Virginia Endwalls

PCVAEW2018A

Page 2: Virginia Endwalls - Amazon S3€¦ · Endwalls Use Precast concrete endwalls are designed to anchor the pipe or box sections into the surrounding embankment, reduce hydraulic entrance

 

Endwalls 

 

Use 

Precast concrete endwalls are designed to anchor the pipe or box sections into the 

surrounding embankment, reduce hydraulic entrance and exit losses, and control erosion. 

 

Sizes 

Precast endwalls are normally available to accommodate all sizes and shapes of 

pipe. Please refer to the details that follow for specific sizes and dimensions. 

 

Application 

Precast concrete endwalls can be used for the following: 

● culverts beneath highways, railroads, or other embankments 

● storm drain or sewer outfalls 

● anywhere a pipe must conform to the slope of the surrounding terrain 

 

Joints 

Precast endwalls normally have no joints. 

 

 

Applicable Specifications 

Precast concrete endwalls can be produced to State or Local Department of 

Transportation requirements. 

Page 3: Virginia Endwalls - Amazon S3€¦ · Endwalls Use Precast concrete endwalls are designed to anchor the pipe or box sections into the surrounding embankment, reduce hydraulic entrance

TITLE

05-01-18

DATE

Precast Virginia Endwall(EW-1PC) for

12"Ø to 36"Ø Circular Pipe Culvert

Virginia Endwalls

20180605TED03

Elevation View

Isometric View

Side View

Notes

1) This design is intended for precast structures produced by CP&P only, not for cast-in-place

construction.

2) Concrete compressive strength 4,000 psi minimum.

3) Steel reinforcing design conforms to ASTM A706 or A615, grade 60 rebar or WWR

conforming to the requirements of ASTM A1064, grade 65 minimum.

4) Opening 8" maximum larger than pipe outside diameter. Additional reinforcement around

opening.

5) For use with pipe skewed 0° to 45°. Opening to be adjusted accordingly.

6) Contractor to consult VDOT EW-1PC standards for installation details.

7) All exposed 90° edges may be chamfered.

8) Length and reinforcement may be increased as necessary for handling considerations.

Pipe Size

H L

12'' 2'-3'' 4'-0''

15'' 2'-6'' 5'-0''

18'' 2'-8'' 6'-0''

21'' 3'-4'' 8'-0''

24'' 3'-4'' 8'-0''

27'' 4'-0'' 10'-0''

30'' 4'-0'' 10'-0''

33'' 4'-8'' 12'-0''

36'' 4'-8'' 12'-0''

8"

Pipe Opg

L

H

8"

2'-4"

14" 6"

(7)

Page 4: Virginia Endwalls - Amazon S3€¦ · Endwalls Use Precast concrete endwalls are designed to anchor the pipe or box sections into the surrounding embankment, reduce hydraulic entrance

TITLE

05-01-18

DATE

Precast Virginia Endwall(EW-1APC) for

23"x14" to 53"x34" Elliptical Pipe Culvert

Virginia Endwalls

20180605TED04

Elevation View

Isometric View

Side View

Notes

1) This design is intended for precast structures produced by CP&P only, not

for cast-in-place construction.

2) Concrete compressive strength 4,000 psi minimum.

3) Steel reinforcing design conforms to ASTM A706 or A615, grade 60 rebar

or WWR conforming to the requirements of ASTM A1064, grade 65

minimum.

4) Opening 8" maximum larger than pipe outside diameter. Additional

reinforcement around opening.

5) For use with pipe skewed 0° to 45°. Opening to be adjusted

accordingly.

6) Contractor to consult VDOT EW-1APC standards for installation details.

7) All exposed 90° edges may be chamfered.

8) Length and reinforcement may be increased as necessary for handling

considerations.

8"

Pipe Opg

L

H

(7)

2'-4"

14" 8" 6"

Approximate

Equivalent

Round Pipe

Size

Elliptical

Pipe Size

(Span x Rise)

H L

18" 23"x14" 2'-7" 5'-5"

24" 30"x19" 3'-0" 7'-2"

27" 34"x22" 3'-3" 8'-6"

30" 38"x24" 3'-6" 9'-2"

33" 42"x27" 3'-9" 10'-2"

36" 45"x29" 4'-0" 10'-11"

39" 49"x32" 4'-4" 12'-1"

42" 53"x34" 4'-6" 12'-11"

Page 5: Virginia Endwalls - Amazon S3€¦ · Endwalls Use Precast concrete endwalls are designed to anchor the pipe or box sections into the surrounding embankment, reduce hydraulic entrance

TITLE

05-07-18

DATE

Precast Virginia Endwall (EW-2PC) for

42"Ø to 96"Ø Circular Pipe Culvert

Virginia Endwalls

20180605TED10

Front Elevation View

Isometric View

Notes

1) This design is intended for precast structures produced by CP&P only, not

for cast-in-place construction.

2) Concrete compressive strength 4,000 psi minimum.

3) Steel reinforcing design conforms to ASTM A706 or A615, grade 60 rebar

or WWR conforming to the requirements of ASTM A1064, grade 65 minimum.

4) Opening 8" maximum larger than pipe outside diameter. Additional

reinforcement around opening.

5) For use with pipe skewed 0° to 15°. Opening to be adjusted accordingly.

6) Contractor to consult VDOT EW-2PC standards for installation details.

7) All exposed 90° edges may be chamfered.

8) Dimension "W" may be increased as necessary for handling considerations.

Plan View

Pipe Opg

H

4"

W

8"

6"

1

4

"

L

30°

(7)

L

3

4"Ø bolt, typ of 2 min each side @ 24"CC

6"

2

'

-

4

"

8"

Pipe

Size

H W

L

1

1

2

:1

Slope

L

2:1

Slope

42" 5'-8" 6'-6" 6'-8" 8'-8"

48" 6'-2" 7'-0" 7'-6" 9'-10"

54" 6'-8" 7'-8" 8'-5" 11'-0"

60" 7'-2" 8'-2" 9'-3" 12'-0"

66" 7'-10" 8'-10" 10'-0" 13'-4"

72" 8'-4" 9'-4" 11'-0" 14'-6"

78" 9'-0" 10'-0" 11'-10" 15'-8"

84" 9'-6" 10'-6" 12'-9" 16'-9"

90" 10'-2" 11'-2" 13'-8" 18'-0"

96" 10'-8" 11'-8" 14'-6" 19'-0"

Page 6: Virginia Endwalls - Amazon S3€¦ · Endwalls Use Precast concrete endwalls are designed to anchor the pipe or box sections into the surrounding embankment, reduce hydraulic entrance

TITLE

05-23-18

DATE

Precast Virginia Endwall (EW-2SPC) for

42"Ø to 96"Ø Pipe with 15° to 37.5° Skew

Virginia Endwalls

20180605TED11

Front Elevation View

Isometric View

Notes

1) This design is intended for precast structures produced by CP&P only, not for

cast-in-place construction.

