Installation Guide
Note to the installer■ Beforeattemptingtoconnectoroperatethisproduct,pleasereadthelabelontherearofthemainmonitor.
■ Pleasereadthisguidecarefully,andinstalltheproductsafelyandcorrectlybyfollowingtheinstructions.Carefullyreadtheinformationfoundinthesectiontitled"Foryoursafety"inparticular.
■ Onlyuseattachments/accessoriesspecifiedbythemanufacturer.■ Theinstallationshallbecarriedoutinaccordancewithallapplicableinstallationrules.■ Panasonicassumesnoresponsibilityforinjuriesorpropertydamageresultingfromfailuresarisingoutofimproperinstallationoroperationinconsistentwiththisguide.Additionally,anyresultingmalfunctionwillnotbecoveredunderthewarranty.
■ Afterinstallation,makesuretoleavethisguidewiththecustomer.
For the Installation of door station and main monitor station
•VL-V554EXisasurfacemounttype,VL-V554UEXisaflushmounttype.
For your safetyTopreventsevereinjuryandlossoflife/property,readthissectioncarefullybeforeusingtheproducttoensureproperandsafeoperationofyourproduct.
WARNINGPreventingfire,electricshockandshortcircuits● Leaveinstallationworktothedealer.Installationworkrequirestechniqueandexperiences.Failuretoobservethismaycausefire,electricshock,injury,ordamagetotheproduct.Consultthedealer.● Electricalconnectionworkshouldbeperformedbycertifiedpersonnelonly.Certificationisrequiredforperformingelectricalconnectionwork.Consultyourdealer.● Useonlythespecifiedpowersupplyunit.● Donotattempttodisassembleormodify thisproduct.Contactanauthorisedservicecentreforrepairs.● Neverinstallwiringduringalightningstorm.● Donotconnectnon-specifieddevices.● Donotconnectapowercabletoaterminalthatisnotspecifiedinthisguide.●Whenopeningholes inwalls for installationorwiring,orwhensecuring thepowercable,makesureyoudonotdamageexistingwiringandductwork.● Donotmakeanywiringconnectionswhenthepowersupplyisturnedon.● Donotusethesuppliedpowersupplyunitforoutdoorinstallations(itisforindooruseonly).● Donotinstallthemainmonitorandpowersupplyunitinthefollowingplaces:- Placeswherethemainmonitorandpowersupplyunitmaybesplashedwithwaterorchemicals.- Placeswherethereisahighconcentrationofdust,orhighhumidity.● Donotperformanyactions(suchasfabricating,twisting,stretching,bundling,forciblybending,damaging,altering,exposingtoheatsources,orplacingheavyobjectsonthepowercable) thatmaydamagethepowercable.Usingtheproductwithadamagedpowercablemaycauseelectricshock,shortcircuits,or fire.Contactanauthorisedservicecentreforrepairs.●Whenexistingchimewiresareused, it ispossible that theycontainACvoltage.Contactanauthorisedservicecentre.
● Donot installorusetheproduct inhealthcare facilities ifanyregulationsposted inthearea instructyounot todoso.Hospitalsorhealthcare facilitiesmaybeusingequipmentthatcouldbesensitivetoexternalRF(radiofrequency)energy.● Donot install oruse thisproductnearautomatically controlleddevicessuchasautomaticdoorsandfirealarms.Radiowavesemitted fromthisproductmaycausesuchdevicestomalfunction,resultinginanaccident.
Preventingaccidentsandinjuries
CAUTION
● Ifthewiringisunderground,donotmakeanyconnectionsunderground.● Ifthewiringisunderground,useaprotectiontube.● Ifthewiringisoutdoors,useaprotectiontubeorasurgeprotector.
● Install theproductsecurelyadhering to the instructions in thisguide toprevent it fromfallingoff thewall.Avoid installingonto low-strengthwalls,suchasgypsumboard,ALC(autoclavedlightweightconcrete),concreteblock,orveneer(lessthan18mmthick)walls.
