www.joslynclark.com2
International Ratings For World Wide Applications UL Listed CSA certified 600V/660V/1000V/1500V
Joslyn Clark’s unique Compact AC Vacuum Contactors & Starters are ideal for tough industrial applications. The compact design pro-vides flexibility for retrofitting to all existing air break contactors, thus enabling an existing application to continue with maintenance cost and down time eliminated.
applications and for use with all types of motors including high efficiency IEC motors & NEMA design E motors.
USAVAC® COMPACT INTERNATIONAL AC VACUUM CONTACTOR
Nema Size 4 IEC 200A
JOSLYN CLARK VACUUM CONTACTOR FEATURES
VACUUM INTERRUPTER ADVANTAGES
800.390.64053
ENGINEERING DATATechnical Specifications CV Series Power Rating
Motor HP/KW AC3
Voltage 135A 200A
--------
----
------------
Three Phase Transformer Load KVAVoltage 150A 200A
Three Phase Capacitor Load KVARVoltage 150A 200A
DescriptionCat #s s s
Standard
Power Ratings Enclosed
Insul. & Operating VoltRated Oper. AC1Rated Oper. AC3Rated Oper. AC4Rated FrequencyMaking CurrentBreaking Current
Dielectric StrengthInterupting CurrentShort Time Current 1 Sec.Short Time Current 10 SecMechanical LifeElect. Life AC3 DutySwitching FrequencyWithstand CurrentChop Current MaxOperating RangeInrush Power VAHolding Power VAOpening Time MSClosing Time MSPick-Up VoltageDrop-Out VoltageRecommended CPT
Applications RatingsMounting InstallationAltitudeAmbient Storage o o o o
Operating o o o o
Vibration / ShockWeight
Options
Auxilliary Contact Kits
Only 1 Kit can be added for total of 3 N/O 3 N/C contacts (1 N/O 1N/C is standard).
Coils
Description Hz. Cat.Suffix
3.588.9
3.383.8
7.5190.5
4X .389.5
.9022.9
1.025.4
.4110.4
*6.44163.6
5.3134.6
6.25158.7
1.025.4
1.6942.8 TYP.
.9724.5
4X .307.6
8.32211.3
.348.6
.6817.3
* 5.97151.6
3.588.9
MTG.PLATE
.9022.9
7.5190.5
MTG. PLATE
3.383.8
MTG. PLATE
1.025.4
.4110.4
* WIDTH DIMENSION FOR CV DC COIL DESIGNS
OPTIONAL AUX.CONTACT KIT
6X 3/8-16 UNF-2B
8.66220.0
5.93150.6
4.34110.2
4.36110.8
NOTE:
MOUNTING PLATEHOLE PATTERN
NOT TO SCALE
SCHEMATIC
SEPARATEAC SOURCE
STOP
START
AC CONTROL
WIRING DIAGRAM
M
(13) (14)
(A1) (A2)
(43)
(44)
(51)
(52)
(63)
(64)
(71)
(72)
L1 L2 L3
T1 T2 T3
OPT
ION
AL
(AK
1 O
R A
K3) (14)
(21)
(22)
SEPARATEDC SOURCE
(34)
(A2)
(33)
START
(A1)
STOP
M
125VDC CONTROL
M
(44)
T1
(13)
T3
(43)
(21)
(52)
(64)
(72)
(63)
(22)
(14)
(51)
OPT
ION
AL
(AK
1 O
R A
K3)
T2
(71)
(33)
(34)
LATE BREAK
M
FOR 250 DC CONTACT 21/22 ISLATE BREAK N/C IN SERIES WITH 'M' LATE BREAK
(A2)
(A1)
L1 L2 L3
M
(A1)
(A2)
(13)
LATE BREAK
M
www.joslynclark.com4
JOSLYN CLARK VACUUM CONTACTOR FEATURES
VACUUM INTERRUPTER ADVANTAGES
Nema Size 5 IEC 400A
International Ratings For World Wide Applications UL Listed CSA certified 600V/660V/1000V/1500VJoslyn Clark’s unique Compact AC Vacuum Contactors & Start-ers are ideal for tough industrial applications. The compact design provides flexibility for retrofitting to all existing air break contactors, thus enabling an existing application to continue with maintenance cost and down time eliminated.
applications and for use with all types of motors including high efficiency IEC motors & NEMA design E motors.
