Page 1: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

AX PRO

User Manual

Page 2: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

AX PRO User Manual

i

Legal Information

© 2021 Hangzhou Hikvision Digital Technology Co., Ltd. All rights reserved.

About this Manual

The Manual includes instructions for using and managing the Product. Pictures, charts, images and all other information hereinafter are for description and explanation only. The information contained in the Manual is subject to change, without notice, due to firmware updates or other reasons. Please find the latest version of this Manual at the Hikvision website (https://www.hikvision.com/). Please use this Manual with the guidance and assistance of professionals trained in supporting the Product.

Trademarks

and other Hikvision's trademarks and logos are the properties of

Hikvision in various jurisdictions. Other trademarks and logos mentioned are the properties of their respective owners.

Disclaimer

TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THIS MANUAL AND THE PRODUCT DESCRIBED, WITH ITS HARDWARE, SOFTWARE AND FIRMWARE, ARE PROVIDED “AS IS” AND “WITH ALL FAULTS AND ERRORS”. HIKVISION MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION, MERCHANTABILITY, SATISFACTORY QUALITY, OR FITNESS FOR A PARTICULAR PURPOSE. THE USE OF THE PRODUCT BY YOU IS AT YOUR OWN RISK. IN NO EVENT WILL HIKVISION BE LIABLE TO YOU FOR ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT DAMAGES, INCLUDING, AMONG OTHERS, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, OR LOSS OF DATA, CORRUPTION OF SYSTEMS, OR LOSS OF DOCUMENTATION, WHETHER BASED ON BREACH OF CONTRACT, TORT (INCLUDING NEGLIGENCE), PRODUCT LIABILITY, OR OTHERWISE, IN CONNECTION WITH THE USE OF THE PRODUCT, EVEN IF HIKVISION HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSS. YOU ACKNOWLEDGE THAT THE NATURE OF INTERNET PROVIDES FOR INHERENT SECURITY RISKS, AND HIKVISION SHALL NOT TAKE ANY RESPONSIBILITIES FOR ABNORMAL OPERATION, PRIVACY LEAKAGE OR OTHER DAMAGES RESULTING FROM CYBER-ATTACK, HACKER ATTACK, VIRUS INSPECTION, OR OTHER INTERNET SECURITY RISKS; HOWEVER, HIKVISION WILL PROVIDE TIMELY TECHNICAL SUPPORT IF REQUIRED. YOU AGREE TO USE THIS PRODUCT IN COMPLIANCE WITH ALL APPLICABLE LAWS, AND YOU ARE SOLELY RESPONSIBLE FOR ENSURING THAT YOUR USE CONFORMS TO THE APPLICABLE LAW. ESPECIALLY, YOU ARE RESPONSIBLE, FOR USING THIS PRODUCT IN A MANNER THAT DOES NOT INFRINGE ON THE RIGHTS OF THIRD PARTIES, INCLUDING WITHOUT LIMITATION, RIGHTS OF PUBLICITY, INTELLECTUAL PROPERTY RIGHTS, OR DATA PROTECTION AND OTHER PRIVACY RIGHTS. YOU SHALL NOT USE THIS PRODUCT FOR ANY PROHIBITED END-USES, INCLUDING THE DEVELOPMENT OR PRODUCTION OF WEAPONS OF MASS DESTRUCTION, THE DEVELOPMENT OR

Page 3: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

AX PRO User Manual

ii

PRODUCTION OF CHEMICAL OR BIOLOGICAL WEAPONS, ANY ACTIVITIES IN THE CONTEXT RELATED TO ANY NUCLEAR EXPLOSIVE OR UNSAFE NUCLEAR FUEL-CYCLE, OR IN SUPPORT OF HUMAN RIGHTS ABUSES. IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE LAW, THE LATER PREVAILS. Data Protection During the use of device, personal data will be collected, stored and processed. To protect data, the development of Hikvision devices incorporates privacy by design principles. For example, for device with facial recognition features, biometrics data is stored in your device with encryption method; for fingerprint device, only fingerprint template will be saved, which is impossible to reconstruct a fingerprint image. As data controller, you are advised to collect, store, process and transfer data in accordance with the applicable data protection laws and regulations, including without limitation, conducting security controls to safeguard personal data, such as, implementing reasonable administrative and physical security controls, conduct periodic reviews and assessments of the effectiveness of your security controls.

Page 4: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

AX PRO User Manual

iii

Symbol Conventions

The symbols that may be found in this document are defined as follows.

Symbol Description

Danger Indicates a hazardous situation which, if not avoided, will or could result in death or serious injury.

Caution Indicates a potentially hazardous situation which, if not avoided, could result in equipment damage, data loss, performance degradation, or unexpected results.

Note Provides additional information to emphasize or supplement important points of the main text.

Page 5: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

AX PRO User Manual

iv

Regulatory Information

EN 50131-1:2006+A1:2009+A2:2017

EN 50131-3:2009

EN 50131-6:2017

EN 50131-5-3:2017

EN 50131-10: 2014

EN 50136-2: 2013

Security Grade (SG): 2

Environmental Class (EC) : II

DP2

Certified by Telefication

Note EN50131 compliance labeling should be removed if non-compliant configurations are used.

EU Conformity Statement

This product and - if applicable - the supplied accessories too are marked with "CE" and comply therefore with the applicable harmonized European standards listed under the EMC Directive 2014/30/EU, RE Directive 2014/53/EU,the RoHS Directive 2011/65/EU

2012/19/EU (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points. For more information see: www.recyclethis.info

2006/66/EC (battery directive): This product contains a battery that cannot be disposed of as unsorted municipal waste in the European Union. See the product documentation for specific battery information. The battery is marked with this symbol, which may include lettering to indicate cadmium (Cd), lead (Pb), or mercury (Hg). For proper recycling, return the battery to your supplier or to a designated collection point. For more information see:www.recyclethis.info

Page 6: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

AX PRO User Manual

v

Warning

This is a class A product. In a domestic environment this product may cause radio inter-ference in which case the user may be required to take adequate measures.

FCC Information

Please take attention that changes or modification not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

FCC compliance: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

—Reorient or relocate the receiving antenna.

—Increase the separation between the equipment and

receiver.

—Connect the equipment into an outlet on a circuit different

from that to which the receiver is connected.

—Consult the dealer or an experienced radio/TV technician for

help.

This equipment should be installed and operated with a minimum distance 20cm between the radiator and your body.

