1
VOLTAGE TRANSDUCERS PHONE (614) 889-6152 TECH. ASSISTANCE (614) 876-8308 FAX # (614) 876-8538 4970 Scioto Darby Rd. Hilliard, Ohio 43026 Div. Morlan & Associates, Inc. WWW.FLEX-CORE.COM sales@flex-core.com 117 VOLTAGE TRANSDUCERS AC VOLTAGE TRANSDUCER MODEL 3AVT E167120 Accurate, reliable voltage measurement. Three separate inputs, three outputs. 2200Vac input/output isolation. UL, CUL, CE Listed. Designed for use in three phase applications which require inexpensive voltage measurement. 3AVT150 can be used with higher voltage potential transformers Line voltage monitoring. All Dimensions in Inches SPECIFICATIONS CONNECTION DIAGRAMS INPUT Frequency Range ....................................................... 50/60Hz Burden .....90V & 150V models.......................................... 1VA .................300V models .................................................... 2VA .................600V models .................................................... 3VA Overload ................................................................. F.S. Rating .................600V models .................................................. 575V Dielectric Test...(Input/Output/Case) ...........................2200Vac Instrument Power .................Std. 4-20mA units .. 115Vac, 50/60Hz, +15%, 10VA .................“-22” Option” ......... 230Vac, 50/60Hz, +15%, 10VA OUTPUT ACCURACY ........................................... +0.25% F.S. @60Hz ................ Includes effects of linearity (10-100%) and setpoint. Output Ripple......................................................... < 1.0% F.S. Response ...................................................................... 400ms Output Loading (Ohms) ...............1mA ............. A .............................................. 0-10K .................4-20mA ........ E ................................................ 0-1K .................4-20mA ........ E2 ......................... (@24Vdc)...0-600 ...............5V & 10V ..... C & CX5 .................................. > 10M Field Adjustable Cal......................................................... + 5% Temperature Effect ............................................... + 1.0% Rdg. Temperature Range ......................................... -20 O C to +60 O C CASE DIMENSIONS 1.50 4.75 0.25 0.25 3.63 1 3 2 4 1 3 2 4 1 23 4 CAL CAL CAL CASE HEIGHT 5.50" 2.3 Lbs. DIA. 0.38 (2 PLCS) ZERO ZERO ZERO PROTECTIVE GROUND (4 PLCS) DIA. 0.19 POINT Models A, C, CX5, & E2 1.50 4.75 0.25 0.25 3.63 12 34 56 6a 7 8 9 10 12a 12 11 ZERO CAL CASE HEIGHT 5.50" 2.3 Lbs. DIA. 0.38 (2 PLCS) PROTECTIVE GROUND (4 PLCS) DIA. 0.19 POINT THREE VOLTAGE TRANSDUCERS IN ONE ENCLOSURE Example: Three 0-120Vac Inputs with Three 0-1mA Outputs. 3AVT-150A ORDERING INFORMATION L2 L3 L1 1 6 5 4 3 2 11 10 9 8 7 12 6a 12a OUTPUT L1-L2 - + L2-L3 OUTPUT - + OUTPUT L3-L1 - + INST POWER TERMINALS 1, 3, AND 5 ARE INTERNALLY COMMON L2 L3 L1 1 6 5 4 3 2 11 10 9 8 7 12 6a 12a OUTPUT L1-N - + L2-N OUTPUT - + OUTPUT L3-N - + N INST POWER TERMINALS 1, 3, AND 5 ARE INTERNALLY COMMON 15-24Vdc - 15-24Vdc - 15-24Vdc L2 L3 L1 1 2 1 4 3 2 3 2 1 4 3 4 L R + OUTPUT L1-L2 - + L R OUTPUT L2-L3 + + R L L3-L1 OUTPUT + + 15-24Vdc - 15-24Vdc - 15-24Vdc L2 L3 L1 1 2 1 4 3 2 3 2 1 4 3 4 L R + OUTPUT L1-N - + L R OUTPUT L2-N + + R L L3-N OUTPUT + + N L2 L3 L1 L1-L2 1 - 2 1 4 3 2 + 3 2 1 4 3 4 OUTPUT OUTPUT L2-L3 - + - OUTPUT L3-L1 + L2 L3 L1 1 - 2 1 4 3 2 + 3 2 1 4 3 4 - + - + N OUTPUT L1-N OUTPUT L2-N L3-N OUTPUT A, C, & CX5 Three-Phase, Three-Wire A, C, & CX5 Three-Phase, Four -Wire E2 Three-Phase, Three-Wire E2 Three-Phase, Four-Wire E Three-Phase, Three-Wire E Three-Phase, Four-Wire LOAD LINE LOAD LINE LOAD LOAD LINE LOAD LINE LOAD LINE LINE Model E INPUT OPTIONAL OUTPUTS MODEL AVT- AC VOLTAGE 0-1mAdc* 4-20mAdc 4-20mAdc** 0-10Vdc* 0-5Vdc* 0-90 0-150 0-300 0-600 090A 150A 300A 600A 090E 150E 300E 600E 090E2 150E2 300E2 600E2 090C 150C 300C 600C 090CX5 150CX5 300CX5 600CX5 FEATURES APPLICATIONS *Models are self-powered from measured voltage line. ** E2 loop-powered models require 15-24Vdc. E (4-20mA) models require 115Vac instrument power. Optional 230Vac instrument power - Add suffix “-22”. “E” models are not CE listed. Transducer output is derived from the average absolute value of the input and calibrated as the RMS value of the sine wave input. NOTE: For an output that represents the average of the three inputs: Add Suffix “Y05” (Formerly X668) (Not UL, CUL, or CE Listed)

