    Solenoid Operated Directional ValvesCatalog

    DG4V-3 flows

    to 80 l/min

    (21 USgpm),

    6* design

    DG4V-3S flows

    to 40 l/min

    (10.5 USgpm),

    6* design

    ISO 440

    size 03; A

    B93.7M-

  • 5/26/2018 Vickers_DG4V-3_DG4V-3S_6x

    2/32

    Table of Contents

    Introduction 01

    Features and Benefits 02

    Characteristics 03

    Functional Symbols 04

    Model Code 05

    Operating Data 07

    Performance Data 09

    Installation Dimensions 12

    DG4V-3-*A(L)-(V)M-S6-U-**-60 14

    DG4V-3-*A(L)-(Z)-(V)M-S3-FPA5W-*2-60 14

    DG4V-3-*A(L)-(Z)-(V)M-S4-FPA5W-*2-60 14

    DG4V-3-*A(L)-(Z)-(V)M-S5-F-*2-60 14

    Electrical Plugs and Connectors 15

    Subplates, Connection Plates and Mounting Surfaces 18

    DGMA-3-B-1* Blanking Plate 19

    DGMA-3-C2-11 Crossover Plate 19

    DGMA-3-T*-1*-* Tapping Plate 19

    DGAM-3-01-1*-R (Metric bolt tapping) DGAM-3-01-1* (UNC bolt tapping) 20

    Adaptor plate, Size 05 to 03 for pressure up to 210 bar (3000 psi) 20

    DGVM-3-1*-*, DGMS-3-1E(Y)-1*-* Single station subplate, rear and side tapped port 21

    DGMS-3-3E-1*-* Multi-station subplate 22

    Mounting Surface 23

    Appendix 24

    Mounting Bolts 24Spare Parts Data 25

    Seal Kits 25

    Solenoid Coils 25

    Mass, approx. kg (lb) 25

    Mounting Attitude 25

    Temperature Limits 26

    Fluid Temperature 26

    Fluid Cleanliness 26

    Ordering Procedure 26

  • 5/26/2018 Vickers_DG4V-3_DG4V-3S_6x

    3/32

    EATON Vickers Solenoid Operated Directional ValvesProduct Catalog V-VLDI-MC011-E September 2008

    Introduction

    These solenoid operateddirectional control valves arefor directing and stoppingflow at any point in a hydrau-lic system. This 60-designseries has been speciallydesigned and developed tocover expanded demands inthe industry as well as themany traditional uses of theearlier designs. Some of themore important benefits tousers are outlined.

    Efcient control of greaterhydraulic powers withoutincreasing solenoid powerconsumption.

    Installed cost and spacesavings from higherpower/weight-and-sizeratios.

    Increases system efciency;the result of improvedmanufacture of spoolsand bores.

    General description

    Installation exibilityresulting from choice ofnumerous combinationsof solenoid connectorsand locations.

    Multi-uid capability with-out need to change seals.

    Higher sustained machineproductivity and higheruptime because of provenfatigue life and endurance,tested over 20 million

    cycles. Solenoid coils can be

    changed quickly andeasily without leakagefrom hydraulic system.

    Compact, cost effectivesystem design when usedwith VickersSystemStakvalves and subplates.

    DG4V-3 and DG4V-3SHigh and standardperformance models:

    Up to 80 l/min (21 USgpm)and up to 40 l/min (10.5USgpm) respectively at350 bar (5000 psi).

    Builds on Eaton's experi-ence as the major supplierof size 03 valves world-wide.

    Offers designers the

    opportunity to select theoptimum value packagefor each application.

    International standardinterface. The valvemounting face conformsto ISO 4401, size 03 andis compatible with relatedinternational standards.

    Features and Benefits

    High pressure and owcapabilities, thanks tospecial design features

    Highly reliable operation upto 80 l/min (21 USgpm) at350 bar (5000 psi). Estab-lishes new market standardsand opens new possibilitiesto design engineers on valvesize selection.

    Typical maximum pressuredifferential (P-A-B-T) flow en-velope, blocked center spool.

    10 20 30 40 50 60 70 80100

    200300

    400

    14502000

    30004000

    5000

    0 4 8 12 16 20 21

    DG4V-3S

    DG4V-3

    Flow rate (l/min)

    Flow rate (USgpm)

    Pressure

    differen

    tial(bar)

  • 5/26/2018 Vickers_DG4V-3_DG4V-3S_6x

    4/32

    2 EATON Vickers Solenoid Operated Directional ValvesProduct Catalog V-VLDI-MC011-E September 2008

    Surge supression forDC valves

    Surge suppression is usedto prevent coil damage byreducing contact burnoff increasing switch life andprotecting electrical control-lers from inductive spikes.

    Three coil options areavailable:

    D1 Encapsulated diode(Industrial application)

    D2 Encapsulated diode(Mobile application)

    D7 Transzorb type

    Features andBenefits

    Minimal pressure drop,i.e. 2,5 bar (36 psi) at30 l/min (7.9 USgpm)

    Achieved by optimization ofthe valve body, spool andspool-stroke design. Theresults: low energy consump-tion and improved efficiency.

    High reliability

    Design of spring forces andprofile of DC solenoid forcecharacteristics ensure spoolposition selection underextreme operating condi-tions. Result is a valve withhigh reliability when beingenergized or de-energied.

    Scratch-proof manualoverride seal

    Internal seals are locatedsuch that they are beyondreach of any bore damagecaused by small tools used tooperate the manual override.

    Result is no messy oil dripsfrom the manual overrides.

    Small diameter manual over-rides prevent inadvertentoperation.

    Ease of servicing

    Wet-armature solenoid,screw-in core tube designallows coils to be changedwithout removing valve frominstallation and without oilspillage or risk of contaminat-ing system fluid.

    Electrical connections

    Conduit box design thatsimplifies electrical wiringconnections to solenoids.

    Orientation tabs preventincorrect positioning.

    DG4V-3 High Performance

    DG4V-3S StandardPerformance

    ISO4400 (DIN 43650)coil shown

    Mounting surface toISO 4401 size 03

    P

    T

    BA

    Vickerssolenoid force

    Normal solenoidforce range on

    the marketVickers springforceNormal springforce range on

    the market

    Solenoidde-energized

    Solenoidenergized

    Performance leader

    Force

    10 20 30 40 50 60 70 800

    50

    100

    150

    2000 3

    DG4V-3S

    DG4V-3

    Flow rate (l/min)

    Flow rate (USgpm)

    Pressure

    differential

    bar

    Pressure

    differential

    psi

    18 21

    0246

    81012

    14151296

  • 5/26/2018 Vickers_DG4V-3_DG4V-3S_6x

    5/32

    EATON Vickers Solenoid Operated Directional ValvesProduct Catalog V-VLDI-MC011-E September 2008

    Characteristics

    High performanceDG4V-3, 6* design

    Standard performanceDG4V-3S, 6* design

    Mounting interface

    ISO 4401 size 03ANSI/B93.7M size D03CETOP RP65H, size 3DIN 24340, NG6

    Basic characteristics

    Maximum pressure:

    DG4V-3 350 bar (5075 psi)DG4V-3S 350 bar (5075 psi)

    Maximum flow:DG4V-3 up to 80 l/min

    (21 USgpm)DG4V-3S up to 40 l/min

    (10.5 USgpm)

    DG4V-3 models are directsolenoid operated four-waydirectional control valves.Their primary function in ahydraulic circuit is to directfluid flow. This, in turn, woulddetermine the direction of

    movement of a fluid cylinder,or the direction of rotation ofa fluid motor.

    Port connections are madeby mounting the valve ona subplate or manifold. Thevalve has wet armature typesolenoids.

    Electrical connections tothe valve are made in theelectrical wiring housing orthru various plug-in connec-tors such as a DIN 43650type coil.

    Good hydraulic design prac-tice suggests that detentedmodels be mounted withlongitudinal axis horizon-tal. Other models may bemounted in any position.

    Operating considerations

    1. Dependent on the applica-tion and the system filtration,any sliding spool valve if heldshifted under pressure forlong periods of time, maystick and not move readilydue to fluid residue forma-tion. It may therefore needto be cycled periodically toprevent this from happening.

    2. Surges of fluid in a com-mon tank line serving twoor more valves can be of

    sufficient magnitude to causeinadvertent shifting of thesevalves. This is particularlycritical in no-spring detentedmodels, separate drain linesare necessary.

    Temperature limits

    Minimum ambient-20C (-4 F)

    Maximum ambientValves with coils listed inmodel code and at statedpercentages of rated voltage.

    Construction of a typicalsingle solenoid model

    Fluid temperature

    FLUID TEMP. MINERAL OIL WATERCONTAINING

    Min 20C (-4F) +10C (+50F)

    Max.* +70C (+158F) +54C (+129F)

    * To obtain optimum service life from both fluid and hydraulicsystem, 65C (150F) normally is the maximum temperatureexcept for watercontaining fluids.

    COIL TYPE AND PERCENTAGE MAXIMUM AMBIENT TEMPERATURE

    FREQUENCY VOLTAGE DG4V-3 DG4V-3S

    Dual frequency coils

    @ 50 Hz 107% 40C (104F) 65C (149F)

    @ 50 Hz 110% 30C (86F) 65C (149F)

    @ 60 Hz 107% 50C (122F) 65C (149F)@ 60 Hz 110% 40C (104F) 65C (149F)

    Single frequency (50 Hz) coils

    @ 50 Hz 110% 40C (104F) 65C (149F)

    DC coils 110% 70C (158F) 70C (158F)

    For synthetic fluids consultmanufacturer or Eaton rep-resentative where limits areoutside those for mineral oil.

