12
DESIGNWITHUSANDSAVEYOURCOST DESIGN WITH US AND SAVE YOUR COST Expertise In Fire Protection DESIGN COORDINATION 3D MODULING STOCK-LISTING ESTIMATION

Vermont India1

Embed Size (px)

Citation preview

Page 1: Vermont India1

DESIGN WITH US AND SAVE YOUR COST

DESIGN WITH US AND SAVE YOUR COST

Expertise In

Fire Protection

•DESIGN

•COORDINATION

•3D MODULING

•STOCK-LISTING

•ESTIMATION

Page 2: Vermont India1

We Vermont India are situated in state capital of Jharkhand at

Ranchi. Our design team have 15 year of experience in the field of

Fire Protection Design, Estimation, Coordination and 3d- muddling

and are fully dedicated to various United State clients all over the

states. To insure good quality work with in the time we have one sr.

design engineer dedicated for each company to understand their

way of design and requirements. We have office inside the Campus

of Software Technologies Parks of India to make working enjoyment

healthy and clean. Which have 24 hour electricity, high speed

internet and canteen facility in the Campus.

Page 3: Vermont India1

Sprinkler/Hydrant system design: We provide complete sets of drawings which includes, Detailing, Riser Diagram, Seismic Calculation (if needed), 3D Fire pump assembly diagram, Hydraulic Calculation.. The proven ability to develop, layout turn-key fire sprinkler systems, on time and on budget. We offer the unique combination of managerial and technical expertise essential to complete any new or retrofit fire sprinkler design project.

Expert Design Team, offering

Detailed Specs and Design Concepts

Feasibility Planning and Budgeting

Hydraulic Calculations.

Advanced 3D CAD Design Capabilities

Extensive Knowledge of Fire Protection Requirements and Codes.

Page 4: Vermont India1

Wet Pipe Fire Sprinkler System.

Fire Hydrant System.

Dry Fire Sprinkler System.

Deluge Fire Sprinkler System.

Pre-action Fire Sprinkler System.

ESFR Fire Sprinkler System.

In-Rack Fire Sprinkler System.

Page 5: Vermont India1

Fire pumps are necessary any time a water supply is not capable of providing the pressure required by the sprinkler system design. Occasionally, there is insufficient city supply or no water supply and the pump must be supplied from a ground storage tank or other static source.

We have designed pumps in accordance with NPFA 20, the standard for Installation of Stationary Pumps for Fire Protection.

We are regularly involved in the following types of electric and diesel motor driven fire pump assembly Designing:

Split Case Horizontal

Split Case Vertical

Vertical In-Line

Vertical Turbine

Packaged Skid Mounted

Page 6: Vermont India1

3D FIRE PUMP

Page 7: Vermont India1

Building Models and BIM Technology

Fire Suppression and Fire Sprinkler System Design

Vermont India has created 3D fire protection drawings since 2000. We currently have Specialized designers and the best fire protection software titles available.

Within the fire protection industry and fire sprinkler system design, we lead the pack with our advanced software, 3D capabilities, and collision checking experience. We have coordinated hundreds of fire suppression projects using 3D software

"Building models and BIM technology will certainly become the standard representation and practice for construction within most of our lifetimes."

Page 8: Vermont India1

We provide complete sets of Material and shop fabrication

drawing which helps in figure-out actual material installed, and

also fitter knows which pipe materials/ pipes need to install

where.

Page 9: Vermont India1

We provide estimated quantity of materials used in the projects, your work is to put the value and labor cost, which saves lots of time of project manager, one can concentrates more to bring projects.

Page 10: Vermont India1

DRAWINGS SETUP WITH GIVEN TITAL BLOCK

START

PLACE STANDPIPE AND RUN BULK AND TAKE APPROVAL

APPROVED

YES

NO

SETUP STPS CALCULATION AND RISER DIAGRAM

SELECT SPRINKLER HEAD AND SEND FOR APPROVAL

FINALIZE PUMP SIZE STP SIZE AND SEND FOR APPROVAL

APPROVED YES

NO

APPROVED

YES

NO

FINISH HEAD AND PIPE LAYOUT AND SEND FOR APPROVAL

FINISH FLOOR CALCULATIONS AND SIZE ALL PIPES

APPROVED YES

NO

APPROVED YES

NO

FINISH PRV CALCULATION IF REQUIRED

FINISH 3D FIRE PUMP DESIGN

APPROVED YES

NO

FINISH GENERAL NOTES DETAIL PAGES AND SITE PLAN. SNED

FOR APPROVAL

S

T

E

P

3

APPROVED YES

NO

STEP 1 STEP 2

FINAL PDF

PRINT

FINAL PDF

PRINT

FINAL PDF

PRINT

STEP

4

COMBINED

AND SUBMITT

Page 11: Vermont India1

STEP 5

STOP

STEP 6

COORDINATION

PIPE LISTING

AS - BUILT

STEP 4

Page 12: Vermont India1