USAVAC® COMPACT INTERNATIONAL AC VACUUM CONTACTOR
800.390.64055
CV Series Technical Specifications
ENGINEERING DATAPower Rating
Motor HP/KW AC3Voltage 270A 400A
----
------------
Three Phase Transformer Load KVAVoltage 270A 400A
Three Phase Capacitor Load KVARVoltage 270A 400A
Options
Only 1 Kit can be added for total of 3 N/O 3 N/C contacts
CoilsDescription Hz. Cat.Suffix
DescriptionCat #Standard
Power Ratings EnclosedInsul. & Operating Volt
Rated Oper. AC1
Rated Oper. AC3
Rated Oper. AC4
Rated Frequency
Making Current
Breaking Current
Dielectric Strength
Interupting Current
Short Time Current 1 Sec.
Short Time Current 10 Sec
Mechanical Life
Elect. Life AC3 Duty
Switching Frequency
Withstand Current
Chop Current Max
Operating Range
Inrush Power VA
Holding Power VA
Opening Time MS
Closing Time MS
Pick-Up Voltage
Drop-Out Voltage
Recommended CPT
Applications Ratings
Mounting Installation
Altitude
Ambient Storage o o o o
Operating o o o o
Vibration / ShockWeight
6.83173.5
.389.7
.5915.0
8.25209.6
2X .389.7
2X .7519.1
4X .389.5
8.0203.2
6X .410.2
9.1231.1
2.5464.6
TYP.
7.75196.7
.7117.9
6.83173.5
MTG. PLATE
8.25209.6
MTG. PLATE
1.4637.0
.389.7
.5914.9
4X .389.5
MTG. PLATE
* 8.59218.2
.615.2
OPTIONAL AUX.CONTACT KIT
2X 4.76120.8
6.46164.0
9.0228.6
9.16
232.6MTG. PLATE
9.25235.0
OVERALL
DEPTH OF CONTACTOR 6.46" (164mm)
* WIDTH DIMENSION FOR CV DC COIL DESIGNS & ALL CVC COIL DESIGNS. NOTE:
1. ALL DIMENSIONS IN INCHES [mm]
MOUNTING PLATEHOLE PATTERN
NOT TO SCALE
(A1)
(A2)M
LATE BREAK
(34)
(33)
(71)
OPT
ION
AL
(AK1
OR
AK3
) (51)
(14)
(22)
(63)
(72)
(64)
(52)
(21)
(43) (13)
(44)
M
M
STOP
(A1)
START
(33)
(A2)
(34)
SEPARATEDC SOURCE
(22)
(21)
(14)
OPT
ION
AL
(AK1
OR
AK3
)
L1 L3
T1
L2L1
(72)
(71)
(64)
(63)
(52)
(51)
(44)
(43)
(A2)(A1)
(14)(13)
M
WIRING DIAGRAM
AC CONTROL
START
STOP
SEPARATEAC SOURCE
SCHEMATIC
T1 T3
L2
T2
T3T2
L3
125VDC CONTROL
FOR 250V DC CONTACT 21/22 ISLATE BREAK N/C IN SERIES WITH 'M' LATE BREAK
LATE BREAK
M
(A1)
(A2)
(13)
M
www.joslynclark.com6
Nema Size 6 IEC 600A
International Ratings For World Wide Applications UL Listed CSA certified 600V/660V/1000V/1500VJoslyn Clark’s unique Compact AC Vacuum Contactors & Starters are ideal for tough industrial applications. The com-pact design provides flexibility for retrofitting to all existing air break contactors, thus enabling an existing application to continue with maintenance cost and down time eliminated.
applications and for use with all types of motors including high efficiency IEC motors & NEMA design E motors.
