................................................................................................... 3

2.1. Starting the Maintenance software ...............................................................................................................3 2.2. Quitting the Maintenance software...............................................................................................................5

3. Work item selection ....................................................................................................................... 7 3.1. Home screen................................................................................................................................................7 3.2. Work menu...................................................................................................................................................7

4. Installation, Setup and Check ....................................................................................................... 9 4.1. Selecting the installation...............................................................................................................................9 4.2. Receiving a configuration data and starting a diagnosis function...............................................................12 4.3. Sensor connection setup............................................................................................................................13 4.4. NSK connection setup................................................................................................................................26 4.5. Option unit (NCT-72/63) connection setup .................................................................................................31 4.6. Radar connection setup .............................................................................................................................52 4.7. Microphone connection setup ....................................................................................................................59 4.8. VHF connection setup................................................................................................................................64 4.9. VDR/S-VDR system setup .........................................................................................................................67 4.10. Capsule setup ............................................................................................................................................77 4.11. System Configuration File ..........................................................................................................................79

5. SYSTEM Screen ........................................................................................................................... 81 5.1. Common button on the SYSTEM screen ...................................................................................................82 5.2. Sensor section ...........................................................................................................................................83 5.3. Modified setup indicating............................................................................................................................84 5.4. Diagnosis function......................................................................................................................................85 5.5. System status window................................................................................................................................86 5.6. Operation button ........................................................................................................................................88 5.7. File menu ...................................................................................................................................................88

6. EVENT Monitor ............................................................................................................................. 89 6.1. Starting.......................................................................................................................................................89 6.2. Modification of EVENT list display..............................................................................................................91 6.3. EVENT log file open...................................................................................................................................94 6.4. EVENT log file save ...................................................................................................................................94 6.5. EVENT monitor record ...............................................................................................................................95

7. Real time Monitor (Menu) ............................................................................................................ 97 7.1. Starting.......................................................................................................................................................97 7.2. NMEA monitor ............................................................................................................................................98 7.3. Audio monitor ...........................................................................................................................................101 7.4. Radar monitor ..........................................................................................................................................102 7.5. Dry Contact monitor .................................................................................................................................103

8. System Status Display............................................................................................................... 107 8.1. Starting.....................................................................................................................................................107 8.2. System status display Window.................................................................................................................107 8.3. Start System status display ......................................................................................................................109 8.4. Diagnosis lamp of orange in normal operation.........................................................................................109 8.5. System status data file ............................................................................................................................. 110

9. Functions of Menu ......................................................................................................................111 9.1. Menu table ............................................................................................................................................... 111 9.2. Control ..................................................................................................................................................... 112 9.3. Convert (Recorded sensor data to text file).............................................................................................. 115 9.4. Config (Extract a setup file from a SysInfo.dat file) .................................................................................. 116 9.5. Error Code List ......................................................................................................................................... 117 9.6. Software Version display.......................................................................................................................... 118

Page 6: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

ii DOC No. 7ZPNA4014

10. Playback.......................................................................................................................................119

10.1. Starting..................................................................................................................................................... 119 10.2. Playback Software ...................................................................................................................................120 10.3. Check recorded data................................................................................................................................120

11. Frame Grabber Board (CKA-137) setup - FGB utility - ........................................................... 121 11.1. Check the Radar image specifications .....................................................................................................121 11.2. Setup & Capture.......................................................................................................................................121 11.3. Tuning ......................................................................................................................................................126

12. Option System setup ................................................................................................................. 131 12.1. Starting.....................................................................................................................................................131 12.2. Setup procedure.......................................................................................................................................132 12.3. Register Information.................................................................................................................................132 12.4. IP Address................................................................................................................................................132 12.5. Real Time Monitor section........................................................................................................................132

13. Report.......................................................................................................................................... 133 13.1. Starting.....................................................................................................................................................133

14. Program update.......................................................................................................................... 135 14.1. Program update of MCB, ARB and RMB .................................................................................................135 14.2. Program update of FGB ...........................................................................................................................137

15. Playback Software setup........................................................................................................... 139 15.1. How to play back downloaded data from the Capsule with Ethernet........................................................139 15.2. How to play back CF card data in VDR/S-VDR........................................................................................143 15.3. How to exit the Playback software ...........................................................................................................146

16. Installation .................................................................................................................................. 147 16.1. Uninstall the old version ...........................................................................................................................147 16.2. Installation procedure...............................................................................................................................147

Page 7: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

1. Maintenance SoftwareJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

1 DOC No. 7ZPNA4014

1. Maintenance Software

The maintenance software of JCY-1800/1850 is a PC-based application. It serves the purpose of configuring and inspecting the product at the factory. On board the ship, it helps users to install the JCY-1800/1850, settings, operational check, and to find the causes of malfunctions, if any.

1) Software name:

JCY1800-maint.exe

2) Language used for display:

English

3) Characters used for entry:

English one-byte characters only The number of characters that can be inputted is limited by each entry field. Any character over the maximum allowable number is rejected.

4) Installation of the maintenance software:

Use “setup.exe” for installing this software to the maintenance PC. Refer to Paragraph 16 for the installation method of this software.

5) OS:

Windows Xp

6) PC:

Minimum requirements for a lap top PC: •CPU: 1GHz or more •Memory: 512Mbytes or more •PCMCIA card slot: CF card as a data backup medium of VDR/S-VDR (attached a card adapter to the RCU)•Communication I/F: Ethernet (10/100Mbps) •Screen resolution : 1024×768 (XGA) or more •Display font : Small size font

7) Personal Firewall

In using the personal computer which enables the personal firewall function, use the maintenance software after disabling it.

Personal Firewall A personal firewall is a filtering facility of LAN communication link attached to OS (Windows Xp) and the software for a virus countermeasure.

When a personal firewall is enable. The VDR/S-VDR becomes impossible to communicate to the maintenance PC by a firewall function.

8) Other requirements for maintenance:

LAN cable (Builds in the RCU.) →Makes LAN connection from the Maintenance PC to the HUB unit of the RCU.

Page 8: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

1. Maintenance Software JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

2 DOC No. 7ZPNA4014

9)Connection port for the Maintenance PC

Connect the Maintenance PC to any port in “VDR-LAN”.

-------------- ABBREVIATIONS --------------- Some of the abbreviations commonly used in this manual are:

Abbreviations Name Type HVR/SVR Capsule NDH-316/317 RCU Recording Control Unit NDV-1800/1850 MCB Main Control Board CDJ-2304 FGB Frame Grabber Board CKA-137 ARB Audio Recording Board CHA-387 RMB Remote Maintenance Board CDJ-2143 OPU Operation Panel Unit NCG-169 DSC Digital Signal Converter (64CH/16CH) NCT-72/63 ACB Analog Signal Convert Board (DSC option) CEF-60

Page 9: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

2. Maintenance Software startingJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

3 DOC No. 7ZPNA4014

2. Maintenance Software starting

2.1. Starting the Maintenance software

2.1.1. Starting procedure 1) To load the maintenance software, double click the “Maintenance Software” icon on a desktop. 2) The maintenance Software starts and then the Login screen will appear.

2.1.2. Log in screen

Page 10: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

2. Maintenance Software starting JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4 DOC No. 7ZPNA4014

2.1.2.1. Selecting setup system (“Setup Equipment”)

Select a setup system from VDR, S-VDR or RMS.

2.1.2.2. Entering Worker, Company and Password (“Register Information”) 1) Register Information

Enter the worker information, which will be recorded onto the VDR/S-VDR. • Worker name • Company name

2) Password Enter a password, it is indicated with “*”. The password for field engineer is "jrcvdr" in a small letter.

2.1.2.3. Selecting Ethernet adapter The Maintenance software will detect an Ethernet adapter in a PC automatically. When the PC has more than one Ethernet adapter, select the adapter interface for connecting to the VDR/S-VDR with wired LAN.

Many of recent laptop PC has not only wire LAN but also a wireless LAN. Select the adapter for the wired LAN.

2.1.2.4. Adding IP address for VDR/S-VDR Check the IP address and the Subnet mask which are registered to Ethernet adapter. The IP address for VDR/S-VDR maintenance is added. (192.168.110.200)

The IP address added for VDR/S-VDR maintenance is deleted by shutting the maintenance software.

2.1.2.5. Login Click the [Next] button. When succeeding to login to the VDR/S-VDR, “HOME screen” will appear.

Page 11: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

2. Maintenance Software startingJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

5 DOC No. 7ZPNA4014

2.2. Quitting the Maintenance software

2.2.1. Check before exit

Confirm the following items before logout when the installation is finished 1. All Entry lamps shall light green in the System screen. 2. All Diagnosis lamps shall light green in the System screen. 3. Any error event shall not occur on real time Event monitor. 4. The downloaded data from the capsule should be played back rightly. 5. The copied data from the CF card should be played back rightly.

2.2.2. Quitting procedure Click the [Log out] button on the left side of each screen. The maintenance software is shut down after logging out from the VDR/S-VDR.

Page 12: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

2. Maintenance Software starting JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

6 DOC No. 7ZPNA4014

This page is intentionally left blank

Page 13: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

3. Work item selectionJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

7 DOC No. 7ZPNA4014

3. Work item selection

3.1. Home screen Operation button Work button

3.1.1. Selecting work item Click a work button on the Work section. The screen for the selected working item will appear.

3.2. Work menu

3.2.1. Installation Select for installing, setting and checking VDR/S-VDR system. • Shipment setup at the Mitaka plant • Installation setup on a ship • Check operation of the VDR/S-VDR • Annual inspection • Repair on a ship

Page 14: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

3. Work item selection JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

8 DOC No. 7ZPNA4014

3.2.2. Playback Select for checking recorded data on the VDR/S-VDR. The Playback software is loaded.

3.2.3. Option PC Select for setting up a real time monitor system. * It is only an enable/disable setup of outputting a real-time monitor data.

Refer to the "Real-time monitor system installation manual" for details.

3.2.4. Update Select for updating a program of each unit.

• MCB (Boot program/Application program) • ARB (Application program) • RMB (Boot program/Application program)

* Update of FGB program can be performed from the menu of a SYSTEM screen.

Page 15: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

9 DOC No. 7ZPNA4014

4. Installation, Setup and Check

4.1. Selecting the installation

4.1.1. Home screen [Installation] To configure the VDR/S-VDR, click the [Installation] button. The “SYSTEM” screen for system (VDR/S-VDR/RMS) selected at log-in will appear. ● JCY-1800

Page 16: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

10 DOC No. 7ZPNA4014

● JCY-1850

● Difference between the JCY-1800 and the KCY-1850 • The number of sensor connection channels •The capsule model

Page 17: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

11 DOC No. 7ZPNA4014

4.1.2. Operating procedure for installation Set up and check the VDR/S-VDR on the “SYSTEM” screen as following procedure.

The “Report” folder is created on the Desktop of PC automatically. Compress this folder, and upload the compressed files to the “Ship list” on the Marine service WEB.

Step Item Operation Contents See

1 Receive a system configuration data Receive button

The Maintenance software receives a system configuration data from the RCU. Click the [Receive] button. Setup information is displayed on the System screen after receiving.

4.2.1

2 Set each connection Check box for connectionEnter the check mark into the check box of each connection channel and each configuration unit with reference to an Installation drawing.

4.3.1 4.4.1 4.5.1 4.6.1 4.7.1 4.8.1

3 Set a detail information Detail button Click the Detail button of the section to set up. Select the connection channel in sensor section before clicking the Detail button.

4 Transmit a system configuration data to the RCU

Set button in each detail window

Click the Set button in the detail window after entering all data.

5 Set up the System Repeat the Step3 and Step4

Enter the detail information data of all section and each channel of the Sensor section.

4.3.2 4.4.2 4.5.2 4.6.2 4.7.2 4.8.2

6 Reboot the RCU Reboot button Click the Reboot button on the System screen. The RCU is operated by renewed system configuration data, after rebooting.

Check the diagnostic results

Diagnosis button and lamp

Click the Diagnosis button on the System screen. Maintenance software shows the diagnostic results by color of each lamp. Check the color of diagnostic lamp, green lamp means OK.

5

7

Receiving data Real time monitor Check a receiving data by the real time monitor. 7

8 Improve, if there is a problem. Return the STEP3

The red and yellow color of lamp means the problem of setup, wiring or connection equipments. Improve the problem shown by the Maintenance software. The orange color of lamp means under diagnosis.

9 Recorded data Playback Check a recorded data by the Playback software. 10

10 Complete the setup All diagnostic lamp of System screen Make all lamps green and complete a setup. 5

11 Make the report Report A report files are created. 13

Page 18: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

12 DOC No. 7ZPNA4014

4.2. Receiving a configuration data and starting a diagnosis function

4.2.1. Receiving a configuration data of RCU Start a maintenance operation from receiving a configuration data. 1) Click the [Receive] button. 2) Confirm the completion of reception with a progress bar.

4.2.2. Starting the diagnosis function The state of VDR/S-VDR system and OK/NG of receiving data can be displayed by the color of “Diagnosis” lamps. A diagnostic result is displayed as follows.

● (Green): OK ● (Red): NG ● (Orange): Under a diagnosis 1) Click the [Diagnosis] button. 2) Confirm that the color of [Diagnosis] button changes a green color. * When the [Diagnosis] button is clicked during operating a diagnosis function, it is stopped.

Page 19: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

13 DOC No. 7ZPNA4014

4.3. Sensor connection setup

4.3.1. Setting connection

Enable / Disable of each sensor connection can be set up. 1) Each channel

Enter a check mark into the check box of connected CH. Enable: [ ] (checked) Disable: [ ] (unchecked)

Opening detail window Check box

Selecting the object CH of set up

Caution) Remove the mark from the check box when sensor connection setup is changed (enable to disable) temporary. In not connecting, delete a setup data with reference to the 4.3.3.3th clause. If a setup data remains even if it removes a mark from a check box, a setup data for recording the same data may not be unable to be set to other CH.

4.3.2. Starting detail setup The detailed setup window of each channel is displayed.

1) Selecting CH Click a radio button of setting sensor channel. 2) Click the [Detail] button on Sensor section, a detail setup window is displayed.

Page 20: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

14 DOC No. 7ZPNA4014

4.3.3. Selecting a recording data

Select the connection equipment and recording data according to the following procedure. The initial value for receiving the data of the equipment chosen is set up automatically on the detail setting window.

4.3.3.1. In the case of new setting

Select a “recording item” from the pull-down menu. Click the [Next] button.

Select connected “equipment” from the pull-down menu.

Select the “Other”, when there is no appropriate item which should be set up Enter an appropriate data for connected equipment on a "Data" tab screen. Caution) In case of a recording data item to set up is not displayed:

Object data are registered into other channels. It is necessary to clear a setup of CH registered. Setting data are not cleared by connection disable. Refer to the following procedure for deleting setup data.

