eco hometec

Variable Controlled Output (VCO) Solar Compatible jjjjj

Gas Condensing Boilers EC 16, 23, 31 and 38kW

IINNSSTTAALLLLAATTIIOONN && UUSSEERR IINNSSTTRRUUCCTTIIOONNSS

PLEASE LEAVE WITH THE END USER

Page 2: Variable Controlled Output (VCO) Solar Compatible jjjjj ...boilermanuals.org.uk/boilers/Eco Hometec/EC16,22,31... · eco hometec Unit 11E Carcroft Enterprise Park Carcroft Doncaster

eco hometec Unit 11E Carcroft Enterprise Park Carcroft Doncaster DN6 8DD Tel. 01302 722266 Fax. 01302 728634 e.mail. [email protected] http://www.eco-hometec.co.uk D:\MAY_2001_All_Manuals\1538INST.DOC\30 June 2002 eco hometec has a policy of continuous improvement and reserves the right to change any specification without notice. Your statutory rights are not affected. eco hometec is committed to design, develop and produce environmentally friendly appliances for both domestic and commercial applications

Page 2 eco hometec (uk) ltd.

Page 3: Variable Controlled Output (VCO) Solar Compatible jjjjj ...boilermanuals.org.uk/boilers/Eco Hometec/EC16,22,31... · eco hometec Unit 11E Carcroft Enterprise Park Carcroft Doncaster

Contents 1. Why choose eco hometec? ....................... 6

2. Safety Considerations ............................... 7

3. Symbols..................................................... 7 3.1 Gas Safety................................................7

4. Electrical Supply ........................................ 7

5. Terms of Warranty..................................... 8

6. Commissioning Certificate......................... 8 6.1 Requirements for the system quality .......8

7. Existing Installations.................................. 8 7.1 Considerations prior to Connection. .........8 7.2 Expansion Vessels ...................................9

8. Introduction................................................ 9 8.1 Variable Controlled Output .......................9 8.2 Emissions. ................................................9 8.3 PPS Plastic Flue System..........................9 8.4 Approvals .................................................9 8.5 Additional Features...................................9

9. Description of Appliances........................ 10 9.1 EC 16,23,31 and 38 H ............................10 9.2 EC 16,23,31 and 38 HS..........................10 9.3 EC 16,23,31 and 38 S ............................10

10. Technical Information .............................. 11

11. Main Component Specification................ 13 11.1 Head Height of the Central Heating Circuit. 13 11.2 Air Fan Details. .......................................13 11.3 Gas Control Valve. .................................13

12. Unpacking & Items Supplied ................... 14

13. Accessories ............................................. 14

14. Operation................................................. 15 14.1 Variable Controlled Output .....................15 14.2 Variable pump ........................................15 14.3 Frost Protection ......................................15 14.4 Year Long Protection..............................15

15. Siting the Appliance................................. 15 15.1 Timber Framed Dwellings.......................16

16. Hydraulic Connections ........................... 16 16.1 First Fixing Pipe-work .............................16 16.2 Type ‘H’ Connections .............................16 16.3 Type ’HS’ Connections. ..........................16 16.4 ‘S’ Connections. .....................................17 16.5 Clearances .............................................17 16.6 Checks Before Siting ..............................17 16.7 Fixing the boiler. .....................................17 16.8 Removing The Casing ............................17

17. Flues and Ventilation............................... 18

17.1 Maximum Flue Lengths ..........................18 17.2 Available Flue Components....................20 17.3 Pluming ..................................................21 17.4 Condensate in the Flue ..........................21 17.5 Flueing Options ......................................21 17.6 Installing a Concentric Flue ....................21 17.7 Vertical flue Installations.........................23 17.8 Modular Installations...............................23 17.9 Fan Flued Terminal Positions .................26

18. Gas Supply...............................................26 18.1 Gas Supply .............................................26 18.2 LPG Gas Supply.....................................27 18.3 Setting The Gas Type.............................27 18.4 Conversion to LPG .................................27

19. Air Supply .................................................28 19.1 Concentric Flue ......................................28 19.2 Conventionally Flue ................................28 19.3 Compartment Ventilation ........................28

20. Hydraulic Requirements...........................29 20.1 Expansion Vessel ...................................29 20.2 Hydraulic Resistance..............................30 20.3 Condensate Drain...................................30 20.4 System By-Pass .....................................30

21. Electrical Connections..............................33

22. Heating Control Options...........................33 22.1 240 Volt Connections .............................33 22.2 Low Voltage Connections.......................34 22.3 Built-in clock ...........................................34

23. Boiler Control panel..................................34

24. Boiler Control Panel .................................35 24.1 System water pressure gauge................35 24.2 On / off switch.........................................35 24.3 Lcd control display..................................35 24.4 Menu - reset button ................................35 24.5 Summer winter button ............................35 24.6 Engineers button ....................................35 24.7 Test button..............................................36 24.8 General...................................................36

25. Menu options............................................36 25.1 Party .......................................................36

26. User programming ...................................36 26.1 Hot Water Temperature..........................36 26.2 Day temperature function .......................36 26.3 Time/day function ...................................36 26.4 Setting the ch timer.................................36 26.5 Setting the HW timer ..............................38 26.6 Setting MR03 times ................................38 26.7 Night-time lower 0oc. ..............................38 26.8 Holiday function ......................................38 26.9 Installer ...................................................38

27. Installer Programming ..............................39

28. Outside Temperature Control...................40 28.1 Flow Temperature at + 20°C ..................40 28.2 Outside Temp. Control at - 1°C ..............41

EC 16~38 Installation Manual page 3

Page 4: Variable Controlled Output (VCO) Solar Compatible jjjjj ...boilermanuals.org.uk/boilers/Eco Hometec/EC16,22,31... · eco hometec Unit 11E Carcroft Enterprise Park Carcroft Doncaster

28.3 Minimum pump speed ............................41 28.4 Maximum pump speed ...........................41 28.5 Flow temperature secondary circuit........41 28.6 Service counter ......................................41 28.7 Pump continuous....................................41 28.8 Eco/eco+ ................................................41 28.9 Post running of pump after HW ..............41 28.10 Post running of pump after CH...............41 28.11 Minimum DHW Capacity ........................42 28.12 Maximum DHW Capacity .......................42 28.13 Maximum CH capacity ...........................42 28.14 Function Setting .....................................43

29. Commissioning ........................................47 29.1 Electrical Checks....................................47 29.2 Gas Supply.............................................47 29.3 Connection to Pipe-work ........................47 29.4 Water Treatment ....................................47 29.5 Flushing System Pipe-work ....................47 29.6 Filling and Venting the System...............47

30. Combustion Ratio ....................................48 30.1 Commissioning NG and LPG .................48

31. Setting the Maximum CO2 Value .............48 31.1 Flue System Check ................................49 31.2 STB Test Button (Green)........................49

32. Diagnostics ..............................................49 32.1 Control panel ..........................................49

33. Fault Finding. ...........................................50

34. Handing the boiler over............................54 34.1 Customer Familiarisation........................54

35. Annual Servicing.....................................54 35.1 Service Inspection ..................................54 35.2 Pre-preventative Maintenance................55 35.3 Service records ......................................55

36. Decommissioning the boiler.....................55

37. User Instructions......................................56 37.1 Annual Servicing. ..................................56 37.2 Decommissioning the boiler. ..................56 37.3 Built-in clock ...........................................56 37.4 Boiler Control Panel ...............................57 37.5 System water pressure...........................57 37.6 On / off switch.........................................57 37.7 Lcd control display..................................57 37.8 Menu - reset button ................................57 37.9 Summer winter button ............................57 37.10 Engineers button ....................................57 37.11 Test button .............................................57 37.12 General ..................................................57

38. Programming Menu options.....................58 38.1 Party.......................................................58 38.2 Hot Water Temperature..........................58 38.3 Day temperature function .......................58 38.4 Time/day function ...................................58 38.5 Setting the ch timer ................................58 38.6 Setting the hw timer................................59 38.7 Setting MR03 times ................................60 38.8 Night-time lower 0oc ...............................60

38.9 Holiday function......................................60 38.10 Installer...................................................60

Figure 1 Overall Dimensions mm. ....................12 Figure 2 Bottom View Dimensions mm. ...........12 Figure 3 Top View Dimensions mm .................13 Figure 4 Pump Head Height.............................13 Figure 5 Air Fan Curve.....................................13 Figure 6 Gas Valve ..........................................13 Figure 7 Pipe-work Layouts ............................16 Figure 8 Minimum Clearances .........................17 Figure 9 Removing the Casing.........................17 Figure 10 Fixing Dimensions..............................18 Figure 11 Flue Design........................................19 Figure 12 Thermal Lift ........................................20 Figure 13 Flue Preparation ................................21 Figure 14 Dimensions for cutting flue hole .........22 Figure 15 Wall Terminal .....................................22 Figure 16 Vertical Wall Terminal ........................23 Figure 17 Vertical Flue Application.....................23 Figure 18 Modular Installation............................23 Figure 19 Vertical Roof Terminals......................24 Figure 20 Concentric flue fittings........................25 Figure 21 Concentric 80mm adaptor..................25 Figure 22 80mm Flue Tubes ..............................25 Figure 23 Fan Flued Terminal Positions ............26 Figure 24 H Type Hydraulic system design........31 Figure 25 HS Type Hydraulic system design .....31 Figure 26 S Type Combi Hydraulic system design

32 Figure 27 Electrical Connections........................32 Figure 28 Connecting to the Mains ....................33 Figure 29 Boiler Control panel ...........................34 Figure 30 Weather Compensation .....................40 Figure 31 O/T Ctrl Flow temp 85oC. ...................40 Figure 32 O/T Ctrl Flow temp 70oC ....................40 Figure 33 O/T Ctrl Flow temp 50oC ....................40 Figure 34 Internal Wiring....................................46 Figure 35 Gas valve adjustments.......................49 Figure 36 Boiler Control panel ...........................56 Table 1 Dimensions & Connections ....................11 Table 2 Heating Specifications............................11 Table 3 Capacities & Weights .............................11 Table 4 Hot Water Specifications ........................12 Table 5 Connection Values .................................12 Table 6 Minimum Clearances..............................17 Table 7 Flue Resistance......................................19 Table 8 Flue Terminal Positions. .........................26 Table 9 Ventilation...............................................28 Table 10 Expansion Vessel Req. ......................29 Table 11 System Contents................................30 Table 12 Programming Functions .....................39 Table 13 Installer Functions..............................39 Table 14 Minimum & Maximum fan speeds ......48 Table 15 CO2

Outputs ......................................49 Table 16 LCD Display ‘NON FLASHING’ .........50 Table 17 LCD ‘NON FLASHING’ burner off .....50 Table 18 Fault Display FLASHING ...................51 Table 19 Non Display Faults and Errors ...........51 Table 20 Reasons For Error Display.................52

Page 4 eco hometec (uk) ltd.

Page 5: Variable Controlled Output (VCO) Solar Compatible jjjjj ...boilermanuals.org.uk/boilers/Eco Hometec/EC16,22,31... · eco hometec Unit 11E Carcroft Enterprise Park Carcroft Doncaster

HEALTH & SAFETY INFORMATION FOR THE INSTALLER AND SERVICE

ENGINEER

Under the current issue of the Consumer Protection Act and the Health and Safety at Work Act it is a requirement to provide information on substances hazardous to health (COSSH Regulations). eco hometec takes every reasonable care to ensure that these products are designed and constructed to meet these general safety requirements, when properly used and installed. To fulfil this requirement each boiler is comprehensively tested before despatch. When working on the appliance it is the Users/Installers responsibility to ensure that any necessary personal protective clothing or equipment is worn appropriate to parts that could be considered as being hazardous to health and Safety. This appliance may contain some of the items below. INSULATION AND SEALS Glass Rope, Mineral Wool, Insulation Pads, Ceramic Fibre, Glass Insulation. may be harmful if inhaled may be irritating to the skin, eyes, nose or throat When handling avoid inhalation and contact with eyes. Use (disposable) gloves, face masks and eye protection. After handling, wash hands and other exposed parts. When disposing, reduce dust with water spray, ensure parts are securely wrapped. GLUES, SEALANTS & PAINT Glues, Sealant and Paints used in the product present no known hazards when used in the manner for which they are intended.

EC 16~38 Installation Manual page 5

Page 6: Variable Controlled Output (VCO) Solar Compatible jjjjj ...boilermanuals.org.uk/boilers/Eco Hometec/EC16,22,31... · eco hometec Unit 11E Carcroft Enterprise Park Carcroft Doncaster

1. Why choose eco hometec? Features and Benefits at a glance

Wall mounted ultra high efficiency gas boilers

Suitable for installation into existing systems, new radiator and/or underfloor installations, can also be used with solar heating systems

Emissions levels are 90% lower than the “Blue Angel” standards and significantly less than the levels specified in the “Swiss Clean Air Act” and the “Hamburg Development Program" the World’s most stringent regulations. (NOx 20mg\kWh CO 14mg\kWh)

Long life Austenitic stainless steel heat exchanger

Energy saving modulating fan

Energy saving modulating burner

Energy saving modulating pump

Energy saving modulating system water temperature

Plug in components for fast and cost effective servicing

Corrosion free PPS plastic flue tubes and fittings offering ease of siting

Data logging via PC for analysing, performance, operating times, temperatures and for fine-tuning

Built in digital Weather Compensating comfort controller

Built in digital central heating and hot water time clock controller

HS specification with dual flow temperatures for under floor heating systems

The most complete energy efficient home heating appliance available

Guarantee periods Heat Exchanger 5 years other components 2 years

Free help with technical, design and installation issues

Page 6 eco hometec (uk) ltd.

Page 7: Variable Controlled Output (VCO) Solar Compatible jjjjj ...boilermanuals.org.uk/boilers/Eco Hometec/EC16,22,31... · eco hometec Unit 11E Carcroft Enterprise Park Carcroft Doncaster

2. Safety Considerations The installation of this appliance must be carried out by a competent person in accordance with the relevant Gas Safety Regulations (as amended), Building Regulations, Model Water Bylaws and the Building Standards (Scotland) Regulations. eco hometec shall not be responsible for any damage or loss resulting from failure to carefully observe the instructions given. The boiler, except for commissioning purposes, should not be left operating without the casing being attached and firmly secured 3. Symbols In this manual the following symbols are used. This symbol is used to indicate points that are important, to ensure compliance with safety regulations or to facilitate installation or operation.

This symbol ! is used to highlight points that must be observed for the safety of yourself and others. 3.1 Gas Safety

All gas appliances must, by law, be installed by competent persons, e.g. members of CORGI, in accordance with the Gas Safety Regulations. Failure to install appliances correctly could lead to prosecution

!It is in your own interest and that of safety to ensure that the law is complied with. Installer training courses are available for CORGI registered installers. Please contact eco hometec for more information. This installation manual contains all the necessary information required to install and commission the EC VCO 16, 23, 31 and 38kW range of boilers. Please read this manual thoroughly before commencing installation. The installation must be carried out in accordance with the manual otherwise the warranty will be void.

Use only original parts for service and maintenance. After installation ensure the manual is kept close to the boiler and available for reference purposes. The installation should also be in accordance with current editions and comply with the recommendations of the following British Standard Codes of Practice. CP.331.3 Low pressure installation pipes. BS.6798 Boilers of rated output not exceeding 60kW. BS.5546 Installation of gas hot water supplies for domestic purposes. BS. 5449.1 Forced circulation hot water systems. BS.5440.1 Flues (for gas appliances of rated input not exceeding 60kW). BS.5440.2 Air supply (for gas appliances of rated input not exceeding 60kW). 4. Electrical Supply The wiring must comply with the current I.E.E. Wiring Regulations. The Health and Safety Document No. 635 and the Electricity at Work Regulations 1989 must be followed where applicable. The boilers are supplied for 230V +10/-15% 50Hz operation. The method of connection to the mains electrical supply MUST facilitate complete electrical isolation of the boiler. This may be achieved using a readily accessible 3 amp fused double pole switch clearly labelled.