FCC Conditions

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

1. This device may not cause harmful interference.

2. This device must accept any interference received, including interference that may cause undesired operation.

Page 7: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

AX PRO User Manual

vi

Contents

Chapter 1 Introduction ................................................................................................................... 9

1.1 System Description ........................................................................................................... 9

1.2 Specification ................................................................................................................... 10

1.3 Appearance ..................................................................................................................... 14

Chapter 2 Start Up ........................................................................................................................ 17

2.1 Initial the Device ............................................................................................................. 17

2.2 Install the Device ............................................................................................................ 18

Chapter 3 User Management ....................................................................................................... 20

3.1 User Management .......................................................................................................... 20

3.1.1 Invite the Administrator ....................................................................................... 20

3.1.2 Cancel Installer Access ......................................................................................... 21

3.1.3 Add an Operator .................................................................................................. 22

3.1.4 Delete an Operator .............................................................................................. 23

3.2 Access Entries ................................................................................................................. 23

Chapter 4 Configuration ............................................................................................................... 25

4.1 Set-up with Hik-Proconnect ............................................................................................ 25

4.1.1 Use the Hik-Proconnect APP ................................................................................ 25

4.1.2 User the Hik-ProConnect Portal ........................................................................... 36

4.2 Set-up with Hik-Connect ................................................................................................. 40

4.3 Set-up with the Web Client ............................................................................................. 48

4.3.1 Communication Settings ...................................................................................... 49

4.3.2 Device Management ............................................................................................ 62

4.3.3 Area Settings ........................................................................................................ 70

4.3.4 Video Management .............................................................................................. 72

4.3.5 Permission Management ..................................................................................... 74

4.3.6 Maintenance ........................................................................................................ 75

4.3.7 System Settings .................................................................................................... 77

4.3.8 Check Status ......................................................................................................... 89

4.4 Report to ARC (Alarm Receiver Center) .......................................................................... 90

Page 8: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

AX PRO User Manual

vii

Setup ATS in Transceiver of Receiving Center ............................................................... 90

Setup ATS in Transceiver of the Panel ........................................................................... 91

Signaling Test ................................................................................................................ 92

Chapter 5 General Operations ...................................................................................................... 94

5.1 Arming ............................................................................................................................ 94

5.2 Disarming ........................................................................................................................ 95

5.3 SMS Control .................................................................................................................... 95

A. Trouble Shooting ...................................................................................................................... 96

A.1 Communication Fault ..................................................................................................... 96

A.1.1 IP Conflict ............................................................................................................. 96

A.1.2 Web Page is Not Accessible ................................................................................. 96

A.1.3 Hik-Connect is Offline .......................................................................................... 96

A.1.4 Network Camera Drops off Frequently ................................................................ 96

A.1.5 Failed to Add Device on APP ................................................................................ 96

A.1.6 Alarm Information is Not Reported to APP/4200/Alarm Center ......................... 97

A.2 Mutual Exclusion of Functions ........................................................................................ 97

A.2.1 Unable to Enter Registration Mode ..................................................................... 97

A.3 Zone Fault ....................................................................................................................... 97

A.3.1 Zone is Offline ...................................................................................................... 97

A.3.2 Zone Tamper-proof .............................................................................................. 97

A.3.3 Zone Triggered/Fault ........................................................................................... 97

A.4 Problems While Arming .................................................................................................. 98

A.4.1 Failure in Arming (When the Arming Process is Not Started) .............................. 98

A.5 Operational Failure ......................................................................................................... 98

A.5.1 Failed to Enter the Test Mode.............................................................................. 98

A.5.2 The Alarm Clearing Operation on the Panel Does Not Produce the Alarm Clearing Report ................................................................................................................... 98

A.6 Mail Delivery Failure....................................................................................................... 98

A.6.1 Failed to Send Test Mail ....................................................................................... 98

A.6.2 Failed to Send Mail during Use ............................................................................ 99

A.6.3 Failed to Send Mails to Gmail .............................................................................. 99

A.6.4 Failed to Send Mails to QQ or Foxmail ................................................................. 99

Page 9: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

AX PRO User Manual

viii

A.6.5 Failed to Send Mails to Yahoo ............................................................................. 99

A.6.6 Mail Configuration ............................................................................................. 100

B. Input Types ............................................................................................................................. 101

C. Output Types .......................................................................................................................... 104

D. Event Types ............................................................................................................................ 105

E. Access Levels .......................................................................................................................... 106

F. Signalling ................................................................................................................................ 108

Detection of ATP/ATS Faults ............................................................................................... 108

ATS Category ...................................................................................................................... 108

G. SIA and CID Code .................................................................................................................... 109

H. Communication Matrix and Operation Command ................................................................. 115

Page 10: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

9

Chapter 1 Introduction

1.1 System Description

AX Pro is a wireless alarm system designed to protect premises required for proper protection from intrusion alarm. It supports LAN /Wi-Fi as the primary transmission network. The system is applicable to the scenarios of market, store, house, factory, warehouse, office, etc. ● Innovative Tri-X 2-way wireless technology.

● Two-way communication with AES-128 encryption.

● Frequency-hopping spread spectrum (FHSS) is used to avoid interference, to prevent

eavesdropping, and to enable code-division multiple access (CDMA) communications.

● Voice guide for alarm alert, system status indication, operation prompt, etc.

● Configuration via web client, mobile client, and Convergence Cloud.

● Pushes alarm notification via messages or phone calls.

● Views life videos from Hik-Connect and alarm video clips via emails, Hik-ProConnect, and Hik-

Connect.

● Uploads alarm reports to ARC.

● SIA-DC09 protocol, and supports both Contact ID and SIA data format.

● 4520 mAh lithium backup battery with 12 H standby duration.