2) Concrete compressive strength 4,000 psi minimum.

3) Steel reinforcing design conforms to ASTM A706 or A615, grade 60 rebar or

WWR conforming to the requirements of ASTM A1064, grade 65 minimum.

4) Opening 8" maximum larger than pipe outside diameter.

Additional reinforcement around opening.

5) For use with pipe skewed 15° to 37.5°. Left skew shown, right skew similar.

Opening to be adjusted accordingly.

6) Contractor to consult VDOT EW-2SPC standards for installation details.

7) All exposed 90° edges may be chamfered.

8) Dimension "W" may be increased as necessary for handling considerations.

Plan View

Pipe Opg

H

4"

W

8"

6"

(7)

3

4"Ø bolt, typ of 2 min each side @ 24"CC

15°Min

37.5°Max

30°

L

L

2

'

-

4

"

1

4

"

8"

6"

Pipe

Size

H W

L

1

1

2

:1

Slope

L

2:1

Slope

42" 5'-8" 8'-3" 6'-8" 8'-8"

48" 6'-2" 8'-11" 7'-6" 9'-10"

54" 6'-8" 9'-9" 8'-5" 11'-0"

60" 7'-2" 10'-6" 9'-3" 12'-0"

66" 7'-10" 11'-6" 10'-0" 13'-4"

72" 8'-4" 12'-4" 11'-0" 14'-6"

78" 9'-0" 13'-0" 11'-10" 15'-8"

84" 9'-6" 13'-10" 12'-9" 16'-9"

90" 10'-2" 14'-10" 13'-8" 18'-0"

96" 10'-8" 15'-10" 14'-6" 19'-0"

Page 7: Virginia Endwalls - Amazon S3€¦ · Endwalls Use Precast concrete endwalls are designed to anchor the pipe or box sections into the surrounding embankment, reduce hydraulic entrance

TITLE

05-07-18

DATE

Precast Virginia Endwall (EW-2SPC) for

42"Ø to 96"Ø Pipe with 37.5° to 45° Skew

Virginia Endwalls

20180605TED15

Front Elevation View

Isometric View

Notes

1) This design is intended for precast structures produced by CP&P

only, not for cast-in-place construction.

2) Concrete compressive strength 4,000 psi minimum.

3) Steel reinforcing design conforms to ASTM A706 or A615, grade

60 rebar or WWR conforming to the requirements of ASTM

A1064, grade 65 minimum.

4) Opening 8" maximum larger than pipe outside diameter.

Additional reinforcement around opening.

5) For use with pipe skewed 37.5° to 45°. Left skew shown, right

skew similar. Opening to be adjusted accordingly.

6) Contractor to consult VDOT EW-2SPC standards for installation

details.

7) All exposed 90° edges may be chamfered.

8) Dimension "W" may be increased as necessary for handling

considerations.

Plan View

Pipe Opg

H

4"

W

8"

6"

3

4"Ø bolt, typ of 2 min each side @ 24"CC

L45°

6"

8"

1

4

"

2

'

-

4

"

L30°

(7)

Pipe

Size

H W

L30°

1

1

2

:1

Slope

L30°

2:1

Slope

L45°

1

1

2

:1

Slope

L45°

2:1

Slope

42" 5'-8" 9'-2" 6'-8" 8'-8" 8'-3" 10'-8"

48" 6'-2" 9'-11" 7'-6" 9'-10" 9'-3" 12'-0"

54" 6'-8" 10'-10" 8'-5" 11'-0" 10'-3" 13'-6"

60" 7'-2" 11'-6" 9'-3" 12'-0" 11'-4" 14'-11"

66" 7'-10" 12'-6" 10'-0" 13'-4" 12'-5" 16'-4"

72" 8'-4" 13'-2" 11'-0" 14'-6" 13'-6" 17'-8"

78" 9'-0" 14'-1" 11'-10" 15'-8" 14'-6" 19'-0"

84" 9'-6" 14'-10" 12'-9" 16'-9" 15'-6" 20'-6"

90" 10'-2" 15'-9" 13'-8" 18'-0" 16'-8" 22'-0"

96" 10'-8" 16'-6" 14'-6" 19'-0" 17'-8" 23'-4"

30°

45°

37.5°Min

45°Max

Page 8: Virginia Endwalls - Amazon S3€¦ · Endwalls Use Precast concrete endwalls are designed to anchor the pipe or box sections into the surrounding embankment, reduce hydraulic entrance

TITLE

05-07-18

DATE

Precast Virginia Endwall (EW-2APC) for

60"x38" to 106"x68" Elliptical Pipe Culvert

Virginia Endwalls

20180605TED09

Front Elevation View

Isometric View

Notes

1) This design is intended for precast structures produced by CP&P

only, not for cast-in-place construction.

2) Concrete compressive strength 4,000 psi minimum.

3) Steel reinforcing design conforms to ASTM A706 or A615,

grade 60 rebar or WWR conforming to the requirements

of ASTM A1064, grade 65 minimum.

4) Opening 8" maximum larger than pipe outside diameter.

Additional reinforcement around opening.

5) For use with pipe skewed 0° to 15°. Opening to be adjusted

accordingly.

6) Contractor to consult VDOT EW-2APC standards for installation

details.

7) All exposed 90° edges may be chamfered.

8) Dimension W may be increased as necessary for handling

considerations.