VOLTAGE TRANSDUCERSCASE DIMENSIONS 1.50 4.75 0.25 0.25 3.63 1 3 2 4 13 24 1 23 4 CAL CASE HEIGHT 5.50" 2.3 Lbs. DIA. 0.38 (2 PLCS) ZERO ZERO ZERO PROTECTIVE GROUND (4 PLCS) DIA. …

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: VOLTAGE TRANSDUCERSCASE DIMENSIONS 1.50 4.75 0.25 0.25 3.63 1 3 2 4 13 24 1 23 4 CAL CASE HEIGHT 5.50" 2.3 Lbs. DIA. 0.38 (2 PLCS) ZERO ZERO ZERO PROTECTIVE GROUND (4 PLCS) DIA. …

VOLTAGE TRANSDUCERS

PHONE (614) 889-6152TECH. ASSISTANCE (614) 876-8308

FAX # (614) 876-85384970 Scioto Darby Rd. Hilliard, Ohio 43026Div. Morlan & Associates, Inc.

[email protected]

117

VO

LTAG

E T

RA

NS

DU

CE

RS

AC VOLTAGE TRANSDUCER MODEL 3AVT

E167120

• Accurate, reliable voltage measurement.• Three separate inputs, three outputs.• 2200Vac input/output isolation.• UL, CUL, CE Listed.

• Designed for use in three phase applications whichrequire inexpensive voltage measurement.

• 3AVT150 can be used with higher voltage potential transformers

• Line voltage monitoring.

All Dimensions in Inches

SPECIFICATIONS

CONNECTION DIAGRAMS

INPUTFrequency Range ....................................................... 50/60HzBurden .....90V & 150V models .......................................... 1VA.................300V models .................................................... 2VA.................600V models .................................................... 3VAOverload ................................................................. F.S. Rating.................600V models .................................................. 575VDielectric Test...(Input/Output/Case) ...........................2200VacInstrument Power .................Std. 4-20mA units .. 115Vac, 50/60Hz, +15%, 10VA.................“-22” Option” ......... 230Vac, 50/60Hz, +15%, 10VAOUTPUTACCURACY ........................................... +0.25% F.S. @60Hz................ Includes effects of linearity (10-100%) and setpoint.Output Ripple ......................................................... < 1.0% F.S. Response ......................................................................400msOutput Loading (Ohms)...............1mA ............. A ..............................................0-10K