Page 11: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

10

1.2 Specification

AX PRO E

Capacity

Areas 8

Zones Up to 48 (Up to 48 PIRCAMs)

Outputs

Tag Readers Up to 8

Keypads

Sounders 4 (2 Internal+2 External)

Repeaters 2

Keyfobs 16

Tags 16

User

Installer 1

Administrator 1

Normal Users 14

Wireless technical characteristics

RF Frequency 433 Mhz

Wireless type 2-way wireless

Wireless Security Frequency Hoping 128 AES Encryption

Functional Features

Voice Prompts √

User APP for operating √

Installer APP for programming √

Web server for maintenance (offline configuration)

Event Log Records 5000 including 1000 mandatorya

PIR Camera Support √

Communication interfaces

Ethernet 10/100 Mbps self-adaptive

Wi-Fi 802.11b/g/n (2.4GHz)

ARC Signaling Protocols

SIA DC09(SIA level 2, Contact ID), ISUP, ISAPI (SDK) Hik-IP Receiver & Hik-IP Receiver Pro (Sur-Gard &

Ademco 685) Supports video verification and remote control

Cloud Services Hik-ProConnect Service √

Hik-Connect Service √

Automation

Wall-Switch √

Relay Module √

Smart Plug √

Power Supply

Mains Input ~ 100-240V 50/60Hz 0.3A(Max)

Battery Capacityd 4520 mAh

Battery Standbye Up to 12 hrs

Battery Type Built-in rechargeable Lithium-ion polymer battery

Model: 765965

Page 12: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

11

Current Consumption With an alarm: 405mA Without an alarm: 340mA

Current when on Battery 340 mA

Recharge Period 4 hrs to 80%

Low Voltage Message 3.55 V

Service No user service parts inside

Environmental Requirements

Operating Temperature -10°C to 50°C

﹣10℃ to+40℃ (Certified temperature)

Relative Humidity 10% ~ 90% noncondensing

Size & Weight Dimension (W×H×D) 170.0 mm (6.7") × 170.0 mm (6.7") ×38.6 mm (1.5")

Weight 557.5 g (19.7 oz)

Approvals

CE/CB √

Rohs/Reach/WEEE √

FCC √

RCM √

b

AX Pro wireless control panel is compatible with SIA IP Reporting (UDP/TCP-2013) as per ANSI/SIA DC-09-2013: Internet Protocol Event Reporting. The control panel supports tokens (protocols) of ADM-CID and SIA-DCS defined in SIA DC-07-2001.04, which will be modified to insert a “*” before token name as *ADM-CID and *SIA-DCS when the data and timestamp of transmission message are AES encrypted. AES-128, AES-192 and AES-256 are all supported.

d

Nominal value. Actual capacity may vary slightly. The actual battery capacity for each individual device may be slightly above or below the nominal battery capacity. Removing the battery may cause damage to the device. To replace or repair the battery, please contact your installer.

e In the condition of Wi-Fi connected, GPRS/3G/4G LTE connected, ARC connected (polling interval: 1800 s), 8 inputs and 1 keypad accessed, and cloud service accessed.

Note

ISUP5.0: a privacy internet protocol that is used for accessing the third-party platform, which supports alarm report uploading, AX PRO management, and short video uploading. The prioritization of the message and indications are the same. The AXPRO uploads messages and gives indications synchronously.

Page 13: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

12

Note

Standard DC-09 Protocol: ADM-CID: The data presenting method of DC-09 is CID, which is not encrypted and only for uploading alarm report. *ADC-CID: The data presenting method of DC-09 is CID, which is encrypted and only for uploading alarm report. SIA-DCS: The data presenting method of DC-09 is DCS (also called SIA protocol), which is not encrypted and only for uploading alarm report. *SIA-DCS: The data presenting method of DC-09 is DCS (also called SIA protocol), which is encrypted and only for uploading alarm report.

Page 14: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

13

RSSI Instruction for Peripherals With regards to EN 50131-5-3 4.2.2 Requirement for immunity to attenuation.

Signal Strength RSSI Value Indication Remark

Strong >120 Green OK to install

Medium 81 to 120 Yellow OK to install

Weak 60 to 80 Red Not recommend to install, but can work

Invalid 0 to 59 Red (flash) Not OK to install, cannot work normally

Note

Install peripherals only if the signal strength is above 80. For getting a much better system, install at 120 and above.

AX PRO Notification Options The AX PRO is suitable for the below notification requirements along with the required sounders

Notification equipment

I&HAS Grade 2

Options

C E F

Self powered audible WD

2 1 Optional

ATS DP1 Optional DP2

Page 15: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

14

1.3 Appearance

Front Panel

Table 1-2 Front Panel Description

No. Name Description

1 Alert Indicator

Solid Orange: In the disarming status, the LED indicates alarm (such as panic alarm, zone alarm, tampering alarm, etc.) and fault (such as operation fault, connection fault, etc.)

Note

● The indicator or voice notifications will not response to any operation made by level 1 users. Notifications will only response when level 1 user presents or uses a valid tag or keyfob.

● The device will prompt detailed alarm or fault information while the authorized users disarm the system.

2 Link Indicator Solid Green: The panel is bound to Hik-connect account

Off: The panel is not bound to Hik-connect account

3 Arm/Disarm Indicator Solid Blue for 5 s: Armed

Green Flashes Twice: Disarmed

Page 16: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

15

No. Name Description

Note

If the function of Arming Indicator Keeps Light is enable, the LED keeps solid blue when armed, and off when disarmed. The function does not compliant with EN standard.

4 Alarm Indicator

Flashing Red: Alarm Occurred

Solid Red: Device Tampered

Off: No Alarm

5 Power Indicator Solid Green: Power on

Off: Power off

6 Tag Present Area Note

The function varies according to the model of device.

Component and Interface

Remove the rear cover, and some of the components and interfaces are on the rear panel.

Table 1-3 Rear Panel Description

Number Description

7 Tamper Switch

8 Reset Button

Page 17: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

16

Number Description

Note

Restart the device, the power LED flashes 3 times, and hold the reset button for 5 s. The voice prompt indicates the operation result. Press the button to switch the STA and Hotspot mode.

9 Power Interface

10 Power Switch

11 Network Interface

12

SIM Card Slot 1

Note

The function of GPRS or 3G/4G (implemented with built-in SIM card slot) varies depends on the model of the device.

13

SIM card Slot 2

Note

The function of GPRS or 3G/4G (implemented with built-in SIM card slot) varies depends on the model of the device.

Page 18: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

17

Chapter 2 Start Up

2.1 Initial the Device

While initial the device with Hik-ProConnector, the AX Pro should always be add to an installer account first. The installer account will invite and transfer ownership to the administrator account later after finishing all initial setup and test. Follow the steps below to initializing the wireless alarm system. 1. Connect to the network. Connect the device to the Ethernet, and power the device on.

Note

While the device is powered on, the power LED and link LED turn green.

2. Create a site Open the Hik-ProConnect and login with the installer account.

Page 19: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

18

A site is the place where the alarm system deployed. Create a site where the device can be added to with it’s site name and address. The owner of the site would be an end user, usually regarded as administrator.

3. Add Device Open the site. Tap Add Device and scan the QR code on the label of the panel.

The control panel will be added to the site created and managed by the installer account, which also means that the installer account was created in the panel.

The installer now can perform configuration and tests of the panel before deploying. Both Hik-ProConnect Service and local web client can be logged in with the Hik-ProConnect installer account.

