Installation Guide Note to the installer ■ Before attempting to connect or operate this product, please read the label on the rear of the main monitor. Please read this guide carefully, and install the product safely and correctly by following the instructions. Carefully read the information found in the section titled "For your safety" in particular. Only use attachments/accessories specified by the manufacturer. The installation shall be carried out in accordance with all applicable installation rules. Panasonic assumes no responsibility for injuries or property damage resulting from failures arising out of improper installation or operation inconsistent with this guide. Additionally, any resulting malfunction will not be covered under the warranty. ■ After installation, make sure to leave this guide with the customer. For the Installation of door station and main monitor station • VL-V554EX is a surface mount type, VL-V554UEX is a flush mount type. For your safety To prevent severe injury and loss of life/property, read this section carefully before using the product to ensure proper and safe operation of your product. WARNING Preventing fire, electric shock and short circuits ● Leave installation work to the dealer. Installation work requires technique and experiences. Failure to observe this may cause fire, electric shock, injury, or damage to the product. Consult the dealer. ● Electrical connection work should be performed by certified personnel only. Certification is required for performing electrical connection work. Consult your dealer. ● Use only the specified power supply unit. ● Do not attempt to disassemble or modify this product. Contact an authorised service centre for repairs. ● Never install wiring during a lightning storm. ● Do not connect non-specified devices. ● Do not connect a power cable to a terminal that is not specified in this guide. ● When opening holes in walls for installation or wiring, or when securing the power cable, make sure you do not damage existing wiring and ductwork. ● Do not make any wiring connections when the power supply is turned on. ● Do not use the supplied power supply unit for outdoor installations (it is for indoor use only). ● Do not install the main monitor and power supply unit in the following places: - Places where the main monitor and power supply unit may be splashed with water or chemicals. - Places where there is a high concentration of dust, or high humidity. ● Do not perform any actions (such as fabricating, twisting, stretching, bundling, forcibly bending, damaging, altering, exposing to heat sources, or placing heavy objects on the power cable) that may damage the power cable. Using the product with a damaged power cable may cause electric shock, short circuits, or fire. Contact an authorised service centre for repairs. ● When existing chime wires are used, it is possible that they contain AC voltage. Contact an authorised service centre. ● Do not install or use the product in health care facilities if any regulations posted in the area instruct you not to do so. Hospitals or health care facilities may be using equipment that could be sensitive to external RF (radio frequency) energy. ● Do not install or use this product near automatically controlled devices such as automatic doors and fire alarms. Radio waves emitted from this product may cause such devices to malfunction, resulting in an accident. Preventing accidents and injuries CAUTION ● If the wiring is underground, do not make any connections underground. ● If the wiring is underground, use a protection tube. ● If the wiring is outdoors, use a protection tube or a surge protector. ● Install the product securely adhering to the instructions in this guide to prevent it from falling off the wall. Avoid installing onto low-strength walls, such as gypsum board, ALC (autoclaved lightweight concrete), concrete block, or veneer (less than 18 mm thick) walls. Preventing electric shock Preventing injury 1-62, 4-chome, Minoshima, Hakata-ku, Fukuoka 812-8531, Japan © Panasonic System Networks Co., Ltd. 2013 PNQW3982ZA PC1113MT1113 VL-V554EX/ VL-V554UEX VL-MWD501EX Door station Main monitor station Door station is described as "doorphone" and Main monitor station is described as "main monitor" in this guide. Model No. VL-SWD501EX VL-SWD501UEX Wireless Video Intercom System To avoid malfunction or communication disturbances, do not install the doorphone or the main monitor in the following locations: - Places where vibration or any other kind of impact occurs. - Places where echoing is frequent. - Places near a high concentration of dust, hydrogen sulphide, ammonia, sulphur, or noxious fumes. For the doorphone ● If a strong light is shining on the doorphone, the visitor’s face may not be distinguishable. Do not place the doorphone in the following locations: - Where most of the background is the sky. - Where the background is a white wall, and direct sunlight will reflect off it. - Where direct