UTStarcom TN780Hardware Description Guide

Release 1.2Revision B

Product Order No. TN780-HWG-1.2-B

UTStarcom Inc.www.utstarcom.com

Page 2: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page ii

Copyright© 2004 UTStarcom Inc. All rights reserved.

This Manual is the property of UTStarcom Inc. and is confidential. No part of this Manual may be reproduced for any purposes or transmitted in any form to any third party without the express written consent of UTStarcom.

UTStarcom makes no warranties or representations, expressed or implied, of any kind relative to the information or any portion thereof contained in this Manual or its adaptation or use, and assumes no responsibility or liability of any kind, including, but not limited to, indirect, special, consequential or incidental damages, (1) for any errors or inaccuracies contained in the information or (2) arising from the adaptation or use of the information or any portion thereof including any application of software referenced or utilized in the Manual. The information in this Manual is subject to change without notice.

TrademarksUTStarcom® is a trademark of UTStarcom Inc.

GoAhead is a trademark of GoAhead Software, Inc.

All other trademarks in this Manual are the property of their respective owners.

UTStarcom TN780 and UTStarcom Optical Line Amplifier Regulatory ComplianceFCC Class A

This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Modifying the equipment without UTStarcom's written authorization may result in the equipment no longer complying with FCC requirements for Class A digital devices. In that event, your right to use the equipment may be limited by FCC regulations, and you may be required to correct any interference to radio or television communications at your own expense.

DOC Class A

This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus as set out in the interference-causing equipment standard titled “Digital Apparatus," ICES-003 of the Department of Communications.

Cet appareil numérique respecte les limites de bruits radioélectriques applicables aux appareils numériques de Classe A prescrites dans la norme sur le matériel brouilleur: "Appareils Numériques," NMB-003 édictée par le Ministère des Communications.

Warning

This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.

FDA

This product complies with the DHHS Rules 21 CFR Subchapter J, Section 1040.10, Applicable at date of manufacture.

TN780 Hardware DescriptionUTStarcom Inc. Release 1.2

Page 3: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page iContents

Contents

About this DocumentObjective . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiii

Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiii

Document Organization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiv

Related Documents. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiv

Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xv

Technical Assistance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xv

Chapter 1 - IntroductionUTStarcom TN780. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2UTStarcom Optical Line Amplifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2UTStarcom Dispersion Management Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2

Chapter 2 - UTStarcom TN780DTC Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3

Front View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3

DTC Compliancy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6

DTC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7Functional Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8Rack Mounting Ears . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-9Power Entry Module (PEM). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-10

External Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-10Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-10Technical Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-11Power Distribution Architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-11

I/O Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-12External Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-13Bay-Level Alarm LEDs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-13Chassis-Level Alarm LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-13Chassis-Level Audio Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-14Alarm Cutoff Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-14Lamp Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-14Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-15

Timing and Alarm Panel (TAP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-15

TN780 Hardware Description Release 1.2UTStarcom Incorporated

Page 4: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page ii Contents

External Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-16Technical Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-16Alarm Input Contact Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-17Alarm Output Contact Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-18

Fan Tray . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-22Technical Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-23

Air Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-23Technical Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-24

Card Cage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-24

Management Control Module (MCM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-25MCM-A Functional Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-25MCM-B Functional Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-26Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-27External Indicators and Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-27

Circuit Pack Level LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-29Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-29Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-30

Band Mux Module (BMM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-31BMM-4-CX-XX-A Functional Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-31BMM-4-CX-XX-B Functional Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-32BMM-8 Functional Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-33Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-35External Indicators and Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-36

Circuit Pack Level LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-37Port Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-37

Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-37

Digital Line Module (DLM). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-42Functional Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-42Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-43External Indicators and Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-44

Circuit Pack Level LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-45Port Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-45

Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-45Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-46

Tributary Adapter Module 10G (TAM-2-10G) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-47Functional Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-47Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-48External Indicators and Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-48

Circuit Pack Level LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-49TOM-10G LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-49

Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-49

Tributary Adapter Module 2.5G (TAM-4-2.5G) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-51Functional Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-51

UTStarcom IncorporatedTN780 Hardware Description Release 1.2

Page 5: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page iiiContents

Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-52External Indicators and Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-52

Circuit Pack Level LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-53TOM-2.5G LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-53

Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-53

Tributary Adapter Module 1G (TAM-4-1G) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-55Functional Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-55Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-56External Indicators and Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-56

Circuit Pack Level LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-56TOM-1G-LX LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-57

Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-57

Tributary Optical Module 10G-SR1 (TOM-10G-SR1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-58Functional Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-58Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-58Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-59

Optical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-59Interface Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-60

Tributary Optical Module 10G-IR2 (TOM-10G-IR2). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-61Functional Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-61Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-61Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-62

Optical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-62Interface Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-63

Tributary Optical Module 2.5G-SR1 (TOM-2.5G-SR1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-64Functional Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-64Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-64Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-65

Optical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-65Interface Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-66

Tributary Optical Module 2.5G-IR1 (TOM-2.5G-IR1). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-67Functional Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-67Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-67Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-68

Optical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-68Interface Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-69

Tributary Optical Module 1G-LX (TOM-1G-LX) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-70Functional Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-70Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-70Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-71

Optical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-71Interface Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-72

Blank Circuit Packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-73

TN780 Hardware Description Release 1.2UTStarcom Incorporated

Page 6: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page iv Contents

Chapter 3 - UTStarcom Optical Line AmplifierOTC Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2

Front View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2

OTC Compliancy. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3

OTC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4Functional Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5Rack Mounting Ears . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-6Power Entry Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-6

External Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-7Technical Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-8Power Distribution Architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-8

I/O / Alarm Panel (IAP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-9External Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-10Alarm Cutoff Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-11Lamp Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-11Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-11Technical Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-12Alarm Input Contact Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-12Alarm Output Contact Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-14

Fan Tray . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-17Fan Tray LEDs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-18Technical Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-18

Air Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-18Technical Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-19

Card Cage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-19

Optical Management Module (OMM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-20Functional Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-20Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-21External Indicators and Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-21

Circuit Pack Level LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-22Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-22Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-23

Optical Amplifier Module (OAM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-24OAM-CX-A Functional Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-24OAM-CX-B Functional Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-25Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-26External Indicators and Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-27

Circuit Pack Level LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-27Port Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-28

Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-28Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-29

Blank Circuit Packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-30

UTStarcom IncorporatedTN780 Hardware Description Release 1.2

Page 7: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page vContents

Chapter 4 - UTStarcom Dispersion Management ChassisDMC Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2

DMC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3Functional Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3

Dispersion Compensation Module (DCM). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5Functional Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-7Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-8

TN780 Hardware Description Release 1.2UTStarcom Incorporated

Page 8: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page vi Contents

UTStarcom IncorporatedTN780 Hardware Description Release 1.2

Page 9: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page viiFigures

Figures

Figure 1-1 Digital Optical Network. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2Figure 2-1 DTC front view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-4Figure 2-2 Two DTCs in a rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-5Figure 2-3 DTC dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-9Figure 2-4 PEM faceplate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-10Figure 2-5 Power distribution diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-12Figure 2-6 I/O panel front view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-13Figure 2-7 TAP front view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-16Figure 2-8 MCM functional block diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-27Figure 2-9 MCM faceplate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-28Figure 2-10 BMM control plane block diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-35Figure 2-11 BMM-4 data plane block diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-35Figure 2-12 BMM-4 faceplate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-36Figure 2-13 DLM functional block diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-43Figure 2-14 DLM faceplate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-44Figure 2-15 TAM-2-10G functional block diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-48Figure 2-16 TAM-2-10G faceplate. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-48Figure 2-17 TAM-4-2.5G functional block diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-52Figure 2-18 TAM-4-2.5G faceplate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-52Figure 2-19 TAM-4-1G functional block diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-56Figure 3-1 OTC front view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-2Figure 3-2 OTC dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-6Figure 3-3 PEM faceplate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-7Figure 3-4 Power distribution diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-9Figure 3-5 OTC I/O / Alarm panel front view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-10Figure 3-6 OMM functional block diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-21Figure 3-7 OMM faceplate. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-22Figure 3-8 OAM control plane block diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-26Figure 3-9 OAM data plane diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-26Figure 3-10 OAM faceplate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-27Figure 4-1 Dispersion Management Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-2Figure 4-2 Dispersion Compensation Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-7

TN780 Hardware Description Release 1.2UTStarcom Incorporated

Page 10: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page viii Figures

UTStarcom IncorporatedTN780 Hardware Description Release 1.2

Page 11: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page ixTables

Tables

Table 2-1 List of DTC hardware equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3Table 2-2 DTC hardware compliancy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6Table 2-3 DTC product details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7Table 2-4 DTC technical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8Table 2-5 Visual alarm indicators on the PEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-10Table 2-6 PEM technical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-11Table 2-7 Visual alarm indicators - bay level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-13Table 2-8 Visual alarm indicators - chassis level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-14Table 2-9 Audio alarm indicators - chassis level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-14Table 2-10 I/O panel connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-15Table 2-11 TAP connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-16Table 2-12 Alarm relay contact specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-16Table 2-13 Alarm input contact pin assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-17Table 2-14 Alarm output contact pin assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-18Table 2-15 Visual alarm indicators on the fan tray . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-22Table 2-16 Fan tray technical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-23Table 2-17 Air filter technical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-24Table 2-18 DTC circuit pack assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-24Table 2-19 MCM product details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-25Table 2-20 MCM-A and MCM-B differences . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-25Table 2-21 MCM status LED indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-29Table 2-22 MCM connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-29Table 2-23 MCM technical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-30Table 2-24 BMM product details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-31Table 2-25 BMM status LED indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-37Table 2-26 Port visual alarm indicators on BMM circuit pack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-37Table 2-27 BMM-4 connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-37Table 2-28 BMM-8 Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-39Table 2-29 BMM technical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-40Table 2-30 BMM-4 optical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-40Table 2-31 BMM-8 Optical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-41Table 2-32 DLM product details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-42Table 2-33 DLM status LED indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-45Table 2-34 Port visual alarm indicators on DLM circuit pack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-45Table 2-35 DLM connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-45Table 2-36 DLM technical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-46Table 2-37 DLM optical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-46Table 2-38 TAM-2-10G product details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-47Table 2-39 TAM-2-10G status LED indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-49

TN780 Hardware Description Release 1.2UTStarcom Incorporated

Page 12: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page x Tables

Table 2-40 TOM-10G status indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-49Table 2-41 TAM-2-10G technical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-49Table 2-42 TAM-2-10G tributary interface specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-50Table 2-43 TAM-4-2.5G product details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-51Table 2-44 TAM-4-2.5G status LED indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-53Table 2-45 TOM-2.5G status indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-53Table 2-46 TAM-4-2.5G technical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-53Table 2-47 TAM-4-2.5G tributary interface specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-54Table 2-48 TAM-4-1G product details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-55Table 2-49 TAM-4-1G status LED indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-56Table 2-50 TOM-1G-LX status indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-57Table 2-51 TAM-4-1G technical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-57Table 2-52 TAM-4-1G tributary interface specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-57Table 2-53 TOM-10G-SR1 product details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-58Table 2-54 TOM-10G-SR1 connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-58Table 2-55 TOM-10G-SR1 technical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-59Table 2-56 TOM-10G-SR1 tributary port IN optical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-59Table 2-57 TOM-10G-SR1 tributary port OUT optical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-60Table 2-58 TOM-10G-SR1 tributary facilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-60Table 2-59 TOM-10G-IR2 product details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-61Table 2-60 TOM-10G-IR2 connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-61Table 2-61 TOM-10G-IR2 technical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-62Table 2-62 TOM-10G-IR2 tributary port IN optical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-62Table 2-63 TOM-10G-IR2 tributary port OUT optical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-63Table 2-64 TOM-10G-IR2 tributary facilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-63Table 2-65 TOM-2.5G-SR1 product details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-64Table 2-66 TOM-2.5G-SR1 connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-64Table 2-67 TOM-2.5G-SR1 technical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-65Table 2-68 TOM-2.5G-SR1 tributary port IN optical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-65Table 2-69 TOM-2.5G-SR1 tributary port OUT optical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-66Table 2-70 TOM-2.5G-SR1 tributary facilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-66Table 2-71 TOM-2.5G-IR1 product details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-67Table 2-72 TOM-2.5G-IR1 connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-67Table 2-73 TOM-2.5G-IR1 technical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-68Table 2-74 TOM-2.5G-IR1 tributary port IN optical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-68Table 2-75 TOM-2.5G-IR1 tributary port OUT optical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-69Table 2-76 TOM-2.5G-IR1 tributary facilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-69Table 2-77 TOM-1G-LX product details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-70Table 2-78 TOM-1G-LX connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-70Table 2-79 TOM-1G-LX technical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-71Table 2-80 TOM-1G-LX tributary port IN optical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-71Table 2-81 TOM-1G-LX tributary port OUT optical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-72Table 2-82 TOM-1G-LX tributary facilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-72Table 2-83 DTC blank circuit packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-73

UTStarcom IncorporatedTN780 Hardware Description Release 1.2

Page 13: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page xiTables

Table 3-1 List of OTC hardware equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2Table 3-2 OTC hardware compliancy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3Table 3-3 OTC product details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4Table 3-4 OTC technical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5Table 3-5 Visual alarm indicators on power entry module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-7Table 3-6 PEM technical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-8Table 3-7 Visual alarm indicators - chassis level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-10Table 3-8 Audio alarm conditions - chassis level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-11Table 3-9 OTC connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-11Table 3-10 Alarm relay contact specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-12Table 3-11 Alarm input contact pin assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-12Table 3-12 Alarm output contact pin assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-14Table 3-13 Visual alarm indicators on the fan tray . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-18Table 3-14 Fan tray technical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-18Table 3-15 Air filter technical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-19Table 3-16 Circuit pack assignments in a OTC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-19Table 3-17 OMM product details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-20Table 3-18 OMM status LED indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-22Table 3-19 OMM connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-22Table 3-20 OMM technical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-23Table 3-21 OAM product details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-24Table 3-22 OAM status LED indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-27Table 3-23 Port visual alarm indicators on OAM circuit pack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-28Table 3-24 OAM connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-28Table 3-25 OAM technical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-29Table 3-26 OAM optical specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-29Table 3-27 OTC blank circuit packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-30Table 4-1 DMC hardware equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2Table 4-2 DMC product details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3Table 4-3 DMC technical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3Table 4-4 DCM product details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5Table 4-5 DCM technical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-7Table 4-6 DCM connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-8

TN780 Hardware Description Release 1.2UTStarcom Incorporated

Page 14: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page xii Tables

UTStarcom IncorporatedTN780 Hardware Description Release 1.2

Page 15: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

About this Document

This chapter provides an overview of this document. It includes the:

“Objective” on page xiii

“Audience” on page xiii

“Document Organization” on page xiv

“Related Documents” on page xiv

“Conventions” on page xv

“Technical Assistance” on page xv

ObjectiveThis guide provides an introduction and reference to the UTStarcom® TN780 and Optical Line Amplifier network elements, its deployable configurations, and its hardware architecture. This guide also provides the details of the functional description, functional block diagrams, faceplate diagrams with status indicators and connectors, and the technical specification of all the components.

AudienceThe primary audience for this manual includes network planners, network operations personnel, field technicians, and system administrators who are responsible for deploying and administering Digital Optical Network®. This manual assumes that the reader is familiar with the following topics and products:

Basic internetworking terminology and concepts

Dense Wavelength Division Multiplexing (DWDM) technology and concepts

TN780 Hardware Description Release 1.2 Rev BUTStarcom Incorporated

Page 16: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

About this DocumentPage xiv

Document OrganizationThe following table lists the chapters and its description covered in this manual.

Related DocumentsReader can refer to the following documents to further understand the content of this manual.

Chapter Number: Title Description

CHAPTER 1:

“Introduction“

Provides a high level description of TN780 and Optical Line Amplifier network element features and their network configurations.

CHAPTER 2:

“UTStarcom TN780“

Provides details of the TN780 hardware and the functional description of various circuit packs the TN780 houses. It covers the various audi-ble and visual alarms on the faceplates that indicate the status of the circuit packs.

CHAPTER 3:

“UTStarcom Optical Line Ampli-fier“

Provides details of the Optical Line Amplifier hardware and the func-tional description of various circuit packs it houses. It covers the vari-ous audible and visual alarms on the faceplates that indicate the status of the circuit packs.

CHAPTER 4“UTStarcom Dispersion Manage-ment Chassis“

Provides details of the DMC hardware and its technical specifications.

Appendix A“Acronyms“

Provides a list of acronyms and their definitions used in UTStarcom Technical Publications.

Document Name Document Order Number Description

UTStarcom TN780 System Description

TN780-SDG-1.2-A This guide provides an introduction and refer-ence to Digital Optical Networking Systems which includes UTStarcom TN780 (referred to as TN780) and UTStarcom Optical Line Amplifier (referred to as Optical Line Amplifier) used to build the Digital Optical Networks.

UTStarcom TN780 Site Preparation and Hard-ware Installation Guide

TN780-ING-1.2-A Describes the procedures for initial installation of the UTStarcom TN780 and Optical Line Amplifier network elements at any given site. Includes pro-cedures for site preparation and site testing, sys-tem cabling, safety procedures and hand-over to provisioning activities

TN780 Hardware Description Release 1.2 Rev B UTStarcom Incorporated

Page 17: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page xvConventions

ConventionsThe following table list the document conventions used within this manual.

Technical AssistanceCustomer support for UTStarcom products is available 24 hours a day, seven days a week. For information or assistance with any UTStarcom product, please contact an UTStarcom Customer Service and Technical Support resource using any of the methods listed below.

UTStarcom China

Telephone: 86-10-85205588

Fax: 86-10-85205599

UTStarcom USA

Telephone: 1-510-864-8800

Fax: 1-510-864-8802

UTStarcom corporate website: www.utstarcom.com

UTStarcom TN780 Turn-up and Test Guide

TN780-TTG-1.2-A Provides the procedure for turning up and testing the UTStarcom TN780 and Optical Line Amplifier network elements as well as the individual com-ponents.

UTStarcom MPower GNM User Guide

MP-GNUG-1.2-A Describes the UTStarcom MPower GNM inter-face used to manage the UTStarcom TN780 and Optical Line Amplifier network elements. This guide also includes the procedures for the com-monly performed OAM&P functions.

Convention Item Example

italic font Book or manual titles Refer to the UTStarcom TN780 System Description.

Document Name Document Order Number Description

TN780 Hardware Description Release 1.2 Rev BUTStarcom Incorporated

Page 18: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

About this DocumentPage xvi

TN780 Hardware Description Release 1.2 Rev B UTStarcom Incorporated

Page 19: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

CHAPTER 1

Introduction

UTStarcom offers Digital Optical Networking Systems which help carriers build Digital Optical Networks. The UTStarcom TN780 network element, referred to as the TN780, is the first Digital Optical Networking System which provides digital add/drop and bandwidth management capabilities. Additionally, the UTStarcom Optical Line Amplifiers are provided to extend the optical reach between the TN780s.

An Digital Optical Network, as shown in Figure 1-1 on page 1-2, is comprised of TN780s deployed wherever client access is desired, and Optical Line Amplifiers where client access is not anticipated. The links between the TN780s, referred to as Digital Links, isolate analog engineering and impairments within that Digital Link. Customers can progressively deploy the transport network with TN780s at more points of presence, interconnected by Digital Links, when and where capacity is required, without re-engineering the network.

TN780 Hardware Description Release 1.2UTStarcom Inc.

Page 20: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 1-2 IntroductionPage 1-2

Figure 1-1 Digital Optical Network

UTStarcom TN780The TN780 provides digital bandwidth management within a Digital Optical Network. It provides a means for direct access to client data at 10Gbps, and 2.5Gbps wavelength granularity at any site, allowing flexible selection of whether to multiplex, add/ drop, amplify, groom, or wavelength interchange individual channels. The TN780 can be equipped in a variety of network configurations using a common set of circuit packs. The detailed description of TN780 hardware is provided in “UTStarcom TN780” on page 2-1.

UTStarcom Optical Line AmplifierThe Optical Line Amplifier is used to extend the optical reach between TN780s. The Optical Line Amplifier is deployed at locations where customer access is not anticipated. The detailed description of Optical Line Amplifier hardware is provided in “UTStarcom Optical Line Amplifier” on page 3-1.

UTStarcom Dispersion Management ModuleThe Dispersion Management Module consists of a chassis for dispersion compensation, which can be mounted in the Digital Transport Chassis (DTC) or the Optical Transport Chassis (OTC) rack for the purpose of dispersion compensation. This is an optional module. Details are covered in “UTStarcom Dispersion Management Chassis” on page 4-1

Client

Client Client

Client

Digital Links

Client

Client Client

Client

Digital Links

UTStarcom TN780

UTStarcom Optical Line Amplifier

TN780 Hardware Descriptio

n Release 1 UTStarcom Inc..2
Page 21: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

CHAPTER 2

UTStarcom TN780

The UTStarcom TN780, referred to as the TN780, is a digital node deployed in a Digital Optical Network. The TN780 provides digital bandwidth management and client access to the Dense Wavelength Division Multiplexing (DWDM) transport bandwidth. Refer to the UTStarcom TN780 System Description document for a detailed functional description and application of the TN780.

The TN780 consists of one or more Digital Transport Chassis (DTC) and optionally one or more Dispersion Management Chassis (DMC) for dispersion compensation. Refer to “UTStarcom Dispersion Management Chassis” on page 4-1 for more details on DMC.