USAVAC® COMPACT INTERNATIONAL AC VACUUM CONTACTOR
JOSLYN CLARK VACUUM CONTACTOR FEATURES
VACUUM INTERUPTER ADVANTAGES
800.390.64057
Power RatingTechnical Specifications CV Series
ENGINEERING DATA
DescriptionCat #Standard
Power Ratings Enclosed
Insul. & Operating Volt
Rated Oper. AC1
Rated Oper. AC3
Rated Oper. AC4
Rated Frequency
Making Current
Breaking Current
Dielectric Strength
Interupting Current
Short Time Current 1 Sec.
Short Time Current 10 Sec
Mechanical Life
Elect. Life AC3 Duty
Switching Frequency
Withstand Current
Chop Current Max
Operating Range
Inrush Power VA
Holding Power VA
Opening Time MS
Closing Time MS
Pick-Up Voltage
Drop-Out Voltage
Recommended CPT
Applications Ratings
Mounting Installation
Altitude
Ambient Storage o o o o
Operating o o o o
Vibration / ShockWeight
Motor HP/KW AC3Voltage 540A 600A
----
------------
Three Phase Transformer Load KVAVoltage 540A 600A
Three Phase Capacitor Load KVARVoltage 540A 600A
Options
Only 1 Kit can be added for total of 3 N/O 3 N/C contacts (1 N/O 1 N/C Standard)
CoilsCat.Suffix
6.83173.5
.6015.2
.389.5
8.25209.6
2X .389.5
4X .389.5
MTG. HOLES
2X .7519.1
8.0203.2
9.1231.1
10.36263.1
2.5464.6
TYP.6X .389.6 .84
21.4
1.4536.8
1.6441.6
.615.2
* 8.59218.2
.389.7
4X .389.5
MTG. PLATE .59
14.9
6.83173.5
MTG. PLATE
8.25209.6
MTG. PLATE
2X .7519.1
OPTIONAL AUX.CONTACT KIT
* WIDTH DIMENSION FOR CV DC COIL DESIGNS & ALL CVC COIL DESIGNS.
6.46164.0
1.2531.8
2X 2.8973.4
9.16232.6
MTG PLATE 9.0
228.6
12.05305.9
OVERALL
9.25235.0
DEPTH ON CONTACTOR 6.46" (164mm)
NOTE: 1. ALL DIMENSIONS IN INCHES [mm]
MOUNTING PLATEHOLE PATTERN
NOT TO SCALE
L3
T2 T3
T2
L2
T3T1
SCHEMATIC
SEPARATEAC SOURCE
STOP
START
M
(13) (14)
(A1) (A2)
(43)
(44)
(51)
(52)
(63)
(64)
(71)
(72)
L1 L2
T1
L3L1
OPT
ION
AL
(AK1
OR
AK3
)
(14)
(21)
(22)
SEPARATEDC SOURCE
(34)
(A2)
(33)
START
(A1)
STOP
M
M
(44)
(13)(43)
(21)
(52)
(64)
(72)
(63)
(22)
(14)
(51)
OPT
ION
AL
(AK1
OR
AK3
)
(71)
(33)
(34)
LATE BREAK
M (A2)
(A1)
WIRING DIAGRAM
AC CONTROL
LATE BREAK
M
(A1)
(A2)
(13)
M
www.joslynclark.com8
Joslyn Clark, the Motor Control Specialists,
vacuum Contactors for heavy industrial applica-
Vacuum Contactors enclose the power contacts within a vacuum chamber. This sophisticated technology results in the following advantages.
analytical testing. Specially selected materials are used such as high alumina ceramics for high temperature processing and degassing. Contact materials are selected for transient voltage generation control.
interrupters are tested mechanically and electrically to ensure vacuum integrity. All interrupters are held for a period of time and retested before being installed in contactors and shipped to the customer.
USAVAC® VACUUM INTERRUPTERS AND CONTACTORS
800.390.64059
MEDIUM VOLTAGE CONTACTORSLOW VOLTAGE CONTACTORS
auxiliary switches
LOW & MEDIUM VOLTAGE CONTACTOR REPLACEMENT PARTS
The modular design of Joslyn Clark Vacuum Contactors facilitates quick and easy maintenance in order to reduce
machine down time.
www.joslynclark.com10
reduced voltage applications.
and starters incorporate many useful features to insure ease of maintenance, versatility, and reliability. A three phase contactor contains ten basic parts. The contactor can be assembled or dismantled without the use of any tools.