Note

While initial the device with Hik-connect, you do not need to build a site first. Download and login the App, and add the device by scanning QR code or enter the device serial No..

2.2 Install the Device

Steps

1. Loosen the screw on the rear cover. Slide down the rear cover and remove it from the AX PRO.

2. Secure the rear cover to the installation position with the supplied screws. Attach the AX PRO

on the rear cover, and tighten the rear cover screw to complete the installation.

Page 20: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

19

Note

● Red Star: TAMPER Screw. It is compulsory to secure the TAMPER screw. ● No adjustments are required. ● For use within the supervised premises only.

Note

Check the RF signal strength before connection and peripheral device installation. You can view the RF signal strength indication on the peripheral device.

Page 21: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

20

Chapter 3 User Management

3.1 User Management

Note

● The users can be created in clients. ● The name and password of network user (web client and APP user)can be 1 to 32 characters

and 8 to 16 characters.

3.1.1 Invite the Administrator The administrator was known as site owner in Hik-ProConnect Service.

After the initial configuration finished, the installer shall invite the site owner and apply permission of site management and device configuration from the administrator account. The administrator account would be an end user account in the Hik-Connect Service.

Press “Invite Now” Button and enter the email account or phone number account to transfer the site ownership to the administrator. At the same time, the installer will apply permissions from the site owner, such as configuration and management.

Open the Hik-Connect app and login with the administrator account. The installer service request will be received at notification page. Open the notification detail to accept the installer service and setup permissions. The control panel and other devices in the site will be displayed at your device list.

Page 22: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

21

The administrator account will be added to the control panel, which could be used to login to Hik-Connect app and local web client.

3.1.2 Cancel Installer Access The administrator can cancel the access authorization of the installer.

1. Enter the page More and tap Hik-ProConnect. All sites that managed by the Hik-ProConnect Service are listed on the page.

2. Tap the option button at the top-right corner of the site details page, and tap Cancel Authorization in the prompt menu.

3. Confirm the operation, and the authorization of the installer will be canceled. Once the authorization is canceled, the installer need to apply it again if any access requirement.

Page 23: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

22

3.1.3 Add an Operator The administrator can share the device to other operators.

1. Tap the (share button) in the device list.

2. Enter the Hik-Connect account of the operator.

Administrator can also select which device to be shared.

A sharing message will be sent to the operator’s account, and the operator can read the message in the Hik-Connect app.

3. Accept the invitation, and the device will be listed in the device list.

Page 24: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

23

The operator account will be added to the control panel, which could be used to login to Hik-Connect app and local web client.

3.1.4 Delete an Operator Administrator user can delete an operator.

1. Enter the page More and tap Manage Sharing Settings.

2. Delete the selected operator or remove it from the device.

3.2 Access Entries

The installer and operators of the AXPRO were assigned different access levels which define the system functions that an individual user can perform. Various user entries are provided for different user roles with particular access level.

Access entries for Installers (Access Level 3) Hik-ProConnect Service

Hik-ProConnect is a service for installers that is used to manage customers’ alarm systems located in various sites remotely. Control panels can be added to an installer account on the Hik-ProConnect Service and be managed in sites.

Local Web Client

Visit the device IP address that can be found out with SADP tool. The installer can login with Hik-ProConnect service account after the panel was added.

Legacy entries

Keypad PINs and tags can be also assigned with installer user at particular access level to

Page 25: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

24

perform essential operations.

Access Entries for the Administrator and Operators (Access Level 2) Hik-Connect Service

The Hik-Connect service can be used for end users to access and manage the devices.

Local Web Client (for the administrator)

As soon as the panel was added to the end user account on Hik-Connect Service, the Hik-Connect account can be used to login to the web client build in.

Operators cannot login the web client.

Legacy entries

Keypad PINs and tags can be also assigned with end user at particular access level to perform essential operations.

Page 26: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

25

Chapter 4 Configuration

4.1 Set-up with Hik-Proconnect

4.1.1 Use the Hik-Proconnect APP The installer can use the Hik-Proconnect to configure the AX PRO, such as activation, device enrollment etc.

Download and Login the Hik-ProConnect

Download the Hik-ProConnect mobile client and login the client before operating the AX PRO.

Steps

1. Download Hik-ProConnect mobile client. 2. Optional: Register a new account if it is the first time you use the Hik-ProConnect mobile client.

Note

● For details, see User Manual of Hik-ProConnect Mobile Client. ● You need an invitation code for registration. Please ask technical supports.

3. Run and login the client.

Add AX PRO to the Mobile Client

Add AX PRO to the mobile client before other operations.

Steps

1. Power on the AX PRO. 2. Create or search a site.

– Tap +, set site name, time zone, address, city, state/province/region and tap OK to create a site.

– Enter site name in the search area and tap Search Icon to search a site. 3. Tap Add Device.

– Tap Scan QR Code to enter the Scan QR code page. Scan the QR code on the AX PRO.

Note

Normally, the QR code is printed on the label stuck on the back cover of the AX PRO.

Tap Manual Adding to enter the Add Device page. Enter the device serial No. and verification code to add the device. 4. Activate the Device.

Page 27: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

26

Add Peripheral to the AX PRO

Add peripheral to the AX PRO.

Steps

1. Select a site. 2. Select a control device (AX PRO). 3. Tap the + icon.

– Tap Scan QR Code to enter the Scan QR code page. Scan the QR code on the peripheral. – Tap Manual Adding to enter the Add Device page. Enter the device serial No. and verification

code to add the device.

User Management

The installers (user of Hik-ProConnect) can manage users. If you are the administrator, you can add, edit, and delete users, and assign different permissions to the newly-added users.

Steps

Note

There are four types of users for the AX PRO, including administrator (or owner), operator, and installer (or setter). Different types of users have different permissions for accessing the functionality of the AX PRO.

1. Enter the site, tap the AX PRO and then log in to the device (if required) to enter the AX PRO page.

2. Tap Next to invite the user.

Note

The recipient need to accept the invitation.

3. Tap → User Management → User. 4. Tap a user to enter the User Management page. 5. Optional: Perform the following operations if required.

User Permission You can tap the target user on the user list and then tap Edit Icon to set the permissions authorized to the target user.

Note

Only the administrator can do such an operation.

Set Linked Areas If the target user is an operator, tap the target user on the user list and then tap Linked Areas to set the area linked to the target user.

Page 28: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

27

Note

Only the administrator can do such an operation.

Change Keypad Password

If the target user is an administrator, an installer, or an operator, you can tap the target user on the user list and then tap Change Keypad Password to set the keypad password to the target user.

