Variable frequency drive for control and protection of the electric pump

LOGIC SP-STP-TPMade in Italy

2

It varies the number of motor revolutions of the electric pump depending on the water withdrawn by the system in order to maintain constant pressure and flow.

Can be installed on surface and submersible pumps.

Easy to install, set and adjust.

Allows to regulate the system pressure and the cut-in pump pressure.

Protects the pump from dry running.

Ensures energy savings.

Comes with built-in accumulator.

No need for expansion tank, check valve, filter and fittings.

Reduces the effects of water hammer.

Maintenance-free.

www.trevipumpcontrols.com.au www.trevipumpcontrols.co.nz

Page 3: Variable frequency drive for - Bluewater Tanks · Variable frequency drive for control and protection of the electric pump LOGIC SP-STP-TP Made in Italy 2 It varies the number of

Control and adjustment panel

SIGNALLING OF THE PHASES AND ANY MALFUNCTIONING

Power On (green Led on) Power onPump On (yellow Led on) Pump onFailure (red Led blinking) Pump stopped due to water shortage or malfunctioning. The malfunctioning code will remain lit up on the “CURRENT” display until the device is reset. (Example: H1 water shortage on suction)Restart Press the red button to restart the device in case of a pump stop.

SETTING THE VALUE OF THE CURRENT ABSORBED BY THE MOTOR

Read the value of the current in amperes indicated on the pump motor nameplate, press the A button (green Led on) and set the value on the display using the buttons -/+ (0.5 A steps). After entering the value, press the A button again (yellow Led on) to lock the setting. When the pump is working the real value of the motor input will appear on the display.

MANOMETER: The real value of the system pressure will appear on the display.

SWITCH: Press the green ON button (green Led on) to start the pump and the red OFF button to turn it off (red Led on).

IDENTIFICATION: Specific serial number and data matrix of the device.

SETTING THE VALUE OF THE SYSTEM PRESSURE

Press the P button (green Led on) and set the value on the display using the – / + buttons (0.5 bar steps).After setting the desired value, press the P button again (red Led on) to lock the adjustment set.

SETTING THE RESTART VALUE OF THE PUMP

Press the P button (green Led on) and set the value on the display using the - / + buttons (0.1 bar steps).After setting the desired value, press the P button again (red Led on) to lock the adjustment set.

3www.trevipumpcontrols.com.au www.trevipumpcontrols.co.nz

Page 4: Variable frequency drive for - Bluewater Tanks · Variable frequency drive for control and protection of the electric pump LOGIC SP-STP-TP Made in Italy 2 It varies the number of

SERIES LOGIC SP-STP-TP: Models and technical features

H07 RN-F 3G 1.5 mm2 L 1.5 m Australian plug

H07 RN-F 3G 1.5 mm2 L 0.5 m Australian socket

260 x 312 x 285 mm ~ 5 Kg

1.3 kW - 1.7 HP 1.5 kW - 2 HP 2.2 kW - 3 HP

Communication between devices Available on request

VOLTAGE / MOTOR

MODELS

Mains Voltage

SP 8.5

Acceptable voltage fluctuations

Frequency (automatic recognition)

Motor frequency 140 Hz

Single-phase pump motor voltage

Three-phase pump motor voltage

Maximum pump motor current

Maximum pump motor power

Soft engine start

Cable for connection to mains

Cable for connection to the motor

Motor cable length up to 80 m.

Maximum operating pressure

Adjustable system pressure

Adjustable cut in pressure

Minimum flow

Maximum working temperature

Protection degree

Digital manometer

Digital ammeter

Dry run protection

Timed automatic rearming

Anti-jamming function

Protection fuse

Short-circuit protection between phases

Short-circuit protection between phases and earth

Amperometric protection

Protection against power surges

Over-temperature protection

Pressure sensor fault detection

Removable pressure sensor

Remote ON/OFF connection

Float switch and level probe connections

Remote alarm connection

Accumulation

Check Valve

Water discharge

Male connections

Interchangeable male connections

Stainless steel screws

Overall dimensions and weight

SINGLE-PHASE/SINGLE-PHASE

seYseYseY

seYseYseY

seYseYseY

seYseYseY

seYseYseY

seYseYseY

seYseYseY

seYseYseY

seYseYseY

seYseYseY

seYseYseY

seYseYseY

seYseYseY

seYseYseY

Yes - Spare part available on request

seYseYseY

seYseYseY

seYseYseY

Incorporated Incorporated Incorporated

Incorporated Incorporated Incorporated

seYseYseY

seYseYseY

8.5 A

1 1 1

1 1 1

1 1/4 - 1 1/4 1 1/2 - 1 1/2 1 1/2 - 1 1/2

1 1/4 - 1 1/4 1 1/4 - 1 1/4

4 www.trevipumpcontrols.com.au www.trevipumpcontrols.co.nz

Page 5: Variable frequency drive for - Bluewater Tanks · Variable frequency drive for control and protection of the electric pump LOGIC SP-STP-TP Made in Italy 2 It varies the number of

SERIES LOGIC SP-STP-TP: Models and technical features

Communication between devices

VOLTAGE / MOTOR

MODELS

Mains Voltage

Acceptable voltage fluctuations

Frequency (automatic recognition)

Motor frequency 140 Hz

Single-phase pump motor voltage

Three-phase pump motor voltage

Maximum pump motor current

Maximum pump motor power

Soft engine start

Cable for connection to mains

Cable for connection to the motor

Motor cable length up to 80 m.