    Whatever the actual tempera-ture range, ensure that vis-cosities stay within the limitsspecied in the Hydraulicfluids section.

  • 5/26/2018 Vickers_DG4V-3_DG4V-3S_6x

    6/32

    4 EATON Vickers Solenoid Operated Directional ValvesProduct Catalog V-VLDI-MC011-E September 2008

    FunctionalSymbols

    Spool types shown repre-sent the highest proportionof market requirements. Forother spool functions that maybe required, consult yourEaton sales representative.

    Solenoids identified to U.S.standards

    Functional symbols related tosolenoid identity A and/orB according to NFPA/ANSIstandards, i.e. energizingsolenoid A gives flow P toA, solenoid B gives flow Pto B (as applicable).

    FOR

    SPOOL

    SOLENOID TYPE SOLENOID

    B All A

    except

    8

    A 8only B

    For valves with type 8spools,solenoid identity to U.S.convention is the same as forEuropean convention.

    Solenoids identified toEuropean standards(specify V in model code)

    Functional symbols relatedto solenoid identity A and/or B according to Europeanconvention i.e. solenoid A

    adjacent to A port, solenoidB adjacent to B port ofvalve.

    For differences in valve func-tion, refer to PerformanceData page 11.

    F build spools.

    U.S. solenoid standard

    Double solenoid valves,two position, detented

    Single solenoid valves,solenoid at port A end

    Single solenoid valves,solenoid at port B end

    Double solenoid valves,spring centered

    sTransient condition only

    sTransient condition only

    The valve function schematics apply to both U.S. and European valves.

    European solenoid standard

    DG4V-3(S)-*N(V)

    DG4V-3(S)-*C(V)

    DG4V-3(S)-8C(V)

    DG4V-3(S)-*A(V) DG4V-3(S)-*AL(V)

    DG4V-3(S)-*B/F(V) DG4V-3(S)-*BL/FL(V)

    DG4V-3(S)-8BL(V) DG4V-3(S)-8B(V)

    Double solenoid valves,two position, detented

    Single solenoid valves,solenoid at port A end

    Single solenoid valves,solenoid at port B end

    Double solenoid valves,spring centered

    Port APort P

    Port TPort B

    Solenoid

    A

    Solenoid

    B

    Port APort P

    Port TPort B

    Solenoid Solenoid

    P T

    A B

    B.loS A.loS

    P T

    A B

    B.loS A.loS

    P T

    A B

    Sol. B P T

    A B

    Sol. A

    2 0

    2

    22

    24

    0

    2

    22

    24

    0

    2

    6

    66

    7

    33

    34

    22

    25

    65

    0

    2

    7

    22

    125

    165

    33

    34

    6

    66

    0

    2

    7

    22

    25

    65

    33

    34

    6

    66

    8 88

    P T

    A B

    Sol. A Sol. B P T

    A B

    Sol. A Sol. BP T

    A B

    P T

    A B

    Sol. A Sol. B

  • 5/26/2018 Vickers_DG4V-3_DG4V-3S_6x

    7/32

    EATON Vickers Solenoid Operated Directional ValvesProduct Catalog V-VLDI-MC011-E September 2008

    Model Code

    DG4V3(S)** *(L)(**)(V)M(S*)* ** * D* (L)* *6*(EN***)(P**A**B**

    1 Model Series

    D Directional valve

    G Subplate/manifold mounted

    4 Solenoid operated

    V Pressure rating 350 bar(5075 psi) on P, A & B ports

    2 Standard or highperformance

    3 High performance speci-cation: up to 80 l/min (21USgpm) at 350 bar (5075 psi)

    3S Standard performancespecification: up to 40l/min (10.5 USgpm) at350 bar (5075 psi)

    3 Spool type

    See Functional symbols section.

    4 Spool SpringArrangement

    A Spring offset, end-to-end

    AL Same as A but left

    hand buildB Spring offset, end to center

    BL Same as B but lefthand build

    C Spring centered

    F Spring offset, shift to center

    FL Same as F but lefthand build

    N No-spring detented

    5 Manual override option

    No symbol Plain override(s)in solenoidend(s) only s

    H Water-resistant override(s)on solenoid end(s) s

    H2 Water-resistant overrideboth ends of solenoid.

    P2 Plain override both endsof single solenoid.

    Yl Latching manual over-ride on solenoid ends(includes H featureseal) s

    Z No overrides at either end

    s No override in non-solenoidend of single solenoid valves

    lNot available on DG4V-3S,AC models

    6 Solenoid energizationidentity

    V Solenoid A is at port Aend and/ or solenoid B isat port B end, indepen-dent of spool type

    Omit for U.S. ANSI B93.9standard requiring solenoidA energization to connectP to A and/or solenoid B toconnect P to B, independentof solenoid location.

    NOTE:Type 8 spool valvesconform to both U.S. andEuropean solenoid designa-tions. When ordering an 8spool, designate a V in themodel code.

    7 Flag symbol

    M Electrical options andfeatures

    8 Spool indicator switch

    Available on high performance

    models, DG4V-3, only. Omitwhen not required.

    DG4V-3-*A(L)-(V)M modelswith type U (ISO4400) electri-cal connector to solenoid;spool type 0, 2 or 22 only:

    S6 LVDT type DC switch withPg7 connector plug.

    DG4V-3-*A(L)-(Z)-(V)M-S*-FPA5Wvalves with mechanical typeAC (~) switch, wired to 5-pinreceptacle:

    S3 Switch, wired normally open

    S4 Switch, wired normallyclosed

    DG4V-3-*A(L)-(Z)-(V)M-S5-F(T)W/J valves with mechanicaltype AC (~) switch:

    S5 Switch, free leads

    9 Coil type

    U ISO 4400 (DIN 43650)mounting u

    U1 Connector fitted

    U6 Connector fitted w/lights

    U11 Connector fittedw/rectifier & lights**

    U12 Connector fittedw/rectifier**

    F 1/2" NPT thread

    conduit boxKU Top exit flying leads*

    SP1 Single 6,3 mm spade* u

    SP2 Dual 6,3 mm spade* u

    X1 Flame resistant sole-noids TP EEx-d-11B-T4

    X2 Hazardous locationsolenoids to meetUL & CSA approval

    X3 Special protectionsolenoids to BASEEFAstandar SFA009:1972,protection class EX-S-11-T4

    uFemale connector to besupplied by customer

    * DC service only

    ** AC service only

    10 Electrical connector

    T Wired terminal block

    PA Instaplug malereceptacle only

    PB Instaplug male &female receptacle

    PA3 Three pin connector

    PA5 Five pin connector

    7654321 8 9 1210 1311 14 1615 1817

    11 Housing (F type coil

    W 1/2" NPT threadwiring housing

    J 20 mm thread wiringhousing

    12 Surge suppressor/damper

    D1 Encapsulated diode(Industrial applicatio

    D2 Encapsulated diode(Mobile applications

    D7 Transzorb type(F,KU,U,SP1,SP2 on

    13 Solenoid indicator

    Not available on PA, KU, SP1& SP2

    14 Coil rating

    Full power coils, seeOperating Data.

    A 110V AC 50Hz

    B

    110V AC 50Hz/120V ACC 220V AC 50 Hz

    D 220V AC 50 Hz/240V AC

    G 12V DC

    H 24V DC

    For DG4V-3 only (not usawith DG4V-3S):Low power coils, see OpData. (Not available with No-spring detented mode

    BL 110V 50 Hz/120V 60

    DL 220V AC 50 Hz/240V A

    GL 12V DCHL 24V DC

    For 60 Hz or dual frequ

    Contact your Eaton repretive for additional coil voloptions.

  • 5/26/2018 Vickers_DG4V-3_DG4V-3S_6x

    8/32

    6 EATON Vickers Solenoid Operated Directional ValvesProduct Catalog V-VLDI-MC011-E September 2008

    Model Code

    DG4V3(S)** *(L)(**)(V)M(S*)* ** * D* (L)* *6*(EN***)(P**A**B**T**)

    15 Port T code

    Refer to Operating Data forport T pressure ratings.

    2 10 bar (150 psi) for spoolposition indicator modelsS3, S4 and S5.

    4 70 bar (1000 psi)

    5 100 bar (1500 psi) for stan-dard performance models,DG4V-3S, with AC or DCsolenoids.

    6 207 bar (3000 psi) for AChigh performance models,DG4V-3, including spoolposition indicator type S6.

    7 207 bar (3000 psi) for DChigh performance models,DG4V-3, including spoolposition indicator type S6.

    16 Design number

    60 Basic design

    61 Type 8 spool

    17 Special features

    EN*** code numberassigned as required.

    EN21 CSA approved modelswith 1/2 NPT entryconduit box, type FWand solenoid coil letterB,D,G, or H.

    18 Port restrictor plugs

    For details of plug orifice sizes

    and how to specify in modelcode see page 15. May befitted to valves by agreementwith your Eaton representative.