.................4-20mA ........ E ................................................0-1K

.................4-20mA ........ E2 ......................... (@24Vdc)...0-600...............5V & 10V ..... C & CX5 .................................. > 10M

Field Adjustable Cal. ........................................................ + 5% Temperature Effect ...............................................+ 1.0% Rdg.Temperature Range .........................................-20OC to +60OC

CASE DIMENSIONS

1.50

4.75 0.250.25

3.63

13

24

13

24

12

34

CAL CAL CAL

CASE HEIGHT 5.50"2.3 Lbs.

DIA. 0.38(2 PLCS)

ZERO ZERO ZERO PROTECTIVEGROUND

(4 PLCS)DIA. 0.19

POINT

Models A, C, CX5, & E2

1.50

4.75 0.250.25

3.63 1 2 3 4 5 6 6a

7 8 9 10 12a1211

ZERO CAL

CASE HEIGHT 5.50"2.3 Lbs.

DIA. 0.38(2 PLCS)PROTECTIVEGROUND

(4 PLCS)DIA. 0.19 POINT

THREE VOLTAGE TRANSDUCERS IN ONE ENCLOSURE

Example: Three 0-120Vac Inputswith Three 0-1mA Outputs.

3AVT-150A

ORDERING INFORMATION

L2L3

L1

1 65432 1110987 126a 12a

OUTPUTL1-L2- +

L2-L3OUTPUT

- +

OUTPUTL3-L1- + INST

POWER

TERMINALS 1, 3, AND 5 ARE INTERNALLY COMMON

L2L3

L1

1 65432 1110987 126a 12a

OUTPUTL1-N- +

L2-NOUTPUT

- +

OUTPUTL3-N- +

N

INST POWER

TERMINALS 1, 3, AND 5 ARE INTERNALLY COMMON

15-24Vdc- 15-24Vdc -

15-24Vdc

L2L3

L1

1 21432 32143 4

LR

+OUTPUT

L1-L2-

+

LROUTPUTL2-L3

++

RLL3-L1OUTPUT

+ +

15-24Vdc- 15-24Vdc -

15-24Vdc

L2L3

L1

1 21432 32143 4

LR

+OUTPUT

L1-N-

+LROUTPUT

L2-N

++RLL3-N

OUTPUT+ +

N

L2L3

L1

L1-L2

1

-

21432

+

32143 4

OUTPUT OUTPUTL2-L3- + -

OUTPUTL3-L1

+

L2L3

L1

1

-

21432

+

32143 4

- + - +

N

OUTPUTL1-N

OUTPUTL2-N L3-N

OUTPUT

A, C, & CX5 Three-Phase, Three-Wire

A, C, & CX5 Three-Phase, Four -Wire

E2 Three-Phase, Three-Wire

E2 Three-Phase, Four-Wire

E Three-Phase, Three-Wire

E Three-Phase, Four-Wire

LOA

D

LIN

E

LOA

D

LIN

E

LOA

D

LOA

D

LIN

E

LOA

D

LIN

E

LOA

D

LIN

ELI

NE

Model E

INPUT OPTIONAL OUTPUTS MODEL AVT-AC VOLTAGE 0-1mAdc* 4-20mAdc 4-20mAdc** 0-10Vdc* 0-5Vdc*

0-900-1500-3000-600

090A150A300A600A

090E150E300E600E

090E2150E2300E2600E2

090C150C300C600C

090CX5150CX5300CX5600CX5

FEATURES APPLICATIONS

*Models are self-powered from measured voltage line.** E2 loop-powered models require 15-24Vdc. E (4-20mA) models require 115Vac instrument power.Optional 230Vac instrument power - Add suffix “-22”.“E” models are not CE listed.

Transducer output is derived from the average absolute value of the input and calibrated as the RMS value of the sine wave input.

NOTE: For an output that represents the average of the three inputs: Add Suffix “Y05” (Formerly X668) (Not UL, CUL, or CE Listed)