Change Duress Password

If the target user is an administrator or an operator, you can tap the target user on the user list and then tap Change Duress Password to set the duress password to the target user.

Note

If under duress, you can enter the duress code on the keyboard to arm and disarm area(s) and upload a duress alarm.

Automation Control An administrator, an installer or an operator can control the relay module, wall switch and smart plug.

Note

● Configuration items and user permission will vary according to the user type. ● You can view linked cards/tags and keyfobs of the user but you do not have permission to

configure them.

Card/Tag Management

After adding cards/tags to the wireless AX PRO, you can swipe the card/tag to arm or disarm all the detectors added to specific area(s) of the AX PRO, and silence alarms.

Note

The tag ID/PIN is a 32 bit long integer, and the variant could be 42949672956.

Steps

1. Enter the site, tap the AX PRO and then log in to the device (if required) to enter the page. 2. Tap → User Management → Card/Tag to enter the Tag Management page. 3. Tap + to add a Tag. 4. When hearing the voice prompt "Swipe Tag", you should present the Tag on the AX PRO Tag

presenting area. ● When hearing a beep sound, the Tag is recognized.

Page 29: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

28

● The Tag will be displayed on the Tag page. 5. Optional: Tap a Tag to enter the Setting Page. 6. Tap Edit Icon to edit the Tag name.

Note

● If you log in as an installer, skip this step. Editing Tag name is only available to administrator. ● The name should contain 1 to 32 characters.

7. Slide Enable Tag.. 8. Select a linked user. 9. Select the Tag type

Note

Different linked users have different Tag permissions.

Operation Tag

You can swipe the Tag to arm or disarm.

Patrol Tag

When you swipe the Tag, the system will upload a record. 10. Optional: Tap Delete to delete the Tag.

System Settings

System Configuration

You can set the device time zone and set the DST time.

In the site, tap the AX PRO and then log in to the device (if required).

Tap → System → Configuration to enter the configuration page.

You can tap to select a time zone.

You can enable the DST and set the DST bias, DST start time, and DST end time.

System Options

Set the system options.

Option Management

In the site, tap the AX PRO and then log in to the device (if required). Tap → System → System

Page 30: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

29

Options → System Management to enter the page.

Forced Auto Arming

If the option is enabled and there are active faults in a zone, the zone will be bypassed automatically.

System Status Report

Switch for uploading system reports.

Voice Prompt

If the option is enabled, the AX PRO will enable the text voice prompt.

Audible Tamper Alarm

If the option is enabled, the system will alert with buzzer for the tamper alarm. If the option is disabled, peripherals will report lid opened, but not link to alarms.

System Volume

The available system volume range is from 0 to 10.

Panel Lockup Button

If the option is enabled, the installer can use the lockup button function to lock the AX PRO. After locking, users can not operate the device and receive messages.

Panel Alarm Duration

Set the time duration of the panel alarms.

Polling Loss Times

Set the maximum duration for polling loss. The system will report fault if the duration is over the limit.

Bypass on Re-Arm

The bypassed zone will back to arm if fault restored.

Fault Check

In the site, tap the AX PRO. Tap → System → System Options → Panel Fault Check to enter the page.

Detect Network Camera Disconnection

If the option is enabled, when the linked network camera is disconnected, an alarm will be triggered.

Battery Fault Check

If the option is enabled, when battery is disconnected or out of charge, the device will not upload events.

LAN Fault Check

If the option is enabled, when the wired network is disconnected or with other faults, the alarm will be triggered.

Page 31: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

30

Wi-Fi Fault Check

If the option is enabled, when the Wi-Fi is disconnected or with other faults, the alarm will be triggered.

Cellular Fault Check

If the option is enabled, when the cellular data network is disconnected or with other faults, the alarm will be triggered.

AC Power Loss Delay

The system checks the fault after the configured time duration after AC power down. To compliant the EN 50131-3, the check time duration should be 10 s.

System Instructions

In the site, tap the AX PRO and then log in to the device (if required). Tap → System → System Options → Arm Options to enter the page.

Arm with Faults

If the option is enabled, when there is a fault during the arming procedure, you can stop arming manually.

Early Alarm

If you enable the function, when the zone is armed and the zone is triggered, the alarm will be triggered after the delay time.

Early Alarm Time

When the early alarm function is enabled, you should set the early alarm time. The alarm will be triggered after the configured early alarm time.

Enrollment Mode

1. In the site, tap the AX PRO and then log in to the device (if required). 2. Tap → System → System Options → Enrollment Mode to enter the page. 3. Tap Enter the Enrollment Mode. 4. Follow the instructions on the page to add a device. 5. Tap Exit the Enrollment Mode.

Network Camera

Add Cameras to the AX PRO

Steps

1. In the site, tap the AX PRO and then log in to the device (if required). 2. Tap → Network Camera → Network Camera Channel to enter the page. 3. Tap Add Channel. 4. Enter IP address, port, the user name and password of the camera. 5. Tap Save Icon.

Page 32: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

31

6. Optional: tap Edit or Delete to edit or delete the selected camera.

Set Video Parameters

Steps

1. In the site, tap the AX PRO and then log in to the device (if required). 2. Tap → Network Camera → Event Video Settings to enter the page. 3. Select a camera and set the video parameters.

Stream Type

Main Stream: Being used in recording and HD preview, it has a high resolution, code rate and picture quality. Sub-Stream: It is used to transmit network and preview pictures as a video streaming with features of lower resolution, bit rate and picture quality.

Bitrate Type

Select the Bitrate type as constant or variable.

Resolution

Select the resolution of the video output.

Bitrate

The higher value corresponds to the higher video quality, but the better bandwidth is required.

Set Arming/Disarming Schedule

1. Set the arming/disarming schedule to arm/disarm a particular zone automatically. 2. In the site, tap the AX PRO and then log in to the device (if required). 3. Tap → Area to enter the page. 4. Tap an area in the list, enable the area and select linked areas. 5. Enable the auto arm/disarm function and set the auto arm time/auto disarm time. You can also

set the late to disarm time, entry delay time, exit delay time, sounder delay time, weekend exception and excepted holiday.

Auto Arm

Enable the area to automatically arm itself in a specific time point.

Auto Arm Time

Set the schedule for the area to automatically arm itself.

Auto Disarm

Enable the area to automatically disarm itself in a specific time point.

Auto Disarm Time

Set the schedule for the area to automatically disarm itself.