    Omit No restrictor plugsfitted

    7654321 8 9 1210 1311 14 1615 1817

  • 5/26/2018 Vickers_DG4V-3_DG4V-3S_6x

    9/32

    EATON Vickers Solenoid Operated Directional ValvesProduct Catalog V-VLDI-MC011-E September 2008

    Operating Data

    Performance data is typical with fluid at 36cSt (168 SUS) and 50C (122F).

    STANDARD PERFORMANCE VALVE HIGH PERFORMANCE VALV

    FEATURE DG4V-3S DG4V-3

    Pressure Limits

    P, A and B ports 350 bar (5075 psi) n 350 bar (5075 psi) T port: Spool indicator switch models Types S3, S4, S5 N/A 10 bar (145 psi) Type S6 N/A 210 bar (3045 psi) All other models 100 bar (1450 psi) 210 bar (3045 psi)

    Flow rating See performance data See performance data

    Relative duty factor Continuous; ED = 100% Continuous; ED = 100%

    Type of protection:

    ISO 4400 coils with plug fitted correctly IEC 144 class IP65 IEC 144 class IP65 SP1 Single spade 6,3 mm IEC 760 IEC 760 SP2 Dual spade 6,3 mm IEC 760 IEC 760 Coil winding Class H Class H Lead wires (coils type F***) Class H Class H Coil encapsulation Class F Class F

    Permissable voltage fluctuation:

    Maximum Refer to temperature limits. Refer to temperature limits. Minimum 90% rated 90% rated

    Typical response times at 100% rated volts measured fromapplication/removal of voltage to full spool displacement of 2C spool at:

    Flow rate P-A, B-T 20 l/min (5.3 USgpm) 40 l/min (10.6 USgpm) Pressure 175 bar (2537 psi) 175 bar (2537 psi) AC (~) energizing 18 ms 15 ms AC (~) deenergizing 32 ms 23 ms

    DC (=) energizing 60 ms 45 ms DC (=) deenergizing 40 ms 28 ms

    Power consumption, AC solenoids Initial s Holding Initial s Holding

    (for coils listed in model code). VA (RMS) VA (RMS) VA (RMS) VA (RMS)

    Full power coils:

    Single frequency coils AC 50 Hz 225 39 265 54 Dual frequency coils at 50 Hz 265 49 280 61 Dual frequency coils at 60 HZ 260 48 300 58

    Low power coils, BL and DL:(Not available with N No-spring detented models) Low power coils not usable 170 37

    Dual frequency coils at 50 Hz with DG4V-3S valves. 190 37Dual frequency coils at 60 Hz

    Power consumption, DC solenoids at rated voltage and 20 C (68 F).

    Full power coils:

    12V, model type G 30W 30W 24V, model type H 30W 30W

    Low power coils:

    12V, model type GL Low power coils not usable 18W 24V, model type HL with DG4V-3S valves. 18W

    nFor applications where valves are to remain pressurized (either energized or de-energized) at pressures over 210 bar (3045 pswithout frequent switching, it is recommended to use the high performance model, DG4V-3.

    s 1st half cycle; armature fully retracted.

  • 5/26/2018 Vickers_DG4V-3_DG4V-3S_6x

    10/32

    8 EATON Vickers Solenoid Operated Directional ValvesProduct Catalog V-VLDI-MC011-E September 2008

    Operating Data

    Spool Position IndicatorModels, high performancevalve DG4V-3 ONLY

    Spool/spring arrangementtypes 0A (L), 2A(L), 22A(L)

    DC model type S6(see page 14 for InstallationDimension)

    This product has beendesigned and tested tomeet specific standards out-lined in the European Electro-magnetic Compatibility.

    Directive (EMC) 89/336/EEC,amended by 91/263/EEC,92/31/EEC and 93/68/EEC,article 5. For instructions oninstallation requirements to

    achieve effective protectionlevels see this leaflet and theInstallation Wiring Practicesfor Eaton's VickersElectronicProducts leaflet 2468. Wiringpractices relevant to thisDirective are indicated by

    ElectromagneticCompatibility (EMC).

    Input:

    Supply voltage 10 to 35V DC inclusive of a maximum 4V pk-to-pk ripple

    Current, switch open 5 mA

    Current, switch closed 255 mAOutput:

    Voltage 1V below input at maximum load

    Maximum continuous current 250 mA

    Maximum load impedance 136at maximum input volts

    Maximum switching frequency 10 Hz

    Plug connections:

    Pin 1 (output 1) Normally open (ie. not connected to pin 3)

    Pin 2 Supply +ve

    Pin 3 0V

    Pin 4 (output 2) Normally closed (ie.connected to pin 3)

    Switching point Within the spool spring offset condition

    Connector Pg7 plug (supplied with valve)

    Protection Overload and short-circuit protected; self re-setting. IEC 144 class IP65 with connector correctly fitted.

    Factory setting ensures this condition under all combinations of manufacturing tolerance and of temperature drift (see Temperature Limits).

    Wiring Connections

    Warning

    All power must be switchedoff before connecting ordisconnecting any plugs

    WARNING:Electromagnetic Compatibility (EMC)

    It is necessary to ensure that the unit is wired up in accordance with the connection arrangements shown above.For effective protection the users electrical cabinet, the valve subplate or manifold and the cable screens should beconnected to efficient ground points.

    In all cases both valve and cable should be kept as far away as possible from any sources of electromagneticradiation such as cables carrying heavy current, relays and certain kinds of portable radio transmitters, etc. Difficultenvironments could mean that extra screening may be necessary to avoid the interference.

    Micro-switch type S3, S4 and S5

    Voltage 250V maximum 50/60 Hz

    Maximum current 5A

    Electricpanel

    Customers protective ground connection

    SolenoidLVDT

  • 5/26/2018 Vickers_DG4V-3_DG4V-3S_6x

    11/32

    EATON Vickers Solenoid Operated Directional ValvesProduct Catalog V-VLDI-MC011-E September 2008

    Performance Data Typical with mineral oil at36 cSt (168.6 SUS) and aspecific gravity of 0.87.

    Maximum ow rates

    Performance based on power solenoid coils waand operating at 90% ravoltage.

    See note at bottom of npage when using low pcoils (DG4V-3 models o

    DG4V-3S models (standard performance)

    Graph 1

    AC solenoid valves with dualfrequency coils operating at50 Hz

    Graph 2

    AC solenoid valves with

    Dual frequency coilsoperating at 60 Hz

    Graph 3

    DC solenoid valves

    s Consult Eaton regarding each application that will jointly flow rates approaching this curve and a pressurized voluexceeding 2000 cm3(122 cu.in.)

    Spool/spring Graph 1 Graph 2 Graph

    code curve curve curve

    0A(L) 1 1 3

    0B(L) & 0C, 0F 1 1 1

    2A(L) 5 5 3

    2B(L) & 2C, 2F 2 2 3

    2N 1 1 1

    6B(L) & 6C, 6F 6 6 5

    7B(L) & 7C, 7F 6 6 2

    8B(L) & 8C 8 s 7 s 8 s

    22A(L) 9 8 7

    22B(L) & 22C 7 7 6

    24A(L) 6 6 533B(L) & 33C 4 4 4

    34B(L) & 34C 6 6 5

    52BL, 52C, 6 6 5

    56BL & 56C 6 6 5

    66B(L) & 66C 3 3 5

    521B & 561B 6 6 5

    Pressure

    psi bar

    5000

    4000

    3000

    2000

    1000

    00 10 20 30 40 l/min

    0 2 4 6 8 10 USgpm

    Flow rate

    50

    100

    150

    200

    250

    300

    350

    9

    8

    7

    6

    5

    4

    32

    1

    0 10 20 30 40 l/min

    0 2 4 6 8 10 USgpm

    Flow rate

    psi bar

    5000

    4000

    3000

    2000

    1000

    0

    50

    100

    150

    200

    250

    300

    350

    Pressure

    1

    23

    4

    56

    7

    8

    Single frequency (50 Hcoils operating at 50 H

    0 10 20 30 40 l/min

    0 2 4 6 8 10 USgpm

    Flow rate

    psi bar

    5000

    4000

    3000

    2000

    1000

    0 0

    50

    100

    150

    200

    250

    300

    350

    P

    ressure

    1

    2

    3

    4

    5

    67

    8

  • 5/26/2018 Vickers_DG4V-3_DG4V-3S_6x

    12/32

    10 EATON Vickers Solenoid Operated Directional ValvesProduct Catalog V-VLDI-MC011-E September 2008

    Performance Data

    DG4V-3 models (high performance)

    Graph 4

    AC solenoid valves with:

    Graph 5

    AC solenoid valves with dual-frequency coils operating at 60 Hz

    Graph 6

    DC solenoid valves

    Spool/ Graph Graph Graphspring 4 5 6code curve curve curve

    0A(L) 2 2 3

    0B(L) & 0C, 0F 1 1 2

    2A(L) 2 2 3

    2B(L) & 2C, 2F 1 1 1

    2N 1 1 2

    6B(L) & 6C, 6F 6 5 6

    7B(L) & 7C, 7F 1 1 2

    8B(L) & 8C 5 s 4 s 5 s22A(L) 8 7 8

    22B(L) & 22C 7 6 7

    24A(L) 9 8 5

    33B(L) & 33C 4 3 4

    34B(L) & 34C 4 3 6

    52BL, 52C, 6 5 6

    56BL & 56C 6 5 6

    66B(L) & 66C 3 9 6

    521B & 561B 6 5 6

    s Consult Eaton regarding each application that will jointly haveflow rates approaching this curve and a pressurized volumeexceeding 2000 cm3 (122 cu.in.)