sunlight will shine on the doorphone. ● Do not place the doorphone in locations where echoing occurs, as this will cause the doorphone to beep frequently. ● Dust protection/water protection is IP54. Only when installation work specified in this guide is properly performed and appropriate water protection treatment is performed. ● Make sure the rear of the doorphone is not subject to water. ● Depending on the installation location, condensation may form on the doorphone’s lens cover. This may cause images to become obscured. Condensation will dissipate as the temperature rises. For the main monitor ● Install the main monitor away from electronic appliances such as TVs, radios, personal computers, air conditioners, boiler control panels with intercom, home security equipment, wireless devices, or digital cordless phones. ● Do not install the main monitor in places where it will be affected by extremely high-frequency radio waves (near broadcasting antennas etc.). This may cause the display to flicker or an interrupting noise to occur. ●Leave at least 20 cm of space above, below, and to the left and right sides of the main monitor. Do not install on a wall that is deeply recessed. ● Do not install the main monitor inside a wall. ● Be sure to install the main monitor more than 5 m away from the doorphone. ● The product operates in the frequency range of 1.88 GHz to 1.90 GHz, and the RF transmission power is 250 mW (max.). Refer to the "For best performance" section in the Operating Instructions. ● In areas surrounded by a high electrical field, disturbances may occur in the main monitor’s image or sound. Supplied accessories for installation ■ For the doorphone (EX only) Mounting base × 1 (UEX only) Flush mounting box × 1 Screw × 4 (Used when installing the doorphone) (EX : 4 mm x 12 mm) (UEX : 4 mm x 25 mm) Name plate × 2 (incl. 1 spare) Hex wrench × 1 ■ For the main monitor Mounting bracket × 1 Cable binder × 1 ■ Power supply unit and related items Power supply unit × 1 (Part No. VL-PS240) Cable binder × 2 Important: You will need the following additional items to install and configure the doorphone and the main monitor. [Locally procured] - Screws (for mounting base: × 2, for mounting bracket: × 2): Prepare the screws ( the drawing on the right) according to the material, structure, strength and other factors of the mounting area and the total weight of objects to be mounted. - Power cables (AC/DC cables), wires (for doorphone and other connections): Prepare cables and wires of the appropriate specification. ( "Wire type and length") Note: ● The illustrations in the supplied manual(s) may vary slightly from the actual product. 4 mm Precautions for installation Wiring schematic diagram Set up correctly according to the following wiring schematic diagram and "Wire type and length". ● For information, such as order numbers, about optional devices that can be connected to, refer to the "Additional/replacement accessories" section in the Operating Instructions. MAIN MONITOR DOORPHONE 1 DOORPHONE 2 POWER SUPPLY UNIT 220-240 V AC Connection device for option output (A contact) *1 Make sure to only connect electric vehicle gate locks to the S3/S4 terminals of the doorphones. *2 Make sure to only connect electric door locks to the S1/S2 terminals of the doorphones. NP: Non-polarised Power supply Power supply Power supply Power supply 12 V AC/DC 12 V AC/DC 12 V AC/DC 12 V AC/DC Electric lock (Electric vehicle gate lock) *1 Electric lock (Electric door lock) *2 Electric lock (Electric door lock) *2 Electric lock (Electric vehicle gate lock) *1 24 V DC Wire type and length Wiring run Wire type *1 Diameter Length (Max.) Main monitor – Doorphone A φ 0.65 mm 22 AWG 100 m φ 1.0 mm 18 AWG 130 m φ 0.5 mm CAT 5 50 m Main monitor – Power supply unit B φ 0.65 mm 22 AWG 10 m φ 1.0 mm 18 AWG 20 m Power supply unit – AC power source C φ 1.2 mm - φ 2.0 mm (17 AWG - 12 AWG) No requirement Doorphone – Electric lock *2 D φ 0.5 mm - φ 1.2 mm (24 AWG - 17 AWG) According to specifi- cation of connected device. Main monitor – Connection device for option output (A contact) *2 E φ 0.5 mm - φ 1.2 mm (24 AWG - 17 AWG) According to specifi- cation of connected device. *1 Type: Single-pair cable with outer sheath (jacket) Conductor: Copper solid ● A certified power supply wiring has to be used with this equipment. The relevant national installation and/or equipment regulations shall be considered. A certified power supply wiring not lighter than ordinary polyvinyl chloride flexible wiring according to IEC 60227 shall be used. *2 When using an electric lock or a connection device for option output (A contact), select a device that meets the following guidelines: ● Electric lock connection terminal (S1/S2, S3/S4): - N/O dry closure contact - 12 V AC/DC, less than 1 A ● Connection device for option output (A contact) terminal (OUT1/OUT2): - 24 V AC/DC, less than 0.3 A (minimum contact: 5 V DC 1 mA) A D D E B C NP NP NP NP NP NP NP NP

