2
RETROFIT PROJECTS Improved ventilation systems using a decentralized approach offer significant health, comfort and energy-saving benefits. • Energy recovery membrane with no cross-over of viruses. • 100% fresh outside air to the building with no recirculation. • Integrated system with heating, cooling and dehumidification. • Better control for airflow zones. • Units are compact and mount to the ceiling or walls. • Minimal ductwork and vertical duct chases. Left: Oxygen8 ceiling-mount ERV retrofit for a classroom application. Ventilation improvements in retrofit projects help to improve the health of the building and reduce the energy demand. These improvements can help to eliminate bulky roof-top HVAC equipment while increasing the indoor air quality in buildings, create space in crowded mechanical rooms and lower operating costs. Office Fit Out | Boston, MA | 2 Nova A16 | 350 cfm Office Retrofit | Boston, MA | Nova C24 | 1500 cfm Restaurant Retrofit | NYC | Nova C24 | 1500 cfm VENTILATION FOR

VENTILATION FOR RETROFIT PROJECTS

  • Upload
    others

  • View
    7

  • Download
    0

Embed Size (px)

Citation preview

Page 1: VENTILATION FOR RETROFIT PROJECTS

RETROFIT PROJECTS

Improved ventilation systems using a decentralized approach offer significant health, comfort and energy-saving benefits.

• Energy recovery membrane with no cross-over of viruses.• 100% fresh outside air to the building with no recirculation.• Integrated system with heating, cooling and dehumidification.• Better control for airflow zones.• Units are compact and mount to the ceiling or walls.• Minimal ductwork and vertical duct chases.

Left: Oxygen8 ceiling-mount ERV retrofit for a classroom application.

Ventilation improvements in retrofit projects help to improve the health of the building and reduce the energy demand. These improvements can help to eliminate bulky roof-top HVAC equipment while increasing the indoor air quality in buildings, create space in crowded mechanical rooms and lower operating costs.

Office Fit Out | Boston, MA | 2 Nova A16 | 350 cfm Office Retrofit | Boston, MA | Nova C24 | 1500 cfm Restaurant Retrofit | NYC | Nova C24 | 1500 cfm

VENTILATION FOR

Page 2: VENTILATION FOR RETROFIT PROJECTS

VentumPremium Efficiency Solution20 - 32" depth

400 ― 3000 cfm

Features Counter-flow Enthalpy Core, ECM Fans, Factory Mounted Controls & BMS Integration

NovaLow Profile Solution16 - 30" depth

400 ― 3500 cfm

Features Cross-flow Enthalpy Core, ECM Fans, Factory Mounted Controls & BMS Integration

NovaOutdoor & High Airflows30 - 69" depth

400 ― 8100 cfm

Features Cross-flow Enthalpy Core, ECM Fans, Factory Mounted Controls & BMS Integration

Oxygen8 Solutions

To see more retrofit project examples and learn about Oxygen8’s solutions and capabilities visit our website at oxygen8.ca

VRV OUTDOOR UNIT

to heat and cool ventilation air

EXPANSION VALVE

for temperature control

DX COILHeats and cools the air, and pairs with the VRV Outdoor Unit

ENERGY RECOVERYThe core of the ERV transfers the indor air heat and humidity to the incoming outside air.

FILTERS

and particles in the air to stop them from entering the building.

FANSThe two fans work to pull fresh air from outside into the building, and push the stale air from inside the building out.

Low-Profile Split Ventilation Systems with Decoupled Coil Modules and VRV Integration

• Low-cost and flexible solution for 100% outside ventilation air.

• Supplemental heating and cooling with Daikin VRV technology.

• Lower energy bills with savings from VRV, heat transfer and energy recovery ventilators.

• Consistent and customizable temperatures.

• Quiet operation with no forced air.

• IAQ monitoring with RiptideIO (CO2, VOC, Relative Humidity and Air Changes per Hour).

Mixed Use Retrofit | Minnesota Nova C24 | 1500 cfm

Office Retrofit | Vancouver, BC Nova C24 | 1800 cfm

University Residence Retrofit | Kelowna, BC Nova C24 & C30 | 8100 cfm