The control module contains the coil and auxiliary contacts wired to a terminal block and is easily removed for checking or immediate replacement. The phase assembly and the control module are the only two replacement parts. The phase assem-bly is a vacuum interrupter containing the power switching contacts.
LOW VOLTAGE FEATURES
800.390.640511
ampere.
Power Application Ratings
Technical Specifications
Accessories & Options:
available.
non-combination forms are available
Vacuum Contactor & Starter Ratings 200V-3600V
ENGINEERING DATA
Motor HPVolts 160A 320A 600A 1000A
-----------------------------
Transformer Load KVAVolts 160A 320A 600A 1000A
Capacitor Load KVARVolts 160A 320A 600A 1000A
160A 320A 600A 1000ACat No. 3 Pole 1.5KV 3.6KVPower RatingsRated Insulating andOperational VoltagetRated Operational CurrentRated FrequencyMaking CurrentBreaking Current
Dielectric Strength/BIL.
Interrupting Current
Withstand CurrentShort Time Current 1 Sec.
2 Sec.Mechanical LifeElectrical Life at RatedCurrent - AC3 DutySwitching FrequencyChop Current MaxControl RatingsDescriptionRated Control Voltage
Allowable Fluctuation
Closing Power VA/DurationHolding PowerOpening Time Ave.Closing Time Ave.Pick-Up VoltageDrop-Out VoltageRecommendedControl TransformerApplications RatingssInstallationAltitude without Derating
Ambient Storage Operating
Vibration/ShockWeight 160/320ADimensions
8.1206.2
2.5665.0
3.076.2
4.5114.3
5.28134.0
6.5165.1
.8120.6
.389.5
4X .389.7
8.88
225.4
3.076.2
TYP.
3X .4411.1
3X .5614.3
4.14105.3
.5112.8
1.1228.4TYP.
8.12206.2
MTG.PLATE
1.4436.5
3.076.2
MTG. PLATE
4.5114.3
MTG. PLATE
2.5665.0
MTG. PLATE
.389.7
MTG. PLATE
4X .389.7
MTG. PLATE
.8120.6
6.5165.1
MTG. PLATE
6.39162.4
5.28134.0
7.91200.8
3.3885.8
7.49190.1
MTG. PLATEHOLE PATTERN
NOTE:
1. ALL DIMENSIONS IN INCHES [mm]
NOT TO SCALE
www.joslynclark.com12
contactors are ideal for
alternative line terminal position enabling line and load termination to be on same side of contactor. Ideal for dropout starter designs. Can be easily converted.
contactors and starters offer many unique features to create easy maintenance, dependability and versatility.
enclosures. The modular design allows for a simplified
replacement. A factory set half shell phase assembly and replacement control module are the only replacement parts.
The Joslyn Clark family of low and medium voltage vacuum contactors and starters are available in combination and non-combination enclosures. Controllers are available for across the line, reduced voltage, reversing, and non-reversing
USAVAC® MEDIUM VOLTAGE
800.390.640513
Vacuum Contactor & Starter Ratings
ENGINEERING DATA
Power Application Ratings
Technical Specifications
Description
Catalog Number & 2.5KV
Rated Voltage 5.0KV
7,2KV
Power RatingsOperational Rated CurrentOperational Rated Frequency HZE1 Interrupt Rating 2.5KV --------MVA & KA Values 5.0KV --------Contactor Only 7.2KV --------E2 Fuse Coordination Rating --------MVA & KA 5.0KV
Withstand KA 5.0KV --------Short Time Current 1 Sec. KA
5 Sec. KA15 Sec. KA
Switching FrequencyElec. Life at Rated Current
Mechanical LifeDielectric StrengthImpulse withstand B.I.L.
Chopping Current Max.