Preventingelectricshock
Preventinginjury
1-62,4-chome,Minoshima,Hakata-ku,Fukuoka812-8531,Japan
©PanasonicSystemNetworksCo.,Ltd.2013PNQW3982ZA PC1113MT1113
VL-V554EX/VL-V554UEX
VL-MWD501EX
Doorstation Mainmonitorstation
Doorstationisdescribedas"doorphone"andMainmonitorstationisdescribedas"mainmonitor"inthisguide.
ModelNo. VL-SWD501EXVL-SWD501UEX
Wireless Video Intercom System
Toavoidmalfunctionorcommunicationdisturbances,donotinstallthedoorphoneorthemainmonitorinthefollowinglocations:- Placeswherevibrationoranyotherkindofimpactoccurs.- Placeswhereechoingisfrequent.- Placesnearahighconcentrationofdust,hydrogensulphide,ammonia,sulphur,ornoxiousfumes.
■ For the doorphone● Ifastronglightisshiningonthedoorphone,thevisitor’sfacemaynotbedistinguishable.Donotplacethedoorphoneinthefollowinglocations:- Wheremostofthebackgroundisthesky.- Wherethebackgroundisawhitewall,anddirectsunlightwillreflectoffit.- Wheredirectsunlightwillshineonthedoorphone.
● Donotplace thedoorphone in locationswhereechoingoccurs,as thiswill cause thedoorphonetobeepfrequently.● Dustprotection/waterprotectionisIP54.Onlywheninstallationworkspecifiedinthisguideisproperlyperformedandappropriatewaterprotectiontreatmentisperformed.●Makesuretherearofthedoorphoneisnotsubjecttowater.● Dependingontheinstallationlocation,condensationmayformonthedoorphone’slenscover.Thismaycauseimagestobecomeobscured.Condensationwilldissipateasthetemperaturerises.
■ For the main monitor● Install themainmonitoraway fromelectronicappliancessuchasTVs, radios,personalcomputers,airconditioners,boilercontrolpanelswith intercom,homesecurityequipment,wirelessdevices,ordigitalcordlessphones.● Donotinstallthemainmonitorinplaceswhereitwillbeaffectedbyextremelyhigh-frequencyradiowaves(nearbroadcastingantennasetc.).Thismaycausethedisplaytoflickeroraninterruptingnoisetooccur.● Leaveat least20cmofspaceabove,below,and to the leftand rightsidesof themainmonitor.Donotinstallonawallthatisdeeplyrecessed.● Donotinstallthemainmonitorinsideawall.● Besuretoinstallthemainmonitormorethan5mawayfromthedoorphone.● Theproduct operates in the frequency rangeof 1.88GHz to 1.90GHz, and theRFtransmissionpower is250mW(max.).Refer to the"Forbestperformance"section in theOperatingInstructions.● Inareassurroundedbyahighelectricalfield,disturbancesmayoccur inthemainmonitor’simageorsound.
Supplied accessories for installation■ For the doorphone
(EXonly)
Mountingbase×1
(UEXonly)
Flushmountingbox×1
Screw×4(Usedwheninstallingthedoorphone)(EX:4mmx12mm)(UEX:4mmx25mm)
Nameplate×2(incl.1spare) Hexwrench×1
■ For the main monitor
Mountingbracket×1
Cablebinder×1
■ Power supply unit and related items
Powersupplyunit×1
(PartNo.VL-PS240)Cablebinder×2
Important: ●You will need the following additional items to install and configure the doorphone and the main monitor. [Locally procured]- Screws(formountingbase:×2,formountingbracket:×2):Preparethescrews( thedrawingontheright)accordingtothematerial,structure,strengthandotherfactorsofthemountingareaandthetotalweightofobjectstobemounted.- Powercables(AC/DCcables),wires(fordoorphoneandotherconnections):Preparecablesandwiresoftheappropriatespecification.( "Wiretypeandlength")
Note:● Theillustrationsinthesuppliedmanual(s)mayvaryslightlyfromtheactualproduct.