This chapter provides a hardware description for the DTC, including a functional description of the hardware, block diagram of the internal signal flow (where applicable), and technical specifications. This chapter includes the following sections:

“DTC Overview” on page 2-3

“DTC Compliancy” on page 2-6

“DTC” on page 2-7

“Management Control Module (MCM)” on page 2-25

“Band Mux Module (BMM)” on page 2-31

“Digital Line Module (DLM)” on page 2-42

“Tributary Adapter Module 10G (TAM-2-10G)” on page 2-47

“Tributary Adapter Module 2.5G (TAM-4-2.5G)” on page 2-51

“Tributary Adapter Module 1G (TAM-4-1G)” on page 2-55

“Tributary Optical Module 10G-SR1 (TOM-10G-SR1)” on page 2-58

“Tributary Optical Module 10G-IR2 (TOM-10G-IR2)” on page 2-61

“Tributary Optical Module 2.5G-SR1 (TOM-2.5G-SR1)” on page 2-64

TN780 Hardware Description Release 1.2UTStarcom Inc.

Page 22: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-2 UTStarcom TN780Page 2-2

“Tributary Optical Module 2.5G-IR1 (TOM-2.5G-IR1)” on page 2-67

“Tributary Optical Module 1G-LX (TOM-1G-LX)” on page 2-70

“Blank Circuit Packs” on page 2-73

For TN780 installation procedures, refer to the UTStarcom TN780 Site Preparation and Hardware Installation Guide. For TN780 turn-up and test procedures, refer to the UTStarcom TN780 Turn-up and Test Guide.

Refer to UTStarcom TN780 Maintenance and Troubleshooting Guide for a description of module Light Emitting Diode (LED) status indicators.

UTStarcom Inc.TN780 Hardware Description Release 1.2

Page 23: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-3UTStarcom TN780

DTC OverviewTable 2-1 on page 2-3 gives a list of DTC components, which are common to all DTCs, and the field replaceable circuit packs.

Front ViewA front view of the DTC, with components and circuit packs, is shown in Figure 2-1 on page 2-4.

Table 2-1 List of DTC hardware equipment

Equipment Type Name Description

DTC

components

Rack Mounting Ears See page 2-9Power Entry Modules (PEM) See page 2-10Input Output (I/O) Panel See page 2-12Timing and Alarm Panel (TAP) See page 2-15Fan Trays See page 2-22Air Filter See page 2-23

Circuit Packs Management Control Module (MCM) See page 2-25Band Mux Module (BMM) See page 2-31Digital Line Module (DLM) See page 2-42Tributary Adaptor Module 10G (TAM-2-10G) See page 2-47Tributary Adaptor Module 2.5G (TAM-4-2.5G) See page 2-51Tributary Adaptor Module 1G (TAM-4-1G) See page 2-55Tributary Optical Module 10G (TOM-10G-SR1) See page 2-55Tributary Optical Module 10G (TOM-10G-IR2) See page 2-61Tributary Optical Module 2.5G (TOM-2.5G-SR1) See page 2-61Tributary Optical Module 2.5G (TOM-2.5G-IR1) See page 2-67Tributary Optical Module 1G (TOM-1G-LX) See page 2-70

TN780 Hardware Description Release 1.2UTStarcom Inc.

Page 24: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-4 UTStarcom TN780Page 2-4

Figure 2-1 DTC front view

A single bay can accommodate two DTCs, and if needed, fiber management tray or DMC. Up to two TN780s, each with a single DTC, can be accommodated in a bay as shown in Figure 2-2 on page 2-5.

CableManagement

for IOP

CableManagement

for IOP

Fan Tray A

Fan Tray B

CableManagement

for TAP

Fiber GuideFiber Bend

Radius Control

Air InletPlenum

PEM A PEM B

IOP

BMMs

DLM Blanks

DLMs

MCM Blank

TAM Blanks

TAMs

Air Filter

MCM

TAP

UTStarcom Inc.TN780 Hardware Description Release 1.2

Page 25: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-5UTStarcom TN780

Figure 2-2 Two DTCs in a rack

Power Entry / I/O Shelf

Fan Shelf

Timing / Alarm Panel

DTC Card Cage

Fan Shelf

7’

20 U

Fits in 600mm or 23” rack

20 U

DCM or Fiber Tray

DCM or Fiber Tray

Power Entry / I/O Shelf

Fan Shelf

Timing / Alarm Panel

DTC Card Cage

Fan Shelf

UTStarcom Inc.

TN780 Hardware Description Release 1.2
Page 26: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-6 UTStarcom TN780Page 2-6

DTC CompliancyThe DTC complies with many industry standard specifications as described in Table 2-2 on page 2-6.

Table 2-2 DTC hardware compliancy

Category Approval Agency / Requirement

Safety Certifications • UL 60950: Safety of Information Technology Equipment

• CAN/CSA C22.2 No. 60950: Safety of Information Technology Equipment

• EN 60950 (Low Voltage Directive): Safety of Information Technology Equip-ment including electrical business equipment

• IEC 60950: Safety of Information Technology Equipment, including electrical business equipment

• TS001: Safety requirements for customer equipment

• AS/NZS 60950: Approval & Test specification -- Safety of information tech-nology equipment including electrical business equipment

NEBS/ETSI Compliancy • GR-1089-CORE: Electromagnetic Compatibility and Electrical Safety - Generic requirement for Network Telecommunications Equipment

• NEBS

• ETS 300 386

• GR-63-CORE: Network Equipment Building Systems -- Physical Protection

• ETS 300 019-2-1

• ETS 300 019-2-2

• ETS 300-019-2-3

• ETS 300 753

General Compliancy • ETSI ETS 300 119-4

• Telecordia GR-63-CORE

• Telecordia GR-78-CORE

• Telecordia GR-253-CORE

• ANSI T1.315-1994

• ANSI T1.304 1989

EMC Emissions • EN55022 Class A

EMC Immunity • EN61000-4-2,3,4,5,6

Laser Safety • EN60825 Series: Safety of Laser Products

• FDA21 CFR 1040: Performance Standard of Light Emitting Products

UTStarcom Inc.TN780 Hardware Description Release 1.2

Page 27: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-7UTStarcom TN780

DTC

Functional DescriptionThe DTC supports the following functions:

The DTC can be used as a Main Chassis or an Expansion Chassis within a TN780 network ele-ment.

The DTC is used in Digital Terminal, Digital Add/Drop and Digital Repeater configurations.

Each DTC supports up to 400Gbps bidirectional line side capacity and up to 400Gbps tributary drop capacity.

The DTC can be installed in a 23” rack or 600mmx600mm ETSI rack.

The DTC is comprised of the following components that provide power, perform system supervision, and enables system-level communication. Refer to Figure 2-1 on page 2-4 for an illustration of the DTC components.

Rack mounting ears (see“Rack Mounting Ears” on page 2-9)

Two Power Entry Modules (PEM) (see “Power Entry Module (PEM)” on page 2-10)

One I/O panel (see “I/O Panel” on page 2-12)

One Timing and Alarm Panel (TAP) (see “Timing and Alarm Panel (TAP)” on page 2-15)

Two fan trays (see “Fan Tray” on page 2-22)

One air filter (see “Air Filter” on page 2-23)

One card cage (see “Card Cage” on page 2-24)

The DTC contains three electrical ground locations. Two sets of two 1/4-20 press-nuts are located on the chassis at the rear bottom and two 1/4-20 press-nuts are located on each side toward the bottom front of the chassis. The rack mounting ears are the third grounding point.

Table 2-3 DTC product details

Product Number Product Description

DTC-ANSI-A Digital Transport Chassis ANSI

DTC-ETSI-A Digital Transport Chassis ETSI

TN780 Hardware Description Release 1.2UTStarcom Inc.

Page 28: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-8 UTStarcom TN780Page 2-8

Technical SpecificationsThe Table 2-4 on page 2-8 provides specification details for the DTC.

Table 2-4 DTC technical specifications

Type Parameter Specification

Mechanical specifications Height 34.95” / 888mm / 20RU / 35.5SU

Width 19.50” / 500mm

Depth 12.00” / 305mm (from faceplate)

Weight - w/PEMs, air filter, rack mounting ears, and door

88.5lbs

Weight - fully loaded chassis 240lbs

Electrical specifications Power consumption 2854W maximum

Input voltage range -40V DC to -60V DC

Environmental specifications Operating temperature range Normal: 5deg C to 40deg C

Short term: -5deg C to 55deg C

Storage temperature range -40deg C to 70deg C

High relative humidity 90% non-condensing

Compliance Environmental, EMI & safety NEBS Level 3, CE, IEC, ETSI, EN/IEC60950

UTStarcom Inc.TN780 Hardware Description Release 1.2

Page 29: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-9UTStarcom TN780

Figure 2-3 DTC dimensions

Rack Mounting EarsEach DTC includes flush rack mounting ears as an integral part of the chassis. The rack mounting ears are utilized to flush mount the chassis in a 23” rack or 600mmx600mm ETSI rack. Additionally, separate forward mount ears are provided to allow the chassis to mount 1”, 2”, 5”, and 6” forward from the front of the 23” rack.

When the rack mount ears are in the 5” back and 6” back positions for a forward mount configuration, the DTC uses slack managers to route the fiber-optic cables. There are three slack managers on each side of the DTC (six total) which maximizes valuable rack space and help to eliminate the pinching of cable in addition to providing correct cable bend radius. This ensures the system’s continual integrity and protection against signal loss or degradation.

Front View

23.50” (20.88”)22.312” (20.28”)

19.50”

34.95”

Top View

Back

Front

15.85”15.45”

12.0”

3.45”

TN780 Hardware Description Release 1.2UTStarcom Inc.

Page 30: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-10 UTStarcom TN780Page 2-10

Power Entry Module (PEM)The top position of the DTC accommodates two PEMs, PEM A and PEM B for redundant power feeds. Each PEM has a 70 Amp breaker for over-current protection on the power feed. See Figure 2-4 on page 2-10.

External Indicators

Figure 2-4 PEM faceplate

Power LEDsThe PEMs located on top of the chassis have two status LEDs: Power Input and Power Fault. The LEDs indicate whether the power levels are within specified limits. The significance of an illuminated LED is described in Table 2-5 on page 2-10.

ConnectorsEach PEM is provided with two sets of dual 1/4-20 studs on 5/8” centers. One set is for connection to -48V (-60V) Power and the second set to its Return. The studs are capable of accommodating industry standard

Table 2-5 Visual alarm indicators on the PEM

POWER INPUT

(Green)

POWER FAULT(Red) Description

ON OFF Input lead is receiving power.

Power output from the Power Entry Module as per specifications.

ON ON Input lead is receiving power.

Power output from Power Entry Module not to specifications.

Power Input LEDPower Fault LED

-48V Supply

Return Lead

On-Off Switch

70Amps rating-Circuit Breaker

UTStarcom Inc.TN780 Hardware Description Release 1.2

Page 31: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-11UTStarcom TN780

two-hole compression lugs on 5/8” centers. A plastic safety cover is provided to prevent inadvertent contact with the terminals once installed.

Technical SpecificationsThe Table 2-6 on page 2-11 provides the electrical, mechanical, environmental specifications and reliability data for the PEM.

Power Distribution ArchitecturePEM A and PEM B distributes the power supply to the power connectors on top of the backplane. The backplane feeds the power supply from each PEM to the circuit packs (see Figure 2-5 on page 2-12).

Table 2-6 PEM technical specifications

Type Parameter Specification

Mechanical specifications Height 3.7” / 94mm

Width 3.3” / 84mm

Depth 10.8” / 275mm

Weight 3lbs

Electrical specifications Power consumption 50W

Circuit breaker rating 70A

Input voltage range -40VDC to -60VDC

Environmental specifications Operating temperature range Normal: 5deg C to 40deg C

Short term: -5deg C to 55deg C

Storage temperature range -40deg C to 70deg C

High relative humidity 90% non-condensing

Compliance Environmental, EMI & safety NEBS Level 3, CE, IEC, ETSI, EN/IEC60950

TN780 Hardware Description Release 1.2UTStarcom Inc.

Page 32: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-12 UTStarcom TN780Page 2-12

Figure 2-5 Power distribution diagram

The DTC hardware modules combine the power feed by diode-ORing. The -48V inputs are individually fused on the circuit packs, I/O panel, TAP and fan trays to protect it from overcurrent conditions. The fuse is not field replaceable. The status of each fuse is monitored before the ORing diodes. A diode and a transorb are provided to protect against reverse polarity and transient overvoltage conditions.

I/O PanelThe I/O panel is part of the DTC. The I/O panel houses the management and operations interfaces as described below. The front view of the I/O panel is shown in Figure 2-6 on page 2-13.

Two 10/100Mb auto-negotiating Data Communication Network (DCN) RJ-45 interfaces, labeled as DCN

Two 10Mb Administrative Inter-LAN RJ-45 interfaces, labeled as AUX interface. This interface pro-vides Datawire services

Chassis level alarm LEDs (Power, Critical, Major, Minor)

Bay level alarm LEDs (Critical, Major, Minor)

Four inter-chassis interconnect RJ-45 interfaces referred to as Nodal Control and Timing (NCT), for multi-chassis configuration

One Lamp Test button

One Audible CutOff (ACO) button

One ACO LED

Craft RS232 Modem port

PEM B

-48V A

-48V B

BMM - slots 1 & 2

Timing & Alarm Panel

PEM A

DLM - slots 3 to 6 MCM - slots 7A & 7B

Fan Trays A & B

I/O Panel

UTStarcom Inc.TN780 Hardware Description Release 1.2

Page 33: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-13UTStarcom TN780

External Indicators

Figure 2-6 I/O panel front view

Bay-Level Alarm LEDsThe bay level indicators reflect the alarm status of all chassis in a bay. See Table 2-7 on page 2-13.

Note: Bay level indicators will only apply in a Multi-Chassis configuration.

Chassis-Level Alarm LEDsThe I/O panel has chassis level alarms, POWER, CRITICAL, MAJOR and MINOR LEDs. These indicate the severities of the current outstanding alarms within that chassis. The POWER LED indicates the power-

Table 2-7 Visual alarm indicators - bay level

LED Color Description

CRITICAL Red Indicates the presence (lit) or absence (dimmed) of Critical alarms in any of the chassis in the bay

MAJOR Red Indicates the presence (lit) or absence (dimmed) of Major alarms in any of the chas-sis in the bay

MINOR Yellow Indicates the presence (lit) or absence (dimmed) of Minor alarms in any of the chas-sis in the bay

Chassis alarms

Bay alarm LEdsRS 232 Modem port

RJ-45 DCN and Aux interfaces

RJ-45 interfaces for inter chassis connections

ControlTimingControlTiming

ACO button

Lamp test button

UTStarcom Inc.

TN 780 Hard ware Description Release 1.2
Page 34: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-14 UTStarcom TN780Page 2-14

on status. Each chassis has an ACO button on the alarm panel which controls the reporting of audible alarms. The significance of an illuminated LED is described in Table 2-8 on page 2-14.

Chassis-Level Audio IndicatorsThe TAP has output alarm contacts for CRITICAL, MAJOR and MINOR audible alarms. Audible alert is triggered when an alarm is raised on the chassis.

Alarm Cutoff IndicatorsThe I/O panel contains one ACO button and an ACO LED. The ACO feature allows muting of the audible alarms. When the ACO button is pressed, all current critical, major and minor audio alarms are muted and the ACO LED is lit. Table 2-9 on page 2-14, provides a description of the alarm state and the ACO LED state.

Lamp TestThe I/O panel contains a lamp test button for testing the LEDs. When the lamp test button is pressed, all LEDs on the I/O panel and the circuit packs on the chassis are lit for 10 seconds. After 10 seconds, all LEDs will return to the previous condition.

Table 2-8 Visual alarm indicators - chassis level

LED Color Description

POWER Green Indicates the presence (lit) or absence (dimmed) of power supply within the speci-fied operating range to the chassis

CRITICAL Red Indicates the presence (lit) or absence (dimmed) of Critical alarms in the chassis

MAJOR Red Indicates the presence (lit) or absence (dimmed) of Major alarms in the chassis

MINOR Yellow Indicates the presence (lit) or absence (dimmed) of Minor alarms in the chassis

ACO Yellow Indicates the alarm cut-off state

Table 2-9 Audio alarm indicators - chassis level

Condition ACO LED State Audio Alarm

There are no alarms on the chassis OFF Not present

An alarm is raised on the chassis OFF Present

ACO button is pressed ON Muted

An alarm is cleared OFF Not present

UTStarcom Inc.TN780 Hardware Description Release 1.2

Page 35: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-15UTStarcom TN780

ConnectorsThe I/O panel has a total of eight RJ-45 ports and one RS232 port.

Note: NCT ports are used for multi-chassis interconnection.

Timing and Alarm Panel (TAP)The TAP provides interfaces for external timing synchronization and environmental alarm contacts. The TAP does not contain any active component.

The TAP houses Telecordia and ITU Building Integrated Timing Supply (BITS) input and output timing interfaces. The BITS interfaces are labeled using the “A/B” convention for indicating paired interfaces. The configuration of the timing synchronization mode (T1 versus E1) determines which of the physical ports is referenced.

Note: The external timing synchronization is not supported in Release 1.2 .

The TAP also houses alarm input and output contact sets. The TAP has 20 alarm input contact sets. Each input alarm contact set has two contacts. Sixteen alarm input contact sets are user customizable, while the rest are reserved for Bay LED and ACO inputs from an external chassis. Refer to “Alarm input contact pin assignments” on page 2-17 for the list of the alarm contacts.

The TAP has 20 alarm output contact sets. Each output alarm contact set consists of Normally-closed, Normally-open and common contacts. Ten output contacts are user customizable, while the rest are reserved for office alarms and bay alarms. Refer to “Alarm output contact pin assignments” on page 2-18 for the list of the alarm contacts.

Table 2-10 I/O panel connectors

Connector Type Purpose

DCN A, DCN B 10/100Base-Tx Auto-MDIX RJ45

Two connectors with redundancy for remote management through DCN

AUX A, AUX B 10/100Base-Tx Auto-MDIX RJ45

Two connectors with redundancy for datawire service to carry customer management traffic

CRAFT DTE 57600 RS232 DTE DB9 Male

Allows remote management through a modem

NODAL CONTROL AND TIMING

100Base-Tx Auto-MDIX RJ45

Four connectors for Inter-chassis communication for uplink and downlink with A and B connectors for redun-dancy

TN780 Hardware Description Release 1.2UTStarcom Inc.

Page 36: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-16 UTStarcom TN780Page 2-16

External ConnectorsThe input and output dry alarm contacts of 0.045sq. inch pins are accessible from the front of the TAP to facilitate easy interconnection. These contacts are used for integration with existing environmental alarm systems. The alarm pin positions are shown in Figure 2-7 on page 2-16. The input and output connector details are given in Table 2-11 on page 2-16.

Figure 2-7 TAP front view

Technical SpecificationsThe environmental alarm contacts have the electrical ratings specified in Table 2-12 on page 2-16.

Table 2-11 TAP connectors

Connector Type Purpose

ALARM INPUTS 0.045sq. inch wire wrap pins

Environmental alarm inputs and office alarm input contacts

ALARM OUTPUTS 0.045sq. inch wire wrap pins

Environmental alarm output and office alarm output contacts

Table 2-12 Alarm relay contact specifications

Parameter Value

Maximum voltage 250V AC, 220V DC

Maximum current 2A

Rated load 0.5A @ 125V AC, 2A @ 30V DC

Wire size 24 AWG minimum

Maximum surge voltage between contact and coil 2,500V

Wire wrap pins for alarm inputs

Wire wrap pins for alarm outputs

TN780 Hardware Description Release 1.2

UTStarcom Inc.
Page 37: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-17UTStarcom TN780

Alarm Input Contact Pin AssignmentsTable 2-13 on page 2-17 specifies the assignment of alarm contact pins. Four alarm contacts are pre-defined in the system and the remaining sixteen contacts can be customized by the users to monitor environmental alarms.

Table 2-13 Alarm input contact pin assignments

Pin Description Function

Row Column

1 A Alarm Input Contact 1 User defined

1 B Alarm Input Contact 1 User defined

1 C Alarm Input Contact 5 User defined

1 D Alarm Input Contact 5 User defined

1 E Alarm Input Contact 9 User defined

1 F Alarm Input Contact 9 User defined

1 G Alarm Input Contact 13 User defined

1 H Alarm Input Contact 13 User defined

1 I Reserved for Critical Bay alarm Predefined

1 J Reserved for Critical Bay alarm Predefined

2 A Alarm Input Contact 2 User defined

2 B Alarm Input Contact 2 User defined

2 C Alarm Input Contact 6 User defined

2 D Alarm Input Contact 6 User defined

2 E Alarm Input Contact 10 User defined

2 F Alarm Input Contact 10 User defined

2 G Alarm Input Contact 14 User defined

2 H Alarm Input Contact 14 User defined

2 I Reserved for Major Bay alarm Predefined

2 J Reserved for Major Bay alarm Predefined

3 A Alarm Input Contact 3 User defined

3 B Alarm Input Contact 3 User defined

3 C Alarm Input Contact 7 User defined

3 D Alarm Input Contact 7 User defined

3 E Alarm Input Contact 11 User defined

3 F Alarm Input Contact 11 User defined

3 G Alarm Input Contact 15 User defined

3 H Alarm Input Contact 15 User defined

3 I Reserved for Minor Bay alarm Predefined

TN780 Hardware Description Release 1.2UTStarcom Inc.

Page 38: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-18 UTStarcom TN780Page 2-18

Alarm Output Contact Pin AssignmentsThe contact pin specification for alarm outputs are described in Table 2-14 on page 2-18. Ten alarm contacts are pre-defined in the system and the remaining ten contacts can be customized by the users to monitor the environmental alarms.