Page 21: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

15 DOC No. 7ZPNA4014

4.3.3.2. When setting data is changed

• In case of changing the detail setup data registered: Choose the “No” (Default) of radio button and click the [Next] button.

• In case of changing the selected “Recording item” and selected “Equipment”: Choose the “Yes” of radio button and click the [Next] button.

4.3.3.3. When registered setup data are deleted

Enter the check mark into the check box of lower "delete information", and click the [Next] button. A registered setup data is deleted. In the following cases, it is required to delete the setting data of CH which are not connected.

Example) a shipment setup is a default setting for recording a heading data from CH4 by NMEA.

Since the heading data is outputted with the step signal, it should be connected to CH33 (NSK). 1) Setup error If a setup data remains even if it removes a check mark from a check box of the CH4, a following error

dialog will be displayed at checking mark to the CH33.

2) Setup procedure Delete the setup data of the CH4 according to upper procedure. Enter the check mark into the check box of CH33. Enter setup data for receiving the heading data into detail window of CH33.

Page 22: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

16 DOC No. 7ZPNA4014

Selection table

Recording item Equipment ID Recording data Sentence ID

Date and Time ??ZDA ??RMC

??GGA ??GLL Ship's Position ??GNS ??RMCV

GPS(Main) 41

Local Geodetic Datum(DTM) ??DTM Date and Time ??ZDA ??RMC

??GGA Ship's Position ??GNS ??RMCV

GPS(Main+Sub) 71

Local Geodetic Datum(DTM) ??DTM Other ??ZDA ??RMC

??GGA Other ??GNS ??RMCV

Date & Time/Ship's

Position

GPS(Sub) 72

Other ??DTM Ship's Speed Speed Log 43 Ground/Water Speed ??VBW

Gyro Compass Ship's Heading ??HDT Ship's Heading

Magnetic Compass

44

Ship's Heading ??HDG

Echo Sounder(Bow) 47 Depth ??DPT

Other ??DPT

Depth

Echo Sounder(Stern) 59

Wind Speed and Direction Anemometer 48 Wind Speed and Direction ??MWV

Rudder Order, Manual ??HTD Autopilot 45

Rudder Response, Manual ??RSA Rudder Angle Indicator 46 Rudder Response, Manual ??RSA

Rudder Order/Response

ECDIS 51 Rudder Order, Automatic ??HTC M/E RPM Set Order(CPP order) ??PRC M/E Remote Control

System 50

M/E RPM Actual Response(CPP order) ??RPM

Engine Order/Response

Engine Telegraph 49 Telegraph Order Position ??ETL

Thruster 52 Thruster Response ??TRD Bow1 Thruster 53 Thruster Response ??TRD

Bow2 Thruster 54 Thruster Response ??TRD Stern1 Thruster 55 Thruster Response ??TRD

Thruster Order/Response

Stern2 Thruster 56 Thruster Response ??TRD Acceleration and Hull Stress

Hull Stress Monitor 57 Hull Stress ??HSS

Fire Door Status * Fire Door Status ??DOR

Watertight Door Panel * Watertight Door Status ??DOR Hull Door Controler * Hull Door Status ??DOR

Door Status

Ramp Way Indicator * Alarm Monitoring system *

Water Ingress Alarm System

*

Bilge Alarm Panel * Fire Detection System *

Main Alarms

Steering Gear * AIS VDO Data ??VDO

AIS VDM Data ??VDM Status Information ??TXT

AIS Data AIS 42

Main Alarm(ALR) ??ALR Radar Selection Radar(Main) 58 Radar Selection ??PJRC Other * Other

Page 23: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

17 DOC No. 7ZPNA4014

Recording item Equipment ID Recording data Sentence ID

DSC (CH13) 60 Dry Contact Data (CH13) ????? DSC (CH14) 61 Dry Contact Data (CH14) ????? DSC (CH15) 62 Dry Contact Data (CH15) ????? DSC (CH16) 63 Dry Contact Data (CH16) ?????

Dry Contact Data (CH13) ????? DSC+A/D (CH13) 64

A/D Convert Data (CH13) VRXDR Dry Contact Data (CH14) ????? DSC+A/D (CH14) 65 A/D Convert Data (CH14) VRXDR Dry Contact Data (CH15) ????? DSC+A/D (CH15) 66 A/D Convert Data (CH15) VRXDR Dry Contact Data (CH16) ????? DSC+A/D (CH16) 67 A/D Convert Data (CH16) VRXDR

NAV-IF (NCT-52A) 68 NAV-I/F Data(Option Unit) ANADAT

Option Unit

NAV-IF (NCT-**) 69 NAV-I/F Data(Option Unit) ANADAT

Page 24: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

18 DOC No. 7ZPNA4014

4.3.4. Detail setup window of sensor (standard)

4.3.4.1. Identification TAB screen

Set an identification data of connected equipment 1) Equipment

Enter the name of the connecting equipment. (GPS, Echo sounder, etc.) * When except “Other” is selected, a default equipment name is entered automatically.

2) Model Enter the model name of the connecting equipment.

3) Manufacturer Enter the name of the manufacturer of the connecting equipment.

4) Serial No. Enter the serial number of the connecting equipment.

* The old equipment by which the serial number is not displayed also exists. In that case, enter "unknown" into the Serial No. column.

Page 25: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

19 DOC No. 7ZPNA4014

4.3.4.2. Data TAB screen

Check the entry data, when initial values are entered as record item selected in pre-procedure. Change entry data, when required. Enter a setup data when “Other” is selected as record item in pre-procedure.

4.3.4.2.1. Type

Select the type of receiving sentences.

No. Type Connector Selectable CH Remark

1 NMEA General sensors CH01-CH32 NMEA 2 AIS AIS unit CH01-CH16 NMEA 3 DRY-CNT Digital signal converter unit (option) CH13-CH16 NCT-72/NCT-63 4 DCNT+A/D Equipment with built-in DSC

(Addition of the optional A/D converter board) CH13-CH16 NCT-72/NCT-63

(A/D built-in) 5 A/D Equipment with built-in DSC

(Addition of the optional A/D converter board) CH13-CH16 NCT-72/NCT-63

(A/D built-in) 6 NSK NSK unit (option) CH01-CH32 NCT-27B 7 NAV-I/F NAV-I/F unit (option) CH13-CH16 NCT-52A

Page 26: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

20 DOC No. 7ZPNA4014

4.3.4.2.2. Communication parameters and Sentence format

Set the communication parameter and Set the sentence format. Once the type is selected, this parameter is automatically set by default. There is no need to change this value.

TYPE NMEA AIS DRY-CNT DCNT+A/D A/D NAV-IF NSK Baud Rate 4800 38400 4800 4800 4800 19200 4800 Data Bits 8 8 8 8 8 8 8 Stop Bits 1 1 1 1 1 1 1 Parity None None None None None None None Checksum enable enable enable enable enable enable enable Header $ ! $ $ $ $ $ Delimiter 0D0A 0D0A 0D0A 0D0A 0D0A 0D0A 0D0A Max Length 82 82 82 82 82 82 82 Max Interval 15 15 315 15 15 15 15

1) Header Enter the header character.

“$” is entered in case of connecting to the general sensor units. In case of connecting to the AIS, enter “!” as the header character. When “!” is entered, the DAU receives the NMEA sentences with “$” and “!” as header. 2) Delimiter

Enter the delimiter in the form of codes. The delimiter is expressed as codes not as characters. “<CR><LF>“can be codified as “OD OA”.

3) Maximum sentence length

Set the maximum length of the data sentence. Any data sentence of which length exceeds this maximum sentence length is rejected and an error is reported. The maximum length of the NMEA sentence is 82Byte.

4) Maximum time interval of receiving

Set the maximum time interval of receiving. If the time taken to receive a data sentence exceeds this maximum time interval, the sentence is rejected and an error is reported. For example, suppose ZDA, DTM, and GGA are set to be received. If the time taken to receive all ZDA, DTM and GGA exceeds the maximum time interval, all the information is rejected and an error is reported.

Page 27: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

21 DOC No. 7ZPNA4014

4.3.4.2.3. Recording data

Whether a sentence is recorded in the VDR/S-VDR is determined by the sentence ID. Any sentence of which ID is different from the specified sentence ID is discarded and is not recorded in the VDR/S-VDR.

1) Recording item

Select record item from the pull-down menu. Select “Other”, when there is no corresponding entry.

2) Sentence ID

Select sentence ID from the pull-down menu. Enter a sentence ID, when there is no corresponding entry.

Type in 7 characters maximum, starting from the next to the header characters.

In case of NMEA sentence: The talker ID (2 characters) can be entered along with the sentence ID (3 characters). An uncertain character also can be entered using “?”. Enter as many characters as you like (up to 7 characters). At least, include the sentence ID (3 characters). Examples: setting sentence ID for filtering ZDA sentences of GPS. ( all OK )

▫ GPZDA ▫ GPZDA?? ▫ ??ZDA ▫ ??ZDA??

In case of option unit sentence: A/D : VRXDR DSC (NCT-72/63) : ? (Since all sentences are recorded, "?" is set up as a wildcard.)

3) Watch The NMEA sentence to record and the NMEA sentence to watch can be set up individually. Set the Watch function of each NMEA sentences to enable or disable. The VDR/S-VDR will generate the error alarm when the NMEA sentences set as “Enable” are not received within interval time. The VDR/S-VDR will not generate the error alarm when the NMEA sentences set as “Disable” are not received within interval time.

Enable: [ ] (checked) Disable: [ ] (unchecked)

When the NMEA sentence ID is registered, checks will be entered by a default.

In case of set to disable

Setting as “Disable” is effective when a sensor unit do not transmit some NMEA sentences periodically. Set as “Enable” to only the NMEA sentence received periodically.

Page 28: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

22 DOC No. 7ZPNA4014

4.3.4.3. Checking setup data Confirm that there is no blank in setting data. Defect in setting entry (Model, Serial number, etc.) as warning can be displayed to the

“Entry” lamp. ● (Green): All entries are inputted. ● (Yellow): The blank entry remains.

Look for a blank entry and input a setup data to blank entry.

4.3.4.4. Transmitting setup data Transmit the setup data to the RCU. • Transmit Click the [SET] button. • Cancel Click the [Close] button.

4.3.4.5. Real Time Monitor

Monitor the NMEA sentence data which is collected in the RCU on real time, and check the sentence specified by the installation drawings is collected correctly.

1) Procedures

START: Click the [Start] button. * Real time monitor is automatically started at the opening window. STOP: Click the [Stop] button.

2) Selecting the monitor data type. Click the radio button of data type (“RCV Data” /”REC Data”) to monitor.

● “RCV Data”: Monitors all data which the RCU receives.

The sentence data which is not recorded on the VDR/S-VDR is also displayed.

● “REC data”: Monitors the sentence data which is recorded in the VDR/S-VDR. The sentence which is not recorded is not displayed even if it has received. The monitor data is displayed by the sentence format currently recorded in the VDR/S-VDR.

Page 29: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

23 DOC No. 7ZPNA4014

4.3.4.6. Result of diagnosis Confirm that The VDR/S-VDR receives a recording data.

As for the diagnostic result of the [Sensor] section, a result is displayed to the "Diagnosis" lamp at setting.

* Since other sections need to be rebooted after transmitting setup data to the RCU, a

"Diagnosis" result cannot be indicated with a lamp at setting. ● (Green): The VDR/S-VDR receives a recording data ● (Red): The VDR/S-VDR does not receive a recording data. Check a receiving data by real time monitor. ● (Orange): Under a diagnosis * The diagnostic function needs to be operating. A "Diagnosis" lamp becomes a blank display when the diagnostic function is not operating.

A diagnostic function can be started with the [Diagnosis] button on “SYSTEM” screen.

Page 30: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

24 DOC No. 7ZPNA4014

4.3.5. Detail setup window of GPS (sensor section)

Setup screen of GPS is a special screen for connecting two GPS. Sub GPS setting is required when connecting two GPS to one port via a switcher.

4.3.5.1. Identification TAB screen

Set an identification data of connected GPS.

4.3.5.1.1. GPS information

1) Equipment

Enter the name of the connecting equipment. (GPS, DGPS, etc.)

2) Model Enter the model name of the connecting equipment.

3) Manufacturer Enter the name of the manufacturer of the connecting equipment.

4) Serial No. Enter the serial number of the connecting equipment.

* The old equipment by which the serial number is not displayed also exists. In that case, enter "unknown" into the Serial No. column.

4.3.5.1.2. Antenna position

Enter the four values for antenna position. Distance from a Bow/Stern/Port/Starboard to an antenna

Page 31: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

25 DOC No. 7ZPNA4014

4.3.5.2. GPS Selection TAB screen

Set up the “GPS selection” when the “GPS (main+sub)” is selected as a connection equipment.

1) Switch position Select the logic of dry contact signal which is outputted by a GPS switcher. The GPS switcher is connected to “TB406 PI-3” which is a terminal in the RCU. The VDR/S-VDR records the GPS equipment (main or sub) currently recorded as EVENT.

4.3.5.3. GPS Data TAB screen 1) Date and Time

The sentence which acquires “Date and Time” data is a "ZDA" sentence as standard. When the GPS does not output a ZDA sentence, change the sentence to record into "RMC".

2)Datum When the GPS does not output a DTM sentence, clear the DTM setting.

Page 32: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

26 DOC No. 7ZPNA4014

4.4. NSK connection setup

4.4.1. Setting connection

CH33 and CH34 of a Sensor section are the connection CH with NSK. Enable / Disable of heading data connection can be set up to CH33. Enable / Disable of speed data connection can be set up to CH34. 1) Each channel

Enter a check mark into the check box of connected CH. Enable: [ ] (checked) Disable: [ ] (unchecked)

Check box

Select the object CH of set up

Opening detail window

4.4.2. Starting detail setup The detailed connection setting window of each channel is displayed.

1) Selecting CH Click a radio button of setting sensor channel. 2) Click the [Detail] button on sensor section, a detail setting window is displayed.

Page 33: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

27 DOC No. 7ZPNA4014

4.4.3. Detail setup window of Heading data (CH33)

4.4.3.1. Identification TAB screen

Set an identification data of connected equipment which output a Synchro signal or a step signal as heading data. 1) Equipment

Enter the name of the connecting equipment. (Gyro, etc.)

2) Model Enter the model name of the connecting equipment.

3) Manufacturer Enter the name of the manufacturer of the connecting equipment.

4) Serial No. Enter the serial number of the connecting equipment.

* The old equipment by which the serial number is not displayed also exists. In that case, enter "unknown" into the Serial No. column.

Page 34: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

28 DOC No. 7ZPNA4014

4.4.3.2. Heading TAB screen

4.4.3.2.1. Signal Type

Select Synchro or Step as signal type.

4.4.3.2.2. Ratio

Select ratio in 1, 36, 90, 180 or 360 deg.