    Flow limits applicable tothe following usages:

    1. All valves except types22 and 52 spools havingsimultaneous equal flowrates from P to A or Band from B or A to T andS3, S4, S5 (limit switch)models.

    2. Valves with type 22 spoolshaving flow from P to A orB, the other being plugged.T is drained at all times.

    3. Valves with type 52 spoolshaving one service port (Aor B as appropriate) con-nected to the full bore endof a 2:1 area ratio double-acting cylinder and theother to the annulus end.

    4. Consult Eaton, withapplication details, if eitherof the following usagesare required:

    (a) Single flow path, i.e. P toA, P to B, A to T or B to T.

    (b) Substantially differentsimultaneous flowrates between P to Aor B and B or A to T, e.g.when A and B areconnected to a cylinderhaving a large differen-tial area.

    Low Power Coils(DG4V-3 models only)

    When using low power coils(coil designations *L in modelcode) the maximum flow is

    reduced from values given onthis page (graphs 4, 5 and 6)by up to:

    70% for DC coils

    50% for AC coils

    depending on spool type.Consult your Eaton repre-sentative relative to specificapplications for low powercoils.

    Single-frequency coils

    Dual-frequency coilsoperating at 50 Hz

    psi bar

    0 3 6 9 12 15100 20 30 40 50 60 l/min

    USgpm

    350

    300

    250

    200

    150

    100

    50

    0

    1000

    2000

    3000

    4000

    5000

    Pressure

    1

    23

    45

    6

    7

    8

    7 & 9

    9

    5

    Flow rate

    psi bar

    350

    300

    250

    200

    150

    100

    50

    0

    1000

    2000

    3000

    4000

    5000

    Pressure

    100 20 30 40 50 60 l/min0 3 6 9 12 15 USgpm

    1

    2

    3

    94 8

    4 86

    5

    7

    3

    5

    0 10 20 30 40 50 60 70 80 l/min

    0 3 6 9 12 15 21 USgpm18

    psi

    0

    1000

    2000

    3000

    4000

    5000

    Pressure

    bar350

    300

    250

    200

    150

    100

    50

    1

    2

    3

    4

    5

    6

    7

    8

    5

    2,34 & 6

    Flow rate

    4

    6

  • 5/26/2018 Vickers_DG4V-3_DG4V-3S_6x

    13/32

    EATON Vickers Solenoid Operated Directional ValvesProduct Catalog V-VLDI-MC011-E September 2008

    Performance Data

    Pressure drops

    tCurve for spool type 6: not recommended for flows in excess of 60 l/min (15.8 USgpm).

    Pressure drops in offset positions except where otherwise indicated

    For other viscosities, prsure drops approximate

    Viscosity cSt (SUS)

    14 20 43 54 65 7

    (17.5) (97.8) (200) (251) (302) (3

    % of p

    81 88 104 111 116 1

    A change to another spgravity will yield an appmately proportional chain pressure drop.

    The specific gravity of amay be obtained from iproducer. Fire resistant usually have higher spegravities than oil.

    Spool/spring Spool P to A P to B A to T B to T P to T B to Acode positions or covered A to B

    0A(L) Both 5 5 2 2

    0B(L) & 0C, 0F De-energized 4s Energized 4 4 2 2

    2A(L) Both 6 6 5 5

    2B(L) & 2C, 2F Energized 5 5 2 2

    2N Both 6 6 3 3

    6B(L) & 6C, 6F De-energized 3s 3

    Energized 6 6 1 1

    7B(L) & 7C, 7F De-energized 6s 6 7m

    Energized 4 4 3 3

    8B(L) & 8C All 9 9 5 5 3

    22A(L), 22B(L) & 22C All 6 6

    24A(L) De-energized 6 6 2 2

    33B(L) & 33C De-energized 15s 15

    Energized 5 5 2 2 34B(L) & 34C De-energized 14s 14

    Energized 5 5 2 2

    52BL & 52C Energized 6s 6 2 10m

    56BL Both 6s 6 11s 10 10m

    56C De-energized 11s 10 10m

    Energized 6s 6 2 10m

    66B(L) & 66C De-energized 12 12 13

    Energized 6 6 2 2

    521B All 6s 6 10m

    561B De-energized 10s 11 10m

    Energized 6 6 10m

    s

    B plugged

    A pluggedm

    P plugged

    10 20 30 40 50 60 70 800

    2

    4

    6

    8

    10

    12

    0 3 6 9 12 15 18 21

    160

    140

    120

    100

    80

    60

    40

    20

    0

    Pressure

    drop

    Flow rate

    l/minUSgpm

    psi bar 12 11 10 9 8 7 6 5 4 32

    1

    DG4V-3SDG4V-3

    10 20 30 nim/l00 2 4 6 8 USgpm

    140

    120

    100

    80

    60

    40

    20

    15

    14

    13

    psi bar2000

    1600

    1200

    800

    400

    0

    DG4V-3S & DG4V-3Flow rate

    Pressure

    drop

  • 5/26/2018 Vickers_DG4V-3_DG4V-3S_6x

    14/32

    12 EATON Vickers Solenoid Operated Directional ValvesProduct Catalog V-VLDI-MC011-E September 2008

    Single solenoid modelss

    DG4V-3(S)-*A(-**) n

    DG4V-3(S)-*B(-**) n

    DG4V-3(S)-8BL(-**)

    DG3V-3(S)-*F n

    InstallationDimensions

    Models for use with ISO 4400 (DIN 43650) connectors

    Double solenoid models s

    DG4V-3(S)-*C-**-(V)M-U-**-60

    DG4V-3(S)-*N-**-(V)M-U-**-60

    DG4V-3(S)-*AL(-**)n

    DG4V-3(S)-*BL(-**)n

    DG4V-3(S)-8B(-**)

    DG4V-3(S)-*FL(-**)n

    3rd angleprojection

    nNot applicable to type 8 spool.sSee page 25 for solenoid information. Can vary dependent on source of plug.

    Model type AC or DC A Dim. B Dim. C Dim. D Dim.

    All DC = 220 (8.66) 156 (6.14) 61 (2.5) 73 (2.87)

    DG4V-3 AC ~ 200 (7.87) 146 (5.75) 51 (2.1) 63 (2.48)

    DG4V-3S AC ~ 200 (7.87) 146 (5.75) 45 (1.7) 63 (2.48)

    Water-resistant manual override on solenoid

    DG4V-3(S)-****(L)-H-(V)M-**-**-60

    Application

    General use where finger operation is required (standard manualoverrides cannot be operated without using small tool).

    Note:H feature is not eld convertible from other models;specify with order.

    Latching manual override on solenoid

    DG4V-3-****(L)-Y-(V)M-**-**-60 DG4V-3S-****(L)-Y-(V)M-**-**-60, DC coil models only

    Application

    Stainless steel lever/latch mechanism and water-resistant sealmake this feature ideal for vehicle-mounted and exposedapplications requiring emergency selection of valve for a periodof time in the event of electrical failure.

    Notes:

    1. Opposite solenoid (on C and N double solenoid models)should not be energized while the valve is latched in selectedposition; AC solenoid coils will burn out under

    this improper usage.2. Y feature is eld-convertible from H type manual override

    (omitting spacer), but is not field-convertible from other models

    Asshown

    Spolenoidand end capinterchanged

    24,00

    (0.94)

    Coil types: U (shown), KU, SP1,and SP2 (see Model Code)

    A (double solenoid model)

    87,0(3.42)

    53,00(2.1)

    B (single solenoid model)

    21,75(0.86)

    25,00(0.98)

    100,0(4.0)

    D 74,00(2.91)

    48,00(1.88)

    Alternative plug positions byloosening knurled nut, turningcoil, and re-tightening.

    Port APort P

    Port TPort B

    C, coillength

    Spacer

    15(0.6)

    Overall length of valve withstandard manual overrides

    Manualactucation mustbe applied within

    this diameter:approximately20(0.75).Spacer preventsactuation bylarger device.

    Overall length ofvalve with standardmanual overridesLever in latched position

    Lever in free position Lift latch to

    release lever

    65(2.5)

    40(1.6)

    Push lever tooperate valve;latch holds lever inoperated position

    Dimensions in mm(in).

  • 5/26/2018 Vickers_DG4V-3_DG4V-3S_6x

    15/32

    EATON Vickers Solenoid Operated Directional ValvesProduct Catalog V-VLDI-MC011-E September 2008

    InstallationDimensions

    Models with F type coils (lead wires) and conduit box.

    Double solenoid models s

    DG4V-3(S)-*C-**-(V)M-F-**-60DG4V-3(S)-*N-**-(V)M-F-**-60

    Single solenoid models s

    DG4V-3(S)-*A(-**)l

    DG4V-3(S)-*B(-**)l

    DG4V-3(S)-8BL(-**)

    DG3V-3(S)-*Fl

    DG4V-3(S)-*AL(-**)l

    DG4V-3(S)-*BL(-**)l

    DG4V-3(S)-8B(-**)

    DG4V-3(S)-*FL(-**)l

    Dimensions in mm(in).