4mm
Precautions for installation
Wiring schematic diagramSetupcorrectlyaccordingtothefollowingwiringschematicdiagramand"Wiretypeandlength".● Forinformation,suchasordernumbers,aboutoptionaldevicesthatcanbeconnectedto,refertothe"Additional/replacementaccessories"sectionintheOperatingInstructions.
MAIN MONITOR
DOORPHONE 1
DOORPHONE 2
POWER SUPPLY UNIT
220-240VAC
Connectiondeviceforoptionoutput(Acontact)
*1MakesuretoonlyconnectelectricvehiclegatelockstotheS3/S4terminalsofthedoorphones.
*2MakesuretoonlyconnectelectricdoorlockstotheS1/S2terminalsofthedoorphones.
NP: Non-polarised
Powersupply
Powersupply
Powersupply
Powersupply
12VAC/DC
12VAC/DC
12VAC/DC
12VAC/DC
Electriclock(Electricvehiclegatelock)*1
Electriclock(Electricdoorlock)*2
Electriclock(Electricdoorlock)*2
Electriclock(Electricvehiclegatelock)*1
24VDC
Wire type and length
WiringrunWiretype*1
Diameter Length(Max.)
Mainmonitor–Doorphone
A
φ0.65mm 22AWG 100m
φ1.0mm 18AWG 130m
φ0.5mm CAT5 50m
Mainmonitor–Powersupplyunit
Bφ0.65mm 22AWG 10m
φ1.0mm 18AWG 20m
Powersupplyunit–ACpowersource
C φ1.2mm-φ2.0mm(17AWG-12AWG) Norequirement
Doorphone–Electriclock*2
D φ0.5mm-φ1.2mm(24AWG-17AWG)
Accordingtospecifi-cationofconnected
device.
Mainmonitor–Connectiondeviceforoption
output(Acontact)*2E φ0.5mm-φ1.2mm
(24AWG-17AWG)
Accordingtospecifi-cationofconnected
device.
*1Type:Single-paircablewithoutersheath(jacket)Conductor:Coppersolid● Acertifiedpowersupplywiringhastobeusedwiththisequipment.Therelevantnationalinstallationand/orequipmentregulationsshallbeconsidered.AcertifiedpowersupplywiringnotlighterthanordinarypolyvinylchlorideflexiblewiringaccordingtoIEC60227shallbeused.
*2Whenusinganelectriclockoraconnectiondeviceforoptionoutput(Acontact),selectadevicethatmeetsthefollowingguidelines:● Electriclockconnectionterminal(S1/S2,S3/S4):- N/Odryclosurecontact- 12VAC/DC,lessthan1A
●Connectiondeviceforoptionoutput(Acontact)terminal(OUT1/OUT2):- 24VAC/DC,lessthan0.3A(minimumcontact:5VDC1mA)
A D
DE
B
C
NP
NPNP
NP
NP
NP
NP
NP
ScrewA
Youcanusethe[Wide/Zoomsettings]settingonthemainmonitortoselecttheareathatisvisiblewhenavisitorcalls;availablesettingsare[Wide],[Zoom],and[All](entireimagedisplay).(Defaultsetting:[Wide])
● Thefollowingvaluesareforwhenthedoorphoneisinstalledinthestandardposition(thecentreof thedoorphone’sheight isapproximately1,450mm)andatadistanceofapproximately500mmfromthecameralens.
■ Installation height and area visible by the camera lens
When set to zoom
Displaysaportionofthewideimageat2timesthesize.● Becauseadigital zoom isused, the imagequalityof zoomdisplayislowerthanthatofwidedisplayorentireimagedisplay.
Imagedisplayedonmainmonitor:
● Youcanusethemainmonitor’s [Zoompositionsettings]settingtoselect thedesiredareavisiblewhenzooming.Refertothefollowingandconfigurethemainmonitor.
Entire image display
Theareaaboveandbelowthewideimageisvisible.