Plan View

Pipe Opg

H

4"

W

8"

6"

(7)

3

4"Ø bolt, typ of 2 min each side @ 24"CC

L

L

30°

2

'

-

4

"

1

4

"

8"

6"

Approximate

Equivalent

Round Pipe

Size

Elliptical

Pipe Size

(Span x Rise)

H W

L

1

1

2

:1

Slope

L

2:1

Slope

48" 60"x38" 5'-8" 8'-3" 6'-8" 8'-8"

54" 68"x43" 5'-8" 9'-0" 6'-8" 8'-8"

60" 76"x48" 6'-2" 9'-9" 7'-6" 9'-10"

66" 83"x53" 6'-8" 10'-5" 8'-5" 11'-0"

72" 91"x58" 7'-2" 11'-2" 9'-3" 12'-0"

78" 98"x63" 7'-10" 11'-10" 10'-0" 13'-4"

84" 106"x68" 8'-4" 12'-7" 11'-0" 14'-6"

Page 9: Virginia Endwalls - Amazon S3€¦ · Endwalls Use Precast concrete endwalls are designed to anchor the pipe or box sections into the surrounding embankment, reduce hydraulic entrance

TITLE

05-02-18

DATE

Precast Virginia Endwall for Multiple(EW-6PC)

12"Ø to 36"Ø Circular Pipe Culvert

Virginia Endwalls

20180605TED05

Elevation View

Isometric View

Notes

1) This design is intended for precast structures produced by CP&P only, not for

cast-in-place construction.

2) Concrete compressive strength 4,000 psi minimum.

3) Steel reinforcing design conforms to ASTM A706 or A615, grade 60 rebar or WWR

conforming to the requirements of ASTM A1064, grade 65 minimum.

4) Opening 8" maximum larger than pipe outside diameter. Additional reinforcement

around opening.

5) For use with pipe skewed 0° to 15°. Opening to be adjusted accordingly.

6) Contractor to consult VDOT EW-6PC standards for installation details.

7) All exposed 90° edges may be chamfered.

8) Length and reinforcement may be increased as necessary for handling considerations.

9) Dimension "L" increased by dimension "S" for each additional pipe.

Side View

Pipe Size

H L S G

12'' 2'-3'' 5'-10'' 2'-0'' 1'-11"

15'' 2'-6'' 7'-3'' 2'-3'' 2'-6''

18'' 2'-8'' 8'-8'' 2'-8'' 3'-0''

21'' 3'-4'' 11'-6'' 3'-6'' 4'-0''

24'' 3'-4'' 11'-6'' 3'-6'' 4'-0''

27'' 4'-0'' 14'-4'' 4'-4'' 5'-0''

30'' 4'-0'' 14'-4'' 4'-4'' 5'-0''

33'' 4'-8'' 17'-2'' 5'-2'' 6'-0''

36'' 4'-8'' 17'-2'' 5'-2'' 6'-0''

Pipe Opg

L

H

8"

2'-4"

14"

8"

(7)

G S G

Pipe Opg

6"

Page 10: Virginia Endwalls - Amazon S3€¦ · Endwalls Use Precast concrete endwalls are designed to anchor the pipe or box sections into the surrounding embankment, reduce hydraulic entrance

TITLE

05-02-18

DATE

Precast Virginia Endwall for Multiple(EW-6SPC)

12"Ø to 36"Ø Circular Pipe Culvert with 30° or 45° Skew

Virginia Endwalls

20180605TED06

Elevation View

Isometric View

Notes

1) This design is intended for precast structures produced

by CP&P only, not for cast-in-place construction.

2) Concrete compressive strength 4,000 psi minimum.

3) Steel reinforcing design conforms to ASTM A706

or A615, grade 60 rebar or WWR conforming to the

requirements of ASTM A1064, grade 65 minimum.

4) Opening 8" maximum larger than pipe outside

diameter. Additional reinforcement around

opening.

5) Endwall with 30° skew for use with pipe

skewed 15° to 37.5°. Endwall with 45° skew

for use with pipe skewed 37.5° to 45°.

Openings to be adjusted accordingly.

6) Contractor to consult VDOT EW-6SPC standards

for installation details.

7) All exposed 90° edges may be chamfered.

8) Length and reinforcement may be increased as

necessary for handling considerations.

9) Dimension "L30° or L45°" increased by

dimension "S30° or S45°" for each additional

pipe.

Side View

Plan View

Pipe Size

H L30° L45° S S30° S45° G

12'' 2'-3'' 6'-3

3

8

" 6'-10'' 2'-0'' 2'-3

3

4

" 2'-10" 2'-0''

15'' 2'-6'' 7'-7

1

8

" 8'-2

1

8

" 2'-3'' 2'-7

1

8

" 3'-2

1

8

" 2'-6''

18'' 2'-8'' 9'-1" 9'-9

1

4

" 2'-8'' 3'-1'' 3'-9

1

4

" 3'-0''

21'' 3'-4'' 12'-0

1

2

" 12'-11

3

8

" 3'-6'' 4'-0

1

2

" 4'-11

3

8

" 4'-0''

24'' 3'-4'' 12'-0

1

2

" 12'-11

3

8

" 3'-6'' 4'-0

1

2

" 4'-11

3

8

" 4'-0''

27'' 4'-0'' 15'-0'' 16'-1

1

2

" 4'-4'' 5'-0" 6'-1

1

2

" 5'-0''

30'' 4'-0'' 15'-0'' 16'-1

1

2

" 4'-4'' 5'-0" 6'-1

1

2

" 5'-0''

33'' 4'-8'' 17'-11

5

8

" 19'-3

5

8

" 5'-2'' 5'-11

5

8

" 7'-3

5

8

" 6'-0''

36'' 4'-8'' 17'-11

5

8

" 19'-3

5

8

" 5'-2'' 5'-11

5

8

" 7'-3

5

8

" 6'-0''

Pipe

Opg

Pipe

Opg

S30° or S45°G G

H

8"

(7)

2'-4"

6"

14"

8"

L30° or L45°

S

30° or 45°

Page 11: Virginia Endwalls - Amazon S3€¦ · Endwalls Use Precast concrete endwalls are designed to anchor the pipe or box sections into the surrounding embankment, reduce hydraulic entrance

TITLE

05-23-18

DATE

Precast Virginia Endwall for Multiple(EW-7PC)

42"Ø to 96"Ø Circular Pipe Culvert

Virginia Endwalls

20180605TED12

Front Elevation View

Isometric View

Notes

1) This design is intended for precast structures produced by CP&P

only, not for cast-in-place construction.

2) Concrete compressive strength 4,000 psi minimum.

3) Steel reinforcing design conforms to ASTM A706 or A615, grade 60

rebar or WWR conforming to the requirements of ASTM A1064, grade

65 minimum.

