30
MEGAPOWER 168 / AD2088 OPERATION AND PROGRAMMING REFERENCE GUIDE (8200-0170-01, REV. A) 1 of 30 Using MegaPower 168 Matrix Switcher with AD2088 Keyboard Controller Operation and Programming Reference Guide Figure 1: MegaPower 168 (AD168) Typical Configuration AD168 Figure 2: AD2088 Keyboard Controller VCR F1 F2 SI T E RUN 1 2 3 6 5 4 7 8 9 0 M O N C AM SL OTS LAST NEXT OPE RATE M ENU VCR ACK FAR T ASK FO CU S O P E N I R I S ON OFF SITE C AMERA MON I T OR EN TER CO NT R OL PRE SET © Sensormatic 2002 ADTTE Touch Tracker AD2088 Keyboard Parallel Printer Port (standard) AD High Speed Data Line (standard) Control Code Modules (optional) Code Distributor (optional) Outputs 1-12 Dome Fixed Camera PTZ 168 Inputs Manchester RS-422 SensorNet

Using MegaPower 168 Matrix Switcher with AD2088 Keyboard …americandynamics.net/WebApps/getDocument.aspx?filename=8200-0170... · MEGAPOWER 168 / AD2088 OPERATION AND PROGRAMMING

Embed Size (px)

Citation preview

Page 1: Using MegaPower 168 Matrix Switcher with AD2088 Keyboard …americandynamics.net/WebApps/getDocument.aspx?filename=8200-0170... · MEGAPOWER 168 / AD2088 OPERATION AND PROGRAMMING

MEGAPOWER 168 / AD2088 OPERATION AND PROGRAMMING REFERENCE GUIDE (8200-0170-01, REV. A)

1 of 30

Using MegaPower 168 Matrix Switcher with AD2088 Keyboard Controller Operation and Programming Reference Guide

Figure 1: MegaPower 168 (AD168) Typical Configuration

AD168

Figure 2: AD2088 Keyboard Controller

VCRF1 F2

SITE

RUN1 2 3

654

7 8 9

0MON CAM

SLOTS

LAST NEXT

OPERATE

MENUVCR ACK

FAR

TASK

FOCUS

OPEN

IRIS

ONOFF

SITECAMERA

MONITORENTER CONTROL

PRESET

© Sensormatic 2002

ADTTE Touch Tracker

AD2088 Keyboard

Parallel Printer Port (standard)

AD High Speed Data Line (standard)

Control Code Modules(optional)

Code Distributor (optional)

Outputs 1-12

Dome

Fixed Camera

PTZ

168 InputsManchester

RS-422

SensorNet

Page 2: Using MegaPower 168 Matrix Switcher with AD2088 Keyboard …americandynamics.net/WebApps/getDocument.aspx?filename=8200-0170... · MEGAPOWER 168 / AD2088 OPERATION AND PROGRAMMING

MEGAPOWER 168 / AD2088 OPERATION AND PROGRAMMING REFERENCE GUIDE (8200-0170-01, REV. A)

2 of 30

Contents About this Guide ............................................................ 2

If you need assistance... ......................................... 2 About the MegaPower 168 Matrix Switcher/Controller System........................................................................... 3 About the AD2088 Keyboard Controller ......................... 3 General User Tasks ....................................................... 5

Logging On ............................................................. 5 Logging Off ............................................................. 6 Selecting Monitor or VCR Mode.............................. 6

Working in Operate Mode .............................................. 6 Selecting Monitors .................................................. 7 Selecting Cameras and Domes .............................. 7 Locking Cameras and Domes................................. 7 Controlling Cameras and Domes............................ 8 Calling Presets........................................................ 9 Running Patterns .................................................... 9 Holding Patterns ..................................................... 9 Patterns and Older SpeedDome Camera Domes... 9 Controlling Tours................................................... 10 Running Macros.................................................... 10 Controlling Auxiliary Devices................................. 11 Controlling VCRs .................................................. 11 Acknowledging Alarms.......................................... 12 Running Salvos..................................................... 12

Working in Program Mode ........................................... 13 Pattern Programming............................................ 13 Programming Preset Scenes ................................ 14 Programming Monitor Tours ................................. 14 Monitor Arming...................................................... 15 Programming Macros............................................ 17 Resetting the System............................................ 17 Setting the Date Format........................................ 17 Text Display Arrangement .................................... 17 Adjusting Text Display Position............................. 18 Detecting Camera Video Loss .............................. 18 Audio Alarm Programming.................................... 19

Working in Menu Mode ................................................ 20 Exiting from the Menu System .............................. 20 Using the Main Selection Menu ............................ 21 Changing the Language Setting............................ 21 Changing System Settings.................................... 21 Changing System Options .................................... 22 Changing Time and Date Settings ........................ 23 Changing Port Settings ......................................... 24 Changing Monitor Settings.................................... 25 Changing Camera Settings................................... 26 Configuring User or Keyboard Settings................. 28 Changing User Settings ........................................ 29 Changing Keyboard/Priority Settings .................... 29 Configuring Priority Settings ................................. 30

About this Guide This operation and reference guide explains tasks you can perform using the AD2088 keyboard with the MegaPower 168 (AD168) Matrix Switcher. It supplements material found in the following documents:

• AD2088 Keyboard Operator’s Manual, 8000-1811-01

• MegaPower 168 (AD168) Matrix Switcher/ Controller System Administrator’s Manual, 8000-0935-01

If you need assistance... Contact your Sales Representative.

WARRANTY DISCLAIMER: Sensormatic Electronics Corporation makes no representation or warranty with respect to the contents hereof and specifically disclaims any implied warranties of merchantability or fitness for any particular purpose. Further, Sensormatic Electronics Corporation reserves the right to revise this publication and make changes from time to time in the content hereof without obligation of Sensormatic Electronics Corporation to notify any person of such revision or changes. LIMITED RIGHTS NOTICE: For units of the Department of Defense, all documentation and manuals were developed at private expense and no part of it was developed using Government Funds. The restrictions governing the use and disclosure of technical data marked with this legend are set forth in the definition of “limited rights” in paragraph (a) (15) of the clause of DFARS 252.227.7013. Unpublished - rights reserved under the Copyright Laws of the United States. TRADEMARK NOTICE: MegaPower, American Dynamics and the American Dynamics logo are trademarks or registered trademarks of Sensormatic Electronics Corporation. Other product names mentioned herein may be trademarks or registered trademarks of Sensormatic or other companies. No part of this guide may be reproduced in any form without written permission from Sensormatic Electronics Corporation. BSL 11/2002

Page 3: Using MegaPower 168 Matrix Switcher with AD2088 Keyboard …americandynamics.net/WebApps/getDocument.aspx?filename=8200-0170... · MEGAPOWER 168 / AD2088 OPERATION AND PROGRAMMING

MEGAPOWER 168 / AD2088 OPERATION AND PROGRAMMING REFERENCE GUIDE (8200-0170-01, REV. A)

3 of 30

About the MegaPower 168 Matrix Switcher/Controller System The MegaPower 168 (AD168) Matrix Switcher/ Controller System is an integrated CCTV matrix switching and control system for CCTV surveillance systems with multiple video inputs, outputs, and control stations. Video inputs are typically provided by local or remote cameras and other video sources. Video output is viewed on monitors, or recorded on VCRs or digital video recorders located at system control points. In addition to providing video input and output switching, the AD168 system can respond to alarms and perform auxiliary switching for the control of gates, doors, lights, and other output devices. Depending on the control requirements of a given application, various AD keyboards and accessory devices can be used in concert with the system bays, cameras, and monitors.

The AD168 Matrix Switcher/Controller System is designed to support plug-in modules having a broad range of functionality. Plug-in modules include:

• Power Supply module • Central Processing module (CPM) • Video Input modules • Video Output modules • Optional Control Code modules Built-in expansion capabilities permit the addition of a second AD168 Bay to increase the number of video output devices supported.

External communications to system devices can be achieved through a variety of protocols, including Manchester Control Code, RS-232, RS-422, and SensorNet. A parallel printer port is standard with each AD168 system to provide printed copies of operating parameters and alarm events.

About the AD2088 Keyboard Controller The AD2088 keyboard is a video control station that is fully compatible with the AD168 matrix switcher/controller systems. The keyboard provides the following operating modes: Operate, Program, and Menu.

Operate mode does not require key privileges and provides the following functions:

• Monitor and camera selection

• Camera and dome control

• VCR control

• Preset, pattern, salvo and system tour recall

• Auxiliary control

• Alarm acknowledgment

Operators with key privileges may use Program and Menu modes. Program mode provides the following functions:

• Preset (target), pattern, and scratch-pad tour programming

• Macro programming

• Alarm monitor arming and disarming

Menu mode enables operators to set up the parameters of the connected switching system.

Figure 3 illustrates the AD2088 keyboard.

Page 4: Using MegaPower 168 Matrix Switcher with AD2088 Keyboard …americandynamics.net/WebApps/getDocument.aspx?filename=8200-0170... · MEGAPOWER 168 / AD2088 OPERATION AND PROGRAMMING

MEGAPOWER 168 / AD2088 OPERATION AND PROGRAMMING REFERENCE GUIDE (8200-0170-01, REV. A)

4 of 30

Figure 3: AD2088 keyboard features

SITE CAMERAMONITOR

VCR

F1 F2

SITE

RUN SLOTS 1 2 3

654

7 8 9

0MON CAMLAST NEXT

OPERATE

MENUVCR ACK

FAR

TASK

FOCUS

OPEN

IRIS

ONOFF

ENTER CONTROL

PRESET

1. Site Display: Shows the number of the site entered with the keypad when the SITE key (X) is pressed.

2. Monitor / VCR Display: Shows the number of the monitor or VCR entered with the keypad when the MON (N) or VCR (K) key is pressed. An LED illuminates to indicate the current mode.

3. Camera Display: Shows the number of the camera entered with the keypad when the CAM key (L) is pressed.

4. Enter Display: Shows the number entered on the NUMERIC KEYPAD (E).

Note: Items A through K are multi-function keys. The function available depends upon the operating mode of the keyboard. The first description supplies the primary (Operate) function. The second description provides the Menu mode function. The third description provides the VCR mode function (represented by orange symbols on the keyboard).