THESE APPLIANCES MUST BE EARTHED.

IMPORTANT This boiler is an EC Certified Appliance and must not be modified or installed in any way contrary to these ‘Installation and Servicing Instructions’.

EC 16~38 Installation Manual page 7

Page 8: Variable Controlled Output (VCO) Solar Compatible jjjjj ...boilermanuals.org.uk/boilers/Eco Hometec/EC16,22,31... · eco hometec Unit 11E Carcroft Enterprise Park Carcroft Doncaster

The manufacturers instructions must NOT be taken in any way as over-riding statutory obligations. 5. Terms of Warranty Damages to the appliance resulting from the following causes will invalidate the warranty: incorrect or unsuitable use of the boiler Please ring the eco hometec technical department for advice on suitability faulty installation or servicing by the purchaser or third parties normal wear and tear failure to maintain or service appliance in compliance with this manual in the case of chemical, electrochemical or electric influences in as much as the fault cannot be attributed to the manufacturer failure to observe installation and/or operating instructions effects of fitting, servicing or repairing parts with non-genuine origin parts (e.g. non-genuine boiler circuit control) damage as a result of dust or other foreign matter being sucked into the burner influence of noxious vapours installation and operation in inappropriate rooms (e.g. in washrooms, launderettes, swimming pools or hobby rooms) continued use when apparatus is defective or requires servicing in the case of inappropriate alterations or renovation work by the purchaser or by third parties oxygen corrosion, particularly when not using diffusion-tight plastic pipes in floor heating systems corrosion as a result of inadequate system water treatment. interim building conditions with unregulated heating operation (manual operation without boiler protection) interim building conditions with dust-polluted combustion air 6. Commissioning Certificate The warranty is only recognised if a completed commissioning certificate (operational test form) is at hand (send in by fax or post), as well as an acknowledgement by eco hometec (u.k.) ltd.

6.1 Requirements for the system quality

Before commissioning the appliance it is essential to clean the installation in accordance with BS 7593: 1992 Installation of in-line strainers is obligatory. As a protection from corrosion and impurities the water additive Fernox MB1 has to be used and maintained (4%). 7. Existing Installations 7.1 Considerations prior to Connection.

IMPORTANT All eco hometec boilers are low water content units. In order to protect and prolong the working life of the appliance, it is important the general condition of older systems is carefully considered. When connecting to an existing installation it is important that system deposits are removed and are not allowed to contaminate boiler. This involves the application of a cleanser and allowing it to circulate around the whole system for a specified time, then flushing to drain.

Consider high pressure flushing to remove all debris in badly contaminated systems. It is important to select the cleanser appropriate to the installation i.e. for a new installation, or for an existing installation. It is good practice to clean the system prior to the installation of the new boiler. The removal of debris, flux residue, grease, metal swarf etc. from new systems and any black magnetic iron oxide sludge and lime scale from old systems is essential.

In-line strainers must be fitted to the return water connections for full protection. All installations must be treated with Fernox MB1 at a concentration of 4%.

Page 8 eco hometec (uk) ltd.

Page 9: Variable Controlled Output (VCO) Solar Compatible jjjjj ...boilermanuals.org.uk/boilers/Eco Hometec/EC16,22,31... · eco hometec Unit 11E Carcroft Enterprise Park Carcroft Doncaster

If plastic pipes are used to connect the boiler to radiators or under floor heating, it is essential that only those types of plastic pipe that incorporate an oxygen diffusion barrier be used. If such pipes are not used, the eco hometec guarantee will become null and void. 7.2 Expansion Vessels

The EC VCO models are designed for connection to a fully pumped sealed heating circuit only. Depending on specification chosen the appliance may be fitted with a 10 litre expansion vessel An additional suitable sized expansion vessel may be required to accommodate volume change (expansion of water) when heated up to maximum operational temperature on larger capacity systems. Select an expansion vessel that matches the volume of the CH system and the static pressure. Expansion vessels should be connected to the system at a point close to the pump inlet in order to maintain positive pressure throughout the system. Installation should comply with BS7074 part 1 and BS5449. 8. Introduction The boiler features the very latest in technology. Developed around an innovative back panel the boiler uses laser welded waterways to interconnect the boilers main components. To facilitate ease of servicing the high grade austenitic stainless steel coiled heat exchanger and other major components are simply plugged into the panel. The boilers incorporate the unique eco hometec premixing, fully modulating, radiant gas burner, 3 bar pressure relief valve, manometer and circulating pump. 8.1 Variable Controlled Output

Unlike most boilers that simply switch on and off the boiler incorporates an integral compensating and modulating digital

controller that automatically adjusts the boilers output depending on system load requirements. This feature, Variable Controlled Output, (VCO) is the very latest from eco hometec in condensing technology and ensures the boiler maintains optimum efficiencies even when operating at part load. 8.2 Emissions.

A further benefit of this very accurate combustion process is the dramatic reduction of the harmful emissions NOx and CO. The emissions exceed the “BlueAngel” standards by more than 90% and are also significantly less than the standards specified in the “Swiss Clean Air Act” and the “Hamburg Development Program" the World’s most stringent regulations. (NOx 20mg\kWh CO 14mg\kWh). 8.3 PPS Plastic Flue System

Due to the extremely low temperature flue gases the boiler may be flued using the lightweight and corrosion resistant eco hometec PPS plastic flue system. 8.4 Approvals

The unit has been approved according to the European standards (CE) and the requirements for cleaner combustion (RAL UZ61) 8.5 Additional Features

A unique SPIRANOX corrosion resistant stainless steel condensate heat exchanger. Integral sensors (PTC) for monitoring flow and return water temperatures. 3 way switching valve and facilities for connection to an eco hometec DHW storage module or similar. Computer controlled combustion analysis with built in fault diagnosis facility. These readings can be down loaded onto a PC by using the RS 2323 interface cable and software available from eco hometec.

EC 16~38 Installation Manual page 9

Page 10: Variable Controlled Output (VCO) Solar Compatible jjjjj ...boilermanuals.org.uk/boilers/Eco Hometec/EC16,22,31... · eco hometec Unit 11E Carcroft Enterprise Park Carcroft Doncaster

9. Description of Appliances 9.1 EC 16,23,31 and 38 H

The ‘H’ model is suitable for a central heating system with hot water output controlled using a 3 way divertor valve (spring return to heating). The appliance produces a low temperature output for under-floor heating or a fixed/variable temperature output for connection to radiators. Flow temperature to hot water cylinder can be set as required (max. 85OC) Hot water cylinders must be double feed indirect and to aid efficiency and fast recovery times (all appliances are hot water priority) should be of the high recovery type. Recommended minimum coil capacity 25kW. The unit has a variable capacity of 20 to 100%, while the maximum capacity can be set and adapted to the capacity of the CH system. 9.2 EC 16,23,31 and 38 HS

The ‘HS’ range are higher specification. With its 4 x 22mm connections it offers a low temperature output, typically 55OC, for under-floor heating or a fixed/variable temperature output for connection to radiators.

Dsspite the low boiler flow temperatures feature ALL low temperature under floor installations require an obligatory mixing valve installing as part of the system controls. Flow temperature to hot water cylinder can be set as required (max. 85OC) The unit has a variable capacity of 20 to 100%, while the maximum capacity can be set and adapted to the capacity of the CH system. Hot water cylinders must be double feed indirect and to aid efficiency and fast recovery times (all appliances are hot water priority) should be of the high recovery type.

Recommended minimum coil capacity 25kW. 9.3 EC 16,23,31 and 38 S

This unit has a built-in heat primary heat exchanger and Hot water production is continuous. The unit has a variable capacity of 20 to 100%, while the maximum capacity can be set and adapted to the capacity of the CH system. EC38S Combi with integral 10Litre store This appliance requires an expansion vessel and a 3 bar pressure relied valve fitting to the system

Page 10 eco hometec (uk) ltd.

Page 11: Variable Controlled Output (VCO) Solar Compatible jjjjj ...boilermanuals.org.uk/boilers/Eco Hometec/EC16,22,31... · eco hometec Unit 11E Carcroft Enterprise Park Carcroft Doncaster

10. Technical Information TTaabbllee 11 DDiimmeennssiioonnss && CCoonnnneeccttiioonnss Product Identification Number CE ~ 0085AR0057 Appliance Category 2ELL3B/P Dimensions (H x W x D) 950mm x 458mm x 355mm Heating Circuit Connections 22mm Gas Connection 15mm Condense Drain Connection ¾ BSP Air Supply/Flue Connections 125/80mm TTaabbllee 22 HHeeaattiinngg SSppeecciiffiiccaattiioonnss Models H, HS and S EC16 EC23 EC31 EC38 Maximum Rated Input kW 15 22 28 36 Nominal Output To Heating 80/600C kW 14.3 21.4 28.4 35.1 Minimum Output To Heating 80/600C kW 2.5 3.1 4.5 6.0 Nominal Output To Heating 50/300C kW 15.8 23.1 30.7 38.0 Minimum Output To Heating 50/300C kW 3.1 3.6 5.1 6.8 CO2 % content at max/min load CO2 % 9 9 9 9 Dew Point of Flue Gases 00C 52 52 52 52 Flue Gas Temp @ 80/600C (Amb 200C) 00C 75 75 75 75 * Maximum Flue Resistance Pa 100 100 100 100 pH value of condensate water PH 4-5.5 4-5.5 4-5.5 4-5.5 Pump Pressure @ 30kW and 20K Bar 0.2 0.15 0.1 0.075 Maximum Flow Temperature 00C 85 85 85 85 Min/Max filling pressure bar 0.5 - 3.0 0.5 - 3.0 0.5 - 3.0 0.5 –3.0 **Efficiency @ 75/600C % 104 104 104 104 **Efficiency @ 40/300C % 108.5 108.5 108.5 108.5 * At this resistance, the load will remain within the limits indicated on the data plate. ** European calculation methods are based on efficiency of 100% in units that do not condense the flue gases, and of 110% in condensing units. TTaabbllee 33 CCaappaacciittiieess && WWeeiigghhttss Model EC16 EC23 EC31 EC38 Heating Water Capacity litres 1.5 1.8 2.1 2.4 Heating Water Coil Capacity (S models) Litres 1 1.3 1.5 10 Weight (empty) Kg 35 37 39 50

EC 16~38 Installation Manual page 11

Page 12: Variable Controlled Output (VCO) Solar Compatible jjjjj ...boilermanuals.org.uk/boilers/Eco Hometec/EC16,22,31... · eco hometec Unit 11E Carcroft Enterprise Park Carcroft Doncaster

TTaabbllee 44 HHoott WWaatteerr SSppeecciiffiiccaattiioonnss Model EC16 EC23 EC31 EC38 Maximum Rated Input kW 22.0 28.0 36.0 46.0 Modulating Output kW 2.9-22.0 3.4-28 4.8-36.0 6.4-46.0 Hot Water Flow rates at ∆τ 30K (S type) L/min 10.5 13.4 17.2 22 Maximum Tap Water Pressure bar 10 10 10 10 TTaabbllee 55 CCoonnnneeccttiioonn VVaalluueess Min/Max Gas Pressure mbar 15/50 15/50 15/50 15/50 Minimum Input Rate Natural Gas m/h3 0.31 0.36 0.5 0.68 Maximum Input Rate Natural Gas m/h3 2.10 2.67 3.44 4.77 Electrical Supply VAC 230 230 230 230 Power Consumption Average W 60 60 60 60

Figure 1 Overall Dimensions mm.

Figure 2 Bottom View Dimensions mm.

Page 12 eco hometec (uk) ltd.

Page 13: Variable Controlled Output (VCO) Solar Compatible jjjjj ...boilermanuals.org.uk/boilers/Eco Hometec/EC16,22,31... · eco hometec Unit 11E Carcroft Enterprise Park Carcroft Doncaster

Figure 3 Top View Dimensions mm

11. Main Component Specification 11.1 Head Height of the Central Heating Circuit.

Figure 4 Pump Head Height

Volume of Water in Cu. Mts/ph. (m3/h.) Grundfoss 240 Volt ~ 50Hz Wattage 59 ~ 115 W

11.2 Air Fan Details.

Type. EBM GIG128~13~13

Figure 5 Air Fan Curve

11.3 Gas Control Valve.

Figure 6 Gas Valve

EC 16~38 Installation Manual page 13

Page 14: Variable Controlled Output (VCO) Solar Compatible jjjjj ...boilermanuals.org.uk/boilers/Eco Hometec/EC16,22,31... · eco hometec Unit 11E Carcroft Enterprise Park Carcroft Doncaster

12. Unpacking & Items Supplied The following items are supplied with the Boiler. Installation manual (to be left with the boiler). Replacement fuses (located top left of control panel). Vent key. Mounting bracket. Outside air temperature sensor 13. Accessories The following items are also available from eco hometec at extra cost. Colour coded 1/4 Turn Isolating Valves. Stainless Steel Flexible Pipe Connections. In line Filter/Strainers. Condensate sump pump for below ground installations. N.B. LPG installations must not be installed below ground level.

eco hometec servicing software and RS 2323 interface cable for connection to a PC. eco hometec RE2132 modulating room sensor. eco hometec EC30H Cable for connecting three way diverter valve (external to boiler). eco hometec cascade manager for controlling multiple boiler installations supplying heat to the same system. A maximum of five boilers can be connected. eco hometec PRO1 wall mounted pump control box to control one or more pumps in serial with the built in boiler pump. eco hometec MR 03 mixing valve control unit For more details please contact the eco hometec technical department.

eco hometec comprehensive range of PPS flue kits, fittings and accessories. 80/125 Concentric 500 mm Fanned Flue Kit 80/125 1000mm length PPS/White Galvanised Concentric Flue 80/125 500mm length PPS/White Galvanised Concentric Flue 80/125 PPS/White Galvanised 90 degree elbow 80/125 PPS/White Galvanised 45 degree elbow 80mm 1000mm PPS flue pipe 80mm PPS 45 degree PPS Elbow 80mm PPS 45 degree connector 80/125 Roof Terminal Pitched roof tile flashing Aluminium flat roof terminal/chimney top flashing 80mm Wall Fixing Clamp 125mm Wall Fixing Clamp 80mm PPS flexible flue liner (per metre) 80mm PPS flexible flue liner 360 degree spacers 80mm PPS flexible flue liner chimney terminal 80mm PPS flexible flue liner chimney terminal clamp 80mm PPS flexible flue liner boiler flue connector

Page 14 eco hometec (uk) ltd.

Page 15: Variable Controlled Output (VCO) Solar Compatible jjjjj ...boilermanuals.org.uk/boilers/Eco Hometec/EC16,22,31... · eco hometec Unit 11E Carcroft Enterprise Park Carcroft Doncaster

14. Operation A key component of the boiler is the ECONOX premixing, radiant, gas burner, which is capable of producing a Variable Controlled Output (20% to 100% ratio). A unique feature of the ECONOX burner I s its radiation cylinder, which has been specially designed to suit the geometry of the combustion chamber. It is composed of a perforated sheet of stainless steel with a metal fleece on its surface. On the surface of this burner, accurate quantities of premixed gas and air are burnt almost without a visible flame As a result of the extremely low combustion temperatures produced during this process, emissions of harmful atmospheric pollutants are dramatically reduced, (NOx 20mg\kWh CO 14mg\kWh). 14.1 Variable Controlled Output

The eco hometec on-board computerised V.C.O. system with integral fault diagnostic facility, ensures that optimum efficiency is maintained when operating in both heating and DHW modes. According to the required flow temperature, the premixing radiant burner modulates. To save electricity, a 24-Volt, high efficiency fan is used with a variable speed and power capacity; if the heat demand decreases, the fan will turn at a lower speed, which results in a lower power consumption. The fan is programmed to supply given amounts of air for specific burner outputs. This air pressure then controls the gas valve which in turn, matches the gas pressure to the required gas to air ratio (1:1). The combustion gases are then passed down through the SPIRANOX stainless steel heat exchanger to atmosphere. During their passage these hot gases are used to preheat both the return water to the boiler and the incoming combustion air, thus

ensuring that all of the available energy is used as efficiently as possible. 14.2 Variable pump

A variable speed integral circulating pump is supplied, which operates at different speeds and results in a lower power consumption (between 30 and 119 Watts). This feature is to help maintain a temperature difference of 20OC between the flow and return temperatures on systems using radiators. 14.3 Frost Protection

If the flow temperature falls below 80C, in order to provide frost protection, the pump will run even though there may be no demand for heat. If the temperature continues to fall, at 50C, the burner will also ignite. At 100C the appliance will return to standby mode. 14.4 Year Long Protection

During summer months, the pump and mixer valve (if fitted) are exercised daily. This prevents seizure of internal components thus reducing maintenance costs.