4) Opening 8" maximum larger than pipe outside diameter. Additional

reinforcement around opening.

5) For use with pipe skewed 0° to 15°. Opening to be adjusted accordingly.

6) Contractor to consult VDOT EW-7PC standards for installation details.

7) All exposed 90° edges may be chamfered.

8) Dimension "T" may be increased by dimenion "S" for each additional

pipe and as necessary for handling considerations.

Plan View

Pipe Opg

H

4"

T

8"

6"

(7)

3

4"Ø bolt, typ of 2 min each side @ 24"CC

S

L

2

'

-

4

"

1

4

'

8"

6"

L

Pipe Opg

30°

Pipe

Size

H T S

L

1

1

2

:1

Slope

L

2:1

Slope

42" 5'-8" 12'-6" 6'-0" 6'-8" 8'-8"

48" 6'-2" 13'-10" 6'-10" 7'-6" 9'-10"

54" 6'-8" 15'-4" 7'-8" 8'-5" 11'-0"

60" 7'-2" 16'-8" 8'-6" 9'-3" 12'-0"

66" 7'-10" 18'-2" 9'-4" 10'-0" 13'-4"

72" 8'-4" 19'-6" 10'-2" 11'-0" 14'-6"

78" 9'-0" 21'-0" 11'-0" 11'-10" 15'-8"

84" 9'-6" 22'-4" 11'-10" 12'-9" 16'-9"

90" 10'-2" 23'-10" 12'-8" 13'-8" 18'-0"

96" 10'-8" 25'-2" 13'-6" 14'-6" 19'-0"

Page 12: Virginia Endwalls - Amazon S3€¦ · Endwalls Use Precast concrete endwalls are designed to anchor the pipe or box sections into the surrounding embankment, reduce hydraulic entrance

TITLE

05-28-18

DATE

Precast Virginia Endwall for Multiple(EW-7SPC)

42"Ø to 96"Ø Pipe with 15° to 37.5° Skew

Virginia Endwalls

20180605TED13

Front Elevation View

Isometric View

Notes

1) This design is intended for precast structures produced by CP&P

only, not for cast-in-place construction.

2) Concrete compressive strength 4,000 psi minimum.

3) Steel reinforcing design conforms to ASTM A706 or A615, grade

60 rebar or WWR conforming to the requirements of ASTM

A1064, grade 65 minimum.

4) Opening 8" maximum larger than pipe outside diameter.

Additional reinforcement around opening.

5) For use with pipe skewed 15° to 37.5°. Left kew shown, right

skew similar. Opening to be adjusted accordingly.

6) Contractor to consult VDOT EW-7SPC standards for installation

details.

7) All exposed 90° edges may be chamfered.

8) Dimension "T" may be increased by dimension S30° for each

additional pipe and as necessary for handling considerations.

Plan View

H

4"

T

8"

6"

S30°

3

4"Ø bolt, typ of 2 min each side @ 24"CC

(7)

30°

15°Min

37.5°Max

S

L

2

'

-

4

"

8"

6"

L

14"

Pipe

Size

H T S S 30°

L

1

1

2

:1

Slope

L

2:1

Slope

42" 5'-8" 16'-6" 6'-0" 7'-0" 6'-8" 8'-8"

48" 6'-2" 18'-4" 6'-10" 7'-11" 7'-6" 9'-10"

54" 6'-8" 20'-3" 7'-8" 8'-11" 8'-5" 11'-0"

60" 7'-2" 22'-2" 8'-6" 9'-10" 9'-3" 12'-0"

66" 7'-10" 24'-0" 9'-4" 10'-10" 10'-0" 13'-4"

72" 8'-4" 25'-11" 10'-2" 11'-9" 11'-0" 14'-6"

78" 9'-0" 27'-10" 11'-0" 12'-9" 11'-10" 15'-8"

84" 9'-6" 29'-8" 11'-10" 13'-8" 12'-9" 16'-9"

90" 10'-2" 31'-8" 12'-8" 14'-8" 13'-8" 18'-0"

96" 10'-8" 33'-8" 13'-6" 15'-8" 14'-6" 19'-0"

Pipe

Opg

Pipe

Opg

Page 13: Virginia Endwalls - Amazon S3€¦ · Endwalls Use Precast concrete endwalls are designed to anchor the pipe or box sections into the surrounding embankment, reduce hydraulic entrance

TITLE

05-30-18

DATE

Precast Virginia Endwall for Multiple(EW-7SPC)

42"Ø to 96"Ø Pipe with 37.5° to 45° Skew

Virginia Endwalls

20180605TED14

Front Elevation View

Isometric View

Notes

1) This design is intended for precast structures produced

by CP&P only, not for cast-in-place construction.

2) Concrete compressive strength 4,000 psi minimum.

3) Steel reinforcing design conforms to ASTM A706

or A615, grade 60 rebar or WWR conforming to the

requirements of ASTM A1064, grade 65 minimum.

4) Opening 8" maximum larger than pipe outside

diameter. Additional reinforcement around opening.

5) For use with pipe skewed 37.5° to 45°. Left skew

shown, right skew similar. Opening to be adjusted

accordingly.

6) Contractor to consult VDOT EW-7SPC standards for

installation details.

7) All exposed 90° edges may be chamfered.

8) Dimension "T" may be increased by dimension S45°

for each additional pipe and as necessary for

handling considerations.

Plan View

Pipe

Opg

H

4"

6"

Pipe

Opg

(7)

45°

S

T

S45°

8"

L30°

L45°

2'-4"

14"

8"

6"

30°

37.5°Min

45°Max

3

4"Ø bolt, typ of 2 min each side @ 24"CC

Pipe

Size

H T S S45°

L30°

1

1

2

:1

Slope

L30°

2:1

Slope

L45°

1

1

2

:1

Slope

L45°

2:1

Slope

42" 5'-8" 17'-8" 6'-0" 8'-6" 6'-8" 8'-8" 8'-3" 10'-8"

48" 6'-2" 19'-7" 6'-10" 9'-8" 7'-6" 9'-10" 9'-3" 12'-0"

54" 6'-8" 21'-9" 7'-8" 10'-11" 8'-5" 11'-0" 10'-3" 13'-6"

60" 7'-2" 23'-7" 8'-6" 12'-1" 9'-3" 12'-0" 11'-4" 14'-11"

66" 7'-10" 25'-9" 9'-4" 13'-3" 10'-0" 13'-4" 12'-5" 16'-4"

