97
Addendum-01a Equipment Calibrations My ASNT Level III UT Study Notes. 2014-June

Ut testing add01a equipment calibrations

Embed Size (px)

DESCRIPTION

 

Citation preview

Page 1: Ut testing add01a equipment calibrations

Addendum-01aEquipment Calibrations My ASNT Level III UT Study Notes.2014-June

Page 2: Ut testing add01a equipment calibrations
Page 3: Ut testing add01a equipment calibrations
Page 4: Ut testing add01a equipment calibrations
Page 5: Ut testing add01a equipment calibrations

http://en.wikipedia.org/wiki/Greek_alphabet

Page 6: Ut testing add01a equipment calibrations

Speaker: Fion Zhang2014/6/19

Page 7: Ut testing add01a equipment calibrations
Page 8: Ut testing add01a equipment calibrations

Normal Beams Calibration Techniques

Page 9: Ut testing add01a equipment calibrations

Attenuation due to Beam spread for: Large Reflector Small Reflector

Page 10: Ut testing add01a equipment calibrations

Attenuation Due to Beam Spread: Large Reflector

Page 11: Ut testing add01a equipment calibrations

Attenuation Due to Beam Spread: Small Reflector

D2

D1

SH1

SH2

Page 12: Ut testing add01a equipment calibrations

Material Attenuation Determination:

Page 13: Ut testing add01a equipment calibrations

Material Attenuation Determination: Actual BWE display

Page 14: Ut testing add01a equipment calibrations

IF zero Material attenuation: The second BWE at twice the distance will be exactly 6dB less (50% less), half the 1st BWE height ( ½ FSH). However this is never the case!

Page 15: Ut testing add01a equipment calibrations

Δ dB = total Material attenuation at twice distance travel.

Material attenuation =

D2D1

ΔdB

Page 16: Ut testing add01a equipment calibrations

Material Attenuation in 100mm = YdB-XdB-6dBMaterial attenuation in dB/mm = (YdB-XdB-6dB)/100

Y dBX dB

YdB-XdB-6dB

Page 17: Ut testing add01a equipment calibrations

Construction of beam edges plot- Normal Transducer

Page 18: Ut testing add01a equipment calibrations

Construction of Beam Edges:

Page 19: Ut testing add01a equipment calibrations

20dB drop to find edges of beam

Page 20: Ut testing add01a equipment calibrations

The other edge:

Page 21: Ut testing add01a equipment calibrations

Construction of beam spread at 13mm:

Page 22: Ut testing add01a equipment calibrations

Construction of beam spread at 25mm:

Page 23: Ut testing add01a equipment calibrations

Construction of beam spread at 32mm:

Page 24: Ut testing add01a equipment calibrations

Angle Beams Calibration Techniques

Page 25: Ut testing add01a equipment calibrations

Perspex as Matching Layer/Wedge

2730m/s

3250m/s

θs1

θs2

Tunsten impregnated epoxy resin

Page 26: Ut testing add01a equipment calibrations

Perspex as Matching Layer/Wedge

1. The Shear wave velocity of Perspex is 2730m/s, the shear wave velocity od steel is 3250m/s. The refracted angle of Perspex ϴS1 is always smaller than ϴS2

2. Pespex is very absortive and attenuated efficiently, thus reflected compressional wavw will be dampen.

Page 27: Ut testing add01a equipment calibrations

First/ Second Critical Angles

B

VL1= 2730m/s,

VS2= 3250m/s, VL2= 5900m/s

1st / 2nd critical angle

Ist Critical angle= 27.56°

2nd Critical angle= 57.14°°

27.56°

57.14°

33.42°

Page 28: Ut testing add01a equipment calibrations

First/ Second Critical Angles

°

27.56°

57.14°

33.42°

Page 29: Ut testing add01a equipment calibrations

Finding the probe index

Page 30: Ut testing add01a equipment calibrations

Finding the probe index

Page 31: Ut testing add01a equipment calibrations

Checking the probe Angle:

Page 32: Ut testing add01a equipment calibrations

Calibration for range:

Page 33: Ut testing add01a equipment calibrations

Calibration for range:

Page 34: Ut testing add01a equipment calibrations

Angle Beam- Beam edges Proving (Vertical Axis) using IOW BlockStand Off Measurement Techniques.