    Asshown

    Spolenoidand end capinterchanged

    Model type AC or DC A Dim. B Dim. C Dim. D Dim.All DC = 220 (8.66) 156,5 (6.14) 61 (2.5) 73 (2.87)

    DG4V-3 AC ~ 200 (7.87) 146,5 (5.75) 51 (2.1) 63 (2.48)

    DG4V-3S AC ~ 200 (7.87) 146,5 (5.75) 45 (1.7) 63 (2.48)

    lNot applicable to type 8 spool. sSee page 24 for solenoid information.

    Codes FJ and FW: 2 lead wires for each solenoid, approximately 150,00 (6.00) long. M3 (#6)terminals provided for customer connection.

    Codes FTJ and FTW: Valve supplied with lead wires connected into terminal strip suitablefor M3 (#6) terminals for customer connection.

    47(1.85)

    Groundconnection4,0 (0.16 dia.)selftappingscrew

    Two leadwires per

    solenoid withM3 size

    terminals forcustomer

    connections

    24,00(0.94)

    25,00(0.98)

    3,0(0.12)

    *J & W conduit boxes

    Thread connectionW NPTJ M20 1.5-8H

    91,00(3.57)

    21,75(0.86)

    48,00(1.88)

    50,00(2.0)

    A (double solenoid models)

    B (single solenoid models)

    C coillength

    D74,00(2.91)

    68,75(2.71)

    53,00(2.1)

    Port APort P

    Port TPort B

    * 89 (3.5) for FPB J & W conduit boxes104 (4.0) All plug-in conduit boxes

  • 5/26/2018 Vickers_DG4V-3_DG4V-3S_6x

    16/32

    14 EATON Vickers Solenoid Operated Directional ValvesProduct Catalog V-VLDI-MC011-E September 2008

    InstallationDimensions

    DG4V-3-*A(L)-(V)M-S6-U-**-60

    DG4V-3-*A(L)-(Z)-(V)M-S3-FPA5W-*2-60DG4V-3-*A(L)-(Z)-(V)M-S4-FPA5W-*2-60DG4V-3-*A(L)-(Z)-(V)M-S5-F-*2-60

    Single solenoid models withLVDT type switch indicat-ing when the spool is in thespring off-set position. ISO4400 (DIN 43650) connectionto solenoid; Pg7 connectionto switch.

    Single solenoid models withmechanical type switch moni-toring of spool movement.

    WarningWiring: See ElectromagneticCompatibility (EMC)warningnote on page 8.

    Port restrictor plugs

    Restrictor plugs are availablefor use in ports P, T, A or B.

    These can be used forrestricting flow or for circuitdampening. Restrictor plugsare not recommended foruse above 210 bar (3000 psi)system pressure.

    Typical model codes:

    DG4V-3(S)-**-M-**-**-60-P08

    (0.8 mm dia orifice in port P)

    DG4V-3(S)-**-M-**-**-60-P10-A10(1.0 mm dia orifice in portsP and A)

    RESTRICTOR PLUGSELECTION TABLE

    Code Orifice Part diameter number

    *00 Blank 694353

    *03 0,30 (0.012) 694341

    *06 0,60 (0.024) 694342

    *08 0,80 (0.030) 694343

    *10 1,00 (0.040) 694344

    *13 1,30 (0.050) 694345

    *15 1,50 (0.060) 694346

    *20 2,00 (0.080) 694347

    *23 2,30 (0.090) 694348

    * = P, T, A or B, as required

    n hhOrder in multiples of 25per part number

    Maximum port dia insubplate/manifold block:

    For steel and SG (ductile)iron: 7,0 (0.3)

    For gray iron: 6,5 (0.25)

    Dimensions in mm(in)

    248,2 (9.8) with DC solenoid

    238,2 (9.4) with AC solenoid

    For coil removal:64 (2.51) DC coil54 (2.12) AC coil

    138,2 (5.44)

    Location of solenoidfor RH build models

    Location of switchfor RH build models Plug (part no. 458939)

    supplied with valve

    Cable gland PG7:6,0 (0.24) dia.

    Pin number 2, supply +ve

    Pin number 3, 0V Pin number 1,normally open

    Pin number 4,normally closed

    For LH build (DG4V-3-*AL )solenoid and switch locationsare reversed.

    For LH build (DG4V-3-*AL )solenoid and switch locations are reversed. 200 (7.87) with AC solenoid

    210 (8.27) with DC solenoid

    100 (3.94)

    Location of switch and housifor RH build models

    Normally closed lead (Monitor switch)

    sleeving identification color white.Common lead (Monitor switch)sleeving identification color black.

    Normally open lead (Monitor switch)no color identification.

    Location of solenoidfor RH build models

    54 (2.12)for removalof switch hsg.

    See page 16 for details of connections

    to pre-wired 5-pin receptacle for:S3 normally open andS4 normally closed.Conduit box with leads, or

    pre-wired to NFPA T3.5.29-1980 receptacle.

    M5 x 0.8-6H threadfor plug extraction

  • 5/26/2018 Vickers_DG4V-3_DG4V-3S_6x

    17/32

    EATON Vickers Solenoid Operated Directional ValvesProduct Catalog V-VLDI-MC011-E September 2008

    Electrical Plugsand Connectors

    Terminal strip and lights

    For valves with type F coils.

    1. For DC coils the +velead(s) must be connectedto the terminal(s) marked +.When using 3-wire incom-

    ing leads to double solenoidvalves (i.e. common neutral)the inner pair of terminalsmust be interconnected.

    2. For correct light indica-tion of energized solenoidensure that solenoid leadsare correctly connected: light

    terminals are common weach outer pair of solenterminals according to tside with + mark.

    DG4V-3(S)---FPA---60DG4V-3(S)---FPBW---60

    Eaton 2-part Insta-Plugeliminates breaking electricalinputs for valve disconnect.A male half is pre-wired tothe valve body. The mating

    plug is inside a wire housingwith external terminals for

    machine wire connections.Captive thumb screws, whenloosened, permit the wirehousing to be pulled clear ofthe valve for disconnect. A

    longer ground post providesfirst make/last break ground

    connection.The PBW configuration com-bines both male and femaleplugs in the wiring housing fora self-contained plug-in unit.

    Optional solenoid indicalights are pre-wired to t

    female plug. Solenoids and/or B are identifiethe wiring housing.

    Insta-Plug

    PA configuration PBW configuration

    Dimensions in mm(in).

    Terminal strip(part number

    890345) clips tocover and can

    be field-fitted

    M3 x 0,5-6H screws(part number 186006)

    2 each end

    4 terminal screws M3 x 0,5-6H(part number 02-113355)

    Connections to solenoid A(or B, according to model type)

    Connections tosolenoid B

    (or A, accordingto model type)

    Rubber gasket

    Conduit box cover andnameplate complete withsealing gasket and 4 screws

    Anti-rotation tab ensurescorrect orientation of cover

    to junction box

    28,50(1.12)

    30,00(1.18)

    Light assembly is held in placeby end pair of M3 screws; canbe fitted to terminal strip.

    2 lenses in cover

    24,0(0.95)

    71,1(2.80)

    16,25(0.64)

    47,5(1.87)

    ref.

    Port A Port BPort A

    15,5 (0.61)

    20,25 (0.79)

    32,50(1.28)

    M4-6H thd.

    48,0(1.89)

    89,0(3.50) Ground connection

    in terminal box(ref.)

    WARNING TAGElectrical powermust bedisconnectedbefore removing orreplacing thisreceptacle.

    Customer connection solenoid at port Aend of body to female receptacle plate

    Customer connectionsolenoid at port B end ofbody to female receptacleplate

    69,0(2.72)

    ref.

    98,5(3.88)

    23,1 (0.91)

    Clearance to removefemale receptacle

    The conduit box dimensions used for the PA/PBW type connector are different fromthose on the other Ftype coil models.

    Port B

  • 5/26/2018 Vickers_DG4V-3_DG4V-3S_6x

    18/32

    16 EATON Vickers Solenoid Operated Directional ValvesProduct Catalog V-VLDI-MC011-E September 2008

    Electrical Plugsand Connectors

    NFPA Connector T3.5.29-1980

    DG4V-3(S)FPA3W(L)-**-60

    DG4V-3(S)FPA5W(L)-**-60

    DG4V-3S3-FPA5W(L)-**-60

    DG4V-3S4-FPA5W(L)-**-60

    The receptacle is a standardthree or five pole connectorwith shortened leads andterminals added. The fivepole plug has four leads 101,6(4.0) long and one 177,8 (7.0)

    long. The three pole plug hastwo leads 101,6 (4.0) longand one 177,8 (7.0). All wireshave underwriters recognizednon-solder insulated eyeletterminals. The green wire isused for the ground (earth)connection (No. 8 screw fur-nished). Valves are suppliedpre-wired.