3 J Reserved for Minor Bay alarm Predefined

4 A Alarm Input Contact 4 User defined

4 B Alarm Input Contact 4 User defined

4 C Alarm Input Contact 8 User defined

4 D Alarm Input Contact 8 User defined

4 E Alarm Input Contact 12 User defined

4 F Alarm Input Contact 12 User defined

4 G Alarm Input Contact 16 User defined

4 H Alarm Input Contact 16 User defined

4 I Reserved for Alarm cut-off Predefined

4 J Reserved for Alarm cut-off Predefined

Table 2-14 Alarm output contact pin assignments

Pin Description Function

Row Column

1 K Alarm Output Contact 1,

RETURN

User defined

1 L Alarm Output Contact 1,

NORMALLY OPEN

User defined

1 M Alarm Output Contact 1,

NORMALLY CLOSED

User defined

1 N Alarm Output Contact 5,

RETURN

User defined

1 O Alarm Output Contact 5,

NORMALLY OPEN

User defined

1 P Alarm Output Contact 5,

NORMALLY CLOSED

User defined

1 Q Alarm Output Contact 9,

RETURN

User defined

Table 2-13 Alarm input contact pin assignments

Pin Description Function

UTStarcom Inc.TN780 Hardware Description Release 1.2

Page 39: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-19UTStarcom TN780

1 R Alarm Output Contact 9,

NORMALLY OPEN

User defined

1 S Alarm Output Contact 9,

NORMALLY CLOSED

User defined

1 T Minor Audio Alarm,

RETURN

Predefined

1 U Minor Audio Alarm,

NORMALLY OPEN

Predefined

1 V Minor Audio Alarm,

NORMALLY CLOSED

Predefined

1 W Power Fault Bay Alarm,

RETURN

Predefined

1 X Power Fault Bay Alarm,

NORMALLY OPENa

Predefined

1 Y Power Fault Bay Alarm,

NORMALLY CLOSEDa

Predefined

2 K Alarm Output Contact 2,

RETURN

User defined

2 L Alarm Output Contact 2,

NORMALLY OPEN

User defined

2 M Alarm Output Contact 2,

NORMALLY CLOSED

User defined

2 N Alarm Output Contact 6,

RETURN

User defined

2 O Alarm Output Contact 6,

NORMALLY OPEN

User defined

2 P Alarm Output Contact 6,

NORMALLY CLOSED

User defined

2 Q Alarm Output Contact 10,

RETURN

User defined

2 R Alarm Output Contact 10,

NORMALLY OPEN

User defined

2 S Alarm Output Contact 10,

NORMALLY CLOSED

User defined

Table 2-14 Alarm output contact pin assignments

Pin Description Function

TN780 Hardware Description Release 1.2UTStarcom Inc.

Page 40: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-20 UTStarcom TN780Page 2-20

2 T Critical Visual Alarm,

RETURN

Predefined

2 U Critical Visual Alarm,

NORMALLY OPEN

Predefined

2 V Critical Visual Alarm,

NORMALLY CLOSED

Predefined

2 W Critical Bay Alarm,

RETURN

Predefined

2 X Critical Bay Alarm,

NORMALLY OPEN

Predefined

2 Y Critical Bay Alarm,

NORMALLY CLOSED

Predefined

3 K Alarm Output Contact 3,

RETURN

User defined

3 L Alarm Output Contact 3,

NORMALLY OPEN

User defined

3 M Alarm Output Contact 3,

NORMALLY CLOSED

User defined

3 N Alarm Output Contact 7,

RETURN

User defined

3 O Alarm Output Contact 7,

NORMALLY OPEN

User defined

3 P Alarm Output Contact 7,

NORMALLY CLOSED

User defined

3 Q Critical Audio Alarm,

RETURN

Predefined

3 R Critical Audio Alarm,

NORMALLY OPEN

Predefined

3 S Critical Audio Alarm,

NORMALLY CLOSED

Predefined

3 T Major Visual Alarm,

RETURN

Predefined

3 U Major Visual Alarm,

NORMALLY OPEN

Predefined

Table 2-14 Alarm output contact pin assignments

Pin Description Function

UTStarcom Inc.TN780 Hardware Description Release 1.2

Page 41: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-21UTStarcom TN780

3 V Major Visual Alarm,

NORMALLY CLOSED

Predefined

3 W Major Bay Alarm,

RETURN

Predefined

3 X Major Bay Alarm,

NORMALLY OPEN

Predefined

3 Y Major Bay Alarm,

NORMALLY CLOSED

Predefined

4 K Alarm Output Contact 4,

RETURN

User defined

4 L Alarm Output Contact 4,

NORMALLY OPEN

User defined

4 M Alarm Output Contact 4,

NORMALLY CLOSED

User defined

4 N Alarm Output Contact 8,

RETURN

User defined

4 O Alarm Output Contact 8,

NORMALLY OPEN

User defined

4 P Alarm Output Contact 8,

NORMALLY CLOSED

User defined

4 Q Major Audio Alarm,

RETURN

Predefined

4 R Major Audio Alarm,

NORMALLY OPEN

Predefined

4 S Major Audio Alarm,

NORMALLY CLOSED

Predefined

4 T Minor Visual Alarm,

RETURN

Predefined

4 U Minor Visual Alarm,

NORMALLY OPEN

Predefined

4 V Minor Visual Alarm,

NORMALLY CLOSED

Predefined

4 W Minor Bay Alarm,

RETURN

Predefined

Table 2-14 Alarm output contact pin assignments

Pin Description Function

TN780 Hardware Description Release 1.2UTStarcom Inc.

Page 42: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-22 UTStarcom TN780Page 2-22

Fan TrayThe DTC contains two removable fan trays. Each fan tray consists of three individually controlled fans. The top fan tray is referred to as Fan Shelf A, and the bottom tray is referred to as Fan Shelf B. The thermal system employs a push-pull approach to move air through the system. The air flow enters from the bottom front and sides and exits from the top rear and sides.

Both fan trays are required for normal operations and are not redundant. However, individual fans, within a fan tray, are N +1 redundant with power hot-swap controllers. In the event of a single fan failure (within a fan tray), with the remaining fans running at full speed, the chassis will operate in normal room temperature, without one tray, for up to 60 minutes. A single fan failure within a fan tray will trigger an alarm for replacement of the fan tray.

A POWER LED and a FAULT LED are provided on each fan tray. The significance of an illuminated LED is described in Table 2-15 on page 2-22

4 X Minor Bay Alarm,

NORMALLY OPEN

Predefined

4 Y Minor Bay Alarm,

NORMALLY CLOSED

Predefined

a. When there is no power fault condition, the Normally Open contact is closed and the Normally Close contact is open. When both PEM-A and PEM-B have power fault condition, the Normally Open contact is open and Normally Close contact is closed. The power fault is defined as when the power input into PEM-A or PEM-B is out of working range.

Table 2-15 Visual alarm indicators on the fan tray

LED Color Description

POWER Green Indicates the presence or absence of power supply to the fan tray

FAULT Red Indicates the fault status of the fan tray

Table 2-14 Alarm output contact pin assignments

Pin Description Function

UTStarcom Inc.TN780 Hardware Description Release 1.2

Page 43: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-23UTStarcom TN780

Technical SpecificationsTable 2-16 on page 2-23 provides the electrical, mechanical, environmental specifications and reliability data for the fan shelf.

Air FilterA replacable air filter is located below the bottom fan tray to filter out dust particles at the air intake of the DTC. Air is filtered at 80% dust arrestance. Depending upon the operational environment, the air filters have to be replaced at regular intervals, preferably once in 3 months.

Table 2-16 Fan tray technical specifications

Type Parameter Specification

Mechanical specifications Height 2.15” / 55mm

Width 19.3” / 490mm

Depth 10.53” / 268mm

Weight 11lbs

Electrical specifications Power consumption 380W

Input voltage range -40V DC to -60V DC

Environmental specifications Operating temperature range Normal: 5deg C to 40deg C

Short term: -5deg C to 55deg C

Storage temperature range -40deg C to 70deg C

High relative humidity 90% non-condensing

Compliance Environmental, EMI & safety NEBS Level 3, CE, IEC, ETSI, EN/IEC60950

TN780 Hardware Description Release 1.2UTStarcom Inc.

Page 44: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-24 UTStarcom TN780Page 2-24

Technical Specifications

Card CageThe DTC contains a single card cage. The DTC has seven slots and houses the circuit packs (see Table 2-18 on page 2-24) that provides the optical and digital transport functions of the system.

Table 2-17 Air filter technical specifications

Type Parameter Specification

Mechanical specifications Height 0.72” / 18mm

Width 19.35” / 492mm

Depth 9.7” / 247mm

Weight less than 0.5lbs

Dust arrestance 80%

Compliance Fire rating UL Class II

Table 2-18 DTC circuit pack assignments

Circuit Pack Name Abbreviation Reserved Slot numbers in the DTC

Management Control Module MCM Slot numbers 7A and 7B

Band Mux Module BMM Slot numbers 1 and 2

Digital Line Module DLM Slot numbers 3, 4, 5 and 6

Tributary Adapter Module 10G TAM 10G In any one of the five sub-slots of a DLM

Tributary Adapter Module 2.5G TAM 2.5G In any one of the five sub-slots of a DLM

Tributary Adapter Module 1G TAM 1G In any one of the five sub-slots of a DLM

Tributary Optical Module 10G TOM 10G In any one of the two sub-slots of a TAM 10G

Tributary Optical Module 2.5G TOM 2.5G In any one of the four sub-slots of a TAM 2.5G

Tributary Optical Module 1G TOM 1G In any one of the four sub-slots of a TAM 1G

UTStarcom Inc.TN780 Hardware Description Release 1.2

Page 45: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-25UTStarcom TN780

Management Control Module (MCM)

There are two types of MCMs available for managing a TN780, the MCM-A and MCM-B. The parameter differences between the two modules are shown in Table 2-20 on page 2-25

Table 2-20 MCM-A and MCM-B differences

MCM-A Functional DescriptionThe MCM-A, is a half height module that slides into the chassis in slot 7A or slot 7B. The MCM-A is the shelf controller of all the modules resident within the DTC.The functions are:

Management gateway functions to the external DCN in the Main Chassis

Contains the software, and the database for the TN780

Note: In Release 1.2 the MCM-A can be deployed in a single-chassis system only.

Note: The MCM-A will be supported in non-redundant configurations only.

Note: The MCM-A and a MCM-B should not be located in the same chassis.For the procedure to upgrade from a MCM-A to a MCM-B refer to the UTStarcom TN780 Maintenance and Troubleshooting Guide.

Table 2-19 MCM product details

Product Number Product Description

MCM-A Management and Control Module-A

MCM-B Management and Control Module-B

Parameter MCM-A MCM-B

CPU Frequency 400 Mhz 466 Mhz

Persistence Storage 256 Mbytes 1 Gbytes

Physical Memory (SDRAM)

256 Mbytes 512 Mbytes

TN780 Hardware Description Release 1.2UTStarcom Inc.

Page 46: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-26 UTStarcom TN780Page 2-26

MCM-B Functional DescriptionThe MCM-B, is a half height module that slides into the chassis in slot 7A or slot 7B. The MCM-B is the shelf controller of all the modules resident within the DTC.The functions are:

In a multi-chassis configuration, the MCM-B in the Main Chassis controls all the chassis within the TN780 network element

The MCM-B in the Expansion chassis performs shelf controller functions controlling only the mod-ules resident within that chassis

Management gateway functions to the external DCN in the Main Chassis

Contains the software, and the database for the TN780

The MCM-Bs in the Main Chassis and Expansion Chassis are interconnected through NCT ports located on the I/O Panel.

The MCM-B supports the local craft interfaces for local management access.

For high-availability, redundant MCM-Bs can be deployed in each DTC. One MCM-B actively performs the node/shelf control functions while the other MCM-B is in the standby mode. In a multi-chassis configuration, the interconnected redundant MCM-Bs provide the inter-chassis redundancy.

Note: In a Multi-Chassis configuration the DCN ports on the Main Chassis are active. The DCN ports on the Expansion Chassis are disabled.

UTStarcom Inc.TN780 Hardware Description Release 1.2

Page 47: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-27UTStarcom TN780

Block Diagram

Figure 2-8 MCM functional block diagram

External Indicators and ConnectorsThe MCM has circuit pack status LED indicators and craft Ethernet/Serial port connectors on the front panel as shown in Figure 2-9 on page 2-28.

CPU

RTC & NVRAMNAND Flash

EthernetSwitch

Telemetry

Front panelCraft serial

Fan controls

Front panelCraft

Ethernet

Modem

Display controls

Flash RAM

1-wire controls

Control and status

Timing controls and distribution

Bay alarm LED

Chassis alarm

IO RelayFan A

Fan B

IO panelPeer MCM switch

IO, Backplane and fans

Peer MCM, DLM and BMM

Peer MCM, DLM and BMM

Peer MCM, DLM and BMM

Bay alarm LED

Chassis alarm

IO RelayFan A

Fan B

IO panelPeer MCM switch

IO, Backplane and fans

Peer MCM, DLM and BMM

Peer MCM, DLM and BMM

Peer MCM, DLM and BMM

Bac

kplane

Con

nector

TN780 Hardware Description Release 1.2UTStarcom Inc.

Page 48: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-28 UTStarcom TN780Page 2-28

Figure 2-9 MCM faceplate

Ejector

Circuit Pack Status LEDs

Craft Ethernet Port

Craft RS 232 Serial Port

Ejector

CraftEthernet

StatusLEDs

TN780 Hardware Description R

UTStarcom Inc.elease 1.2
Page 49: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-29UTStarcom TN780

Circuit Pack Level LEDsThe MCM has 4 LEDs to indicate the circuit pack status as described in Table 2-21 on page 2-29.

Note: On the MCM-A, the NC and ACT LED will be green. The MCM-A does not support multi-chassis, or redundant configurations.

ConnectorsThe MCM has craft Ethernet and craft serial ports for management purposes (see Table 2-22 on page 2-29).

Table 2-21 MCM status LED indicators

LED Indicator Color Meaning

PWR (Power) Green Indicates the presence (lit) or absence (dimmed) of power supply to the MCM circuit pack

NC (Node Controller) Green Indicates the chassis function: Main Chassis or Expansion chassis

ACT (Active) Green / Yellow Indicates the circuit pack status: Active or Standby

FLT (Fault) Red Indicates the presence (lit) or absence (dimmed) of an alarm on the circuit pack: Critical, Major or Minor

Table 2-22 MCM connectors

Connector Type Purpose

CRAFT10Base-T 10/100Base-Tx Auto-MDIX RJ45

Used by maintenance personnel for managing the network element locally

CRAFT DCE 9600 RS232 DCE DB9 Female

Used by maintenance personnel for managing the network element locally

TN780 Hardware Description Release 1.2UTStarcom Inc.

Page 50: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-30 UTStarcom TN780Page 2-30

Technical SpecificationsTable 2-23 on page 2-30 provides the electrical, mechanical, environmental specifications and reliability data for the MCM.

Table 2-23 MCM technical specifications

Type Parameter Specification

Mechanical specifications Height 8.95” / 227mm

Width 1.0” / 254mm

Depth 11.1” / 282mm

Weight 2.75lbs

Electrical specifications Power consumption 35W (maximum for each)

Input voltage range -40V DC to -60V DC

Environmental specifications Operating temperature range Normal: 5deg C to 40deg C

Short term: -5deg C to 55deg C

Storage temperature range -40deg C to 70deg C

High relative humidity 90% non-condensing

Compliance Environmental, EMI & safety NEBS Level 3, CE, IEC, ETSI, EN/IEC60950

UTStarcom Inc.TN780 Hardware Description Release 1.2

Page 51: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-31UTStarcom TN780

Band Mux Module (BMM)There are 9 different BMM types providing Optical Channel Groups (OCG), EDFA gain, and with/without mid-stage access. Table 2-24 on page 2-31 provides the name and the function of each of the available BMMs.

BMM-4-CX-XX-A Functional DescriptionThe BMM-4-A can be equipped in the slots 1 and / or slot 2 of the DTC. A BMM-4-A performs the following functions:

Optically multiplexes four 10x10Gb DWDM channels from the DLMs, known as Optical Carrier Groups (OCGs), onto the line side facility

OCGs 1, 3, 5, and 7 can be optically multiplexed by the BMM

Optically de-multiplexes the OCGs from the line side facility into 10x10Gb DWDM channels, and passes them to local DLMs

OCGs 1, 3, 5, and 7 can be optically de-multiplexed by the BMM

Provides optical insertion and extraction of the 1510nm Optical Supervisory Channel by using a 1510nm optical filter

Table 2-24 BMM product details

Product Number Product Description

BMM-4-C1-A BMM, C band, 20 dB fixed gain, with VOA, without mid-stage access, supports OCGs 1,3,5,and 7

BMM-4-C1-B BMM, C band, 20 dB fixed gain, with VOA, without mid-stage access, supports OCGs 1,3,5,and 7

BMM-8-C1-A BMM, C band, 20 dB fixed gain, with VOA, without mid-stage access, supports OCGs 1-8

BMM-4-C2-MS-A BMM, C band, variable gain from 18 dB to 26 dB, with mid-stage access, supports OCGs 1,3,5,and 7

BMM-4-C2-MS-B BMM, C band, variable gain from 18 dB to 26 dB, with mid-stage access, supports OCGs 1,3,5,and 7

BMM-8-C2-MS-A BMM, C band, variable gain from 18 dB to 26 dB, with mid-stage access, supports OCGs 1-8

BMM-4-C3-MS-A BMM, C band, variable gain from 25 dB to 33 dB, with mid-stage access, supports OCGs 1,3,5,and 7

BMM-4-C3-MS-B BMM, C band, variable gain from 25 dB to 33 dB, with mid-stage access, supports OCGs 1,3,5,and 7

BMM-8-C3-MS-A BMM, C band, variable gain from 25 dB to 33 dB, with mid-stage access, supports OCGs 1-8

TN780 Hardware Description Release 1.2UTStarcom Inc.

Page 52: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-32 UTStarcom TN780Page 2-32

Optically amplifies the multiplexed transmitted and received OCG signals by using either an optical booster or a pre-amplifier

Provides a C/L-band splitter to support an in-service expansion of the system to enable optical trans-mission in the L-band

Provides the following Optical Spectrum Analyzer (OSA) ports for test purposes:

OSA port for the aggregate line input

OSA port for the receive EDFA output

OSA port for the aggregate line output

Provides sub-slot access for the OWM (future provision)

Accommodates mid-stage access Dispersion Compensation Fiber (DCF) in 2 versions of the BMM-4

Note: If the mid-stage DCF is between 0 and 800 ps/nm, the addition of a 5dB attenuator is required for normal operations.

Note: If the mid-stage DCF is above 800 ps/nm then there is no requirement for the 5dB attenua-tor.

BMM-4-CX-XX-B Functional DescriptionThe BMM-4-B can be equipped in the slots 1 and / or slot 2 of the DTC. A BMM-4-A performs the following functions:

Has an enhanced EDFA for increased reliability

Optically multiplexes four 10x10Gb DWDM channels from the DLMs, known as Optical Carrier Groups (OCGs), onto the line side facility

OCGs 1, 3, 5, and 7 can be optically multiplexed by the BMM

Optically de-multiplexes the OCGs from the line side facility into 10x10Gb DWDM channels, and passes them to local DLMs

OCGs 1, 3, 5, and 7 can be optically de-multiplexed by the BMM

Provides optical insertion and extraction of the 1510nm Optical Supervisory Channel by using a 1510nm optical filter

Optically amplifies the multiplexed transmitted and received OCG signals by using either an optical booster or a pre-amplifier

Provides a C/L-band splitter to support an in-service expansion of the system to enable optical trans-mission in the L-band

Provides the following Optical Spectrum Analyzer (OSA) ports for test purposes:

UTStarcom Inc.TN780 Hardware Description Release 1.2

Page 53: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-33UTStarcom TN780

OSA port for the aggregate line input

OSA port for the receive EDFA output

OSA port for the aggregate line output

Provides sub-slot access for the OWM (future provision)

Accommodates mid-stage access Dispersion Compensation Fiber (DCF) in 2 versions of the BMM-4-B

Note: The enhanced EDFA eliminates the need for a 5b attenuator on the DCM port.

BMM-8 Functional Description

Note: The limited availability of the 80 channel BMM-8 will allow deployment of equipment that will support 800Gbps in future releases. Please contact your UTStarcom sales account team for more information.

Note: At this time, DLMs to support the incremental 40 channels (DLM 2, 4,6, and 8) are in devel-opment but not yet released.

The BMM-8 can be equipped in the slots 1 and / or slot 2 of the DTC. A BMM-8 performs the following functions:

Has an enhanced EDFA for increased reliability

Optically multiplexes eight 10x10Gb DWDM channels from the DLMs, known as OCGs, onto the line side facility

OCGs 1-8 can be optically multiplexed by the BMM

Optically de-multiplexes the OCGs from the line side facility into 10x10Gb DWDM channels, and passes them to local DLMs

OCGs 1-8 can be optically de-multiplexed by the BMM

Provides optical insertion and extraction of the 1510nm Optical Supervisory Channel by using a 1510nm optical filter

Optically amplifies the multiplexed transmitted and received OCG signals by using either an optical booster or a pre-amplifier

Provides a C/L-band splitter to support an in-service expansion of the system to enable optical transmission in the L-band

Provides the following OSA ports for test purposes:

OSA port for the aggregate line input

TN780 Hardware Description Release 1.2UTStarcom Inc.

Page 54: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-34 UTStarcom TN780Page 2-34

OSA port for the receive EDFA output

OSA port for the aggregate line output

Provides sub-slot access for the OWM circuit pack (future provision)

Accommodates mid-stage access DCF in 2 versions of the BMM-8

Note: The enhanced EDFA eliminates the need for a 5b attenuator on the DCM port.