A. OFF/Page Left key/ Stop: Turns off auxiliary device in Monitor Operate mode. Displays page to left in Menu mode. Stops VCR in VCR Operate mode.

B. ON/Page Right key/Record: Turns on auxiliary device in Monitor Operate mode. Displays page to right in Menu mode. Starts VCR recording in VCR Operate mode.

C. PRESET/Enter key: Calls presets in Operate mode. Sets presets in Program mode. Stores entered menu data.

D. PATRN/Exit key: Runs and repeats patterns in Operate mode. Sets patterns in Program mode. Exits Menu mode.

E. CLOSE/Page Up key/ Pause: Closes camera iris in Operate mode. Displays prior menu page up in Menu mode. Pauses VCR in VCR Operate mode.

F. OPEN/Page Down key/ Play: Opens camera iris in Monitor Operate mode. Displays next menu page down in Menu mode. Plays VCR in VCR Operate mode.

G. Joystick: Enables the user to pan, tilt, zoom and flip the camera under keyboard control.

H. FAR/Right Arrow / Fast Forward key: Adjusts focus of distant objects in Monitor Operate mode. Moves cursor right one character in Menu mode. Fast Forwards VCR in VCR Operate mode.

I. NEAR/Left Arrow key/ Rewind: Adjusts focus of near objects in Monitor Operate mode. Moves cursor left one character in Menu mode. Rewinds VCR in VCR Operate mode.

1 2 3 4 A B C

D

E

F

G

HI J K L MNOP Q R S T U

V

W

X

Y

Z

Page 5: Using MegaPower 168 Matrix Switcher with AD2088 Keyboard …americandynamics.net/WebApps/getDocument.aspx?filename=8200-0170... · MEGAPOWER 168 / AD2088 OPERATION AND PROGRAMMING

MEGAPOWER 168 / AD2088 OPERATION AND PROGRAMMING REFERENCE GUIDE (8200-0170-01, REV. A)

5 of 30

J. ACK key /Down Arrow /Eject key: Acknowledges alarms, runs tours, sets and repeats patterns in Operate mode. Moves cursor down one row in Menu mode. Ejects tape in VCR Operate mode.

K. VCR/Up Arrow key: Enables selection of VCR Operate mode. Moves cursor up one row in Menu mode.

L. CAM (Camera) key: Calls the camera number entered using the numeric keypad.

M. Numeric Keypad: Keys ranging from 0 to 9 that enable the user to select specific cameras, monitors, salvos, tours, presets, patterns, auxiliaries, recorders, sites, and macros.

N. MON (Monitor) key: Calls the monitor number entered using the numeric keypad.

O. CLEAR key: Removes numbers entered on the numeric keypad.

P. MACRO keys: Eight macro keys are provided to call specified macros whose number is entered on the numeric keypad.

Q. NEXT key: Calls the next camera displayed in a sequence (tour).

R. LAST key: Calls the prior camera displayed in a sequence (tour).

S. SALVO key: Calls a specified salvo whose number is entered on the numeric keypad.

T. HOLD key: Holds the current camera in a sequence (tour).

U. RUN key: Runs system and scratch pad tours.

V. Keyswitch: Enables the user to switch to the Operate, Program, or Menu modes of operation. When the keyswitch is set to Menu position, the page and cursor navigation functions of the multi-function keys are activated.

W. PROG key: Enables the user to set scratch-pad tours and patterns, as well as a number of other switching system functions.

Y, Z. F1 & F2 keys: Special functions keys used to implement basic system commands and SpeedDome/DeltaDome control.

General User Tasks The following tasks can be performed regardless of the keyswitch setting.

• Log On

• Log Off

• Select Monitor or VCR mode

Logging On If UC appears in the Camera display of your keyboard, User Codes and Passcodes have been implemented at your facility. You must log on before attempting to use the system.

1. UC (User Code) appears in the Camera display.

CAMERA

2. Use the numeric keypad to enter the User Code

(1-64). Press Ack. 3. PSC (Passcode) appears in the Camera display.

CAMERA

4. Use the numeric keypad to enter the passcode

(up to 6 digits). Press Ack.

Once logged on, you can begin performing other tasks.

Page 6: Using MegaPower 168 Matrix Switcher with AD2088 Keyboard …americandynamics.net/WebApps/getDocument.aspx?filename=8200-0170... · MEGAPOWER 168 / AD2088 OPERATION AND PROGRAMMING

MEGAPOWER 168 / AD2088 OPERATION AND PROGRAMMING REFERENCE GUIDE (8200-0170-01, REV. A)

6 of 30

Logging Off When the AD168 system is not in use, you should log off the system. This will ensure that unauthorized users cannot control your system.

1. Use the numeric keypad to enter 99.

2. Press the F1 key (located below the Site display).

SITE

F1 F2

3. UC (User Code) appears in the Camera display to indicate successful log off.

Selecting Monitor or VCR Mode The AD2088 keyboard may be operated in one of two modes: Monitor Control or VCR Control. The current mode of operation is indicated by a dash appearing on the Monitor/VCR display.

If the dash is positioned directly beneath the display’s monitor label, the unit is in Monitor mode.

MONITOR

VCR If the dash is positioned directly above the display’s VCR label, the unit is in VCR mode.

MONITOR

VCR

• Press the VCR key to select VCR mode.

• Press the MON key to select Monitor mode.

Note: If a Monitor or VCR number is not entered prior to pressing either the VCR or MON keys, the keyboard recalls last VCR or monitor number selected prior to toggling to the alternate mode.

Working in Operate Mode

OPERATE

MENU

When the keyswitch is in the Operate position, the following AD168 tasks can be performed.

Table 1: Operate Mode Tasks

If you want to… See page

Select Monitor 7

Select Cameras/Domes 7

Lock Cameras/Domes 7

Control Cameras/Domes 8

Call Presets 9

Run Pattern 9

Run Tour 10

Run Macros 10

Control Auxiliary 11

Control VCRs 11

Acknowledge Alarms 12

Run Salvos 12

Enter 99 then press F1 to log off.

Monitor mode is active.

VCR mode is active.

Page 7: Using MegaPower 168 Matrix Switcher with AD2088 Keyboard …americandynamics.net/WebApps/getDocument.aspx?filename=8200-0170... · MEGAPOWER 168 / AD2088 OPERATION AND PROGRAMMING

MEGAPOWER 168 / AD2088 OPERATION AND PROGRAMMING REFERENCE GUIDE (8200-0170-01, REV. A)

7 of 30

Selecting Monitors Workstation monitors display the video from the cameras and domes installed in local and/or satellite facilities. Each monitor has an identification number assigned by the system administrator. Up to 12 monitors can be installed in a single bay AD168 system. Up to 24 monitors can be installed in a dual bay system.

Note: Verify that the keyswitch is in the Operate position before performing this task.

1. Use the numeric keypad to enter the monitor identification number. The numbers appear in the ENTER display.

2. Press the MON key. The monitor identification number appears in the MONITOR/VCR display window. The ENTER display clears.

MONITOR

VCR The selected monitor is under keyboard control. Camera video can now be viewed on the called monitor.

Selecting Cameras and Domes Once a monitor is selected, you may call camera or dome video to the monitor. Each system camera has a unique identification number documented by the system administrator.

Note: Verify that the keyswitch is in the Operate position before performing this task.

1. Use the numeric keypad to enter the camera identification number. The number appears in the ENTER display.

2. Press the CAM key. The number clears from the ENTER display, and appears in the CAMERA display.

CAMERA

The selected video input now appears on the monitor screen. Depending upon the camera type, you may be able to control the pan, tilt, zoom, focus, and iris settings.

Locking Cameras and Domes Cameras can be “locked” to prevent other keyboard operators from controlling their movements. If a camera is locked, other operators with the same or lower priority will be able to view the camera, but will not be able to control its pan, tilt, zoom, focus, iris, preset, and auxiliary functions. When an operator calls a camera that has been locked out, the word “LOCK” appears on the monitor’s status line. An operator with a higher priority level than the operator who locked the camera can gain control of the camera. The F1 key (located below the Site display) is used to lock or unlock the selected camera.

Figure 4: F1 function key

SITE

F1 F2

Note: Verify that the keyswitch is in the Operate position before performing this task. To lock or unlock control access to a camera: 1. Call or hold the desired camera on the monitor

under your keyboard control 2. Enter either of the following F1 code

combinations: • “2 F1” locks the camera • “1 F1” unlocks the camera

Enter 2, pressF1 to lock. Enter 1, pressF1 to unlock.

Page 8: Using MegaPower 168 Matrix Switcher with AD2088 Keyboard …americandynamics.net/WebApps/getDocument.aspx?filename=8200-0170... · MEGAPOWER 168 / AD2088 OPERATION AND PROGRAMMING

MEGAPOWER 168 / AD2088 OPERATION AND PROGRAMMING REFERENCE GUIDE (8200-0170-01, REV. A)

8 of 30

Controlling Cameras and Domes With the AD2088 keyboard, you can control the pan, tilt, zoom, focus and iris settings for appropriately equipped cameras.

Note: Verify that the keyswitch is in the Operate position before performing this task.

Using the Joystick The joystick—located on the lower right corner of the keyboard—controls the panning and tilting of cameras connected to the switching system. In addition, the twisting the control adjusts the zoom setting, and pressing the button on top of the joystick enables the “flip” function for rotating domes 180° (if supported by the dome).

Figure 5: AD2088 Joystick

Pan/Tilt Control

To control pan/tilt direction:

• Move the joystick left or right for pan control.

• Move the joystick towards you (down) or away from you (up) for tilt control.

Note: For cameras with variable speed pan/tilt capability, camera movement speed is proportional to the positioning of the joystick. The further from the stationary center position the joystick travels, the faster the camera moves. Eight independent speed levels are available for the up, down, left, and right directions.

When the camera has been positioned appropriately, release the joystick to the center position.

Controlling Zoom

Twisting the control knob on the joystick controls the zoom setting.

• To zoom in (increase magnification), twist the knob to the right (labeled TELE).