VL-SWD501UEX MAIN MONITOR

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: VL-SWD501UEX MAIN MONITOR

Installation Guide

Note to the installer■ Beforeattemptingtoconnectoroperatethisproduct,pleasereadthelabelontherearofthemainmonitor.

■ Pleasereadthisguidecarefully,andinstalltheproductsafelyandcorrectlybyfollowingtheinstructions.Carefullyreadtheinformationfoundinthesectiontitled"Foryoursafety"inparticular.

■ Onlyuseattachments/accessoriesspecifiedbythemanufacturer.■ Theinstallationshallbecarriedoutinaccordancewithallapplicableinstallationrules.■ Panasonicassumesnoresponsibilityforinjuriesorpropertydamageresultingfromfailuresarisingoutofimproperinstallationoroperationinconsistentwiththisguide.Additionally,anyresultingmalfunctionwillnotbecoveredunderthewarranty.

■ Afterinstallation,makesuretoleavethisguidewiththecustomer.

For the Installation of door station and main monitor station

•VL-V554EXisasurfacemounttype,VL-V554UEXisaflushmounttype.

For your safetyTopreventsevereinjuryandlossoflife/property,readthissectioncarefullybeforeusingtheproducttoensureproperandsafeoperationofyourproduct.

WARNINGPreventingfire,electricshockandshortcircuits● Leaveinstallationworktothedealer.Installationworkrequirestechniqueandexperiences.Failuretoobservethismaycausefire,electricshock,injury,ordamagetotheproduct.Consultthedealer.● Electricalconnectionworkshouldbeperformedbycertifiedpersonnelonly.Certificationisrequiredforperformingelectricalconnectionwork.Consultyourdealer.● Useonlythespecifiedpowersupplyunit.● Donotattempttodisassembleormodify thisproduct.Contactanauthorisedservicecentreforrepairs.● Neverinstallwiringduringalightningstorm.● Donotconnectnon-specifieddevices.● Donotconnectapowercabletoaterminalthatisnotspecifiedinthisguide.●Whenopeningholes inwalls for installationorwiring,orwhensecuring thepowercable,makesureyoudonotdamageexistingwiringandductwork.● Donotmakeanywiringconnectionswhenthepowersupplyisturnedon.● Donotusethesuppliedpowersupplyunitforoutdoorinstallations(itisforindooruseonly).● Donotinstallthemainmonitorandpowersupplyunitinthefollowingplaces:- Placeswherethemainmonitorandpowersupplyunitmaybesplashedwithwaterorchemicals.- Placeswherethereisahighconcentrationofdust,orhighhumidity.● Donotperformanyactions(suchasfabricating,twisting,stretching,bundling,forciblybending,damaging,altering,exposingtoheatsources,orplacingheavyobjectsonthepowercable) thatmaydamagethepowercable.Usingtheproductwithadamagedpowercablemaycauseelectricshock,shortcircuits,or fire.Contactanauthorisedservicecentreforrepairs.●Whenexistingchimewiresareused, it ispossible that theycontainACvoltage.Contactanauthorisedservicecentre.

● Donot installorusetheproduct inhealthcare facilities ifanyregulationsposted inthearea instructyounot todoso.Hospitalsorhealthcare facilitiesmaybeusingequipmentthatcouldbesensitivetoexternalRF(radiofrequency)energy.● Donot install oruse thisproductnearautomatically controlleddevicessuchasautomaticdoorsandfirealarms.Radiowavesemitted fromthisproductmaycausesuchdevicestomalfunction,resultinginanaccident.