UTStarcom Inc.TN780 Hardware Description Release 1.2

Page 55: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-35UTStarcom TN780

Block Diagram

Figure 2-10 BMM control plane block diagram

Figure 2-11 BMM-4 data plane block diagram

CPU

Bac

kpla

ne C

onne

ctor

Flash RAM

10 / 100 Ethernet

Transceiver

10 / 100 Ethernet

Transceiver

OWM

EthernetSwitch

STS-3C / FE Mapper

OSC Transceiver

OW

M C

onne

ctor

CPU

Bac

kpla

ne C

onne

ctor

Flash RAM

10 / 100 Ethernet

Transceiver

10 / 100 Ethernet

Transceiver

OWM

EthernetSwitch

STS-3C / FE Mapper

OSC Transceiver

OW

M C

onne

ctor

OCG 1

OCG 3

OCG 5

OCG 7

SC

SC

SC

SC

SC

SC

SC

VOA

MUX

DE-MUX

MUX

DE-MUX

OUT

L-Band

IN

SC

SC

OSA monitor IN

OSA monitor OUT

SC

IN OUTDCM

SC

OSA RX AMP OUT

Rx-EDFA

Tx-EDFA

OSC Tx

OSC Rx

INOUT

INOUT

INOUT

INOUT

INOUT LINE

MUX

DE-MUX

Optional

OCG 1

OCG 3

OCG 5

OCG 7

SC

SC

SC

SC

SC

SC

SC

VOA

MUX

DE-MUX

MUX

DE-MUX

OUT

L-Band

IN

SC

SC

OSA monitor IN

OSA monitor OUT

SC

IN OUTDCM

SC

OSA RX AMP OUT

Rx-EDFA

Tx-EDFA

OSC Tx

OSC Rx

INOUT

INOUT

INOUT

INOUT

INOUT LINE

MUX

DE-MUX

Optional

TN780 Hardware Description Release 1.2UTStarcom Inc.

Page 56: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-36 UTStarcom TN780Page 2-36

External Indicators and ConnectorsThe BMM-4 has circuit pack status LED indicators and craft Ethernet/Serial port connectors (see Figure 2-12 on page 2-36).

Figure 2-12 BMM-4 faceplate

Ejector

Ejector

OWM Circuit Pack

OCG 1 Connectors

OCG 3 Connectors

OCG 5 Connectors

OCG 7 Connectors

PWRACTFLT

ACTLOSPort LEDs

CircuitPack

StatusLEDs

INVISIBLE LASERRADIATION

DO NOT VIEWDIRECTLY WITH

OPTICALINSTRUMENTS

CLASS 1M LASERPRODUCT (IEC)CLASS I LASER

PRODUCT (CDRH)1550nm-50mW

Warning Label

Line connectors

OSA Monitor Connector for line input and output

OSA monitor port for facility output (to DLM)

L-Band Connectors

DCM Connectors(Present only in BMM-4-C2-MS and BMM-4-C3-MS)

(Future provision)

TN780 Hardware Description Release 1.2

UTStarcom Inc.
Page 57: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-37UTStarcom TN780

Circuit Pack Level LEDsThe BMM has 3 LEDs to indicate the circuit pack status. The significance of an illuminated LED is described in Table 2-25 on page 2-37.

Port IndicatorsThere are two LEDs: ACTIVE and LOS for the BMM circuit pack to indicate the line port status.The significance of an illuminated LED is described in Table 2-26 on page 2-37.

ConnectorsThe BMM-4 has connectors for the external fiber plant and for management and control traffic (see Table 2-27 on page 2-37).

Table 2-25 BMM status LED indicators

LED Indicator Color Meaning

PWR (Power) Green Indicates the presence (lit) or absence (dimmed) of power supply to the BMM circuit pack

ACT (Active) Green / Yellow Indicates the circuit pack status: Active or Standby

FLT (Fault) Red Indicates the presence (lit) or absence (dimmed) of an alarm on the circuit pack: Critical, Major or Minor

Table 2-26 Port visual alarm indicators on BMM circuit pack

LED State Description

ACT (Active) Green / Yellow Indicates the line port administrative status

LOS Red Indicates the incoming signal or port configuration status

Table 2-27 BMM-4 connectors

Connector Type Purpose

Line IN SC, Front access Connects from the line side fibers

Line OUT SC, Front access Connects to the line side fibers

OSA Monitor IN SC, Front access Port to monitor line input

OSA Monitor OUT SC, Front access Port to monitor line output

OSA Monitor OUT SC, Front access Port to monitor power

L-Band IN SC, Front access Port used to pass L-band channels

L-Band OUT SC, Front access Port used to pass L-band channels

DCM IN SC, Front access Connects from the DCM

TN780 Hardware Description Release 1.2UTStarcom Inc.

Page 58: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-38 UTStarcom TN780Page 2-38

DCM OUT SC, Front access Connects to the DCM

OCG 1 IN SC, Front access Connects from the DLM-1-C1

OCG 1 OUT SC, Front access Connects to the DLM-1-C1

OCG 3 IN SC, Front access Connects from the DLM-1-C3

OCG 3 OUT SC, Front access Connects to the DLM-1-C3

OCG 5 IN SC, Front access Connects from the DLM-1-C5

OCG 5 OUT SC, Front access Connects to the DLM-1-C5

OCG 7 IN SC, Front access Connects from the DLM-1-C7

OCG 7 OUT SC, Front access Connects to the DLM-1-C7

Table 2-27 BMM-4 connectors

Connector Type Purpose

UTStarcom Inc.TN780 Hardware Description Release 1.2

Page 59: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-39UTStarcom TN780

Table 2-28 BMM-8 Connectors

Note: DLM-2, DLM-4, DLM-6, and DLM-8 will be available in a future release.

Connector Type Purpose

Line IN SC, Front access Connects from the line side fibers

Line OUT SC, Front access Connects to the line side fibers

OSA Monitor IN SC, Front access Port to monitor line input

OSA Monitor OUT SC, Front access Port to monitor line output

OSA Monitor OUT SC, Front access Port to monitor power

L-Band IN SC, Front access Port used to pass L-band channels

L-Band OUT SC, Front access Port used to pass L-band channels

DCM IN SC, Front access Connects from the DCM

DCM OUT SC, Front access Connects to the DCM

OCG 1 IN SC, Front access Connects from the DLM-1-C1

OCG 1 OUT SC, Front access Connects to the DLM-1-C1

OCG 2 IN SC, Front access Connects from the DLM-2-C1

OCG 2 OUT SC, Front access Connects to the DLM-2-C1

OCG 3 IN SC, Front access Connects from the DLM-3-C1

OCG 3 OUT SC, Front access Connects to the DLM-3-C1

OCG 4 IN SC, Front access Connects from the DLM-4-C1

OCG 4 OUT SC, Front access Connects to the DLM-4-C1

OCG 5 IN SC, Front access Connects from the DLM-5-C1

OCG 5 OUT SC, Front access Connects to the DLM-5-C1

OCG 6 IN SC, Front access Connects from the DLM-6-C1

OCG 6 OUT SC, Front access Connects to the DLM-6-C1

OCG 7 IN SC, Front access Connects from the DLM-7-C1

OCG 7 OUT SC, Front access Connects to the DLM-7-C1

OCG 8 IN SC, Front access Connects from the DLM-8-C1

OCG 8 OUT SC, Front access Connects to the DLM-8-C1

TN780 Hardware Description Release 1.2UTStarcom Inc.

Page 60: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-40 UTStarcom TN780Page 2-40

Technical SpecificationsTable 2-29 on page 2-40 provides the electrical, mechanical, environmental specifications and reliability data for BMM-4.

The optical specification details for the BMM- 4 are listed in Table 2-30 on page 2-40.

Table 2-29 BMM technical specifications

Type Parameter Specification

Mechanical specifications Height 18.5” / 470mm

Width 2.0” / 51mm

Depth 11.1” / 282mm

Weight 10.5lbs (approx)

Electrical specifications Power dissipation 86W

Input voltage range -40V DC to -60V DC

Environmental specifications Operating temperature range Normal: 5deg C to 40deg C

Short term: -5deg C to 55deg C

Storage temperature range -40deg C to 70deg C

High relative humidity 90% non-condensing

Compliance Environmental, EMI & safety NEBS Level 3, CE, IEC, ETSI, EN/IEC60950

Laser safety ANSI Class I, IEC Class 1M

Table 2-30 BMM-4 optical specifications

Type Parameter Specification

Line side optics Wavelength spacing 100GHz

Wavelength frequency range 1530.725-1563.455nm ITU Grid

OSC Wavelength 1510nm

Format OC-3

UTStarcom Inc.TN780 Hardware Description Release 1.2

Page 61: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-41UTStarcom TN780

The optical specification details for the BMM-8 are listed in Table 2-31 on page 2-41

Table 2-31 BMM-8 Optical Specifications

Type Parameter Specification

Line side optics Wavelength spacing 50GHz

Wavelength frequency range 1530.334-1563.455nm ITU Grid

OSC Wavelength 1510nm

Format OC-3

TN780 Hardware Description Release 1.2UTStarcom Inc.

Page 62: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-42 UTStarcom TN780Page 2-42

Digital Line Module (DLM)There are four versions of DLMs, with four OCGs as shown in Table 2-32 on page 2-42.

Functional DescriptionThe Digital Line Module, referred to as DLM, performs the following functions:

Provides add/drop or switching of 2.5Gb/s, 10Gb/s, or 1Gb/s signals between TAMs, wavelengths on the OCG uplink, and peered DLMs across the backplane

Maps and multiplexes the client signals from the TAM circuit packs into the Digital Transport Frame (DTF) that are transmitted and received from the OCG OUT and OCG IN links on each DLM

Codes and decodes the Forward Error Correction (FEC) signal for each wavelength of the OCG transmitted through the Tx and Rx Photonic Integrated Circuits (PICs)

Optically connects to the appropriate BMM for transmission over the facility line side

Applies FEC for each channel transmitted between DLM and BMM

The DLM circuit packs can be equipped in slots 3 through 6.

Table 2-32 DLM product details

Product Number Product Description

DLM-1-C1-A DLM, OCG 1, C-Band, Type 1

DLM-3-C1-A DLM, OCG 3, C-Band, Type 1

DLM-5-C1-A DLM, OCG 5, C-Band, Type 1

DLM-7-C1-A DLM, OCG 7, C-Band, Type 1

UTStarcom Inc.TN780 Hardware Description Release 1.2

Page 63: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-43UTStarcom TN780

Block Diagram

Figure 2-13 DLM functional block diagram

TAM

FEC / DTF Mapper

FEC / DTF Mapper

Wavelength locker

Tx PIC

Cross point

PIC Controller

VOA

OCG

Facility clock ref

System clock ref

CPU

Data

Plane

Con

nector

Ether

net C

onne

ctor

OUT

IN

Flash

RAM10 / 100 Ethernet

Transceiver

10 / 100 Ethernet

Transceiver

Front panel LEDs

LEDs

Midplan

e Con

nector

Rx PIC TAMTAMTAM

FEC / DTF Mapper

FEC / DTF Mapper

FEC / DTF Mapper

FEC / DTF Mapper

Wavelength locker

Tx PIC

Cross point

PIC Controller

VOA

OCG

Facility clock ref

System clock ref

CPU

Data

Plane

Con

nector

Ether

net C

onne

ctor

OUT

IN

Flash

RAM10 / 100 Ethernet

Transceiver

10 / 100 Ethernet

Transceiver

Front panel LEDs

LEDs

Midplan

e Con

nector

Rx PIC TAMTAM

TN780 Hardware Description Release 1.2UTStarcom Inc.

Page 64: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-44 UTStarcom TN780Page 2-44

External Indicators and Connectors

Figure 2-14 DLM faceplate

Ejector

Ejector

TAM Blank Circuit Pack 1

Line Connectors

Circuit Pack Status LEDsPWRACTFLT

ACTLOSPort LEDs

TAM Blank Circuit Pack 2

TAM Blank Circuit Pack 3

TAM Blank Circuit Pack 4

TAM Blank Circuit Pack 5

Fiber Guideto route tributary and

line fibers

Handleused during circuit removal and installation

Handleused during circuit removal and installation

CLASS 1 LASERPRODUCT (IEC)CLASS I LASER

PRODUCT (CDRH)

Warning Label

TN780 Hardware Description Releas

e 1.2 UTStarcom Inc.
Page 65: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-45UTStarcom TN780

Circuit Pack Level LEDsThe DLM has 3 LEDs to indicate the circuit pack status. The significance of an illuminated LED is described in Table 2-33 on page 2-45.

Port IndicatorsThere are two LEDs: ACTIVE and LOS for the DLM circuit pack OCG port status indication. The Active LED either glows or blinks depending on the status of the circuit pack. The LOS LED indicates if the port is provisioned and if the signal is being received. The significance of an illuminated LED is described in Table 2-34 on page 2-45.

ConnectorsThe DLM has Rx and Tx interfaces to the BMM as shown in Table 2-35 on page 2-45.

Table 2-33 DLM status LED indicators

LED Indicator Color Meaning

PWR (Power) Green Indicates the presence (lit) or absence (dimmed) of power supply to the DLM circuit pack

ACT (Active) Green / Yellow Indicates the circuit pack status: Active or Standby

FLT (Fault) Red / Yellow Indicates the presence (lit) or absence (dimmed) of an alarm on the circuit pack: Critical, Major or Minor

Table 2-34 Port visual alarm indicators on DLM circuit pack

LED State Description

ACT (Active) Green / Yellow Indicates the port status: Active, Maintenance or Not provisioned

LOS Red Indicates the detection of LOS signal on the port

Table 2-35 DLM connectors

Connector Type Purpose

Line IN SC Connects from the corresponding OCG port on the BMM

Line OUT SC Connects to the corresponding OCG port on the BMM

TN780 Hardware Description Release 1.2UTStarcom Inc.

Page 66: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-46 UTStarcom TN780Page 2-46

Technical SpecificationsTable 2-36 on page 2-46 provides the electrical, mechanical, environmental specifications and reliability data for the DLM.

The optical specifications are listed in Table 2-37 on page 2-46.

Table 2-36 DLM technical specifications

Type Parameter Specification

Mechanical specifications Height 18.5” / 470mm

Width 3.53 / 90mm

Depth 11.1” / 282mm

Weight 16.5lbs approx.

Electrical specifications Power consumption 290W approx.

Input voltage range -40V DC to -60V DC

Environmental specifications Operating temperature range Normal: 5deg C to 40deg C

Short term: -5deg C to 55deg C

Storage temperature range -40deg C to 70deg C

High relative humidity 90% non-condensing

Compliance Environmental, EMI & safety NEBS Level 3, CE, IEC, ETSI, EN/IEC60950

Laser safety ANSI Class I, IEC Class 1

Table 2-37 DLM optical specifications

Type Parameter Specification

DLM-1-C1-A Frequency range OCG1 1548.915nm - 1563.455nm

Output power level -13.8dBm to -12.5dBm

DLM-3-C1-A Frequency range OCG3 1548.115nm - 1562.640nm

Output power level -13.8dBm to -12.5dBm

DLM-5-C1-A Frequency range OCG5 1531.507nm - 1545.720nm

Output power level -13.8dBm to -12.5dBm

DLM-7-C1-A Frequency range OCG7 1530.725nm - 1544.924nm

Output power level -13.8dBm to -12.5dBm

UTStarcom Inc.TN780 Hardware Description Release 1.2

Page 67: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-47UTStarcom TN780

Tributary Adapter Module 10G (TAM-2-10G)

Functional DescriptionThe Tributary Adapter Module 10G, referred to as TAM-2-10G, maps the customer client optical signals into internal electrical signals for subsequent transmission through the DLM. The TAM-2-10G circuit packs can be arbitrarily equipped in any of the sub-slots located on the DLM. TAM-2-10G circuit packs provide further sub-slots to enable the insertion of TOM-10G-SR1s and TOM-10G-IR2s (see “Tributary Optical Module 10G-SR1 (TOM-10G-SR1)” on page 2-58 and “Tributary Optical Module 10G-IR2 (TOM-10G-IR2)” on page 2-61).

TAM-2-10G supports SONET OC-192, SDH STM-64, 10GbE LAN, 10G Clear Channel, and 10GbE WAN client interfaces.

Table 2-38 TAM-2-10G product details

Product Number Product Description

TAM-2-10G-A TAM, two 10G ports

TN780 Hardware Description Release 1.2UTStarcom Inc.

Page 68: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-48 UTStarcom TN780Page 2-48

Block Diagram

Figure 2-15 TAM-2-10G functional block diagram

External Indicators and Connectors

Figure 2-16 TAM-2-10G faceplate

DTF Mapper

TAM-2-10G

Client Clock Gen

SerDes TOMINOUT

SerDes TOMINOUT

Client Clock Gen

System Clock ref

To/From DLM

From DLM

From DLM

DLM

Mid

plan

e C

onne

ctor

DTF Mapper

TAM-2-10G

Client Clock Gen

SerDes TOMINOUT

SerDes TOMINOUT

Client Clock Gen

System Clock ref

To/From DLM

From DLM

From DLM

DLM

Mid

plan

e C

onne

ctor

TOM slot 1 LEDs

TOM slot 2 LEDs

Handle

Pluggable TOM slot 1

Pluggable TOM slot 2

TAM-2-10G Circuit Pack LEDs

TN780

UTStarcom Inc. Hardware Description Release 1.2
Page 69: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-49UTStarcom TN780

Circuit Pack Level LEDsThe TAM-2-10G has 3 LEDs to indicate the circuit pack status. The significance of an illuminated LED is described in Table 2-39 on page 2-49.

TOM-10G LEDsIn addition to TAM circuit pack status indicators, the TAM-2-10G houses the TOM-10G circuit pack LEDs: ACT (Active), FLT (Fault) and LOS, one set for each TOM.The significance of an illuminated LED is described in Table 2-40 on page 2-49.

Technical SpecificationsTable 2-41 on page 2-49 provides the electrical, mechanical, environmental specifications and reliability data for the TAM-2-10G.

Table 2-39 TAM-2-10G status LED indicators

LED Indicator Color Meaning

PWR (Power) Green Indicates the presence (lit) or absence (dimmed) of power supply to the TAM-2-10G circuit pack

ACT (Active) Green / Yellow Indicates the TAM-2-10G circuit pack status: Active or Standby

FLT (Fault) Red Indicates the presence (lit) or absence (dimmed) of an alarm on the TAM-2-10G circuit pack: Critical, Major or Minor

Table 2-40 TOM-10G status indicators

LED Color Description

ACT (Active) Green / Yellow Indicates the TOM-10G-SR1 status: Active or Not provisioned

FLT (Fault) Red Indicates the presence (lit) or absence (dimmed) of a fault on the TOMLOS Red Indicates the detection of LOS signal on the TOM

Table 2-41 TAM-2-10G technical specifications

Type Parameter Specification

Mechanical specifications Height 3.65” / 93mm

Width 1.86” / 47mm

Depth 10.82” / 275mm

Weight 1.45lbs (approx)

Electrical specifications Power consumption Equipped with 2 TOMs: 27W

Input voltage 5V and 3.3V

TN780 Hardware Description Release 1.2UTStarcom Inc.

Page 70: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-50 UTStarcom TN780Page 2-50

The tributary interface details are listed in Table 2-42 on page 2-50.

Environmental specifications Operating temperature range Normal: 5deg C to 40deg C

Short term: -5deg C to 55deg C

Storage temperature range -40deg C to 70deg C

High relative humidity 90% non-condensing

Compliance Environmental, EMI & safety NEBS Level 3, CE, IEC, ETSI, EN/IEC60950

Table 2-42 TAM-2-10G tributary interface specifications

Type Parameter Specification

Tributary protocols 10 GbE LAN PHY Fully transparent

10 GbE WAN PHY Fully transparent

10G Clear Channel Fully transparent

SONET OC192 Fully transparent, B1 and J0 monitoring, Section PM

SDH STM-64 Fully transparent, B1and J0 monitoring, RS PM

Capacity Maximum capacity 20Gbps, max 2 TOM-10G-XXX per TAM-2-10G

Table 2-41 TAM-2-10G technical specifications

Type Parameter Specification

UTStarcom Inc.TN780 Hardware Description Release 1.2

Page 71: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-51UTStarcom TN780

Tributary Adapter Module 2.5G (TAM-4-2.5G)

Functional DescriptionThe Tributary Adapter Module 2.5G, referred to as TAM-4-2.5G, maps the customer client optical signals into internal electrical signals for subsequent transmission through the DLM. The TAM-4-2.5G circuit packs can be arbitrarily equipped in any of the sub-slots located on the DLM. TAM-4-2.5Gs provide further sub-slots to enable the insertion of TOM-2.5G-SR1s and TOM-2.5G-IR-1 (see “Tributary Optical Module 2.5G-SR1 (TOM-2.5G-SR1)” on page 2-64 and “Tributary Optical Module 2.5G-IR1 (TOM-2.5G-IR1)” on page 2-67).

TAM-4-2.5G supports SONET OC-48 and SDH STM-16 client interfaces.

Table 2-43 TAM-4-2.5G product details

Product Number Product Description

TAM-4-2.5G-A TAM, four 2.5G ports

TN780 Hardware Description Release 1.2UTStarcom Inc.

