2
Quick Reference 930502H © 2015, CyberData Corporation, ALL RIGHTS RESERVED © 2015, CyberData Corporation, ALL RIGHTS RESERVED 930502H Quick Reference Wall Mounting Options Gang Box Mounting Options Backplate Wall (Not Provided) Network Cable & for Ground Wire Connection Pick One of Four Mounting Hole Screw 121001A Accessory Kit (4 Places) on Wall Pre Drill Holes Ground Wire Cutout Mounting Screw (3x) Slot Entry Cable Closed Slots Cable Two Gang Box use four Wall Cutout or Two Gang Box Backplate accept Single Gang Box Single Gang Box use two Backplate Wall Cutout 121002B Screw Accessory Kit Mounting Screw (3x) (Not Provided) Ground Wire Any Available Mounting Hole Ground Wire Connect to (Not Provided) Network Cable Slot Entry Cable Closed Slots Cable Getting Started Download the VoIP V3 Indoor Intercom Operations Guide PDF file from the following web page: http://www.cyberdata.net/products/voip/digitalanalog/intercomindoorv3/docs.html Create a plan for the locations of your Intercoms. WARNING: This product should be installed by a licensed electrician according to all local electrical and building codes. WARNING: To prevent injury, this apparatus must be securely attached to the floor/wall in accordance with the installation instructions. WARNING: The PoE connector is intended for intra-building connections only and does not route to the outside plant. WARNING: This enclosure is not rated for any AC voltages! Parts Contacting CyberData Parameter Factory Default Setting IP Addressing DHCP IP Address a 10.10.10.10 Web Access Username admin Web Access Password admin Subnet Mask a 255.0.0.0 Default Gateway a 10.0.0.1 a. Default if there is not a DHCP server present. (4) Plastic Ribbed Anchor (4) #6-32 FlatHead Countersunk Machine Screw (1) Wall Mounting Kit (1) Intercom Assembly (1) Gang Box Mounting Kit (4) Sheet Metal Screw Sales: (831) 373-2601 ext. 334 Support: 831-373-2601 ext. 333 Support Website: http://support.cyberdata.net/ RMA Department: (831) 373-2601 ext. 136 RMA Email: [email protected] RMA Status: http://support.cyberdata.net/ Warranty Information: http://support.cyberdata.net/ Corporate Headquarters CyberData Corporation 3 Justin Court Monterey, CA 93940, USA Phone: 831-373-2601 Fax: 831-373-4193 http://www.cyberdata.net/ The IP Endpoint Company Installation Quick Reference VoIP V3 Indoor Intercom SIP Compliant 011211*, RAL 9003, Signal White *Replaces the 011111 number.

VoIP V3 Indoor Intercom - CyberData Corporationfiles.cyberdata.net/assets/011211/011211_930502H_V...© 2015, CyberData Corporation, ALL RIGHTS RESERVED 930502H Quick Reference Quick

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: VoIP V3 Indoor Intercom - CyberData Corporationfiles.cyberdata.net/assets/011211/011211_930502H_V...© 2015, CyberData Corporation, ALL RIGHTS RESERVED 930502H Quick Reference Quick

Quick Reference 930502H © 2015, CyberData Corporation, ALL RIGHTS RESERVED© 2015, CyberData Corporation, ALL RIGHTS RESERVED 930502H Quick Reference

Wall Mounting Options

Gang Box Mounting Options

Backplate

Wall

(Not Provided)

Network Cable &

for Ground Wire ConnectionPick One of Four Mounting Hole

Screw121001A

Accessory Kit

(4 Places) on WallPre Drill Holes

Ground Wire

Cutout

MountingScrew (3x)

SlotEntryCable

ClosedSlotsCable

Two Gang Box use four

Wall Cutout

or Two Gang Box

Backplate acceptSingle Gang Box

Single Gang Box use two

Backplate

Wall Cutout

121002BScrew Accessory Kit

MountingScrew (3x)

(Not Provided)Ground Wire

Any Available Mounting HoleGround Wire Connect to

(Not Provided)Network Cable

SlotEntryCable

ClosedSlotsCable

Getting Started• Download the VoIP V3 Indoor Intercom Operations Guide PDF file from the following web page:

http://www.cyberdata.net/products/voip/digitalanalog/intercomindoorv3/docs.html

• Create a plan for the locations of your Intercoms.