Control Ratings AC&DCRated Control VoltageAllowable FluctuationClosing Power VA/DurationHolding Power
Opening Time Ave.Closing Time Ave.Pick up Voltage Min.Drop Out Voltage Ave.Recommended Control Trans.Application ConditionsStandard CurrentAuxiliary VoltageContact ACRatings DCAdditional CurrentAuxiliary Contact VoltageRelay Ratings AC
DCWeight
Voltage KVMotor Type Current Motor HP
or Syn Motor
Motor
or Syn Motor
Motor
or Syn Motor
Motor
or Syn MotorTransformer Load KVAThree
Transformer
Capacitor Load KVARThree
Capacitor
10.0254.0
4X .389.5
1.7644.8
.5012.7
9.0228.6
14.5368.3
5.0127.0
TYP.
6.87174.5
3X .5714.4
3X .5915.1
.9123.1
1.7644.8
13.52343.5
MTG. PLATE
10.0254.0
MTG. PLATE
9.0228.6
MTG. PLATE
1.7644.8
MTG. PLATE
.5012.7
MTG. PLATE
4X .389.5
MTG. PLATE
11.53292.8
1.2331.2
10.0254.0
MTG. PLATE
12.68322.1
2X 11.93302.9
5.18131.7
NOTE:
1. ALL DIMENSIONS IN INCHES [mm]
MOUNTING PLATEHOLE PATTERN
NOT TO SCALE
www.joslynclark.com14
UL 347 LISTEDCSA 2-22 APPROVED
arm.
Maintenance free Joslyn Clark Vacuum Contactors.
NOTE:
FULL VOLTAGE NON REVERSING & REVERSING MOTOR STARTERS
Maximum NEMA 12Ampere Rating HP Ratings Catalog No.
2300V VACUUM STARTERS With Fused Load Break Disconnect
Maximum NEMA 12 Ampere Rating HP Ratings Catalog No.
4160V VACUUM STARTERS With Fused Load Break Disconnect
Maximum NEMA 12 Ampere Rating HP Ratings Catalog No.
6600V VACUUM STARTERS With Fused Load Break Disconnect
800.390.640515
-
automatic grounding arm.
Compartments.
Maintenance free Joslyn Clark Vacuum Contactors.
Suitably rated current limiting power fuses with striker pins and
secondary.
MEDIUM VOLTAGE FEEDER SECTION
KVA KVAR Ampere Rating Ratings Rating Catalog No.
2300V VACUUM STARTERS With Fused Load Break Disconnect
KVA KVAR Ampere Rating Ratings Rating Catalog No. 4160V VACUUM STARTERS With Fused Load Break Disconnect
KVA KVAR Ampere Rating Ratings Rating Catalog No. 7200V VACUUM STARTERS With Fused Load Break Disconnect
www.joslynclark.com16
Voltage Auto Transformer Starters incorporate equipment exactly as the full voltage starters, with the additional following equipment
Incomplete Sequence Timer
REDUCED VOLTAGE AUTO TRANSFORMERS
NON REVERSING CLOSED TRANSITIONUL 347 LISTED
CSA 2-22 APPROVED
Max HP Cat # NEMA 12 Max HP Cat # NEMA 12
4160V RVAT Starters With Fused Motor Load Break Disconnect
6600V RVAT Starter With Fused Motor Load Break Disconnect
NOTE:
800.390.640517
DescriptionEnclosed TypeNEMA 1, 3R, 12
Change Cat. No.Character Indicated To: Typical Catalog Number
Cover ControlsPush Button & Selector Switches
Hand-Off-Auto Selector Switch B
Start-Stop Push Buttons C
2 or 3 Position Selector Switch B
Forward-Reverse-Stop Push Buttons C
Pilot Lights
With Electrical Interlock:
Standard Transformer Type, Red Lens 13
Push-to-Test Transformer Type, Red Lens 14
Modication 13-14. Lens color. Example: Order
(13+15) = Std. Transformer with interlock & color lens Green,
Green N/C
Example Blue N/C
Pilot Light Red Lens -13 White N/C
Pilot Light Green Lens -(13 + 15) Yellow N/C
Amber N/C
Clear N/C
Auxiliary RelaysExtra 2 N. O. & 2 N. C. Aux. Contacts 21
Time Relay ON Delay 22
Time Relay OFF Delay 23
Time Relay ON Delay & Instantaneous 24
Time Relay OFF Delay & Instantaneous 25
Time Relay ON Delay & OFF Delay 23
Overload Relays
7777 Electronic Motor Management Relay 27
27A
Option 27
31A
31B
30
29
62
Includes C/TS & P/T’s
Lightning Surge Protector 41
Overhead Bus 800A/Cubicle (24” Length) 47
Overhead Bus 1200A/Cubicle (24” Length) 48
Overhead Bus 1600A/Cubicle (24” Length) 49
* A ground Bus is included in busbar prices.