Page 72: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-52 UTStarcom TN780Page 2-52

Block Diagram

Figure 2-17 TAM-4-2.5G functional block diagram

External Indicators and Connectors

Figure 2-18 TAM-4-2.5G faceplate

TAM-4-2.5G

System Clock ref

QuadSerDes

To/From DLM

From DLM

DLM

Mid

plan

e C

onne

ctor

Channel 1

INOUT

Client Clock Gen

TOM SerDes

Channel 2

INOUT

Client Clock Gen

SerDes TOM

Channel 3

INOUT

Client Clock Gen

SerDes TOM

Channel 4

INOUT

Client Clock Gen

SerDes TOM

DTF Mapper

TAM-4-2.5G

System Clock ref

QuadSerDes

To/From DLM

From DLM

DLM

Mid

plan

e C

onne

ctor

Channel 1

INOUT

Client Clock Gen

TOM SerDes

Channel 1Channel 1

INOUT

Client Clock Gen

TOM SerDes

Channel 2

INOUT

Client Clock Gen

SerDes TOM

Channel 2Channel 2

INOUT

Client Clock Gen

SerDes TOM

Channel 3

INOUT

Client Clock Gen

SerDes TOM

Channel 3Channel 3

INOUT

Client Clock Gen

SerDes TOM

Channel 4

INOUT

Client Clock Gen

SerDes TOM

Channel 4Channel 4

INOUT

Client Clock Gen

SerDes TOM

DTF Mapper

TOM slot 1 LEDs

Handle

Pluggable TOM slot 1

TAM-4-2.5G Circuit Pack LEDs

Pluggable TOM slot 2

Pluggable TOM slot 3

TOM slot 2 LEDs

TOM slot 3 LEDs

TOM slot 4 LEDsPluggable TOM slot 4

TN7

UTStarcom Inc.80 Hardware Description Release 1.2
Page 73: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-53UTStarcom TN780

Circuit Pack Level LEDsThe TAM-4-2.5G has 3 LEDs to indicate the circuit pack status. The significance of an illuminated LED is described in Table 2-44 on page 2-53.

TOM-2.5G LEDsIn addition to TAM circuit pack status indicators, the TAM-4-2.5G houses the TOM-2.5G circuit pack LEDs: ACT (Active), FLT (Fault) and LOS, one set for each TOM.The significance of an illuminated LED is described in Table 2-45 on page 2-53.

Technical SpecificationsTable 2-46 on page 2-53 provides the electrical, mechanical, environmental specifications and reliability data for the TAM-4-2.5G.

Table 2-44 TAM-4-2.5G status LED indicators

LED Indicator Color Meaning

PWR (Power) Green Indicates the presence (lit) or absence (dimmed) of power supply to the TAM-4-2.5G circuit pack

ACT (Active) Green / Yellow Indicates the TAM-4-2.5G circuit pack status: Active or Standby

FLT (Fault) Red Indicates the presence (lit) or absence (dimmed) of an alarm on the TAM-4-2.5G circuit pack: Critical, Major or Minor

Table 2-45 TOM-2.5G status indicators

LED Color Description

ACT (Active) Green / Yellow Indicates the TOM status: Active, Standby or Not provisioned

FLT (Fault) Red Indicates the presence (lit) or absence (dimmed) of a fault on the TOM

LOS Red Indicates the detection of LOS signal on the TOM

Table 2-46 TAM-4-2.5G technical specifications

Type Parameter Specification

Mechanical specifications Height 3.65” / 92.7mm

Width 1.86” / 47.2mm

Depth 10.82” / 274.8mm

Weight 1.65lbs

Electrical specifications Power consumption Equipped with 4 TOMs: 35.22W

Input voltage 5V and 3.3V

TN780 Hardware Description Release 1.2UTStarcom Inc.

Page 74: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-54 UTStarcom TN780Page 2-54

The tributary interface details are listed in Table 2-47 on page 2-54.

Environmental specifications Operating temperature range Normal: 5deg C to 40deg C

Short term: -5deg C to 55deg C

Storage temperature range -40deg C to 70deg C

High relative humidity 90% non-condensing

Compliance Environmental, EMI & safety NEBS Level 3, CE, IEC, ETSI, EN/IEC60950

Table 2-47 TAM-4-2.5G tributary interface specifications

Type Parameter Specification

Tributary protocols SONET OC-48 Fully transparent, B1 and J0 monitoring, Section PM

SDH STM-16 Fully transparent, B1and J0 monitoring, RS PM

Capacity Maximum capacity 10Gbps, max 4 TOM-2.5G-XXX per TAM-4-2.5G

Table 2-46 TAM-4-2.5G technical specifications

Type Parameter Specification

UTStarcom Inc.TN780 Hardware Description Release 1.2

Page 75: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-55UTStarcom TN780

Tributary Adapter Module 1G (TAM-4-1G)

Functional DescriptionThe Tributary Adapter Module 1G, referred to as TAM-4-1G, maps the customer client ethernet signals into internal electrical signals for subsequent transmission through the DLM. The TAM-4-1G circuit packs can be arbitrarily equipped in any of the sub-slots located on the DLM. TAM-4-1Gs provide further sub-slots to enable the insertion of TOM-1G-LX’s (see “Tributary Optical Module 1G-LX (TOM-1G-LX)” on page 2-70).

TAM-4-1G supports 1GbE client interfaces. It does not support 1GbE multiplexing, rather each 1GbE client signal is mapped into a 2.5G sub-channel.

Table 2-48 TAM-4-1G product details

Product Number Product Description

TAM-4-1G-A TAM, four 1GbE ports

TN780 Hardware Description Release 1.2UTStarcom Inc.

Page 76: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-56 UTStarcom TN780Page 2-56

Block Diagram

Figure 2-19 TAM-4-1G functional block diagram

External Indicators and Connectors

Circuit Pack Level LEDsThe TAM-4-1G has 3 LEDs to indicate the circuit pack status. The significance of an illuminated LED is described in Table 2-49 on page 2-56).

Table 2-49 TAM-4-1G status LED indicators

LED Indicator Color Meaning

PWR (Power) Green Indicates the presence (lit) or absence (dimmed) of power supply to the TAM-4-1G circuit pack

ACT (Active) Green / Yellow Indicates the TAM-4-1G circuit pack status: Active or Standby

FLT (Fault) Red Indicates the presence (lit) or absence (dimmed) of an alarm on the TAM-4-1G circuit pack: Critical, Major or Minor

TAM-4-1G

DTF Mapper Quad

SerDes

System Clock ref

SerDes TOMINOUT

Client Clock Gen

SerDes TOMINOUT

Client Clock Gen

SerDes TOMINOUT

Client Clock Gen

SerDes TOMINOUT

Client Clock Gen

SerDes TOMINOUT

Client Clock Gen

SerDes TOMINOUT

Client Clock Gen

SerDes TOMINOUT

Client Clock Gen

SerDes TOMINOUT

Client Clock Gen DLM

Mid

plan

e C

onne

ctor

UTStarcom Inc.TN780 Hardware Description Release 1.2

Page 77: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-57UTStarcom TN780

TOM-1G-LX LEDsIn addition to TAM circuit pack status indicators, the TAM-4-1G houses the TOM-1G-LX circuit pack LEDs: ACT (Active), FLT (Fault) and LOS, one set for each TOM. The significance of an illuminated LED is described in Table 2-50 on page 2-57.

Technical SpecificationsTable 2-51 on page 2-57 provides the electrical, mechanical, environmental specifications and reliability data for the TAM-4-1G.

The tributary interface details are listed in Table 2-52 on page 2-57.

Table 2-50 TOM-1G-LX status indicators

LED Color Description

ACT (Active) Green / Yellow Indicates the TOM status: Active, Standby or Not provisioned

FLT (Fault) Red Indicates the presence (lit) or absence (dimmed) of a fault on the TOM

LOS Red Indicates the detection of LOS signal on the TOM

Table 2-51 TAM-4-1G technical specifications

Type Parameter Specification

Mechanical specifications Height 3.65” / 92.7mm

Width 1.86” / 47.2mm

Depth 10.82” / 274.8mm

Weight 1.65lbs

Electrical specifications Power consumption Equipped with 4 TOMs: 31.24W

Input voltage 5V and 3.3V

Environmental specifications Operating temperature range Normal: 5deg C to 40deg C

Short term: -5deg C to 55deg C

Storage temperature range -40deg C to 70deg C

High relative humidity 90% non-condensing

Compliance Environmental, EMI & safety NEBS Level 3, CE, IEC, ETSI, EN/IEC60950

Table 2-52 TAM-4-1G tributary interface specifications

Type Parameter Specification

Tributary protocols 1GbE Fully transparent

Capacity Maximum capacity 4 x 1.25Gbps, max 4 TOM-1G-LXs per TAM-4-1G

TN780 Hardware Description Release 1.2UTStarcom Inc.

Page 78: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-58 UTStarcom TN780Page 2-58

Tributary Optical Module 10G-SR1 (TOM-10G-SR1)

Functional DescriptionThe Tributary Optical Module 10G, referred to as TOM-10G-SR1, is a field-replaceable pluggable 10G XFP module. It converts the client optical signals to and from a serial electrical signal. TOM-10G-SR1s are hot-pluggable into any of the two sub-slots in the TAM-2-10Gs, and are powered through the pluggable interface.

TOM-10G-SR1 supports OC-192, STM-64, 10G Clear Channel, 10GbE WAN and 10GbE LAN client signals. The optical interface complies with SONET Telecordia SR-1 specification for the OC-192 client signal, ITU short reach specification for the STM-64 signal, 10GBASE-LR for the 10 GbE LAN client signal and 10G BASE-LW for the 10GbE WAN client signal. The TOM receiver can work with 1550nm sources.

TOM-10G-SR1 port status LEDs are located on the TAM-2-10G circuit pack (see Figure 2-16 on page 2-48).

ConnectorsThe TOM-10G-SR1 has optical interfaces to the client equipment through the ports as shown in Table 2-54 on page 2-58.

Table 2-53 TOM-10G-SR1 product details

Product Number Product Description

TOM-10G-SR1-A 10G Tributary Optical Module

Reach:

• 10GbE WAN: IEEE 802.3ae 10GBASE-LR

• 10GbE LAN: IEEE 802.3ae 10GBASE-LW

• Telcordia GR-253-CORE SR-1

• ITU-T G.957 I-64.1

Table 2-54 TOM-10G-SR1 connectors

Connector Type Purpose

Trib port IN LC Connects from the client equipment

Trib port OUT LC Connects to the client equipment

UTStarcom Inc.TN780 Hardware Description Release 1.2

Page 79: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-59UTStarcom TN780

Technical SpecificationsTable 2-55 on page 2-59 provides the electrical, mechanical, environmental specifications and reliability data for the TOM-10G-SR1.

Optical SpecificationsThe optical specifications for tributary port IN are listed in Table 2-56 on page 2-59.

Table 2-55 TOM-10G-SR1 technical specifications

Type Parameter Specification

Mechanical specifications Height 0.72” / 18mm

Width 0.34” / 9mm

Depth 3.1” / 79mm

Weight 0.1lbs (approx)

Electrical specifications Power consumption < 2.5W

Input voltage range 3.13V to 3.45V

Environmental specifications Operating temperature range -40deg C to -10deg C

Storage temperature range -40deg C to 70deg C

High relative humidity 90% non-condensing

Compliance Environmental, EMI & safety NEBS Level 3, CE, IEC, ETSI, EN/IEC60950

Laser safety ANSI Class I, IEC Class 1

Table 2-56 TOM-10G-SR1 tributary port IN optical specifications

Type Specification

Incoming fiber type Single mode

Receiver overload power 0.5dBm

Receiver sensitivity 0.5dBm to -13.4dBm

Receiver wavelength 1270nm to 1600nm

Data rate 9.95 to 10.52Gbps

TN780 Hardware Description Release 1.2UTStarcom Inc.

Page 80: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-60 UTStarcom TN780Page 2-60

The optical specifications for tributary port OUT are listed in Table 2-57 on page 2-60.

Interface SpecificationsThe tributary interface details are listed in Table 2-58 on page 2-60.

Table 2-57 TOM-10G-SR1 tributary port OUT optical specifications

Type Specification

Outgoing fiber type Single mode

Link distance 10GbE 10km spec

GR-253-CORE SR-1

ITU-T G.957 I-64.1

Transmitter output power -1dBm to -6dBm

Transmitter wavelength 1290nm to 1330nm

Data rate 9.95 to 10.52Gbps

Table 2-58 TOM-10G-SR1 tributary facilities

Type Parameter Specification

Tributary protocols 10 GbE LAN PHY Fully transparent

10 GbE WAN PHY Fully transparent

10G Clear Channel Fully transparent

SONET OC192 Fully transparent

SDH STM 64 Fully transparent

UTStarcom Inc.TN780 Hardware Description Release 1.2

Page 81: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-61UTStarcom TN780

Tributary Optical Module 10G-IR2 (TOM-10G-IR2)

Functional DescriptionThe Tributary Optical Module 10G, referred to as TOM-10G-IR2, is a field-replaceable pluggable 10G XFP module. It converts the client optical signals to and from a serial electrical signal. TOM-10G-IR2s are hot-pluggable into any of the two sub-slots in the TAM-2-10Gs, and are powered through the pluggable interface.

TOM-10G-IR2 supports OC-192, STM-64, 10G Clear Channel, 10GbE WAN and 10GbE LAN client signals. The optical interface complies with SONET Telecordia IR-2 specification for the OC-192 client signal, ITU intermediate reach specification for the STM-64 signal, 10GBASE-EW for the 10 GbE LAN client signal and 10G BASE-ER for the 10GbE WAN client signal. The TOM receiver can work with 1550nm sources.

TOM-10G-IR2 port status LEDs are located on the TAM-2-10G circuit pack (see Figure 2-16 on page 2-48).

ConnectorsThe TOM-10G-IR2 has the optical interfaces to the client equipment through the ports as shown in Table 2-60 on page 2-61.

Table 2-59 TOM-10G-IR2 product details

Product Number Product Description

TOM-10G-IR2-A 10G Tributary Optical Module

Reach:

• 10GbE WAN: IEEE 802.3ae 10GBASE-ER

• 10GbE LAN: IEEE 802.3ae 10GBASE-EW

• Telcordia GR-253-CORE IR-2

• ITU-T G.957 S-64.2

Table 2-60 TOM-10G-IR2 connectors

Connector Type Purpose

Trib port IN LC Connects from the client equipment

Trib port OUT LC Connects to the client equipment

TN780 Hardware Description Release 1.2UTStarcom Inc.

Page 82: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-62 UTStarcom TN780Page 2-62

Technical SpecificationsTable 2-61 on page 2-62 provides the electrical, mechanical, environmental specifications and reliability data for the TOM-10G-IR2.

Optical SpecificationsThe optical specifications for tributary port IN are listed in Table 2-62 on page 2-62.

Table 2-61 TOM-10G-IR2 technical specifications

Type Parameter Specification

Mechanical specifications Height 0.72” / 18mm

Width 0.34” / 9mm

Depth 3.1” / 79mm

Weight 0.1lbs (approx)

Electrical specifications Power consumption < 3.5W

Input voltage range 3.135V to 3.465V

Environmental specifications Operating temperature range 5 deg C to 40 deg C

Storage temperature range -5 deg C to 55 deg C

High relative humidity 85% non-condensing

Compliance Environmental, EMI & safety NEBS Level 3, CE, IEC, ETSI

Laser safety ANSI Class I, IEC Class 1

Table 2-62 TOM-10G-IR2 tributary port IN optical specifications

Type Specification

Incoming fiber type Single mode

Receiver overload power 0.5dBm

Receiver sensitivity -14dBm to -1dBm

Receiver wavelength 1260nm to 1565nm

Data rate 9.95 to 10.75Gbps

UTStarcom Inc.TN780 Hardware Description Release 1.2

Page 83: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-63UTStarcom TN780

The optical specifications for tributary port OUT are listed in Table 2-63 on page 2-63.

Table 2-63 TOM-10G-IR2 tributary port OUT optical specifications

Interface SpecificationsThe tributary interface details are listed in Table 2-64 on page 2-63.

Type Specification

Outgoing fiber type Single mode

Link distance • 10GbE WAN: IEEE 802.3ae 10GBASE-ER

• 10GbE LAN: IEEE 802.3ae 10GBASE-EW

• Telcordia GR-253-CORE IR-2

• ITU-T G.957 S-64.2

Transmitter output power -1dBm to 2-6dBm

Transmitter wavelength 1530nm to 1565nm

Data rate 9.95 to 10.75Gbps

Table 2-64 TOM-10G-IR2 tributary facilities

Type Parameter Specification

Tributary protocols 10 GbE LAN PHY Fully transparent

10 GbE WAN PHY Fully transparent

10G Clear Channel Fully transparent

SONET OC192 Fully transparent

SDH STM 64 Fully transparent

TN780 Hardware Description Release 1.2UTStarcom Inc.

Page 84: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-64 UTStarcom TN780Page 2-64

Tributary Optical Module 2.5G-SR1 (TOM-2.5G-SR1)

Functional DescriptionThe Tributary Optical Module 2.5G, referred to as TOM-2.5G-SR1, is a field-replaceable pluggable 2.5G SFP module. It converts the client optical signals to and from a serial electrical signal. The TOM-2.5G-SR1s are hot-pluggable into any of the four sub-slots in the TAM-4-2.5Gs, and are powered through the pluggable interface.

TOM-2.5G-SR1 supports OC-48 and STM-16 client signals. The optical interface complies with SONET Telecordia SR-1 specification for the OC-48 client signal, ITU short reach specification for the STM-16 signal. The TOM receiver can work with 1550nm sources.

TOM-2.5G-SR1 port status LEDs are located on the TAM-4-2.5G circuit pack (see Figure 2-18 on page 2-52).

ConnectorsThe TOM-2.5G-SR1 has the optical interfaces to the client equipment through the ports as shown in Table 2-66 on page 2-64.

Table 2-65 TOM-2.5G-SR1 product details

Product Number Product Description

TOM-2.5G-SR1-A 2.5G Tributary Optical Module

Reach:

• Telcordia GR-253-CORE OC-48 SR (12km)

• ITU-T G.957 STM-16 I-16 (2km)

Table 2-66 TOM-2.5G-SR1 connectors

Connector Type Purpose

Trib port IN LC Connects from the client equipment

Trib port OUT LC Connects to the client equipment

UTStarcom Inc.TN780 Hardware Description Release 1.2

Page 85: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-65UTStarcom TN780

Technical SpecificationsTable 2-67 on page 2-65 provides the electrical, mechanical, environmental specifications and reliability data for the TOM-2.5G-SR1.

Optical SpecificationsThe optical specifications for tributary port IN are listed in Table 2-68 on page 2-65.

Table 2-67 TOM-2.5G-SR1 technical specifications

Type Parameter Specification

Mechanical specifications Height 0.52” / 13.27mm

Width 0.33” / 8.5mm

Depth 2.23” / 56.6mm

Weight 0.1lbs (approx)

Electrical specifications Power consumption <1.04W

Input voltage range 3.135V to 3.465V

Environmental specifications Operating temperature range -10deg C to 85deg C

Storage temperature range -40deg C to 70deg C

High relative humidity 90% non-condensing

Compliance Environmental, EMI & safety NEBS Level 3, CE, IEC, ETSI, EN/IEC60950

Laser safety ANSI Class I, IEC Class 1

Table 2-68 TOM-2.5G-SR1 tributary port IN optical specifications

Type Specification

Incoming fiber type 9/125micrometer, single mode

Receiver overload power 0dBm

Receiver sensitivity -3dBm to -18dBm

Receiver wavelength 1266nm to 1360nm

Data rate 2.488Gbps

TN780 Hardware Description Release 1.2UTStarcom Inc.

Page 86: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-66 UTStarcom TN780Page 2-66

The optical specifications for tributary port OUT are listed in Table 2-69 on page 2-66.

Interface SpecificationsThe tributary interface details are listed in Table 2-70 on page 2-66.

Table 2-69 TOM-2.5G-SR1 tributary port OUT optical specifications

Type Specification

Outgoing fiber type 9/125 Single mode

Link distance GR-253-CORE SR-1 (12km)

ITU-T G.957 I-16 (2km)

Transmitter output power -10dBm to -3dBm

Transmitter wavelength 1266nm to 1360nm

Data rate 2.488Gbps

Table 2-70 TOM-2.5G-SR1 tributary facilities

Type Parameter Specification

Tributary protocols SONET OC-48 Fully transparent

SDH STM-16 Fully transparent

UTStarcom Inc.TN780 Hardware Description Release 1.2

Page 87: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-67UTStarcom TN780

Tributary Optical Module 2.5G-IR1 (TOM-2.5G-IR1)

Functional DescriptionThe Tributary Optical Module 2.5G, referred to as TOM-2.5G-IR1, is a field-replaceable pluggable 2.5G SFP module. It converts the client optical signals to and from a serial electrical signal. The TOM-2.5G-IR1s are hot-pluggable into any of the four sub-slots in the TAM-4-2.5Gs, and are powered through the pluggable interface.

TOM-2.5G-IR1 supports OC-48 and STM-16 client signals. The optical interface complies with SONET Telecordia IR-1 specification for the OC-48 client signal, ITU intermediate specification for the STM-16 signal. The TOM receiver can work with 1550nm sources.

TOM-2.5G-IR1 port status LEDs are located on the TAM-4-2.5G circuit pack (see Figure 2-18 on page 2-52).

ConnectorsThe TOM-2.5G-IR1 has the optical interfaces to the client equipment through the ports as shown in Table 2-72 on page 2-67.

Table 2-71 TOM-2.5G-IR1 product details

Product Number Product Description

TOM-2.5G-IR1-A 2.5G Tributary Optical Module

Reach:

• Telcordia GR-253-CORE OC-48 IR-1

• ITU-T G.957 S-16.1

Table 2-72 TOM-2.5G-IR1 connectors

Connector Type Purpose

Trib port IN LC Connects from the client equipment

Trib port OUT LC Connects to the client equipment

TN780 Hardware Description Release 1.2UTStarcom Inc.

Page 88: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-68 UTStarcom TN780Page 2-68

Technical SpecificationsTable 2-73 on page 2-68 provides the electrical, mechanical, environmental specifications and reliability data for the TOM-2.5G-IR1.

Optical SpecificationsThe optical specifications for tributary port IN are listed in Table 2-74 on page 2-68.