4.4.3.2.3. Gray Code

Select Order Direction or Reverse Direction as rotation direction.

4.4.3.2.4. Transmitting a setup data (Caution)

When the setup data of "Signal Type", "Ratio", or "Gray Code" are changed, transmit a setup data before inputting an initial value of heading. Click the [Set] button.

* After data transmission, RCU is rebooted automatically and setting data become effective.

Page 35: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

29 DOC No. 7ZPNA4014

4.4.3.2.5. Heading Data

Even if it does not input the initial value of a heading from the OPU, the initial value of a heading can be inputted from on the Heading TAB screen.

1) Measured Value

The current value of a heading is displayed. (The value displayed on this screen is the same as the value displayed on OPU.)

* A heading value is not displayed at stopping the real time monitor. Start the real-time monitor in "Rec data" mode.

2) Initial Value

Click the [Send] button after inputting an initial value. The inputted initial value is registered into the RCU. * An "Initial Value" and "Measured Value" display the same value at opening this screen.

When the correct heading value is displayed, click the [Send] button without inputting an initial value. 3) Checking the heading value

Check that the correct heading value is displayed on the "Measured Value".

Page 36: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

30 DOC No. 7ZPNA4014

4.4.4. Detail setup window of Speed data (CH34)

4.4.4.1. Identification TAB screen

Set an identification data of connected equipment which output a Pulse signal as ship’s speed data. 1) Equipment

Enter the name of the connecting equipment. (Speed log, etc.)

2) Model Enter the model name of the connecting equipment.

3) Manufacturer Enter the name of the manufacturer of the connecting equipment.

4) Serial No. Enter the serial number of the connecting equipment.

* The old equipment by which the serial number is not displayed also exists. In that case, enter "unknown" into the Serial No. column.

4.4.4.2. Ship’s Speed TAB screen

4.4.4.2.1. Pulse

Select pulse rate in 100, 160, 200, or 400 kt/pulse.

Page 37: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

31 DOC No. 7ZPNA4014

4.5. Option unit (NCT-72/63) connection setup In order to record a dry contact signal and an analog signal by the VDR/S-VDR, the Digital Signal Converter (DSC: NCT-72/63) of an option unit is connected to the VDR/S-VDR. Set up the DSC in the following procedure.

4.5.1. Setting connection CH 13, 14, 15, and 16 can connect the NCT-72/63.

Enable / Disable of the DSC connection can be set up to the above-mentioned channels. 1) Each channel

Enter a check mark into the check box of connected CH. Enable: [ ] (checked) Disable: [ ] (unchecked)

Check box

Select the object CH of set up

Opening detail window

4.5.2. Starting detail setup The detailed connection setting window of each channel is displayed.

1) Selecting CH Click a radio button of setting sensor channel. 2) Click the [Detail] button on sensor section, a detail setting window is displayed.

Page 38: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

32 DOC No. 7ZPNA4014

4.5.3. Selecting a recording data

Select the option unit (NCT-72/63) and recording data according to the following procedure. The initial value for receiving the data of the option unit (NCT-72/63) is set up automatically on the detail setting window.

4.5.3.1. In the case of new setting

Select a “Option unit” from the pull-down menu. Click the [Next] button.

Select connected “equipment” from the pull-down menu. • In case of connecting dry contacts Select the “DSC”. • In case of connecting dry contacts and analog signals Select the “DSC+A/D”

(Analog Conversion Board (CEF-60) of an option is built in the DSC.)

Click the [Next] button.

Page 39: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

33 DOC No. 7ZPNA4014

4.5.4. Detail setup window of NCT-72/63

• "Dry Contact" TAB is added as a detailed setting screen of a dry contact. • When a “DSC+A/D” is selected, "A/D" TAB is added as a detailed setting screen of an analog signal.

4.5.4.1. Identification TAB screen

Set an identification data of connected the NCT-72/63. 1) Equipment

"DSC" or "DSC+A/D" is entered automatically. The inside of a parenthesis shows Connection CH.

2) Model Enter the model name of the connecting equipment. (NCT-72/63)

3) Manufacturer Enter the name of the manufacturer of the connecting equipment. (JRC)

4) Serial No. Enter the serial number of the connecting equipment.

Page 40: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

34 DOC No. 7ZPNA4014

4.5.4.2. Data TAB screen

According to selection of "DSC" or "DSC+A/D", an appropriate data is entered automatically.

● DSC+A/D

● DSC

4.5.4.3. Transmitting a setup data for NCT-72/63 connection Transmit a setup data for NCT-72/63 connection to the RCU after entering all data on “Identification” screen Click the [SET] button.

Page 41: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

35 DOC No. 7ZPNA4014

4.5.5. Detail setup window of dry contact (Dry Contact TAB screen) It is a screen for transmitting and receiving the configuration file of NCT-72/63.

4.5.5.1. Program Version Display of NCT-72/63

Click the [Version] button. The program version of NCT-72/63 is displayed.

4.5.5.2. Receiving the configuration file Receive the configuration file of NCT-72/63. 1) Click the [Receive] button. 2) Check that setting data are received in a communication link Monitor display. 3) Completion/failure of reception is displayed in a dialog. Check that completion dialog is displayed.

4.5.5.3. Setup of NCT-72/63

Click the [Setup] button and the screen for the NCT-72/63 setup will appear.

Page 42: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

36 DOC No. 7ZPNA4014

4.5.5.4. Setup screen of sentence data (alarm, door, etc.)

Dry contact data, such as alarm and a door, should be changed into a NMEA sentence data. The screen for creating conversion table file will appear.

In editing not the configuration file that received from NCT-72/63 but the configuration file saved, use “Open” of a

File menu.

4.5.5.4.1. Registration of sentence data converted from dry contact signal

Sentence data are set up to each channel which connected dry contact signal. ● Connection CH

Select a channel which connected dry contact signal.

Page 43: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

37 DOC No. 7ZPNA4014

● State of a dry contact signal

The condition of the equipment shown by OPEN/CLOSE of a dry contact signal is set up.

1) Alarm Select the inputting dry contact state (OPEN/CLOSE) when the connected equipment is a normal state.

2) Door Select the inputting dry contact state (OPEN/CLOSE) when the connected door is open.

● creating sentence data

Select each factor which constitutes sentence data.

1) Dry contact information Select the dry contact information from the pull-down menu of each category according to the connected signal. Although categories are prepared to 3 at the maximum, number of category to be set up is automatically determined by selected data.

Be sure to select a dry contact information from the pull-down menu which can be set up. An unnecessary setup category is in an input prohibition state.

Page 44: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

38 DOC No. 7ZPNA4014

* A selection setup from a tree structure

The tree structure displayed on a left screen is the dry contact signal which can be registered. Sentence data can be set up in double-clicking the data of tree structure.

Selected by Double- Click

2) Identification number of a dry contact A signal of the same kind needs a setup of an identification number. Select the identification number since the pull-down menu will be displayed active. Be careful not to select the same numeric value. The same sentence data will be created

3) Comment A comment can be added to the end of a sentence. Input the character strings which show the contents of a dry contact signal.

Page 45: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

39 DOC No. 7ZPNA4014

3) Registering sentence data Click the [SET] button after all categories are selected and comment is inputted. The sentence according to the contents of selection is created, and it is added to a setup file.

4.5.5.4.2. Deleting and editing a sentence data registered

The sentence registered into the setup file can be deleted. 1) Selecting a sentence

Double-click the sentence displayed on the list. It checks that CH number for deletion is displayed.

2) Deleting a sentence

Click the [Delete] button.

2) Editing a sentence New-set up a sentence data after deletion.

4.5.5.4.3. When All Setup is Completed

When there is no connection of an engine telegraph, move on to the “4.5.5.6” Clause.

Page 46: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

40 DOC No. 7ZPNA4014

4.5.5.5. Registration screen of sentence data for engine telegraph

This screen is an exclusive screen for an engine telegraph setup.

4.5.5.5.1. Screen change

Click an “Engine Telegraph” from “Type” menu.

4.5.5.5.2. Engine telegraph position

Setup an engine telegraph position data according to the following procedure.

1) “Enable” / “Disable” selection Select either “connected” or “disconnected” of the engine telegraph position data by dry contact signals. In connecting, click and enter a check mark into the checkbox.

Page 47: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

41 DOC No. 7ZPNA4014

2) Selecting connected dry contact signals On a selecting menu, all the signals of an engine telegraph position can be registered, the connected dry contact signal is necessary to select. Click and enter a check mark into the checkbox of connection signal.

3) Selecting connection CH

Select the connection CH of NCT-72/63 from the pull-down menu.

4) Selecting state of dry contact signal Select a state of the dry contact signal (Open/Close) at the "Active".

4.5.5.5.3. Sub telegraph position

Set up a sub telegraph position data. Setup procedure is the same as “Engine telegraph position”.

4.5.5.5.4. Operation position

Set up an operation position data of engine telegraph.

1) “Enable” / “Disable” selection Select either “connected” or “disconnected” of the operation position data by dry contact signals. In connecting, click and enter a check mark into the checkbox.

Page 48: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

42 DOC No. 7ZPNA4014

2) Enable setting

Setup procedure is the same as “Engine telegraph position”. 3) Disable setting Select the “Other”.

4.5.5.5.5. Order or Response (Status)

Select the sentence type (Order / Response) of engine telegraph signals.

4.5.5.5.6. Engine, Propeller position

Select the position of an engine and a propeller shaft. • Single or on center line • Port • Starboard

4.5.5.5.7. Registration of Engine telegraph sentence data

The NMEA sentence for engine telegraph is registered. 1) ETL sentence identification number

Select the identification number in the case of registering two or more ETL sentences. When registering only one sentence, it is necessary to select as "01" by a default, but in registering two or more, set up an increment number. It can set up from "01" to "04."

2) Registering sentence data Click the [SET] button. An ETL sentence is registered.

Page 49: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

43 DOC No. 7ZPNA4014

4.5.5.6. All setup is completed

The configuration file created to NCT-72/63 is transmitted when all setup is completed.

1) Transmit the configuration file. Click the [Send] button. 2) The setup screen is completed and it returns to the Transmit/Receive screen of a configuration file. The configuration file is transmitted automatically to the NCT-72/63. 3) Save the configuration file In saving the configuration file of NCT-72/63, it should be saved before transmitting the file. Click the [Save As] button, and save the configuration file.

4.5.5.7. Transmitting the configuration file 1) Check that setting data are transmitted in a communication link Monitor display. 2) Completion/failure of reception is displayed in a dialog. Check that completion dialog is displayed. 3) When transmission is incomplete, click the [Send] button once again.

Page 50: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

44 DOC No. 7ZPNA4014

4.5.5.8. Real time monitor of dry contact sentence

Check that registration and electric wiring of a dry contact signal are correct by the real-time monitor.

4.5.5.8.1. Real Time Monitor

The NMEA sentence can be monitored by the real time monitor on the setting screen. If the dry contact signal monitor of the following clause is used, it can check easily.

4.5.5.8.2. Dry contact monitor

1) Starting Click the [Monitor] button. 2) Operating

Refer to the “7.5” clause.

Page 51: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

45 DOC No. 7ZPNA4014

4.5.5.9. Diagnostic result of dry contact signal

Enter a diagnostic result manually. 1) Dialog for entering a diagnostic result Click the [DSC Check] button. The dialog for entering a diagnostic result will appear. 2) Connection of dry contact signals Check that monitor icons (lamp, door) change according to the change of state of dry connected contact signals. Enter the diagnostic result to radio button (Good/No Good). 3) Sentence setup

Check that the logic of a dry contact signal is correct. • Alarm Normal: Green lamp / Abnormal: Red lamp • Door A door icon means a state of door (Open/Close). Enter the diagnostic result to radio button (Good/No Good). 4) Comment

Enter a comment at NG.

Page 52: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

46 DOC No. 7ZPNA4014

4.5.6. Detail setup window of analog signal (A/D TAB screen)

It is a screen for setup analog signal.

The data which is inputted on the setup screen of each channel are displayed on this screen.

• Connection signal • Current value • Data unit

4.5.6.1. Setting connection of Analog signal Enable / Disable of each Analog signal connection can be set up.

1) Each channel Enter a check mark into the check box of connected CH.

Enable: [ ] (checked) Disable: [ ] (unchecked)

4.5.6.2. Setting detail setup of Analog signal 1) Starting

Click the [channel] button of detail setup channel.

Page 53: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

47 DOC No. 7ZPNA4014

4.5.6.2.1. Identification of Analog signal output Equipment

Set a information data of connected Analog signal output equipment. 1) Equipment

Enter the name of the connecting equipment.

2) Model Enter the model name of the connecting equipment.

3) Manufacturer Enter the name of the manufacturer of the connecting equipment.

4) Serial No. Enter the serial number of the connecting equipment.

* The old equipment by which the serial number is not displayed also exists. In that case, enter "unknown" into the Serial No. column.

4.5.6.2.2. Setup of Analog signal Specifications

Set up a "Volt/Current", a range, etc. by the strap on PCB (ACB: CEF-60). It does not set up with maintenance software.

Page 54: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

48 DOC No. 7ZPNA4014

4.5.6.2.3. Calculating a coefficient

Set up the coefficient of the formula this converts the output value (%) of the ACB into a real value (displayed on a equipment).

1) Selecting CH Select an analog channel to set up.

2) Setting a minimum value Operate the analog signal output equipment so that output a minimum value.

• STEP1: Input the minimum value displayed on the equipment.

• STEP2: Input the A/D conversion value. Click the [Receive] button. A/D conversion value is inputted automatically. * Inputting manually is also possible.

• STEP3: Click the [Set] button.

2) Setting a maximum value Operate the analog signal output equipment so that output a maximum value.

• STEP4: Input the maximum value displayed on the equipment.

• STEP5: Input the A/D conversion value. Click the [Receive] button. A/D conversion value is inputted automatically. * Inputting manually is also possible.

• STEP6: Click the [Set] button.

3) Checking calculated data

Check the conversion formula is correct.

• STEP7: Check that the conversion value on “Check value” and the real value on the equipment are same.

Click the [Check] button. The conversion value is displayed. When the conversion value is not correct, redo from STEP1.

• STEP8: Set the coefficient of the formula. Click the [Apply] button.

Page 55: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

49 DOC No. 7ZPNA4014

4.5.6.2.4. Setting of Analog signal information

The specification and information of the analog signal are set up. 1) Data unit

Select the data unit of receiving data.

2) Contents of connection data Select the contents of connection data. 3) Conversion formula The coefficients of the conversion formula are inputted automatically.

* Inputting manually is also possible.

Conversion formula y=A1*10A2x+B1*10B2 y=Equivalent, x=A/D conversion value, A1, A2, B1, B2=Coefficient

4) Analog signal range Select the analog signal range.