72" 8'-4" 27'-7" 10'-2" 14'-5" 11'-0" 14'-6" 13'-6" 17'-8"

78" 9'-0" 29'-8" 11'-0" 15'-7" 11'-10" 15'-8" 14'-6" 19'-0"

84" 9'-6" 31'-7" 11'-10" 16'-9" 12'-9" 16'-9" 15'-6" 20'-6"

90" 10'-2" 33'-8" 12'-8" 17'-11" 13'-8" 18'-0" 16'-8" 22'-0"

96" 10'-8" 35'-8" 13'-6" 19'-2" 14'-6" 19'-0" 17'-8" 23'-4"

Page 14: Virginia Endwalls - Amazon S3€¦ · Endwalls Use Precast concrete endwalls are designed to anchor the pipe or box sections into the surrounding embankment, reduce hydraulic entrance

TITLE

05-03-18

DATE

Precast Virginia Endwall(EW-9PC) for

Corrugated Metal Arch Pipe Culvert

Virginia Endwalls

20180605TED07

Elevation View

Isometric View

Side View

Notes

1) This design is intended for precast structures produced by CP&P only,

not for cast-in-place construction.

2) Concrete compressive strength 4,000 psi minimum.

3) Steel reinforcing design conforms to ASTM A706 or A615, grade 60

rebar or WWR conforming to the requirements of ASTM A1064,

grade 65 minimum.

4) Opening 8" maximum larger than pipe outside diameter. Additional

reinforcement around opening.

5) For use with pipe skewed 0° to 45°. Opening to be adjusted

accordingly.

6) Contractor to consult VDOT EW-9PC standards for installation details.

7) All exposed 90° edges may be chamfered.

8) Length and reinforcement may be increased as necessary for handling

considerations.

8"

Pipe Opg

L

H

(7)

2'-4"

14" 8" 6"

Approximate

Equivalent Round

Pipe Size

Arch

Pipe Size

(Span x Rise)

H L

2

2

3

" x

1

2

"

Corrugation

15" 17"x13" 2'-1" 4'-0"

18" 21"x15" 2'-3" 5'-0"

21" 24"x18" 2'-6" 6'-0"

24" 28"x20" 2'-8" 7'-0"

30" 35"x24" 3'-0" 8'-0"

36" 42"x29" 3'-8" 10'-0"

42" 49"x33" 4'-1" 12'-0"

48" 57"x38" 4'-6" 13'-0"

3" x 1" and 5" x 1"

Corrugation

36" 40"x31" 3'-8" 10'-0"

42" 46"x36" 4'-1" 12'-0"

48" 53"x41" 4'-6" 13'-0"

Page 15: Virginia Endwalls - Amazon S3€¦ · Endwalls Use Precast concrete endwalls are designed to anchor the pipe or box sections into the surrounding embankment, reduce hydraulic entrance

TITLE

05-03-18

DATE

Precast Virginia Endwall(EW-10PC) for

Multiple Corrugated Metal Arch Pipe Culvert

Virginia Endwalls

20180605TED08

Elevation View

Isometric View

Side View

Notes

1) This design is intended for precast structures produced by

CP&P only, not for cast-in-place construction.

2) Concrete compressive strength 4,000 psi minimum.

3) Steel reinforcing design conforms to ASTM A706 or A615,

grade 60 rebar or WWR conforming to the requirements of

ASTM A1064, grade 65 minimum.

4) Opening 8" maximum larger than pipe outside diameter.

Additional reinforcement around opening.

5) For use with pipe skewed 0° to 15°. Opening to be

adjusted accordingly.

6) Contractor to consult VDOT EW-10PC standards for

installation details.

7) All exposed 90° edges may be chamfered.

8) Length may be increased by dimension "M" for additional

pipes or as necessary for handling considerations.

8"

Pipe Opg

L

H

(7)

Pipe Opg

2'-4"

14" 6"

8"

G M G

Approximate

Equivalent

Round Pipe Size

Arch Pipe Size

(Span x Rise)

H L G M

2

2

3

" x

1

2

"

Corrugation

15" 17"x13" 2'-1" 6'-6" 2'-0" 2'-6"

18" 21"x15" 2'-3" 7'-10" 2'-6" 2'-10"

21" 24"x18" 2'-6" 9'-1" 3'-0" 3'-1"

24" 28"x20" 2'-8" 10'-5" 3'-6" 3'-5"

30" 35"x24" 3'-0" 12'-0" 4'-0" 4'-0"

36" 42"x29" 3'-8" 14'-10" 5'-0" 4'-10"

42" 49"x33" 4'-1" 17'-7" 6'-0" 5'-7"

48" 57"x38" 4'-6" 19'-6" 6'-6" 6'-6"

3" x 1" & 5" x 1"

Corrugation

36" 40"x31" 3'-8" 14'-10" 5'-0" 4'-10"

42" 46"x36" 4'-1" 17'-7" 6'-0" 5'-7"

48" 53"x41" 4'-6" 19'-6" 6'-6" 6'-6"

Page 16: Virginia Endwalls - Amazon S3€¦ · Endwalls Use Precast concrete endwalls are designed to anchor the pipe or box sections into the surrounding embankment, reduce hydraulic entrance

A A

TITLE

06-13-18

DATE

Precast Virginia Endwall EW-11

Virginia Endwalls

20180613TED01

Section View A-A

Isometric View

Side View

Notes

1) This design is intended for precast structures produced by CP&P only.

2) Concrete compressive strength 4,000 psi minimum.

3) Bar reinforcement design conforms to ASTM A706 or A615, grade 60 rebar or WWR

reinforcement conforms to ASTM A1064, grade 65 minimum.

4) Lift holes (if applicable) to be filled with an approved non-shrink grout.

5) Grate pipe and related hardware to be galvanized. See Drawing: Grate Pipe Assembly Detail.

6) Annular space between pipe and hole and on top of pipe support bracket block-out in wall (where

required) to be filled per VDOT specifications.

7) When pipe is installed at inlet end of culvert, bevel to be provided by others. Refer to VDOT road

and bridge standards for bevel details.

8) All exposed 90° edges may be chamfered.

9) Grates in accordance with VDOT EW-11.

10) *Extension at manufacturer's option. Adjust overall dimensions when extension is excluded.

11) **Pipe and support bracket related dimensions only.

12) See table drawing for dimensions.