Maximum operating pressure

Adjustable system pressure

Adjustable cut in pressure

Minimum flow

Maximum working temperature

Protection degree

Digital manometer

Digital ammeter

Dry run protection

Timed automatic rearming

Anti-jamming function

Protection fuse

Short-circuit protection between phases

Short-circuit protection between phases and earth

Amperometric protection

Protection against power surges

Over-temperature protection

Pressure sensor fault detection

Removable pressure sensor

Remote ON/OFF connection

Float switch and level probe connections

Remote alarm connection

Accumulation

Check Valve

Water discharge

Male connections

Interchangeable male connections

Stainless steel screws

Overall dimensions and weight

H07 RN-F 4G 2.5 mm2 L 1.5 m

H07 RN-F 4G 2.5 mm2 L 1 m

15 A

TP 15TP 8.5

260 x 312 x 320 mm ~ 6 Kg

400 Vac 400 Vac

400 Vac 400 Vac

3 kW - 4 HP 5.5 kW - 7.5 HP

8.5 A

Available on request

THREE-PHASE/THREE-PHASE

Available on request

Yes Yes

Yes Yes

Yes Yes

Yes Yes

Yes Yes

Yes Yes

Yes Yes

Yes Yes

Yes Yes

Yes Yes

Yes Yes

Yes Yes

Yes Yes

Yes Yes

Yes - Spare part available on request

Yes Yes

Yes Yes

Yes Yes

Incorporated Incorporated

Incorporated Incorporated

Yes Yes

Yes Yes

H07 RN-F 3G 1.5 mm2 L 1.5 m Australian plug

H07 RN-F 4G 1.5 mm2 L 1 m

260 x 312 x 285 mm ~ 5 Kg

1.9 kW - 2.5 HP 2.2 kW - 3 HP

Available on request

SINGLE-PHASE/THREE-PHASE

Available on request

Yes Yes

Yes Yes

Yes Yes

Yes Yes

Yes Yes

Yes Yes

Yes Yes

Yes Yes

Yes Yes

Yes Yes

Yes Yes

Yes Yes

Yes Yes

Yes Yes

Yes Yes

Yes Yes

Yes Yes

Incorporated Incorporated

Incorporated Incorporated

Yes Yes

Yes Yes

Yes - Spare part available on request

STP 8.5

8.5 A 11 A

1

3 33 3

1 1 1

1 - 1 1 1/4 - 1 1/4

1 1/4 - 1 1/4

1 1/4 - 1 1/4 1 1/4 - 1 1/4

1 1/2 - 1 1/2 1 1/2 - 1 1/21 1/2 - 1 1/2

5www.trevipumpcontrols.com.au www.trevipumpcontrols.co.nz

Page 6: Variable frequency drive for - Bluewater Tanks · Variable frequency drive for control and protection of the electric pump LOGIC SP-STP-TP Made in Italy 2 It varies the number of

Installation

Operation

It is possible to replace the connections (supplied as spare-parts and included in the package) on the inlet and/or outlet of the device, depending on the system requirements, without compromising its operation.Mount the device in a vertical position directly onto the pump or between the pump and the first tap.While not necessary to install a ball valve between the device and the system, this makes it possible to identify whether any anomalies derive from the device or the system.Carry out the electrical wiring and energize.On the panel, the green “Power On” Led and the red “Off” Led light up and blinking dashes appear on all the displays while the device performs the setup.At the end of the setup, the current values and the pressure set in the factory will appear (CURRENT 1.5 A- SYSTEM PRESSURE 3.0 Bar – CUT-IN PRESSURE 1.5 bar) and the “CURRENT” display will start blinking.Now set the first current value absorbed by the motor as indicated on its nameplate.To adapt the system to the desired operation, it may be necessary to change the factory-set values: system pressure 3 bar- cut-in pressure 1.5 bar.The set pressure value of the system must be less than the maximum effective pressure generated by the pump and compatible with the desired pump delivery.The set cut-in pressure value must be less than the maximum effective pressure generated by the pump and higher than the pressure delivered by the height of water column exerted on the device.

EXAMPLE OF SETTING PARAMETERSCurrentAdjustment step 0.5A up to 10A – 1 A above 10 ASet the value immediately after the value indicated on the nameplate.Example: motor absorption (nameplate data) 6.3 A ! max. 6.5 A

System pressureAdjustment step 0.5 bar.Set the desired value provided it is lower than the maximum effective pressuregenerated by the pump.Example: maximum pump pressure 9 bar ! max. 8 bar

Cut-in pressureAdjustment step 0.1 bar.Set the desired value provided it is higher (~ 0.5 bar) than the pressure generatedby the water column.Example: water column pressure 1 bar ! min. 1.5 bar.