Preventingaccidentsandinjuries

CAUTION

● Ifthewiringisunderground,donotmakeanyconnectionsunderground.● Ifthewiringisunderground,useaprotectiontube.● Ifthewiringisoutdoors,useaprotectiontubeorasurgeprotector.

● Install theproductsecurelyadhering to the instructions in thisguide toprevent it fromfallingoff thewall.Avoid installingonto low-strengthwalls,suchasgypsumboard,ALC(autoclavedlightweightconcrete),concreteblock,orveneer(lessthan18mmthick)walls.

Preventingelectricshock

Preventinginjury

1-62,4-chome,Minoshima,Hakata-ku,Fukuoka812-8531,Japan

©PanasonicSystemNetworksCo.,Ltd.2013PNQW3982ZA PC1113MT1113

VL-V554EX/VL-V554UEX

VL-MWD501EX

Doorstation Mainmonitorstation

Doorstationisdescribedas"doorphone"andMainmonitorstationisdescribedas"mainmonitor"inthisguide.

ModelNo. VL-SWD501EXVL-SWD501UEX

Wireless Video Intercom System

Toavoidmalfunctionorcommunicationdisturbances,donotinstallthedoorphoneorthemainmonitorinthefollowinglocations:- Placeswherevibrationoranyotherkindofimpactoccurs.- Placeswhereechoingisfrequent.- Placesnearahighconcentrationofdust,hydrogensulphide,ammonia,sulphur,ornoxiousfumes.

■ For the doorphone● Ifastronglightisshiningonthedoorphone,thevisitor’sfacemaynotbedistinguishable.Donotplacethedoorphoneinthefollowinglocations:- Wheremostofthebackgroundisthesky.- Wherethebackgroundisawhitewall,anddirectsunlightwillreflectoffit.- Wheredirectsunlightwillshineonthedoorphone.

● Donotplace thedoorphone in locationswhereechoingoccurs,as thiswill cause thedoorphonetobeepfrequently.● Dustprotection/waterprotectionisIP54.Onlywheninstallationworkspecifiedinthisguideisproperlyperformedandappropriatewaterprotectiontreatmentisperformed.●Makesuretherearofthedoorphoneisnotsubjecttowater.● Dependingontheinstallationlocation,condensationmayformonthedoorphone’slenscover.Thismaycauseimagestobecomeobscured.Condensationwilldissipateasthetemperaturerises.

■ For the main monitor● Install themainmonitoraway fromelectronicappliancessuchasTVs, radios,personalcomputers,airconditioners,boilercontrolpanelswith intercom,homesecurityequipment,wirelessdevices,ordigitalcordlessphones.● Donotinstallthemainmonitorinplaceswhereitwillbeaffectedbyextremelyhigh-frequencyradiowaves(nearbroadcastingantennasetc.).Thismaycausethedisplaytoflickeroraninterruptingnoisetooccur.● Leaveat least20cmofspaceabove,below,and to the leftand rightsidesof themainmonitor.Donotinstallonawallthatisdeeplyrecessed.● Donotinstallthemainmonitorinsideawall.● Besuretoinstallthemainmonitormorethan5mawayfromthedoorphone.● Theproduct operates in the frequency rangeof 1.88GHz to 1.90GHz, and theRFtransmissionpower is250mW(max.).Refer to the"Forbestperformance"section in theOperatingInstructions.● Inareassurroundedbyahighelectricalfield,disturbancesmayoccur inthemainmonitor’simageorsound.

Supplied accessories for installation■ For the doorphone

(EXonly)

Mountingbase×1

(UEXonly)

Flushmountingbox×1

Screw×4(Usedwheninstallingthedoorphone)(EX:4mmx12mm)(UEX:4mmx25mm)

Nameplate×2(incl.1spare) Hexwrench×1

■ For the main monitor

Mountingbracket×1

Cablebinder×1

■ Power supply unit and related items

Powersupplyunit×1

(PartNo.VL-PS240)Cablebinder×2

Important: ●You will need the following additional items to install and configure the doorphone and the main monitor. [Locally procured]- Screws(formountingbase:×2,formountingbracket:×2):Preparethescrews( thedrawingontheright)accordingtothematerial,structure,strengthandotherfactorsofthemountingareaandthetotalweightofobjectstobemounted.- Powercables(AC/DCcables),wires(fordoorphoneandotherconnections):Preparecablesandwiresoftheappropriatespecification.( "Wiretypeandlength")

Note:● Theillustrationsinthesuppliedmanual(s)mayvaryslightlyfromtheactualproduct.