4.5.6.2.5. Setting detail setup of Analog signal

Set the setup data after completing all setup. Click the [Set] button.

4.5.6.3.

No. Unit

00 -

01 deg

02 min-1

03 rpm

04 m/s

05 km/s

06 knots

07 MPa

08 Pa

Page 56: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

50 DOC No. 7ZPNA4014

4.5.6.4. Diagnostic result of analog signal Enter a diagnostic result manually. 1) Dialog for entering a diagnostic result Click the [A/D Check] button. The dialog for entering a diagnostic result will appear. 2) Connection of analog signals

Check that the A/D-conversion value of the connected analog signal is recorded. Enter the diagnostic result to radio button (Good/No Good). 3) Sentence setup

Check that the conversion value is an appropriate value. Enter the diagnostic result to radio button (Good/No Good). 4) Comment

Enter a comment at NG.

Page 57: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

51 DOC No. 7ZPNA4014

4.5.6.5.

4.5.6.6. Analog Signal Converting Board (CEF-60) setup

The parameter setup of the following input signal is set up by the strap on PCB. Other setup items are set up with maintenance software. Refer to the instruction manual of maintenance software for details 1) Setting parameter of each channel

Items Parameter Remark Input channel use YES (enable) / NO (disable) Set “YES” by connecting analog signal or

“NO” by connecting no signal. Input signal Voltage Current Chooses the kind of signal.

±1V ±5V 4-20mA Range

±10V

Choose the range of input signal. A range setup is changed according to the kind of signal.

2) Setting strap on the PCB (CEF-60) CH0 CH1 CH2 CH3 CH4 CH5 CH6 CH7

Page 58: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

52 DOC No. 7ZPNA4014

4.6. Radar connection setup

4.6.1. Setting connection

Enable / Disable of Radar connection and the FGB can be set up. 1) Each channel

Enter a check mark into the check box of “Sub radar” in case of connecting two Radar units. Enable: [ ] (checked) Disable: [ ] (unchecked)

* Since Main Radar is the equipment connected generally, it cannot clear a check mark. 2) Frame Grabber Board (FGB)

• S-VDR (JCY-1850) FGB is an option board in the S-VDR. Therefore, the default setting of FGB is a disable. When the FGB is installed into the RCU, Enter a check mark into the check box of “FGB”

• VDR (JCY-1800) ・ VDR(JCY-1800)

FGB is a standard board in the VDR. Therefore, the default setting of FGB is an enable and it cannot clear a check mark.

4.6.2. Starting detail setup The detailed setup window of Radar is displayed. Click the [Detail] button on Radar section, a detail setup window is displayed.

Page 59: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

53 DOC No. 7ZPNA4014

4.6.3. Detail setup window of Radar

4.6.3.1. Identification TAB screen

4.6.3.1.1. Identification data of Radar

Set an identification data of connected Radar.

1) Model

Enter the model name of the connecting equipment.

2) Manufacturer Enter the name of the manufacturer of the connecting equipment.

3) Serial No. Enter the serial number of the connecting equipment.

* The old equipment by which the serial number is not displayed also exists. In that case, enter "unknown" into the Serial No. column.

Page 60: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

54 DOC No. 7ZPNA4014

4.6.3.1.2. Setup file of FGB

The setup file of FGB can be downloaded and uploaded. The setup file of FGB is saved in the “FGB_Util¥CKA137-JCY1800” folder under an install folder of maintenance

software. A target Radar model or image specification is made into the file name. Select a correct setup file with reference to the following. ● Radar model Cap2-JMA9900-1800.txt

Cap2 "2" shows the object for FGB: CKA -137. Reference: When there is no numeric character (Cap-), the object for CKA-129 is shown.

JMA9900 Radar model 1800 The object for JCY-1800/1850 is shown.

Reference: 1700 shows the object for JCY-1700/S. ● VESA Cap2-1024x768-60Hz-1800.txt

Cap2 "2" shows the object for FGB: CKA -137. Reference: When there is no numeric character (Cap-), the object for CKA-129 is shown.

1024x768 Image Resolution 60Hz Refresh rate 1800 The object for JCY-1800/1850 is shown.

Reference: 1700 shows the object for JCY-1700/S.

4.6.3.1.3. Two Radar images recording mode

Select a recording mode in case of connecting two Radars 1) Recording a image switched The switching record mode is selected in standard system. Select the “Single Record by Switch” from the pull-down menu. 2) Recording both images

The both record mode can be selected in the option system. The option system means a large storage capacity of a capsule and a CF card. Both Radar images can be recorded in the large storage capacity.

Select the “Dual Record” from the pull-down menu.

4.6.3.1.4. In case of using Radar Interface Unit

The Radar Interface Unit should be installed, when the display resolution of connected Radar unit is a UXGA size. 1) Setting a Radar interface unit mode

• When the Radar Interface Unit is installed, select the “NWP-46” from the pull-down menu. • Enter a serial number of NWP-46.

*Caution: The Radar interface unit has a cooling fan. Fan alarm is neglected by the “None” setting.

Page 61: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

55 DOC No. 7ZPNA4014

4.6.3.2. Radar Selection TAB screen

4.6.3.2.1. Select signal

When two radars are connected and VDR/S-VDR record one of two radar images by switching, set the switching signal. 1) Dry contact

Select the “Dry contact”, when recording channel is switched by dry contact signals outputted from a switcher. 2) NMEA

Select the “NMEA”, when recording channel is switched by the PJRC sentence outputted from the JRC radar.

3) None (Auto) Select the “None”, when the switching signal is not connected. Recording channel is switched by detecting a RGB signal. When radar images are received from both channels, the CH1 image is recorded.

4.6.3.2.2. NMEA

Sensor channel which receives a PJRC sentence for switching is set up automatically. Confirm that a Radar connection channel is displayed.

4.6.3.2.3. Dry Contact

Select the logic of the dry contact which is outputted by a switcher. AUTO mode is selected when both of dry contact signals are the same logic.

Logic table of dry contact PI_1 PI_2 MODE OPEN OPEN AUTO OPEN CLOSE CH1 record CLOSE OPEN CH2 record CLOSE CLOSE -

* The switcher is not an optional unit of VDR/S-VDR.

PI_1

PI_2

Page 62: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

56 DOC No. 7ZPNA4014

4.6.3.3. Real Time Monitor

Monitor the Radar Image which is recorded in the VDR/S-VDR at real time to check the operation is working correctly.

1) Selecting the monitor CH

The image received by CH1 is displayed on TAB “Image 1” screen. The image received by CH2 is displayed on TAB “Image 2” screen.

2) Starting monitor START: Click the [Start] button. STOP: Click the [Stop] button.

3) Diagnosis Image quality is judged by a manual. Click the [Image Quality check] button.

Page 63: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

57 DOC No. 7ZPNA4014

● Judge an image quality.

Click the radio button of judgment result. Enter a comment at NG.

* A click of the [Help] button displays advice of an Image quality judging.

* When a location gap of recording image exists or the focus of recording image is incorrect, adjust the value of the configuration file of the FGB by referring to the “11 clause”.

4.6.3.4. Checking setup data Confirm that there is no blank in setting data. 1) Entry lamp

Defect in setting entry (Model, Serial number, etc.) as warning can be displayed to the “Entry” lamp.

● (Green): All entries are inputted. ● (Yellow): The blank entry remains.

Look for a blank entry and input a setup data to blank entry. 2) Image Quality lamp Result of judgment to image quality is displayed to the “Image Quality” lamp.

● (Yellow): An image quality is not judged. Open the "Image quality check" screen and enter a result of judgment.

● (Green): A result of judgment for image quality is good.

● (Red): A result of judgment for image quality is no good.

Page 64: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

58 DOC No. 7ZPNA4014

4.6.3.5. Transmitting setup data Transmit the setup data to the RCU. • Transmit Click the [SET] button. • Cancel Click the [Close] button.

4.6.3.6. Result of diagnosis

As for the diagnostic result of the [Radar] section, a result is displayed to the "Diagnosis" lamp. ● (Green): Result of diagnosis is good. ● (Red): Result of diagnosis is no good. ● (Orange): Under a diagnosis

* Setting modified data of the "Radar" section becomes effective after the reboot of RCU. Therefore, when a setup data is changed, do not refer to the diagnostic result before rebooting the RCU.

* The diagnostic lamp is displayed also on the SYSYTEM screen.

Click the [Reboot] button on a SYSTEM screen after completing setup, and check the diagnostic lamp of a SYSTEM screen.

1) FGB

The Ethernet communication link condition of the Frame Grabber Board (FGB) and the Main Control Board (MCB)

2) Main The RGB signal from the main radar 3) Sub The RGB signal from the sub radar * The diagnostic function needs to be operating. A "Diagnosis" lamp becomes a blank display when the diagnostic function is not operating.

A diagnostic function can be started with the [Diagnosis] button on “SYSTEM” screen.

Page 65: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

59 DOC No. 7ZPNA4014

4.7. Microphone connection setup

4.7.1. Setting connection

Enable / Disable of each Microphone connection can be set up. 1) Each channel

Enter a check mark into the check box of connected CH. Enable: [ ] (checked) Disable: [ ] (unchecked)

Opening detail window

Check box

4.7.2. Starting detail setup The detailed setup window of Microphone is displayed. Click the [Detail] button on Microphone section, a detail setup window is displayed.

Page 66: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

60 DOC No. 7ZPNA4014

4.7.3. Detail setup window of Microphone

4.7.3.1. Identification TAB screen

Set an identification data of connected Microphone.

1) Type Select an indoor type or a waterproof type. 2) Place

Enter the position installed a microphone.

3) Serial No. Enter the serial number of the Microphone unit.

• Serial number: XXXXnnn 4) Model

Enter the model name of the connecting Microphone. [Default setting data] Indoor type: NVT-161 Waterproof type: NVT-162

Page 67: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

61 DOC No. 7ZPNA4014

4.7.3.2. Real Time Monitor

Monitor the Audio of Microphones which is recorded in the VDR/S-VDR at real time to check the operation is working correctly.

Caution: Audio data is mixed by three input signal from each Microphone. For checking that each Microphone is

correctly working, it is necessary to connect only one Microphone to monitor.

1) Selecting the monitor CH Select a monitor channel with a radio button.

2) Starting monitor START: Click the [Play] button. STOP: Click the [Stop] button. 3) Volume

Adjust sound volume by a slide bar. Caution: When sound does not come out from a loudspeaker, check that the speaker output of PC is OFF or sound

volume is a minimum. 4) Diagnosis Audio quality is judged by a manual. Click the [Audio Quality check] button.

Judge an audio quality. Click the radio button of judgment result Enter a comment at NG.

* A click of the [Help] button displays advice of an Audio quality judging.

Page 68: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

62 DOC No. 7ZPNA4014

4.7.3.3. Checking setup data Confirm that there is no blank in setting data. 1) Entry lamp

Defect in setting entry (Model, Serial number, etc.) as warning can be displayed to the “Entry” lamp.

● (Green): All entries are inputted. ● (Yellow): The blank entry remains.

Look for a blank entry and input a setup data to blank entry. 2) Audio Quality lamp Result of judgment to audio quality is displayed to the “Audio Quality” lamp.

● (Yellow): An audio quality is not judged. Open the "Audio quality check" screen and enter a result of judgment.

● (Green): A result of judgment for audio quality is good.

● (Red): A result of judgment for audio quality is no good.

4.7.3.4. Transmitting setup data Transmit the setup data to the RCU. • Transmit Click the [SET] button. • Cancel Click the [Close] button.

Page 69: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

63 DOC No. 7ZPNA4014

4.7.3.5. Result of diagnosis

As for the diagnostic result of the [Microphone] section, a result is displayed to the "Diagnosis" lamp.

● (Green): Result of diagnosis is good. ● (Red): Result of diagnosis is no good. ● (Orange): Under a diagnosis

* Setting modified data of the "Microphone" section becomes effective after the reboot of RCU. Therefore, when a setup data is changed, do not refer to the diagnostic result before rebooting the RCU.

* The diagnostic lamp is displayed also on the SYSYTEM screen.

Click the [Reboot] button on a SYSTEM screen after completing setup, and check the diagnostic lamp of a SYSTEM screen.

1) MIC1-9

The result of Microphone test is displayed. 2) ARB The operating state of data I/F of the Audio Recording Board (ARB) and the Main

Control Board (MCB) * The diagnostic function needs to be operating. A "Diagnosis" lamp becomes a blank display when the diagnostic function is not operating.

A diagnostic function can be started with the [Diagnosis] button on “SYSTEM” screen.

Page 70: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

64 DOC No. 7ZPNA4014

4.8. VHF connection setup

4.8.1. Setting connection

Enable / Disable of each VHF transceiver connection can be set up. 1) Each channel

Enter a check mark into the check box of connected CH. Enable: [ ] (checked) Disable: [ ] (unchecked)

Opening detail window

Check box

4.8.2. Starting detail setup The detailed setup window of VHF transceiver is displayed. Click the [Detail] button on VHF section, a detail setup window is displayed.

4.8.3. Detail setup window of VHF

Page 71: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

65 DOC No. 7ZPNA4014

4.8.3.1. Identification TAB screen Set an identification data of connected VHF transceiver.

1) Model

Enter the model name of the connecting equipment.

2) Manufacturer Enter the name of the manufacturer of the connecting equipment.

3) Serial No. Enter the serial number of the connecting equipment.

* The old equipment by which the serial number is not displayed also exists. In that case, enter "unknown" into the Serial No. column.

4.8.3.2. Real time monitor

Monitor the Audio of VHF transceivers which are recorded in the VDR/S-VDR at real time to check the operation is working correctly.

Caution: Audio data is mixed by three input signal from each VHF transceiver.

1) Starting monitor

START: Click the [Play] button. STOP: Click the [Stop] button. 2) Volume

Adjust sound volume by a slide bar. Caution: When sound does not come out from a loudspeaker, check that the speaker output of PC is OFF or sound

volume is a minimum. 4) Diagnosis Audio quality is judged by a manual. Click the [Audio Quality check] button.

Judge an audio quality. Click the radio button of judgment result Enter a comment at NG.

* A click of the [Help] button displays advice of an Audio quality judging.

Page 72: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

66 DOC No. 7ZPNA4014

4.8.3.3. Checking setup data Confirm that there is no blank in setting data. 1) Entry lamp Defect in setting entry (Model, Serial number, etc.) as warning can be displayed to the

“Entry” lamp. ● (Green): All entries are inputted. ● (Yellow): The blank entry remains.

Look for a blank entry and input a setup data to blank entry. 2) Audio Quality lamp Result of judgment to audio quality is displayed to the “Audio Quality” lamp.

● (Yellow): An audio quality is not judged. Open the "Audio quality check" screen and enter a result of judgment.

● (Green): A result of judgment for audio quality is good.

● (Red): A result of judgment for audio quality is no good.

