VOLTAGE TRANSDUCERS
PHONE (614) 889-6152TECH. ASSISTANCE (614) 876-8308
FAX # (614) 876-85384970 Scioto Darby Rd. Hilliard, Ohio 43026Div. Morlan & Associates, Inc.
117
VO
LTAG
E T
RA
NS
DU
CE
RS
AC VOLTAGE TRANSDUCER MODEL 3AVT
E167120
• Accurate, reliable voltage measurement.• Three separate inputs, three outputs.• 2200Vac input/output isolation.• UL, CUL, CE Listed.
• Designed for use in three phase applications whichrequire inexpensive voltage measurement.
• 3AVT150 can be used with higher voltage potential transformers
• Line voltage monitoring.
All Dimensions in Inches
SPECIFICATIONS
CONNECTION DIAGRAMS
INPUTFrequency Range ....................................................... 50/60HzBurden .....90V & 150V models .......................................... 1VA.................300V models .................................................... 2VA.................600V models .................................................... 3VAOverload ................................................................. F.S. Rating.................600V models .................................................. 575VDielectric Test...(Input/Output/Case) ...........................2200VacInstrument Power .................Std. 4-20mA units .. 115Vac, 50/60Hz, +15%, 10VA.................“-22” Option” ......... 230Vac, 50/60Hz, +15%, 10VAOUTPUTACCURACY ........................................... +0.25% F.S. @60Hz................ Includes effects of linearity (10-100%) and setpoint.Output Ripple ......................................................... < 1.0% F.S. Response ......................................................................400msOutput Loading (Ohms)...............1mA ............. A ..............................................0-10K
.................4-20mA ........ E ................................................0-1K
.................4-20mA ........ E2 ......................... (@24Vdc)...0-600...............5V & 10V ..... C & CX5 .................................. > 10M
Field Adjustable Cal. ........................................................ + 5% Temperature Effect ...............................................+ 1.0% Rdg.Temperature Range .........................................-20OC to +60OC
CASE DIMENSIONS
1.50
4.75 0.250.25
3.63
13
24
13
24
12
34
CAL CAL CAL
CASE HEIGHT 5.50"2.3 Lbs.
DIA. 0.38(2 PLCS)
ZERO ZERO ZERO PROTECTIVEGROUND
(4 PLCS)DIA. 0.19
POINT
Models A, C, CX5, & E2
1.50
4.75 0.250.25
3.63 1 2 3 4 5 6 6a
7 8 9 10 12a1211
ZERO CAL
CASE HEIGHT 5.50"2.3 Lbs.
DIA. 0.38(2 PLCS)PROTECTIVEGROUND
(4 PLCS)DIA. 0.19 POINT
THREE VOLTAGE TRANSDUCERS IN ONE ENCLOSURE
Example: Three 0-120Vac Inputswith Three 0-1mA Outputs.
3AVT-150A
ORDERING INFORMATION
L2L3
L1
1 65432 1110987 126a 12a
OUTPUTL1-L2- +
L2-L3OUTPUT
- +
OUTPUTL3-L1- + INST
POWER
TERMINALS 1, 3, AND 5 ARE INTERNALLY COMMON
L2L3
L1
1 65432 1110987 126a 12a
OUTPUTL1-N- +
L2-NOUTPUT
- +
OUTPUTL3-N- +
N
INST POWER
TERMINALS 1, 3, AND 5 ARE INTERNALLY COMMON
15-24Vdc- 15-24Vdc -
15-24Vdc
L2L3
L1
1 21432 32143 4
LR
+OUTPUT
L1-L2-
+
LROUTPUTL2-L3
++
RLL3-L1OUTPUT
+ +
15-24Vdc- 15-24Vdc -
15-24Vdc
L2L3
L1
1 21432 32143 4
LR
+OUTPUT
L1-N-
+LROUTPUT
L2-N
++RLL3-N
OUTPUT+ +
N
L2L3
L1
L1-L2
1
-
21432
+
32143 4
OUTPUT OUTPUTL2-L3- + -
OUTPUTL3-L1
+
L2L3
L1
1
-
21432
+
32143 4
- + - +
N
OUTPUTL1-N
OUTPUTL2-N L3-N
OUTPUT
A, C, & CX5 Three-Phase, Three-Wire
A, C, & CX5 Three-Phase, Four -Wire
E2 Three-Phase, Three-Wire
E2 Three-Phase, Four-Wire
E Three-Phase, Three-Wire
E Three-Phase, Four-Wire
LOA
D
LIN
E
LOA
D
LIN
E
LOA
D
LOA
D
LIN
E
LOA
D
LIN
E
LOA
D
LIN
ELI
NE
Model E
INPUT OPTIONAL OUTPUTS MODEL AVT-AC VOLTAGE 0-1mAdc* 4-20mAdc 4-20mAdc** 0-10Vdc* 0-5Vdc*
0-900-1500-3000-600
090A150A300A600A
090E150E300E600E
090E2150E2300E2600E2
090C150C300C600C
090CX5150CX5300CX5600CX5
FEATURES APPLICATIONS
*Models are self-powered from measured voltage line.** E2 loop-powered models require 15-24Vdc. E (4-20mA) models require 115Vac instrument power.Optional 230Vac instrument power - Add suffix “-22”.“E” models are not CE listed.
Transducer output is derived from the average absolute value of the input and calibrated as the RMS value of the sine wave input.
NOTE: For an output that represents the average of the three inputs: Add Suffix “Y05” (Formerly X668) (Not UL, CUL, or CE Listed)