Stand off 2

Stand-off 2

Stand-off 1

Page 35: Ut testing add01a equipment calibrations

Angle Beam- Beam edges Proving (Vertical Axis) using IOW BlockBotoom edge.

Page 36: Ut testing add01a equipment calibrations

Angle Beam- Beam edges Proving (Vertical Axis) using IOW BlockBottom Edge.

Page 37: Ut testing add01a equipment calibrations

The IOW Block: The Institute of Welding Block

Page 38: Ut testing add01a equipment calibrations

The Proofing:Plot out the Stand-Off1 & 2 readings on a transparent slide, superimposed the ploted transparent slide on IOW Block

Page 39: Ut testing add01a equipment calibrations

Angle Beam- Beam edges Proving (Horizontal Axis) using IIW Block

Page 40: Ut testing add01a equipment calibrations

Angle Beam- Beam edges Proving (Horizontal Axis) using IIW Block

Page 41: Ut testing add01a equipment calibrations

Angle Beam- Beam edges Proving (Horizontal Axis) using IIW Block

Scanned at ½ , 1, 1 ½ Skips

Page 42: Ut testing add01a equipment calibrations

Angle Beam- Beam edges Proving (Horizontal Axis) using IIW Block

Page 43: Ut testing add01a equipment calibrations

Angle Beam- Beam edges Proving (Horizontal Axis) using IIW Block

½ Skip

1 Skip1½ Skip

Page 44: Ut testing add01a equipment calibrations

The DAC

Page 45: Ut testing add01a equipment calibrations

The DAC

Page 46: Ut testing add01a equipment calibrations

DAC Curve

Page 47: Ut testing add01a equipment calibrations

DAC Curve

Page 48: Ut testing add01a equipment calibrations

DAC Curve Plot

1. Obtained the signal from the refernce reflector and mark on the graticule/traspatrent sheet with gain setting at 80% FSH.

2. Set the gain control -6bB and marks the 50% mark.

3. Set the gain contril to the

4. Obtained the signal at the gain setting in item 1 and repeat the process at different sound paths.

5. Plot the curves at the gain setting and -6dB.

6. Determined the transfer correction.

7. Scanned the work pieces at the “Gain Setting + Transfer Correction”

Page 49: Ut testing add01a equipment calibrations

FLAT Bottom Holes FBH

Page 50: Ut testing add01a equipment calibrations

FLAT Bottom Holes FBH

Page 51: Ut testing add01a equipment calibrations

Reading on: FLAT Bottom Holes FBH

https://www.cnde.iastate.edu/ultrasonics/grain-noise

Page 52: Ut testing add01a equipment calibrations

FLAT Bottom Holes FBHA type of reflector commonly used in reference standards. The end (bottom) surface of the hole is the reflector.Equivalent:, the size of a flat-bottom hole which at the same range, gives an ultrasonic indication equal to the one from the discontinuity. This reflector is used in DGS curves, or many calibration blocks, or standards such as the GE specification.

Page 53: Ut testing add01a equipment calibrations

Transfer Corection

Page 54: Ut testing add01a equipment calibrations

Transfer Correction: Reference surface are smooth and scale free unlike the actual work pieces. These call for transfer correction to account for transfer loss resulting from actual scanning.

Page 55: Ut testing add01a equipment calibrations

Transfer Correction: Reference surface are smooth and scale free unlike the actual work pieces. These call for transfer correction to account for transfer loss resulting from actual scanning.

Page 56: Ut testing add01a equipment calibrations

Transfer Correction: Reference surface are smooth and scale free unlike the actual work pieces. These call for transfer correction to account for transfer loss resulting from actual scanning.

Page 57: Ut testing add01a equipment calibrations

Transfer Correction:

Page 58: Ut testing add01a equipment calibrations

Transfer Correction: Comparison of BWE for Compression ProbeG

ain

Setti

ng

Beam path

Reference Block curve

Test Material curve

Transfer correction at thickness

Measured point

Page 59: Ut testing add01a equipment calibrations

Transfer Correction: Compression Probe Method, Plot a curve of gain setting for FSH at different south paths for actual and reference block, the different in gain control at thickness is the transfer correction.