4.8.3.4. Transmitting setup data Transmit the setup data to the RCU. • Transmit Click the [SET] button. • Cancel Click the [Close] button.

4.8.3.5. Result of diagnosis

As for the diagnostic result of the [VHF] section, a result is displayed to the "Diagnosis" lamp. ● (Green): Result of diagnosis is good. ● (Red): Result of diagnosis is no good. ● (Orange): Under a diagnosis

* Setting modified data of the "VHF" section becomes effective after the reboot of RCU. Therefore, when a setup data is changed, do not refer to the diagnostic result before rebooting the RCU.

* The diagnostic lamp is displayed also on the SYSYTEM screen.

Click the [Reboot] button on a SYSTEM screen after completing setup, and check the diagnostic lamp of a SYSTEM screen.

1) ARB The operating state of data I/F of the Audio Recording Board (ARB) and the Main Control Board (MCB) * The diagnostic function needs to be operating. A "Diagnosis" lamp becomes a blank display when the diagnostic function is not operating.

A diagnostic function can be started with the [Diagnosis] button on “SYSTEM” screen.

Page 73: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

67 DOC No. 7ZPNA4014

4.9. VDR/S-VDR system setup

4.9.1. Starting detail setup

The detailed setup window of VDR/S-VDR is displayed. Click the [Detail] button on VDR section, a detail setup window is displayed.

4.9.2. Detail setup window of VDR VDR/S-VDR

Page 74: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

68 DOC No. 7ZPNA4014

4.9.2.1. Identification TAB screen

4.9.2.1.1. Ship’s Identification

Enter the ship’s identification data. 1) Ship’s name

Enter the ship’s name. 2) IMO ID number.

Enter the IMO ID number.

4.9.2.1.2. Q’ty

These information are used with the Playback software. Enter the value.

4.9.2.1.3. VDR Identification

Enter the VDR/S-VDR identification data. 1) Approval No.

Enter the type approval number of the ship’s class. 2) JRC shipping order

Enter the shipping order number and the serial number of the RCU. 3) Serial No.

Enter the serial number of the installed units which constitutes VDR/S-VDR.

Page 75: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

69 DOC No. 7ZPNA4014

4.9.2.2. Register Information TAB screen

4.9.2.2.1. Register information

Registrant information entered on the Log-in screen is displayed. Registrant information which is stored in the RCU is displayed at receiving the configuration data. Registrant information is updated to the data entered on the "Log in" screen after setting up.

1) Initial The “Initial” means setup in the Mitaka factory. The maintainer name, company name, and the date & time (UTC) are automatically registered.

2) Amendment The “Amendment” means setup on a ship. The maintainer name, company name, and the date & time (UTC) are automatically registered.

Page 76: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

70 DOC No. 7ZPNA4014

4.9.2.3. Maintenance TAB screen

4.9.2.3.1. Battery

The expiry date of the battery is displayed. Enter new expiry date of the battery, when you exchange a battery. The expiry date of a battery is indicated on the battery label. Warning is displayed when exchange is required. (Less than one year)

4.9.2.3.2. FAN

The expiry date of the two cooling FAN in the PSU of RCU is displayed. Enter new expiry date of the cooling FAN, when you exchange two cooling FAN. The life time of cooling FAN is four years. Warning is displayed when exchange is required. (Less than one year)

Page 77: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

71 DOC No. 7ZPNA4014

4.9.2.3.3. Beacon of capsule

Enter an information data of Beacon.

1) Serial No. Enter the serial number of the capsule.

2) Next Replacement

The expiry date of the battery in the beacon of capsule is displayed. Enter new expiry date of the battery in the beacon, when you exchange the beacon unit.

The expiry date of a battery is indicated on the beacon label.

4.9.2.3.4. Blackout test

Check that the VDR/S-VDR is operated in a blackout.

1) Starting blackout test Click the [Test Start] button. Push the [BLACKOUT TEST] switch on the panel of PSU in the RCU for 5 seconds. A result is displayed on a “Test result” lamp.

2) Result of diagnosis A result is displayed to the “Test result” lamp.

● (Green): Result of diagnosis is good. ● (Red): Result of diagnosis is no good. ● (Orange): Under a diagnosis

An operation event of AC Power is displayed in the “Status” window.

Page 78: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

72 DOC No. 7ZPNA4014

4.9.2.4. Software Version TAB screen

4.9.2.4.1. System Version

The software version of JCY-1800/1850 system is displayed.

4.9.2.4.2. Maintenance number

The Maintenance numbers of each unit (PCB) are displayed. Report all Maintenance numbers for repairing.

Page 79: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

73 DOC No. 7ZPNA4014

4.9.2.5. PCB ID TAB screen

4.9.2.5.1. PCB Serial No.

The serial numbers of each PCB are displayed. In replacing a PCB, enter a serial number on a new PCB which is installed into a unit.

• Option unit (DSC: NCT-72/63) When the DSC is connected to the RCU, the PCB serial number of DSC can be inputted * Report a serial number of PCB which is replaced for repairing.

Page 80: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

74 DOC No. 7ZPNA4014

4.9.2.6. Option TAB screen

4.9.2.6.1. NSK

Enter a check mark into the “NSK” check box when a Heading data or ship’s speed data is recorded via NSK in VDR/S-VDR.

1) Setting

• VDR: A NSK-I/F board is an option board. Enter a check mark into the “NSK” check box by installing the NSK-I/F board into the RCU.

• S-VDR: A NSK-I/F board is a standard board. A check mark is entered as default setting.

2) System window

When the “NSK” check box is marked, NSK section is displayed in the System window.

NSK connection channel

Page 81: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

75 DOC No. 7ZPNA4014

4.9.2.7. PI-1 to 3 TAB screen

4.9.2.7.1. Internal Dry Contact

General dry contact signals can be inputted, and general dry contact signal data can be recorded as NMEA sentence data. It is used when the dry contact signal which connects is three or less contacts. The sentence data recorded when a dry contact opens, and the sentence data recorded when a dry contact closes is set up.

Caution: The dry contact signals for "switching Radar" and "switching GPS" are connected to these input ports.

When using this port as switching, it cannot use as a general dry contact signal input port.

4.9.2.7.2. Setup

1) Enable/Disable Enable / Disable of each PI port connection can be set up.

Enter a check mark into the check box of connected port.

2) Header of sentence data Enter the header of output sentence data.

3) OPEN sentence data

The sentence data outputted when a dry contact signal opens is inputted. Enter the sentence data following a header.

4) CLOSE sentence data

The sentence data outputted when a dry contact signal closes is inputted. Enter the sentence data following a header.

4.9.2.7.3. Real time monitor

The sentence data recorded can be monitored. Change the connected dry contact condition (OPEN/CLOSE) and confirm that the contents of the sentence displayed are correctly.

Page 82: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

76 DOC No. 7ZPNA4014

4.9.2.8. Checking setup data Confirm that there is no blank in setting data. 1) Entry lamp Defect in setting entry as warning can be displayed to the “Entry” lamp. ● (Green): All entries are inputted. ● (Yellow): The blank entry remains.

Look for a blank entry and input a setup data to blank entry.

4.9.2.9. Transmitting setup data Transmit the setup data to the RCU. • Transmit Click the [SET] button. • Cancel Click the [Close] button.

4.9.2.10. Result of diagnosis (Blackout test) As for the diagnostic result of the [VDR] section, a result is displayed on a "Diagnosis" lamp.

● (Green): Result of diagnosis is good. ● (Red): Result of diagnosis is no good. ● (Orange): Under a diagnosis

* Setting modified data of the "VDR" section becomes effective after the reboot of RCU. Therefore, when a setup data is changed, do not refer to the diagnostic result before rebooting the RCU.

* The diagnostic lamp is displayed also on the SYSYTEM screen.

Click the [Reboot] button on a SYSTEM screen after completing setup, and check the diagnostic lamp of a SYSTEM screen.

1) ARB The operating state of data I/F of the Audio Recording Board (ARB) and the Main Control Board (MCB) * The diagnostic function needs to be operating. A "Diagnosis" lamp becomes a blank display when the diagnostic function is not operating.

A diagnostic function can be started with the [Diagnosis] button on “SYSTEM” screen.

Page 83: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

77 DOC No. 7ZPNA4014

4.10. Capsule setup

4.10.1. Starting detail setup

The detailed setup window of Capsule is displayed. Click the [Detail] button on Capsule section, a detail setup window is displayed.

4.10.2. Detail setup window of capsule

4.10.2.1. Identification TAB screen Set an identification data of Capsule.

1) Model

Select a model name from the pull down menu. The option model means a large storage capacity (3Gbyte) of a capsule. Two Radar images can be recorded in the large storage capacity.

2) Serial No. Enter the serial number of the connecting equipment.

Page 84: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

78 DOC No. 7ZPNA4014

4.10.2.2. Checking setup data Confirm that there is no blank in setting data. 1) Entry lamp Defect in setting entry as warning can be displayed to the “Entry” lamp. ● (Green): All entries are inputted. ● (Yellow): The blank entry remains.

Look for a blank entry and input a setup data to blank entry.

4.10.2.3. Transmitting setup data Transmit the setup data to the RCU. • Transmit Click the [SET] button. • Cancel Click the [Close] button.

4.10.2.4. Result of diagnosis As for the diagnostic result of the [Capsule] section, a result is displayed on a "Diagnosis" lamp. An state of Ethernet communication link with the RCU and the capsule is diagnosed.

● (Green): Result of diagnosis is good. ● (Red): Result of diagnosis is no good. ● (Orange): Under a diagnosis

* Setting modified data of the "VDR" section becomes effective after the reboot of RCU. Therefore, when a setup data is changed, do not refer to the diagnostic result before rebooting the RCU.

* The diagnostic lamp is displayed also on the SYSYTEM screen.

Click the [Reboot] button on a SYSTEM screen after completing setup, and check the diagnostic lamp of a SYSTEM screen.

1) ARB The operating state of data I/F of the Audio Recording Board (ARB) and the Main Control Board (MCB) * The diagnostic function needs to be operating.

A "Diagnosis" lamp becomes a blank display when the diagnostic function is not operating. A diagnostic function can be started with the [Diagnosis] button on “SYSTEM” screen.

Page 85: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

79 DOC No. 7ZPNA4014

4.11. System Configuration File

4.11.1. File open The VDR/S-VDR can be set up by opening a configuration file. (Not Receiving) Click the “Open” in the “File” menu and select the configuration file to open.

4.11.2. File save The system configuration data in the Maintenance software can be saved to a file. Click the “Save” in the “File” menu and input a file name to save.

Page 86: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

4. Installation, Setup and Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

80 DOC No. 7ZPNA4014

This page is intentionally left blank

Page 87: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

5. SYSTEM ScreenJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

81 DOC No. 7ZPNA4014

5. SYSTEM Screen

On a SYSTEM screen, a connection setup can be entered, and the operating state of a VDR/S-VDR system and the condition (good/no) of a received signal can be checked.

Functions on the SYSTEM screen

● Enable / Disable of each connection channel can be set up. ● Detail setting of each connection channel and VDR/S-VDR operation can be set up. ● The setup information of each connection equipment can be displayed. ● Defect in setting entry as warning can be displayed. ● The receiving state (OK/NG) of each serial channel can be displayed. ● The state (OK/NG) of VDR/S-VDR operation can be displayed. : Radar, Microphone, VHF, Capsule ● The System status information of each section can be displayed. : Radar, Microphone, VHF, Capsule

Page 88: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

5. SYSTEM Screen JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

82 DOC No. 7ZPNA4014

5.1. Common button on the SYSTEM screen How to operate the function of the common button on the SYSTEM screen 1) [Receive] button

The Maintenance software receives the system configuration data of RCU Click the [Receive] button, progress of data reception is displayed on the progress bar arranged at the lower of the screen. The display of system screen will be updated by the received system configuration data.

2) [Diagnosis] button Diagnosis function is controlled by the [Diagnosis] button. Click the [Diagnosis] button, diagnosis function is started and the [Diagnosis] button becomes green. 3) [Set] button

It is used when setting up all system configuration information data. Click the [Set] button, all configuration data is transmitted to the RCU.

* Set up the system configuration data of each section from the each detail setup window. It is unnecessary to use the

[Set] button on the System screen when the detail window is opened by revising setup data. Use the [Set] button when all system configuration data should be set up or only the check box is revised.

4) [Reboot] button

It is used when rebooting the RCU. Click the [Reboot] button, the RCU is operated by renewed system configuration data, after rebooting. Wait until the communication link of Maintenance software and RCU is restarted.

5) [All Default] button

It is used when the system configuration data on the Maintenance software is initialized. Initialized system configuration data is set up as the standard connection of the VDR/S-VDR.

Page 89: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

5. SYSTEM ScreenJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

83 DOC No. 7ZPNA4014

6) [Alarm Mute] button

The [Alarm Mute] button is used to prohibit the ALARM BUZZER of OPU. Click the [Alarm Mute] button. Even if an error occurs during a maintenance communication link, an ALARAM BUZZER does not sound. The color of [Alarm Mute] button becomes green while mute function is effective. Click the green [Alarm Mute] button. Mute function is stopped. Stop the mute function before exiting the Maintenance software.

7) [ACK] button ボタン

A function of [ACK] button on this screen and the function of [ACK] button on the OPU is a same. The [ACK] button is used to stop the ALARM BUZZER. When more than one error is detected, it should be pressed as many times as the number of the errors.

5.2. Sensor section The equipment information and recording data registered by detailed setup of sensor is displayed.

Click the [Unit ID / Record item]/ [Manufacturer / Model] button. Displayed information and displayed button name is changed. * ID number is a error code which is displayed on the OPU. Change of display

Page 90: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

5. SYSTEM Screen JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

84 DOC No. 7ZPNA4014

5.3. Modified setup indicating On a SYSTEM screen, when the setup data is modified, the modified item is indicated by red. Furthermore, the button which should be operated to activate modification is indicated by red.

5.3.1. Connection setup, [SET] button If the check box is changed, the item color is changed from black to red and the [Set] button blinks red.

The red indication means that the item data is not set up to the RCU yet. The indications are returned from red to black after the revised data set up to the RCU. blinks red

5.3.2. [Reboot] button The [Reboot] button blinks red when the RCU is rebooted for operating the modified setup data. Click the [Reboot] button. The indications are returned from red to black after rebooting the RCU.

blinks red

Caution: Even if the [Reboot] button blinks in red, it is not necessary to click immediately.

After all setup is completed, reboot the RCU, and check an operation of the VDR/S-VDR.

Page 91: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

5. SYSTEM ScreenJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

85 DOC No. 7ZPNA4014

5.4. Diagnosis function

5.4.1. Diagnosis button The receive data from a connection equipment and the operating state of the VDR/S-VDR are diagnosed, and the diagnostic result is displayed on a lamp. Click the [Diagnosis] button. While a diagnostic function operates, the color of the [Diagnosis] button becomes green. When the [Diagnosis] button is clicked during a diagnosis, a diagnostic function will stop.