Table 2-73 TOM-2.5G-IR1 technical specifications

Type Parameter Specification

Mechanical specifications Height 0.52” / 13.27mm

Width 0.33” / 8.5mm

Depth 2.23” / 56.6mm

Weight 0.1lbs (approx)

Electrical specifications Power consumption <1W

Input voltage range 3.135V to 3.465V

Environmental specifications Operating temperature range 5deg C to 40deg C

Storage temperature range -5deg C to 55deg C

High relative humidity 90% non-condensing

Compliance Environmental, EMI & safety NEBS Level 3, CE, IEC, ETSI

Laser safety ANSI Class I, IEC Class 1

Table 2-74 TOM-2.5G-IR1 tributary port IN optical specifications

Type Specification

Incoming fiber type 9/125micrometer, single mode

Receiver overload power 0dBm

Receiver sensitivity 0dBm to -18dBm

Receiver wavelength 1266nm to 1360nm

Data rate 2.5Gbps

UTStarcom Inc.TN780 Hardware Description Release 1.2

Page 89: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-69UTStarcom TN780

The optical specifications for tributary port OUT are listed in Table 2-75 on page 2-69.

Interface SpecificationsThe tributary interface details are listed in Table 2-76 on page 2-69.

Table 2-75 TOM-2.5G-IR1 tributary port OUT optical specifications

Type Specification

Outgoing fiber type 9/125 Single mode

Link distance GR-253-CORE IR-1

ITU-T G.957 S-16.1

Transmitter output power -5dBm to -30dBm

Transmitter wavelength 1260nm to 1360nm

Data rate 2.5Gbps

Table 2-76 TOM-2.5G-IR1 tributary facilities

Type Parameter Specification

Tributary protocols SONET OC-48 Fully transparent

SDH STM-16 Fully transparent

TN780 Hardware Description Release 1.2UTStarcom Inc.

Page 90: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-70 UTStarcom TN780Page 2-70

Tributary Optical Module 1G-LX (TOM-1G-LX)

Functional DescriptionThe Tributary Optical Module 1G, referred to as TOM-1G-LX, is a field-replaceable pluggable 1G SFP module. It converts the client optical signals to and from a serial electrical signal. The TOM-1G-LXs are hot-pluggable into any of the four sub-slots in the TAM-4-1Gs, and are powered through the pluggable interface.

TOM-1G-LX supports 1GbE client signals. The optical interface complies with IEEE802.3z 10000Base-LX client signals. The TOM receiver can work with 1310nm sources.

TOM-1G-LX port status LEDs are located on the TAM-4-1G circuit pack.

ConnectorsThe TOM-1G-LX has the optical interfaces to the client equipment through the ports as shown in Table 2-78 on page 2-70.

Table 2-77 TOM-1G-LX product details

Product Number Product Description

TOM-1G-LX-A 1G Tributary Optical Module

Reach:

• 1.25 GbE: IEEE 802.3z 1000Base-LX (5km)

Table 2-78 TOM-1G-LX connectors

Connector Type Purpose

Trib port IN LC Connects from the client equipment

Trib port OUT LC Connects to the client equipment

UTStarcom Inc.TN780 Hardware Description Release 1.2

Page 91: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-71UTStarcom TN780

Technical SpecificationsTable 2-79 on page 2-71 provides the electrical, mechanical, environmental specifications and reliability data for the TOM-1G-LX.

Optical SpecificationsThe optical specifications for tributary port IN are listed in Table 2-80 on page 2-71.

Table 2-79 TOM-1G-LX technical specifications

Type Parameter Specification

Mechanical specifications Height 0.52” / 13.7mm

Width 0.33” / 8.5mm

Depth 2.23” / 56.6mm

Weight 0.1lbs (approx)

Electrical specifications Power consumption <1W

Input voltage range 2.97V to 3.63V

Environmental specifications Operating temperature range 5deg C to 40deg C

Storage temperature range -5deg C to 55deg C

High relative humidity 85% non-condensing

Compliance Environmental, EMI & safety NEBS Level 3, CE, IEC, ETSI

Laser safety ANSI Class I, CDRH 21, CFR1040, Laser Notice 50, IEC Class 1

Table 2-80 TOM-1G-LX tributary port IN optical specifications

Type Specification

Incoming fiber type 9um, single mode

Receiver overload power -3dBm

Receiver sensitivity -3dBm to -19dBm

Receiver wavelength 1260nm to 1580nm

Data rate 1.25Gbps

TN780 Hardware Description Release 1.2UTStarcom Inc.

Page 92: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-72 UTStarcom TN780Page 2-72

The optical specifications for tributary port OUT are listed in Table 2-81 on page 2-72.

Interface SpecificationsThe tributary interface details are listed in Table 2-82 on page 2-72.

Table 2-81 TOM-1G-LX tributary port OUT optical specifications

Type Specification

Outgoing fiber type 9um, Single mode

Link distance IEEE 802.3z 1000Base-LX (5km)

Transmitter output power -3dBm to -11dBm

Transmitter wavelength 1285nm to 1350nm

Data rate 1.25Gbps

Table 2-82 TOM-1G-LX tributary facilities

Type Parameter Specification

Tributary protocols 1 GbE Fully transparent

UTStarcom Inc.TN780 Hardware Description Release 1.2

Page 93: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-73UTStarcom TN780

Blank Circuit PacksWhenever a circuit pack is removed, the blank space must be occupied by the corresponding blank circuit pack. Blank circuit packs serve three important functions:

Prevents exposure to hazardous voltage and currents inside the chassis

Contains any electromagnetic interference (EMI) that might damage other equipment

Directs the flow of cooling air through the chassis.

Table 2-83 on page 2-73 lists the corresponding blank circuit packs.

Table 2-83 DTC blank circuit packs

Product Number Product Description

MCM-BLANK Management Control Module (MCM) blank

BMM-BLANK Band Mux Module (BMM) blank

DLM-BLANK Digital Line Module (DLM) blank

TAM-BLANK Tributary Adaptor Module (TAM) blank

TN780 Hardware Description Release 1.2UTStarcom Inc.

Page 94: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 2-74 UTStarcom TN780Page 2-74

UTStarcom Inc.TN780 Hardware Description Release 1.2

Page 95: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

CHAPTER 3

UTStarcom Optical Line Amplifier

The UTStarcom Optical Line Amplifier is a bi-directional in-line amplifier used to extend the optical reach between TN780s. Refer to the UTStarcom TN780 System Description document for a detailed functional description and application of the Optical Line Amplifier.

The Optical Line Amplifier is comprised of an Optical Transport Chassis (OTC) and an optional Dispersion Management Chassis (DMC) for dispersion compensation. Refer to “UTStarcom Dispersion Management Chassis” on page 4-1 for details on the DMC.

This chapter provides a description of the hardware found in the OTC. This chapter includes functional description of the hardware, block diagram of the internal signal flow (wherever applicable), and technical specifications. This chapter includes the following sections:

“OTC Overview” on page 3-2

“OTC Compliancy” on page 3-3

“OTC” on page 3-4

“Optical Management Module (OMM)” on page 3-20

“Optical Amplifier Module (OAM)” on page 3-24

“Blank Circuit Packs” on page 3-30

For Optical Line Amplifier installation procedures, refer to the UTStarcom TN780 Site Preparation and Hardware Installation Guide. For Optical Line Amplifier turn-up and test procedures refer to the UTStarcom TN780 Turn-up and Test Guide.

Refer to UTStarcom TN780 Maintenance and Troubleshooting Guide for the description of module Light Emitting Diodes (LED) status indicators.

TN780 Hardware Description Release 1.2UTStarcom Inc.

Page 96: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 3-2 UTStarcom Optical Line AmplifierPage 3-2

OTC OverviewTable 3-1 on page 3-2 gives a list of OTC components and field replaceable circuit packs.

Front ViewA front view of the OTC with chassis components and circuit packs is shown in Figure 3-1 on page 3-2.

Figure 3-1 OTC front view

Table 3-1 List of OTC hardware equipment

Equipment Type Name Short Description

OTC components Rack Mounting Ears See page 3-6Power Entry Modules See page 3-6I/O/Alarm Panel See page 3-9Fan Tray See page 3-17Air Filter See page 3-18

Circuit Packs Optical Management Module (OMM) See page 3-20Optical Amplifier Module (OAM) See page 3-24

Air Filter

Fiber Guide

Fan Tray A Fan Tray B

Air Inlet

PEM A

OWMCable Guide

PEM B

Managementfor IAP IAP

Managementfor IAP

OAMs

OMMs

UTStarcom Inc.TN780 Hardware Description Release 1.2

Page 97: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 3-3UTStarcom Optical Line Amplifier

OTC CompliancyThe OTC complies with many Industry standard specifications as described in Table 3-2 on page 3-3.

Table 3-2 OTC hardware compliancy

Category Approval Agency / Requirement

Safety Certifications • UL 60950: Safety of Information Technology Equipment

• CAN/CSA C22.2 No. 60950: Safety of Information Technology Equipment

• EN 60950 (Low Voltage Directive): Safety of Information Technology Equip-ment including electrical business equipment

• IEC 60950: Safety of Information Technology Equipment, including electrical business equipment

• TS001: Safety requirements for customer equipment

• AS/NZS 60950: Approval & Test specification -- Safety of information tech-nology equipment including electrical business equipment

NEBS/ETSI Compliancy • GR-1089-CORE: Electromagnetic Compatibility and Electrical Safety - Generic requirement for Network Telecommunications Equipment

• NEBS

• ETS 300 386

• GR-63-CORE: Network Equipment Building Systems -- Physical Protection

• ETS 300 019-2-1

• ETS 300 019-2-2

• ETS 300-019-2-3

• ETS 300 753

General Compliancy • ETSI ETS 300 119-4

• Telecordia GR-63-CORE

• Telecordia GR-78-CORE

• Telecordia GR-253-CORE

• ANSI T1.315-1994

• ANSI T1.304 1989

EMC Emissions • EN55022 Class A

EMC Immunity • EN61000-4-2,3,4,5,6

Laser Safety • EN60825 Series: Safety of Laser Products

• FDA21 CFR 1040: Performance Standard of Light Emitting Products

TN780 Hardware Description Release 1.2UTStarcom Inc.

Page 98: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 3-4 UTStarcom Optical Line AmplifierPage 3-4

OTC

Functional DescriptionThe OTC supports the following functions:

Each OTC performs bi-directional optical amplification of the signal

Performs optical multiplexing and demultiplexing of the C band

Implements forty 10Gbps channels in the C-band channel plan

Architected to support forty 10Gbps channels in the L-band channel plan and eighty 10Gbps chan-nels in the C-band channel plan supporting 1.2 Tbps of capacity per fiber in future releases

The OTC can be installed in a 23” rack or 600mmx600mm ETSI rack

The OTC contains two electrical ground points. Two sets of two 1/4-20 press-nuts are located on the chassis at the rear bottom position. The rack mounting ears are the second grounding point.

The OTC contains an I/O and Alarm Panel (IAP) which provides front-accessible interfaces, but does not contain any field replaceable modules. Refer to Figure 3-1 on page 3-2 for the illustration of the OTC components.

Rack mounting ears (see “Rack Mounting Ears” on page 3-6)

Two power entry modules (see “Power Entry Module” on page 3-6)

One I/O/Alarm panel (see “I/O / Alarm Panel (IAP)” on page 3-9)

Two fan trays (see “Fan Tray” on page 3-17)

One air filter (see “Air Filter” on page 3-18)

One card cage (see “Card Cage” on page 3-19)

Table 3-3 OTC product details

Product Number Product Description

OTC-ANSI-A Optical Transport Chassis ANSI

OTC-ETSI-A Optical Transport Chassis ETSI

UTStarcom Inc.TN780 Hardware Description Release 1.2

Page 99: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 3-5UTStarcom Optical Line Amplifier

Technical SpecificationsTable 3-4 on page 3-5 provides the mechanical, electrical, environmental specifications and reliability data for the OTC.

Table 3-4 OTC technical specifications

Type Parameter Specification

Mechanical specifications Height 12.2” / 310mm

Width 19.50” / 500mm

Depth 9.3” / 236mm

Weight 49.5lbs

Electrical specifications Power consumption 350W maximum

Input voltage range -40V DC to -60V DC

Environmental specifications Operating temperature range Normal: 5deg C - 40deg C

Short term: -5deg C to 55deg C

Storage temperature range -40deg C to 70deg C

High relative humidity 90% non-condensing

Compliance Environmental, EMI & safety NEBS Level 3, CE, IEC, ETSI, EN/IEC60950

TN780 Hardware Description Release 1.2UTStarcom Inc.

Page 100: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 3-6 UTStarcom Optical Line AmplifierPage 3-6

Figure 3-2 OTC dimensions

Rack Mounting EarsEach OTC includes flush rack mounting ears as an integral part of the chassis. The rack mounting ears are utilized to flush mount the chassis in a 23” rack or 600mmx600mm ETSI rack. Separate forward mount ears are also provided additionally to allow the chassis to be flush mount, 5” and 6” forward from the front of the 23” rack.

Power Entry ModuleThe top position of the OTC accommodates two Power Entry Modules (PEM), PEM A and PEM B for redundant power feeds. The PEM is a pluggable module. The power feeds into the PEM from each side of the chassis. See Figure 3-3 on page 3-7 for the display details.

12.20”

20.275” in ETSI Mounting

22.312” 23 in rack mounting

Front View

9.298”

21.060”

22.980”

Top View

19.50”

1.29”

11.85”

Front Door

0.40” Ground

TN780 Hardware Description Release 1.2

UTStarcom Inc.
Page 101: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 3-7UTStarcom Optical Line Amplifier

External Indicators

Figure 3-3 PEM faceplate

Power LEDsThe PEMs located on top of the chassis have two status LEDs: POWER INPUT and POWER FAULT. The significance of a lit LED is described in Table 3-5 on page 3-7. There are two PEMs per OTC for redundancy.

ConnectorsEach PEM is provided with a terminal block with two wire clamps. One wire clamp is for connection to -48V Power and the second to its Return. A plastic safety cover is provided to prevent inadvertent contact with the terminals once installed.

Table 3-5 Visual alarm indicators on power entry module

LED Color Description

POWER INPUT

Green Indicates the presence (lit) or absence (dimmed) of power supply to the PEM

POWER FAULT

Red Indicates whether the power output from the PEM is within the specification (lit) or not (dimmed)

Power Input LED Power Fault LED

Return Lead-48 V Supply

TN780 Hardware Description Release 1.2UTStarcom Inc.

Page 102: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 3-8 UTStarcom Optical Line AmplifierPage 3-8

Technical SpecificationsTable 3-6 on page 3-8 provides the mechanical, electrical, environmental specifications and reliability data for the PEM.

Power Distribution ArchitecturePEM A and PEM B, which provide redundant power supply to the OTC, distributes power to the power connectors of the backplane. The backplane feeds the power supply from each PEM to the circuit packs (see Figure 3-4 on page 3-9).

Table 3-6 PEM technical specifications

Type Parameter Specification

Mechanical specifications Height 1.5” / 38mm

Width 2.2” / 56mm

Depth 8.53” / 217mm

Weight 0.5lbs

Electrical specifications Power consumption 20W each

Input voltage range -40V DC to -60V DC

Environmental specifications Operating temperature range Normal: 5 - 40deg C

Short term: -5deg C to 55deg C

Storage temperature range -40deg C to 70deg C

High relative humidity 90% non-condensing

Compliance Environmental, EMI & safety NEBS Level 3, CE, IEC, ETSI, EN/IEC60950

UTStarcom Inc.TN780 Hardware Description Release 1.2

Page 103: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 3-9UTStarcom Optical Line Amplifier

Figure 3-4 Power distribution diagram

The OTC hardware modules combine the power feed by diode-ORing. The -48V inputs are individually fused on the circuit packs, the IAP, and fan trays to protect it from overcurrent conditions. The fuse is not field replaceable. The status of each fuse is monitored before the ORing diodes. A diode and a transorb are provided to protect against reverse polarity and transient overvoltage conditions.

I/O / Alarm Panel (IAP)The IAP is located at the top of the OTC. The IAP houses the management and operations interfaces and environmental alarm input and output contacts as shown in Figure 3-5 on page 3-10 and enumerated below:

Two 10/100Mb Data Communications Network (DCN) RJ-45 interfaces, referred to as DCN

Two 10Mb Administrative Inter-LAN RJ-45 interfaces, referred to as AUX interface for providing datawire services

Chassis level alarm LED (Power, Critical, Major, Minor)

Four inter-chassis interconnect RJ-45 interfaces referred to as Nodal Control and Timing, for multi-chassis configuration

One Lamp Test button

One Alarm CutOff (ACO) button

One ACO LED

Environmental alarm contacts through wire-wrap pins

Craft RS232 Modem port

PEM B

-48V A

-48V B

OMM - slots 1A & 1B

PEM A

OAM - slots 2 & 3

Fan Trays A & B

I/O and Alarm Panel

TN780 Hardware Description Release 1.2UTStarcom Inc.

Page 104: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 3-10 UTStarcom Optical Line AmplifierPage 3-10

External Indicators

Figure 3-5 OTC I/O / Alarm panel front view

Chassis-Level Alarm LEDsThe IAP has five chassis level alarm LEDs. Each chassis has an ACO button on the alarm panel which controls the reporting of audible alarms. The significance of a lit LED is described in Table 3-7 on page 3-10.

Chassis-Level Audio IndicatorsThe IAP has output alarm contacts for CRITICAL, MAJOR and MINOR audio alarms. Audio alert is triggered when an alarm is raised on the chassis.

Table 3-7 Visual alarm indicators - chassis level

LED Color Description

POWER Green Indicates the presence (lit) or absence (dimmed) of power supply within the specified operating range to the chassis

CRITICAL Red Indicates the presence (lit) or absence (dimmed) of Critical alarms in the chassis

MAJOR Red Indicates the presence (lit) or absence (dimmed) of Major alarms in the chas-sis

MINOR Yellow Indicates the presence (lit) or absence (dimmed) of Minor alarms in the chas-sis

ACO Yellow Indicates the alarm cut-off state

ControlTimingControlTiming

RJ-45 interfaces for Inter-chassis connection

Alarms LEDs

RS 232 Modem port

Ethernet interfaces

Wire wrap pins for alarm inputs

Wire wrap pins for alarm outputs

TN780 Hardware Description Release 1.2

UTStarcom Inc.
Page 105: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 3-11UTStarcom Optical Line Amplifier

Alarm Cutoff IndicatorsThe IAP contains one ACO button and an ACO LED. The ACO feature allows muting of the audible alarms. When the ACO button is pressed, all current critical, major and minor audio alarms are muted and the ACO LED is lit. See Table 3-8 on page 3-11, for the description of the alarm state and the ACO LED state.

Lamp TestThe IAP contains a lamp test button for testing the LEDs. When the lamp test button is pressed, all LEDs on the IAP and the circuit packs on the chassis are lit for 10 seconds.

ConnectorsThe panel has external connectors for input and output dry alarm contacts. They are 0.045sq. inch pins accessible from the front of IAP for easy interconnection. These contacts are used for integration with existing environmental alarm systems. See Table 3-9 on page 3-11 for connectors on IAP.

Table 3-8 Audio alarm conditions - chassis level

Condition ACO LED State Audio Alarm

There are no alarms on the chassis OFF Not present

An alarm is raised on the chassis OFF Present

ACO button is pressed ON Muted

An alarm is cleared OFF Not present

Table 3-9 OTC connectors

Connector Type Purpose

ALARM INPUTS 0.045sq. inch wire wrap pins

Environmental alarm inputs

ALARM OUTPUTS 0.045sq. inch wire wrap pins

Environmental alarm output and office alarm output contacts

DCN A, DCN B 10/100Base-Tx Auto-MDIX RJ45

Two connectors with redundancy for remote manage-ment through DCN

AUX A, AUX B 10/100Base-Tx Auto-MDIX RJ45

Two connectors with redundancy for datawire service to carry customer management traffic

NODAL CONTROL AND TIMING

100Base-Tx Auto-MDIX RJ45

Four connectors for Inter-chassis communication for uplink and downlink with A and B connectors for redun-dancy

CRAFT DTE 57600 RS232 DTE DB9 Male

For remote management through external modem

TN780 Hardware Description Release 1.2UTStarcom Inc.

Page 106: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 3-12 UTStarcom Optical Line AmplifierPage 3-12

Note: NCT ports are used for multi-chassis interconnection.

Technical SpecificationsThe environmental alarm contacts have electrical ratings as described in Table 3-10 on page 3-12.

Alarm Input Contact Pin AssignmentsThe contact specification for alarm input are described in Table 3-11 on page 3-12. One alarm contact is predefined. There are 16 user-defined alarm contacts useful for generation of customized alarms which can be triggered remotely through network management.

Table 3-10 Alarm relay contact specifications

Parameter Value

Maximum voltage 250V AC, 220V DC

Maximum current 2A

Rated load 0.5A @ 125V AC, 2A @ 30V DC

Wire size 24AWG min.

Maximum surge voltage between contact and coil 2,500V

Table 3-11 Alarm input contact pin assignments

Pin Description Function

Row Column

1 A Alarm Input Contact 1 User defined

1 B Alarm Input Contact 1 User defined

1 C Alarm Input Contact 5 User defined

1 D Alarm Input Contact 5 User defined

1 E Alarm Input Contact 9 User defined

1 F Alarm Input Contact 9 User defined

1 G Alarm Input Contact 13 User defined

1 H Alarm Input Contact 13 User defined

1 I Alarm Input Contact 17 Not Supported

1 J Alarm Input Contact 17 Not Supported

2 A Alarm Input Contact 2 User defined

2 B Alarm Input Contact 2 User defined

2 C Alarm Input Contact 6 User defined

UTStarcom Inc.TN780 Hardware Description Release 1.2

Page 107: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 3-13UTStarcom Optical Line Amplifier

Note: In Release 1.2 input contacts 17, 18, and 19 are not supported on the OTC.