4mm

Precautions for installation

Wiring schematic diagramSetupcorrectlyaccordingtothefollowingwiringschematicdiagramand"Wiretypeandlength".● Forinformation,suchasordernumbers,aboutoptionaldevicesthatcanbeconnectedto,refertothe"Additional/replacementaccessories"sectionintheOperatingInstructions.

MAIN MONITOR

DOORPHONE 1

DOORPHONE 2

POWER SUPPLY UNIT

220-240VAC

Connectiondeviceforoptionoutput(Acontact)

*1MakesuretoonlyconnectelectricvehiclegatelockstotheS3/S4terminalsofthedoorphones.

*2MakesuretoonlyconnectelectricdoorlockstotheS1/S2terminalsofthedoorphones.

NP: Non-polarised

Powersupply

Powersupply

Powersupply

Powersupply

12VAC/DC

12VAC/DC

12VAC/DC

12VAC/DC

Electriclock(Electricvehiclegatelock)*1

Electriclock(Electricdoorlock)*2

Electriclock(Electricdoorlock)*2

Electriclock(Electricvehiclegatelock)*1

24VDC

Wire type and length

WiringrunWiretype*1

Diameter Length(Max.)

Mainmonitor–Doorphone

A

φ0.65mm 22AWG 100m

φ1.0mm 18AWG 130m

φ0.5mm CAT5 50m

Mainmonitor–Powersupplyunit

Bφ0.65mm 22AWG 10m

φ1.0mm 18AWG 20m

Powersupplyunit–ACpowersource

C φ1.2mm-φ2.0mm(17AWG-12AWG) Norequirement

Doorphone–Electriclock*2

D φ0.5mm-φ1.2mm(24AWG-17AWG)

Accordingtospecifi-cationofconnected

device.

Mainmonitor–Connectiondeviceforoption

output(Acontact)*2E φ0.5mm-φ1.2mm

(24AWG-17AWG)

Accordingtospecifi-cationofconnected

device.

*1Type:Single-paircablewithoutersheath(jacket)Conductor:Coppersolid● Acertifiedpowersupplywiringhastobeusedwiththisequipment.Therelevantnationalinstallationand/orequipmentregulationsshallbeconsidered.AcertifiedpowersupplywiringnotlighterthanordinarypolyvinylchlorideflexiblewiringaccordingtoIEC60227shallbeused.

*2Whenusinganelectriclockoraconnectiondeviceforoptionoutput(Acontact),selectadevicethatmeetsthefollowingguidelines:● Electriclockconnectionterminal(S1/S2,S3/S4):- N/Odryclosurecontact- 12VAC/DC,lessthan1A

●Connectiondeviceforoptionoutput(Acontact)terminal(OUT1/OUT2):- 24VAC/DC,lessthan0.3A(minimumcontact:5VDC1mA)

A D

DE

B

C

NP

NPNP

NP

NP

NP

NP

NP

Page 2: VL-SWD501UEX MAIN MONITOR

ScrewA

Youcanusethe[Wide/Zoomsettings]settingonthemainmonitortoselecttheareathatisvisiblewhenavisitorcalls;availablesettingsare[Wide],[Zoom],and[All](entireimagedisplay).(Defaultsetting:[Wide])

● Thefollowingvaluesareforwhenthedoorphoneisinstalledinthestandardposition(thecentreof thedoorphone’sheight isapproximately1,450mm)andatadistanceofapproximately500mmfromthecameralens.

■ Installation height and area visible by the camera lens

When set to zoom

Displaysaportionofthewideimageat2timesthesize.● Becauseadigital zoom isused, the imagequalityof zoomdisplayislowerthanthatofwidedisplayorentireimagedisplay.

Imagedisplayedonmainmonitor:

● Youcanusethemainmonitor’s [Zoompositionsettings]settingtoselect thedesiredareavisiblewhenzooming.Refertothefollowingandconfigurethemainmonitor.