5.4.2. Diagnosis lamp A diagnostic result is displayed as follows.

● (Green): OK ● (Red): NG ● (Orange): Under a diagnosis

Diagnostic items

Section Factor Sensor Serial data

Recording sentence data: receiving / not receiving VDR System operation of VDR/S-VDR

Diagnostic factor: CF Card, lifetime of battery, lifetime of FAN, Initial error and so on. Radar Radar image

Communication link of FGB and MCB: normal / abnormal Recording radar image: receiving the RGB signal / not receiving Quality of Radar image: judgment of a serviceman

Microphone Microphone audio MIC test result: OK / NG Control of ARB by MCB: normal / abnormal Quality of MIC audio: judgment of a serviceman

VHF VHF audio Quality of VHF audio: judgment of a serviceman

Capsule Capsule Communication link of Capsule and RCU: normal / abnormal BER of Capsule: under limit / over limit

5.4.3. Entry lamp Defect in setting entry as warning can be displayed to the “Entry” lamp.

● (Green): All entries are inputted. ● (Yellow): The blank entry remains.

Look for a blank entry and input a setup data to blank entry.

Page 92: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

5. SYSTEM Screen JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

86 DOC No. 7ZPNA4014

5.5. System status window The System status data of each section can be displayed The system status shows the detail information of an error factor.

* Effective section: VDR, Radar, Microphone, VHF, Capsule * Sensor section shows a recording sentence ID list.

1) Selection

Click a section name (e.g. Radar) positioned upper left. 2) System status window System status window of selected section is opened.

Detail information of an error factor is shown in the window. To close the window, click the [X] button. Click the VDR section name

Page 93: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

5. SYSTEM ScreenJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

87 DOC No. 7ZPNA4014

3) Sensor section Click the [Sensor] button positioned upper left of the sensor section. The recording sentence ID list will appear.

Page 94: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

5. SYSTEM Screen JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

88 DOC No. 7ZPNA4014

5.6. Operation button Click a operation button arranged on the left of the SYSTEM screen. A operation window or application which selected is activated.

Button Operation See

Log in Return the Log in screen 2.1.

Home Return the HOME screen for selecting work item 3.1

System The connection, setup, operation of VDR/S-VDR are expressed as the configuration screen of the VDR/S-VDR system.

4.1

Event VDR/S-VDR operation is expressed as event list. It is useful for researching a cause of error.

6

Playback Recorded data of a Capsule and CF card is checked with the Playback software. 10

Report The report folder is created on the Desktop after completing installation. Report files are saved into this folder automatically.

13

Logout The Maintenance software disconnects the RCU communication. The Maintenance software is exited.

2.2

5.7. File menu System configuration data in the Maintenance software is saved/opened by the file menu.

Page 95: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

6. EVENT MonitorJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

89 DOC No. 7ZPNA4014

6. EVENT Monitor Monitor the operation event of VDR/S-VDR to check that VDR/S-VDR system is working correctly. The EVENT monitor can display a receiving EVENT data from the VDR/S-VDR. Furthermore, the EVENT monitor can display EVENT Log files in the VDR/S-VDR additionally.

6.1. Starting 1) Click the [EVENT] button on the SYSTEM screen. 2) Select the display language of event data

Select English or Japanese with a radio button, and click the [OK] button. 3) Start the Event monitor The EVENT monitor is started automatically. If EVENT data are received, it will display on real time. 4) RCU reboots

When the RCU is rebooted by the [Reboot] button on the "SYSTEM" screen during operating the Event monitor, the Event monitor can display the first event data after starting of the RCU. Reboot the RCU for checking event data from starting of the RCU.

Page 96: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

6. EVENT Monitor JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

90 DOC No. 7ZPNA4014

Page 97: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

6. EVENT MonitorJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

91 DOC No. 7ZPNA4014

6.2. Modification of EVENT list display

Old event data can be displayed by downloading event log files from the RCU. The event log files consist of event data recorded on the CF card by the RCU.

6.2.1. EVENT log files

1) Click the [Get Event Log].

2) Progress of receiving is displayed by Progress bar. 3) Old event data is added to the event list display.

6.2.2. Event list after last boot display The event data list can be displayed after last boot of the RCU. Use this function, when there is no necessity of checking older EVENT before last boot.

1) Click the [Last boot] button. 2) The older event data before last boot is cleared The [Last boot] button becomes blue color. 3) Click the [Last boot] colored blue. 4) Cleared old event data is displayed. (return to the all event data display) The [Last boot] button becomes gray color again.

Page 98: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

6. EVENT Monitor JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

92 DOC No. 7ZPNA4014

6.2.3. Extract event data

EVENT to display can be extracted per category. • The extracted event data list is displayed in a new Window. • Kind of category: NMEA, FGB (Radar image), Audio, Capsule, Card, System • It is only any one category that it can extract. 1) Select a category to extract.

Click the button of a target category name 2) The extracted event data list is displayed on a new opened Window. All category name buttons become an invalid display. 3) In changing the EVENT category to display, close the present display Window of Extract EVENT.

All category name buttons return to an effective display.

Page 99: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

6. EVENT MonitorJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

93 DOC No. 7ZPNA4014

6.2.4. EVENT sort

The EVENT monitor supports a sort function. 1) Click the each field title. It is displayed the sorted event list. 2) EVENT which received during the sort display is added to a head of list.

6.2.5. EVENT clear The all event data on the list can be cleared. 1) Click the [Clear] button.

6.2.6. Display language change Display language of event data list can be changed. 1) Click the English or the Japanese from the “View” menu.

Page 100: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

6. EVENT Monitor JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

94 DOC No. 7ZPNA4014

6.3. EVENT log file open

The EVENT log file recorded by the RCU and the file saved by the EVENT monitor can be opened. • The saved event log files in the CF card • The downloaded event log files from the capsule • The saved event log files by the Event monitor

1) Open a file Click the “Open” from the “File” menu. The File dialog is opened. 2) Select a file Select a “writefile.txt” on a saved folder of Event log. 3) Display event log Event log data is displayed on the event list.

6.4. EVENT log file save

The Event monitor can save all event data currently displayed as a file. • “evt” file type: It is opened by the Event monitor.

• “csv” file type: It is opened by the Excel or other editor.

1) Save a file Select the “Save” or the “CSV Save” from the “File” menu.

• Save: “evt” file type •CSV Save: “csv” file type

2) Select a save folder Select a save folder on the File dialog.

Page 101: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

6. EVENT MonitorJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

95 DOC No. 7ZPNA4014

6.5. EVENT monitor record The receiving EVENT data can be recorded as a file. 1) Record start Click the [Record Start] button. Select a save folder on the File dialog. A file name means recording start time This button display changes to [Record Stop]. 2)Recording file The recording file is saved on the desktop. 3)Record stop Click the [Record Stop] button. This button display changes to [Record Start].

Page 102: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

6. EVENT Monitor JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

96 DOC No. 7ZPNA4014

This page is intentionally left blank

Page 103: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

7. Real time Monitor (Menu)JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

97 DOC No. 7ZPNA4014

7. Real time Monitor (Menu)

Although NMEA data, image data and audio data can be monitored on each "Detail screen" of a SYSTEM screen, real time monitor to which the facility was extended can be started from the menu.

● Comparison table of Detail window and Menu

Monitor data Menu Detail window NMEA The monitor of all or some channels is

supported. The monitor channel is changed easily.

The only channel of opened detail window is monitored.

Radar image The window size can be extended. The radar image is displayed on the wide window.

The window is fixed. The radar image is displayed on the small window.

Audio same Dry contact signal same

● Starting Each real time monitor can be started from the menu directly.

Use these real time monitors for checking reception data without setup.

7.1. Starting

1) Menu Click the “Monitor” menu and open the pull down menu. 2) Pull down menu Click the data item for real-time-monitoring.

Page 104: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

7. Real time Monitor (Menu) JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

98 DOC No. 7ZPNA4014

7.2. NMEA monitor

Monitor the NMEA sentence data, and check the sentence specified by the installation drawings is collected correctly.

7.2.1. Monitor conditions setup Set up the monitor conditions.

When the PC of low specification is used, monitor every 1 CH. If the monitoring of two or more CH(s) is carried out simultaneously, the rate of a CPU load becomes 100%, and operation becomes impossible. When operation is impossible, the task manager of Windows is started by <Alt>+<Ctrl>+ <Delete>.

Terminate the maintenance software.

7.2.1.1. Selecting the monitor channel Select the CH to monitor. Click the CH to monitor from the pull down menu.

Page 105: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

7. Real time Monitor (Menu)JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

99 DOC No. 7ZPNA4014

7.2.1.2. Selecting the monitor data type Click the radio button of data type (“RCV data”/”REC data”) to monitor.

● “RCV data”: Monitors all receiving data from selected channel. The sentence data which is not recorded by the VDR/S-VDR is also displayed.

● “REC data”: Monitors the sentence data which is recorded by the VDR/S-VDR.

The sentence which is not recorded is not displayed even if it has received. The monitor data is displayed by the sentence format currently recorded in the VDR/S-VDR.

“RCV data” monitor It is used when the DAU begins receiving NG. When wiring is reverse-connected, the data which carried out character transformation is displayed.

7.2.2. Monitor start and stop 1) Monitor start Click the [START] button.

The monitoring channel indicator becomes Green.

2) Monitor stop Click the [STOP] button.

The monitoring channel indicator returns Gray.

● “REC data” The addition and deletion of the CH to the monitor can be operated freely.

● “RCV data”

Only independent CH can be monitored.

7.2.3. Monitor pause 1) Pause

Click the [Pause] button.

2) Restart The [Pause] button is changed to the [PLAY] button during the pausing. Click the [PLAY] button.

Page 106: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

7. Real time Monitor (Menu) JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

100 DOC No. 7ZPNA4014

7.2.4. Event clear The monitoring window can be cleared. Click the [Clear] button.

7.2.5. File save Monitor data can be saved in the file.

1) Select a saving folder

Click the [Browse] button to select the saving folder. The saving file name is being fixed to RtMonitor1.txt.

2) Save start

Click the [SAVE START] button. The sentence data which is monitored can be saved in the text file.

3) Save stop

The [SAVE START] button is changed to the [SAVE STOP] button during the saving. Click the [SAVE STOP] button.

7.2.6. Quit 1) Monitor stop

Stop all of the channel which is monitoring. 2) Quit

Click the [Close] button.

When the maintenance software is quitted, please make sure that a real –time monitor has stopped Reboot RCU, when the maintenance software has been quitted without stopping a real-time monitor. The output of real-time data stops.

Page 107: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

7. Real time Monitor (Menu)JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

101 DOC No. 7ZPNA4014

7.3. Audio monitor Monitor the Audio data which is recorded in the ARB to check the operation is working correctly.

Play button Stop button Volume

7.3.1. Selecting the monitor channel Click the selection button of CH to monitor.

▪ Audio1: MIC1-- MIC3 ▪ Audio2: MIC4-- MIC6 ▪ Audio3: MIC7-- MIC9 ▪ VHF: VHF1-- VHF3

Select the CH to monitor. More than two CH cannot be played at the same time. For each connecting unit (MIC1,2,3,4,5,6,7,8,9, VHF1,2,3), connect only one unit to check the operation.

→ Each monitor CH is mixed by 3 input signals. For checking that each unit is correctly working, it is necessary to connect only one unit to monitor.

7.3.2. Monitor start and stop 1) Monitor start

Click the [Play] button. The Audio of selected CH is outputted from speaker. * Keep in mind that a sound is not outputted unless the PC speaker is "effective."

2) Monitor stop

Click the [Stop] button to stop monitoring.

The monitored sound is played about four second later than sound source.

7.3.3. Changing the monitor channel Follow the following procedure, when changing the monitor CH. Stop → Change monitor CH → Start

7.3.4. Quit Click the [X] button on the upper right of the window after stop monitor.

Page 108: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

7. Real time Monitor (Menu) JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

102 DOC No. 7ZPNA4014

7.4. Radar monitor Monitor the Radar Image Monitor which is recorded in the FGB to check the operation is working correctly.

7.4.1. Operation It is not necessary to operate it since the monitor is started automatically. The image which the VDR/S-VDR is recording is displayed. The image is updated in an interval of 15 seconds as well as a record interval.

The monitored image is displayed later than the record time several seconds

Page 109: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

7. Real time Monitor (Menu)JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

103 DOC No. 7ZPNA4014

7.5. Dry Contact monitor Monitor the dry contact data which is collected in the NCT-72/63, and check a dry contact state specified by installation drawings is collected correctly. Be sure to check the collecting data of all channels. This monitor analyzes the contents of NMEA sentence data outputted from the NCT-72/63, and a dry contact state is indicating by an icon.

7.5.1. Monitor start It is not necessary to operate it since the monitor is started automatically.

The monitoring channel indicator becomes Green.

7.5.2. Monitor display In order to check the dry contact state by a monitor window, it is necessary to change the dry contact state. The NMEA sentence is outputted from the NCT-72/63 at changing state of a dry contact.

Sentence output timing of the NCT-72/63 ▪ At changing state of a dry contact ▪ All sentences are outputted for 5 minutes interval and at electric power supply ON.

Page 110: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

7. Real time Monitor (Menu) JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

104 DOC No. 7ZPNA4014

7.5.2.1. Dry contact of Alarm A dry contact state is displayed with a lamp icon.

▪ Green lamp: A target status is normal. ▪ Red lamp: A target status is abnormal.

7.5.2.2. Dry contact of Door A dry contact state is displayed with a door icon. ▪ : A door is open. ▪ : A door is closing.

7.5.2.3. Engine Telegraph The channel which connected the engine telegraph is displayed with yellow lamps. Click any yellow lamps, and it will change to the window for an engine telegraph.

The present position is displayed by a green lamp on "Engine telegraph position", "Sub-telegraph position", and "Operating location" .

When the [Back] button is clicked, an engine telegraph window will be closed and it will return to a dry contact state window.

Page 111: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

7. Real time Monitor (Menu)JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

105 DOC No. 7ZPNA4014

7.5.3. Clear the result of monitor The result of monitor can be cleared. Click the [Clear] button.

7.5.4. The wrong result of monitor When the monitoring dry contact state shows contrary information to the outputting information of the connected equipment, correct the setting data of the NCT-72/63. Since the dry contact state (OPEN/CLOSE) which shows a normal state is set up conversely.

Page 112: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

7. Real time Monitor (Menu) JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

106 DOC No. 7ZPNA4014

This page is intentionally left blank

Page 113: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

8. System Status DisplayJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

107 DOC No. 7ZPNA4014

8. System Status Display

The operating state of VDR/S-VDR is displayed in detail. Check a detailed factor of error by this screen. Although the system state is displayed in each category unit in the SYSTEM screen, all items can be displayed on this system status screen.