• To zoom out (decrease magnification), twist the knob to the left (labeled WIDE).

Flipping Domes To “flip” the dome under keyboard control 180° from its current position (for uninterrupted surveillance of subjects who pass directly beneath the camera, press the button on the top of the joystick knob.

Note: On suitably equipped domes with the auto-flip function turned enabled, the dome flips automatically when the Tracker Ball is held in the tilt down position and the dome reaches its lower limit.

Adjusting Focus and Iris Settings

The camera focus and iris control keys are located to the right of the numeric keypad.

Figure 6: Iris and Focus keys

FAR

FOCUS

OPEN

IRIS

Focus refers to the action of adjusting the clarity of the camera image displayed on the monitor. Use the Focus Control keys to adjust the focus setting.

• Press the FAR key to focus the camera on a distant object.

• Press the NEAR key to focus on a closer object.

Normally, the brightness of a picture is controlled by the camera's auto gain and the auto/manual iris functions. The Iris Control keys allow you to manually adjust the brightness or darkness of an image.

• Press the iris OPEN key to brighten the image.

• Press the iris CLOSE key to darken the image.

Note: SpeedDome Ultra dome units are designed with Auto Focus and Auto Iris capability. After performing manual focus or iris adjustments, the auto control mode may be resumed by pressing the iris OPEN and CLOSE keys simultaneously.

Move up, down, left, or right for Pan/Tilt control.

Twist for zoom control.

Press for dome flip.

Page 9: Using MegaPower 168 Matrix Switcher with AD2088 Keyboard …americandynamics.net/WebApps/getDocument.aspx?filename=8200-0170... · MEGAPOWER 168 / AD2088 OPERATION AND PROGRAMMING

MEGAPOWER 168 / AD2088 OPERATION AND PROGRAMMING REFERENCE GUIDE (8200-0170-01, REV. A)

9 of 30

Calling Presets A preset is a memorized location or scene that a pan/tilt camera or dome can display on demand. Presets are also referred to as shots or targets. The Preset key is located in the upper-right corner of the keyboard.

Figure 7: Preset and Pattern keys CONTROL

PRESET

Note: Verify that the keyswitch is in the Operate position before performing this task.

To call a preset: 1. Call the camera or dome that will display the

preset.

2. Use the numeric keypad to enter the preset identification number.

3. Press the PRESET key.

The selected scene now appears on the monitor with appropriate pan, tilt, zoom, and focus adjustments.

Running Patterns A pattern is a sequential series of pan, tilt, zoom, and focus commands defined for SpeedDome series domes, and are programmed in real time. The Pattern (PATRN) key is located in the upper-right corner of the keyboard.

Note: Verify that the keyswitch is in the Operate position before performing these tasks.

To run a pattern one time: 1. Call the dome that will run the pattern.

2. Use the numeric keypad to enter the pattern number (1-3).

3. Press the PATRN key located in the upper right corner of the keyboard. P-1, P-2, or P-3 appears in the ENTER display.

4. Press the RUN key located below the Monitor/VCR display. The camera runs through the pattern movements once.

Note: If the selected pattern has not been programmed, the default “Apple Peel” pattern runs.

To repeat a pattern: 1. Call the dome that will run the pattern.

2. Use the numeric keypad to enter the pattern number (1-3).

3. Press the PATRN key located in the upper right corner of the keyboard. P-1, P-2, or P-3 appears in the ENTER display.

4. Press the ACK key located to the left of the joystick.

The pattern will run repeatedly until a camera command (pan, tilt, zoom, focus or iris) is issued.

Holding Patterns 1. Call the dome that will run the pattern.

2. Use the numeric keypad to enter the pattern number (1-3).

3. Press the PATRN key located in the upper right corner of the keyboard. P-1, P-2, or P-3 appears in the ENTER display.

4. Press the HOLD key located below the Monitor/VCR display. The camera moves to the start of the selected pattern and holds until the RUN or ACK key is pressed.

Patterns and Older SpeedDome Camera Domes If you cannot get patterns to work with older series SpeedDome camera domes, try using the function keys to access the patterns.

Note: Verify that the keyswitch is in the Operate position before performing this task.

The following table lists the pattern function key commands.

Table 2: Pattern Function Keys

If you want to … Press the following keys…

Run Pattern 1 21-F1

Run Pattern 2 22-F1

Run Pattern 3 23-F1

Repeat Pattern 1 41-F1

Repeat Pattern 2 42-F1

Repeat Pattern 3 43-F1

Preset Pattern

Page 10: Using MegaPower 168 Matrix Switcher with AD2088 Keyboard …americandynamics.net/WebApps/getDocument.aspx?filename=8200-0170... · MEGAPOWER 168 / AD2088 OPERATION AND PROGRAMMING

MEGAPOWER 168 / AD2088 OPERATION AND PROGRAMMING REFERENCE GUIDE (8200-0170-01, REV. A)

10 of 30

If you want to … Press the following keys…

Go to (hold) Pattern 1 31-F1

Go to (hold) Pattern 2 32-F1

Go to (hold) Pattern 3 33-F1

Controlling Tours A tour is a dynamic sequence of camera views or patterns, each of which appears on a selected monitor screen for a specified dwell time. In addition, each preset or pattern can have a pre-programmed preset status, auxiliary status, and connect next designation. The tour control buttons are located below the Monitor/VCR display.

Figure 8: Tour control keys

RUN

MONITOR

VCR

LAST NEXT

Additionally, there are monitor or "scratch-pad" tours, which are temporary tours programmed for the operator's currently selected monitor.

Note: Verify that the keyswitch is in the Operate position before performing these tasks.

Running System Tours

1. Select the monitor where the tour will run.

2. Use the numeric keypad to enter the system tour number to be associated with the monitor under control.

3. Press the RUN key, and then press the ACK key within three seconds to run the designated system tour.

Note: Tour direction can be changed while a tour is in progress. To change the direction of a running tour, press the NEXT or LAST key, depending on which is appropriate in a given situation.

Holding Tours

A tour can be stopped and held on a single camera entry by pressing the HOLD key. While a tour is on hold, all keyboard control actions (pan, tilt, lens adjustment, and auxiliary on/off functions) can be performed on the held camera. You may also step forward and backward through the cameras in the tour by pressing NEXT or LAST.

Re-Starting Tours

• To re-start a held tour in the forward direction, Press the RUN key.

• To re-start a tour in the reverse direction, press the LAST key, followed by the RUN key.

Running Macros A macro is a sequence of up to 21 keystrokes that is executed by typing the macro’s numeric identifier (up to four digits), and pressing the designated macro key. A macro can be made up of all Monitor mode inputs, all VCR mode inputs, or a combination of both.

Eight macro keys are available. These are located below the Camera display.

Figure 9: Macro keys

SLOTS

CAMERA

Industry-specific and general-purpose labels are included with the keyboard. The labels shown in Figure 9 are examples of those included for the gaming industry.

Note: Verify that the keyswitch is in the Operate position before performing this task.

To run a macro: 1. Use the numeric keypad to enter the macro

number.

2. Press the appropriate macro key.

StartsTour

Displaysprevious

scene

Pauses Tour

Displays subsequent scene

Page 11: Using MegaPower 168 Matrix Switcher with AD2088 Keyboard …americandynamics.net/WebApps/getDocument.aspx?filename=8200-0170... · MEGAPOWER 168 / AD2088 OPERATION AND PROGRAMMING

MEGAPOWER 168 / AD2088 OPERATION AND PROGRAMMING REFERENCE GUIDE (8200-0170-01, REV. A)

11 of 30

Controlling Auxiliary Devices An auxiliary is a relay that controls devices such as lights, door locks, and audible alarms. Auxiliary devices are also called output devices. Use the Auxiliary ON and OFF keys (located to the right of the Enter display) to control the devices.

Figure 10: Auxiliary Control keys

ONOFF

ENTER

Auxiliary devices may be momentary or latched. A momentary auxiliary remains active as long as its control key is pressed. An example of momentary auxiliary action is a door that remains unlocked as long the auxiliary ON key is pressed. When the key is released, the door returns to its locked state.

A latched auxiliary remains active until it is deactivated using the appropriate off switch. An example of a latched auxiliary is a light. When the auxiliary ON key is pressed (and released), the light is turned on. When the auxiliary OFF key is pressed (and released), the light is turned off.

IMPORTANT! The number of available auxiliaries depends on the dome type. Outdoor SpeedDomes have only one auxiliary connection. Indoor SpeedDomes have four auxiliary connections. If you are unsure about the number of available outputs on the device, refer to your operator’s manual.

Note: Verify that the keyswitch is in the Operate position before performing this task.

To activate an auxiliary: 1. Call the camera associated with the appropriate

relay.

2. Use the numeric keypad to enter the auxiliary number (1-4).

3. Press the AUXILIARY ON key.

Note: When the ON key is released, a latched auxiliary remains activated. A momentary auxiliary is deactivated.

4. To de-activate a latched relay, press the AUXILIARY OFF key.

Controlling VCRs Note: To use this function, you must purchase and install optional VCR interfaces.

If VCRs are connected to the AD168 system, you may control recording and playback of videotapes with the AD2088 keyboard. The VCR control keys are part of the dual function keys located to the right of the numeric keypad and ENTER display.

Figure 11: VCR control keys

VCR ACK

TASK

FAR

FOCUS

OPEN

IRIS

ONOFF

Note: Verify that the keyswitch is in the Operate position before performing this task.

To control a VCR: 1. Enter the VCR number (up to four digits).

2. Press the VCR key.

When VCR mode is selected, the multi-function keys (labeled “auxiliary”, “iris”, “focus”, and “task”) switch to their VCR functions (Play, Record, Eject, Pause, Stop, Fast Forward, and Rewind).

3. Select a VCR function by pressing the appropriate key.

To return to the monitor mode of operation, press the MON key. The switching system remembers the number of the last monitor selected prior to toggling the mode.

