Introduction OPTO-LEAP is designed to ensure the end-to-end optical path availability for the optical fiber network, under power supply failure condition. This is achieved via its intelligent optical switch by sensing, availability of incoming DC supply, providing optical signal by-pass switching under power supply failure condition. In normal operation, the switch is transparently incorporated in the system by use of optical patch cords. In the event of power failure the OPTO-LEAP automatically patches the signals through on end-end basis. By deploying the OPTO- LEAP in mission critical applications the end-end communication is always available. The unit restores the local station communication automatically after the input DC supply is re-established. The optical path through this unit is purely optical; i.e. there is no optical to electrical or electrical to optical conversion. There is no electrical loss or electrical bandwidth limit on the fiber optic path. In event of loss of power, the unit has a failsafe mode that returns the switch in to bypass mode. Application OPTO-LEAP provides high degree of protection for Optical data transmission under power failure condition. OPTO-LEAP can freely be used with any optical product in 1310nm/1550nm window. Common application for this unit is optical system by-pass for optical link restoration under power failure Condition. Features Technology Independent Wideband Operation Unmatched low cost Compact construction Very Low insertion loss Fast switching speed Low power consumption Easy Installation Applications Protection switching Network restoration OPTO-EAP NORMAL STATE OPTO-EAP BY PASS STATE x IN OUT NODE TX NODE RX NODE RX NODE TX

Value added products - Opto_Leap_brochure

Embed Size (px)

DESCRIPTION

Value added products - Opto_Leap_brochure

Citation preview

Introduction OPTO-LEAP is designed to ensure the end-to-end optical path availability for the optical fiber network, under power supply failure condition. This is achieved via its intelligent optical switch by sensing, availability of incoming DC supply, providing optical signal by-pass switching under power supply failure condition. In normal operation, the switch is transparently incorporated in the system by use of optical patch cords. In the event of power failure the OPTO-LEAP automatically patches the signals through on end-end basis. By deploying the OPTO-LEAP in mission critical applications the end-end communication is always available. The unit restores the local station communication automatically after the input DC supply is re-established. The optical path through this unit is purely optical; i.e. there is no optical to electrical or electrical to optical conversion. There is no electrical loss or electrical bandwidth limit on the fiber optic path. In event of loss of power, the unit has a failsafe mode that returns the switch in to bypass mode.

Application

OPTO-LEAP provides high degree of protection for Optical data transmission under power failure condition. OPTO-LEAP can freely be used with any optical product in 1310nm/1550nm window. Common application for this unit is optical system by-pass for optical link restoration under power failure Condition.

Features

Technology Independent

Wideband Operation

Unmatched low cost

Compact construction

Very Low insertion loss

Fast switching speed

Low power consumption

Easy Installation

Applications

Protection switching

Network restoration

OPTO-EAP

NORMAL STATE

OPTO-EAP

BY PASS STATE

xIN OUT

NODE TX

NODE RX

NODE RX

NODE TX

Parameter Min Typical Max. Units

Operating Wavelength Range (λOp)

1260~1360 and/or 1510~1610 nm

Insertion loss 1.3 dB

Polarization dependent loss

0.1 dB

Return loss

45 dB

Channel cross talk

60 dB

Switching time

10 ms

Operating current

200 mA

Operating voltage (1)

-40 -48 -60 VDC

Durability

106 cycles

Optical Power Handling

500 mW

Operating temperature

0 50 °C

Storage temperature

-40 85 °C

(1) Can be configured for – 20VDC.

The OPTO-LEAP unit will go in a Bypass state under any of the following conditions: !"If there is a loss of electrical power !"Manual By-Pass if the front panel mode switch is put in to Bypass

mode. (Unit is switched off)

Technical Specifications

Email: [email protected]

Commtel Networks Pvt. Ltd.,23, White Castle, 34-35 Union Park, Chembur, Mumbai - 400 071, Tel. (022)-4272 0001