Upload
thermosol5416
View
214
Download
0
Embed Size (px)
Citation preview
7/27/2019 Vitocell-B 100 TDM
1/12
VVVVIIIITTTTOOOOCCCCEEEELLLLLLLL 1111000 00 00 0- ---BBBB
Dual coil domestic hot water storage tank79 and 119 USG / 300 and 450 ltr
Technical Data ManualModel Nos. and pricing: see Price List
This tank version is not suitablefor steam heating applications
Vitocell 100-B
CVB Series
Vertical indirect-fired dual coil domestic hot water storage tankmade of steel with Ceraprotect enamel coating
7/27/2019 Vitocell-B 100 TDM
2/12
Product Information
Product InformationDomestic hot water storage tank of corrosionprotected steel with built-in insulation madeof PUR Foam.Fully hygienic, efficient and economicaldomestic hot water production by solarcollectors and a hot water heating boiler.Heat from the solar collectors is transferredto the domestic hot water via the lowertank coil.
Benefits at a glance:
H Corrosion-resistant tank with Ceraprotectenamel coating ensures a long service life .Additional cathode protection is providedby a magnesium anode.
H The entire water content is heated by acoiled 1/25 mm diameter steel heat
exchanger surface which extends to thebottom of the tank .
H Large heat exchanger surfaces allow fastand even heating of the entire watercontent, guaranteeing a high level ofdomestic hot water comfort.
H Increased energy savings thanks to highlyeffective, foamed-in-place HCFC-freeinsulation keeping standby losses at a
minimum.
H Two thermometers to show the DHWtemperature at the top of the tank and atthe midpoint of the tank.
H The Vitocell-B 100 119 USG / 450 Lcapacity tank is supplied with removablesoft PET insulation for easier handling.
H For dual-mode DHW heating with solarpanels in conjunction with a boiler. Thesolar energy gathered by the solar panelsis transferred to the DHW by the lowerindirect coil. For mono-mode DHW heatingwith a boiler or heat pump - both indirectcoils can be connected in series.
7/27/2019 Vitocell-B 100 TDM
3/12
7/27/2019 Vitocell-B 100 TDM
4/12
Technical Data
Technical Data
For DHW production in conjunction with heating boilers, Suitable for heating systems with:and heating systems without low limit for dual coil operation H max. working pressure on heat exchanger side up to 150 psig at
320F/160CH max. working pressure on DHW water side of up to 150 psig at
210F/99CH max. testing pressure on DHW side of 300 psig
Storage capacity USG / ltr 79 / 300 119 / 450
Coil upper *1 lower *2 upper *1 lower *2
Recovery rate *3
with a DHW temperature increase from 50 to 113 F/194F/90C
MBH / kWGPH / ltr/h
106 / 31201 / 761
181 / 53344 / 1302
160 / 47305 / 1154
239 / 70454 / 1720
10 to 45 C and a supply water temperature of . . . . . . 176F/80C MBH / kWGPH / ltr/h89 / 26
169 / 640151 / 44
286 / 1081136 / 40
259 / 982198 / 58
376 / 1425
158F/70CMBH / kWGPH / ltr/h
68 / 20129 / 491
113 / 33214 / 811
102 / 30195 / 737
153 / 45292 / 1106
140F/60CMBH / kWGPH / ltr/h
51 / 1597 / 368
79 / 23150 / 566
75 / 22143 / 540
109 / 32208 / 786
122F/50CMBH / kWGPH / ltr/h
38 / 1171 / 270
62 / 18117 / 442
55 / 16104 / 393
82 / 24156 / 589
Recovery rate *3
with a DHW temperature increase from 50 to 140 F/ 194F/90CMBH / kWGPH / ltr/h
79 / 23104 / 395
154 / 45205 / 774
123 / 36164 / 619
181 / 53241 / 911
10 to 60 C and a supply water temperature of ......176F/80C
MBH / kWGPH / ltr/h
68 / 2091 / 344
116 / 34154 / 584
102 / 30136 / 516
151 / 44200 / 756
158F/70CMBH / kWGPH / ltr/h
51 / 1568 / 258
79 / 23104 / 395
75 / 22100 / 378
113 / 33150 / 567
Insulation Hard PUR Foam Soft PET insulation
Standby losses *4 MBH/24 h 7.8 9.5
Overall dimensions with insulation *5
Overall width ( )
Overall depth
Overall height
Tilt height including insulation