Page 60: Ut testing add01a equipment calibrations

Transfer Correction: Angle Probes Methos, used 2 eaqual angle probes, pitch and catch in the test material ans using the reference block. The differences in gain setting is the transfer correction,

Page 61: Ut testing add01a equipment calibrations

DGS- Distance Gain Size

http://www.sonostarndt.com/EnProductShow.asp?ID=198

Page 62: Ut testing add01a equipment calibrations

FLAT Bottom Holes FBH

■ DGS/AVG

DGS is a sizing technique that relates the amplitude of the echo from a reflector to that of a flat bottom hold at the same depth or distance. This is known as Equivalent Reflector Size or ERS. DGS is an acronym forDistance/Gain/Size and is also known as AVG from its German name, Abstand Verstarkung Grosse. Traditionally this technique involved manually comparing echo amplitudes with printed curves, however contemporary digital flaw detectors can draw the curves following a calibration routine and automatically calculate the ERS of a gated peak. The generated curves are derived from the calculated beam spreading pattern of a given transducer, based on its frequency and element diameter using a single calibration point. Material attenuation and coupling variation in the calibration block and test specimen can be accounted for.

http://www.olympus-ims.com/en/ndt-tutorials/flaw-detection/dgs-avg/

Page 63: Ut testing add01a equipment calibrations

DGS is a primarily mathematical technique originally based on the ratio of a circular probe’s calculated beam profile and measurable material properties to circular disk reflectors. The technique has since been further applied to square element and even dual element probes, although for the latter, curve sets are empirically derived. It is always up to the user to determine how the resultant DGS calculations relate to actual flaws in real test pieces.

An example of a typical DGS curve set is seen below. The uppermost curve (Curve #1) represents the relative amplitude of the echo from a flat plate reflector in decibels, plotted at various distances from the transducer, and the curves below (Curve #2) represent the relative amplitude of echoes from progressively smaller disk reflectors over the same distance scale.

Page 64: Ut testing add01a equipment calibrations

(Curve #1) represents the relative amplitude of the echo from a flat plate reflector in decibels, plotted at various distances from the transducer

Page 65: Ut testing add01a equipment calibrations

(Curve #2) represent the relative amplitude of echoes from progressively smaller disk reflectors over the same distance scale.

Page 66: Ut testing add01a equipment calibrations

As implemented in contemporary digital flaw detectors, DGS curves are typically plotted based on a reference calibration off a known target such as a backwall reflector or a flat bottom hole at a given depth. From that one calibration point, an entire curve set can be drawn based on probe and material characteristics. Rather than plotting the entire curve set, instruments will typically display one curve based on a selected reflector size (registration level) that can be adjusted by the user. In the example below, the upper curve represents the DGS plot for a 2 mm disk reflector at depths from 10 mm to 50 mm. The lower curve is a reference that has been plotted 6 dB lower.

In the screen at left, the red gate marks the reflection from a 2 mm diameter flat bottom hole at approximately 20 mm depth. Since this reflector equals the selected registration level, the peak matches the curve at that depth. In the screen at right, a different reflector at a depth of approximately 26 mm has been gated. Based on its height and depth in relation to the curve the instrument calculated an ERS of 1.5 mm.

Page 67: Ut testing add01a equipment calibrations

(Curve #2) represent the relative amplitude of echoes from progressively smaller disk reflectors over the same distance scale.

Page 68: Ut testing add01a equipment calibrations

More reading on DGS

Page 69: Ut testing add01a equipment calibrations

DGS- Different sizes of FBH at different distance

Page 70: Ut testing add01a equipment calibrations

DGS

# of near field

Page 71: Ut testing add01a equipment calibrations

What is DGSTCG is a time-corrected DAC so that equal dimension reflectors give equal amplitude responses for all sound path distances. Used for PAUT Sectorial scans where it would be otherwise impossible to set every angle and sound path to the same sensitivity level using DAC's.

ASTM E-1316: DGS (distance gain size-German AVG) distance amplitude curves permitting prediction of reflector size compared to the response from a back surface reflection.

The probe manufacturer supplies data sheet diagams for each probe which shows the amplitude response curves from the backwall and a range of diameters of flat-bottom holes along the length of the soundfield. Have a look at EN 583-2:2001 Sensitivity and range setting for excellent authoritativedescriptions of DAC/TCG and DGS. You'll have to look at AWS D1.1. for instance for knowledge of their sensitivity setting requirements.Knowledge of these techniques is desirable but will such knowledge really improve your inspection method? You use DAC because the Codes and standards you work to require you to assess indications to those DAC's. A report that a reflector was 3,5 mm equivalent FBH size to DGS would most probably be rejected.