Elevation View

Plan View

Notes

1) This design is intended for precast structures produced by CP&P only, not for cast-in-place

construction.

2) Concrete compressive strength 4,000 psi minimum.

3) Steel reinforcing design conforms to ASTM A706 or A615, grade 60 rebar or WWR

conforming to the requirements of ASTM A1064, grade 65 minimum.

4) Opening 8" maximum larger than pipe outside diameter. Additional reinforcement around

opening.

5) For use with pipe skewed 0° to 45°. Opening to be adjusted accordingly.

6) Contractor to consult VDOT EW-1PC standards for installation details.

7) All exposed 90° edges may be chamfered.

8) Length and reinforcement may be increased as necessary for handling considerations.

Slope Pipe Size

3:1 12'' to 60"

4:1 12" to 60''

6:1 12'' to 48"

L+22

1

2

"

L 8"12"

W+21"

(*)

W+16"W

Hole Opg

Centered

12"

Hole Opg

H

(Inside)

a

b

(8)

Curtain Wall

7

1

2

" Y

X

6"

Center Support

As Required

One Piece Wall

(5)

Weep Holes(Typ)

Keyway Joint

2

1

2

"(*)

8"

3" Ø Weep Holes

@ 8'-0" OC(Typ)

5

1

2

"

2

3

4

"

L3**

L2**

L4**

L5**

8

1

2

"

4

1

4

"

8

1

2

"

1" Ø Coil Insert

at Bottom

of Blockout(Typ)

Grate Pipe Pocket

OD +

1

4

"(Typ)

12" + Pipe OD

Between Grate

Pipes(Typ)

W

+

2

1

"

6

"

1

8

"

2"

Grate Pipe Pocket

Number of Grate Pipes Varies

Page 17: Virginia Endwalls - Amazon S3€¦ · Endwalls Use Precast concrete endwalls are designed to anchor the pipe or box sections into the surrounding embankment, reduce hydraulic entrance

TITLE

06-13-18

DATE

Precast Virginia Endwall EW-11

Grate Pipe Assembly Detail

Virginia Endwalls

20180613TED02

Section View A-A

Isometric View

Side View

Notes

1) This design is intended for precast structures produced by CP&P only.

2) Grate pipe and steel plate conforms to ASTM A36.

3) See table page for dimensions.

Elevation View

Elevation View

(Grate Pipe)

Notes

1) This design is intended for precast structures produced by CP&P only, not for cast-in-place

construction.

2) Concrete compressive strength 4,000 psi minimum.

3) Steel reinforcing design conforms to ASTM A706 or A615, grade 60 rebar or WWR

conforming to the requirements of ASTM A1064, grade 65 minimum.

4) Opening 8" maximum larger than pipe outside diameter. Additional reinforcement around

opening.

5) For use with pipe skewed 0° to 45°. Opening to be adjusted accordingly.

6) Contractor to consult VDOT EW-1PC standards for installation details.

7) All exposed 90° edges may be chamfered.

8) Length and reinforcement may be increased as necessary for handling considerations.

Elevation View

(Center Support Assembly)

Plan View

(4" x

1

2" Plate)

Isometric View

(Curtain Wall)

End View

(Grate Pipe)

Side View

(Center Support Assembly)

Pipe Size

L H A

12'' 11'-6'' 2'-3'' 10'-7

1

2

"

15'' 14'-10'' 2'-7'' 14'-0"

18'' 17'-4'' 2'-10'' 16'-6"

21'' 22'-4'' 3'-4'' 21'-6

1

2

"

24'' 22'-4'' 3'-4'' 21'-6

1

2

"

1

8

"

6

"

W

+

2

1

"

W+10"

W-2"

1/4"

8"

1/4" 8"

(Typ)

4"

L2

4"

2"L4

2"

4

1

4

"(Typ)

5

8

" Ø Hole for

Expansion Bolts(Typ)

8"

4"

2

1

4

"

2"

4"

4"

4

1

2

"

5"

16

1

2

"

1

4

" R

8"x4"x

1

4

"

Structural Tubing

2" 1

1

2

"Ø Hole for

1"Ø x9

1

2

" Coil Bolt

with Washer(Typ)

(2)

3

4

" Ø Holes Straight Thru when

Center Support is Required

Grate Pipe

Grate Pipe

Upper End

Shall be Capped

8"x4

1

2

" x

3

8

"

Steel Plate

3

4

"Ø Hole for

5

8

"Ø x 6

3

4

" Long Bolts

with (2) Flat Washers

& (1) Self Locking Nut

with Washer(Typ)

Varies

Center Between

Pipes Length Varies(Typ)

Page 18: Virginia Endwalls - Amazon S3€¦ · Endwalls Use Precast concrete endwalls are designed to anchor the pipe or box sections into the surrounding embankment, reduce hydraulic entrance

TITLE

06-13-18

DATE

Precast Virginia Endwall EW-11

Dimension Tables

Virginia Endwalls

20180613TED03

Notes

1) This design is intended for precast structures produced by CP&P only.

2) * Dimension may be reduced for specific pipe wall thickness.

Notes

1) This design is intended for precast structures produced by CP&P only, not for cast-in-place

construction.

2) Concrete compressive strength 4,000 psi minimum.

3) Steel reinforcing design conforms to ASTM A706 or A615, grade 60 rebar or WWR

conforming to the requirements of ASTM A1064, grade 65 minimum.

4) Opening 8" maximum larger than pipe outside diameter. Additional reinforcement around

opening.

5) For use with pipe skewed 0° to 45°. Opening to be adjusted accordingly.

6) Contractor to consult VDOT EW-1PC standards for installation details.

7) All exposed 90° edges may be chamfered.

8) Length and reinforcement may be increased as necessary for handling considerations.