Overhead Bus 800A/Cubicle (36” Length) 30 or 36 50
Overhead Bus 1200A/Cubicle (36” Length) 30 or 36 51
Overhead Bus 1600A/Cubicle (36” Length) 30 or 36 52
Incoming & Auxilliary Cubicle Options18” Cable Pull Section 54
24” Cable Pull Section (use with option #29) 55
400A Incoming Section Unit Unfused 56
400A Incoming Section Unit Fused 57
600A Incoming Section Unit Unfused 58
600A Incoming Section Unit Fused 59
1200A Incoming Section Unit Unfused 601200A Incoming Section Unit Fused 61
Modifications For Combination USAVAC Medium Voltage Controllers
CONTROLLER MODIFICATIONS
www.joslynclark.com18
USAVAC MEDIUM VOLTAGE CONTROLLERSSpecification for Medium Voltage Full Voltage Starters5KV 400 AMP 3000HPThe Joslyn Clark line of medium vacuum starters incorporate the Joslyn
provide for a compact design that has unique feature and safety benefits providing a simple, safe maintenance-free starter. Technical details of the vacuum contactor are provided in the Joslyn Clark Control Catalog.-In detail the starter comprises of:
automatic grounding arm. The switch is provided with a viewing window mounted in the fixed mounted panel allowing for a visible check that the switch has been opened and the blades grounded. The disconnect switch is interlocked with the front medium voltage access door to ensure access to the medium voltage compartment can only be achieved when the switch has been opened and the blades grounded.
Isolation between the load break disconnect switch compartment, the medium voltage compartment and grounded metal isolation between the low voltage and medium voltage compartments.
preventing the risk of single phasing in the event of one single fuse blowing.
bimetal ambient compensated overload relay mounted in the low voltage compartment, heater elements are fitted. The relay is manually reset via low voltage compartment.
The low voltage fuse will be mounted in the low voltage compartment. The two high voltage primary fuses will be mounted in the medium voltage compartment.
The above starters can be provided and are suitable for reversing applications whereby this specification remains
normally closed auxiliary contacts. The contactor will be provided with an additional mechanical interlock that will be mechanically and electrically interlocked with the forward contactor.
800.390.640519
USAVAC MEDIUM VOLTAGE AUTO TRANSFORMER CONTROLLERSSPECIFICATION FOR JOSLYN CLARK MEDIUM VOLTAGE, REDUCED VOLTAGE, AUTO TRANSFORMER STARTERS
These starters are designed for automatic starting of squirrel cage motors when starting current or torque must be reduced.
Joslyn Clark reduced voltage auto transformer starters incorporate equipment exactly as the across-the-line starters detailed above with the
vacuum contactor.
dimensions for the reduced voltage auto transformer starter would
would be interlocked to the main disconnect switch, thus insuring in addition to the normal interlock described above that the right hand medium voltage compartment door cannot be opened until the disconnect switch is in the off position, and grounded thus releasing an interlock which will then allow access to the right hand cubicle to insure access to that compartment only when the incoming power supply has been isolated and grounded.
These starters are also available in the reversing arrangement for reversing applications. The specification will be exactly as above for that medium voltage reduced voltage auto-transformers starters with the addition of two medium voltage contactors with two normally opened, two normally closed auxiliary contacts and mechanical interlock on the forward and reverse contactors.
plated bus system is connected at shipping, splits by a splice bus. Shipping splits are provided every two or three
2100 West Broad StreetElizabethtown, NC 28337-8826
800.476.6952
DAN 123010a - JC VCB