Late to Disarm

Page 33: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

32

Enable the device to push a notification to the phone or tablet to remind the user to disarm the area when the area is still armed after a specific time point.

Note

You should enable the Panel Management Notification function on the Web Client of Communication Parameters → Event Communication before enabling the Late to Disarm function.

Late to Disarm Time

Set the time point mentioned in Late to Disarm.

Weekend Exception

If enabled, Auto Arm, Auto Disarm, and Late to Disarm are disabled on the weekend.

Excepted Holiday

Enable the function and the zone will not be armed/disarmed in the holiday. You should set the holiday schedule after enabling.

Note

Up to 6 holiday groups can be set.

Communication

Cellular Data Network

Enter a short description of your task here (optional).

Steps

1. In the site, tap the AX PRO and then log in to the device (if required). 2. Tap → Communication Parameters→ Cellular Data Network Settings to enter the page. 3. Enable Cellular Data Network. 4. Tap Parameter Configuration → Edit Icon and set parameters including the user name, access

password, APN, MTU and PIN conde. 5. Tap Save Icon. 6. Enable Data Usage Limit. 7. Edit Data Used This Month and Data Limited per Month.

Push Notifications

When an alarm is triggered, if you want to send the alarm notification to the mobile phone, you can set the notification push parameters.

Steps

1. In the site, tap the AX PRO and then log in to the device (if required).

Page 34: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

33

2. Tap → Communication Parameters→ Push Notification(s) to enter the page. 3. Tap Phone Call and SMS. 4. Tap + or + Add Phone Number to enter the phone number. 5. Tap the added phone number to enable Phone Call and SMS according to your need. 6. (For Phone Call) Set Numbers of Calling. 7. (For SMS) Set Arming Permission, Disarming Permission and Alarm Clearing Permission for areas. 8. Check notifications.

Alarm Receiving Center (ARC)

You can set the alarm receiving center's parameters and all alarms will be sent to the configured alarm center.

Steps

1. In the site, tap the AX PRO and then log in to the device (if required). 2. Tap → Communication Parameters→ Alarm Receiving Center (ARC) to enter the page. 3. Select an ARC and enable it.

Zone Alarm/Lid Notification

The device will push notifications when the zone alarm is triggered or the zone lid opened is triggered or restored.

Note

You need to set event filtering interval time for phone calling.

Peripherals Lid Opened

The device will push notifications when lid opened of any peripherals is triggered or restored.

Panel Lid Opened

The device will push notifications when lid opened of the control panel is triggered or restored.

Panic Alarm

The device will push notifications when panic alarm is triggered or restored by zones, keypads or keyfobs.

Medical Alarm

The device will push notifications when medical alarm is triggered.

Gas Alarm

The device will push notifications when gas alarm is triggered.

Panel Status

The device will push notifications when the control panel system status is changed.

Zone Status

Page 35: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

34

The device will push notifications when the zone status is changed.

Peripherals Status

The device will push notifications when any peripheral status is changed.

Panel Operation

The device will push notifications when the user operates the AX PRO.

Smart Alarm Notification

The device will push notifications when the alarm is triggered in thermal cameras.

Device Maintenance

You can reboot the device.

Steps

1. In the site, tap the AX PRO and then log in to the device (if required). 2. Tap →Maintenance → Device Maintenance to enter the page. 3. Tap Test, and tap Start Walk Test to test the whether the device works properly or not. 3. Tap Maintenance → Reboot Device.

The AX PRO will reboot.

Device Management

Enter a short description of your concept here (optional).

This is the start of your concept.

Zone

You can set the zone parameters on the zone page.

Steps

1. In the site, tap the AX PRO and then log in to the device (if required). 2. Tap a zone in the Device tab. 3. Tap . 4. Tap Edit Icon to edit the zone name. 5. Select a zone type.

Instant Zone

This Zone type will immediately trigger an alarm event when armed.

Delayed Zone

Exit Delay: Exit Delay provides you time to leave through the defense area without alarm. Entry Delay: Entry Delay provides you time to enter the defense area to disarm the system without alarm. The system gives Entry/Exit delay time when it is armed or reentered. It is usually used in entrance/exit route (e.g. front door/main entrance), which is a key route to arm/disarm via

Page 36: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

35

operating keyboard for users.

Note

You can set 2 different time durations in System Options → Schedule & Timer. Ensure that timer is no longer than 45 seconds in order to comply with EN50131-1. If the zone is a delayed zone, you can set Enter delay/Exit delay parameters.

Follow Zone

The zone acts as delayed zone when it detects triggering event during system Entry Delay, while it acts as instant zone otherwise.

24h Silent Panic Zone

This zone type is active 24hrs, it is used for Panic or HUD (Hold Up Devices) not smoke sensors or break glass detectors.

Panic Zone

The zone activates all the time. It is usually used in the sites equipped with panic button, smoke detector and glass-break detector.

Fire Zone

The zone activates all the time with sound/sounder output when alarm occurs. It is usually used in fire hazardous areas equipped with smoke detectors and temperature sensors.

Gas Zone

The zone activates all the time with sound/sounder output when alarm occurs. It is usually used in areas equipped with gas detectors (e.g., the kitchen).

Medical Zone

The zone activates all the time with beep confirmation when alarm occurs. It is usually used in places equipped with medical emergency buttons.

Timeout Zone

The zone activates all the time. The zone type is used to monitor and report the "ACTIVE" status of a zone, but it will only report and alarm this status after the programmed time has expired. (1 to 599) Seconds. It can be used in places equipped with magnetic contacts that require access but for only a short period (e.g., fire hydrant box's door or another external security box door)

Key Zone

The linked area will arm after being triggered, and disarm after being restored. In the case of the tampering alarm, the arming and disarming operation will not be triggered.

Disabled Zone

Zone disabled ignoring any alarm event. It is usually used to disable faulty detectors. 6. Enable Stay Arm Bypass, Chime, Double Knock, Silent Alarm and other functions according to

your actual needs.

Page 37: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

36

Note

● Some zones do not support the function. Refer to the actual zone to set the function. ● Different zone types have different parameters.

7. Set the polling rate. 8. Optional: Tap Delete to delete the device.

Keypad

You can set the parameters of the keypad that is enrolled to the AX PRO.

Steps

1. In the site, tap the AX PRO and then log in to the device (if required). 2. Tap a keypad in the Device tab. 3. Tap . 4. Tap Edit Icon to edit the keypad name. 5. Enable Enable Keyfob. 6. Select linked users. 7. Tap Function Key Settings to set functions for single keys and combination keys. 8. Optional: Tap Delete to delete the device.