6:1 Slope

Pipe Size

H L W

Grate Pipe Ø#Grate Pipes

L2 L3 L4 L5

12" 1'-10" 11'-0" 2'-0" 3

1

2

" 1 12'-1

3

4

"

N/A N/A N/A

15" / 18"2'-4

1

2

" 14'-3" 2'-0" 4" 1 15'-5

1

4

"N/A N/A N/A

21" / 24"

2'-11" 17'-6" 3'-0" 4

1

2

" 2 18'-9"

N/A N/A N/A

27" / 30"3'-5

1

2

" 20'-9" 3'-0" 4

1

2

" 2 21'-8" 4'-8

1

8

" 17'-4

1

2

" 4'-3

1

2

"

33" / 36"

4'-0" 24'-0" 4'-0" 4

1

2

" 3 24'-11

3

8

" 7'-11

5

8

" 17'-4

1

2

" 7'-7"

42" 4'-6" 27'-3" 4'-0" 4

1

2

" 3 28'-7" 11'-2

7

8

" 17'-4

1

2

" 11'-2

1

2

"

48" 5'-1" 30'-6" 5'-0" 4

1

2

" 3 31'-10" 14'-6

3

8

" 17'-4

1

2

" 14'-6

1

8

"

4:1 Slope

Pipe Size

H L W

Grate Pipe Ø #Grate Pipes

L2 L3 L4 L5

12" 1'-10" 7'-4" 2'-0" 3

1

2

" 1 8'-6

3

4

"

N/A N/A N/A

15" / 18"

2'-4

1

2

" 9'-6" 2'-0" 3

1

2

" 1 10'-9

1

2

"

N/A N/A N/A

21" / 24"

2'-11" 11'-8" 3'-0" 4" 2 13'-0

1

4

"N/A N/A N/A

27" / 30"3'-5

1

2

" 13'-10" 3'-0" 4" 2 15'-3"N/A N/A N/A

33" / 36"

4'-0" 16'-0" 4'-0" 4

1

2

" 3 17'-6"

N/A N/A N/A

42" 4'-6

1

2

" 18'-2" 4'-0" 4

1

2

" 3 19'-5

3

8

"

N/A N/A N/A

48" 5'-1" 20'-4" 5'-0" 4

1

2

" 3 21'-11

1

4

" 10'-0

7

8

" 11'-10

1

2

" 10'-0

3

4

"

54" 5'-7

1

2

" 22'-6" 6'-0" 4

1

2

" 4 24'-2

1

8

" 12'-3

3

4

" 11'-10

1

2

" 12'-3

5

8

"

60" 6'-2" 24'-8" 6'-0" 4

1

2

" 4 26'-5

1

8

" 14'-6

5

8

' 11'-10

1

2

" 14'-6

5

8

"

3:1 Slope

Pipe Size

H L W

Grate Pipe Ø #Grate Pipes

L2

12" 1'-10" 5'-6" 2'-0" 3

1

2

" 1 6'-9

1

2

"

15" / 18"

2'-4

1

2

" 7'-1

1

2

" 2'-0" 3

1

2

" 1 8'-6

1

4

"

21" / 24"

2'-11" 8'-9" 3'-0" 3

1

2

" 2 10'-2

3

4

"

27" / 30"

3'-5

1

2

" 10'-4

1

2

" 3'-0" 3

1

2

" 2 11'-11

1

4

"

33" / 36"

4'-0" 12'-0" 4'-0" 4" 3 13'-7

3

4

"

42" 4'-6

1

2

" 13'-7

1

2

" 4'-0" 4" 3 15'-0

5

8

"

48" 5'-1" 15"-3" 5'-0" 4

1

2

" 3 16'-8

3

4

"

54" 5'-7

1

2

" 16'-10

1

2

" 6'-0" 4

1

2

" 4 18'-5

3

4

"

60" 6'-2" 18'-6" 6'-0" 4

1

2

" 4 20'-2

1

4

"

6:1 Slope Pocket

Grate Pipe Ø

X Y

3

1

2

" 2

1

2

" 33"

4" 2" 36"

4

1

2

" 1

1

2

" 39"

All Slopes

a* b

Hole Opg

3

1

2

" 6

1

2

" 20"

5" / 2"7

1

2

" / 6

1

2

"24" / 28"

4" / 2

1

2

" 7" / 6

1

2

"

32" / 34"

4" / 1"7

1

2

" / 6

1

2

"38" / 42"

3" / 1"

7"

46" / 48"

0" 7" 56"

0" 8" 62"

0" 8" 70"

0" 8" 76"

4:1 Slope Pocket

Grate Pipe Ø

X Y

3

1

2

" 2 " 24"

4" 1

1

2

" 26"

4

1

2

" 1" 28"

3:1 Slope Pocket

Grate Pipe Ø

X Y

3

1

2

" 1

1

2

" 18"

4" 1" 19

1

2

"

4

1

2

"

1

2

" 21"

Page 19: Virginia Endwalls - Amazon S3€¦ · Endwalls Use Precast concrete endwalls are designed to anchor the pipe or box sections into the surrounding embankment, reduce hydraulic entrance

Curtain Wall Detail

A

A

TITLE

06-07-18

DATE

Precast Virginia Endwall

EW-11A-LA

Virginia Endwalls

20180607TED01

Section View A-A

Isometric View

Side View

Notes

1) This design is intended for precast structures produced by CP&P only.

2) Concrete compressive strength 4,000 psi minimum.

3) Bar reinforcement design conforms to ASTM A706 or A615, grade 60 rebar or WWR

reinforcement conforms to ASTM A1064, grade 65 minimum.

4) Use # 4 bars diagonally around opening. Length=hole opening + 8". Bend as

necessary at wall edges.

5) All exposed 90° edges may be chamfered.

6) Grates in accordance with VDOT EW-11A.

Elevation View

Plan View

Notes

1) This design is intended for precast structures produced by CP&P only, not for cast-in-place

construction.

2) Concrete compressive strength 4,000 psi minimum.

3) Steel reinforcing design conforms to ASTM A706 or A615, grade 60 rebar or WWR

conforming to the requirements of ASTM A1064, grade 65 minimum.

4) Opening 8" maximum larger than pipe outside diameter. Additional reinforcement around

opening.

5) For use with pipe skewed 0° to 45°. Opening to be adjusted accordingly.

6) Contractor to consult VDOT EW-1PC standards for installation details.

7) All exposed 90° edges may be chamfered.

8) Length and reinforcement may be increased as necessary for handling considerations.