Page 72: Ut testing add01a equipment calibrations

DGS-If you have a signal feom a flaw at a certain depth, you can compare the signal of BWE from the FBH at that depth. The defect then could be sized as equivalent of the size of the FBH.

2.4depth

Size 0.24

Size 0.24

http://www.ndt.net/article/berke/berke_e.htm

Page 73: Ut testing add01a equipment calibrations

Locating & Sizing Flaws

Page 74: Ut testing add01a equipment calibrations

Locating reflectors with an angle-beam probe

Fig. 53 Scanning a reflector using an angle beam probe The echo of a discontinuity on the instrument display does not now give us any direct information about its position in the material. The only available information for determination of the reflector position is the scale position and therefore the sound path s, this means the distance of the discontinuity from the index point (sound exit point) of the probe, Fig. 53.

The mathematics of the right-angled triangle helps us to evaluate the Surface Distance and the Depth of a reflector which are both important for the ultrasonic test, Fig. 54a. We therefore now have the possibility to instantly mark a detected flaw's position on the surface of the test object by measurement of the surface distance from the sound exit point and to give the depth. For practical reasons, the reduced surface distance is used because this is measured from the front edge of the probe. The difference between the surface distance and the reduced surface distance corresponds to the x-value of the probe, this is the distance of the sound exit point to the front edge of the probe, Fig. 54b.

Page 75: Ut testing add01a equipment calibrations

With ultrasonic instruments having digital echo evaluation these calculations are naturally carried out by an integrated microprocessor and immediately displayed so that the operator does not need to make any more time-consuming calculations, Fig. 55. This is of great help with weld testing because with the calculation of the flaw depth an additional factor must be taken into account, namely: whether the sound pulses were reflected from the opposing wall. If this is the case then an apparent depth of the reflector is produced by using the depth formula which is greater than the thickness T of the test object. The ultrasonic operator must acertain whether a reflection comes from the opposite wall and then proceed with calculating the reflector depth, Fig. 56b.

Page 76: Ut testing add01a equipment calibrations

Scanning Patterns

Page 77: Ut testing add01a equipment calibrations

Scanning Patterns

Page 78: Ut testing add01a equipment calibrations

Scanning Patterns

Page 79: Ut testing add01a equipment calibrations

Scanning Patterns

Page 80: Ut testing add01a equipment calibrations

Scanning Patterns

Page 81: Ut testing add01a equipment calibrations

Scanning Patterns

Page 82: Ut testing add01a equipment calibrations

Scanning Patterns

Page 83: Ut testing add01a equipment calibrations

Scanning Patterns

Page 84: Ut testing add01a equipment calibrations

Scanning Patterns

Page 85: Ut testing add01a equipment calibrations

Scanning Patterns

Page 86: Ut testing add01a equipment calibrations

Scanning Patterns

Page 87: Ut testing add01a equipment calibrations

Scanning Patterns

Page 88: Ut testing add01a equipment calibrations

Scanning Patterns

Page 89: Ut testing add01a equipment calibrations

Scanning Patterns

Page 90: Ut testing add01a equipment calibrations

Scanning Patterns

Page 91: Ut testing add01a equipment calibrations
Page 92: Ut testing add01a equipment calibrations
Page 93: Ut testing add01a equipment calibrations
Page 94: Ut testing add01a equipment calibrations
Page 95: Ut testing add01a equipment calibrations

Scanning Patterns

http://www.olympus-ims.com/en/ndt-tutorials/flaw-detection/common-test-practices/

Page 96: Ut testing add01a equipment calibrations

Practice Makes Perfect

81. The 100 mm radius in an IIW block is used to:(a) Calibrate sensitivity level(b) Check resolution(c) Calibrate angle beam distance(d) Check beam angle

80. The 50 mm diameter hole in an IIW block is used to:(a) Determine the beam index point(b) Check resolution(c) Calibrate angle beam distance(d) Check beam angle

Page 97: Ut testing add01a equipment calibrations

Practice Makes Perfect

35. The 2 mm wide notch in the IIW block is used to:(a) Determine beam index point(b) Check resolution(c) Calibrate angle beam distance(d) Check beam angle