Remember when handing over the appliance to advise the end user on the precautions necessary to prevent frost damage to the system during frosty conditions. Stress the importance of leaving the system turned on e.g continuous low temperature setting in extremely cold weather. 15. Siting the Appliance

In siting the boiler, the following limitations MUST be observed The boiler is not suitable for external use. The position selected for installation MUST allow adequate space for servicing in front and below the boiler and for the circulation of ventilation air around the boiler. Figure 8 shows the minimum clearances required for safety and subsequent service. The position must allow for the correct routing of a flue system.

EC 16~38 Installation Manual page 15

Page 16: Variable Controlled Output (VCO) Solar Compatible jjjjj ...boilermanuals.org.uk/boilers/Eco Hometec/EC16,22,31... · eco hometec Unit 11E Carcroft Enterprise Park Carcroft Doncaster

The room must be dry and protected from frost. All eco hometec appliances are condensing and pluming at the flue is a normal occurrence. Flue terminal positions where this, or the noise of flue gases discharging from the flue could be a nuisance must be avoided. Normally no part of the appliance, other than the water pipe-work (850C) and flue pipe (750C), will exceed 650C. However, any combustible material near to the boiler or its flue system and water pipe-work must be protected to ensure it does not exceed 650C.

In certain locations the flue outlet may be susceptible to high winds or air turbulence. Sudden gusts may create a negative flue pressure. Flue terminal outlets in such exposed conditions should be avoided. When operating at low fan speeds flame lift may occur. This can be overcome by raising the minimum fan speed.

It is advisable when installing the boiler to use an eco hometec P.P.S. plastic concentric flue system. This not only ensures that there is sufficient combustion air, but also reduces room ventilation requirements thus increasing the number of possible suitable locations. The EC VCO MODELS may be installed on the inner face of an external wall and some internal walls providing they are flat, vertical, of a non-combustible material and are capable of supporting the weight of the boiler and any other ancillary equipment. Where installation will be in an unusual location, special procedures may be necessary. Detailed guidance on this subject can be found in BS. 6798. 15.1 Timber Framed Dwellings

When installing the EC VCO MODELS into a timber framed dwelling, it must be fitted in accordance with the British Gas publication ‘Guide for Gas Installations in Timber Framed Housing’ ref. DM2. For further advice contact the eco hometec Technical Helpline.

16. Hydraulic Connections 16.1 First Fixing Pipe-work

All the pipe-work and wiring connections enter at the bottom of the unit. To ensure a tidy installation it is important to consider at the first fixing stage the order you arrange the pipe-work and if applicable any cable trunking. Figure 7 shows the order in which to fix the pipe-work. Figure 7 Pipe-work Layouts

16.2 Type ‘H’ Connections

1) Cable Gland 2) Syphon Flush (No permanent

connection required) 3) Heating Flow ~ 22mm 4) Additional Cable Entry Point 5) Not applicable to H model 6) Gas Inlet ~ 15mm. 7) Not applicable to H model 8) Heating Return ~ 22mm. 9) Condensate Discharge ~ ¾ M.I.

16.3 Type ’HS’ Connections.

1) Cable Gland 2) Syphon Flush (No permanent

connection required) 3) Heating Flow ~ 22mm 4) Additional Cable Entry Point 5) Flow Domestic Hot Water 22mm 6) Gas Inlet ~ 15mm 7) Return Domestic Hot Water 22mm 8) Heating Return ~ 22mm 9) Condensate Discharge ~ ¾ M.I.

Page 16 eco hometec (uk) ltd.

Page 17: Variable Controlled Output (VCO) Solar Compatible jjjjj ...boilermanuals.org.uk/boilers/Eco Hometec/EC16,22,31... · eco hometec Unit 11E Carcroft Enterprise Park Carcroft Doncaster

16.4 ‘S’ Connections.

1) Cable Gland 2) Syphon Flush (No permanent

connection required) 16.7 Fixing the boiler.

3) Heating Flow ~ 22mm. 4) Additional Cable Entry Point 5) Flow Domestic Hot Water 22mm 6) Gas Inlet ~ 15mm 7) Cold Mains Water ~ 22mm 8) Heating Return ~ 22mm 9) Condensate Discharge ~ ¾ M.I.

16.5 Clearances

For ease of installation, necessary inspection and commissioning, the following clearances are recommended. TTaabbllee 66 MMiinniimmuumm CClleeaarraanncceess

Sides 50mm Above 250mm Below 150mm Front 455mm

Figure 8 Minimum Clearances

16.6 Checks Before Siting

Before commencing to install this appliance ensure the design specification complies with all of the requirements contained in these installation and servicing instructions and any statutory documents which may apply.

The manufacturers instructions must not be allowed to override statutory

requirements. More than one person may be required to install the appliance.

When unpacking the unit for the first time, take adequate precautions to protect the surrounding floor coverings. The boilers are factory tested and contain residues of water that could cause dampness and possible staining if contact with carpets and floor coverings is not prevented. Unpack the appliance and ensure that the items listed on page 14 have been supplied. 16.8 Removing The Casing

To remove the casing lay the unit down on the floor with the casing facing upper most. Loosen the centre screw and undo the two toggle casing clips located on the bottom of the unit. Pull the casing upwards, lifting up and off the internal locating lugs. Place the casing to one side taking care not to scratch the casing or control panel cover. (see figure 9.)

Figure 9 Removing the Casing

Take any necessary precautions to protect the surrounding working area and decorations from dust and damage. Make one final check on the location pay particular attention to the flue outlet (consider pluming) and the condensate discharge pipe route.

EC 16~38 Installation Manual page 17

Page 18: Variable Controlled Output (VCO) Solar Compatible jjjjj ...boilermanuals.org.uk/boilers/Eco Hometec/EC16,22,31... · eco hometec Unit 11E Carcroft Enterprise Park Carcroft Doncaster

Install the combi model as close as possible to the hot water taps to avoid the hot water pipes from becoming too long. This prevents long delays and unnecessary waste of water. When you are satisfied the location meets all the required criteria mark out the wall for required fixing points. Use the fixing bracket as a template.

Figure 10 Fixing Dimensions

Check for horizontal and vertical alignment and drill 4 holes as marked using a No.14 masonry drill. Clear the surrounding area of any dust and debris and secure the mounting frame to the wall using suitable screws and plugs. Locate the boiler on the mounting frame.

The appliance should be 10mm off the wall measured at the base of the panel. Failure to observe this will result in condensate becoming trapped inside the heat exchanger. Component failures as a result of incorrect installation will not be covered by the boilers normal warranty. Please remember when using power tools to take all necessary safety precautions and always wear safety goggles. 17. Flues and Ventilation The internal boiler flue system is manufactured in P.P.S plastic and the flue outlet may be connected to an external P.P.S plastic or stainless steel flue system. 17.1 Maximum Flue Lengths

The flue materials, flue insulation, the amount of vertical and horizontal pipe and the amount of bends incorporated determine the maximum permissible flue length. The excess fan pressure available for overcoming the frictional resistance of the flue system is 100 p.a.

Page 18 eco hometec (uk) ltd.

Page 19: Variable Controlled Output (VCO) Solar Compatible jjjjj ...boilermanuals.org.uk/boilers/Eco Hometec/EC16,22,31... · eco hometec Unit 11E Carcroft Enterprise Park Carcroft Doncaster

Figure 11 Flue Design

Boiler output in relation to available flue Palower outputs = more Pa and longer flue lengths

0

50

100

150

200

250

300

350

400

450

500

25 26 27 28 29 30 31 32 33

Boiler output ~kW

Ava

ilabl

e flu

e ~

Pa

For the purposes of flue design when using the eco hometec PPS 125mm/80mm concentric flue system then refer to the table below for component resistances. TTaabbllee 77 FFlluuee RReessiissttaannccee COMPONENT RESISTANCE 80/125 Concentric 500 mm Fanned Flue Kit 80/125 1000mm length PPS/White Galvanised Concentric Flue 80/125 500mm length PPS/White Galvanised Concentric Flue 80/125 PPS/White Galvanised 900 elbow 80/125 PPS/White Galvanised 450 elbow 80mm 1000mm PPS flue pipe 80mm PPS 900 elbow 80mm PPS 450 elbow 80/125 Roof Terminal Open terminal with stainless steel mesh

P.a 5.0 4.5 2.25 4.0 2.0 2.5 1.0 .5 7.5 2.5

For vertical external and internal flues there is a further gain from thermal lift. This can be calculated from the graph below.

EC 16~38 Installation Manual page 19

Page 20: Variable Controlled Output (VCO) Solar Compatible jjjjj ...boilermanuals.org.uk/boilers/Eco Hometec/EC16,22,31... · eco hometec Unit 11E Carcroft Enterprise Park Carcroft Doncaster

Figure 12 Thermal Lift

Thermal lift when flue gas temp 80C and outside temp 10C

0

20

40

60

80

100

120

140

160

180

0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50Flue lengths ~ metres

Dra

ught

~ P

a

Uninsulated Flue

Insulated Flue

Thermal lift is generated naturally in the vertical part of a flue system, reducing the overall resistance of the system. The available lift may be calculated from the Thermal lift graph and deducted from the total calculated flue resistance. 17.2 Available Flue Components

80/125 Concentric 500 mm Fanned Flue Kit 80/125 1000mm length PPS/White Galvanised Concentric Flue 80/125 500mm length PPS/White Galvanised Concentric Flue 80/125 PPS/White Galvanised 90 degree elbow 80/125 PPS/White Galvanised 45 degree elbow 80mm 1000mm PPS flue pipe 80mm PPS 45 degree PPS Elbow 80mm PPS 45 degree connector 80/125 Roof Terminal Pitched roof tile flashing Aluminium flat roof terminal/chimney top flashing 80mm Wall Fixing Clamp 125mm Wall Fixing Clamp 80mm PPS flexible flue liner (per metre) 80mm PPS flexible flue liner 360-degree spacers 80mm PPS flexible flue liner chimney terminal 80mm PPS flexible flue liner chimney terminal clamp 80mm PPS flexible flue liner boiler flue connector

Page 20 eco hometec (uk) ltd.

Page 21: Variable Controlled Output (VCO) Solar Compatible jjjjj ...boilermanuals.org.uk/boilers/Eco Hometec/EC16,22,31... · eco hometec Unit 11E Carcroft Enterprise Park Carcroft Doncaster

For installations requiring greater flue lengths - please contact the eco hometec technical department for advise. The flue should terminate with a suitable terminal. 17.3 Pluming

The siting of the terminal is not critical with regard to the performance of the appliance. However In certain locations the flue outlet may be susceptible to high winds or air turbulence. Sudden gusts may create a negative flue pressure. Flue terminal outlets in such exposed conditions should be avoided. When operating at low fan speeds flame lift may occur. This can be overcome by raising the minimum fan speed. In certain conditions pluming from the flue, although harmless, may cause a nuisance.

Please site the flue outlet to minimise any inconvenience the discharge of combustion products or possible pluming may cause. Where a terminal is so sited to be less than 2m above the level of any ground, balcony, flat roof, or place to which people have access, or there is a likelihood of accidental contact by persons or damage to the terminal, a suitable guard MUST be fitted. Terminal guards are available from eco hometec. 17.4 Condensate in the Flue

Condensate formed must be cleared from the flue system and adequate care is required to ensure all flue pipes are self draining. All internal and external potential collecting points must be drained. In addition to avoid freezing external flue ductwork must be insulated. To ensure the safe and satisfactory operation of the boiler the chimney system must be capable of the complete evacuation of combustion products at all times. 17.5 Flueing Options

The boiler may be installed either as a room sealed, fanned flued appliance using the

eco hometec P.P.S plastic 125mm/80mm concentric flue system or alternatively, conventionally flued, using a single skin 80mm P.P.S. plastic pipe. 17.6 Installing a Concentric Flue

Connect the concentric elbow into the flue/vent connection. Mark the wall around the flue, remove the concentric elbow cover the appliance and cut or drill a 130mm diameter hole through the wall. Measure and cut the concentric flue pipe to pass through the previously made hole and into the concentric 90o bend.

Figure 13 Flue Preparation

EC 16~38 Installation Manual page 21

Page 22: Variable Controlled Output (VCO) Solar Compatible jjjjj ...boilermanuals.org.uk/boilers/Eco Hometec/EC16,22,31... · eco hometec Unit 11E Carcroft Enterprise Park Carcroft Doncaster

Figure 14 Dimensions for cutting flue hole

Apply a chamfered edge to the cut ends, apply silicone lubricant and insert through the wall and into the flue/air socket. The overall projection of the finished pipe should leave the air holes 20mm clear of the surrounding wall as per figure 15. NOTE: When fitted, it is important to position the flue outlet with a slight fall so that the 80mm flue pipe is sloped back towards the boiler. Failure to observe this requirement will result in condensate running out of the flue pipe and over the external brickwork causing possible staining and or freezing. Installed correctly the flue pipe will self drain back through the boilers internal condensate route. Make good to internal and external walls and fix an external stainless steel terminal guard if required.

Figure 15 Wall Terminal

The final location of the Flue Outlet terminal should comply with figure 23 and table 8. In certain circumstances the location of the boiler may leave the flue outlet in a position that does not comply with figure 23, or where pluming is a nuisance. The eco hometec flue system has been designed to overcome this and the 80mm P.P.S. flue pipe may be simply re-routed to terminate in a more suitable location. To do this simply remove the 80mm stainless steel flue grill and insert either a 900 or 450

bend Note: two 450 may be used to form a swan neck returning the flue pipe back to the wall for clipping. Route the pipe to the desired location and terminate with a suitable bend to direct the flue gases away from the wall or any obstruction. When you are satisfied that the location complies with the requirements of figure 23 replace the stainless steel 80mm flue grill.. Alternatively a 900 terminal fitting may be purchased from eco hometec and the flue routed vertically.

Page 22 eco hometec (uk) ltd.

Page 23: Variable Controlled Output (VCO) Solar Compatible jjjjj ...boilermanuals.org.uk/boilers/Eco Hometec/EC16,22,31... · eco hometec Unit 11E Carcroft Enterprise Park Carcroft Doncaster

Figure 16 Vertical Wall Terminal

17.7 Vertical flue Installations

For vertical flue applications a range of fittings for both pitched and flat roofs are available. Please contact eco hometec for further advice.

Figure 17 Vertical Flue Application

17.8 Modular Installations

For multiple boiler (modular) installations eco hometec supply a range of larger diameter flues. Sizes are available in 150mm, 200mm and 250mm. For assistance in flue design and specification please call the eco hometec technical department.