Stop

Pause

Rewind

VCRmode

Record

Play

Fast Forward

Eject

Page 12: Using MegaPower 168 Matrix Switcher with AD2088 Keyboard …americandynamics.net/WebApps/getDocument.aspx?filename=8200-0170... · MEGAPOWER 168 / AD2088 OPERATION AND PROGRAMMING

MEGAPOWER 168 / AD2088 OPERATION AND PROGRAMMING REFERENCE GUIDE (8200-0170-01, REV. A)

12 of 30

Acknowledging Alarms System cameras may be associated with alarm contacts connected to key security points under camera view. If an alarm is activated, the camera scene associated with the alarm appears on a system monitor or monitors that are armed for alarm display. When the alarm camera scene appears on the monitor screen, the word “ALARM” appears on the monitor’s on-screen status line. If an alarm title has been programmed, the alarm title also appears in the alarm title area.

Some system monitors are armed for automatic or delayed automatic clearance. Monitors armed for manual clearance (acknowledgment) can be cleared from a keyboard controller using the ACK key located to the left of the joystick.

Figure 12: Alarm Acknowledge key

ACK

Note: Verify that the keyswitch is in the Operate position before performing these tasks.

Acknowledging Single Alarms

1. Call the monitor that is displaying the alarm video.

2. Press the ACK key.

Acknowledging an Alarm Salvo

1. Call the first (lowest numbered) monitor in the alarm group (salvo).

2. Press the ACK key.

Acknowledging Sequencing Alarms

If a monitor is cycling through a sequence of multiple alarm scenes, do the following:

1. Hold or step to (press NEXT or LAST) the first alarm to be cleared.

2. Press the ACK key.

3. Repeat steps 1 and 2 for each alarm in the sequence until all alarms are cleared.

Acknowledging a Wired Set

A wired set is a set of alarm contacts such that when any one member of the set is activated, all of the members are activated.

To acknowledge the wired set: 1. Call the monitor associated with the alarm

contact.

2. Press ACK.

All alarms in the wired set are cleared when this alarm is cleared.

Running Salvos A salvo is a group of camera scenes that can be called for simultaneous display on a contiguous group of monitors. Up to 64 salvos may be programmed. The Salvo key is located below the Monitor/VCR display beneath the Run and Hold keys.

Figure 13: Salvo key

RUN

MONITOR

VCR

To call a salvo: 1. Enter the number of the first (lowest numbered)

monitor in the salvo group on the numeric keypad.

2. Press the MON (monitor) key.

3. Use the numeric keypad to enter the salvo number (1-64).

4. Press the SALVO key. The salvo will appear on the appropriate monitor group.

The first monitor of the salvo group displays “HOLD” on the status line. The remaining monitors in the salvo group display “SALVO”.

Note: If a salvo is called in response to a system alarm, the first monitor of the salvo group displays “ALARM” on the status line. The remaining monitors in the alarm salvo group display “SALVO”.

Page 13: Using MegaPower 168 Matrix Switcher with AD2088 Keyboard …americandynamics.net/WebApps/getDocument.aspx?filename=8200-0170... · MEGAPOWER 168 / AD2088 OPERATION AND PROGRAMMING

MEGAPOWER 168 / AD2088 OPERATION AND PROGRAMMING REFERENCE GUIDE (8200-0170-01, REV. A)

13 of 30

Working in Program Mode OPERATE

MENU

When the keyswitch is in the Program position, the following AD168 programming tasks can be performed.

Table 3: Program Mode Tasks

If you want to… See page

Program Patterns 13

Program Presets 14

Program Monitor Tours 14

Arm/Disarm Monitors 15

Program Macros 17

In addition, the following system settings can be configured via the keyboard.

Table 4: Program Mode System Setup Tasks

If you want to… See page

Reset the system 17

Set the date format 17

Arrange Monitor Text Display 17

Adjust Monitor Text Position 18

Detect Camera Video Loss 18

Program Audio Alarms 19

Pattern Programming You can program up to three patterns per SpeedDome programmable dome. The length and complexity of a pattern are limited by two variables:

• The number of available camera commands

• Time

Each time you move the camera in any direction (with zoom, focus, or iris adjustments), you issue a command to the camera. The three patterns for a dome can collectively consist of up to 98 camera commands.

There is also a pattern time limit. A single pattern cannot have a duration longer than 400 seconds. Regardless of the number of commands issued, a pattern stops recording once the time limit has elapsed.

To program a pattern: 1. Select the camera where the pattern will be

saved.

2. Turn the keyswitch to the PROGRAM position.

3. Use the numeric keypad to enter the pattern number (1-3).

4. Press the PATRN key. Depending upon the pattern number entered, the ENTER display will show “P-1”, “P-2”, or “P-3”.

IMPORTANT! With SpeedDome Ultra series domes, a progress bar displays showing the remaining number of programming steps available. The progress bar decreases as the pattern commands are used. In addition, the dome moves very slowly during patterns and cannot be adjusted.

5. Press the PROG key. Using the joystick and lens keys, maneuver the called camera to define the pattern.

6. When finished programming the pattern, press the ACK key to save.

Page 14: Using MegaPower 168 Matrix Switcher with AD2088 Keyboard …americandynamics.net/WebApps/getDocument.aspx?filename=8200-0170... · MEGAPOWER 168 / AD2088 OPERATION AND PROGRAMMING

MEGAPOWER 168 / AD2088 OPERATION AND PROGRAMMING REFERENCE GUIDE (8200-0170-01, REV. A)

14 of 30

Pattern Programming for Older SpeedDome Series Domes

If you have older SpeedDome series domes installed at your facility, use the following procedure.

1. Select the camera that will be used for programming the pattern.

2. Turn the keyswitch to the PROGRAM position.

3. Do one of the following:

Pattern Number Function Key Command

Pattern 1 121 F2

Pattern 2 122 F2

Pattern 3 123 F2

4. Using the joystick and lens keys, maneuver the called camera to define the pattern.

5. Enter 120 and press the F2 key to end the pattern definition.

6. Enter 130 and press the F2 key to save the pattern to memory.

Programming Preset Scenes Certain cameras with pan/tilt and motorized lens capability can be programmed to immediately move to specific pan, tilt, zoom, and focus positions when called by a keyboard.

Note: The number of available presets depends upon the PTZ or dome type. Refer to the PTZ or dome documentation for additional information. The maximum number of SensorNet or RS-422 dome presets is limited to 72 because the presets are stored in the AD168, not the dome.

To program a preset scene for later recall: 1. Select the camera where the preset will be

saved.

2. Turn the keyswitch to the PROGRAM position.

3. Using the joystick, move the camera to the appropriate position. Make the necessary lens adjustments.

4. Use the numeric keypad to enter the preset number (1-72 depending upon PTZ/dome type).

5. Press the PRESET key.

Programming Monitor Tours A monitor (“scratch pad") tour is a temporary sequence of camera views programmed for the monitor under keyboard control. A monitor tour can contain up to 64 camera scenes sequenced in any order. Each scene is shown for a specified duration called the dwell time.

To program a monitor tour: 1. Select the monitor on which the tour will be

displayed.

2. Turn the keyswitch to the PROGRAM position.

3. Use the numeric keypad to enter 62. Press the PROG key (located above the keyswitch) to clear any previously programmed monitor tour.

4. Enter the first camera number to include in the tour, and press the CAMERA key.

5. Enter the dwell time (1-60) on the numeric keypad. Press the PROG key.

6. Repeat steps 4 and 5 until all the cameras in the tour have been programmed. When finished, continue with step 7.

7. Press either the HOLD key or the RUN key to exit the monitor tour programming mode.

• The HOLD key leaves the tour on hold, and displays the last camera scene selected.

• The RUN key switches the video to the first camera in the tour and initiates the tour sequence.

Monitor Tour Programming Options

When a tour is running, press the HOLD key to stop the tour and hold the currently displayed camera. While the tour is on hold, it can be re-programmed in the following ways.

Adding a Camera to a Tour 1. Press the NEXT key until the desired camera

scene is displayed, then press the HOLD key.

2. Turn the keyswitch to the PROGRAM position.

3. Call the camera to be inserted in the tour.

4. Enter the desired dwell time (1-60).

5. Press the PROG key to set the dwell time.

6. Press the HOLD or RUN key to exit the tour programming mode.

Page 15: Using MegaPower 168 Matrix Switcher with AD2088 Keyboard …americandynamics.net/WebApps/getDocument.aspx?filename=8200-0170... · MEGAPOWER 168 / AD2088 OPERATION AND PROGRAMMING

MEGAPOWER 168 / AD2088 OPERATION AND PROGRAMMING REFERENCE GUIDE (8200-0170-01, REV. A)

15 of 30

Removing a Camera from a Tour 1. Press the NEXT key until the desired camera

scene is displayed, then press the HOLD key.

2. Turn the keyswitch to the PROG position.

3. Enter “0” on the numeric keypad, and press the PROG key to erase the currently displayed tour entry.

4. Press the HOLD or RUN key to exit the tour programming mode.

Changing the Dwell Time for a Tour Entry 1. Press the NEXT key until the desired camera

scene is displayed, then press the HOLD key.

2. Turn the keyswitch to the PROGRAM position.

3. Enter 0 on the numeric keypad to erase the current dwell time.

4. Enter the new dwell time (1-60) on the numeric keypad.

5. Press the PROG key to set the new dwell time.

6. Press the HOLD or RUN key to exit the tour programming mode.

Monitor Arming Armed monitors are system monitors that are configured to display alarm signals as they occur. By arming a monitor, you define how it will display, queue, and clear incoming alarms. Before arming a monitor, you must understand the alarm display, queue, and clearance methods.

Alarm Display Methods

There are three alarm display methods:

Single Display: Incoming alarms are displayed on a single monitor. Multiple alarms received at a single monitor will be displayed in sequence based on the monitor’s queuing method.

Dual Display: Incoming alarms are displayed on a pair of monitors. The hold monitor receives the first of a series of alarms. The sequence monitor receives subsequent and queues the incoming alarms. After an alarm is cleared on the hold monitor, the first alarm in queue on the sequence monitor is moved to the hold monitor for viewing and clearance.

Block Display: Incoming alarms are displayed on a group (block) of monitors. The first incoming alarm is displayed on the first (lowest numbered) monitor of the block. The second alarm is displayed on the next lowest numbered monitor of the block, and so on. When all monitors in a given block are displaying alarm video signals, all subsequent alarms are held in queue until displayed alarms are cleared.