Entire image display

Theareaaboveandbelowthewideimageisvisible.

Important:● Onthebottomsurfaceofthedoorphoneandthemountingbase,thereareholestoallowwatertodrain.Donotcoverthemupwheninstalling.●Whenexistingwiring(suchaschimewires)isused:- ItmaycontainACvoltagethatmaycauseelectricshockand/ordamagetheproduct.- Neverusethefollowingtypesofwiring.Consultaqualifiedtechnician/dealer.

VL-V554EX VL-V554UEX

1 Attachthemountingbasetothewallsecurely.

Mountingbase(accessory)

Wire(locallyprocured)

Wall

83.5mm

Screws(locallyprocured)×2

● Installthemountingbaseonaverticalflatwall.

1 Installtheflushmountingboxinthewall.

Flushmountingbox(accessory)

100mmKnockouthole*1

151mm

37mm

*1Onlyopentheknockoutholesasrequiredforthewiring.

2 Useahexwrench(accessory)toloosenscrewAandremovethefrontpanelofthedoor-phone.

ScrewA

Frontpanel

2mmhexwrench (accessory)

3 Connectthewires.

Terminalforthemainmonitor

<Rear view>

Terminalsfortheelectriclocks● Recommendedtorque:0.5N·m{5.1kgf·cm}●Maximumtorque:0.7N·m{7.1kgf·cm}

3-1Loosenthescrews.3-2Pushinthewirestotheterminalconnectors(non-polar),thentightenthescrews.

4 Attachthedoorphonetothemountingbase.

Screws(accessory)×4

4 Attachthedoorphonetotheflushmountingbox.

Screws(accessory)×4

5 AttachthenameplatetothedoorphoneandusescrewAtosecurethefrontpanel.●Writethenameonthenameplateasneeded.

Nameplate(accessory)

ScrewA ●Recommended torque:0.35N·m{3.6kgf·cm}

Approx.500

Approx.170°

Approx.2,250

Imagerange

Approx.115°

Approx.500

Imagedisplayedonmainmonitor:

Approx.1,600

Approx.650

Approx.1,450

Upanddown Leftandright(whenlookingfromabove)

Up ImagerangeApprox.2,050

Approx.500

Centreofdoorphone

Approx.45°

Centre (default)

Approx.45°

Approx.500

ImagerangeApprox.1,650

DownApprox.45°

Approx.500

Approx.1,400

Imagerange

Left

Approx.1,500Approx.1,450

Approx.550

Approx.1,450 Approx.1,250

Approx.400

Installing the doorphone■ About the installation location

● Thedevicemustbeinstalledinsideanelectricalpanelorcabinet.● Areadilyaccessibledisconnectdeviceshallbeincorporatedexternaltotheequipment.- Externaldisconnectdevicemustbecertifiedandhaveacreepageandclearancedistanceof3mmormore.

■ Precautions for wiring●Makesureyouturnoffthepoweratthebreakerbeforeperforminganywiringwork.● AlwaysconnectACorDCcables to theappropriateconnection terminals. IncorrectlyconnectingtheACorDCcablesmaydamagethepowersupplyunit.● Toprevent thepowercables fromdisconnectingandtopreventelectricshock,securethepowercablesusingthecablebinders(accessory)andattachthecablecovers.

How to connect the power cable (AC/DC)

1 StriptheAC/DCcablesasfollows:

7mm

45mm<ACcable>

<DCcable>25mm

7mm

2 Removethescrews(B)andthenremovethecablecovers(A).

3 ConnecttheAC/DCcabletotheACINterminal/DCOUTterminalonthetopandbottomofthepowersupplyunit,andthensecurethewiresbytighteningthescrews.

● Recommendedtorque:- ACterminal:0.4N·m{4.1kgf·cm}- DCterminal:0.45N·m{4.6kgf·cm}

<Frontview>ACcable*1

DCcable

Screws

*1

Cablebinders(accessory)

4 Usethecablebinders(accessory)tosecuretheAC/DCcables(double-coatedarea)tothepowersupplyunit.

5 Makesuretoreplacethecablecovers(A).

Connectthepowersupplyunit(accessory)andAC/DCcables(locallyprocured).