Figure 18 Modular Installation

EC 16~38 Installation Manual page 23

Page 24: Variable Controlled Output (VCO) Solar Compatible jjjjj ...boilermanuals.org.uk/boilers/Eco Hometec/EC16,22,31... · eco hometec Unit 11E Carcroft Enterprise Park Carcroft Doncaster

Figure 19 Vertical Roof Terminals

Concentric vertical flue fittings are available from eco hometec. Concentric flue components have push together spigot and socket joints. The inner PPS flue gas tube has silicone seal rings located in the socket component. The outer air tube has EPDM rubber seal rings located in the socket component. To aid assembly and assurance that the joints have been fully pushed home, the seal rings and make ends of tubes and fittings should be lightly lubricated with silicone grease. Additional 80/125mm concentric flues tubes and fittings are available from eco hometec details below:

Page 24 eco hometec (uk) ltd.

Page 25: Variable Controlled Output (VCO) Solar Compatible jjjjj ...boilermanuals.org.uk/boilers/Eco Hometec/EC16,22,31... · eco hometec Unit 11E Carcroft Enterprise Park Carcroft Doncaster

Figure 20 Concentric flue fittings

80/125 1000mm length PPS/White Galvanised Concentric Flue 80/125 500mm length PPS/White Galvanised Concentric Flue 80/125 PPS/White Galvanised 90 degree elbow 80/125 PPS/White Galvanised 45 degree elbow 125mm Wall Fixing Clamp

Figure 21 Concentric 80mm adaptor

The concentric 80mm double adaptor is used to separate the air flue gas tubes. Both air and flue gas may be pied separately and if required in different directions. Additional 80 PPS flues tubes and fittings are available from eco hometec details below:

Figure 22 80mm Flue Tubes

80mm 1000mm PPS flue pipe 80mm PPS 45 degree PPS Elbow 80mm PPS 45 degree connector 80mm Wall Fixing Clamp 80mm – 100mm increaser A range of Flexible Flue liners are also available details below. 80mm PPS flexible flue liner (metre) 80mm PPS flexible flue liner 360-degree spacers 80mm PPS flexible flue liner chimney terminal 80mm PPS flexible flue liner chimney terminal clamp 80mm PPS flexible flue liner boiler flue connector

EC 16~38 Installation Manual page 25

Page 26: Variable Controlled Output (VCO) Solar Compatible jjjjj ...boilermanuals.org.uk/boilers/Eco Hometec/EC16,22,31... · eco hometec Unit 11E Carcroft Enterprise Park Carcroft Doncaster

17.9 Fan Flued Terminal Positions

Figure 23 Fan Flued Terminal Positions

TTaabbllee 88 FFlluuee TTeerrmmiinnaall PPoossiittiioonnss.. Terminal Positions Min.Distance A: Directly below an opening window or other opening, e.g. air brick 300mm Directly above an opening window or other opening, e.g. air brick 300mm B: Below gutters, soil pipes or drain pipes. 75mm C: Below eaves 200mm D: Below balconies or car port roof 200mm E: From vertical drain pipes and soil pipes 150mm F: From internal and external corners 300mm G: Above ground roof or balcony 300mm H: From a surface facing a terminal 600mm J: From an opening in a car port (e.g. door, window) into a dwelling 1200mm K: Vertically from a terminal on the same wall 1500mm L: Horizontally from a terminal on the same wall 300mm 18. Gas Supply The boiler is set for use with natural gas. 18.1 Gas Supply

Pipe-work from the meter to the boiler MUST be of an adequate size. DO NOT use pipes of smaller size than the boiler inlet gas connection.

The gas supply to the boiler must be capable of maintaining a minimum pressure of 20 mbar measured at the inlet to the boiler, with all other gas appliances working. The installer should install a pressure test point adjacent to the gas inlet connection.

Page 26 eco hometec (uk) ltd.

Page 27: Variable Controlled Output (VCO) Solar Compatible jjjjj ...boilermanuals.org.uk/boilers/Eco Hometec/EC16,22,31... · eco hometec Unit 11E Carcroft Enterprise Park Carcroft Doncaster

18.2 LPG Gas Supply

For LPG the gas supply to the boiler must be capable of maintaining a minimum pressure of 37 mbar measured at the inlet to the boiler, with all other gas appliances working.

The complete installation MUST be tested for soundness and purged in accordance with C.P. 331.3

The gas valve fitted to the boiler is not designed to withstand pressures in excess of 60 mbar. When carrying out the pressure test on the service pipe-work it is essential that the gas cock fitted to the boiler is in the closed position, failure to do so will result in serious damage to the boiler. 18.3 Setting The Gas Type

When the EC VCO MODELS leaves the factory it set up for use with Natural Gas. It can however be easily adjusted for use with LPG 18.4 Conversion to LPG

If the appliance is being used with LPG then a conversion kit is available form eco hometec. The contents of the LPG conversion kit include the following items: 1 x Propane injector 5.7mm 1 x Injector 3.5mm 1 x 10mm plastic air box plug (for EC 16 & 23) 1 x 15mm plastic air box plug (for EC 31) 1 x 13mm plastic air box plug (for EC 38) To convert the appliance to LPG complete the following procedure. Isolate the boiler from the gas and electricity supplies. Disconnect the unions either side of the gas valve.

Screw the 3.5 injector into the gas inlet side of the valve and the 5.7mm injector into the gas outlet side of the valve. Close the hole in the front of the air box (attached to the air fan assembly) using a plastic plug included in the conversion kit. EC38 only close the hole in the rear of the air box (attached to the air fan assembly) using a plastic plug included in the conversion kit. Re-connect the gas valve making sure the sealing washers are located properly. Turn on gas supply and check for gas soundness. Write on the identification plate that the appliance has been converted for LPG. All gas service pipe-work from the meter to the boiler should be either mild steel pipe or copper.

EC 16~38 Installation Manual page 27

Page 28: Variable Controlled Output (VCO) Solar Compatible jjjjj ...boilermanuals.org.uk/boilers/Eco Hometec/EC16,22,31... · eco hometec Unit 11E Carcroft Enterprise Park Carcroft Doncaster

19. Air Supply 19.1 Concentric Flue

If installed with a concentric flue and as a room sealed appliance the boiler does not require that room or internal space to have a permanent air supply. 19.2 Conventionally Flue

Safe, efficient and trouble-free operation of conventionally flued gas boilers is vitally dependant on the provision of an adequate supply of fresh air to the room in which the appliance is installed. Ventilation by grilles

communicating directly with the outside air or a ventilated adjacent room is required. Where the combustion air is being taken from an adjoining room the room itself must be ventilated to satisfy the combustion air requirement of the appliance. Where the appliance is to be installed as a conventionally flued appliance sufficient combustion air should also be allowed. To calculate the amount of free combustion air required for the appliance table 9 should be used. Permanent openings are based on the total maximum rated input.

Position ventilation grilles to avoid the risk of accidental obstruction by blocking or flooding. BS 5540.2 TTaabbllee 99 VVeennttiillaattiioonn Vent Position Into room or internal

space Direct to outside air

High level 9 cm2 per kW of input 4.5 cm2 per kW of input Low level 9 cm2 per kW of input 4.5 cm2 per kW of input In a room or internal space None required None required Conventionally flued appliance

Vent Position Into room or internal space

Direct to outside air

High level 9 cm2 per kW of input 4.5 cm2 per kW of input Low level 18 cm2 per kW of input 9.0 cm2 per kW of input Any air vent, which is to supply air to an open flued appliance, must not communicate with any room/space containing a bath or shower or private garage. If further guidance on ventilation is required then consult BS. 5440.2. Detailed recommendations for air supply requirements are given in BS.5440.2. and can also be found in the CORGI Gas

Installer Manual. The following notes are intended for general guidance only. Where open flued appliances total input ratings exceed 7 kW the room or internal space containing them must have an air vent of minimum effective area 4.5 cm2

for every 1 kW in excess of 7 kW. 19.3 Compartment Ventilation

Due to the low standing losses compartment ventilation is not required.

Page 28 eco hometec (uk) ltd.

Page 29: Variable Controlled Output (VCO) Solar Compatible jjjjj ...boilermanuals.org.uk/boilers/Eco Hometec/EC16,22,31... · eco hometec Unit 11E Carcroft Enterprise Park Carcroft Doncaster

20. Hydraulic Requirements

The boilers are intended to be used in conjunction with FULLY PUMPED, SEALED systems subject to the requirements below. They are NOT SUITABLE for use on gravity circulation systems. The boiler must NOT be used for direct hot water supply. Underfloor Systems

Despite the low boiler flow temperatures feature, in the event of control and/or mechanical failure or incorrect adjustment, to prevent damage to the installation or associated pipe work ALL low temperature under floor installations require an obligatory mixing valve installing as part of the system controls or a high limit thermostat set at 60oC to interrupt the demand for heat signal from the underfloor heating controls. EC38S and all Combi Types In hard water areas suitable protection should be provided to prevent the build up of deposits in the primary hot water heat exchanger. The appliance guarantee does not extend to failure as a result of lime scale or other contamination. 38kW Models Only. These appliance requires an expansion vessel and a 3 bar pressure relied valve to be fitted to the system

MAKE SURE ASUITABLE SIZED EXPANSION TANK AND A 3BAR PRESSURE RELIEF VALVE ARE FITTED TO THE SYSTEM AND THE DISCHARGE PIPE TERMINATES TO A SAFE LOCATION The central heating system should be in accordance with the recommendations given in BS. 6798 and BS. 5449.

Hot water cylinders must be double feed indirect and to aid efficiency and fast recovery times (all appliances are hot water priority) should be of the high recovery type.

Recommended minimum coil capacity 25kW. The boiler must be capable of being adequately vented of air. Drain taps MUST be located in accessible positions, which permit the draining of the whole system - including the boiler and hot water storage vessel. Drain taps should be at least 1/2 inch BSP nominal size and be in accordance with BS. 2879.

In order to facilitate servicing of the unit, full flow isolating valves must be fitted to all water and gas connections, (these valves can be supplied by eco hometec as an optional extra if required). 20.1 Expansion Vessel

Depending on specification chosen the appliance may be fitted with a 10 litre expansion vessel.

An expansion vessel must be fitted to all systems and for those boilers supplied with an expansion vessel if the system water content exceeds the limit an additional vessel will be required. For systems having a larger water capacity, multiply the total water content (boiler and system) by the factor to obtain vessel size in litres. TTaabbllee 1100 EExxppaannssiioonn VVeesssseell RReeqq.. *Vessel Charge & Initial System Pressure *VC&ISP 0.5 bar 1.0 bar 1.5 bar Factor 0.08 bar 0.11 bar 0.16 bar EXAMPLE 1. Central heating system filled to 1 bar. Total system water content 60 litres Multiply 60 (water content litres) x 0.11 (factor from chart) = 6.6 litres. Vessel required 6.6 litres. Vessel supplied 10 litres. Vessel adequate. EXAMPLE 2. Central heating system filled to 1 bar. Total system water content 150 litres

EC 16~38 Installation Manual page 29

Page 30: Variable Controlled Output (VCO) Solar Compatible jjjjj ...boilermanuals.org.uk/boilers/Eco Hometec/EC16,22,31... · eco hometec Unit 11E Carcroft Enterprise Park Carcroft Doncaster

Multiply 150 (water content litres) x 0.11 (factor from chart) = 16.5 litres. Vessel required 16.5 litres. Vessel supplied 10 litres. Vessel inadequate. Additional vessel 6.5 litres required. When system content unknown or difficult to determine the following table can assist with calculating water content. TTaabbllee 1111 SSyysstteemm CCoonntteennttss Approx. Litres per

kW New Radiators 9 Old Radiators 13 U/Floor Heating

22

Expansion vessels should be connected to the system at a point close to the pump inlet in order to maintain positive pressure throughout the system. The central heating system should be in accordance with the recommendations given in BS. 6798 and BS. 5449. 20.2 Hydraulic Resistance

The integral boiler pump is designed to provide an adequate flow rate through the boiler at all times. Therefore, if an additional duty pump is to be fitted to the system, the boiler resistance can be ignored. A PRO1 pump control box is available from eco hometec. When connected directly to the boiler control panel it will control external duty pumps via the boiler. This feature maintains the built in summer and winter pump protection. 20.3 Condensate Drain

The condense discharge pipe should be continued in ¾ inch plastic waste pipe into the household drainage system or out through the wall to an existing gully or soak

away. To minimise the risk of freezing all condensate waste pipe-work fitted externally should be 32mm. (The existing drainage system should be corrosion resistant).

In order to avoid damage to the boiler caused by a blocked drainage system, the condense disposal pipe should include a tundish. In these cases the pipe-work connected to the internal household drainage system should be fitted with a deep seal running trap.

Horizontal runs of condense discharge pipe must fall at a rate of 40mm per metre and any external sections of pipe must be protected against the risk of freezing. Due care should be taken when installing the condensate disposal system to minimise the risk of blockage, as this would cause the condensate to back up inside the boiler. eco hometec will not accept any liability for damage caused to the boiler should this situation occur. If the connection to an existing drain is not possible, the condensate may be discharged in to a purpose-built soak away. For further information regarding the construction of a soak away, please contact the eco hometec Technical Support Department. When the boiler is installed below ground level, i.e. a basement or cellar, (NB the appliance must not be installed below ground when using LPG) provision should be made for the disposal of the condensate via a sump pump arrangement. 20.4 System By-Pass

The boiler incorporates a bypass making it unnecessary to fit a system bypass. Please contact eco hometec Technical Department for more information if required.

Page 30 eco hometec (uk) ltd.

Page 31: Variable Controlled Output (VCO) Solar Compatible jjjjj ...boilermanuals.org.uk/boilers/Eco Hometec/EC16,22,31... · eco hometec Unit 11E Carcroft Enterprise Park Carcroft Doncaster

Figure 24 H Type Hydraulic system design

Typical EC H installation serving domestic hot water and heating using integral expansion vessel and modulating circulating pump. Hot water production has priority controlled by spring return to heating divertor valve wired to boiler. Flow temperature to hot water is constant temperature to heating may be fixed or variable (weather compensated).

OS EC H Model fitted to Hot Water Cylinder & Heating Circuit

OS = Outside air temperature sensor, used where integral boiler control weather compensated heating flow temperatures are requiredRT= Room temperature or remote time/temperature control requirede.g low voltage RE2132 modulating room unit from eco hometec or any240 volt time and/or temperature controller

= Divertor valve wired to boiler. This valve must be of the spring return to heating type when hot water cylinder stat satisfied

RT

Condensate waste via tundishExpansionVessel

Gas SupplyHOT WATER Strainer

U/FLOOR and/or RADIATORS

DOCAdditional Heating Zone/s

CYLINDERHEATING CIRCUIT/S

Cyl.Stat

CWM

Filling Loop

Figure 25 HS Type Hydraulic system design

Typical EC HS installation serving domestic hot water and heating using integral expansion vessel and modulating circulating pump. Hot water production has priority controlled by on boiler spring return divertor valve and cylinder thermostat wired to boiler. Flow temperature to hot water is constant; temperature to heating may be fixed or variable (weather compensated).

OS EC HS Model fitted to Hot W ater Cylinder & Heating Circuit

OS = Outside air tem perature sensor, used where direct-on-boiler weather com pensated heating flow tem peratures are requiredRT= Room tem perature or rem ote tim e/tem perature control requirede.g low voltage RE2132 m odulating room unit from eco hom etec or any240 volt tim e/tem perature controller

RT

Condensate waste via tundishExpansionVessel

Gas SupplyHOT W ATER Strainer

U/FLOOR and/or RADIATORS

DOCDOC Additional Heating Zone/s

CYLINDERHEATING CIRCUIT/S

Cyl.Stat

CW M

Filling Loop

EC 16~38 Installation Manual page 31

Page 32: Variable Controlled Output (VCO) Solar Compatible jjjjj ...boilermanuals.org.uk/boilers/Eco Hometec/EC16,22,31... · eco hometec Unit 11E Carcroft Enterprise Park Carcroft Doncaster

Figure 26 S Type Combi Hydraulic system design

(IMPORTANT SEE NOTE REF: 38/46kW model) Typical EC S (Combi) installation serving domestic hot water and heating using integral expansion vessel and modulating circulating pump. How water production has priority. Maximum flow temperature of hot water is constant temperature to heating may be fixed or variable (weather compensated).