    3 pin connectorUse with single solenoid valve

    Key model code designations:

    DG4V-3(S)-*A(L)(-**)-(V)M-FPA3W(L)

    DG4V-3(S)-*B(L)(-**)-(V)M-FPA3W(L)

    5 pin connectorUse with single solenoidvalve with S3 spool positionmonitor switch

    Key model code designa-tions:

    DG4V-3-*A(L)(-**)-(V)M-S3-FPA5W(L)

    5 pin connectorUse with single solenoid valve

    Key model code designations

    DG4V-3(S)-*A(L)(-**)-(V)M-FPA5W(L)

    DG4V-3(S)-*B(L)(-**)-(V)M-FPA5W(L)

    5 pin connectorUse with single solenoidvalve with S4 spool positionmonitor switch

    Key model code designa-tions:

    DG4V-3-*A(L)(-**)-(V)M-S4-FPA5W(L)

    5 pin connectorUse with double solenoid valve

    Key model code designations:

    DG4V-3-*C/N(L)(-**)-(V)M-S4-FPA5W(L)

    Female 3 & 5 pin connectorsare available from a DanielWoodhead Co., Brad HarrisonDiv. Distributor (847-272-7990)

    40903 Female connectorwith 12' lead for PA3conn.

    41308 Female connectorwith 12' lead for PA5conn.

    These are Brad Harrison #s.

    Connection details and model type/model code references

    68,75(2.71)

    16,00(0.62)

    0.875-16UN-2A thd. Warning tag:Electrical power must bedisconnected before removingor replacing electrical plug.

    12

    325,4 (1.00)

    hex (referenceall types)

    3 leadto solenoid

    1 green lead (ground)

    2 lead to solenoid

    41

    2 3

    54 lead tomonitorswitch, n.o

    1 lead to solenoid

    3 green lead (ground)

    5 lead tosolenoid

    2 lead to monitor switch,common

    4 lead tomonitorswitch, n.c.

    5 lead tosolenoid

    2 lead to monitor switch,common

    41

    2 3

    5

    1 lead to solenoid

    3 green lead (ground)

    41

    2 3

    54 leadcapped

    1 lead to solenoid

    3 green lead (ground)

    5 lead tosolenoid

    2 lead capped

    41

    2 3

    5

    4 lead tosolenoid A

    1 lead to solenoid B

    3 green lead (ground)

    5 lead tosolenoid B

    2 lead to solenoid A

  • 5/26/2018 Vickers_DG4V-3_DG4V-3S_6x

    19/32

    EATON Vickers Solenoid Operated Directional ValvesProduct Catalog V-VLDI-MC011-E September 2008

    Electrical Plugsand Connectors

    Cable diameter range: 610 mm (0.240.40)

    Wire section range: ,51,5 mm2 (0.00080.0023 in2)

    Terminals: Screw type

    Type of protection: IEC144 class IP65, whenplugs are fitted correctly tothe valves with interfaceseals (supplied with plugs)in place.

    DIN 43650 Connector

    Connector can be positioned

    at 90 intervals on valve byre-assembling contact holderinto appropriate positioninside connector housing.

    Use U12 or U11 type connec-tors with 12 and 24V DC coilsif rectification is required.

    Connectors with and withoutindicator lights are available(order separately):

    Recptacle Voltage Part Numbers

    (AC or DC) Gray Black "A" sol. "B" sol.

    U1 Coils 710776 710775without lights

    U6 Coils 12-24 977467 977466with lights 100-125 977469 977468 200-240 977471 977470

    U11 Rectified 12 DC 02-141358coils with 24 DC 02-141359lights 98-240 VDC 02-141360 200-240 VDC 02-141361

    U12 Rectified 02-141357coils withoutlights

    Surge Suppression Devices(For DC Valves)

    Standard diode

    Diode in parallel with coil.When switch (S1) is opened,the energy stored in the coilis trapped and dissipated bythe diode (D1).

    Works only with DC voltage

    Polarity dependent

    Increase drop out time

    Transzorb

    Diode and Zener diode in par-allel with coil. When switch(S1) is opened, the energystored in the coil is trappedand dissipated by the diode(D1) and Zener diode (Z1) andthe coil resistance.

    The Zener makes exact limi-tation of inductive spikes.

    Works only with DC voltage

    Polarity dependent

    NOTE: These surge suppres-sion devices are PolarityDependent. Proper biasingconditions must be metwhen installing/connectinga coil in a system.

    Valve Shift and DropoutTimes with and withoutSurge Suppression

    Shift Dropout

    CETOP 3

    Do Diode 23 60

    Diode Alone 23 131

    Diode/Zener 23 78

    CETOP 5

    Do Diode 70 50

    Diode Alone 70 158

    Diode/Zener 70 100

    Times represent cessatapplication of voltage toversus velocity (start/stof a cylinder using a sinsolenoid, spring offset v(time in milliseconds).

    Seal

    51(2.01)

    22(0.8

    M3thread

    1,(0.0

    30,5 sq.(1.20)

    26,5(1.04)27,5(1.08)

    18 sq.

    (0.71)

    Coil Coil

    (No 2)S

    1

    (No 1)

    (No 2)S

    1

    (No 1)

    D1

    D1

    Z1

  • 5/26/2018 Vickers_DG4V-3_DG4V-3S_6x

    20/32

    18 EATON Vickers Solenoid Operated Directional ValvesProduct Catalog V-VLDI-MC011-E September 2008

    Subplates, ConnectionPlates and MountingSurfaces

    General description

    This range of subplates andauxiliary connection platesare for use with size 3 valves.Optional BSPF or SAE/UNFpipe thread connections areavailable.

    The subplates fall into fivegroups:

    Single station subplateswith either side or rearentry ports for connectingto the main system.

    Multi-station manifoldshaving from two to sixstations. The two serviceports per station are ar-ranged along one side butthe pressure and tank linesare internally connected inparallel to each station.

    Tapping plates for insertionunder modules or valves toprovide access to servicelines, e.g. for pressuregage connection.

    Cross-over plates for inter-connecting two sets ofservice lines at the top ofmodule stacks when direc-tional valves are not fitted.

    Blanking plate for termi-nating a valve station e.g.when the station is not tobe used until later.

    The 2 to 6 multi-station sub-plates, when used togetherwith VickersSystemStakvalves, provide very compactcontrol assemblies.

    Plates having machined trap-ezoidal O-ring recesses aresupplied complete with VitonO-rings.

    On all models, the size 03mounting face includes adrilled hole (for a location pin)in conformance with ANSI/B93.7M) and (NFPA) size03. All Eaton size 3 valvesand auxiliary plates containa matching location pin toensure correct orientation ofthe mounting faces.

    Design number subject to change. No change of installation dimensions for designs 10 thru 19. R(or B) sufx ISO 228 (BSPF) ports and/or metric attaching bolt tappings. S sufx SAE/UNCports and/or UNC attaching bolt tappings.

    DESCRIPTION AND

    MAXIMUM PRESSURE FUNCTIONAL SYMBOL MODEL CODE

    Blanking plate DGMA3B1*

    250 bar (3600 psi)

    Crossover plate DGMA3C11*

    PA, BT

    250 bar (3600 psi)

    Crossover plate DGMA3C21*

    PB, AT

    250 bar (3600 psi)

    Tapping plate DGMA3T11*B

    Ports A and B DGMA3T11*S

    250 bar (3600 psi)

    Tapping plate DGMA3T21*B

    Ports P and T DGMA3T21*S

    250 bar (3600 psi)

    Adaptor size 05 to 03 DGAM3011*R

    207 bar (3000 psi) DGAM3011*

    (UNC valve mtg. bolts)

    Single station DGVM31*R

    subplate/manifold DGVM31*S

    Rear ports P,T,A,B

    250 bar (3600 psi)

    Single station DGMS31E1*R

    subplate/manifold DGMS31E1*S

    Side ports P,T,A,B

    250 bar (3600 psi)

    Multi-station subplate/ DGMS32/3E1*R

    manifold; side ports DGMS32/3E1*S

    P,T,A1,B1,A2,B2, etc.

    250 bar (3600 psi)

    2 station3 station

    Multi-station subplate/ DGMS34/5/6E1*R

    manifold; side ports DGMS34/5/6E1*S

    P,T,A1,B1,A2,B2, etc.

    250 bar (3600 psi)

    4 station

    5 station

    6 station

    P T B A

    P T B A

    P T B A

    P T B A

    BT

    AP

    P

    T

    B1 A 1

    P T B A

    P1 T1 B1 A 1

    B 2 A 2

    P2 T2 B 2 A 2

    P

    T

    B1 A 1

    P1 T1 B1 A 1

    B6 A 6

    P6 T6 B6 A 6

    Valve station 1 Valve station 2 6

    Valve station 1 Valve station 2 3

    Size 03

    Size 05

    P T B A

    P T B A

    P TAT

    B B A

  • 5/26/2018 Vickers_DG4V-3_DG4V-3S_6x

    21/32

    EATON Vickers Solenoid Operated Directional ValvesProduct Catalog V-VLDI-MC011-E September 2008

    46,0 (1.8)

    73,0(2.9)

    4 holes 5,6 (0.22 dia.)

    counterbored to 9,5 (0.374 dia)

    Nameplate

    P T B A

    P T B A

    22,0 (0.9)

    46,0 (1.8)

    75,0(3.0)

    48,5 (1.9)

    Nameplate

    A

    T

    B

    P

    A

    T

    B

    P

    24,4 (1.0)

    10,0 (0.4)

    22,0 (0.9)

    11,0 (0.43)

    P T B A

    P T B A

    20,0(0.78)

    46,0 (1.8)48,4 (1.9)

    75,0(3.0)

    Nameplate

    2 tapped portsfor DGMA3T*1*B, G 1/8 (1/8 BSPF)for DGMA3T*2*S, 7/16 20 UNF 2B (SAE)(for 1/4O.D. tubing)

    DGMA-2-T1-1**(Ports A and B)

    DGMA-2-T2-1**(Ports P and T)

    A

    TB

    P

    A

    TB

    P

    4 holes 5,6(0.22 dia.)