2 D Alarm Input Contact 6 User defined

2 E Alarm Input Contact 10 User defined

2 F Alarm Input Contact 10 User defined

2 G Alarm Input Contact 14 User defined

2 H Alarm Input Contact 14 User defined

2 I Alarm Input Contact 18 Not Supported

2 J Alarm Input Contact 18 Not Supported

3 A Alarm Input Contact 3 User defined

3 B Alarm Input Contact 3 User defined

3 C Alarm Input Contact 7 User defined

3 D Alarm Input Contact 7 User defined

3 E Alarm Input Contact 11 User defined

3 F Alarm Input Contact 11 User defined

3 G Alarm Input Contact 15 User defined

3 H Alarm Input Contact 15 User defined

3 I Alarm Input Contact 19 Not Supported

3 J Alarm Input Contact 19 Not Supported

4 A Alarm Input Contact 4 User defined

4 B Alarm Input Contact 4 User defined

4 C Alarm Input Contact 8 User defined

4 D Alarm Input Contact 8 User defined

4 E Alarm Input Contact 12 User defined

4 F Alarm Input Contact 12 User defined

4 G Alarm Input Contact 16 User defined

4 H Alarm Input Contact 16 User defined

4 I Reserved for Alarm cut-off Predefined

4 J Reserved for Alarm cut-off Predefined

Table 3-11 Alarm input contact pin assignments

Pin Description Function

TN780 Hardware Description Release 1.2UTStarcom Inc.

Page 108: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 3-14 UTStarcom Optical Line AmplifierPage 3-14

Alarm Output Contact Pin AssignmentsTen alarm contacts are pre-defined in the system and the remaining ten contacts can be customized by the user to monitor the environmental alarms. The contact specification for alarm outputs are described in Table 3-12 on page 3-14.

Table 3-12 Alarm output contact pin assignments

Pin Description Function

Row Column

1 K Alarm Output Contact 1,

RETURN

User defined

1 L Alarm Output Contact 1,

NORMALLY OPEN

User defined

1 M Alarm Output Contact 1,

NORMALLY CLOSED

User defined

1 N Alarm Output Contact 5,

RETURN

User defined

1 O Alarm Output Contact 5,

NORMALLY OPEN

User defined

1 P Alarm Output Contact 5,

NORMALLY CLOSED

User defined

1 Q Alarm Output Contact 9,

RETURN

User defined

1 R Alarm Output Contact 9,

NORMALLY OPEN

User defined

1 S Alarm Output Contact 9,

NORMALLY CLOSED

User defined

1 T Minor Audio Alarm,

RETURN

Predefined

1 U Minor Audio Alarm,

NORMALLY OPEN

Predefined

1 V Minor Audio Alarm,

NORMALLY CLOSED

Predefined

1 W Power Fault Bay Alarm,

RETURN

Predefined

1 X Power Fault Bay Alarm,

NORMALLY OPENa

Predefined

UTStarcom Inc.TN780 Hardware Description Release 1.2

Page 109: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 3-15UTStarcom Optical Line Amplifier

1 Y Power Fault Bay Alarm,

NORMALLY CLOSEDa

Predefined

2 K Alarm Output Contact 2,

RETURN

User defined

2 L Alarm Output Contact 2,

NORMALLY OPEN

User defined

2 M Alarm Output Contact 2,

NORMALLY CLOSED

User defined

2 N Alarm Output Contact 6,

RETURN

User defined

2 O Alarm Output Contact 6,

NORMALLY OPEN

User defined

2 P Alarm Output Contact 6,

NORMALLY CLOSED

User defined

2 Q Alarm Output Contact 10,

RETURN

User defined

2 R Alarm Output Contact 10,

NORMALLY OPEN

User defined

2 S Alarm Output Contact 10,

NORMALLY CLOSED

User defined

2 T Critical Visual Alarm,

RETURN

Predefined

2 U Critical Visual Alarm,

NORMALLY OPEN

Predefined

2 V Critical Visual Alarm,

NORMALLY CLOSED

Predefined

2 W Critical Bay Alarm,

RETURN

Predefined

2 X Critical Bay Alarm,

NORMALLY OPEN

Predefined

2 Y Critical Bay Alarm,

NORMALLY CLOSED

Predefined

3 K Alarm Output Contact 3,

RETURN

User defined

Table 3-12 Alarm output contact pin assignments

Pin Description Function

TN780 Hardware Description Release 1.2UTStarcom Inc.

Page 110: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 3-16 UTStarcom Optical Line AmplifierPage 3-16

3 L Alarm Output Contact 3,

NORMALLY OPEN

User defined

3 M Alarm Output Contact 3,

NORMALLY CLOSED

User defined

3 N Alarm Output Contact 7,

RETURN

User defined

3 O Alarm Output Contact 7,

NORMALLY OPEN

User defined

3 P Alarm Output Contact 7,

NORMALLY CLOSED

User defined

3 Q Critical Audio Alarm,

RETURN

Predefined

3 R Critical Audio Alarm,

NORMALLY OPEN

Predefined

3 S Critical Audio Alarm,

NORMALLY CLOSED

Predefined

3 T Major Visual Alarm,

RETURN

Predefined

3 U Major Visual Alarm,

NORMALLY OPEN

Predefined

3 V Major Visual Alarm,

NORMALLY CLOSED

Predefined

3 W Major Bay Alarm,

RETURN

Predefined

3 X Major Bay Alarm,

NORMALLY OPEN

Predefined

3 Y Major Bay Alarm,

NORMALLY CLOSED

Predefined

4 K Alarm Output Contact 4,

RETURN

User defined

4 L Alarm Output Contact 4,

NORMALLY OPEN

User defined

4 M Alarm Output Contact 4,

NORMALLY CLOSED

User defined

Table 3-12 Alarm output contact pin assignments

Pin Description Function

UTStarcom Inc.TN780 Hardware Description Release 1.2

Page 111: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 3-17UTStarcom Optical Line Amplifier

Fan TrayThe OTC contains two removable fan trays, one on the left and one on the right of the chassis. Each fan tray consists of an individually controlled fan. The thermal system employs a push-pull approach to move air through the system, with air flow entering from the front of the chassis near the right side and exiting from the rear of the chassis near the left side (or from the front and rear for ETSI). The fan on the left side of the chassis is referred to as Fan Tray A, and the fan on the right side is referred to as Fan Tray B, when looking at the front of the OTC.

4 N Alarm Output Contact 8,

RETURN

User defined

4 O Alarm Output Contact 8,

NORMALLY OPEN

User defined

4 P Alarm Output Contact 8,

NORMALLY CLOSED

User defined

4 Q Major Audio Alarm,

RETURN

Predefined

4 R Major Audio Alarm,

NORMALLY OPEN

Predefined

4 S Major Audio Alarm,

NORMALLY CLOSED

Predefined

4 T Minor Visual Alarm,

RETURN

Predefined

4 U Minor Visual Alarm,

NORMALLY OPEN

Predefined

4 V Minor Visual Alarm,

NORMALLY CLOSED

Predefined

4 W Minor Bay Alarm,

RETURN

Predefined

4 X Minor Bay Alarm,

NORMALLY OPEN

Predefined

4 Y Minor Bay Alarm,

NORMALLY CLOSED

Predefined

a. When there is no power fault condition, the Normally Open contact is closed and the Normally Close contact is open. When both PEM-A and PEM-B have power fault condition, the Normally Open contact is open and Normally Close con-tact is closed. The power fault is defined as when the power input into PEM-A or PEM-B is out of working range.

Table 3-12 Alarm output contact pin assignments

Pin Description Function

TN780 Hardware Description Release 1.2UTStarcom Inc.

Page 112: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 3-18 UTStarcom Optical Line AmplifierPage 3-18

An alarm is raised when one of the fan fails. A failure requires replacement of the corresponding fan tray. The chassis will operate at below 40°C with a single fan tray.

Fan Tray LEDsThe fan trays have two status LEDs: POWER and FAULT LED are provided on each fan tray. The significance of a lit LED is described in Table 3-13 on page 3-18.

Technical SpecificationsTable 3-14 on page 3-18 gives the mechanical, electrical, environmental specifications and reliability data for the fan tray.

Air FilterA replacable air filter is necessary to filter out dust particles at the air intake of the OTC. Air is filtered at 80% dust arrestance. Depending upon the operational environment, the air filters have to be replaced at regular intervals, preferably once every 3 months.

Table 3-13 Visual alarm indicators on the fan tray

LED Color Description

POWER Green Indicates the presence (lit) or absence (dimmed) of power supply to the fan tray

FAULT Red Indicates the fault status of the fan tray

Table 3-14 Fan tray technical specifications

Type Parameter Specification

Mechanical specifications Height 7.75” / 197mm

Width 1.23” / 31mm

Depth 8.1” / 206mm

Weight 2.5lbs

Electrical specifications Power consumption 50W

Input voltage range -40V DC to -60V DC

Environmental specifications Operating temperature range Normal: 5deg C - 40deg C

Short term: -5deg C to 55deg C

Storage temperature range -40deg C to 70deg C

High relative humidity 90% non-condensing

Compliance Environmental, EMI & safety NEBS Level 3, CE, IEC, ETSI, EN/IEC60950

UTStarcom Inc.TN780 Hardware Description Release 1.2

Page 113: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 3-19UTStarcom Optical Line Amplifier

Technical Specifications

Card CageThe OTC contains a single card cage, with three slots. The card cage houses the circuit packs horizontally, as detailed in Table 3-16 on page 3-19.

Table 3-15 Air filter technical specifications

Type Parameter Specification

Mechanical specifications Height 0.65” / 17mm

Width 8.75” / 222mm

Depth 8.6” / 218mm

Weight less than 0.5lbs

Dust arrestance 80%

Compliance Fire rating UL Class II

Table 3-16 Circuit pack assignments in a OTC

Circuit Pack Name Abbreviation Reserved slot numbers in OTC

Optical Management Module OMM Top slot 1A and 1B

Optical Amplifier Module OAM Bottom two slots 2 and 3

TN780 Hardware Description Release 1.2UTStarcom Inc.

Page 114: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 3-20 UTStarcom Optical Line AmplifierPage 3-20

Optical Management Module (OMM)

Functional DescriptionThe OMM is a half height module that slides into the chassis in the top slot 1A and 1B. The OMM performs:

Shelf controller functions controlling the modules installed within the chassis.

Management gateway functions to the external DCN.

The OMM supports the local craft interfaces for local management access.

For high-availability, redundant OMMs can be deployed in each OTC. One OMM actively performs the node/shelf control functions while the other OMM is in the standby mode.

Table 3-17 OMM product details

Product Number Product Description

OMM-A Optical Management Module

UTStarcom Inc.TN780 Hardware Description Release 1.2

Page 115: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 3-21UTStarcom Optical Line Amplifier

Block Diagram

Figure 3-6 OMM functional block diagram

External Indicators and ConnectorsThe OMM has the circuit pack status LED indicators and craft Ethernet/Serial port connectors on the front panel as shown in Figure 3-7 on page 3-22.

CPU

RTC & NVRAMNAND Flash

EthernetSwitch

Front panelCraft serial

Front panelCraft

Ethernet

Flash RAM

Telemetry

Fan controls

Modem

Display controls

1-wire controls

Control and status

Timing controls and distribution

Chassis alarm

IO RelayFan A

Fan B

IO panel

Peer OMM switch

IO, Backplane and fans

Peer OMM, and OAM

Peer OMM, and OAM

Peer OMM, and OAM

Chassis alarm

IO RelayFan A

Fan B

IO panel

Peer OMM switch

IO, Backplane and fans

Peer OMM, and OAM

Peer OMM, and OAM

Peer OMM, and OAM

Bac

kplane

Con

nector

TN780 Hardware Description Release 1.2UTStarcom Inc.

Page 116: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 3-22 UTStarcom Optical Line AmplifierPage 3-22

Figure 3-7 OMM faceplate

Circuit Pack Level LEDsThe OMM has 4 LEDs to indicate the circuit pack status. The significance of an illuminated LED is described in Table 3-18 on page 3-22.

ConnectorsThe OMM has craft Ethernet and craft serial ports for management purposes (see Table 3-19 on page 3-22).

Table 3-18 OMM status LED indicators

LED Indicator Color Meaning

PWR (Power) Green Indicates the presence (lit) or absence (dimmed) of power supply to the OMM circuit pack

NC (Node Controller) Green Indicates the chassis function: Main Chassis or Expansion Chas-sis

ACT (Active) Green / Yellow Indicates the circuit pack status: Active or Standby

FLT (Fault) Red Indicates the presence (lit) or absence (dimmed) of an alarm on the circuit pack: Critical, Major or Minor

Table 3-19 OMM connectors

Connector Type Purpose

CRAFT10Base-T 10 Mbps RJ45 Used by maintenance personnel for managing the network element locally

CRAFT DCE 9600 RS232 DCE DB9 Female

Used by maintenance personnel for managing the network element locally

FLT,ACT,NC,PWR

Circuit Pack Status LEDs

EjectorEjector

Link Data

Craft Ethernet Status LEDs

Craft Ethernet

port

Craft RS232C

Serial port

TN780 Hardware Description Release 1.2

UTStarcom Inc.
Page 117: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 3-23UTStarcom Optical Line Amplifier

Technical SpecificationsTable 3-20 on page 3-23 provides the mechanical, electrical, environmental specifications and reliability data for the OMM.

Table 3-20 OMM technical specifications

Type Parameter Specification

Mechanical specifications Height 10.5” / 267mm

Width 1.03” / 26mm

Depth 8.53” / 217mm

Weight 2.5lbs

Electrical specifications Power consumption 35W (maximum for each module)

Input voltage range -40V DC to -60V DC

Environmental specifications Operating temperature range Normal: 5deg C - 40deg C

Short term: -5deg C to 55deg C

Storage temperature range -40deg C to 70deg C

High relative humidity 90% non-condensing

Compliance Environmental, EMI & safety NEBS Level 3, CE, IEC, ETSI, EN/IEC60950

TN780 Hardware Description Release 1.2UTStarcom Inc.

Page 118: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 3-24 UTStarcom Optical Line AmplifierPage 3-24

Optical Amplifier Module (OAM)There are 6 different OAM types providing different EDFA gain and with/without mid-stage access. Table 3-21 on page 3-24 provides the name and the function of each of the available OAMs.

OAM-CX-A Functional DescriptionThe OAM-CX-A can be equipped in Slots 2 and/or 3 of the OTC. The functions are:

Performs uni-directional in-line optical amplification of the incoming signal

Terminates the OSC for processing control and in-band management traffic

Provides optical insertion and extraction of the 1510nm OSC using a 1510nm optical filter

Provides a C/L-band splitter to enable an in-service expansion of the system to enable optical trans-mission in the L-band

Provides test access ports for power monitors or optical spectrum analyzers. This includes one receive monitor port and one transmit monitor port

Provides sub-slot access for OWM (future provision)

Accommodates mid-stage access DCF in 2 versions of OAM-CX-A

Note: If the mid-stage DCF is between 0 and 800 ps/nm, the addition of a 5dB attenuator is required for normal operations.

Table 3-21 OAM product details

Product Number Product Description

OAM-C1-A OAM, C band, 20 dB fixed gain, with VOA, without mid-stage access

OAM-C1-B OAM, C band, 20 dB fixed gain, with VOA, without mid-stage access

OAM-C2-MS-A OAM, C band, variable gain from 18 dB to 26 dB, with mid-stage access

OAM-C2-MS-B OAM, C band, variable gain from 18 dB to 26 dB, with mid-stage access

OAM-C3-MS-A OAM, C band, variable gain from 25 dB to 33 dB, with mid-stage access

OAM-C3-MS-B OAM, C band, variable gain from 25 dB to 33 dB, with mid-stage access

UTStarcom Inc.TN780 Hardware Description Release 1.2

Page 119: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 3-25UTStarcom Optical Line Amplifier

Note: If the mid-stage DCF is above 800 ps/nm then there is no requirement for the 5dB attenua-tor.

Note: Two OAMs are required in an OTC to perform bi-directional optical amplification.

OAM-CX-B Functional DescriptionThe OAM-CX-B can be equipped in Slots 2 and/or 3 of the OTC. The functions are:

Has an enhanced EDFA for increased reliability

Performs uni-directional in-line optical amplification of the incoming signal

Terminates the OSC for processing control and in-band management traffic

Provides optical insertion and extraction of the 1510nm OSC using a 1510nm optical filter

Provides a C/L-band splitter to enable an in-service expansion of the system to enable optical trans-mission in the L-band

Provides test access ports for power monitors or optical spectrum analyzers. This includes one receive monitor port and one transmit monitor port

Provides sub-slot access for OWM (future provision)

Accommodates mid-stage access DCF in 2 versions of OAM-CX-B

Note: Two OAMs are required in an OTC to perform bi-directional optical amplification.

Note: The enhanced EDFA eliminates the need for a 5b attenuator on the DCM port.

TN780 Hardware Description Release 1.2UTStarcom Inc.

Page 120: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 3-26 UTStarcom Optical Line AmplifierPage 3-26

Block Diagram

Figure 3-8 OAM control plane block diagram

Figure 3-9 OAM data plane diagram

CPU

Bac

kpla

ne C

onne

ctor

Flash RAM

10 / 100 Ethernet

Transceiver

10 / 100 Ethernet

Transceiver

EthernetSwitch

STS-3C / FE Mapper

OSC Transceiver

OWM

OW

M C

onne

ctor

INOUT

OSC

SC

SC

SC

VOA

MUX

DE-MUX

OUT

L-Band

IN

SC

SC

OSA monitor IN

OSA monitor OUT

SC

IN OUTDCM

SC

C-EDFA

OSC Tx OSC Rx INOUT LINE

OSCOUT IN

MUX

DE-MUX

SC

SC

SC

VOA

MUX

DE-MUX

OUT

L-Band

IN

SC

SC

OSA monitor IN

OSA monitor OUT

SC

IN OUTDCM

SC

C-EDFA

OSC Tx OSC Rx INOUT LINE

OSCOUT IN

MUX

DE-MUX

UTStarcom Inc.TN780 Hardware Description Release 1.2

Page 121: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 3-27UTStarcom Optical Line Amplifier

External Indicators and ConnectorsThe OAM has the circuit pack status LED indicators and craft Ethernet/Serial port connectors (see Figure 3-10 on page 3-27).

Figure 3-10 OAM faceplate

Circuit Pack Level LEDsThe OAM has three LEDs to indicate the circuit pack status. The significance of an illuminated LED is described in Table 3-22 on page 3-27.

Table 3-22 OAM status LED indicators

LED Indicator Color Meaning

FLT (Fault) Red Indicates the presence (lit) or absence (dimmed) of an alarm on the cir-cuit pack: Critical, Major or Minor

ACT (Active) Green / Yellow Indicates the circuit pack status: Active or Standby

PWR (Power) Green Indicates the presence (lit) or absence (dimmed) of power supply to the OAM circuit pack

Ejector OWM Circuit Pack

FLT ACT PWR

CLEI

IN OUT

O SA MO NITO R

to L-BAND to DCM

IN OUT

O AM -C2-MS

INVISIBLE LASERRADIATION

DO NOT VIEWDIRECTLY WITH

OPTICALINSTRUMENTS

CLASS 1M LASERPRODUCT (IEC)CLASS I LASER

PRODUCT (CDRH)1550nm-50mW

O SC

LO S LO S ACT

LINEOUT

IN

OUT

IN

OUT

IN

O W M -BLANK

INVISIBLE LASERRADIATION

DO NOT VIEWDIRECTLY WITH

OPTICALINSTRUMENTS

CLASS 1M LASERPRODUCT (IEC)CLASS I LASER

PRODUCT (CDRH)1550nm-50mW

L-Bandconnectors

Warning label

Port LEDsLOS ACT

Ejector

OSA Monitorconnectors for line input and

output OSC port DCM connectors

(present only inOAM4-C2-MS and

OAM4-C3-MS)

Line connectors

Handle

Circuit Pack Status LEDs

FLT, ACT, PWR(future provision)

UTStarcom Inc.

TN780 Hardware Desc ription Release 1.2
Page 122: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 3-28 UTStarcom Optical Line AmplifierPage 3-28

Port IndicatorsThere are two LEDs: ACTIVE and LOS for the OAM circuit pack to indicate the line port status. The significance of a lit LED is described in Table 3-23 on page 3-28.

ConnectorsThe OAM has connectors for the external fiber plant and management and control traffic (see Table 3-24 on page 3-28).

Table 3-23 Port visual alarm indicators on OAM circuit pack

LED State Description

ACT (Active) Green / Yellow Indicates the line port administrative status

LOS (Loss Of Signal)

Red Indicates the incoming signal or port configuration status

Table 3-24 OAM connectors

Connector Type Purpose

OSA Monitor IN SC, Front access Port to monitor line input

OSA Monitor OUT SC, Front access Ports to monitor line output

OSC IN SC, Front access OSC port connects to the OSC OUT of the other OAM circuit pack

OSC OUT SC, Front access OSC port connects to the OSC IN of the other OAM circuit pack

L-Band IN SC, Front access Port used to pass L-band channels

L-Band OUT SC, Front access Port used to pass L-band channels

DCM IN SC, Front access Connects to the DCM module on DMC

DCM OUT SC, Front access Connects to the DCM module on DMC

Line IN SC, Front access Connects from the line side fibers

Line OUT SC, Front access Connects to the line side fibers

UTStarcom Inc.TN780 Hardware Description Release 1.2

Page 123: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 3-29UTStarcom Optical Line Amplifier

Technical SpecificationsTable 3-25 on page 3-29 provides the mechanical, electrical, environmental specifications and reliability data for OAM.

The optical specification details are given in Table 3-26 on page 3-29.