OS EC S Model (Combi) fitted to heating Circuit

OS = Outside air temperature sensor, used where direct-on-boweather compensated heating flow temperatures are requiredRT= Room temperature or remote time/temperature control reqe.g low voltage RE2132 modulating room unit from eco homete240 volt time/temperature controller

RT

Condensate waste via tundishExpansionVessel

Gas SupplyStrainer

U/FLOOR and/or RADIATORS

DOCAdditional Heating Zone/s

HEATING CIRCUIT/S

IMPORTANT38kW models do not have

expansion tank or 3bar pressure reliefvalve. These items should be fiited as

part of the installation

CWM

Filling Loop

Descaler

HW to Taps

Figure 27 Electrical Connections

L1 N L1 N L2 L1 N 1 2 3 4 R1 R2 R3 R2 R3

2 5 1heating pump

Modulating Room Sensor

on zone valve IMPORTANT DO NOT CONNECT 240 VOLTS TO THIS TERMINAL RAIL

Link left & middleneutral

or

Outside SensorDivertor Valve

PRO1 or MRO3Fused 3amp240V SwitchedSpur with Neon

Low Voltage terminal rail with supply from boiler toCylinder Thermostat or sensor, Outside sensor

and RE2132 Modulating room sensor

Cyl Stat

Do NotUse

RE2132

voltage rail lower left hand side

Pump orSpring Return

240V to external

HW Primary

Modules or

Weiland PlugNumber One

240Volt wiring terminals mountedinside the boiler behind the low

Room Stat or

Room Stat orProgrammable

sensoruse end switch

T T

Page 32 eco hometec (uk) ltd.

Page 33: Variable Controlled Output (VCO) Solar Compatible jjjjj ...boilermanuals.org.uk/boilers/Eco Hometec/EC16,22,31... · eco hometec Unit 11E Carcroft Enterprise Park Carcroft Doncaster

21. Electrical Connections The boiler has a “Wieland” plug connector for connection to the mains as part of the wiring centre located at the bottom left hand side of the boiler.

Any external wiring to the boiler must be carried out in accordance with the IEE Wiring Regulations and any local regulations. The EC VCO MODELS is designed for 230 ~ 240v 50Hz single phase operation. The method of connection to the mains supply should allow for complete electrical isolation of the boiler, preferably by labelled double pole switched spur. The boiler must be protected by a 3 amp fuse. The point of connection to the mains should be readily accessible and adjacent to the boiler. If the boiler is to be sited in a bathroom the connection should be outside the room. It is essential that the electrical supply in the property should be properly earthed in accordance with current IEE Wiring Regulations.

Figure 28 Connecting to the Mains

` Using 3 core 1.5mm2 cable connect the boiler to the mains electrical supply by passing the cable through the cable duct and connecting to the Wieland connector as shown in figure 28.

22. Heating Control Options There are various ways of controlling the heating system from the boiler. Using a regular room thermostat. If a room thermostat is installed there must not be any thermostatic radiator valves on the radiator in that room. Using a RE2132 room unit With this special type of room thermostat, available only from eco hometec, the boiler can be regulated in a modulating fashion. Please contact the eco hometec technical department for more information. If a RE2132 room unit is installed there must not be any thermostatic radiator valves on the radiator in that room. Using the built-in weather compensating control This only requires an outside temperature sensor. (Mounted on North facing wall) The on board boiler weather compensating controller is adjusted so the relationship between the outside temperature and the boilers flow temperature is sufficient to maintain the building temperature. As the outside air temperature rises and falls a modulating control is achieved. Set up this way the temperature for the house is not controlled from one room, but on the basis of the outside temperature. Using a regular room thermostat, it is also possible to change the relationship between the outside temperature and the supply temperature. Outside temperature is the preferred control if control from one room is not required or not possible. If outside temperature control is used, the radiators must be fitted with thermostatic valves. 22.1 240 Volt Connections

The 240 volt terminal strip can be used to connect the following. External pump(s) with a maximum of 500 Watt. This connection will supply external pump(s) when the boilers integral pump is running. A 240 Volt room thermostat.

EC 16~38 Installation Manual page 33

Page 34: Variable Controlled Output (VCO) Solar Compatible jjjjj ...boilermanuals.org.uk/boilers/Eco Hometec/EC16,22,31... · eco hometec Unit 11E Carcroft Enterprise Park Carcroft Doncaster

Switch over three way valve (spring return type) or loading pump for the hot water cylinder. Three way modulating mixing valve for a secondary circuit. The mixing valve and pump for this circuit has to be wired back to the control unit MR03 (available form eco hometec) an additional pump greater than 500watts may also be connected to the control unit PR01 both the MR03 or the PR01 should be connected to L1 & N 22.2 Low Voltage Connections

The low voltage terminal strip can be used to connect the following. Hot water cylinder sensor. External temperature sensor. RE2132 Modulating room sensor. All of the above are available form eco hometec

Do not connect 240 volts to the low voltage terminal strip. 22.3 Built-in clock

The appliance has a unique built-in 3 channel programmable time clock. This enables not only the setting of the heating times for various temperatures, but also the heating times for hot water. During programmed off periods Combi models (‘S’ types) will maintain a minimum storage temperature of 40oC. For H and HS type appliances connected to hot water cylinder for this function to operate temperature control has to be provided with a sensor (available from eco hometec). When hot water temperature control is provided by a cylinder thermostat this function is not recognised. 23. Boiler Control panel

Figure 29 Boiler Control panel

Page 34 eco hometec (uk) ltd.

Page 35: Variable Controlled Output (VCO) Solar Compatible jjjjj ...boilermanuals.org.uk/boilers/Eco Hometec/EC16,22,31... · eco hometec Unit 11E Carcroft Enterprise Park Carcroft Doncaster

24. Boiler Control Panel The boiler control panel incorporates the following features. 24.1 System water pressure gauge

Informs user of current system water pressure. 24.2 On / off switch

Boiler isolating switch.

Always switch to the OFF position when working on the unit. 24.3 Lcd control display

The display has two lines: the upper line indicates the current operating status e.g HW DEMAND and either “S” (summer) or “W” (winter / “D” (day) or “n” (night). b. the lower line indicates on the left-hand side the current boiler water temperature, and on the right-hand side the time. If the button is pressed briefly, the following data may be viewed in the following order: Press 1 x T1 supply temperature in the system Press 2 x T3 tap water temperature Press 3 x T4 return temperature in the system Press 4 x T5 water, if connected, or the maintained temperature of the built-in tap water exchanger of the boiler Press 5 x T6 outside temperature Press 6 x Room 1 - heat demand value of connected room unit Press 7 x Speed 1 - fan speed Press 8 x Pump - % pump speed in relation to maximum

Only the values of connected components are shown. 24.4 Menu - reset button

A pressure operated switch activated by pressing with finger until sensor below casing facia clicks or display changes. This button when pressed allows: Access to 3 layer menu programming options. Access to current boiler status displays. Confirms an entry when programming control. Reset the boiler after lockout. For meaning of lockout “FLASHING” display please refer to installer manual. 24.5 Summer winter button

Advances (scrolls forwards through menu and programming options). Increases a value in the LCD display. Sets boiler control to either summer (hot water only) or winter (hot water and heating both on mode)

24.6 Engineers button

Reverses (scrolls backwards through menu and programming options). Reduces a value in the LCD display. Places appliance into engineers mode for servicing purposes. "-" and "chimney sweep" symbols

The "-" button is used in combination with the menu button for programming purposes. The "chimney sweep" symbol (meant for the fitter). Press once: The unit will operate continuously at 50%; sensors or room units will not switch it off, only the maximum control thermostat. This mode is meant for measuring emissions (CO, CO, NOx). Press twice: The unit can now operate at all loads, by pressing the "+" and "-" buttons if the menu button is also pressed seven times, the display will show the speed. This

EC 16~38 Installation Manual page 35

Page 36: Variable Controlled Output (VCO) Solar Compatible jjjjj ...boilermanuals.org.uk/boilers/Eco Hometec/EC16,22,31... · eco hometec Unit 11E Carcroft Enterprise Park Carcroft Doncaster

mode is used to set the gas valve, both at minimum and at maximum load. 24.7 Test button

Checks overheat safety feature. When the burner is on and the button depressed, the burner will shut down when button released, the unit will start up again. . If the unit does not switch off, the wiring harness must be checked for short circuits, or the maximum thermostat must be replaced. Checks pump function. When the burner is off and the button depressed, the pump will run at 100% speed for approx 2 seconds. 24.8 General

To access the programming mode for times, temperatures, etc., the "Menu" button must be depressed for 3 seconds the screen will briefly display “-MENU-“ and display a menu option. Use the "+" and "-" buttons to scroll through the various options and the "MENU" button to select and confirm changes. 25. Menu options 25.1 Party

This function allows you to extend the current heating period. To access the party option press the “-MENU-“ button once and “____hours” will flash on the screen, press “+” or “-“ to enter a value then press “-MENU-“ button once to confirm entry. After expiry of the extension time set, the night-time temperature will start; if the lower night temperature had already started at the time of setting the party time, the daytime temperature will be obtained for the duration of the time set, after which the night-time temperature will be resumed. Range 0 – 24 hours. Default 0 hours. 26. User programming 26.1 Hot Water Temperature

For S type appliances (COMBIS) this function allows you to select the maximum hot water temperature. For H and HS type appliances connected to hot water cylinder where temperature control is provided with a sensor (available form eco hometec) this

function allows you to select the maximum temperature for the water in the cylinder. To access the “TEMP DHW” option press the "MENU" button until “_____” oC flashes on the screen. press “+” or “-“ to enter a value then press “-MENU-“ button once to confirm entry. Temperature range 40 - 60oC. Default 60oC. 26.2 Day temperature function

When the boiler is set up for outside temperature control (with or without a room thermostat or room unit) adjusting this setting raises or lowers the heating curve. This has the effect of increasing or lowering the boiler water temperature and ultimately increasing or lowering the room temperatures as the cooler or warmer water circulates through the heat emitters. Raising or lowering the building ambient temperature is possible without adjusting the setting of the room thermostat or room unit. If the boiler is set up to work without outside temperature reference then the feature has no function. To access press "MENU" button as before then press “+” or “-“ to enter a value then press “-MENU-“ button once to confirm entry. The default value for this setting is 20oC 26.3 Time/day function

Having selected this function, there is a subprogram with two options: the correct time, in minutes To change the time press “-MENU-“ button once and the use the press “+” or “-“ to change the time then press “-MENU-“ button once to confirm entry. the day To change the day press “-MENU-“ button once and the use the press “+” or “-“ to set the day then press “-MENU-“ button once to confirm entry. 26.4 Setting the ch timer

When a RE2132 room unit is fitted the built in timer function takes priority over the boilers timer control. In this case the boiler timer should be set to 00.00 hours.

Page 36 eco hometec (uk) ltd.

Page 37: Variable Controlled Output (VCO) Solar Compatible jjjjj ...boilermanuals.org.uk/boilers/Eco Hometec/EC16,22,31... · eco hometec Unit 11E Carcroft Enterprise Park Carcroft Doncaster

This programme enables the setting of 3 time blocks (3 start and 3 end times) per day (24 hours) for higher and lower room temperatures. This menu has two submenus: a. the days of the week b. the start and end times of each block To access this function from the main menu display press “MENU” button for three seconds. You will arrive at “PARTY O HOURS” in the display. Press the “+” button three times to arrive at SET CH TIMER Press the "MENU" button once and the first display will be "Monday" use the "+" and "-" buttons to scroll through this submenu to reach the day you want to change. Having found the correct day, press the "MENU" button once to arrive at “CopySU>MO” ignore this and press the "+” button once to arrive at “SWITCH ON 1” “MO 00:00” Press the "MENU" button once and the hours “00” part of the display will start flashing. This sets the hour the heating will start for the first of three possible on times per day Adjust the hour by pressing the "+" and "-" buttons. When the correct time is displayed confirm by pressing "MENU" button once and the minutes part of the display “00” will start flashing. Adjust the minutes by pressing the "+" and "-" buttons. When the correct time is displayed confirm by pressing "MENU" button once. Press the "+” button once to arrive at “SWITCH OFF 1” “MO 00:00” This sets the hour the heating will switch off for the first of three possible off times per day. Adjust the hour by pressing the "+" and "-" buttons.

When the correct time is displayed confirm by pressing "MENU" button once and the minutes part of the display “00” will start flashing. Adjust the minutes by pressing the "+" and "-" buttons. When the correct time is displayed confirm by pressing "MENU" button once. Press the "+” button once to arrive at “SWITCH ON 2” “MO 00:00” Repeat as above to programme all 3 start and 3 end times If you wish to ignore any periods then simply enter "0.00". Please note due to the nature of the pre-programmed boiler software there may be a half-hour delay in the CH system start and off times. This period can be offset by adjusting the on and off times. e.g. if you leave the house at 10:00 then enter 9:30 and if you are returning at 12:.30 enter 12.00. Always confirm the times with the "MENU" button. Programming all periods - note: you may ignore any blocks by entering 00:00 with the exception of “SWITCH ON 1” and “SWITCH OFF 1” for which you must enter a real time. After you have programmed all three on and off period’s press the "+" button to arrive at “<-BACK” Press the MENU button and you will arrive at TUESDAY. Press the MENU button again and you will arrive at COPY “MO -> TU” You can now copy the previous days program onto the next day e.g. Mondays times to Tuesday by pressing MENU or alternatively program in new times by pressing “+” button and repeating the process described in the previous section. To copy the previous days program Press the "MENU" button, you arrive at: “MON -> TUESDAY” Press the "MENU" button once to copy and the display will change to “WEDNESDAY”. Press the "MENU" button, you arrive at: “TU -> WEDNESDAY”

EC 16~38 Installation Manual page 37

Page 38: Variable Controlled Output (VCO) Solar Compatible jjjjj ...boilermanuals.org.uk/boilers/Eco Hometec/EC16,22,31... · eco hometec Unit 11E Carcroft Enterprise Park Carcroft Doncaster

Press the "MENU" button once to copy and the display will change to “THURSDAY” Repeat the process until all day have been copied or changed as required and you arrive at <- BACK. To exit this second submenu, from <-BACK press "MENU" button once and you will arrive at SET HW TIMER From here you can either continue to programme the unit or return to the operating display menu by pressing “+” repeatedly until you arrive at <-BACK then exit by pressing menu. 26.5 Setting the HW timer

This programme enables the setting of 3 time blocks (3 start and 3 end times) per day (24 hours) for higher and lower temperatures of the supply of tap water. This menu has two submenus: a. the days of the week b. the start and end times of each block For programming, repeat as for section CH timer. During programmed off periods Combi models (‘S’ types) will maintain a minimum storage temperature of 40oC. For H and HS type appliances connected to hot water cylinder for this function to operate temperature control has to be provided with a sensor (available from eco hometec). When hot water temperature control is provided by a cylinder thermostat this function is not recognised. 26.6 Setting MR03 times

When a MR 03 secondary circuit control unit has been fitted then this programme enables the setting of 3 time blocks (3 start and 3 end times) per day (24 hours) for higher and lower temperatures for a second central heating circuit. Note unless a MR 03 is connected this function will not be seen. 26.7 Night-time lower 0oc.

This is used to programme the value for the night time set back temperature in relation to the room temperature during the day.