CAUTIONInsertthecablesfirmlyallthewayintotheterminals.Ifthecablesarenotinsertedalltheway,heatmaybegenerated.

*1Makesurethattherearenobarewiresexposedoutsidetheproduct.

Screws(B)Cablecovers(A)

DCOUTterminal

ACcablebinderhole

ACINterminal

<Topview>

<Bottomview>

DCcablebinderhole

Power supply unit (with cable covers removed)

Attach to the DIN rail

Attachintheorderdescribedbelowsothathook(b)ispositionedatthebottom.

1 Hanghook(a)ontheDINrail(A).

2 Pullandholdtheleverdown(B).

3 Securehook(b)totheDINrail(C).

Hook(a)

A

B

C

Hook(b)

Main monitor installation position

Installing the main monitor

Mainmonitorinstallationposition

82.5mm

82.7mm

2 ConnecttheDCcableandwires.

● Connect thewirescorrectlyaccording to"Wiringschematicdiagram".

3 Mountthemainmonitortothemountingbracket.

3-1 Lineupthetabonthebottomofthebracketwiththegrooveonthemainmonitor(A).3-2 Lineupthetabonthetopofthebracketwiththegrooveonthemainmonitor,and

pushthemainmonitordownuntilitissecure(B).

Wall

1 Attachthemountingbrackettothewallsecurely.

● Install themountingbracketonaverticalflatwall.

ARemovescrewAandthenremovetheterminalcover.

B LoosenscrewBandpushinthewiresoftheDCcabletotheterminalconnectors(non-polar),thentightenthescrews.● Recommendedtorque:0.8N·m{8.2kgf·cm}

CUsethecablebinder(accessory)tosecuretheDCcable(double-coatedarea)tothemainmonitor.

D Makesuretoreplacetheterminalcover.

How to connect the DC cable:

Whilepressingonthebuttonwithapoint-edobjectsuchasascrewdriver,insertthewireintotheterminalconnector.(Todisconnectawire,whilepressingonthebutton,pulloutthewire.)

Barewireattip

9mm

Terminal Button

Wiringfromdoorphone

Important:Donotconnectthepowercable.(Damagemayoccur.)

How to make wiring connections:

Resetbutton

SDcardslot

20cm

20cm

20cm

20cm

Cablebinder(accessory)

12mm

Barewireattip ScrewB

● Forthefollowingreasons,leaveatleast20cmofspaceabove,below,andtotheleftandrightsidesofthemainmonitor:- Topreventmalfunctionandsoundcuttingout- ToensureSDcardscanbeinsertedandremoved,andtomakesuretheresetbuttoncanbeused(theSDcardslotisonthesideofthemainmonitor;theresetbuttonisonthebottom)

■ About the installation position of the main monitor and mounting bracket● Placethemainmonitorinalocationthatyoureyesarethesameheightasthecentreofthedisplay.

● Afterdecidingwheretoinstallthemainmonitor,attachthemountingbracket in the locationshownon theright.

Doorphone installation position Installing the power supply unit

Imagerange:Approx.900

Approx.500

Approx.85° Approx.170°

Centre (default)

Imagerange:Approx.900

Approx.85°

Right

Imagerange:Approx.900

Approx.500

Approx.170° Approx.85°

Approx.500

Approx.850

Approx.1,450

Approx.550

32mm

When set to wide (default)

Centreofdoorphone

Centreofdoorphone

Centreofdoorphone

Approx.95°

Centreofdoorphone

Approx.1,450 Approx.500

Approx.900Approx.170°

Approx.500

Approx.1,100

Approx.2,000

Imagerange

Imagedisplayedonmainmonitor:

Viewwhenlookingfromabove

Viewwhenlookingfromabove

(Units:mm)

Notes about electrical wiringMakesurenottopinchthewires(asshowntotheright)onthemountingbracketwheninstalling.● Donotforciblyattachtothemountingbracket.

Vertical,flatwall

Screws(locallyprocured)

Holeinwall

83.560

750

Mountingbracket

(Units:mm)

(Units:mm)

(Units:mm)

(Units:mm)