    InstallationDimensions

    DGMA-3-B-1* Blanking Plate

    DGMA-3-C2-11 Crossover Plate

    DGMA-3-T*-1*-* Tapping Plate

    Dimensions in mm(in).

  • 5/26/2018 Vickers_DG4V-3_DG4V-3S_6x

    22/32

    20 EATON Vickers Solenoid Operated Directional ValvesProduct Catalog V-VLDI-MC011-E September 2008

    InstallationDimensions

    DGAM-3011*R(Metric bolt tapping)DGAM-3011*(UNC bolt tapping)

    Adaptor plate, Size 05 to 03for pressure up to 210 bar(3000 psi)

    Size 3 valves can frequently beused in place of size 5 valves,typically for pilot control func-tions, or generally where thesystem flow rate is within thatof size 3 valves.

    The DGAM3 adaptor boltsto an existing size 5 interfaceand provides a size 3 mountingface for the smaller valves.

    Dimensions in mm(in).

    Size 03 Mounting Surface

    MODEL TAPPINGS FOR VALVE MOUNTING BOLTS

    DGAM3011*R M56H x 12 (0.47) deep

    DGAM3011* #1024 UNC2B x 12,7 (0.5) deep

    Size 05 Mounting Surface (seals included)

    Adaptor is supplied complete with bolts for mountingto size 5 interface:

    M6 bolts with type DGAM3011*R1/4" 20 UNC bolts with type DGAM3011*

    70,0 (2.75)31,0

    (1.22)

    90,4(3.56)

    54,0(2.12)

    18,3(0.72)

    31,75(1.25)

    46,0(1.81)

    12,0(0.47)

    0,75(0.03)

    40,5(1.59)

    5,3(0.21)

    14,2(0.56)

    28,4 (1.12)

    21,0 (0.83)

    Standard Tport (TA)

    Additional Tport (TB)

    4 holes for valvemountingbolts (see table)

    P TA B A

    Size 03

    Size 05

    P T B A

    TB

    PA

    B

    TA

    P

    B

  • 5/26/2018 Vickers_DG4V-3_DG4V-3S_6x

    23/32

    EATON Vickers Solenoid Operated Directional ValvesProduct Catalog V-VLDI-MC011-E September 2008

    InstallationDimensions

    Dimensions in mm(in).

    DGVM-3-1**DGMS-3-1E(Y)-1*-*

    Single station subplate,rear and side tapped port

    Model Ports P, A, T, B Thread at rear or side

    DGVM31*R Rear G3/8 (3/8 BSPF) xDGMS31E1*R Side 12,0 (0.47) deep

    DGVM31*S Rear 3/4 16 UNF2B x 14,3DGMS31E1S* Side (0.56) deep (SAE)

    DGMS31EY1S* Side 5/8 18 UNF2B x 12,7 (0.5) deep (SAE)

    T

    P

    DGMSDGVM

    72,0(2.83)

    84,0 (3.3)

    72,0 (2.83)

    19,75(0.78)

    6,0(0.24)

    84,0(3.31)

    35,0(1.37)

    20,0(.787)

    6,0(0.24)

    16,0 (0.63)

    5(

    35,0(1.38)

    12,75 (0.

    59,25(2.33)

    36,00(1.42)

    12,75 (0.5)

    4 holes tapped accordingto model type (see table)

    4 ports .750-16 UNF-2Bfor side ports.

    4 ports .750-16 UNFfor rear ports.

    5,6 (.22) dia. thru13,0 (.51) spotface

    to depth shown. 4

    holes for mounting.

    B

    T P

    A

    B

    P

    A

    T

    P T B A

  • 5/26/2018 Vickers_DG4V-3_DG4V-3S_6x

    24/32

    22 EATON Vickers Solenoid Operated Directional ValvesProduct Catalog V-VLDI-MC011-E September 2008

    Dimensions in mm(in).

    InstallationDimensions

    DGMS-3-3E-1*-*Multi-station subplate(3 station shown)

    Model A Dim. B Dim.

    DGMS32E(X)1** 121 (4.8) 108 (4.25)

    DGMS33E(X)1** 171 (6.8) 158 (6.22)

    DGMS34E1** 221 (8.7) 208 (8.19)

    DGMS35E1** 271 (10.7) 258 (10.15)

    DGMS36E1** 321 (12.7) 308 (12.12)

    Dimensions in mm(in).

    u Thru connection P and T ports on types DGMS-3-2EX-1*-*and DGMS-3-3EX-1*-*

    68,0(2.68)

    6,0(0.24)

    P

    T37,5(1.47)

    B

    A

    These two ports are presentin 4, 5, and 6 station models.Optional in 2 and 3 station

    models, specifyDGMS32EX1** orDGMS33EX1**

    4 holes per model typeBSPF ports: M5-6H x 12,0 (0.47) deepSAE ports: #10-24 UNC-2B x 12,5 (0.5) deep

    PT

    A

    P and T ports tappedaccording to model type:DGMS-*E(X)1*R:

    G1/2 (1/2 BSPF)DGMA-*E(X)-1*-S:3/4:-16 UNF-2B (SAE)

    68,0 (2.68)34,0

    (1.34)

    38,0(1.5)

    5,0(0.6)

    38,0(1.5)

    15,0(0,6)

    PT

    B1 A 1

    P1 T1 B1 A 1

    B 2 A 2

    P2 T2 B 2 A 2

    Valve Station 1 Valve Station 2

    B

    5,6 (0.22 dia.counterbored11,1 (0.438 dia).

    PT

    A

    B

    PT

    A

    B

    60,0(2.36)

    effectivebolt length

    P

    T

    50,0(1.97)

    50,0(1.97)

    35,0(1.38)

    A

    B

    A and B ports tapped

    according to model type:DGMS-*E(X)1*R:G3/8 (3/8 BSPF)DGMA-*E(X)-1*-S:3/4:-16 UNF-2B (SAE)

    PT

  • 5/26/2018 Vickers_DG4V-3_DG4V-3S_6x

    25/32

    EATON Vickers Solenoid Operated Directional ValvesProduct Catalog V-VLDI-MC011-E September 2008

    InstallationDimensions

    Mounting Surface

    When a subplate is not used,a machined pad must beprovided for mounting. Thepad must be flat within 0,01mm per 100 mm (0.0001" per1") and smooth within 0,8 m(32 in).

    The interface conforms toISO 4401-AB-03-4A (size 03)plus location pin hole

    ANSI/B93.7M (and NFPA)size 03 CETOP R35H4.2-03,

    plus location pin holeDIN 24340 Form A6, pluslocation pin hole

    Dimensional tolerance =0,2 ( 0.008) except whereotherwise stated.

    Prior to installing a valve,ensure that both valve andmounting surface are cleanand free from burrs.

    sISO 4401 gives dimensionsin mm. Inch conversionsare accurate to 0.01" unlessstated.

    n#10-24 UNC-2B optional

    12,7(0.5)

    40,5 0,1 (1.594 0.004)

    31,0 0,1(1.22 0.004)

    25,9(1.01)

    30,2 (1.890)

    21,5(0.85)

    70 (2.75) min.

    48(1.89min.

    5,1(0.20)

    15,5(0.61)

    4 holes, M5-6H x 12,0(0.47) min. full thread depth

    4 ports 6,3 (0.25 dia). For allVickers size 3 valves thisdiameter may be increased to7,5 (0.29 dia).

    P

    B

    T

    A

    4,0 x 4,3min. deep(0.16 dia x0.17 deep)for locating pin

    31,75 0,1(1.25 0.004)

    0,75 0,1(0.03 0.004)

    7,5 (0.29)

    Dimensions in mm(in).

  • 5/26/2018 Vickers_DG4V-3_DG4V-3S_6x

    26/32

    24 EATON Vickers Solenoid Operated Directional ValvesProduct Catalog V-VLDI-MC011-E September 2008

    Appendix

    Note:If not using Eaton's Vickersbolt kits, bolts must beto Grade 12.9 (ISO 898)or better.

    The required bolt lengthshould allow 0.40" (10 mm)thread engagement in thesubplate/manifold block.Bolts should be torqued to57 N.m (4462 lbf. in.) with

    threads lubricated. Prior toinstallation of DG4V-3 valve,ensure that both the faceof the valve and the face onwhich it is being mounted(i.e subplate, manifold,SystemStak valve or plate)is as clean as possible. Donot over tighten hold-downbolts beyond recommendedvalues.