Tilt height excluding insulation
inchesmminchesmminchesmminchesmminchesmm
25633
28705
68174670
1792--
33850
36918
771955
--
73 1 /81860
Weight
Tank with insulation
lbs
kg
352
160
452
205Heat exchanger coil liquid content USG
ltr1.6
62.610
2.39
3.312.5
Heat exchanger area ft. 2
m 29.70.9
16.11.5
151.4
20.51.9
Connections Coils (male thread)Domestic cold/hot water (male thread)R i l i ( l h d)
111
111
11
1
7/27/2019 Vitocell-B 100 TDM
5/12
Technical Data
LegendIO Inspection and cleanout openingD DrainBWR Boiler water return (upper coil)SCR Solar collector return (lower coil) or
boiler returnBWS Boiler water supply (upper coil)SCS Solar collector supply (lower coil) or
boiler supplyDCW Domestic cold waterSW1 *1 Sensor well for tank temperature
sensor of boiler control at BWSlevel
SW2 Sensor well for the lowerthermometer at SCS level
DHW Domestic hot waterRT Recirculation tappingTPV Temperature and pressure relief
valveMA Protective magnesium anode
*1 For solar heating systems Viessmannrecommends placement of the DHW tank temperature sensor of the solar control inthe solar collector return (SCR). Thisrequires a brass elbow with sensor well included in the accessory pack.The DHW tank temperature sensor of theboiler control is placed in the SW1 sensor well (see installation example on page 8).
Y
Total depth
T o t a l w i d t h
Section A-B
SW1
SW2
T o t a l h e i g h t
g
f e
d c
b a h
DHW
TH
MA
IO
TPV
BWS
RT
BWR
SCS
SCR
DCW/D
k
*1
*1
79 USG / 300 ltr Tank
DHW tank temperature sensorin solar heating applications79 USG / 300 ltr
DHW tank temperature sensor forsolar application (included withSolar control)Brass elbow with sensor well
Storagecapacity
USG /ltr
79 /300
a
b
c
d
e
f
g
h
inchesmminchesmminchesmminchesmminchesmminchesmminchesmminches
376
10260
34875
39995
43111553
135563
160013
7/27/2019 Vitocell-B 100 TDM
6/12
Technical Data
LegendIO Inspection and cleanout openingD DrainBWR Boiler water return (upper coil)SCR Solar collector return (lower coil) or
boiler returnBWS Boiler water supply (upper coil)SCS Solar collector supply (lower coil) or
boiler supplyDCW Domestic cold waterSW1 *1 Sensor well for tank temperature
sensor of boiler control at BWSlevel
SW2 Sensor well for the lowerthermometer at SCS level
DHW Domestic hot waterRT Recirculation tappingTPV Temperature and pressure relief
valveMA Protective magnesium anode
*1 For solar heating systems Viessmannrecommends placement of the DHW tank temperature sensor of the solar control inthe solar collector return (SCR). Thisrequires a brass elbow with sensor well included in the accessory pack.The DHW tank temperature sensor of theboiler control is placed in the SW1 sensor well (see installation example on page 8).
119 USG / 450 ltr Tank
SCR
SCS
DHW
RT
BWS
a
*1
BWR
d
Section A-B
SW1
SW2
MA
k h
DCW/D
c
e
b
f g
T o t a l h e i g h t
T o t a l w i d t h
Total depth
TH*1
C
DHW tank temperature sensorin solar heating applications119 USG / 450 ltr
DHW tank temperature sensor for solarapplication (included with solar controlunit)
Storagecapacity
USG /ltr
119 /450
a
b
c
d
e
f
g
h
inchesmminchesmminchesmminchesmminchesmminchesmminchesmminches
4 107
13349
36 3 /8924
411044
48 3 /81230
56 7 /8144470 1784
16 5 /
7/27/2019 Vitocell-B 100 TDM
7/12
7/27/2019 Vitocell-B 100 TDM
8/12
Standard Equipment/Product Installation
Standard Equipment
Vitocell 100-B (79 USG / 300 ltrcapacity) DHW TankDHW tank made from steel withCeraprotect enamel coating. 2 welded sensor wells for DHW tank
temperature sensor, i.e. aquastat, andthe thermometer
adjustable leveling bolts protective magnesium anode fitted thermal insulation made from
hard PUR foam threaded elbow with sensor wellThe color of the epoxy-coated sheetmetal casing is Vitosilver.