Alarm Queuing Methods

There are two alarm queuing methods:

Sequence Queuing: Incoming alarms are displayed in sequence at an armed monitor, and cycle continuously until each is cleared. Each alarm will be displayed for a pre-programmed dwell time, before it is succeeded by the next received alarm.

Hold Queuing: An incoming alarm is displayed and held on an armed monitor until it is cleared. All subsequent alarms are queued in order until the current held alarm is cleared.

Alarm Clearance Methods

There are three alarm clearance methods:

Manual Clear: An alarm is cleared by pressing the Ack key.

Instant Clear: An alarm is reset immediately at its source (if the alarm has not already been manually acknowledged). For example, a door opens and activates an alarm. Closing the door clears the alarm instantly.

Auto Clear: An alarm is reset at its source after a 20 second delay (if the alarm has not already been manually acknowledged). For example, a door opens and activates an alarm. The door is immediately closed, but the alarm will not clear unless the door remains closed for a 20 second interval.

Monitor Arming Codes

Arming codes are derived from the different combinations of display, queuing, and clearance methods. Based on the combinations, there are 16 codes, each with its own number and a three or four letter acronym ID. The default arming code for all monitors is DIS (disarmed).

Note: Monitor blocks must be defined through S³ software.

Page 16: Using MegaPower 168 Matrix Switcher with AD2088 Keyboard …americandynamics.net/WebApps/getDocument.aspx?filename=8200-0170... · MEGAPOWER 168 / AD2088 OPERATION AND PROGRAMMING

MEGAPOWER 168 / AD2088 OPERATION AND PROGRAMMING REFERENCE GUIDE (8200-0170-01, REV. A)

16 of 30

Table 5: Monitor Arming Codes

Code # Display / Queuing / Clearance Code

1 Single / Sequence / Instant SSI

2 Single / Sequence / Auto SSA

3 Single / Sequence / Manual SSM A

4 Single / Hold / Instant SHI

5 Single / Hold / Auto SHA

6 Single / Hold / Manual SHM A

7 Block / Sequence / Instant BSI

8 Block / Sequence / Auto BSA

9 Block / Sequence / Manual BSM A

10 Block / Hold / Instant BHI

11 Block / Hold / Auto BHA

12 Block / Hold / Manual BHM A

13 (h) Dual / Hold / Instant DHI

13 (s) Dual / Sequence / Instant DSI

14 (h) Dual / Hold / Auto DHA

14 (s) Dual / Sequence / Auto DSA

15 (h) Dual / Hold / Manual DHM A

15 (s) Dual / Sequence / Manual DSM A

16 Disarm Monitor DIS

Note: If a dual display code [13-15] is selected, the second (sequence) monitor is automatically selected after the first (hold) monitor is armed. The sequence monitor number will always equal the hold monitor number + 1.

To arm a monitor: 1. Call the monitor to be armed.

2. Turn the keyswitch to the PROGRAM position.

3. Select the desired arming code from the table above, and enter the code number (1-15) on the numeric keypad.

4. Press the ARM key in the keyboard’s MONITOR section. The code letters will be displayed for five seconds in the on-screen status line.

Note: Monitor arming can be verified at any time, by pressing the ARM key. The arming code letters will be displayed for five seconds in the status line. If the monitor is not armed the code “DIS” will be displayed.

Option for Manual Clearance

Any monitor assigned for instant or auto clearance can be additionally enabled for manual clearance.

To enable or disable manual clearance: 1. Call the desired armed monitor.

2. Turn the keyswitch to the PROGRAM position.

3. Do one of the following:

Command Function

17 ARM Enable manual clearance

18 ARM Disable manual clearance

4. Press the ARM key.

Any monitor armed for manual clearance will display a four-letter code acronym with “A” (acknowledge) as its fourth or right-most code letter.

Disarming a Monitor

1. Clear all currently active alarms.

2. Call a currently armed monitor.

3. Turn the keyswitch to the PROGRAM position.

4. Enter 316 and press F2 to disarm the monitor.

Page 17: Using MegaPower 168 Matrix Switcher with AD2088 Keyboard …americandynamics.net/WebApps/getDocument.aspx?filename=8200-0170... · MEGAPOWER 168 / AD2088 OPERATION AND PROGRAMMING

MEGAPOWER 168 / AD2088 OPERATION AND PROGRAMMING REFERENCE GUIDE (8200-0170-01, REV. A)

17 of 30

Programming Macros There are eight keys on the AD2088 keyboard used for macros. A macro can consist of up to 21 keystrokes. Up to a 1000 different macros can be divided among the eight keys.

Note: Each macro key can have multiple switching sequences and therefore multiple numbers associated with the key. The maximum number of switching sequences that can be assigned to the eight macro keys = 1000. Numbering for each key can start at “1”, however, it is not necessary to assign numbers in exact sequence.

To program a macro: 1. Turn the keyswitch to the PROGRAM position.

2. Enter the macro number (1-1000).

3. Press the macro key to be programmed.

The macro number appears in the CAMERA display and a keystroke counter starting at 21 appears in the MONITOR/VCR display.

4. Enter the keystrokes that comprise the macro. As you press keys, the keystroke counter decreases.

5. When finished entering the macro keystrokes, press the macro key to save.

IMPORTANT! You must press the same macro key you selected in step 3 to save the macro.

Resetting the System

WARNING: Resetting the AD168 clears all programmed information about the system. Before performing this task, backup your settings using the S3 software.

To clear all previously programmed information, and reset the system to its original default settings, perform a system reset.

1. Turn the keyswitch to the PROGRAM position.

2. Enter 55 and press F2.

3. Enter 99 and press F2.

Note: Step 3 must be performed within 3 seconds of performing step 2 or the reset will not occur.

Setting the Date Format Note: This procedure may also be performed through the menus. See Changing Time and Date Settings on page 23.

There are three options for the on-screen date format:

• Month, date year (MM-DD-YY)

• Date, month, year (DD-MM-YY)

• Year month, date (YY-MM-DD)

To set the date format from the keyboard: 1. Turn the keyswitch to the PROG position

2. Enter one of the following F2 code combinations:

• Enter 21, and then press F2 for MM-DD-YY.

• Enter 22, and then press F2 for DD-MM-YY.

• Enter 23, and then press F2 for YY-MM-DD.

• Enter 24, and then press F2 toggles through the date formats

Note: The default date display format is MM-DD-YY.

Text Display Arrangement Titles, date, and time can be added to, or removed from displaying on-screen. The default display arrangement has titles, date, and time positioned at the bottom of the screen.

To change the monitor display arrangement: 1. Select the monitor where you want to change the

text display arrangement.

2. Turn the keyswitch to the PROGRAM position.

3. Enter one of the following F2 code combinations.

Table 6: Text Display F2 codes

Code Function

1 - F2 Display the time and date on the monitor.

2 - F2 Remove the time and date display.

3 - F2 Display the camera number, title, and status line.

4 - F2 Remove camera title, number, and status line.

5 - F2 Move titles, date, and time to top of display location.

6 - F2 Move titles, date, and time to home location.

7 - F2 Display all titles, date, and time.

8 - F2 Remove all titles, date, and time displays.

!

Page 18: Using MegaPower 168 Matrix Switcher with AD2088 Keyboard …americandynamics.net/WebApps/getDocument.aspx?filename=8200-0170... · MEGAPOWER 168 / AD2088 OPERATION AND PROGRAMMING

MEGAPOWER 168 / AD2088 OPERATION AND PROGRAMMING REFERENCE GUIDE (8200-0170-01, REV. A)

18 of 30

Adjusting Text Display Position To adjust the home positioning of the selected text overlay:

1. Select the monitor where you want to adjust the text display home position.

2. Turn the keyswitch to the PROGRAM position

3. Enter 50, and then press F2 on the keyboard. This enables the joystick for text positioning to the "home" position.

4. Move the keyboard joystick to adjust the positioning of the standard text overlay

5. When the overlay is positioned appropriately, enter 51, and then press F2 on the keyboard. This disables the joystick for text positioning.

6. Turn the keyswitch to the OPERATE position.

Detecting Camera Video Loss The AD168 system has built-in video loss detection. The video loss detection level set for a particular camera is based on the lighting conditions that exist where the camera is installed.

For example:

• A camera installed in a room that is brightly lit on a 24-hour basis would have a video loss detection level set to VIDEO HIGH or VIDEO MED.

• A camera installed in a shadowy or dark area, or an area where lighting conditions vary considerably, would have a video loss detection level set to VIDEO LOW.

Regardless of how the lighting conditions and video signal vary, a sync signal should always be present in a working camera. Setting the video loss detection level for SYNC ONLY produces a video loss message when the sync signal is absent. This would occur if a camera is malfunctioning, disconnected, or if the camera cable is cut.

To set the video loss detection mode: 1. Select or hold the desired camera on the monitor

under your keyboard control.

2. Turn the keyswitch to the PROGRAM position.

3. Enter one of the following F2 code combinations:

Table 7: Video Loss F2 codes

Code Function

100 - F2 Disables video loss detection for the camera.

101 - F2 Enables sync loss detection (SYNC ONLY) for the camera.

102 - F2 Enables sync and low picture content loss detection (VIDEO LOW) for the camera.

103 - F2 Enables sync and medium picture content loss detection (VIDEO MED) for the camera

104 - F2 Enables sync and high picture content loss detection (VIDEO HIGH) for the camera

105 - F2 Enables automatic video loss detection for the camera.

106 - F2 Enables automatic video loss detection for all system cameras.

108 - F2 Clears video loss settings for all cameras

111 - F2 Print the current video loss detection mode of the selected camera.

112 - F2 Prints the current video loss detection mode of all system cameras.

Page 19: Using MegaPower 168 Matrix Switcher with AD2088 Keyboard …americandynamics.net/WebApps/getDocument.aspx?filename=8200-0170... · MEGAPOWER 168 / AD2088 OPERATION AND PROGRAMMING

MEGAPOWER 168 / AD2088 OPERATION AND PROGRAMMING REFERENCE GUIDE (8200-0170-01, REV. A)

19 of 30

Audio Alarm Programming The AD2088 keyboard can be programmed to provide an audio tone when an alarm is received at an armed monitor under keyboard control. The system default setting is audio enabled (ON) for all system keyboards. Audio alarm signals can be enabled or disabled through a keyboard, a keyboard port, or system wide.

