2
Variable Speed Commercial Pump Duty Motor ECM Motor, Control and User Interface www.usmotors.com • Reduce Electricity Use – Up to 82% Efficiency Electronically Commutated Motor (ECM) can provide 70%-90% in electricity savings vs. constant speed pumps. • Simple Installation – Integrated adjustable speed control & motor are factory prewired. Simply connect the power supply. Eliminate the cumbersome wall- mounted drive and its associated programming and wiring issues. • Technology – Manually adjust the motor speed to optimize the system efficiency or allow the system to communicate to the motor control when variable demand is preferred. Rev. 10/14 Simple Manual Speed Control Speed control via Low Voltage Connection Efficiency, Simplicity & Technology Breakthrough USER INTERFACE This graph shows the large increase in energy consumption when running the pump and motor at high speeds. Slowing the pump and motor speed saves significant energy dollars, similar to better automobile gas mileage when driving 40 mph versus 70 mph. Traditional commercial duty pumps run at only one speed and the one speed is high speed. Most pumps are usually oversized for the application and they rely on induction motor technologies which are far less efficient then ECM technology. This results in traditional pumps being energy hogs. ECM technology can save commercial building owners 30% to 90% in energy savings. 40% 50% 60% 70% 80% 90% 400 600 1,000 1,400 1,600 1,800 Typical Efficiency Curve of Motor & Drive RPMs 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 20% 30% 40% 50% 60% 70% 80% 90% 100% Pump Motor Speed vs. Power Consumpon % INPUT POWER % RPM

Variable Speed Commercial Pump Duty Motor

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Variable Speed Commercial Pump Duty Motor

Variable Speed Commercial Pump Duty MotorECM Motor, Control and User Interface

www.usmotors.com

• Reduce Electricity Use – Up to 82% Efficiency Electronically Commutated Motor (ECM) can provide 70%-90% in electricity savings vs. constant speed pumps.

• Simple Installation – Integrated adjustable speed control & motor are factory prewired. Simply connect the power supply. Eliminate the cumbersome wall-mounted drive and its associated programming and wiring issues.

• Technology – Manually adjust the motor speed to optimize the system efficiency or allow the system to communicate to the motor control when variable demand is preferred.

Rev. 10/14

Simple Manual Speed Control

Speed control via Low Voltage Connection

Efficiency, Simplicity & Technology Breakthrough

USER INTERFACE

This graph shows the large increase in energy consumption when running the pump and motor at high speeds. Slowing the pump and motor speed saves significant energy dollars, similar to better automobile gas mileage when driving 40 mph versus 70 mph.

Traditional commercial duty pumps run at only one speed and the one speed is high speed. Most pumps are usually oversized for the application and they rely on induction motor technologies which are far less efficient then ECM technology. This results in traditional pumps being energy hogs. ECM technology can save commercial building owners 30% to 90% in energy savings.

40%

50%

60%

70%

80%

90%

400 600 1,000 1,400 1,600 1,800

Typical Efficiency Curve of Motor & Drive

RPMs

0%10%20%30%40%50%60%70%80%90%

100%

20% 30% 40% 50% 60% 70% 80% 90% 100%

Pump Motor Speed vs. Power Consump�on

% IN

PUT

POW

ER

% RPM

Page 2: Variable Speed Commercial Pump Duty Motor

Variable Speed Commercial Pump Duty Motor ECM Motor, Control and User Interface

8050 W. Florissant Avenue | St. Louis, MO 63136Phone: 888-637-7333 | Fax: 866-422-7758

† All marks shown within this document are properties of their respective owners.

Nidec Motor Corporation, 2014; All Rights Reserved. U.S. MOTORS® is a registered trademark of Nidec Motor Corporation. Nidec Motor Corporation trademarks followed by the ® symbol are registered with the U.S. Patent and Trademark Office.

www.usmotors.com

Dimension Print

Rev. 10/14

Applications

• Hydronic Pumping• Chemical Processing• Filtration Systems• Water Pressure Boosting Systems• Commercial Pumping Applications

Key Features and Benefits

• Variable Speed Pump Motor• No programming required• GFCI Compliant Product• UL and CSA Listing• Allows for: Improved Hydraulic Efficiency Quieter Pump Operation Longer Pump Life Energy Payback in less than 2 Years 3rd party drive to install

Horsepower: 1/3, ½, ¾, 1 HP

Volts: 115 or 230

RPM: 300 to 1800 RPM

Mounting: NEMA® 56C, 56J or Square Flange

On Board Control: Fully Potted Electronics Manual Speed Control or 0-10Vdc Control EMI Compliant regarding Class B Radiated & Conductive Emissions