Upload
others
View
3
Download
0
Embed Size (px)
Citation preview
1
User Manual,,of the S2 Weather Station”
Description of the device
Front view
Back view
2
Weather forecast
Turn on the Alarm Clock
Time
Record indicator
Indoor temperature
Outdoor temperature
Turning off the Alarm Clock/Settingthe brightness of the display screen
Cover of the batteries compartment
Up/Reception of the DCF radio signal
To set (set)
ALARM
Down/ activation of receptionof the DCF signal
To reset (reset)
DC connector
Holder
To reset (reset)
LED (abbreviation from
“light-emitting diode”)
Put one CR2032 batteryto the batteries compartment
Channel 1Channel 2Channel 3
Put two AAA batteries.
Outdoor temperature sensor
Warning!The weather station is equipped with an atomic clock obtained with the use of wireless tech-nology. Possibility of signal reception in wireless devices may depend on external factors such as:
Remember to place the device in a place with an optimal signal. Preferably, it should be placed near a window at a suitable distance from metal surfaces and electrical devices.
Significant transmission distance Location inside concrete buildingsClose location of: - Electrical devices - Mountains and valleys - High buildings - Level crossings, high voltage cables etc. - Computers and televisions - Metal constructions.
Operating temperature
Temperature measurement range
Indoor
Outdoor
Temperature differentiation
Alarm Clock duration
Snooze duration
Radio frequency
Transmitter range
0-+45 C
0-50 C
-25 C - +70 C
1 C
2 minutes
5 to 60 min
433 MHz
30m in free space and without interferences
Specification
3
Technical data
Quick Set
1.
2.
3.
4.
Plug the power adapter providing the power supply to the weather station to a permanent electrical energy source (without a wall switch) with alternating voltage 120v – 230V.
Place the mirror behind the weather station next to the wireless external transmitter. There is a cover in the rear part of the external transmitter. Slide it and open, then put 2 AAA alkali-ne batteries inside. Make sure the channel switch is set to position 1. Put the bat-tery com-partment cover back in place.
The weather station will start receiving a signal from the external transmitter within few seconds. In the end, put the external transmitter in a dry and shaded place.
In the event of a power cut, repeat the device setting procedure.
4
s2 weather station configuration
Installation of back-up batteries in the device
If there is a power failure, the illumination will turn off. in such case, the back-up battery will main-tain the time and all settings of the device.
Open the battery compartment by sliding the cover on the rear side of the device. Then put a CR2032 lithium battery (not included) so that the part of the battery marked with + was directed upwards. Then close the battery compartment completely by pressing the cover.
Warning!The external transmitter handles transmission in an open space for a distance up to 30 meters. However, the actual transmission range may vary depending on the signal's route. It means that each obstacle (roof, walls, floors, ceilings, high trees etc.) reduces the transmis-sion range by half.
5
s2 weather station configuration
Battery compartment cover
Put one CR2032 battery to the battery case
When the Weather Station receives the necessary data - information about the temperature in the place where the external sensor is installed, it will start searching for a time signal (transmitted by a DCF transmitter from Germany).
If you press button, when the station is switched on, an information about the mode and intensity of DCF transmitter will appear on the screen. This intensity is distinguished trough indica-tion on the screen: from one bar (which means the weakest signal) up to three (he strongest sig-nal).
When the clock receives a radio-controlled time signal, the buttons are not active, and the bright-ness of the display screen is reduced. Once the signal is received, the brightness of the display screen will be back to normal.
Upon reception of DCF time code, the weather station will automatically update an accurate time. The clock will try to receive the DCF signal automatically every night at: 1:00 AM, 2:00 AM, 3:00 AM If it fails till 3.00 AM, the device will try to receive the signal once again at 4:00 AM and 5:00 AM. In case of failure, the device will stop attempts of reception till 1:00 AM on the next day.
In order to launch the DCF signal reception manually, press the button. In order to stop reception of the DCF signal, press the button once again.
6
s2 weather station configuration
Reception of the DCF time signal
/ WAVE
/ WAVE
/ WAVE
WARNING
The clock of the Weather Station works according to the 24-hour time display mode.
Time setting: press and hold SET - wait until digits corresponding to hours start flashing on the screen of the main unit. Then set proper hour using buttons and confirm with SET button – digits corresponding to minutes will start flashing on the screen.
Stopping the alarm: set minutes using the buttons and then confirm your choice with SET button –
05 will start flashing on the screen. In such way, you will stop the alarm with SNOOZE button for 5-60 minutes.
Time zone: press SET button. Then, using the buttons, specify the time zone, enter-ing the difference from the Coordinated Universal Time - UTC (GMT);
00 for a local time equivalent to the universal time + 1 hour (e.g. Germany) 01 for a local time equivalent to the universal time + 2 hours (e.g. France) -01 for the local time in United Kingdom. Confirm with SET button.
Press and hold AL. button that corresponds to alarm - digits and hours of alarm clock will start flashing then, the AL symbol will flash too.
Programme the alarm time with the button, confirm with the AL button. Digits corresponding to minutes in the time of alarm will start flashing on the screen.
7
s2 weather station configuration
Manual settings of the S2 weather station
Alarm clock settings
Use buttons to programme minutes of the alarm, confirm them with the AL but-ton. In this way, the device will be switched to a normal mode and the time and AL icon will be displayed on the screen.
In order to switch off the alarm programme, press the AL button. The AL. icon will dis-appear.
8
s2 weather station configuration
Weather forecast
The station is equipped with the weather forecast function. Thanks to this function, the display screen of the main unit shows main weather types actual for the neighbourhood of the place in which the device is located.
Weather forecast icon Type of the predicted weather
Sunny
Moderate Clouds
Clouds
Rain
9
s2 weather station configuration
In order to set the desired brightness of the screen, press the DIMMER button twice.
Display screen brightness settings
display brightness settings
If the weather station displays incorrect data or digits, that may be caused by electrostatic dis-charges or interferences from other devices. In in such case, press the RESET button using a sharp tool. The device will reset itself to the default settings, then you will have to set the time, calendar and alarm clock time once again.
Troubleshooting
Reset (reset)
10
s2 weather station configuration
Remember not to expose the device to high temperatures, water or direct sunlight. Avoid any contact of the device with corrosive materials. Do not open the internal cover and do not interfere into the parts of the device. Do not connect the device to any power adapters with improper specification or wrong voltage.
MAINTENANCE AND CLEANING
Karpicko, ul. Podgórna 16, 64-200 Wolsztyn
Mail EU: [email protected]; Mail PL: [email protected]+48 68 422 73 65
We work from Monday to Friday from: 9: 00 AM to 3. 00 PM
FORAM Sp. z o.o. sp. k.
NIP 923-172-93-78, REGON 381749814