After setting the values press the green “ON” button on the switch (green Led lit up) to turn on. The set pressure values can also be changed while the pump is operating.

The device varies the number of motor revolutions of the electric pump depending on the water withdrawn by the system in order to maintain a constant delivery and pressure, provided compatible with the characteristics of the relative electric pump and the system.

• In case of malfunctioning, the device will stop the pump, the red “Failure” Led will start blinking on the panel and the respective code will ap-pear on the “CURRENT” display. Example: H1 incoming water shortage.

• In case of failure, the pressure sensor (available on request as spare-parts) can be easily replaced even by the user without removing the device from the system.

• In case of a pump stop due to an input water shortage, the device will automatically make 6 double attempts to rearm the pump, according to a tredetermined sequence to allow the system to reload after the pump stop. After the last failed attempt to rearm, the device will remain permanently in “Failure” status (blinking red Led) pending manual rearming by pressing the red “Restart” button.

The user can rearm the device at all times by pressing the red “Restart” button.• If the pump remains stopped for 24 consecutive hours for any reason, the device will carry out a start up of the pump motor of approximately

5 seconds (anti-jamming function).• In case of blackout, the device will automatically rearm once the electricity returns.• The device is designed for the connection of a command and / or an alarm (light and siren) remote, a float switch and / or a level probe.

The device can be fitted on request of additional keyboard to access to the serial output RS 485 to allow communication between two or more devices of the Logic series and a device with a control panel if enabled for communication.

6 www.trevipumpcontrols.com.au www.trevipumpcontrols.co.nz

Page 7: Variable frequency drive for - Bluewater Tanks · Variable frequency drive for control and protection of the electric pump LOGIC SP-STP-TP Made in Italy 2 It varies the number of

Electronic FlowswitchStarts and stops the pump and protects it from dry running

Logicflow is also available in the “Special” version equipped with automatic restarts.

LOGICFLOWMade in Italy

The device must be mounted in a vertical position. In order to operate, the flowswitch requires a minimum flow that passes through it when a tap of the system is opened. For this reason the device and the system tap must be installed underneath the tank (Fig. 1 - Fig. 2). It stops and starts the pump depending on the opening and closing of the system taps. It stops the motor and saves the pump in the case of a water shortage. To restore normal operation to the device and the system simply press the red “Restart” button. In case of a blackout, it will automatically rearm again several seconds after the electricity returns.

Operation

Technical features Control Panel

Overall dimensions

Fig. 1

Fig. 2

In case of direct suction from water mains, a minimum pressure (0.02 bar) allows the LOGICFLOW to start the pump.

Single-phase mains voltage 230 Vac Maximum operating pressure 16 bar

Acceptable voltage fluctuations +/- 10% Minimum flow 0,5 l/min

Frequency 50 - 60 Hz Maximum Operating temperature

60°C

Maximum pump motor current 8 A Protection degree IP 65

Maximum pump motor power 1,1 kW (1,5 HP) Male connections 1”

Power on Green LED on Power on

Pump on Yellow LED on Pump on

Restart Red button Resets the device and thesystem in case of failure

On request Logicflow can be supplied with cables.

7www.trevipumpcontrols.com.au www.trevipumpcontrols.co.nz

Page 8: Variable frequency drive for - Bluewater Tanks · Variable frequency drive for control and protection of the electric pump LOGIC SP-STP-TP Made in Italy 2 It varies the number of

Electronic Motor-SaverStops the motor and protects the pump in case of water shortage and overcurrent.

LOGICSTOPMade in Italy

In order to operate, the electrical power supply of the pump must be connected to the mains. For this reason the power supply plug of the pump must be inserted in the socket of the device which is in turn connected to the power point (Fig. 1). In case of a water shortage on suction, the device will stop the pump and protect it against dry running. This malfunctioning is indicated with the red “Failure” Led lit up. In case of the current absorption exceeding 8 amperes, the device will stop the pump motor and protect it against over-current. This malfunctioning is indicated with the red “Failure” Led lit up. To restore normal operation to the device and the system simply press the red “Restart” button. In case of a blackout, it will automatically rearm again several seconds after the electricity returns.

Operation

Technical features Control Panel

Overall dimensions

Single-phase mains voltage 230 Vac Pump motor current Min 3 A - Max 8 A

Acceptable voltage fluctuations +/- 10% Operating temperature Min 5ºC - Max 45ºC

Frequency 50 Hz Maximum ambient temperature

55°C

Electrical Connectionsto the cable of pump motor

(Australian socket incorporated)

Electrical Connectionsto the power point

(Australian plug incorporated)

Power on Green LED on Power onPump on Yellow LED on Pump on

Failure Red LED blinking Water shortageFailure Red LED on OvercurrentRestart Red button Acquisition of motor data

Reset in case of failure