    INCH BOLT KITS, #1024 UNC2B

    Size x length, in (mm)

    #10-24 x 12,7 (0.50) BK590715

    #10-24 x 19,05 (0.75) BK466847

    #10-24 x 25,4 (1.00) BK304

    #10-24 x 31,8 (1.25) BK590716

    #10-24 x 38,1 (1.50) BK306

    #10-24 x 44,4 (1.75) BK02-156494

    #10-24 x 50,8 (2.00) BKDG3698

    #10-24 x 57,2 (2.25) BK02-139165

    #10-24 x 60,3 (2.38) BK466849

    #10-24 x 69,9 (2.75) BK870017#10-24 x 69,9 (2.75) BKDGFNL- 694Mu

    #10-24 x 76,2 (3.00) BK02-156496

    #10-24 x 79,4 (3.13) BK466850

    #10-24 x 88,9 (3.50) BK466851

    #10-24 x 95,3 (3.75) BK869704

    #10-24 x 100 (3.94) BK466852

    #10-24 x 101,6 (4.00) BK02-156497

    #10-24 x 109,5 (4.31) BK466853

    #10-24 x 120,7 (4.75) BK466854

    #10-24 x 127,0 (5.00) BK02-156499

    #10-24 x 130,2 (5.13) BK466855

    #10-24 x 133,4 (5.25) BK02-156498#10-24 x 139,7 (5.50) BK466856

    #10-24 x 150,9 (5.94) BK466857

    #10-24 x 160,3 (6.31) BK466858

    #10-24 x 170,0 (6.69) BK466859

    #10-24 x 177,8 (7.00) BK890325

    Mounting Bolts

    METRIC BOLT KITS, M5

    Size x length, mm (in)

    M5 x 20 (0.79) BK466834M

    M5 x 25 (0.98) BK465723M

    M5 x 30 (1.18) BK616452M

    M5 x 40 (1.57) BK02156493M

    M5 x 50 (1.97) BKDG3699M

    M5 x 55 (2.17) BK986135M

    M5 x 60 (2.36) BK466836M

    M5 x 70 (2.76) BK464125M

    M5 x 75 (2.95) BK869720M

    M5 x 80 (3.15) BK466837MM5 x 90 (3.54) BK466838M

    M5 x 95 (3.74) BK869721M

    M5 x 100 (3.94) BK466839M

    M5 x 110 (4.33) BK466840M

    M5 x 120 (4.72) BK466841M

    M5 x 130 (5.12) BK466842M

    M5 x 140 (5.51) BK466843M

    M5 x 150 (5.91) BK466844M

    M5 x 160 (6.30) BK466845M

    M5 x 170 (6.69) BK466846M

    M5 x 200 (7.87) BK464468M

    METRIC BOLT KITS, M6

    Size x length, mm (in)

    M6 x 16 (0.63) BK534564M

    M6 x 20 (0.79) BK534565M

    M6 x 25 (0.98) BK534566M

    M6 x 30 (1.18) BK534567M

    M6 x 40 (1.57) BKDG01633Mu

    M6 x 45 (1.77) BK534569M

    M6 x 50 (1.97) BK534570M

    M6 x 55 (2.17) BK534571M

    M6 x 65 (2.56) BK534572M

    M6 x 70 (2.76) BK534573MM6 x 75 (2.95) BK534574M

    M6 x 80 (3.15) BK638873M

    M6 x 80 (3.15) BKDGFN01637Mu

    M6 x 85 (3.35) BK978478M

    M6 x 90 (3.54) BK534576M

    M6 x 100 (3.94) BK978479M

    M6 x 110 (4.33) BK978480M

    M6 x 115 (4.53) BK534580M

    M6 x 120 (4.72) BK534581M

    M6 x 140 (5.51) BK638878M

  • 5/26/2018 Vickers_DG4V-3_DG4V-3S_6x

    27/32

    EATON Vickers Solenoid Operated Directional ValvesProduct Catalog V-VLDI-MC011-E September 2008

    Appendix

    Spare parts data

    Refer to service drawingI3886S for spare partsand kit information.

    Seal kits

    For valves with spool indi-cator switch, model typesDG4V-3-*A-M-S*-60:kit no. 859049

    For other models seal kitsvary according to type ofcoil fitted:

    For U type coil:kit no. 858995

    For F type coil:kit no. 858996

    Note:Each seal kit coversa variety of models and mayhave redundant seals for aparticular model.

    No restrictions except forno-spring, detented modelsDG4V-3-*N and DG4V-3S-*Nwhich should be mountedwith the spool axis horizontal.These model types may beaffected by severe vibrationor shock, especially if a sole-noid is not held energized.

    DG4V-3 and U F

    DG4V-3S (DC) coils coils

    Single sol. valve 1,6 1,8

    (3.5) (4.0)

    Double sol. valve 2,2 2,3

    (4.8) (5.0)

    DG4V-3 and U F

    DG4V-3S (AC) coils coils

    Single sol. valve 1,5 1,6

    (3.3) (3.5)

    Double sol. valve 1,8 2,0

    (4.0) (4.4)

    Single sol. 2,0 2,0valve w/ position (4.4) (4.4)

    switch

    Mounting AttitudeMass, approx. kg (lb)

    AC coils

    Code Voltage/ Standard performance High performance

    frequency U type F type U type F type

    Full power coils:

    A 110V/50 Hz 02-101725 02-101730 507825 508166

    B 110/120V/50/60 Hz 02-101726 02-101731 507833 508169

    C 220V/50 Hz 02-101727 02-101732 507826 508167

    D 220/240V/50/60 Hz 02-101728 02-101733 507834 508170

    Low power coils:

    BL 110/120V/50/60 Hz N/A N/A 598562 698563

    DL 220/240V/50/60 Hz N/A N/A 866455 866457

    DC coils (Standard and high performance)

    Code Voltage U type F type SP1 type SP2 type KU typ

    Full power coils:

    G 12V 507847 508172 02111246 02-111166 021403

    H 24V 507848 508173 02111248 02-111168 021403

    Low power coils:

    GL 12V 507855 508175 N/A N/A N/A

    HL 24V 507852 508174 N/A N/A N/A

    Solenoid Coils

  • 5/26/2018 Vickers_DG4V-3_DG4V-3S_6x

    28/32

    26 EATON Vickers Solenoid Operated Directional ValvesProduct Catalog V-VLDI-MC011-E September 2008

    Appendix

    Ambient range:-20C to 70C (-4F to +158F)

    Fluid Temperature

    Fluid Mineral WaterTemp. oil containing

    Minimum -20C +10C

    (-4F) (+50F)

    Maximum* +70C +54C

    (+158F) (+129F)

    * To obtain optimum service life

    from both fluid and hydraulicsystem, 65C (150F) is therecommended maximumfluid temperature, except forwater-containing fluids.

    For synthetic fluids, consultuid manufacturer or Eatonrepresentative where limits areoutside those for mineral oil.

    Whatever the actual tempera-ture range, ensure that fluidviscosities stay within thelimits specied in HydraulicFluids.

    Temperature Limits

    Proper fluid condition is es-sential for long and satisfac-tory life of hydraulic compo-nents and systems. Hydraulicfluid must have the correctbalance of cleanliness, mate-rials and additives for protec-tion against wear of compo-nents, elevated viscosity andinclusion of air.

    Essential information onthe correct methods fortreating hydraulic fluid isincluded in Eaton publica-tion 561;Vickers Guide toSystemic ContaminationControl, available from yourlocal Eaton distributor or bycontacting Eaton, Incorpo-rated. Recommendations onfiltration and the selection ofproducts to control fluid con-dition are included in 561.

    Recommended cleanlinesslevels, using petroleum oilunder common conditions,are based on the highest

    fluid pressure levels in thesystem and are coded in thechart below. Fluids other thanpetroleum, severe service cy-cles or temperature extremesare cause for adjustment ofthese cleanliness codes. SeeEaton's Vickerspublication561 for exact details.

    Eaton products, as any com-ponents, will operate withapparent satisfaction in fluidswith higher cleanliness codesthan those described. Othermanufacturers will often rec-ommend levels above thosespecified.

    Experience has shown, how-ever, that life of any hydrauliccomponents is shortenedin fluids with higher cleanli-ness codes than those listedbelow. These codes havebeen proven to provide a longtrouble-free service life forthe products shown, regard-less of the manufacturer.

    Fire resistant fluids usuallyhave higher specific gravitiesthan oil. The specific gravityof a fluid may be obtainedfrom its producer.

    Fluid Cleanliness

    When placing an order,please specify full modeldesignations of valves,subplates and kits. Referto relevant Model Codesections.

    Ordering Procedure

    System Pressure Level

    bar (psi)

    Product

  • 5/26/2018 Vickers_DG4V-3_DG4V-3S_6x

    29/32

    This page left intentionally blank.

  • 5/26/2018 Vickers_DG4V-3_DG4V-3S_6x

    30/32

    This page left intentionally blank.

  • 5/26/2018 Vickers_DG4V-3_DG4V-3S_6x

    31/32

    This page left intentionally blank.

  • 5/26/2018 Vickers_DG4V-3_DG4V-3S_6x

    32/32

    EatonHydraulics Operations USA14615 Lone Oak RoadEden Prairie, MN 55344USATel: 952-937-9800Fax: 952-294-7722www.eaton.com/hydraulics

    EatonHydraulics Operations EuropeRoute de la Longeraie 71110 MorgesSwitzerlandTel: +41 (0) 21 811 4600Fax: +41 (0) 21 811 4601

    EatonHydraulics Operations Asia Pacific11th Floor Hong Kong New World Tower300 Huaihai Zhong RoadShanghai 200021ChinaTel: 86-21-6387-9988Fax: 86-21-6335-3912

    2008 Eaton CorporationAll Rights ReservedPrinted in USADocument No. V-VLDI-MC011-ESupersedes GB-2072BSeptember 2008