• WARNING: This product should be installed by a licensed electrician according to all local electrical and building codes.

• WARNING: To prevent injury, this apparatus must be securely attached to the floor/wall in accordance with the installation instructions.

• WARNING: The PoE connector is intended for intra-building connections only and does not route to the outside plant.

• WARNING: This enclosure is not rated for any AC voltages!

Parts

Contacting CyberData

Parameter Factory Default Setting

IP Addressing DHCP

IP Addressa 10.10.10.10

Web Access Username admin

Web Access Password admin

Subnet Maska 255.0.0.0

Default Gatewaya 10.0.0.1

a. Default if there is not a DHCP server present.

(4) Plastic Ribbed Anchor (4) #6-32 FlatHead Countersunk Machine Screw

(1) Wall Mounting Kit(1) Intercom Assembly (1) Gang Box Mounting Kit

(4) Sheet Metal Screw

Sales: (831) 373-2601 ext. 334Support: 831-373-2601 ext. 333Support Website: http://support.cyberdata.net/RMA Department: (831) 373-2601 ext. 136RMA Email: [email protected] Status: http://support.cyberdata.net/Warranty Information: http://support.cyberdata.net/

Corporate Headquarters

CyberData Corporation3 Justin CourtMonterey, CA 93940, USA

Phone: 831-373-2601Fax: 831-373-4193http://www.cyberdata.net/

The IP Endpoint Company

Installation Quick Reference

VoIP V3 Indoor IntercomSIP Compliant011211*, RAL 9003, Signal White*Replaces the 011111 number.

Page 2: VoIP V3 Indoor Intercom - CyberData Corporationfiles.cyberdata.net/assets/011211/011211_930502H_V...© 2015, CyberData Corporation, ALL RIGHTS RESERVED 930502H Quick Reference Quick

© 2015, CyberData Corporation, ALL RIGHTS RESERVED 930502H Quick Reference Quick Reference 930502H © 2015, CyberData Corporation, ALL RIGHTS RESERVED

RTFM Button

Dimensions

Maximum Recommended Wall Cutout Dimensions

SW1

When the device is operational and linked to a network, you can use the Reset Test Function Management (RTFM) button (SW1 [see picture]) to announce the device’s IP address or restore the device to the factorydefault settings.

To announce the device’s current IP address:

• Press and release the RTFM button within a five second window.

Note The device will use DHCP to obtain the new IP address (DHCP-assigned address or default to 10.10.10.10 if a DHCP server is not present).

To restore the device to factory default settings:

• Press and hold the RTFM button for longer than five seconds until you hear the device announce that it is restoring the factory default settings.

4.53 [115.0]

4.53 [115.0]2.22 [56.3]DIMENSIONS ARE IN INCHES [MILLIMETER]

Dimensions are in Inches [Millimeter]

Wall Cutout

0.25 [6.4]

0.25 [6.4]

0.25 [6.4]

0.25 [6.4]Top Cable Entry Closed

Top Cable Entry Opening

Cable Connections

Terminal Block Connections

to J2

021078D

Speaker to J7

Back Plate

Push-Button

to J6Microphone

PCBA

MountingScrews

MountingScrews

PCBA

J7

J6

J2

Wire (IN)Terminal Blockcan accept16 AWG wire

J3 Terminal Block

16

Alternate Power Input:1 = +8 to +12VDC @ 1000mA Regulated Power Supply*2 = Power Ground*

Relay Contact:(1 A at 30 VDC for continuous loads)3 = Normally Open Common4 = Normally Open Contact5 = Door Sense Input6 = Door Sense Ground Reference

*Contacts 1 and 2 on the J3 terminal block are only for powering the device from a non-PoE 12VDC power source as an alternative to Network PoE power. Use of these contacts for any other purpose will damage the device and void the product warranty.

3 4