Important:● Onthebottomsurfaceofthedoorphoneandthemountingbase,thereareholestoallowwatertodrain.Donotcoverthemupwheninstalling.●Whenexistingwiring(suchaschimewires)isused:- ItmaycontainACvoltagethatmaycauseelectricshockand/ordamagetheproduct.- Neverusethefollowingtypesofwiring.Consultaqualifiedtechnician/dealer.
VL-V554EX VL-V554UEX
1 Attachthemountingbasetothewallsecurely.
Mountingbase(accessory)
Wire(locallyprocured)
Wall
83.5mm
Screws(locallyprocured)×2
● Installthemountingbaseonaverticalflatwall.
1 Installtheflushmountingboxinthewall.
Flushmountingbox(accessory)
100mmKnockouthole*1
151mm
37mm
*1Onlyopentheknockoutholesasrequiredforthewiring.
2 Useahexwrench(accessory)toloosenscrewAandremovethefrontpanelofthedoor-phone.
ScrewA
Frontpanel
2mmhexwrench (accessory)
3 Connectthewires.
Terminalforthemainmonitor
<Rear view>
Terminalsfortheelectriclocks● Recommendedtorque:0.5N·m{5.1kgf·cm}●Maximumtorque:0.7N·m{7.1kgf·cm}
3-1Loosenthescrews.3-2Pushinthewirestotheterminalconnectors(non-polar),thentightenthescrews.
4 Attachthedoorphonetothemountingbase.
Screws(accessory)×4
4 Attachthedoorphonetotheflushmountingbox.
Screws(accessory)×4
5 AttachthenameplatetothedoorphoneandusescrewAtosecurethefrontpanel.●Writethenameonthenameplateasneeded.
Nameplate(accessory)
ScrewA ●Recommended torque:0.35N·m{3.6kgf·cm}
Approx.500
Approx.170°
Approx.2,250
Imagerange
Approx.115°
Approx.500
Imagedisplayedonmainmonitor:
Approx.1,600
Approx.650
Approx.1,450
Upanddown Leftandright(whenlookingfromabove)
Up ImagerangeApprox.2,050
Approx.500
Centreofdoorphone
Approx.45°
Centre (default)
Approx.45°
Approx.500
ImagerangeApprox.1,650
DownApprox.45°
Approx.500
Approx.1,400
Imagerange
Left
Approx.1,500Approx.1,450
Approx.550
Approx.1,450 Approx.1,250
Approx.400
Installing the doorphone■ About the installation location
● Thedevicemustbeinstalledinsideanelectricalpanelorcabinet.● Areadilyaccessibledisconnectdeviceshallbeincorporatedexternaltotheequipment.- Externaldisconnectdevicemustbecertifiedandhaveacreepageandclearancedistanceof3mmormore.
■ Precautions for wiring●Makesureyouturnoffthepoweratthebreakerbeforeperforminganywiringwork.● AlwaysconnectACorDCcables to theappropriateconnection terminals. IncorrectlyconnectingtheACorDCcablesmaydamagethepowersupplyunit.● Toprevent thepowercables fromdisconnectingandtopreventelectricshock,securethepowercablesusingthecablebinders(accessory)andattachthecablecovers.
How to connect the power cable (AC/DC)
1 StriptheAC/DCcablesasfollows:
7mm
45mm<ACcable>
<DCcable>25mm
7mm
2 Removethescrews(B)andthenremovethecablecovers(A).
3 ConnecttheAC/DCcabletotheACINterminal/DCOUTterminalonthetopandbottomofthepowersupplyunit,andthensecurethewiresbytighteningthescrews.
● Recommendedtorque:- ACterminal:0.4N·m{4.1kgf·cm}- DCterminal:0.45N·m{4.6kgf·cm}
<Frontview>ACcable*1
DCcable
Screws
*1
Cablebinders(accessory)
4 Usethecablebinders(accessory)tosecuretheAC/DCcables(double-coatedarea)tothepowersupplyunit.
5 Makesuretoreplacethecablecovers(A).
Connectthepowersupplyunit(accessory)andAC/DCcables(locallyprocured).