Table 3-25 OAM technical specifications

Type Parameter Specification

Mechanical specifications Height 10.5” / 267mm

Width 3.2” / 82mm

Depth 8.53” / 217mm

Weight 8lbs

Electrical specifications Power consumption 30W

Input voltage range -40V DC to -60V DC

Environmental specifications Operating temperature range Normal: 5deg C - 40deg C

Short term: -5deg C to 55deg C

Storage temperature range -40deg C to 70deg C

High relative humidity 90% non-condensing

Compliance Environmental, EMI & safety NEBS Level 3, CE, IEC, ETSI, EN/IEC60950

Laser safety ANSI Class I, IEC Class 1M

Table 3-26 OAM optical specification

Type Parameter Specification

Line side optics Wavelength spacing 100GHz

Wavelength frequency range 1530.725-1563.455nm ITU Grid

OSC Wavelength 1510nm

Format STS-3/STM-1

TN780 Hardware Description Release 1.2UTStarcom Inc.

Page 124: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 3-30 UTStarcom Optical Line AmplifierPage 3-30

Blank Circuit PacksWhenever a circuit pack is removed, the blank space must be occupied by the corresponding blank circuit pack. Blank circuit packs serve three important functions:

Prevents exposure to hazardous voltage and currents inside the chassis

Contains any ElectroMagnetic Interference (EMI) that might damage other equipment

Directs the flow of cooling air through the chassis.

Table 3-27 on page 3-30 lists the corresponding blank circuit pack.

Table 3-27 OTC blank circuit packs

Product Number Product Description

OMM-BLANK Optical Management Module (OMM) blank

OAM-BLANK Optical Amplifier Module (OAM) blank

UTStarcom Inc.TN780 Hardware Description Release 1.2

Page 125: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

CHAPTER 4

UTStarcom Dispersion ManagementChassis

The Dispersion Management Chassis, referred to as a DMC, is a rack mountable passive chassis. The DMC does not require management. Depending on the span characteristics, the DMC is optionally included in TN780 and Optical Line Amplifier network elements to provide dispersion compensation.

This chapter provides the DMC functional description and technical specifications in the following sections:

“DMC Overview” on page 4-2

“DMC” on page 4-3

“Dispersion Compensation Module (DCM)” on page 4-5

For DMC installation procedures, refer to the UTStarcom TN780 Site Preparation and Hardware Installation Guide.

TN780 Hardware Description Release 1.2UTStarcom Inc.

Page 126: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 4-2 UTStarcom Dispersion Management ChassisPage 4-2

DMC OverviewThe DMC is comprised of a DMC and Dispersion Compensation Module(s) (DCM) as described in Table 4-1 on page 4-2.

A view of the DMC with two DCMs is shown in Figure 4-1 on page 4-2.

Figure 4-1 Dispersion Management Chassis

Table 4-1 DMC hardware equipment

Equipment Type Name Description

DMC Dispersion Management Chassis Refer to page 4-3Circuit Packs Dispersion Compensation Module Refer to page 4-5

UTStarcom Inc.TN780 Hardware Description Release 1.2

Page 127: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 4-3UTStarcom Dispersion Management Chassis

DMC

Functional DescriptionThe DMC supports the following functions:

Equalizes chromatic dispersion of different frequency components having different propagation speeds

Completely reverses the dispersion effect of transmission fiber and restores the optical signal

Performs optical dispersion compensation through the mid-stage access port (DCM) of the OAM and BMM

The chassis is entirely passive and does not require electrical connections to the chassis or within the chassis

Accommodates up to two DCMs for C-Band, standard single mode fiber

Has two different versions, one supporting the lower wavelengths, and the other supporting the higher wavelengths. The lower wavelength chassis (100-1300 psec/nm) will have removable/replaceable spools and the higher wavelength chassis (1400-1900 psec/nm) will have fixed spools

Can be installed in a 23” rack as flush mount and 1”, 2”, 5” and 6” forward mount or 600mmx600mm ETSI rack

Technical SpecificationsTable 4-3 on page 4-3 provides the mechanical, electrical, environmental specifications and reliability data for the DMC.

Table 4-2 DMC product details

Product Number Product Description

DMC1-A Dispersion Compensation Management Chassis

Table 4-3 DMC technical specifications

Type Parameter Specification

Mechanical specifications Height 1.75” / 45mm

Width 17.4” / 442mm

Depth 11.0” / 280mm

Weight 5.5lbs

TN780 Hardware Description Release 1.2UTStarcom Inc.

Page 128: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 4-4 UTStarcom Dispersion Management ChassisPage 4-4

Environmental specifications Operating temperature range Normal: 5 - 40deg C

Short term: -5deg C to 55deg C

Storage temperature range -40deg C to 70deg C

High relative humidity 90% non-condensing

Compliance Environmental, EMI & safety NEBS Level 3, CE, IEC, ETSI, EN/IEC60950

Table 4-3 DMC technical specifications

Type Parameter Specification

UTStarcom Inc.TN780 Hardware Description Release 1.2

Page 129: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 4-5UTStarcom Dispersion Management Chassis

Dispersion Compensation Module (DCM)

Functional DescriptionThe Dispersion Compensation Module, referred to as DCM, is a pluggable module that slides into the DMC.

The DCM supports the following functions:

Houses dispersion compensating fiber that is optically connected to an OAM or BMM mid-stage access port (DCM) through a front panel, duplex optical cable

The length of the optical cable depends upon the site requirements

Table 4-4 DCM product details

Product Number CLEI Code Product Description

DCM1H-100N-A WMDFZABFAA Half-width, 100ps/nm, Negative Dispersion

DCM1H-200N-A WMDFZB0FAA Half-width, 200ps/nm, Negative Dispersion

DCM1H-300N-A WMDFZA8FAA Half-width, 300ps/nm, Negative Dispersion

DCM1H-400N-A WMOGABYFAA Half-width, 400ps/nm, Negative Dispersion

DCM1H-500N-A WMOGABZFAA Half-width, 500ps/nm, Negative Dispersion

DCM1H-600N-A WMOGAB0FAA Half-width, 600ps/nm, Negative Dispersion

DCM1H-700N-A WMOGAB1FAA Half-width, 700ps/nm, Negative Dispersion

DCM1H-800N-A WMOGAB2FAA Half-width, 800ps/nm, Negative Dispersion

DCM1H-900N-A WMOGAB3FAA Half-width, 900ps/nm, Negative Dispersion

DCM1H-1000N-A WMOGAB4FAA Half-width, 1000ps/nm, Negative Dispersion

DCM1H-1100N-A WMOGAB5FAA Half-width, 1100ps/nm, Negative Dispersion

DCM1H-1200N-A WMOGAB6FAA Half-width, 1200ps/nm, Negative Dispersion

DCM1H-1300N-A WMOGAB7FAA Half-width, 1300ps/nm, Negative Dispersion

DCM1F-1400N-A WMOGAB8FAA Full-width, 1400ps/nm, Negative Dispersion

DCM1F-1500N-A WMOGAB9FAA Full-width, 1500ps/nm, Negative Dispersion

DCM1F-1600N-A WMOGACAFAA Full-width, 1600ps/nm, Negative Dispersion

DCM1H-100P-A WMOGACEFAA Half-width, +100ps/nm, Positive Dispersion

DCM1H-200P-A WMOGACFFAA Half-width, +200ps/nm, Positive Dispersion

DCM1F-300P-A WMOGACGFAA Full-width, +300ps/nm, Positive Dispersion

DCM1F-1700-A WMOGACBFAA Full-width, 1700ps/nm, Negative Dispersion

DCM1F-1800-A WMOGACCFAA Full-width, 1800ps/nm, Negative Dispersion

DCM1F-1900-A WMOGACDFAA Full-width, 1900ps/nm, Negative Dispersion

TN780 Hardware Description Release 1.2UTStarcom Inc.

Page 130: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 4-6 UTStarcom Dispersion Management ChassisPage 4-6

Supports 19 types of negative DCMs, ranging from 100 ps/nm to 1900 ps/nm in 100 ps/nm incre-ments

Supports 3 types of positive DCMs, ranging from 100 ps/nm to 300 ps/nm.

A view of the DCM is shown in Figure 4-2 on page 4-7.

UTStarcom Inc.TN780 Hardware Description Release 1.2

Page 131: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 4-7UTStarcom Dispersion Management Chassis

Figure 4-2 Dispersion Compensation Module

Technical SpecificationsTable 4-5 on page 4-7 provides the mechanical, electrical, environmental specifications and reliability data for DCM.

Table 4-5 DCM technical specifications

Type Parameter Specification

Mechanical specifications Height 1.6” / 41mm

Width Negative 100-1300 ps/nm: 8.64” / 220mm

Negative 1400-1900 ps/nm: 17.28” / 439mm

Positive 100-200 ps/nm: 8.64” / 220mm

Positive 300 ps/nm: 17.28” / 439mm

Depth 10.5” / 267mm

Weight Varies - <6lbs

TN780 Hardware Description Release 1.2UTStarcom Inc.

Page 132: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page 4-8 UTStarcom Dispersion Management ChassisPage 4-8

ConnectorsAll DCMs have two SC type connectors for optical interface (see Table 4-6 on page 4-8).

Environmental specifications Operating temperature range Normal: 5 - 40deg C

Short term: -5deg C to 55deg C

Storage temperature range -40deg C to 70deg C

High relative humidity 90% non-condensing

Compliance Environmental, EMI & safety NEBS Level 3, CE, IEC, ETSI, EN/IEC60950

Table 4-6 DCM connectors

Connector Type Purpose

2 SC Optical interface

Table 4-5 DCM technical specifications

Type Parameter Specification

UTStarcom Inc.TN780 Hardware Description Release 1.2

Page 133: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Appendix A

Acronyms

Table A-1 List of Acronyms

Abbreviation Description

AACLI application command line interface

ACO alarm cutoff

ACT active

AD add/drop

ADM add/drop multiplexer

ADPCM adaptive differential pulse code modulation

AGC automatic gain control

AID access identifier

AINS administrative inservice

AIS alarm indication signal

ALS automatic laser shutdown

AMP amplifier

ANSI American National Standards Institute

AO autonomous output

APD avalanche photo diode

API application programming interface

APS automatic protection switching

ARC alarm reporting control

ARP address resolution protocol

TN780 Hardware Description Release 1.2UTStarcom Inc.

Page 134: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page A-2 AcronymsPage A-2

ASAP alarm severity assignment profile

ASE amplified spontaneous emission

ASIC application-specific integrated circuit

ATM asynchronous transfer mode

AU administrative unit

AUX auxiliary port

AWG array waveguide gating

AWG american wire gauge

BBDFB battery distribution fuse bay

BDI backward defect indication

BDI backward defect indication

BEI backward error indication

BER bit error rate

BERT bit error rate testing

BGA ball grid array

BIP-8 bit interleaved parity

BITS building-integrated timing supply

BLSR bi-directional line switched ring

BMM-C Band Mux Module - C band

BNC Bayonet Niell-Concelman; British Naval Connector

BOL beginning of life

BOM bill of material

BOOTP bootstrap protocol

bps bits per second

BPV bipolar violations

CC Celsius

CCITT Consultative Committee on International Telegraph and Telephone

CCLI commissioning command line interface

CDE chromatic dispersion equalizer

CDR clock and data recovery

CDRH Center for Devices and Radiological Health

Table A-1 List of Acronyms

Abbreviation Description

UTStarcom Inc.TN780 Hardware Description Release 1.2

Page 135: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page A-3Acronyms

CFR code for federal regulations

CH/Ch/ch channel

CID circuit identifier

CIT craft interface terminal

CLEI common language equipment identifier

CLI command line interface

CO central office

CODEC coder and decoder

COM communication

CORBA common object request broker architecture

CPC common processor complex

CPE customer premises equipment

CPLD complex programmable logic device

CPU central processing unit

CRC cyclic redundancy check

CSPF constraint-based shortest path first algorithm

CSV comma separated value

CTAG correlation tag

CTP client termination point

CTS clear to send

CV coding violation

CV-L coding violation-line

CV-P coding violation-path

CV-S coding violation-section

DDA digital amplifier

dB decibel

DB database

DCC data communications channel

DCE data communications equipment

DCF dispersion compensation fiber

DCM dispersion compensation module

DCN data communication network

DEMUX de-multiplexing

Table A-1 List of Acronyms

Abbreviation Description

TN780 Hardware Description Release 1.2UTStarcom Inc.

Page 136: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page A-4 AcronymsPage A-4

DFB distributed feedback

DFE decision feedback equalizer

DGE dynamic gain equalization

DHCP dynamic host configuration protocol

DLM digital line module

DMC dispersion management chassis

DR digital repeater

DSF dispersion shifted fiber

DT digital terminal

DTC digital transport chassis

DTE data terminal equipment

DTF digital transport frame

DTL digital transport line

DTMF dual tone multi frequency

DTP digital transport path

DTS digital transport section

DWDM dense wavelength division multiplexing

EEDFA erbium doped fiber amplifier

EEPROM electrically-erasable programmable read only memory

EMC electromagnetic compatibility

EMI electro-magnetic interference

EMS element management system

EOL end-of-life

ESD electrostatic discharge; electrostatic-sensitive device

ES-L line-errored seconds

ES-P path-errored seconds

ES-S section-errored seconds

ETS IEEE european test symposium

ETSI European Telecommunications Standards Institute

FF fahrenheit

FA frame alignment

Table A-1 List of Acronyms

Abbreviation Description

UTStarcom Inc.TN780 Hardware Description Release 1.2

Page 137: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page A-5Acronyms

FAS frame alignment signal

FC fiber channel; failure count

FCAPS fault management, configuration management, accounting, performance monitor-ing, and security administration

FCC Federal Communications Commission (USA)

FDA Food and Drug Administration

FDI forward defect indication

FEC forward error correction

FIFO first-in-first-out

FIT failure in time

FLT fault

FPGA field programmable gate array

FRU field replaceable unit

FTP file transfer protocol

GGbE gigabit ethernet

Gbps gigabits per second

GCC general communication channel

GFP general framing protocol

GHz gigahertz

GMPLS generalized multi protocol label switching

GNE gateway network element

GNM graphical node manager

GUI graphical user interface

H/IHTML hypertext markup language

HTTP hypertext transfer protocol

IAP input, output and alarm panel

ID identification

IDF invalid data flag

IEC International Electrical Commission

I/O Input/Output

IOP input output panel

IP Internet protocol

Table A-1 List of Acronyms

Abbreviation Description

TN780 Hardware Description Release 1.2UTStarcom Inc.

Page 138: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page A-6 AcronymsPage A-6

IQ see IQ NOS

IQ NOS UTStarcom IQ network operating system

IR intermediate reach

IS in-service

ITU-T International Telecommunications Union - Telecommunications

J/K/LJDK Java Development Kit

JRE Java Runtime Environment

LAN local area network

LBC laser bias current

LC fiber optic cable connector type

LCK locked

LED light-emitting diode

Linear ADM linear add/drop multiplexer

LOF loss of frame

LOL loss of light

LOP loss of pointer

LOS loss of signal

LR long reach

LSB least significant bit

LTE line-terminating equipment

LVDS low voltage differential signaling

MMA monitoring access

MAC media access control

MB megabyte

Mb/s megabits per second

MIB management information base

MCM management and control module

MEMS micro electro mechanical systems

MFAS multi frame alignment signal

MIB management information base

MMF multimode fiber

Table A-1 List of Acronyms

Abbreviation Description

UTStarcom Inc.TN780 Hardware Description Release 1.2

Page 139: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page A-7Acronyms

MS multiplex section

MSA multi source agreement

MSB most significant bit

MSOH multiplex section overhead

MTBF mean time between failure

MTU maximum transmission unit

MX multiplex, multiplexer, multiplexing

NNA network administrator

NAND flash type

NC normally closed; node controller

NCC node controller chassis

NCT nodal control and timing

NDSF non zero dispersion shifted fiber

NE network engineer

NEBS network equipment building system

NECG net electrical coding gain

NEPA national fire protection association

NJO negative justification opportunity

nm nanometer

NML network management layer

NMS network management system

NNI network-to-network interface

NO normally open

NSA non-service affecting

NTP network time protocol

NVRAM nonvolatile random access memory

OOAM optical amplification module

OAM&P operation, administration, maintenance and provisioning

OC-12 optical carrier signal at 622.08 mb/s

OC-192 optical carrier signal at 9.95328 gb/s

OC-3 optical carrier signal at 155.52 mb/s

Table A-1 List of Acronyms

Abbreviation Description

TN780 Hardware Description Release 1.2UTStarcom Inc.

Page 140: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page A-8 AcronymsPage A-8

OC-48 optical carrier signal at 2.48832 gb/s

OCG optical carrier group

Och Optical channel

OCI open connection indication

ODU optical channel data unit

OEO optical-electrical-optical conversion

OFC open fiber control

OH overhead

OIF optical internetworking forum

OLA optical line amplifier

OMM optical management module

OMS optical multiplex section

OOS out-of-service

OOS-MT out-of-service maintenance

OPR optical power received

OPT optical power transmitted

OPU optical channel payload unit

ORL optical return loss

OS operating system

OSA optical spectrum analyzer

OSC optical supervisory channel

OSNR optical signal-to-noise ratio

OSPF open shortest path first

OSS operations support system

OTC optical transport chassis

OTDR optical time domain reflectometer

OTN optical transport network

OTS optical transport section

OTU optical channel transport unit

OW orderwire

OWM orderwire module

P/QPC personal computer

PCPM per channel power monitoring

Table A-1 List of Acronyms

Abbreviation Description

UTStarcom Inc.TN780 Hardware Description Release 1.2

Page 141: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page A-9Acronyms

PDU protocol data unit; power distribution unit

PEM power entry module

PF partial failure

PG protection group

PHY physical

PIC photonic integrated circuit

PID protocol identifier

PIN positive-intrinsic negative

PJO positive justification opportunity

PLD programmable logic device

PLL phase locked loop

PM performance monitoring

PMD polarization mode dispersion

POH path overhead

POP point-of-presence

PPM part per million

PPP point-to-point protocol

PR provisioning

PRBS pseudo random binary sequence

ps pico second (unit of measure for dispersion)

PSC protection switch completion; protection switch count

PSD protection switch duration

PSTN public switched telephone network

PT parallel telemetry

PTP physical termination point; point-to-point

PWR power

QOS quality of service

RRAM random access memory

RDI remote defect indication

REI-L remote error indication-line

REI-P remote error indication-path

RFI remote failure indication

ROM read-only memory

Table A-1 List of Acronyms

Abbreviation Description

TN780 Hardware Description Release 1.2UTStarcom Inc.

Page 142: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page A-10 AcronymsPage A-10

RS regenerator section; reed solomon

RSOH regenerator section overhead

RTC real time clock

RTN return lead

RTS ready to send

RU rack unit

Rx receiver; receive

Rx Q receiver quality

SSA service affecting; security administrator

SAPI source access point identifier

SC square shaped fiber optic cable connector

SD signal degrade

SDH synchronous digital hierarchy

SDRAM synchronized dynamic random access memory

SEF severely errored frame

SEFS severely errored frame second

SELV safety extra low voltage

SERDES serializer and deserializer

SES severely errored seconds

SF signal fail

SFP small form factor plug

SID source identifier; system identifier

SMF single-mode fiber

SML service management layer

SNC sub network connection

SNE subtending network element

SNMP simple network management protocol

SNR signal-to-noise ratio

SOH section overhead

SOL start of life

SONET synchronous optical network

SPE synchronous payload envelope

SQ signal quality

Table A-1 List of Acronyms

Abbreviation Description

UTStarcom Inc.TN780 Hardware Description Release 1.2

Page 143: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page A-11Acronyms

SR short reach

SSL secure sockets layer

STE section terminating equipment

STM synchronous transfer mode

STM-1 SDH signal at 155.52 Mb/s

STM-16 SDH signal at 2.48832 Gb/s

STM-4 SDH signal at 622.08 Mb/s

STM-64 SDH signal at 10 Gb/s

STM-n synchronous transport module of level n (for example, STM-64, STM-16)

STS synchronous transport signal

STS-n synchronous transport signal of level n (for example, STS-12, STS-48)

SW software

T/U/VTAM tributary adapter module

TAP timing and alarm panel

TCA Threshold Crossing Alert

TCP transmission control protocol

TE traffic engineering

TEC thermo-electric cooler

TERM terminal

TFTP trivial file transfer protocol

TID target identifier

TIM trace identifier mismatch

TL1 transaction language 1

TMN telecommunications management network

TOM tributary optical module

TP termination point

TR transceiver

TT test and turn-up

TTI trail trace identifier

Tx Transmitter; Transmit

UA unavailable seconds

UART universal asynchronous receiver transmitter

UAS unavailable seconds

Table A-1 List of Acronyms

Abbreviation Description

TN780 Hardware Description Release 1.2UTStarcom Inc.

Page 144: UTStarcom TN780info-sourcing.com/clients/INFINERA PROJECT/Documents/Documents … · UTStarcom TN780 Hardware Description Guide Release 1.2 Revision B Product Order No. TN780-HWG-1.2-B

Page A-12 AcronymsPage A-12

UAS-L unavailable seconds, near-end line

UAS-P unavailable seconds, near-end STS path

UDP user datagram protocol

UPSR unidirectional path switched ring

URL universal resource locator

UTC Coordinated Universal Time

V volt

VGA variable gain amplifier

VLAN virtual local area network

VOA variable optical attenuator

VPN virtual private network

VSR very short reach

W/X/Y/ZWAN wide area network

WDM wavelength division multiplexing

XC cross-connect

XFP name of a small form factor 10 Gbps optical transceiver

XML extensible markup language

MISC1R re-amplification

2R re-amplification, re-shape

3R re-amplification, re-shape, re-time

4R re-amplification, re-shape, re-time, re-code

Table A-1 List of Acronyms

Abbreviation Description

UTStarcom Inc.TN780 Hardware Description Release 1.2