NOTE ! If the difference between the daytime temperature and night time setback temperature is considerable, the start time of the central heating unit must be set earlier than required to compensate. Statistically, it has been proven that a night time decrease of 5°C is best; if a lower night-time temperature is set, heating in the morning requires too much energy. With “SETBACK” displayed on the screen press "MENU" button until “_____” oC flashes on the screen. press “+” or “-“ to enter a value then press “-MENU-“ button once to confirm entry. 26.8 Holiday function

Use the "+" and "-" buttons to set the number of days of the holiday period. During this period, the night time temperature will be maintained, while the tap water temperature will be set at a minimum of 20°C. If you are away for an extended period then to save energy adjust the night time temperature to 10°C. After the number of days has expired, the unit will start operating according to the clock programme set. Remember when you return to re-adjust the night time temperature to it’s original setting. Having completed the setting, press the "MENU" button to confirm the new value. 26.9 Installer

This function is for the service engineer only and is code protected.

Page 38 eco hometec (uk) ltd.

Page 39: Variable Controlled Output (VCO) Solar Compatible jjjjj ...boilermanuals.org.uk/boilers/Eco Hometec/EC16,22,31... · eco hometec Unit 11E Carcroft Enterprise Park Carcroft Doncaster

The Main Menu contains the following sections: TTaabbllee 1122 PPrrooggrraammmmiinngg FFuunnccttiioonnss Programme Number Programme Name Setting Range - MENU - 1 Party 0-24 hours 2 Hot Water Temperature 40 - 60°C 3 Day Temperature 10 – 30°C 4 Time / Day Mon-Sun 0.00 – 24.00 5 Set Central Heating Timer 3 x time blocks 6 Set Hot Water Timer 3 x time blocks 7 Set Mixing Valve Timer 3 x time blocks 8 Night Setback

Temperature 0 - 10°C less than

daytime 9 Service In 365 Days 10 Holidays 0 – 99 days 11 Installer access code 21 12 Back 27. Installer Programming A number of programming options are provided for the installer. These can only be accessed and programmed by means of a code. If this code is entered (21) the following parameters can be changed: TTaabbllee 1133 IInnssttaalllleerr FFuunnccttiioonnss Programme No. Programme name Setting range 1 Heating plan at +20°C outside temperature 0 - 40°C 2 Heating plan at -15°C outside temperature 10 - 85°C 3 * Minimum pump speed 20 - 50% 4 * Maximum pump speed 50 - 100% 5 Flow Temp at +20°C outside for secondary circuit 0 - 40°C 6 Service counter 0 - 1500 days 7 Pump continuous 0 or 1 8 ECO/ECO 9 Post running of pump after hot water demand 0 – 5 minutes 10 Post running of pump after central heating demand 0 – 5 minutes 11 Minimum output Hot Water supply 20 – 50% 12 Maximum output Hot Water supply 20 – 100% 14 Maximum output Central Heating 20 – 83% 15 Function 16 Back * can only be set if an outside temperature sensor has been installed. * can only be set if a modulating pump has been installed.

EC 16~38 Installation Manual page 39

Page 40: Variable Controlled Output (VCO) Solar Compatible jjjjj ...boilermanuals.org.uk/boilers/Eco Hometec/EC16,22,31... · eco hometec Unit 11E Carcroft Enterprise Park Carcroft Doncaster

28. Outside Temperature Control The weather compensating factory settings are as figure 30 below.

Figure 30 Weather Compensation

The flow temperatures are achieved by setting the required function number. See above. The relationship between flow temperature and outside temperature may be changed but the limiting factor will be the function number setting and corresponding flow temperature.. 28.1 Flow Temperature at + 20°C

Setting the flow temperature when outside air temperature is + 20°C. When control by outside air temperature is required the relationship between the outside temperature and the flow temperature can be changed. This line can be drawn between two points (- 1°C and + 20°C outside air temperature). Two temperatures, the flow temperature and the outside temperature define each point. When the outside air temperature reaches 20°C then normally no heating would be necessary and the setting should be 20°C adjust if necessary. Confirm by pressing the "MENU" button

Figure 31 O/T Ctrl Flow temp 85oC.

Figure 32 O/T Ctrl Flow temp 70oC

Figure 33 O/T Ctrl Flow temp 50oC

Page 40 eco hometec (uk) ltd.

Page 41: Variable Controlled Output (VCO) Solar Compatible jjjjj ...boilermanuals.org.uk/boilers/Eco Hometec/EC16,22,31... · eco hometec Unit 11E Carcroft Enterprise Park Carcroft Doncaster

28.2 Outside Temp. Control at - 1°C

Setting the flow temperature when outside air temperature is -1°C Enter here the flow temperature at -1°C outside temperature. The flow temperature is normally dependent on the size of the radiators and the calculated mean water temperature (generally 80°C). The limiting factor will be the function number setting. Confirm by pressing the "MENU" button. The supply temperature will automatically adapt to any changes in the outside temperature in relation to this outside temperature. 28.3 Minimum pump speed

If a modulating pump has been installed in the boiler, this function can be used to set the minimum pump speed. Normally, this value is 38%, but if the system resistance is high the minimum value must be set higher. Use the "+" and "-" buttons to change the minimum percentage. Confirm by pressing the "MENU" button. 28.4 Maximum pump speed

Normally the pump speed is 100%; if the water velocity or the noise from the radiators is too high, it is recommended to decrease the speed, taking into account the radiators that are furthest from the boiler must still maintain a sufficient flow. 28.5 Flow temperature secondary circuit

When a secondary circuit control has been connected (MR 03 available from eco hometec) to the boiler, the heating curve between the flow temperature of this circuit has to be set. Enter the required flow temperature when outside air temperature is + 20°C, normally no heating would be necessary and the setting should be 20°C adjust if necessary. The flow temperature -1°C is set at the MR 03 control unit.

28.6 Service counter

The boiler programme has a service counter, which is programmed at 365 days; after this period the message: "INSPECTION" appears. No other displays are shown until the fitter has reset the value of 365 days, or a different number of days, by pressing the "+" button. If necessary, this message can be removed from the system. 28.7 Pump continuous

Pressing the "+" button will cause the pump to operate continuously, except if the Summertime Mode is selected. Pressing "-" indicates that a pump switch is present. 28.8 Eco/eco+

If a modulating pump has been installed, the pump will modulate automatically in order to maintain the 20°C difference between the supply and return water temperatures. After heating in the morning, this modulation will only start after the desired supply temperature has been reached. If the resistance in the system is high, it is often desirable to obtain a higher pump pressure: if "ECO" is selected, the pump will start modulating when a return temperature of 50°C or higher has been reached. In the "ECO+" mode, the pump will modulate at any water temperature, with the exception of the heating cycle in the morning. 28.9 Post running of pump after HW

This function is used to set the post running time for the pump after the boiler has reached the required temperature. The default is 2 minutes, unless there is a demand from the CH system. 28.10 Post running of pump after CH

This function is used to set the post running time for the pump after the boiler has been switched off. The default is 1 minute.

EC 16~38 Installation Manual page 41

Page 42: Variable Controlled Output (VCO) Solar Compatible jjjjj ...boilermanuals.org.uk/boilers/Eco Hometec/EC16,22,31... · eco hometec Unit 11E Carcroft Enterprise Park Carcroft Doncaster

28.11 Minimum DHW Capacity

Using this function the default setting can be changed. In certain locations at low fan speeds the influence of the wind across the flue terminal outlet can lead to flame lift. The minimum fan speed should be increased until burner pressure is equalised. This minimum is also the minimum output for central heating. 28.12 Maximum DHW Capacity

If the boiler starts to cycle during how water production then a lower value could be set. However due to the boilers modulating control this is rarely necessary. 28.13 Maximum CH capacity

If the boiler starts to cycle when in heating mode then a lower value could be set. However due to the boilers modulating control this is rarely necessary.

Page 42 eco hometec (uk) ltd.

Page 43: Variable Controlled Output (VCO) Solar Compatible jjjjj ...boilermanuals.org.uk/boilers/Eco Hometec/EC16,22,31... · eco hometec Unit 11E Carcroft Enterprise Park Carcroft Doncaster

28.14 Function Setting

This “FUNCTION” number has to be set ALWAYS Outside temperature controlled without mixing circuit Function No. Room Temp Control Max Flow Temperature

1 RE 2132 55°C 2 RE 2132 70°C 3 RE 2132 85°C 4 240v Room Stat 55°C 5 240v Room Stat 70°C 6 240v Room Stat 85°C 7 TRV’s 55°C 8 TRV’s 70°C 9 TRV’s 85°C

Outside temperature controlled with mixing circuit Function No. Room Temp Control Max Flow Temperature

10 With two RE 2132 70°C primary 11 With two RE 2132 85°C primary 12 With one RE 2132 70°C primary 13 With one RE 2132 85°C primary 14 240v Room Stat 70°C primary 15 240v Room Stat 85°C primary 16 TRV’s 70°C primary 17 TRV’s 85°C primary

Room temperature controlled without mixing valve Function No. Room Temp Control Max Flow Temperature

18 RE 2132 55°C 19 RE 2132 70°C 20 RE 2132 85°C 21 240v Room Stat 55°C 22 240v Room Stat 70°C 23 240v Room Stat 85°C

Room temperature controlled with mixing valve Function No. Room Temp Control Max Flow Temperature

24 With two RE 2132 70°C primary 25 With two RE 2132 85°C primary 26 With one RE 2132 70°C primary 27 With one RE 2132 85°C primary 28 240v Room Stat 70°C primary 29 240v Room Stat 85°C primary

EC 16~38 Installation Manual page 43

Page 44: Variable Controlled Output (VCO) Solar Compatible jjjjj ...boilermanuals.org.uk/boilers/Eco Hometec/EC16,22,31... · eco hometec Unit 11E Carcroft Enterprise Park Carcroft Doncaster

Without room unit, thermostat or outside temperature control, constant flow temperatures without a mixing or secondary circuit. Function No. Room Temp Control Max Flow Temperature 30 None 55°C 31 None 70°C 32 None 85°C Without room unit, thermostat or outside temperature control, constant flow temperatures with a mixing or secondary circuit. Function No. Room Temp Control Max Flow Temperature 33 None 70°C primary 34 None 85°C primary eco hometec cascade manager KKM2 Settings (for controlling up to nine boilers) Function No. Cascade manager Max Flow Temperature 35 KKM2 CH temp on KKM2 Analogue cascade manager with signal 0…3 Volts. Function No. Cascade manager Max Flow Temperature 36 Analogue 0…3 Volts CH temp on manager The following function numbers are valid when a pump is used to load the hot water cylinder Outside temperature controlled without mixing circuit Function No. Room Temp Control Max Flow Temperature 37 RE 2132 55°C 38 RE 2132 70°C 39 RE 2132 85°C 40 240v Room Stat 55°C 41 240v Room Stat 70°C 42 240v Room Stat 85°C

TRV’s 55°C 44 TRV’s 70°C 45 TRV’s 85°C

43

Outside temperature controlled with mixing circuit Function No. Room Temp Control Max Flow Temperature 46 With two RE 2132 70°C primary 47 With two RE 2132 85°C primary 48 With one RE 2132 70°C primary 49 With one RE 2132 85°C primary 50 240v Room Stat 70°C primary 51 240v Room Stat 85°C primary 52 TRV’s 70°C primary 53 TRV’s 85°C primary

Page 44 eco hometec (uk) ltd.

Page 45: Variable Controlled Output (VCO) Solar Compatible jjjjj ...boilermanuals.org.uk/boilers/Eco Hometec/EC16,22,31... · eco hometec Unit 11E Carcroft Enterprise Park Carcroft Doncaster

Room temperature controlled without mixing valve Function No. Room Temp Control Max Flow Temperature 54 RE 2132 55°C 55 RE 2132 70°C 56 RE 2132 85°C 57 240v Room Stat 55°C 58 240v Room Stat 70°C 59 240v Room Stat 85°C Room temperature controlled with mixing valve Function No. Room Temp Control Max Flow Temperature 60 With two RE 2132 70°C primary 61 With two RE 2132 85°C primary 62 With one RE 2132 70°C primary 63 With one RE 2132 85°C primary 64 240v Room Stat 70°C primary 65 240v Room Stat 85°C primary Without room unit, thermostat or outside temperature control, constant flow temperatures without a mixing or secondary circuit. Function No. Room Temp Control Max Flow Temperature 66 None 55°C 67 None 70°C 68 None 85°C Without room unit, thermostat or outside temperature control, constant flow temperatures with a mixing or secondary circuit. Function No. Room Temp Control Max Flow Temperature 69 None 70°C primary 70 None 85°C primary eco hometec cascade manager KKM2 Settings (for controlling up to nine boilers) Function No. Cascade manager Max Flow Temperature 71 KKM2 CH temp on KKM2 Analogue cascade manager with signal 0…3 Volts. Function No. Cascade manager Max Flow Temperature 72 Analogue 0…3 Volts CH temp on manager

EC 16~38 Installation Manual page 45

Page 46: Variable Controlled Output (VCO) Solar Compatible jjjjj ...boilermanuals.org.uk/boilers/Eco Hometec/EC16,22,31... · eco hometec Unit 11E Carcroft Enterprise Park Carcroft Doncaster

Figure 34 Internal Wiring

Page 46 eco hometec (uk) ltd.

Page 47: Variable Controlled Output (VCO) Solar Compatible jjjjj ...boilermanuals.org.uk/boilers/Eco Hometec/EC16,22,31... · eco hometec Unit 11E Carcroft Enterprise Park Carcroft Doncaster

29. Commissioning 29.1 Electrical Checks

A “Preliminary Electrical System Check” should be carried out to ensure earth continuity, short circuit, polarity and resistance to earth using a suitable multi meter. 29.2 Gas Supply

Check the gas installation and purge the supply in accordance with current Gas Safety Regulations.

The gas valve fitted to the boiler is not designed to withstand pressures in excess of 60 mbar. When carrying out the pressure test on the service pipe-work it is essential that the gas cock fitted to the boiler is in the closed position, failure to do so will result in serious damage to the boiler. If using LPG, care should be taken to ensure that the storage tank has been correctly vented. 29.3 Connection to Pipe-work

The boiler is a low water content unit. When connecting to an existing installation it is important that old system deposits are removed and are not allowed to contaminate the appliance. 29.4 Water Treatment

In order to protect and prolong the working life of the appliance, it is important the general condition of older systems is carefully considered. The removal of debris, flux residue, grease, metal swarf etc. from new systems and any rust , black magnetic iron oxide sludge and lime-scale from old systems is essential. Consider high pressure flushing to remove all debris in badly contaminated systems.

Fit in-line filters for full protection. All installations should be treated and maintained with Fernox MB1 at a concentration of 4%.

29.5 Flushing System Pipe-work

Before the final flow and return connections are made to the boiler, the system must be thoroughly flushed. Ensure that all radiator valves are open. Flush the system with clean water until the discharge runs clear. Make good final connections to boiler. 29.6 Filling and Venting the System

Using a suitably approved filling loop connected to the incoming mains cold water supply, fill the system. The correct filling pressure is between 1 and 2 bar. Depending on the type of unit, the following steps must be completed: Venting is achieved automatically after switching on the appliance or after a reset. The boiler control has a special start-up programme for venting the unit. This programme is started when the unit is powered for the first time and there is a heat demand present. This start-up venting programme takes 1 minute to complete. This feature however does not remove the need for traditional venting techniques and the following venting procedure should be completed in all cases. The boiler has a manual bleed valve located on the top right hand side along with a short piece of clear plastic hose. Open the manual bleed valve and run water into hose pipe until air bubbles stop. All the air should be vented via this point. If necessary, this bleeder can be replaced with an automatic air vent. Check the filling pressure of the unit shortly after start-up, add water if necessary in order to maintain the correct pressure. Filling is only complete when the boiler, and the heating system are completely vented.