CAUTIONInsertthecablesfirmlyallthewayintotheterminals.Ifthecablesarenotinsertedalltheway,heatmaybegenerated.
*1Makesurethattherearenobarewiresexposedoutsidetheproduct.
Screws(B)Cablecovers(A)
DCOUTterminal
ACcablebinderhole
ACINterminal
<Topview>
<Bottomview>
DCcablebinderhole
Power supply unit (with cable covers removed)
Attach to the DIN rail
Attachintheorderdescribedbelowsothathook(b)ispositionedatthebottom.
1 Hanghook(a)ontheDINrail(A).
2 Pullandholdtheleverdown(B).
3 Securehook(b)totheDINrail(C).
Hook(a)
A
B
C
Hook(b)
Main monitor installation position
Installing the main monitor
Mainmonitorinstallationposition
82.5mm
82.7mm
2 ConnecttheDCcableandwires.
● Connect thewirescorrectlyaccording to"Wiringschematicdiagram".
3 Mountthemainmonitortothemountingbracket.
3-1 Lineupthetabonthebottomofthebracketwiththegrooveonthemainmonitor(A).3-2 Lineupthetabonthetopofthebracketwiththegrooveonthemainmonitor,and
pushthemainmonitordownuntilitissecure(B).
Wall
1 Attachthemountingbrackettothewallsecurely.
● Install themountingbracketonaverticalflatwall.
ARemovescrewAandthenremovetheterminalcover.
B LoosenscrewBandpushinthewiresoftheDCcabletotheterminalconnectors(non-polar),thentightenthescrews.● Recommendedtorque:0.8N·m{8.2kgf·cm}
CUsethecablebinder(accessory)tosecuretheDCcable(double-coatedarea)tothemainmonitor.
D Makesuretoreplacetheterminalcover.
How to connect the DC cable:
Whilepressingonthebuttonwithapoint-edobjectsuchasascrewdriver,insertthewireintotheterminalconnector.(Todisconnectawire,whilepressingonthebutton,pulloutthewire.)
Barewireattip
9mm
Terminal Button
Wiringfromdoorphone
Important:Donotconnectthepowercable.(Damagemayoccur.)
How to make wiring connections:
Resetbutton
SDcardslot
20cm
20cm
20cm
20cm
Cablebinder(accessory)
12mm
Barewireattip ScrewB
● Forthefollowingreasons,leaveatleast20cmofspaceabove,below,andtotheleftandrightsidesofthemainmonitor:- Topreventmalfunctionandsoundcuttingout- ToensureSDcardscanbeinsertedandremoved,andtomakesuretheresetbuttoncanbeused(theSDcardslotisonthesideofthemainmonitor;theresetbuttonisonthebottom)
■ About the installation position of the main monitor and mounting bracket● Placethemainmonitorinalocationthatyoureyesarethesameheightasthecentreofthedisplay.
● Afterdecidingwheretoinstallthemainmonitor,attachthemountingbracket in the locationshownon theright.
Doorphone installation position Installing the power supply unit
Imagerange:Approx.900
Approx.500
Approx.85° Approx.170°
Centre (default)
Imagerange:Approx.900
Approx.85°
Right
Imagerange:Approx.900
Approx.500
Approx.170° Approx.85°
Approx.500
Approx.850
Approx.1,450
Approx.550
32mm
When set to wide (default)
Centreofdoorphone
Centreofdoorphone
Centreofdoorphone
Approx.95°
Centreofdoorphone
Approx.1,450 Approx.500
Approx.900Approx.170°
Approx.500
Approx.1,100
Approx.2,000
Imagerange
Imagedisplayedonmainmonitor:
Viewwhenlookingfromabove
Viewwhenlookingfromabove
(Units:mm)
Notes about electrical wiringMakesurenottopinchthewires(asshowntotheright)onthemountingbracketwheninstalling.● Donotforciblyattachtothemountingbracket.
Vertical,flatwall
Screws(locallyprocured)
Holeinwall
83.560
750
Mountingbracket
(Units:mm)
(Units:mm)
(Units:mm)
(Units:mm)