Enabling/Disabling Keyboard Port Audio Alarms

To enable/disable an audio alarm for a keyboard port (up to four individual keyboards):

1. Turn the keyswitch to the PROGRAM position. 2. Do one of the following:

Command Function

48 F2 Enables audio alarms for the keyboard port

47 F2 Disables audio alarms for the keyboard port

System Wide Audio Alarm Programming

To enable/disable audio alarm for all keyboard ports:

1. Turn the keyswitch to the PROGRAM position. 2. Do one of the following:

Command Function

46 F2 Enables audio alarms for all keyboard ports

45 F2 Disables audio alarms for all keyboard ports

Page 20: Using MegaPower 168 Matrix Switcher with AD2088 Keyboard …americandynamics.net/WebApps/getDocument.aspx?filename=8200-0170... · MEGAPOWER 168 / AD2088 OPERATION AND PROGRAMMING

MEGAPOWER 168 / AD2088 OPERATION AND PROGRAMMING REFERENCE GUIDE (8200-0170-01, REV. A)

20 of 30

Working in Menu Mode OPERATE

MENU

When the keyswitch is in the MENU position, you are able to view the system menus of the AD168 matrix switcher. These menus provide programming for a limited set of features.

To view the menus:

• Connect a dedicated monitor to the Program Monitor (PROG MON) output located on the AD168 back panel.

OR

• Connect a camera input to the PROG MON output on the AD168 back panel.

IMPORTANT! If the PROG MON is connected to a video input and the MENU CALLUP option has not been set, first call the corresponding video input to the monitor, then turn the keyswitch to MENU.

After the MENU CALLUP option is set, the menus automatically display on the selected monitor whenever the keyswitch is turned to the MENU position.

Once the menu is displayed, the appropriate functions on the multi-function keys are used for operating the menus.

Note: The menu functions are printed on the front of the multi-function keys.

Table 8: Multi-Function keys description

Menu Function

Key label Description

Page Left Auxiliary Off

Displays the menu page to the left.

Page Right Auxiliary On

Displays the menu page to the right.

Page Up Iris Close Displays prior menu page up.

Page Down Iris Open Displays next menu page down.

Left Arrow ←←←←

Focus Near

Moves cursor left one character.

Right Arrow →→→→

Focus Far Moves cursor right one character.

Menu Function

Key label Description

Up Arrow ↑↑↑↑

VCR Moves cursor up one row.

Down Arrow ↓↓↓↓

ACK Moves cursor down one row.

Enter Preset Displays options for a setting, and stores data entered via the menu.

Exit Patrn Exits the current screen and returns to the previously displayed screen.

Note: The joystick may also be used to change the cursor position.

Figure 14: Multi-Function keys CONTROL

PRESET

VCR ACK

TASK

FAR

FOCUS

OPEN

IRIS

ONOFF

IMPORTANT! To store data in MENU mode, the ENTER (Preset) key must be pressed to end the sequence. System keyboards used prior to the release of the AD2088 also allowed use of the ACK key to store data. The ACK key does not function as the save function in the MENU mode on the AD2088 keyboard.

Exiting from the Menu System The user can exit from any menu, or exit from the menu system at any time.

If you want to… Use this…

To return to a prior menu.

Press EXIT (Pattern)

To exit from the menu system.

Turn the keyswitch to the PROGRAM or OPERATE position

Page 21: Using MegaPower 168 Matrix Switcher with AD2088 Keyboard …americandynamics.net/WebApps/getDocument.aspx?filename=8200-0170... · MEGAPOWER 168 / AD2088 OPERATION AND PROGRAMMING

MEGAPOWER 168 / AD2088 OPERATION AND PROGRAMMING REFERENCE GUIDE (8200-0170-01, REV. A)

21 of 30

Using the Main Selection Menu The Main Selection menu provides access to the AD168 features that may be configured using Menu mode.

MAIN SELECTION

1. SYSTEM2. MONITORS3. CAMERAS4. USERS / KEYBOARDS

LANGUAGE ENGLISH

A flashing cursor appears on-screen to indicate the current selection.

The following selections are available:

• Select System to change settings associated with system options, date/time, and port settings.

• Select Monitors to change settings associated with tours, date/time display, and title display.

• Select Cameras to change settings associated with pseudo-numbering, camera titles, and preset titles.

• Select User/Keyboards to changes settings associated with user or keyboard priorities and user passcodes.

Note: The User/Keyboard option changes based on the User IDs setting on the System Options menu.

You can also use this screen to change the language setting for the menus.

To select a menu item:

• Use the Up (VCR) or Down (ACK) keys to move the highlight, and press the Enter (Preset) key.

• Enter the number associated with the menu item, and press the Enter (Preset) key.

• Use the joystick to move the highlight, and press the Enter (Preset) key.

Changing the Language Setting The AD168 menus can be displayed in English, French, German, Spanish, and Portuguese.

To change the language setting: 1. Move the cursor to the Language field.

2. Enter the following key combinations to select the operating language:

Language Command

English 1, Enter (Preset)

French 2, Enter (Preset)

German 3, Enter (Preset)

Spanish 4, Enter (Preset)

Portuguese 5, Enter (Preset)

Following language selection, all menus appear in the selected language.

Changing System Settings The System menu provides the means to define certain system options, the system time and date, and the configuration of each of the AD168 CPU control ports.

SYSTEM

1. SYSTEM OPTIONS2. TIME AND DATE3. PORTS

RETURN MAIN

Use System Options to configure the user login option, programming monitor menu call-up setting, and system display of print messages.

Use Time and Date to set the correct system date and time.

Use Ports to configure RS-232 port parameters, including the device connected, communication baud rate, parity, data bits, and stop bits.

Page 22: Using MegaPower 168 Matrix Switcher with AD2088 Keyboard …americandynamics.net/WebApps/getDocument.aspx?filename=8200-0170... · MEGAPOWER 168 / AD2088 OPERATION AND PROGRAMMING

MEGAPOWER 168 / AD2088 OPERATION AND PROGRAMMING REFERENCE GUIDE (8200-0170-01, REV. A)

22 of 30

Changing System Options When System Options is selected from the System menu, the following menu displays.

SYSTEM OPTIONS

USER IDs - DISABLEDMENU CALLUPMESSAGES TO PROG MONITOR - N

PRINTER MESSAGESALARM - YVIDEO LOSS -YPOWER STATUS - Y

MENU MONITOR - YPREVIOUS MENU

Use this menu to enable or disable User ID passcode login, video input for menu call-up, and printer message display options.

Enabling/Disabling User IDs

The User IDs setting enables or disables the keyboard Passcode Login. The default setting is DISABLED (operator login is not required).

To enable or disable the User IDs setting: 1. Move the cursor to User IDs.

2. Press the Enter (Preset) key to change the setting:

• Select DISABLED if passcode login is not required.

• Select ENABLED if passcode login is required.

3. When finished making changes, press Exit (Patrn) to return to the previous menu.

Note: To take advantage of this setting, User IDs and passcodes must be configured using the Users/Keyboard menu. The setting for User IDs does not take effect until exiting Menu mode.

Configuring Automatic Menu Call-up

The Menu Callup setting identifies which video input is connected to Prog Mon video output. This allows the menus to be displayed automatically on the selected monitor whenever the keyswitch is turned to the MENU position. The default setting is blank (no video input is connected).

To configure the Menu Callup setting: 1. Move the cursor to Menu Callup.

2. Use the numeric keypad to enter the camera number (1-180) of the input that is connected to PROG MON output.

3. Press the Enter (Preset) key to save the camera number.

4. When finished making changes, press Exit (Patrn) to return to the previous menu.

Displaying Messages on the Program Monitor

The Messages to Prog Monitor setting determines if the printer messages relating to alarms, video loss, power status, and menu monitor are displayed on the Program Monitor. The default setting is No.

To display printer messages on the program monitor: 1. Move the cursor to MESSAGES TO PROG

MONITOR.

2. Press the Enter (Preset) key to toggle the settings:

• Select Y (yes) to display printer messages on PROG MON output.

• Select N (no) to disable display of printer messages on the PROG MON output.

3. When finished making changes, press Exit (Patrn) to return to the previous menu.

Page 23: Using MegaPower 168 Matrix Switcher with AD2088 Keyboard …americandynamics.net/WebApps/getDocument.aspx?filename=8200-0170... · MEGAPOWER 168 / AD2088 OPERATION AND PROGRAMMING

MEGAPOWER 168 / AD2088 OPERATION AND PROGRAMMING REFERENCE GUIDE (8200-0170-01, REV. A)

23 of 30

Selecting Printer Messages

The Printer Messages settings select the type of messages output to the printer ports. Four message options are available: Alarm, Video Loss, Power Status, and Menu Monitor. Any or all of these can be enabled for printouts. The default setting is “Yes” for each option.

To select messages types to be printed: 1. Move the cursor to the PRINTER MESSAGES

setting you want to change.

• Alarm for alarm messages

• Video Loss for video loss messages

• Power Status for power on messages

• Menu Monitor for menu access messages

2. Press the Enter (Preset) key to toggle the settings:

• Select Y (yes) to print the selected message type.

• Select N (no) to disable printing of the selected message type.

Note: Appendix C of the AD168 Administrator’s Manual includes the format and content of each message.

3. When finished making changes, press Exit (Patrn) to return to the previous menu.

Changing Time and Date Settings When Time and Date is selected from the System menu, the following menu displays.

TIME AND DATE

DATE FORMAT - MM-DD-YYDATE - 05-25-02TIME - 14:32:00

PREVIOUS MENU

Use this menu to select the date format, change the current date setting, and change the current time setting for the system.

Selecting the Date Format

The Date Format setting selects format for displaying the system date. The format of the Date setting automatically changes to correspond to the format selection. The default format is Month-Day-Year.

1. Move the cursor to the DATE FORMAT line.

2. Press the Enter (Preset) key to scroll through the available date formats.

• Select MM-DD-YY for Month-Day-Year format.