EC 16~38 Installation Manual page 47

Page 48: Variable Controlled Output (VCO) Solar Compatible jjjjj ...boilermanuals.org.uk/boilers/Eco Hometec/EC16,22,31... · eco hometec Unit 11E Carcroft Enterprise Park Carcroft Doncaster

The heating system should be fitted with manual air vents at all high points. ‘S’ Type 38kW Combination Boiler Only. The AQUA BOOSTER TANK IS VENTED VIA AN AIR VENT MOUNTED ON THE TOP RIGHT HAND SIDE OF THE AQUABOOSTER PLEASE ENSURE YOU REMOVE ALL THE AIR FROM THIS POINT DURING VENTING PROCEDURES. CHECK TO MAKE SURE AN EXPANSION TANK AND A 3BAR PRESSURE RELIEF VALVE HAS BEEN FITTED TO THE SYSTEM AND THE DISCHARGE PIPE TERMINATES TO A SAFE LOCATION Check for water soundness at design operating temperature. After commissioning, the system should be thoroughly flushed whilst system water is still warm. Drain down system and make good to any leaks. Refill, add a suitable corrosion inhibitor Fernox MB 1 at 4%. For further information about filling the system contact the eco hometec Technical Support Department. 30. Combustion Ratio Due to the precise Variable Controlled Output of the boiler it is highly recommended that flue gas analysis equipment be used when setting up the burner. The setting up of the boiler using gas pressures should be used as a temporary or emergency measure only. 30.1 Commissioning NG and LPG

Measure the standing gas pressure at the measuring nipple on the gas valve. This should be done at test point (32) on the gas valve (see figure 35). Nominal pressure should be 20 mbar in the case of natural gas, and 37 mbar in the case of propane gas.

Turn up the boiler controls to call for heat. Switch on the boiler, if the boiler fails to start check the LCD display for a flashing [FAULT CODE], if this occurs turn the adjusting screw (31) in the centre of the gas valve ½ a turn to the right and press the reset button. The boiler should now fire. After the boiler has fired and ran for five minutes press the flue emissions button with the chimney sweep icon twice. The status display will show the [partial load]. Using the "+" or "-" button, the fan speed can be increased or decreased. Keep pressing the "MENU" button until the fan speed is shown. To obtain the minimum load, press the "-" button until the minimum speed has been obtained. To obtain the maximum load, press the "-" button until the maximum speed has been obtained. If measuring is done for more than 10 minutes, the unit will return to automatic mode; press the chimney sweep button twice again for subsequent measurements TTaabbllee 1144 MMiinniimmuumm && MMaaxxiimmuumm ffaann ssppeeeeddss Unit 16 23 31 38 Min 900 900 900 1050 Max 6000 6000 6000 7500 31. Setting the Maximum CO2

Value Press the flue emissions button with the chimney sweep icon twice. To obtain the maximum load, press the "-" button until the maximum fan speed has been obtained. (See table 14). The boiler will now operate at 100% output for approximately 10 minutes. From the measuring point located at the top right hand corner of the heat exchanger remove the plastic sealing nut and fibre washer. Insert the probe of the gas

Page 48 eco hometec (uk) ltd.

Page 49: Variable Controlled Output (VCO) Solar Compatible jjjjj ...boilermanuals.org.uk/boilers/Eco Hometec/EC16,22,31... · eco hometec Unit 11E Carcroft Enterprise Park Carcroft Doncaster

analyser 2cm into the heat exchanger and measure the CO2

level. The burner will have a red surface. If necessary fine tune using the adjusting screw 4 Q Max until the required CO2 (see table 15) value is reached. Turn the screw clockwise to lower the CO2 reading and anti clockwise to increase the CO2. Remember to allow 2 minutes for the analyser to respond to any adjustments. Figure 35 Gas valve adjustments

To obtain the minimum load, press the "-" button until the minimum speed has been obtained Measure the CO2 level. (This reading should be 9.2% for NG and 11.0 for LPG). The colour of the flame should be red/blue with small sharp cones and without any flame lifting. If necessary fine tune using the adjusting screw 3 Q Min until the CO2 value is reached. Turn the screw anti clockwise to lower the CO2 reading and clockwise to increase the CO2.

Remember to allow 2 minutes for the analyser to respond to any adjustments.

TTaabbllee 1155 CCOO22 OOuuttppuuttss

Gas Type Natural LPG Injector Dia. Min None 5.7mm Wo (MJ/m3) 15.0 24.3 CO2 % partial load

9.0 – 9.5 11.5 – 12.0

CO2 % full load 8.5 – 8.8 15.5 – 11.0

C0 ppm partial load

<15 <20

C0 ppm full load <50 <150 The measured CO2 and Co values are for partial load (20%) and full load (100%) with the casing removed. When the setting is correct press the flue emissions test button once and the boiler will revert to normal operation. 31.1 Flue System Check

In order to examine the flue pipe sealing it is essential that an O2 or CO2 reading is taken from the 8mm plastic pipe that should be positioned from the Grey Vent/Flue adapter led down and through the bottom boiler plate. The flue seal is satisfactory when the CO2 value is no more than 0.2% and the O2 value no more than 20.6% 31.2 STB Test Button (Green).

This button is used to test the correct operation of the overheat thermostat (high limit thermostat). 32. Diagnostics 32.1 Control panel

The control panel of the unit has a LCD screen displaying two lines of data. This screen provides information about the operation of the boiler it displays operation messages (non-flashing) and fault messages (flashing display). The first line contains textual information on the operating status of the unit. It shows:

EC 16~38 Installation Manual page 49

Page 50: Variable Controlled Output (VCO) Solar Compatible jjjjj ...boilermanuals.org.uk/boilers/Eco Hometec/EC16,22,31... · eco hometec Unit 11E Carcroft Enterprise Park Carcroft Doncaster

TTaabbllee 1166 LLCCDD DDiissppllaayy ‘‘NNOONN FFLLAASSHHIINNGG’’ SSttaattuuss DDiissppllaayy MMeessssaaggeess ‘‘NNOONN FFLLAASSHHIINNGG’’ IDLE This display shows that there is no heat demand CH OPERATION The boiler is operating in central heating mode TAP WATER OPERATION The boiler is operating to produce DHW 10MIN. PARTIAL LOAD The boiler is operating in chimney sweep mode for 10 minutes In the following cases, there may be a heat demand, but the burner is not working, for one of the following reasons: TTaabbllee 1177 LLCCDD ‘‘NNOONN FFLLAASSHHIINNGG’’ bbuurrnneerr ooffff SSttaattuuss DDiissppllaayy MMeessssaaggeess ‘‘NNOONN FFLLAASSHHIINNGG’’ wwiitthh tthhee bbuurrnneerr ooffff.. MAXIMUM WATER TEMP The boiler water temperature has reached the set point FAN OFF-ON The fan has switched off. Unit will try to reset automatically. FAN TOO LOW Detected fan speed to low. Unit will try to reset automatically.

Check wiring terminals on top of transformer FLAME IDENTIFICATION Flame detected. . Unit will try to reset automatically. BLEED Boiler going through automatic venting cycle 33. Fault Finding. Fault Indicator (flashing display) To a certain extent the boiler will attempt to automatically overcome some of the faults that occur. For example, it will attempt 4 ignition sequences before going to lock out. In situations where it has not been successful, the boiler will lock out and can only be re-started by pressing the manual (Red) reset button. When in lock out mode, the error is displayed in the LCD display as a flashing message. The following list indicates the messages shown and the descriptions of the faults. The numbers shown in the left hand column, suggest the possible cause. By using the numbered lists attached, the cause of the fault can be quickly identified and a repair effected.

Page 50 eco hometec (uk) ltd.

Page 51: Variable Controlled Output (VCO) Solar Compatible jjjjj ...boilermanuals.org.uk/boilers/Eco Hometec/EC16,22,31... · eco hometec Unit 11E Carcroft Enterprise Park Carcroft Doncaster

TTaabbllee 1188 FFaauulltt DDiissppllaayy FFLLAASSHHIINNGG Display message FLASHING

Type of fault Check table row number

STB- supply Maximum flow temperature has been reached 2,4,5,21,23,24,29,30 STB- fluegas Maximum flue gas temperature has been

reached 4,5,23,24,29,33

Fanspd high Fan speed is too high 7,8,9,39,40 Fanspd low Fan speed is too low 7,8,9,39,40 Ignit fault No flame after 4 attempts 10,11,16,18,22,25 No flame Flame failed during operation 11,12,16,22,25,2632,

44 False flame False flame detection 18,35 S1 disconnect Sensor or cable interrupted 3,41,42,43 S3 disconnect Sensor or cable interrupted 3,41,42,43 S4 disconnect Sensor or cable interrupted 3,41,42,43 S7 disconnect Sensor or cable interrupted 3,41,42,43 Program end Sensor or cable interrupted 3,41,42,43 Gasvalve No phase connection for gas valve 34,20 Softw Fault A software error has occurred 34 Reset-Key Reset button is stuck 34 Eeprom EEPROM test failed 34 Intern fault Test fault In addition, there is a number of faults that cannot be reported by means of a textual display: TTaabbllee 1199 NNoonn DDiissppllaayy FFaauullttss aanndd EErrrroorrss water inside casing leak load is too low discharge resistance Fan speed CO-content is too high bad combustion CO2 % is too low too little gas or too much air CO2 % is too high too much gas tap water temperature too low leaking three-way valve to little tap water blockage, lime scale deposit no CH operation leaking hot water pipe or dripping tap Display has illegible text moisture problems in unit controller, or an incorrect

ignition plug used on the electrode Water pressure constantly low leak in system, or internal leak in expansion vessel

EC 16~38 Installation Manual page 51

Page 52: Variable Controlled Output (VCO) Solar Compatible jjjjj ...boilermanuals.org.uk/boilers/Eco Hometec/EC16,22,31... · eco hometec Unit 11E Carcroft Enterprise Park Carcroft Doncaster

TTaabbllee 2200 RReeaassoonnss FFoorr EErrrroorr DDiissppllaayy Fault Suggested Remedy 1 room thermostat connected incorrectly check or replace cable 2 room thermostat fails to switch off Replace room thermostat or replace cable 3 Relevant sensor short-circuits in cable or

internally Replace sensor or identify fault in cable

4 Pump not running; or sticks

Try to release pump shaft or replace pump power unit

5 Water pressure in CH installation is too low Top up water and find leak, also check for internal leak in expansion vessel

6 Water pressure in CH installation is too high

Too much water added, check expansion vessel pressure, or replace expansion vessel

7 Fan not connected (plug not inserted) Install connector 8 Fan is contaminated or dirty Clean fan blades 9 Fan is defective Replace fan 10 Gas tap has not been opened Open gas tap 11 Gas pressure is too low Check pipes and gas meter 12 Diameter gas pipe is insufficient Modify gas pipe 13 Fuse A1 defective Replace fuse 14 Fuse A2 defective Replace fuse 15 Fuse A3 defective Replace fuse 16 Gas valve setting high/low incorrect Set up gas valve with gas analyser 17 Gas valve has no or incorrect electrical

connection Use the wiring diagram to check the wiring, check the gas valve connection, check for any moisture

18 Ignition cable not connected correctly Check cable for short circuit, overheating, too close to or crushed by casing

19 Transformer defective Replace transformer 20 Connector to gas valve not connected, or

moisture inclusion Moisture inclusion, check the cable sockets, which must be inserted into connectors properly, check position of the cable socket, set if necessary, before moving connector

21 Pump connector not connected correctly Check whether the connector(s) fit together properly, with the appropriate pressure

22 Syphon blocked Open the flushing pipe (bottom left of the back panel) by taking the cap off. Hold a bowl underneath to collect any water that may escape. Pinch pipes to both to the upper left and the upper right. Rinse sypon trap. If necessary, take the burner unit from the unit and pour water into the heat exchanger to rinse the syphon.

23 Open and close manual bleed valve after bleeding

Bleed and vent as required

24 Three-way valve contaminated Isolate and drain boiler water. Disassemble the three-way valve by tilting the mounting springs 90°. Remove the motor by pulling the hairpin spring from the house and inspect the three connecting feet of the three-way valve.

25 Too much resistance in the flue system or flue system blocked

Check the supply and discharge pipes for blockages

Page 52 eco hometec (uk) ltd.

Page 53: Variable Controlled Output (VCO) Solar Compatible jjjjj ...boilermanuals.org.uk/boilers/Eco Hometec/EC16,22,31... · eco hometec Unit 11E Carcroft Enterprise Park Carcroft Doncaster

26 Flue system leaks into the air supply system or re-circulation of flue gases in concentric flue

Check the air supply and flue system

27 Supply system leaks in See 26 28 Flow limiter is contaminated Remove the cold-water connection from the

unit, remove the flow limiter and clean it 29 Heat exchanger is blocked Remove the heat exchanger from the unit

by releasing the mounting springs (2) and the clamp at the front. Use pressurised air to blow the exchanger clean; if necessary, rinse with a slightly (10%) hydrochloric acid solution

30 High limit thermostat defective Replace the maximum thermostat 31 Maximum load is too high Check the minimum setting of the unit and

the nozzle for a proper diameter. 32 Incorrect nozzle Replace by correct nozzle 33 Flue gas thermostat defective Replace 34 Controller defective Replace entire boiler control box 35 Ignition electrode incorrect Replace 36 Moisture on gas valve cables Dry, if necessary using hot air (hair dryer)

and check for proper functioning; replace if necessary

37 Moisture on electronics box See 36 38 Moisture in pump wiring See 36 39 Moisture on fan or and/or connections Remove the connection and dry by blowing

or using hair dryer 40 Fan connector incorrectly connected Connector must point in the direction of the

outside of the ventilator and one side must fit into the slot in the printed circuit

41 Connector incorrectly connected Check connectors and fit into one another properly

42 Cable damaged Check cables for possible damage or kinks 43 Sensor defective Check cable pipe connections

44 Flue gas re-circulation from behind heat exchanger

Check heat exchanger seal on flue gas box, replace if necessary.

EC 16~38 Installation Manual page 53

Page 54: Variable Controlled Output (VCO) Solar Compatible jjjjj ...boilermanuals.org.uk/boilers/Eco Hometec/EC16,22,31... · eco hometec Unit 11E Carcroft Enterprise Park Carcroft Doncaster

34. Handing the boiler over 34.1 Customer Familiarisation

Before leaving the installation, it is important to familiarise the customer with the operating principles of the boiler. Their attention should also be drawn to the safety precautions. Familiarise the customer with the control panel layout. 35. Annual Servicing

It is a condition of the boiler warranty that all servicing and maintenance be carried out annually by eco hometec approved engineers only. When the word [SERVICE] is displayed in the LCD display on the control panel, a full service of the unit is required. A service has to be carried out when : The appliance tells so by the LCD that inspection is needed; Every 12 months Before maintenance is started the appliance has to be inspected. 35.1 Service Inspection

The following is the eco hometec approved service schedule: Interview with the user about possible problems or complaints with the appliance or it’s use. The remarks of the user should be taken seriously and the reason for any complaints or anomalies should be found and rectified. Check the water pressure of the system. System pressure of the installation should be between 1 and 2 bar; any cause for pressure loss should be found and rectified. Lift the casing of the boiler and inspect all pipes for water leaks or water damage. Sweating joints or leaks should be repaired immediately. Inspect the top of the boiler for water-leak or traces or evidence of water leaking from

the 125mm air inlet tube or the automatic air separator. The cause of any water or moisture entering the boiler through the 125mm air inlet tube should be found and rectified. Check the air and flue duct for proper alignment, and the air and flue duct terminal. Set the appliance burning at maximum output and measure the CO2 . Adjust the maximum setting of the gas valve as required. Set the appliance burning at medium output and measure the CO2. Adjust the setting of the gas valve as required. Pay attention to the sound of the circulator. Check for air in the shaft and vent if required. For the comibi ‘S’ boilers, measure by a fully-opened tap, the flow rate and the temperature of the DHW. If the flow rate is less than 9 litres/min check the mains cold water supply. If the mains pressure is not the cause, the flow restrictor needs to be checked for blockages. If the flow restrictor is clean then there could be calcium in the AQUA-BOOSTER. The AQUA-BOOSTER needs to be replaced. Due to it’s construction, cleaning of the heat exchanger is not possible, one might think it is, but experience has shown that after cleaning, the lifetime of the component is very short, making cleaning uneconomical. Check, during hot water supply, the temperature of the flow to the central heating system. If during the hot water cycle the flow to the c/h system goes up in temperature, this indicates that the three-way valve has an internal leak and needs to be cleaned. The boiler needs to be drained and the three-way valve can be dismounted. Remove the ignition cable and then disconnect the fan. Take off the burner by removing 6 x M6 nuts. Check the inside of the heat exchanger, look for any irregularities. When the SPIRANOX main heat exchanger has dirt on the inside of the elements, clean with a hard brush (no steel), or with lemon acid. Afterwards use a vacuum cleaner to remove all the dirt. The burner itself should never be cleaned.