8.1. Starting Click the “System Status” from the “System” pull down menu.

8.2. System status display Window All lamps are displayed green during the VDR/S-VDR operating normally.

8.2.1. System Control

Page 114: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

8. System Status Display JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

108 DOC No. 7ZPNA4014

8.2.2. Record Control

8.2.3. ROM Checksum

Page 115: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

8. System Status DisplayJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

109 DOC No. 7ZPNA4014

8.3. Start System status display

8.3.1. When the diagnostic function is started Since the diagnostic result is displayed, it is not necessary to operate it. The [Diagnosis] button is a green display.

8.3.2. When the diagnostic function is stopped When the diagnostic function has stopped, it is necessary to start a diagnostic function. Click the [Diagnosis] button. The [Diagnosis] button becomes a green display and a diagnostic result is displayed.

8.3.3. Stop the diagnostic function Click the [Diagnosis] button during the diagnostic function operating.

The diagnostic function is stopped.

8.4. Diagnosis lamp of orange in normal operation Even if the VDR/S-VDR is operating normally, some diagnosis lamps do not become a green.

1) Capsule

The “Capsule” section of the “Record Control” window ● “Write” lamp of “Config” partition It becomes a green lamp display only immediately after transmitting configuration data.

If the RCU is rebooted, it will return to the orange display under diagnosis.

2) Microphone test The “Audio” section of the “Record Control” window ● “Running test” lamps of “Microphone test”

A diagnostic lamp serves as an orange display under diagnosis until 12 hours pass and it carries out a microphone test, after starting. It is not necessary to check becoming a green lamp display at installation work.

Page 116: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

8. System Status Display JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

110 DOC No. 7ZPNA4014

8.5. System status data file If the system configuration file (McbDataInfo.dat) saved at the report folder created after the completion of installation

is opened, the system state file (Status.dat) saved at the same folder can be opened automatically, and the diagnostic result at that time can be displayed.

So the diagnostic result at that time can be reproduced under offline without connecting the VDR/S-VDR.

Refer to the 13th clause about the report folder.

8.5.1. Connection with the VDR/S-VDR The system status file can not be opened during the communication link with the VDR/S-VDR, because the Maintenance software receives a new system state data from the VDR/S-VDR. Disconnect a LAN cable.

8.5.2. File Open the system configuration file (McbDataInfo.dat). Click the “Open” from the “File” pull down menu.

8.5.3. System status data display Start the System status display function. Click the [Diagnosis] button. The system state data in selected file will be displayed.

Page 117: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

9. Functions of MenuJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

111 DOC No. 7ZPNA4014

9. Functions of Menu

The serviceable function which can be operated from the menu is explained.

9.1. Menu table

Refer to a remark column. Mark (►) shows a function which is explained in this clause.

Menu Pull down menu Function Reference Open File open : System configuration file of the VDR/S-VDR or the RMS

System status file of the VDR/S-VDR or RMS Moreover, if the system configuration file (McbDataInfo.dat) saved at a report folder created after the completion of installation is opened, a system state file (Status.dat) saved at the same folder can be opened automatically, and the diagnostic result at that time can be reproduced. Refer to the 13th clause about the report folder.

- File

Save File save : System configuration file of VDR/S-VDR or the RMS - Control Control the VDR/S-VDR by the Maintenance software ►

MCB Setup Edit system configuration data of the MCB Do not use this function without instruction of the Mitaka plant.

RMB Setup Edit system configuration data of the RMB Do not use this function without instruction of the Mitaka plant.

System Status Show the system status the 8 clause FGB setup Show the WEB of the FGB

Do not use this function without instruction of the Mitaka plant. -

FGB Utility Adjust the FGB the 11 clause FGB Update Update the program of FGB The 14.2 clause

System

HVR Show the web of the capsule Do not use this function without instruction of the Mitaka plant.

Event Event Monitor Real time monitor of EVENT the 6 clause

NMEA Real time monitor of NMEA sentence the 7.1 clause Audio Real time monitor of audio the 7.2 clause Radar Real time monitor of image the 7.3 clause

Monitor

Dry Contact Real time monitor of dry contact the 7.4 clause Convert Exchange the recorded sensor data to text file ► Data Config Extract a setup file from Config file saved in the CF card and the

capsule ►

Error Code List (English) Error Code List (Japanese)

Show an explanation of Error code displayed on the OPU ►

Help

Software Version Show the software version of Maintenance software ►

Page 118: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

9. Functions of Menu JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

112 DOC No. 7ZPNA4014

9.2. Control The VDR/S-VDR can be controlled by the Maintenance software.

9.2.1. Starting Click the “Control” of menu.

9.2.2. Reboot system The MCB (VDR/S-VDR) and RMB (RMS) can be rebooted with remote control.

1) Click the target unit button. ([MCB] button, [RMB] button) * This [MCB] button and the [Reboot] button is the same function.

Page 119: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

9. Functions of MenuJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

113 DOC No. 7ZPNA4014

9.2.3. FGB maintenance mode

The MCB controls the FGB to record a image file during a VDR/S-VDR operating. The FGB can not take maintenance while the MCB is communicating to the FGB with Ethernet link. FGB maintenance mode means that the MCB disconnects the Ethernet link with the FGB.

* FGB-related functions make FGB maintenance mode start automatically. It is not necessary to use this function.

1) Start Click the [START] button. 2) Stop Click the [Stop] button. * Caution: Radar image can not be recorded during the FGB maintenance mode.

Be sure to stop this mode.

9.2.4. Initial Error Release The Initial error (Error code: 01__) is released. 1) Click the [MCB] button.

9.2.5. Real Time Clock Setup The date and time to the real time clock IC of the MCB or RMB can be confirmed and set up.

9.2.5.1. Display the date and time

1) Click the target unit button. ([MCB] button, [RMB] button) The date and time of unit selected is displayed.

9.2.5.2. Set up the date and time

1) Click the target unit button. ([MCB] button, [RMB] button) The date and time of unit selected is displayed.

2) Enter the date and time. 3) Click the [Set] button. 4) Click the [Reboot] button of the target unit. (Refer to the 9.2.1 clause) 5) When the unit is rebooted, the entered date and time is registered. Confirm the date and time after rebooting.

Page 120: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

9. Functions of Menu JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

114 DOC No. 7ZPNA4014

9.2.6. Request Unit Mode and Function

The operation mode and function status of the MCB or the RMB can be displayed.

1) Click the target unit button. ([MCB] button, [RMB] button)

MODE: • Application • Safe FUNCTION: • Normal • Download

Usually, “MODE=Application FUNCTION=Normal” is displayed. It can be returned to the Normal mode when the update of the program has failed and does not operate as "FUNCTION=Download".

Click the [Cancel] button.

Ask the Mitaka factory in other case because the VDR/S-VDR is not operating normally.

Page 121: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

9. Functions of MenuJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

115 DOC No. 7ZPNA4014

9.3. Convert (Recorded sensor data to text file)

The recorded NMEA sentence data can be converted to a text file. The NMEA sentence data is files saved in the CF card or downloaded from the capsule.

9.3.1. Starting 1) Click the "Convert" from the "Data" pull down menu on the system screen.

9.3.2. Converting to a text file

1) Select a “Log” folder Click the [Browse] button, and select a “Log” folder which is root folder of saved log files in the recorded data.

2) Select a folder to save a text file

Click the [Browse] button, and select a folder to save a text file.

3) Start converting Click the [Convert] button and then conversion is started. Progress of converting is displayed by Progress bar.

4) Name of a text file

The name of a converted text file is a "recording start time". It is saved on a selected folder. Sample: 200401201030.txt (10:30 on January 20, 2004)

Page 122: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

9. Functions of Menu JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

116 DOC No. 7ZPNA4014

9.4. Config (Extract a setup file from a SysInfo.dat file)

A setup file of each unit (MCB, FGB, etc.) is extracted from a “SysInfo.dat” file saved in the CF card or the capsule.

9.4.1. Starting 1) Click the "Config" from the "Data" pull down menu on the system screen.

9.4.2. Select a Config file 1) Select a file

Click the [Open file] button, and select a “SysInfo.dat” file saved in a “Init” folder of recorded data.

9.4.3. Save a setup file of each unit Select a target unit to save a setup file. 1) Select a target unit

Click the button of a target unit name 2) Save a file Select a save folder, and input a file name.

Page 123: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

9. Functions of MenuJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

117 DOC No. 7ZPNA4014

9.5. Error Code List

The cause and its countermeasure of the error code displayed on the OPU can be displayed.

9.5.1. Starting 1) Click the "Error Code List" from the "Help" pull down menu on the system screen.

9.5.2. Error code list The error code list is displayed. 1) Click the “Book” icon of “SYSTEM Code No.” on the “Contents” TAB screen. 2) Click the “Book” icon of each error number. The cause and its countermeasure of the error code are displayed.

Page 124: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

9. Functions of Menu JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

118 DOC No. 7ZPNA4014

9.6. Software Version display

The software version display Window is opened.

9.6.1. Starting 1) Click the “Software Version” from “Help” menu.

9.6.2. Software version display window

Page 125: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

10. PlaybackJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

119 DOC No. 7ZPNA4014

10. Playback

Check that Installation, Setup, and Functions of the VDR/S-VDR are completed appropriately by playback data of the capsule and the CF card.

10.1. Starting

10.1.1. Start on the SYSTEM screen Click the [Playback] button on the SYSTEM screen.

10.1.2. Start on the HOME screen When the “HOME” screen is displayed, start the Playback software with the [Playback] button of “Work” section.

1) Click the [Playback] button.

Page 126: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

10. Playback JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

120 DOC No. 7ZPNA4014

10.2. Playback Software

The Launcher of Playback software starts. The recorded data of VDR/S-VDR are saved on the Capsule and the CF card. It is necessary to play back and check these both. 1) Capsule The recorded data is downloaded from the Capsule to a maintenance PC via LAN. 2) CF card The recorded data is copied from the CF card to a maintenance PC with card adaptor.

Check the recorded data of both a capsule and CF card at the end of installation.

Operating procedures is different with a capsule and CF card. Play back the recorded data with reference to the procedure after the following page, and check the data.

Refer to the instruction manual of Playback software for details

10.3. Check recorded data The recorded data is checked as follows:

• Check that all NMEA sentences are recorded. • Check that radar images are recorded. • Check that selected radar images are recorded in two radar connection system. • Check that conversation in a bridge and wings is recorded • Check that communication of a VHF transceiver is recorded

Page 127: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

11. Frame Grabber Board (CKA-137) setup - FGB utility -JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

121 DOC No. 7ZPNA4014

11. Frame Grabber Board (CKA-137) setup - FGB utility -

“FGB_Utility” software is useful for setup and tuning the Frame Grabber Board CKA-129/CKA-137. The setup menu contain that the capture setup file and other file set the board. The tuning menu contains that sync polarity tuning, horizontal/vertical position tuning, and sampling phase tuning.

11.1. Check the Radar image specifications For proper capture setting, check the Radar image specifications (VESA format only). Check the item as bellow.

Resolution: (ex. 1280x1024) Vertical synchronous signal frequency (Refresh rate): (ex. 60 Hz) Horizontal synchronous signal frequency: (ex. 75 kHz) Vertical synchronous signal polarity: (ex. Positive or Negative) Horizontal synchronous signal polarity: (ex. Positive or Negative)

11.2. Setup & Capture

11.2.1. Start the "FGB Utility" program Click the “FGB Utility” from System menu of the VDR/S-VDR Maintenance Software.

Page 128: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

11. Frame Grabber Board (CKA-137) setup - FGB utility - JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

122 DOC No. 7ZPNA4014

11.2.2. Select the channel for tuning

a) Click the icon.

If tuning the channel 2, click the icon. And if “Ch2.txt NG” message appears, set the channel 2

capture setting using [Ch 2 capture setting] menu, refer to next section. The following message appears. This message appears at first connected to the board.

b) Click the [OK] button.

c) "Changed to channel 1" message appears on left below status bar.

11.2.3. Check the board measured Radar image format Check the board measured Radar image format as bellow. a) Click [Information (I)] -> [ADC status] menu. The following message appears.

b) Click the [No] button. "ADCtxt_Analysis Function" window appears.

Page 129: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

11. Frame Grabber Board (CKA-137) setup - FGB utility -JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

123 DOC No. 7ZPNA4014

c) Check the board measured Radar image format same as that the Rader specifications.

Resolution (estimated value): Vertical synchronous signal frequency (Refresh rate): Horizontal synchronous signal frequency: Vertical synchronous signal polarity: Horizontal synchronous signal polarity:

If the “Sync Activity” column is inactive, synchronous signal can not be detected on board. So, check the cable connecting, signal output or input channel.

Measured value Sync Activity ch 1 Sync Activity ch 2 V sync polarity H sync polarity V sync frequency H sync frequency: Total line number Setup value V sync polarity H sync polarity Resolution (estimated value)

Page 130: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

11. Frame Grabber Board (CKA-137) setup - FGB utility - JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

124 DOC No. 7ZPNA4014

11.2.4. Set the capture setup

a) Click the [Setup(S)] -> [Ch 1 capture setting] menu.

(If set the channel 2 capture setup, click the [Ch 2 capture setting] menu.) File select window appears.

b) Click the "CKA137-JCY1800" folder. (If CKA-137 board installed in JCY-1700, click the "CKA137-JCY1700" folder.)

c) Click the capture setting file. File name is formatted as bellow. JRC Radar setting: Cap2-"Radar model name"-1800.txt

| | | CKA-137 board installed in JCY-1800/1850

ex. JMA9900 VESA format setting: Cap2-"Resolution"-"V sync frequency"-1800.txt Resolution: 800x600, 1024x768, 1152x864, 1280x960, 1280x1024, 1600x1200 pixels V sync frequency: 60, 70, 72, 75, 85 Hz (1600x1200 resolution is 60 Hz only.)

Page 131: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

11. Frame Grabber Board (CKA-137) setup - FGB utility -JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

125 DOC No. 7ZPNA4014

d) Click the [Open] button on file select window. The following message appears. If "Capture1.txt write NG" message appears, retry to step a) to d).

e) Click the [OK] button on message box.

11.2.5. Capture the Radar image Capture the Radar image as bellow.

a) Click the icon on the top of menu.

"Finished the capture image." massage is displayed on left below status bar.

b) Click the icon.

Captured PNG image is displayed.

Page 132: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

11. Frame Grabber Board (CKA-137) setup - FGB utility - JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

DOC N

11.3. Tuning

Tune in the following order.

1) Sync polarity tuning 2) Horizontal position tuning 3) Vertical position tuning 4) Sampling Phase tuning

11.3.1. Sync polarity tuning a) Click [Information (I)] -> [ADC status] menu.

"ADC.txt response" window appears. b) Click the [No] button.