The following are packed separately andattached to the crate: 1 brass elbow with sensor well 1 Loctite package 1 temperature and pressure relief valve 2 thermometers F / C 7 brass adaptors (1) 1 brass tee (1) 1 brass hex bushing (1x) 1 brass cap (1)
Product Installation
Domestic hot water connection
Vitocell 100-B (119 USG / 450 ltrcapacity) DHW TankDHW tank made from steel withCeraprotect enamel coating. 2 welded sensor wells for DHW tank
temperature sensor, i.e. aquastat, andthe thermometer
protective magnesium anode fitted thermal insulation made from soft
PET insulation, packed separately threaded elbow with sensor well adjustable leveling bolts protective magnesium anodeThe color of the plastic-coated thermalinsulation is Vitosilver.
The following are packed separately andattached to the crate: 5 brass adaptors (1) 2 brass adaptors (1) 1 Loctite package
1 temperature and pressure relief valve 1 brass tee (1) 1 brass elbow with sensor well 1 brass cap 2 thermometers F / C 1 plug (R1)
Domestic hot water supplyDHW recirculation lineDHW recirculation pumpSpring-loaded flow check valveDischarge pipePressure and temperature relief valveShut-off valveDrainDomestic cold water supply linesBackflow preventer
Domestic cold water inletPrecharged expansion tank(required where backflow preventer isinstalled; check local plumbing codesand requirements)Thermostatic mixing valve/anti-scaldvalve for solar applications (fieldsupplied)
7/27/2019 Vitocell-B 100 TDM
9/12
7/27/2019 Vitocell-B 100 TDM
10/12
System Design Guidelines
Sensor wells
The sensor wells are welded into the DHWtank.
Sensor wells for solar operation
For solar heating systems, Viessmannrecommends placement of the DHW tanktemperature sensor in the solar collectorreturn. This requires installation of a a brasselbow with sensor well included in theaccessory pack.
Dimension 79/300 119/450
a
b
c
d
e
inchesmminchesmminchesmminchesmminchesmm
6 1/41605.9
1507/8
22
6.51 /3
8
8.72207.9
2107/8
22
6.51 /3
8
Heating water supply temperatureover 230F / 110C
These operating conditions require theinstallation of an additional safety high limitinto the DHW storage tank, preventing thedomestic hot water temperature from risingb 203 F/ 95 C A d i h
Temperature and pressurerelief valve
A temperature and pressure relief valve(T&P relief valve) is supplied with the tank.The heating contractor must install thevalve on each tank in a method meetingcode requirements. If local codes require adifferent relief valve, substitute themanufacturers supplied valve. The tank isapproved for 150 psig. Maximum operatingpressure is 150 psig.The T&P relief valve supplied with the tank
is tested under ANSI Z21.22 Code for ReliefValves and Automatic Gas Shut-off Devicesfor Hot Water Supply Systems.
Backflow preventers
Where backflow preventers are required, adomestic water expansion tank installationis recommended in the cold water inletpiping before the cold water enters theVitocell. For the backflow device, observelocal plumbing codes and regulations.
Watts Model40XL-8
150 psig(US and Canada)
ASME pressuresteam rating
1438 MBH
CSA temperaturesteam rating
205 MBH
Relieftemperature
210F (99C)
Inlet thread male
Outlet thread female
Warranty excerpt
Our warranty for domestic hot water tanksstates that the water to be heated must beof drinking (potable) water quality and thatany water treatment equipment in use mustfunction correctly.Viessmann accepts no responsibility fordamage howsoever caused and reserves theright to withdraw the product warranty if theproduct has been improperly installed ormisapplied by the installer, contractor or enduser. In order to qualify for product warranty,strict adherence to the installation andservice manuals must be assured. In theevent that Viessmann non-approvedcomponents are utilized, Viessmann reservesthe right to withdraw all expressed or impliedwarranties without written notice.
The water to be heated with the Vitocellmust be drinking (potable) water quality. Ifthe tank is used to heat other media, thewarranty will be null and void. Damageresulting from excessive pressure ortemperature is clearly not the responsibilityof Viessmann.
The amount of chloride and sulfateacceptable to the tank is limited. In areaswhere high concentrations of chloride andsulfate are present in drinking water, pleaseconsult Viessmann for directions.
For full warranty details, please read the
product warranty card.
8 / 200 mm
7 /8 / 2 1 m m
5 /8 / 16 mm
a
b
c
d e
7/27/2019 Vitocell-B 100 TDM
11/12
7/27/2019 Vitocell-B 100 TDM
12/12
1 2
VI T O CEL L 1 0 0- B
5285 656 v2.3 Printed on environmentally friendly(recycled and recyclable) paper.
Technical information subject to change without notice.