Page 54 eco hometec (uk) ltd.

Page 55: Variable Controlled Output (VCO) Solar Compatible jjjjj ...boilermanuals.org.uk/boilers/Eco Hometec/EC16,22,31... · eco hometec Unit 11E Carcroft Enterprise Park Carcroft Doncaster

When the condensate water out of the cleaning tube of the syphon is dirty, the syphon requires cleaning. Rinse the syphon through the syphon flush connection or with the burner dismounted flush cold water through the syphon heat exchanger connection or with access to the flue, flush the heat exchanger and syphon through by pouring water down the 70mm inner flue duct.

15. After flushing ensure that the condense syphon is refilled with water, otherwise flue products may be passed through the condensate pipe-work into the building. Take off the plastic mixing box at the inlet side of the fan, inspect the fan impeller for damage. When the impeller of the fan is dirty every blade has to be carefully cleaned until the original plastic material is clearly visible. When dirt is left on the blades the fan will run out of balance and, due to the fast fan speeds (>6000 rpm), additional and unnecessary loads will be placed on the fan bearings significantly reducing the lifetime of the component. Check the distance of the electrode to the burner; this should be a 3mm ~ 4mm gap. Bend the electrode, without touching the burner surface, very carefully until a space of 3mm ~ 4mm is achieved. Check the seals on the gas connections and ensure that the gas service is sound by completing a gas soundness test. Check the wiring and fuse at the spur is no greater than 3amp. 35.2 Pre-preventative Maintenance

Depending on the result of the inspection, further action may be required to complete the pre-preventative maintenance schedule. Pre-preventative maintenance is a unique feature of all eco hometec boilers and is incorporated to further enhance their excellent reputation for reliability. The following components should be replaced on an hours run basis.

Connect the P.C. Notebook to the boiler. Following the instructions in the P.C servicing software down load a readout of the service log; pay particular attention to the various lockouts and re-ignitions. Look carefully at the service screen of the P.C. notebook and identify and replace any parts which have caused any problems. The pump ~ should be replaced after 50,000 running hours (the total of CH and HW on 50% load), or when the pump is noisy, especially when the running time is more than 40,000 hours, or if the pump is 5 years or older. The actuator on the three-way valve ~ should be replaced after 50,000 switches. The fan ~ after 40,000 running hours. 35.3 Service records

Complete the appliance service record, ask the user to sign it and hand them the second copy. Return the top copy to eco hometec and service company or service engineer to retain copy on file for their/your records. Complete an appliance service label and attach to underside of appliance case. 36. Decommissioning the boiler When decommissioning the boiler, precautions should be taken to avoid frost damage. Therefore it is essential that both the boiler and the central heating system are completely drained down. To do this remove the front casing and connect a hose to the central heating drain point. The system should be vented by opening the DHW valve and /or the manual air vent on the central heating circuit. Tag the boiler “DO NOT USE SYSTEM DRAINED” and remove the fuse at the isolating switch.

EC 16~38 Installation Manual page 55

Page 56: Variable Controlled Output (VCO) Solar Compatible jjjjj ...boilermanuals.org.uk/boilers/Eco Hometec/EC16,22,31... · eco hometec Unit 11E Carcroft Enterprise Park Carcroft Doncaster

37. User Instructions 37.1 Annual Servicing.

It is a condition of the boiler warranty that all servicing and maintenance be carried out annually by eco hometec approved engineers only. When the word [INSPECTION] is displayed in the LCD display on the control panel, a full service of the unit is required. A service has to be carried out when : The status display appears INSPECTION or

Every 12 months

37.2 Decommissioning the boiler.

When decommissioning the boiler, precautions should be taken to avoid frost damage. Therefore it is essential that both

the boiler and the central heating system are completely drained down. 37.3 Built-in clock

The appliance has a unique built-in 3 channel programmable time clock. This enables not only the setting of the heating times for various temperatures, but also the heating times for hot water. During programmed off periods Combi models (‘S’ types) will maintain a minimum storage temperature of 40oC. For H and HS type appliances connected to hot water cylinder for this function to operate temperature control has to be provided with a sensor (available from eco hometec). When hot water temperature control is provided by a cylinder thermostat this function is not available. For convenience it is possible to ignore the built in programmer and alternatively control the boiler using a remote programmer. Please check with your installer to confirm which option has been installed.

Figure 36 Boiler Control panel

Page 56 eco hometec (uk) ltd.

Page 57: Variable Controlled Output (VCO) Solar Compatible jjjjj ...boilermanuals.org.uk/boilers/Eco Hometec/EC16,22,31... · eco hometec Unit 11E Carcroft Enterprise Park Carcroft Doncaster

37.4 Boiler Control Panel

The boiler control panel incorporates the following features. 37.5 System water pressure

Informs user of current system water pressure. 37.6 On / off switch

Boiler isolating switch.

Always switch to the OFF position when working on the unit. 37.7 Lcd control display

The display has two lines: the upper line indicates the current operating status e.g HW DEMAND and either “S” (summer) or “W” (winter / “D” (day) or “n” (night). b. the lower line indicates on the left-hand side the current boiler water temperature, and on the right-hand side the time. If the button is pressed briefly, the following data may be viewed in the following order: Press 1 x T1 supply temperature in the system Press 2 x T3 tap water temperature Press 3 x T4 return temperature in the system Press 4 x T5 water, if connected, or the maintained temperature of the built-in tap water exchanger of the boiler Press 5 x T6 outside temperature Press 6 x Room 1 - heat demand value of connected room unit Press 7 x Speed 1 - fan speed Press 8 x Pump - % pump speed in relation to maximum

Only the values of connected components are shown. 37.8 Menu - reset button

A pressure operated switch activated by pressing with finger until sensor below casing facia clicks or display changes. This button when pressed allows: Access to 3 layer menu programming options. Access to current boiler status displays. Confirms an entry when programming control. Reset the boiler after lockout. For meaning of lockout “FLASHING” display please refer to installer manual. 37.9 Summer winter button

Advances (scrolls forwards through menu and programming options). Increases a value in the LCD display. Sets boiler control to either summer (hot water only) or winter (hot water and heating both on mode)

37.10 Engineers button

Reverses (scrolls backwards through menu and programming options). Reduces a value in the LCD display. Places appliance into engineer’s mode for servicing purposes.

37.11 Test button

Checks overheat safety feature. When the burner is on and the button depressed, the burner will shut down when button released, the unit will start up again. Checks pump function. When the burner is off and the button depressed, the pump will run at 100% speed for approx 2 seconds. 37.12 General

To access the programming mode for times, temperatures, etc., the "Menu" button must be depressed for 3 seconds the screen will briefly display “-MENU-“ and display a menu option. Use the "+" and "-" buttons to scroll through the various options and the "MENU" button to select and confirm changes.

EC 16~38 Installation Manual page 57

Page 58: Variable Controlled Output (VCO) Solar Compatible jjjjj ...boilermanuals.org.uk/boilers/Eco Hometec/EC16,22,31... · eco hometec Unit 11E Carcroft Enterprise Park Carcroft Doncaster

38. Programming Menu options 38.1 Party

This function allows you to extend the current heating period. To access the party option press the “-MENU-“ button once and “____hours” will flash on the screen, press “+” or “-“ to enter a value then press “-MENU-“ button once to confirm entry. After expiry of the extension time set, the night-time temperature will start; if the lower night temperature had already started at the time of setting the party time, the daytime temperature will be obtained for the duration of the time set, after which the night-time temperature will be resumed. Range 0 – 24 hours. Default 0 hours. 38.2 Hot Water Temperature

For S type appliances (COMBIS) this function allows you to select the maximum hot water temperature. For H and HS type appliances connected to hot water cylinder where temperature control is provided with a sensor (available form eco hometec) this function allows you to select the maximum temperature for the water in the cylinder. To access the “TEMP DHW” option press the "MENU" button until “_____” oC flashes on the screen. press “+” or “-“ to enter a value then press “-MENU-“ button once to confirm entry. Temperature range 40 - 60oC. Default 60oC. 38.3 Day temperature function

When the boiler is set up for outside temperature control (with or without a room thermostat or room unit) adjusting this setting raises or lowers the heating curve. This has the effect of increasing or lowering the boiler water temperature and ultimately increasing or lowering the room temperatures as the cooler or warmer water circulates through the heat emitters. Raising or lowering the building ambient temperature is possible without adjusting the setting of the room thermostat or room unit. If the boiler is set up to work without outside temperature reference then the feature has no function. To access press "MENU" button as before then press “+” or “-“ to enter a value then press “-MENU-“

button once to confirm entry. The default value for this setting is 20oC 38.4 Time/day function

Having selected this function, there is a subprogram with two options: the correct time, in minutes To change the time press “-MENU-“ button once and the use the press “+” or “-“ to change the time then press “-MENU-“ button once to confirm entry. the day To change the day press “-MENU-“ button once and the use the press “+” or “-“ to set the day then press “-MENU-“ button once to confirm entry. 38.5 Setting the ch timer

When a RE2132 room unit is fitted the built in timer function takes priority over the boilers timer control. In this case the boiler timer should be set to 00.00 hours. This programme enables the setting of 3 time blocks (3 start and 3 end times) per day (24 hours) for higher and lower room temperatures. This menu has two submenus: a. the days of the week b. the start and end times of each block To access this function from the main menu display press “MENU” button for three seconds. You will arrive at “PARTY O HOURS” in the display. Press the “+” button three times to arrive at SET CH TIMER Press the "MENU" button once and the first display will be "Monday" use the "+" and "-" buttons to scroll through this submenu to reach the day you want to change. Having found the correct day, press the "MENU" button once to arrive at

Page 58 eco hometec (uk) ltd.

Page 59: Variable Controlled Output (VCO) Solar Compatible jjjjj ...boilermanuals.org.uk/boilers/Eco Hometec/EC16,22,31... · eco hometec Unit 11E Carcroft Enterprise Park Carcroft Doncaster

“CopySU>MO” ignore this and press the "+” button once to arrive at “SWITCH ON 1” “MO 00:00” Press the "MENU" button once and the hours “00” part of the display will start flashing. This sets the hour the heating will start for the first of three possible on times per day Adjust the hour by pressing the "+" and "-" buttons. When the correct time is displayed confirm by pressing "MENU" button once and the minutes part of the display “00” will start flashing. Adjust the minutes by pressing the "+" and "-" buttons. When the correct time is displayed confirm by pressing "MENU" button once. Press the "+” button once to arrive at “SWITCH OFF 1” “MO 00:00” This sets the hour the heating will switch off for the first of three possible off times per day. Adjust the hour by pressing the "+" and "-" buttons. When the correct time is displayed confirm by pressing "MENU" button once and the minutes part of the display “00” will start flashing. Adjust the minutes by pressing the "+" and "-" buttons. When the correct time is displayed confirm by pressing "MENU" button once. Press the "+” button once to arrive at “SWITCH ON 2” “MO 00:00” Repeat as above to programme all 3 start and 3 end times If you wish to ignore any periods then simply enter "0.00". Please note due to the nature of the pre-programmed boiler software there may be a half-hour delay in the CH system start and off times. This period can be offset by adjusting the on and off times. e.g. if you leave the house at 10:00 then enter 9:30 and if you are returning at 12:.30 enter 12.00. Always confirm the times with the "MENU" button. Programming all periods - note: you may ignore any blocks by entering 00:00 with the

exception of “SWITCH ON 1” and “SWITCH OFF 1” for which you must enter a real time. After you have programmed all three on and off period’s press the "+" button to arrive at “<-BACK” Press the MENU button and you will arrive at TUESDAY. Press the MENU button again and you will arrive at COPY “MO -> TU” You can now copy the previous days program onto the next day e.g. Mondays times to Tuesday by pressing MENU or alternatively program in new times by pressing “+” button and repeating the process described in the previous section. To copy the previous days program Press the "MENU" button, you arrive at: “MON -> TUESDAY” Press the "MENU" button once to copy and the display will change to “WEDNESDAY”. Press the "MENU" button, you arrive at: “TU -> WEDNESDAY” Press the "MENU" button once to copy and the display will change to “THURSDAY” Repeat the process until all day have been copied or changed as required and you arrive at <- BACK. To exit this second submenu, from <-BACK press "MENU" button once and you will arrive at SET HW TIMER From here you can either continue to programme the unit or return to the operating display menu by pressing “+” repeatedly until you arrive at <-BACK then exit by pressing menu. 38.6 Setting the hw timer

This programme enables the setting of 3 time blocks (3 start and 3 end times) per day (24 hours) for higher and lower temperatures of the supply of tap water. This menu has two submenus: a. the days of the week b. the start and end times of each block

EC 16~38 Installation Manual page 59

Page 60: Variable Controlled Output (VCO) Solar Compatible jjjjj ...boilermanuals.org.uk/boilers/Eco Hometec/EC16,22,31... · eco hometec Unit 11E Carcroft Enterprise Park Carcroft Doncaster

For programming, repeat as for section CH timer. During programmed off periods Combi models (‘S’ types) will maintain a minimum storage temperature of 40oC. For H and HS type appliances connected to hot water cylinder for this function to operate temperature control has to be provided with a sensor (available from eco hometec). When a cylinder thermostat provides hot water temperature control this function is not recognised. 38.7 Setting MR03 times

When a MR 03 secondary circuit control unit has been fitted then this programme enables the setting of 3 time blocks (3 start and 3 end times) per day (24 hours) for higher and lower temperatures for a second central heating circuit. Note unless a MR 03 is connected this function will not be seen. 38.8 Night-time lower 0oc

This is used to programme the value for the night time set back temperature in relation to the room temperature during the day. NOTE! If the difference between the daytime temperature and night time setback temperature is considerable, the start time of the central heating unit must be set earlier than required to compensate.

Statistically, it has been proven that a night time decrease of 5°C is best; if a lower night-time temperature is set, heating in the morning requires too much energy. With “SETBACK” displayed on the screen press "MENU" button until “_____” oC flashes on the screen. press “+” or “-“ to enter a value then press “-MENU-“ button once to confirm entry. 38.9 Holiday function

Use the "+" and "-" buttons to set the number of days of the holiday period. During this period, the night time temperature will be maintained, while the tap water temperature will be set at a minimum of 20°C. If you are away for an extended period then to save energy adjust the night time temperature to 10°C. After the number of days has expired, the unit will start operating according to the clock programme set. Remember when you return to re-adjust the night time temperature to it’s original setting. Having completed the setting, press the "MENU" button to confirm the new value. 38.10 Installer

This function is for the service engineer only and is code protected.

Save gas Save money Only boilers from eco hometec are fitted with Variable Controlled Output eco hometec Unit 11E Carcroft Enterprise Park Carcroft Doncaster DN6 8DD Tel. 01302 722266 Fax. 01302 728634

Page 60 eco hometec (uk) ltd.