Sounder

The sounder is enrolled to the AX PRO via the wireless receiver module, and the 868 Mhz wireless sounder can be enrolled to the hybrid AX PRO via the wireless receiver that is at the address of 9.

Steps

1. In the site, tap the AX PRO and then log in to the device (if required). 2. Tap a sounder in the Device tab. 3. Tap . 4. Tap Edit Icon to edit the sounder name. 5. Select linked areas. 6. Set alarming lasting time and alarm volume. 7. Enable arming/disarming LED, arming/disarming buzzer, alarm indicator according to actual

needs. 8. Set heartbeat cycle. 9. Optional: Tap Delete to delete the device.

4.1.2 User the Hik-ProConnect Portal For AX Pro security control panel, you can perform operations including arming/disarming area, silence alarm, bypassing zone etc., and remotely configure the control panel on the Portal. You can also apply for PIN (required for upgrading the firmware of AX Pro) and switch the language of AX

Page 38: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

37

Pro.

Click Site to enter the site list page, and then click the name of a site to enter site details page.

Remotely Operate AX Pro

Click the AX Pro to open the operation panel. And you can perform the following operations.

Table 4-3 Operation Description

Operation Description

Stay Arm a Specific Area Select the Area tab, and then click Stay Arming to stay arm the area.

Away Arm a Specific Area Select the Area tab and then click Away Arming.

Disarm a Specific Area Select the Area tab and then click Disarm.

Stay Arm Multiple Areas Select the Area tab, and then select areas and click .

Away Arm Multiple Areas Select the Area tab, and then select areas and click .

Disarm Multiple Areas Select the Area tab, and then select areas and click .

Silence Alarms of Multiple Areas

Select the Area tab, and then select areas and click

Filter Peripheral Device by Area

Select the Device tab, and then click and select an area to only display the peripheral devices linked to the selected area, or select All to display all the peripheral devices linked to all the areas.

Control Relay Select the Device tab, and then select a wireless output expander to display the sirens linked to it, and then select siren(s) to enable/disable them.

Bypass Zone Select the Device tab, and then select a zone (i.e., detector) and turn on the Bypass switch to bypass the zone.

Page 39: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

38

Remotely Configure AX Pro

You can click to enter the web page of the security control panel to configure the device.

Note

For details about security control panel configuration, see the user manual of the device.

Apply for a PIN

You can click → to open the Apply for a PIN window, and then PIN code will be

Page 40: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

39

displayed.

Switch Language

Note

You should have applied for a PIN.

You can click → to open the Language window, and then set the device language and enter the PIN.

Health Monitoring

1. Enter the Hik-ProConnect Portal web site, and click Health Monitoring → Health Status to enter

Page 41: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

40

the page.

2. Select a site.

3. Click Health Check, and click Check Now. When checking is completed, you can view the status and reports of devices. You can also export the report.

4. Click to get the latest device status.

4.2 Set-up with Hik-Connect

The operator can use the Hik-Connect to control the device, such as general arming/disarming operation, and user management etc.

Page 42: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

41

Download and Login the Mobile Client

Download the Hik-Connect mobile client and login the client before operating the AX PRO.

Steps

1. Download Hik-Connect mobile client. 2. Optional: Register a new account if it is the first time you use the Hik-Connect mobile client.

Note

For details, see User Manual of Hik-Connect Mobile Client.

3. Run and login the client.

Add AX PRO to the Mobile Client

Add an AX PRO to the mobile client before other operations.

Steps

1. Power on the AX PRO. 2. Select adding type. Tap + → Scan QR Code to enter the Scan QR code page. Scan the QR code on the AX PRO.

Note

Normally, the QR code is printed on the label stuck on the back cover of the AX PRO.

Tap + → Manual Adding to enter the Add Device page. Enter the device serial No. with the Hik-Connect Domain adding type. 3. Tap to search the device. 4. Tap Add on the Results page. 5. Enter the verification code and tap OK. 6. After adding completed, enter the device alias and tap Save. 7. Optional: Tap → Delete to delete the device. 8. Optional: Tap → to edit the device name.

Add Peripheral to the AX PRO

Add peripheral to the AX PRO.

Steps

1. Select a control device (AX PRO). 2. Tap + .

– Tap Scan QR Code to enter the Scan QR code page. Scan the QR code on the peripheral. – Tap Manual Adding to enter the Add Device page. Enter the device serial No. and verification

code to add the device.

Page 43: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

42

Card/Tag Management

After adding cards/tags to the wireless AX PRO, you can swipe the card/tag to arm or disarm all the detectors added to specific area(s) of the AX PRO, and silence alarms.

Steps

1. On the device list page, tap the AX PRO and then log in to the device (if required) to enter the page.

2. Tap → User Management → Card/Tag to enter the page. 3. Tap + to add a card/tag. 4. When hearing the voice prompt "Swipe Tag", you should present the card/tag on the AX PRO

card/tag presenting area. ● When hearing a beep sound, the card/tag is recognized. ● The Tag will be displayed on the card/tag page.

5. Optional: Tap a card/tag to enter the Setting Page. 6. Tap to edit the Tag name.

Note

● If you log in as an installer, skip this step. Editing Tag name is only available to administrator. ● The name should contain 1 to 32 characters.

7. Slide Enable Card/Tag. 8. Select a linked user. 9. Select the tag type

Note

Different linked users have different tag permissions.

Operation Tag

You can swipe the tag to arm or disarm.

Patrol Tag

When you swipe the tag, the system will upload a record. 10. Optional: Tap Delete to delete the tag.

User Management

The administrator and the installers can manage users. If you are the administrator, you can add,

Page 44: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

43

edit, and delete users, and assign different permissions to the newly-added users.

Steps

Note

There are four types of users for the AX PRO, including administrator (or owner), operator, and installer (or setter). Different types of users have different permissions for accessing the functionality of the AX PRO.

1. On the device list page, tap the AX PRO and then log in to the device (if required) to enter the AX PRO page.

2. Tap to enter the Recipient Page. 3. Select a user to invite.

– Scan QR code to invite a user. – Enter email address/mobile phone number to invite a user. – Select a user in the list.

4. Tap Next to invite the user.

Note

The recipient need to accept the invitation.

5. Tap → User Management → User. 6. Tap a user to enter the User Management Page. 7. Optional: Perform the following operations if required.

User Permission You can tap the target user on the user list and then tap Edit Icon to set the permissions authorized to the target user.

Note

Only the administrator can do such an operation.

Set Linked Areas If the target user is an operator, tap the target user on the user list and then tap Linked Areas to set the area linked to the target user.