• Select DD-MM-YY for Day-Month-Year format.

• Select YY-MM-DD for Year-Month-Day

3. When finished making changes, press Exit (Patrn) to return to the previous menu.

Note: The date format may also be changed by entering the number that corresponds to the desired format and pressing the Enter (Preset) key.

Number Date Format

1 MM - DD - YY

2 DD - MM - YY

3 YY - MM - DD

Changing the Current Date Setting

The Date setting changes the current system date using the selected format Date Format.

1. Move the cursor to the Date line.

2. Enter the first two digits of the date based on the format selected and press the Enter (Preset) key.

3. Enter the second pair of digits based on the format selected and press the Enter (Preset) key.

4. Enter the third pair of digits based on the format selected and press the Enter (Preset) key.

Note: Pressing the Enter (Preset) key without entering a number results in a “00” entry for that item.

5. When finished making changes, press Exit (Patrn) to return to the previous menu.

Page 24: Using MegaPower 168 Matrix Switcher with AD2088 Keyboard …americandynamics.net/WebApps/getDocument.aspx?filename=8200-0170... · MEGAPOWER 168 / AD2088 OPERATION AND PROGRAMMING

MEGAPOWER 168 / AD2088 OPERATION AND PROGRAMMING REFERENCE GUIDE (8200-0170-01, REV. A)

24 of 30

Changing the Current Time Setting

The Time setting changes the system current date the using HH:MM:SS (hour: minute: second) in 24-hour format.

1. Move the cursor to the Time line.

2. Enter the 2-digit hour (HH) using 24-hour format and press the Enter (Preset) key.

3. Enter the 2-digit minute (MM) and press the Enter (Preset) key.

4. Enter the 2-digit second (SS) and press the Enter (Preset) key.

5. When finished making changes, press Exit (Patrn) to return to the previous menu.

Changing Port Settings When Ports is selected from the System menu, the following menu displays.

PORT - 01

BAUD - 1200DATA BITS - 8PARITY - NONESTOP BITS - 1PORT USE - KEYBOARD

PREVIOUS MENU

Use this menu to configure the baud rate, data bits, parity, stop bits, and port use for each of the eight RS-232 ports.

IMPORTANT! Once the selections for a port have been made, do not change the settings unless the connected devices are changed as well.

Selecting a Port to Configure

1. Move the cursor to the PORT line at the top of the menu.

2. Use the numeric keypad to enter the port number (1-8) you want to configure.

3. Press the Enter (Preset) key. The selected port’s settings are displayed. The default port parameters are shown above.

Once the port is selected, continue with changing the relevant settings.

Changing the Baud Rate

1. Move the cursor to the BAUD setting.

2. Press the Enter (Preset) key to display the available baud rates (300, 1200, 2400, 4800, 9600, 19.2K, or 38.4K).

3. When finished making changes, press Exit (Patrn) to return to the previous menu.

Note: The baud setting may also be changed by entering the number that corresponds to the desired setting and pressing the Enter (Preset) key.

Number Baud Setting

1 300 bps

2 1200 bps

3 2400 bps

4 4800 bps

5 9600 bps

6 19.2K bps

7 38.4K bps

Changing the Data Bits Setting

1. Move the cursor to the Data Bits setting.

2. Press the Enter (Preset) key to change the setting.

Note: You may also enter 7 or 8 using the numeric keypad and press Enter (Preset) to change the setting.

3. When finished making changes, press Exit (Patrn) to return to the previous menu.

Page 25: Using MegaPower 168 Matrix Switcher with AD2088 Keyboard …americandynamics.net/WebApps/getDocument.aspx?filename=8200-0170... · MEGAPOWER 168 / AD2088 OPERATION AND PROGRAMMING

MEGAPOWER 168 / AD2088 OPERATION AND PROGRAMMING REFERENCE GUIDE (8200-0170-01, REV. A)

25 of 30

Changing the Parity Setting

1. Move the cursor to the Parity setting. 2. Press the Enter (Preset) key to cycle through the

parity selections. The choices are None, Odd, and Even.

3. When finished making changes, press Exit (Patrn) to return to the previous menu.

Note: The parity setting may also be changed by entering the number that corresponds to the desired setting and pressing the Enter (Preset) key.

Number Parity Setting

1 None

2 Odd

3 Even

Changing the Stop Bits Setting

1. Move the cursor to the Stop Bits setting. 2. Press the Enter (Preset) key to display the

settings. The available choices are 1 or 2. 3. When finished making changes, press Exit

(Patrn) to return to the previous menu.

Defining Port Use

To define the device type connected the selected RS-232 communications port:

1. Move the cursor to the Port Use setting. 2. Press the Enter (Preset) key to display the port

selections. 3. When finished making changes, press Exit

(Patrn) to return to the previous menu. Note: The port use setting may also be changed by entering the number that corresponds to the desired setting and pressing the Enter (Preset) key.

Number Parity Setting

1 Alarm

2 Keyboard

3 Terminal

4 Printer

5 Aux (auxiliary)

See the Appendix in the AD168 Administrator’s Manual for a listing of the Port Use Types.

Changing Monitor Settings The Monitor menu provides the ability to review and change the setup programming for each monitor.

MONITOR - 001

TOUR --TOUR STATUS - HOLDDATE TIME - ONTITLE DISPLAY - ON

PREVIOUS MENU

Use Tour to assign a system tour to the monitor.

Use Tour Status to display the status of the last tour called to the selected monitor.

Use Date Time to configure whether date and time information is displayed on the monitor.

Use Title Display to configure whether title information appears on the monitor.

Selecting a Monitor to Configure

1. Move the cursor to the MONITOR field at the top of the menu.

2. Use the numeric keypad to enter the monitor number (1-24).

3. Press the Enter (Preset) key.

Once the monitor is selected, continue with changing the relevant settings.

Selecting the System Tour

The Tour setting identifies which System Tour is currently assigned to the selected monitor.

Note: If “_ _” appears in the field, no Monitor Tour is associated with the monitor.

To change the system tour currently assigned to the monitor: 1. Move the cursor to the TOUR setting.

2. Use the numeric keypad to enter the desired System Tour number (1-64).

3. Press the Enter (Preset) key to save the selection and move to the Tour Status entry.

4. When finished making changes, press Exit (Patrn) to return to the previous menu.

Page 26: Using MegaPower 168 Matrix Switcher with AD2088 Keyboard …americandynamics.net/WebApps/getDocument.aspx?filename=8200-0170... · MEGAPOWER 168 / AD2088 OPERATION AND PROGRAMMING

MEGAPOWER 168 / AD2088 OPERATION AND PROGRAMMING REFERENCE GUIDE (8200-0170-01, REV. A)

26 of 30

Changing Tour Status

The Tour Status setting provides the current tour operating status for the selected monitor. The available settings are Hold or Run.

To change the tour status for the monitor: 1. Move the cursor to the Tour Status setting.

2. Press the Enter (Preset) key to change the setting.

• Select HOLD to pause the tour on the current camera.

• Select RUN to start the tour. 3. When finished making changes, press Exit

(Patrn) to return to the previous menu.

Configuring the Display of Date and Time Information

The Date Time setting identifies if date and time display is enabled for the selected monitor.

To change the date/time display for the monitor: 1. Move the cursor to the Date Time field.

2. Press the Enter (Preset) key to change the setting.

• Select ON to enable the display of date/time information.

• Select OFF to disable the display of date/time information.

3. When finished making changes, press Exit (Patrn) to return to the previous menu.

Enabling/Disabling the Title Display

The Title Display setting determines if titles are configured to appear on the selected monitor.

To change the title display for the monitor: 1. Move the cursor to the Title Display setting.

2. Press the Enter (Preset) key to change the setting.

• Select ON to enable title display. • Select OFF to disable title display.

3. When finished making changes, press Exit (Patrn) to return to the previous menu.

Changing Camera Settings The Cameras menu is used to change settings associated with pseudo-numbering, video loss detection, camera titles, and preset titles.

CAMERAS

1. PSEUDO2. TITLES3. PRESET TITLES

RETURN MAIN

Use Pseudo to assign pseudo-numbering to the selected camera.

Use Titles enable video loss detections and assign a 16-character name to the selected camera.

Use Preset Titles to assign a 16-character name to presets for a selected camera.

Assigning Pseudo-Numbering to Cameras

When Pseudo is selected from the Cameras menu, the following menu displays.

ASSIGN PSEUDO CAMERASCAMERAS

REAL # PSEUDO #0001 00010002 00020003 00030004 0004

PREVIOUS MENU

. .

. .0012 0012

Use this menu to assign substitute numbers to cameras. The “real” camera numbers are based on video input connection points. The pseudo numbers permits assignment of any numerical value from 1 to 9999 for any camera input. The Pseudo Number menu has multiple pages, with 12 camera numbers appearing on each page. Use the Page Down (Iris Open) and Page Up (Iris Close) keys to scroll through the list of cameras.

Note: On a system reset, all pseudo numbers are reset to the real (default) camera numbers.

Page 27: Using MegaPower 168 Matrix Switcher with AD2088 Keyboard …americandynamics.net/WebApps/getDocument.aspx?filename=8200-0170... · MEGAPOWER 168 / AD2088 OPERATION AND PROGRAMMING

MEGAPOWER 168 / AD2088 OPERATION AND PROGRAMMING REFERENCE GUIDE (8200-0170-01, REV. A)

27 of 30

IMPORTANT! If a pseudo number change is made through menu programming, it is necessary to upload the change to the PC running S³ in order for the system and PC databases mirror each other.

To assign or change a Pseudo Camera Number: 1. Enter the appropriate REAL # on the numeric

keypad, and press either the PAGE UP (Iris Close) or PAGE DOWN (Iris Open) key.

2. Enter the PSEUDO number (1-9999) to be substituted for the real number.

3. Press the Enter (Preset) key to assign the PSEUDO number.

4. Repeat steps 1 through 3 for each pseudo camera number you want to assign.

5. When finished making changes, press Exit (Patrn) to return to the previous menu.

Changing Camera Titles and Video Loss Settings

When Titles is selected from the Cameras menu, the following menu displays.