Pipe Size

L H A

12'' 11'-6'' 2'-3'' 10'-7

1

2

"

15'' 14'-10'' 2'-7'' 14'-0"

18'' 17'-4'' 2'-10'' 16'-6"

21'' 22'-4'' 3'-4'' 21'-6

1

2

"

24'' 22'-4'' 3'-4'' 21'-6

1

2

"

3'-5"3'-0"

2

1

2

"

2

1

2

" 2

1

2

"L

2'-0"

6"

6"

3"

A

Curtain Wall

(5)

Curtain Wall Detail

H

8"

Pipe Opg

6"

2

1

2

"

6"

8"

2"

6"

8"

Page 20: Virginia Endwalls - Amazon S3€¦ · Endwalls Use Precast concrete endwalls are designed to anchor the pipe or box sections into the surrounding embankment, reduce hydraulic entrance

A

A

TITLE

06-11-18

DATE

Precast Virginia Endwall

EW-11A-LH

Virginia Endwalls

20180611TED01

Section View A-A

Isometric View

Side View

Notes

1) This design is intended for precast structures produced by CP&P only.

2) Concrete compressive strength 4,000 psi minimum.

3) Bar reinforcement design conforms to ASTM A706 or A615, grade 60 rebar

or WWR reinforcement conforms to ASTM A1064, grade 65 minimum.

4) Use # 4 bars diagonally around opening. Length=hole opening + 8". Bend as

necessary at wall edges.

5) All exposed 90° edges may be chamfered.

6) Grates in accordance with VDOT EW-11A.

Elevation View

Plan View

Notes

1) This design is intended for precast structures produced by CP&P only, not for cast-in-place

construction.

2) Concrete compressive strength 4,000 psi minimum.

3) Steel reinforcing design conforms to ASTM A706 or A615, grade 60 rebar or WWR

conforming to the requirements of ASTM A1064, grade 65 minimum.

4) Opening 8" maximum larger than pipe outside diameter. Additional reinforcement around

opening.

5) For use with pipe skewed 0° to 45°. Opening to be adjusted accordingly.

6) Contractor to consult VDOT EW-1PC standards for installation details.

7) All exposed 90° edges may be chamfered.

8) Length and reinforcement may be increased as necessary for handling considerations.

Pipe Size Pipe Opg

L H A

12'' 17

1

2

" 11'-4'' 2'-1'' 10'-7

1

2

"

15'' 21" 14'-8'' 2'-5'' 14'-0"

18'' 24

1

2

" 17'-2'' 2'-8'' 16'-6"

21'' 31

1

2

" 22'-2'' 3'-2'' 21'-6

1

2

"

24'' 31

1

2

" 22'-2'' 3'-2'' 21'-6

1

2

"

6"

L

3"

A

(5)

6"

6"

2'-0"

H

Pipe Opg

6"

3"

3'-0"

12"

6"

4"

6"

Page 21: Virginia Endwalls - Amazon S3€¦ · Endwalls Use Precast concrete endwalls are designed to anchor the pipe or box sections into the surrounding embankment, reduce hydraulic entrance

Slot Detail

Wall Thickness (in) 4 5 6 7 8 8 9 10 11 12

Top Thickness (in) 7 7.5 8 8 8 8 9 10 11 12

Bottom Thickness (in) 6 6 7 7 8 8 9 10 11 12

2 0.41 0.56

3 0.46 0.62 0.82 0.99

4 0.68 0.90 1.07 1.30 1.40 2.44 2.85

5 0.97 1.16 1.40 1.50 1.83 2.19

6 1.25 1.50 1.60 1.94 2.31 2.72 3.15

7 1.60 1.70 2.05 2.44

Product Dimensions

TITLE

05-30-18

DATE

Precast Virginia Endwall(EW-12) for

Pipe Underdrain

Virginia Endwalls

20180605TED16

Section View A-A

Isometric View

Side View

Notes

1) Endwall to be placed at the end of underdrain outlet and installed

perpendicular to roadway and flush with slope.

2) Concrete compressive strength 4,000 psi minimum.

3) Steel reinforcing design conforms to ASTM A706 or A615, grade 60 rebar

or WWR conforming to the requirements of ASTM A1064, grade 65 minimum.

4) Endwall accepts rigid nonperforated, smooth-bore pipe, 70 psi tested conforming

to the requirements of ASTM D2412.

5) The expanded steel mesh extends a minimum of 1" above the pipe OD.

6) The slot is for expanded steel mesh that allows easy removal for cleanout purposes.

7) Expanded steel mesh (rodent screen) to be galvanized with openings approximately

1

2" x 1" and weighs approximately 0.82 lbs psf conformimg to the requirements of

ASTM A123.

Plan View

Elevation Side ViewElevation Front View

Notes

1) This design is intended for precast structures produced by CP&P only, not

for cast-in-place construction.

2) Concrete compressive strength 4,000 psi minimum.

3) Steel reinforcing design conforms to ASTM A706 or A615, grade 60 rebar

or WWR conforming to the requirements of ASTM A1064, grade 65

minimum. Cover Cc of 1

1

2" minimum unless otherwise noted.

4) Opening 8" maximum larger than pipe outside diameter. Additional

reinforcement around opening.

5) For use with pipe skewed 0 to 45 degrees. Opening to be adjusted

accordingly.

6) Contractor to consult VDOT EW-1APC standards for installation details.

7) All exposed 90° edges chamfered

3

4 inch.

8) Length and reinforcement may be increased as necessary for handling

considerations.

Standard Dimensions

Pipe ID Slope

L H

4'' 2:1 2'-5

1

2

" 1'-2

3

4

''

4'' 3:1 3'-5

1

4

'' 1'-1

3

4

"

4" 4:1 4'-5'' 1'-1

1

4

''

6" 2:1 2'-10

1

2

'' 1'-5

1

4

''

6" 3:1 4'-

3

4

'' 1'-4

1

4

''

6" 4:1 5'-3'' 1'-3

3

4

''

H

12"

L

2

'

-

0

"

6

"

6

"

1

2

"

6"

6"

1"1"

3/8"

6"

6"

Expanded Steel Mesh (Flattened)

Pipe Coupler to be cast into Endwall.

Coupler must be flush with outer surface of

Ew-12 and provide a positive connection for

the outlet pipe (4" or 6").

Slope

1

"

1

4

"

1

2

"

3

8

"

1" Min

Page 22: Virginia Endwalls - Amazon S3€¦ · Endwalls Use Precast concrete endwalls are designed to anchor the pipe or box sections into the surrounding embankment, reduce hydraulic entrance

www.ConcretePandP.com © Copyright 2018 Concrete Pipe & Precast

Ashland, VA Charleston, SC

Hanover, VA Summerville, SC

Harrisonburg, VA Dunn, NC

Martinsburg, WV Oakboro, NC

Salem, VA Rincon, GA