"ADCtxt_Analysis Function" window appears. c) Check the H sync polarity.

If measured H sync polarity same as that the setup, step to next section. If not same as that setup, step to d).

126 o. 7ZPNA4014

Measured value Setup value

Page 133: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

11. Frame Grabber Board (CKA-137) setup - FGB utility -JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

127 DOC No. 7ZPNA4014

d) Click the [Tuning (T)] -> [H Sync polarity reverse]

The following message appears.

e) Click the [OK] button.

Automatically reverse the H sync polarity, and capture the image. And the following message appears.

f) Click the [OK] button. g) Reread the [ADC status] menu, and check that measured H sync polarity same as that the setup.

V sync polarity, it does the same procedure using [V Sync polarity reverse] menu.

Page 134: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

11. Frame Grabber Board (CKA-137) setup - FGB utility - JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

128 DOC No. 7ZPNA4014

11.3.2. Horizontal position tuning

If the captured image shifted horizontal, tune the Horizontal position. If the captured image large shifted, tune by the mouse. If the small shifted, tune by the manual.

11.3.2.1. By the mouse

a) Click the [Tuning (T)] -> [Horizontal POSI. Mouse] menu. The following message appears.

b) Click the [OK] button on message box.

Automatically capture the image, and the following message appears.

c) Click the [OK] button on message box.

Message box disappear. d) Click the horizontal edge of the image. Don’t care the Y coordinates.

The following message appears.

Click the horizontal edge of the image.

Page 135: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

11. Frame Grabber Board (CKA-137) setup - FGB utility -JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

129 DOC No. 7ZPNA4014

e) If execute horizontal position tuning at this point, click the [Yes] button. If retry to point the image, click the [No]

button and click the horizontal edge of the image.

Shifted the horizontal setup, and captured the image. The result message appears.

f) Click the [OK] button on message box.

11.3.2.2. By the manual

a) Click the [Tuning (T)] -> [Horizontal POSI. manual] menu. The following message appears.

b) Click the [OK] button on message box. Automatically captured the image and the following message appear.

c) If the image will be moved left, click the [Yes] button. If the image will be moved right, click the [No] button. If will be end the tuning, click the [Cancel] button.

Shifted the horizontal setup, and captured the image. And the message appears. d) Repeat the step c) to the right position.

11.3.3. Vertical position tuning If the captured image shifted vertical, tune the Vertical position. If the captured image large shifted, tune by the mouse. If the small shifted, tune by the manual. The vertical position tuning procedure is same as that the Horizontal position tuning. Use the [Vertical POSI. Mouse] or [Vertical POSI. Manual] menu, and refer to Horizontal position tuning procedure.

Page 136: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

11. Frame Grabber Board (CKA-137) setup - FGB utility - JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

130 DOC No. 7ZPNA4014

11.3.3.1. Sampling Phase tuning

If the captured image out of focus, tune the sampling phase. Normally, do the Phase AUTO turning. Phase AUTO tuning execute on still image, so stop the Radar transmit.

a) Click the [Tuning (T)] -> [Phase AUTO] menu.

The following message appears.

b) Click the [OK] button on message box.

Phase AUTO tuning start, and 35 images captured for tuning. During the tuning, tuning process display on the left bellow status bar. End the tuning, the result message appears.

c) click the [No (N)] button on message box.

Page 137: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

12. Option System setupJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

131 DOC No. 7ZPNA4014

12. Option System setup The data output conditions for the real-time monitor system are set up.

12.1. Starting

12.1.1. Start on the SYSTEM screen When the “SYSTEM” screen is displayed, move to the “HOME” screen.

Click the [HOME] button to move to the “HOME” screen.

12.1.2. Start on the HOME screen “Option PC” of the Work section means the real-time monitor setup. Click the [Option PC] button on the “HOME” screen.

Page 138: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

12. Option System setup JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

132 DOC No. 7ZPNA4014

12.2. Setup procedure

1) Receive a setup data. Click the [Receive] button. 2) Input the setup data Select the output data to the real-time monitor. 3) Transmit the setup data Click the [Set] button.

12.3. Register Information Registrant information entered on the Log-in screen is displayed. Registrant information which is stored in the RCU is displayed at receiving the configuration data. Registrant information is updated to the data entered on the "Log in" screen after setting up.

12.4. IP Address The VDR/S-VDR outputs real-time data to the set-up IP address. 1) Option PC Input the IP address of monitor PC. 2)FGB2

The setup is required when the real-time monitor must receive the image data as three or four screens. Refer to the [Real time Monitor Installation] guide for details.

12.5. Real Time Monitor section Enter the check mark into the check box of necessary data. Usually, since all data are required by the real-time monitor, all effective channels are inputted check marks as default setup.

1) Sensor section

Only Connection CH can be set up. Enter a check mark into a check box of each channel which must output a NMEA monitor data. The NMEA sentence data of checked CH are outputted.

2) Audio

Enter a check mark into a check box of “AUDIO” for outputting an audio monitor data. 3) FGB1

Enter a check mark into a check box of “FGB1” for outputting an image monitor data from the VDR/S-VDR. 4) FGB2

This setup is required when the real-time monitor must receive the image data as three or four screens. Refer to the [Real time Monitor Installation] guide for details.

5) Enable button

When the [Enable] button is clicked, all monitor channels will become effective. A check mark is inputted into all check boxes.

6) Disable button

When the [Disable] button is clicked, all monitor channels will become null. A check mark is removed from all check boxes.

Page 139: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

13. ReportJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

133 DOC No. 7ZPNA4014

13. Report

When installation is completed, Create a result report using this function.

13.1. Starting

1) Click the [Report] button on the SYSTEM screen. “Report” screen will appear.

13.1.1. Report The report folder is created automatically. The report folder includes a setup file and so on as installation report.

The “Serial number of VDR/S-VDR (MBxxxxxx) _ VDR_report” folder is created on the Desktop of PC automatically.

Compress this folder, and upload the compressed files to the “Ship list” on the Marine service WEB.

Confirm the following items before logout when the installation is completed • System configuration file • FGB setup files for image capture • System status file • Event log files • Radar image file

Page 140: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

13. Report JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

134 DOC No. 7ZPNA4014

This page is intentionally left blank

Page 141: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

14. Program updateJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

135 DOC No. 7ZPNA4014

14. Program update Update the program of MCB, ARB RMB and FGB in the RCU.

14.1. Program update of MCB, ARB and RMB Update the program of MCB (CDJ-2304), ARB (CHA-387) and RMB (CDK-287).

14.1.1. Starting the Update application The application for update starts from the HOME screen. Select the [Update] button from the work section.

1) Click the [Update] button.

Page 142: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

14. Program update JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

136 DOC No. 7ZPNA4014

14.1.2. Select an update program (1. Program)

1) Select a program Select an update program with a program radio button. 2) Check a version of program Check a version number of present program. Click the [Version] button and the version number will appear. If it is the latest version, program update is not required.

14.1.3. Load a Program file (2. Program File) Load the update program file. Click the [Browse] button, and select the update program file.

14.1.4. Check IP address and Port number (3. Port) It is not necessary input the IP address and the Port number. Check the entry.

• MCB, ARB: 192.168.110.3 6000 • RMB: 192.168.60.3 6000

14.1.5. Update start (4. Update) Start to update the program. Click the [Update] button.

State of upload is displayed by progress bar and the message.

14.1.6. Update complete 1) Confirm that the update is completed. • Check that progress bar is complete till the end. • Check that” [END] Update Success” is displayed in the progress message

The RCU is restarted automatically and start operation with update program after the upload is complete. It is not necessary to reset up the system composition information by update.

2) Check the program version which was updated. Click the [Version] button and the version number will appear. 3) Quit the update application.

Page 143: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

14. Program updateJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

137 DOC No. 7ZPNA4014

14.2. Program update of FGB Update the program of FGB (CKA-137).

14.2.1. Preparation for FGB update The application for update starts from the “System” menu on the “System” screen. When the "Home" screen is displayed, click the [Installation] button to move to the "System" screen.

1) FGB WEB screen Click the [FGB Setup] from the “System” menu on the “System” screen. Internet Explorer (IE) starts and the root menu of the FGB WEB screen is displayed. 2) The FGB is made into SLEEP mode and program update is prepared. Click the [Sleep] button on the root menu. Confirm that a message in response dialog means “OK”.

Page 144: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

14. Program update JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

138 DOC No. 7ZPNA4014

3)Back the root menu Click the [Back] button of IE, and a display screen will be back to the root menu. * Do not click the [renew] button.

14.2.2. Starting the FGB Update application Start the FGB update application. Click the [FGB Update] button from the “System” menu on the “System” screen.

14.2.3. Program file

Select a program file for update. Click the [Browse] button, and select the program file for update.

14.2.4. Check a IP address and Port number It is not necessary input the IP address and the Port number.

Check the entry. ・ FGB: 192.168.110.151 80

14.2.5. Update start Start to update the program. Click the [Execute] button.

State of upload is displayed by progress bar and the message.

14.2.6. Update complete 1) Confirm that the update is completetd.1 • Check that “Application write OK” is displayed in the message window. 2) Quit the update application. 2) Reboot the RCU by AC power OFF and ON. 3) Click the [renew] button on the FGB WEB root menu of the IE.

Check the program version which was updated.

Page 145: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

15. Playback Software setupJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

139 DOC No. 7ZPNA4014

15. Playback Software setup

15.1. How to play back downloaded data from the Capsule with Ethernet

Show the flow from setup to playback below.

Stop recording to capsule.

Download data from VDR/S-VDR by Download software. Set information required for playback with Setup software.

Start the Playback software.

15.1.1. Download data from the Capsule by Download software (1) Click the [DOWNLOAD] button, start the Download software.

(2) Download software screen indicates.

Page 146: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

15. Playback Software setup JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

140 DOC No. 7ZPNA4014

(3) Select a save place with Folder selection button, and then select a playlist.

When download is started, playlists (from playlist1 to playlist10) are created automatically under the save place. It is possible to save maximum 9 download data under the playlist folder except playlist1.

(4) Set download value with the slide bar.

(5) Input check in the check box of necessary download data and click the [Start] button.

The Setup Folder screen opens, and please input a certain save folder if necessary. As default, date folder is indicated. Click the [OK] button, and download starts.

(6) If the following screen is indicated, download is completed. Click the [OK] button, and close the Download software.

Folder Composition Save Place

Save folder Playlist1 Playlist2 VDR Init Log Audio Visual Event Wav

Playlist3

Playlist10

Page 147: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

15. Playback Software setupJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

141 DOC No. 7ZPNA4014

15.1.2. Set information required for playback with Setup software

(1) Click the [SETUP] button, and start the Setup software.

(2) The Login screens is indicated, and click the [OK] button after confirming that user is selected in the Operator block.

(3) To import VDR/S-VDR configuration data, select the following file in the download data and click the [Import] button.

*: ¥Playlist2¥VDR¥Init¥SysInfo.dat

(4) Click the [Folder Selection] button, and select a folder created in accordance with the “3.1.3 Download data

from VDR/S-VDR by Download software”.

(5) Click the [Set] button, and setup is completed. To close the Setup software, click the [Close] button.

Download folder

Page 148: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

15. Playback Software setup JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

142 DOC No. 7ZPNA4014

15.1.3. Start the Playback Software

(1) Click the [PLAYBACK] button from Launcher menu, and start the Playback software.

Page 149: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

15. Playback Software setupJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

143 DOC No. 7ZPNA4014

15.2. How to play back CF card data in VDR/S-VDR

In order to play back record data of CF card, it is necessary to create a playback folder in the computer of use advance, and to copy the data.

Show the flow from setup to playback below.

Create a playback folder by My Computer before Setup.

Set required information for playback with Setup software.

Start the Playback software, and copy a record data of CF card.

15.2.1. Create a playback folder (1) To create a playback folder, start My Computer. (2) Create a folder as follows.

Playback data is copied to the folder made here. C:¥MV JRC

↑ E.g. Ship name

15.2.2. Set required information for playback with the Setup software (1) To start the Setup software, click the [SETUP] button.

(2) The Login screen is indicated, and click the [OK] button after confirming that user is selected in the Operator block.

Page 150: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

15. Playback Software setup JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

144 DOC No. 7ZPNA4014

(3) Eject a CF card from the VDR/S-VDR, and insert it into the CF card slot of used PC.

Then, to import VDR/S-VDR configuration data, select the following file in the CF card and click the [Import] button. CF card drive changes with used PC.

*: ¥Init¥SysInfo.dat

(4) Click the [Folder Selection] button, and select a folder created in accordance with the “3.1 Create a playback

folder”.

(5) Click the [Set] button, and setup is completed. To close the Setup software, click the [Close] button.

CF card drive

Page 151: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

15. Playback Software setupJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

145 DOC No. 7ZPNA4014

15.2.3. Copy a record data of CF card (1) Click the [PLAYBACK] button, and start the Playback software.

(2) Playback screen is indicated.

(3) Click the [Playlist] button on the Playback Operation Panel.

Playlist button

(4) Confirm the CF card drive is set in the Copy source. If the drive is not set, please click the [Folder Select] button and select the drive.

Page 152: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

15. Playback Software setup JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

146 DOC No. 7ZPNA4014

(5) Select a playlist in the Copy place, and click the [Copy] button.

(6) Select radio button of the playlist copied CF card data, and click the [OK] button.

(7) The setup is completion above, and it is possible to play back with the [Playback] button.

15.3. How to exit the Playback software

(1) Click the [Setup] button of bottom right in the playback screen and the Setup screen is indicated.

(2) Click the [Exit] button of bottom left in the Setup screen.

Setup button

Exit button

Page 153: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

16. InstallationJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

147 DOC No. 7ZPNA4014

16. Installation Installation procedure of the maintenance software for JCY-1800 / 1850

16.1. Uninstall the old version

If the old version is installed, install after deleting the old version from the”Control Panel” -”Add/remove Programs” of Windows.

16.2. Installation procedure

Down load the latest version on the Marine Service WEB.

1) Perform “setup.exe” Double-click the”setup.exe” file.

2) Start installer

When the [Next >] button appears, click it after displaying the following window.

3) Input the user information Input “jrcvdr” into the serial number block and click the [Next >] button.

Page 154: VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER · VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER Maintenance Software Instruction Manual ... JCY1800-maint.exe 2)

16. Installation JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

148 DOC No. 7ZPNA4014

4) Installation folder

“Program Files¥JRC¥JCY1800¥Maintenance” is specified as the installation folder. Click the [Next >] button.

5) Start installation Click the [Install] button to start the installation.

Click the [Finish] button.

9) Installing completion

The shortcut for the “Maintenance Software” of the JCY-1800 / 1850 will be placed on the desktop. Double-click it to start.