CAMERA - 0001

VIDEO LOSS - OFFTITLE -

PREVIOUS MENU

AMERICAN D YNA MIC S

ABCDEFGHIJKLMNOPQRSTUVWXYZabcdefghijklmnopqrstuvwxyz0123456789<>:-,/;

Use this menu to program a 2-line, 16-character title for the selected camera. In addition, you can set the video loss detection mode for the camera.

To change the camera title or video loss setting: 1. Move the cursor to the CAMERA number line.

2. Use the numeric keypad to enter the camera number (real or pseudo), and press the Enter (Preset) key. The cursor will move to the Title field.

3. Change the camera title:

a. Move the cursor to the TITLE lines. Two cursors display: the Title Cursor and the Selection Cursor.

b. Press the Next key to move the Title Cursor until the correct character in the title is highlighted.

Note: You must start from the first character in the title and move through the text until the desired character position is selected. You cannot backspace through the title.

c. Position the Selection Cursor by using the arrow keys or joystick to highlight the letter, number, or symbol to include in the title. Press the ENTER (Preset) key to add the selected character to the title.

d. Repeat steps 3b-3c to complete the title.

4. Change the camera video loss mode:

a. Place the cursor at the VIDEO LOSS line.

b. Press the ENTER (Preset) key to cycle through the loss detection modes. The following modes are available:

• OFF: Loss detection disabled.

• SYNC ONLY: Sync loss detection enabled.

• VIDEO LOW: Sync and low picture content video loss detection enabled.

• VIDEO MEDIUM: Sync and medium picture content video loss detection enabled.

• VIDEO HIGH: Sync and high picture content video loss detection enabled.

5. When finished making changes, press Exit (Patrn) to return to the previous menu.

Page 28: Using MegaPower 168 Matrix Switcher with AD2088 Keyboard …americandynamics.net/WebApps/getDocument.aspx?filename=8200-0170... · MEGAPOWER 168 / AD2088 OPERATION AND PROGRAMMING

MEGAPOWER 168 / AD2088 OPERATION AND PROGRAMMING REFERENCE GUIDE (8200-0170-01, REV. A)

28 of 30

Changing Preset Titles

When Preset Titles is selected from the Cameras menu, the following menu displays.

CAMERA - 0001

PRESET - 01

TITLE -

PREVIOUS MENU

AMERICAN D YNA MIC S

ABCDEFGHIJKLMNOPQRSTUVWXYZabcdefghijklmnopqrstuvwxyz0123456789<>:-,/;

Use this menu to program 2-line, 16-character titles for use with camera preset scenes. The Preset Titles are displayed in place of the Camera Title in the on-screen display when the associated preset number is called to that camera.

Note: A maximum of 4096 Preset Titles can be programmed for the system.

To program preset titles: 1. Move the cursor to the CAMERA number line. 2. Use the numeric keypad to enter the camera

number (real or pseudo), and press the Enter (Preset) key. The cursor will move to the Preset field.

3. Use the numeric keypad to enter the preset number (1-72) and press the Enter (Preset) key. The cursor moves to the Preset Title field.

4. Change the Preset Title: a. Move the cursor to the TITLE lines. Two

cursors display: the Title Cursor and the Selection Cursor.

b. Press the Next key to move the Title Cursor until the correct character in the title is highlighted. Note: You must start from the first character in the title and move through the text until the desired character position is selected. You cannot backspace through the title.

c. Position the Selection Cursor by using the arrow keys or joystick to highlight the letter, number, or symbol to include in the title. Press the ENTER (Preset) key to add the selected character to the title.

d. Repeat steps 4b-4c to complete the title. 5. When finished making changes, press Exit

(Patrn) to return to the previous menu.

Configuring User or Keyboard Settings The Users/Keyboards menu is used to set priority levels for keyboards or users, to set user numbers and passcodes, and to configure each of the eight priority levels.

Note: If USER IDs are enabled in the System Options menu, the first entry in the USERS / KEYBOARDS menu reads USER.

USERS / KEYBOARDS

1. USER2. PRIORITY

RETURN MAIN

If USER IDs are disabled in the System Options menu, the first entry in the menu reads KEYBOARD.

USERS / KEYBOARDS

1. KEYBOARD2. PRIORITY

RETURN MAIN

To select an entry from the USERS/KEYBOARDS menu: 1. Move the cursor to the desired line, or enter the

number (1-2) for the desired selection.

2. Press the Enter (Preset) key to access the associated menu.

Page 29: Using MegaPower 168 Matrix Switcher with AD2088 Keyboard …americandynamics.net/WebApps/getDocument.aspx?filename=8200-0170... · MEGAPOWER 168 / AD2088 OPERATION AND PROGRAMMING

MEGAPOWER 168 / AD2088 OPERATION AND PROGRAMMING REFERENCE GUIDE (8200-0170-01, REV. A)

29 of 30

Changing User Settings If User IDs are enabled and User is selected from the Users/Keyboards menu, the following menu is displayed:

USER

USER # - 01PRIORITY LEVEL 8PASSCODE

XXXXXX

PREVIOUS MENU

Use this menu to assign priority levels and passcodes to the selected user number.

To change user settings:

1. Move the cursor to the USER line. 2. Use the numeric keypad to enter the user

number (1-64). 3. Press the Enter (Preset) key to accept the user

number and move to the PRIORITY LEVEL menu item.

4. Use the numeric keypad to enter the Priority Level (1-8), and press the Enter (Preset) key to save. Note: Priority levels are individually configurable. “8” represents the highest priority level; “1” represents the lowest priority. Users with higher priority levels can capture control of cameras from users with lower priority levels.

5. Set or change the Passcode for the selected user: a. Enter a passcode (6 digits maximum). Press

the Enter (Preset) key. The system displays “VERIFY PASSCODE” on the monitor.

b. Re-enter the same passcode. Press the Enter (Preset) key. If the code verifies, the passcode is saved for this user number. The next time this user logs on to the system, this passcode must be used. If the code does not match the code entered in step 5a, the following error message is displayed: **ERROR - REENTER PASSCODE**. Repeat steps 5a and 5b.

6. When finished making changes, press Exit (Patrn) to return to the previous menu.

Changing Keyboard/Priority Settings If User IDs are disabled and Keyboard is selected from the Users/Keyboards menu, the following menu is displayed:

KEYBOARD

KEYBOARD - O1PRIORITY LEVEL 8

PREVIOUS MENU

Use this menu to assign priority levels to the selected keyboard. All keyboards default to level “8” priority.

Keyboard Numbering

Eight RS-232 ports are provided on the rear of the system CPU module. It is possible to expand the eight ports using AD1981 Port Expanders to a maximum of 32 keyboard ports, For appropriate keyboard numbering, verify if a port expander is used with each port.

The following table shows the appropriate keyboard designations with and without port expanders.

Table 9: Keyboard Numbers

Port # With Expander

Without Expander

Port 1 1-4 1

Port 2 5-8 5

Port 3 9-12 9

Port 4 13-16 13

Port 5 17-20 17

Port 6 21-24 21

Port 7 25-28 25

Port 8 29-32 29

Page 30: Using MegaPower 168 Matrix Switcher with AD2088 Keyboard …americandynamics.net/WebApps/getDocument.aspx?filename=8200-0170... · MEGAPOWER 168 / AD2088 OPERATION AND PROGRAMMING

MEGAPOWER 168 / AD2088 OPERATION AND PROGRAMMING REFERENCE GUIDE (8200-0170-01, REV. A)

30 of 30

Changing Keyboard Priority Levels

1. Move the cursor to the KEYBOARD menu item.

2. Use the numeric keypad to enter the desired keyboard number (1-32), and press the Enter (Preset) key. The cursor moves to the PRIORITY LEVEL menu item.

3. Use the numeric keypad to enter the Priority Level (1-8), and press the Enter (Preset) key to save.

Note: Priority levels are individually configurable. In general, “8” should represent the highest priority level; “1” should represent the lowest priority level. Keyboards with higher priority levels can capture control of cameras from keyboards with lower priority levels.

4. When finished making changes, press Exit (Patrn) to return to the previous menu.

Configuring Priority Settings If Priority is selected from the Users/Keyboards menu, the following menu is displayed:

PRIORITY

LEVEL 1ADD USER YSYSTEM RESET YLOCK CAM ABILITY Y

OVERRIDE NMENU ACCESS YCHANGE PARAMETERS Y

PREVIOUS MENU

Use this menu to configure settings associated with adding users, resetting the system, locking cameras, override, menu access, and changing system parameters for each of the 8 priority levels.

To configure a Priority Level: 1. Move the cursor to the LEVEL menu item.

2. Use the numeric keypad to enter the priority level number (1-8), and press the Enter (Preset) key.

3. Move the cursor to the menu item you want to change. Press the Enter (Preset) key to change the setting. The available setting for each menu item is Y (enabled) or N (disabled). The following settings can be configured:

Add User: If enabled (Y), the selected priority level can add new users. If disabled (N), the selected priority level cannot add new users.

Note: The USER IDs setting must be enabled for the Add User setting to apply.

System Reset: If enabled (Y), the selected priority level can reset the system by keyboard commands. If disabled (N), the selected priority level cannot reset the system by keyboard commands.

Lock Cam Ability: If enabled (Y), the selected priority level can lock the control of a camera by keyboard commands. If disabled (N), the selected priority level cannot lock the control of a camera by keyboard commands.

Override: If enabled (Y), the system uses partitioning tables to provide or deny access to camera view and/or control, and the selected priority level cannot override the partitioning. If disabled (N), the selected priority level can override the keyboard/camera view and control partitioning restrictions.

Menu Access: If enabled (Y), the selected priority level has access to the programming menus through the keyboard. If disabled (N), the selected priority level does not have access to the programming menus through the keyboard.

Note: Menu Access must be enabled to access the Change Parameters setting.

Change Parameters: If enabled (Y), the selected priority level can change system data through the menus. If disabled (N), the selected priority level cannot change system data through the menus.

Note: If Menu Access is disabled for the selected priority level, Change Parameters is automatically disabled and cannot be changed.

4. When finished making changes, press Exit (Patrn) to return to the previous menu.