Note

Only the administrator can do such an operation.

Change Keypad Password

If the target user is an administrator, an installer or an operator, you can tap the target user on the user list and then tap Change Keypad Password to set the keypad password to the target user.

Page 45: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

44

Note

The password (PIN code) is allowed to be 4 to 6 digits. No number is disallowed, with 10,000 to 100,000 differs, and no limit of the digit combination. After you add one keypad, you can add PIN code (Keypad Password) in the user menu. When you click in the input box, there will be indication shows that 4 to 6 numbers allowed. This is the same for each user

Change Duress Password

If the target user is an administrator or an operator, you can tap the target user on the user list and then tap Change Duress Password to set the duress password to the target user.

Note

If under duress, you can enter the duress code on the keyboard to arm and disarm area(s) and upload a duress alarm.

Automation Control An administrator, an installer or an operator can control the relay module, wall switch and smart plug.

Note

● Configuration items and user permission will vary according to the user type. ● You can view linked Tags/tags and keyfobs of the user but you do not have permission to

configure them.

8. Optional: (Only for the administrator) Click + to add a user.

Bypass Zone

When the area is armed, you can bypass a particular zone as you desired.

Before You Start

Link a detector to the zone.

Steps

1. On the device list page, tap the AX PRO and then log in to the device (if required) to enter the Area page.

2. Tap Device. 3. Tap a zone in the Device tab. 4. Tap to enter the Setting page. 5. Enable Bypass and the zone will be in the bypass status.

Page 46: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

45

The detector in the zone does not detect anything and you will not receive any alarm from the zone.

Arm/Disarm the Area

Arm or disarm the area manually as you desired. On the device list page, tap the AX PRO and then log in to the device (if required) to enter the Area page.

Operations for a Single Area

● Away Arming: Tap to away arm a single area. When all the people in the detection area leave, turn on the Away mode to arm all zones in the area after the defined dwell time.

● Disarm: Tap Away Arming Icon in any area to disarm a single area. In Disarm mode, all the zones in the area will not trigger alarm, no matter alarm events happen or not.

Operations for All Areas

● Away: Tap to away arm all areas. When all the people in the detection area leave, turn on the Away mode to arm all zones in all areas after the defined dwell time.

● Stay: Tap to stay arm all areas. When the people stays inside the detection area, turn on the Stay mode to arm all the perimeter burglary detection (such as perimeter detector, magnetic contacts, curtain detector in the balcony) set in all the zones of all areas. At the meantime, the detectors inside the detection area are bypassed (such as PIR detectors). People can move inside the area and alarm will not be triggered.

● Disarm: Tap to disarm all areas. In Disarm mode, all the zones of all areas will not trigger alarm, no matter alarm events happen or not.

● Silence Alarm: Tap to silence alarms for all areas. Clear all the alarms triggered by the all the zones of all the areas.

Check Alarm Notification

When an alarm is triggered, and you will receive an alarm notification. You can check the alarm information from the mobile client.

Before You Start

● Make sure you have linked a zone with a detector. ● Make sure the zone is not bypassed. ● Make sure you have not enabled the silent zone function.

Steps

1. Tap Notification in the mobile client to enter the page. All alarm notifications are listed in Notification page.

2. Select an alarm and you can view the alarm details.

Page 47: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

46

3. Optional: If the zone has linked a camera, you can view the playback when the alarm is

triggered.

4. Optional: Tap to search events by dates or devices.

Wi-Fi Connection

You can make the AX PRO connect to Wi-Fi through APP.

Steps

1. On the device list page, tap the AX PRO and then log in to the device (if required) to enter the page.

2. Tap → Configure Wi-Fi Network. 3. Follow the instructions on the page and change the AX PRO to the AP mode. Tap Next. 4. Select a stable Wi-Fi for the device to connect. 5. Back to configuration page to enter the Wi-Fi password and tap Next.

Page 48: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

47

6. Tap Connect to a network and wait for connection. After the connection is completed, the AX PRO will prompt to exit AP mode and automatically switch to STA mode.

Device Maintenance

You can reboot the device.

Steps

1. On the device list page, tap the AX PRO and then log in to the device (if required) to enter the page.

2. Tap → Maintenance → Reboot Device. The AX PRO will reboot.

Page 49: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

48

4.3 Set-up with the Web Client

Steps

1. Connect the device to the Ethernet. 2. Search the device IP address via the client software and the SADP software. 3. Enter the searched IP address in the address bar.

Note

When using mobile browser, the default IP Address is 192.168.8.1. When connecting the network cable with computer directly, the default IP Address is

10.22.98.113.

4. Use the activation user name and password to login.

Note

Refer to Activation chapter for the details. Only the administrator and the installer can login to the web client.

You can view the user, device, and area status on the overview page.

Page 50: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

49

4.3.1 Communication Settings

Wired Network

You can set the device IP address and other network parameters.

Steps

Note

Functions varied depending on the model of the device.

1. Click Communication→ Wired Network to enter the page.

2. Set the parameters. Automatic Settings: Enable DHCP and set the HTTP port. Manual Settings: Disabled DHCP and set

IP Address, Subnet Mask, Gateway Address, DNS Server Address. 3. Optional: Set correct DNS server address if the device needs to visit Hik-Connect server via a

domain name. 4. Click Save.

Wi-Fi

You can set the Wi-Fi parameters if there are secure and credible Wi-Fi networks nearby.

Steps

1. Click Communication → Wi-Fi to enter the Wi-Fi page.

Page 51: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

50

2. Connect to a Wi-Fi. Manually Connect: Input the SSID Wi-Fi and Wi-Fi Password, select Encryption Mode and click Save. Select from Network List: Select a target Wi-Fi from the Network list. Click Connect and input Wi-Fi password and click Connect. 3. Click WLAN to enter the WLAN page.

4. Set IP Address, Subnet Mask, Gateway Address, and DNS Server Address.

Page 52: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

51

Note

If enable DHCP, the device will gain the Wi-Fi parameters automatically.

5. Click Save.

Cellular Network

Set the cellular network parameters if you insert a SIM card inside the device. By using the cellular network, the device can upload alarm notifications to the alarm center.

Before You Start

Insert a SIM card into the device SIM card slot.

Steps

1. Click Communication → Cellular Data Network to enter the Cellular Data Network Settings page.

2. Enable Wireless Dial. 3. Set the cellular data network parameters.

Access Number

Input the operator dialing number.

Page 53: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

52

Note

Only the private network SIM card user needs to enter the access number.

User Name

Ask the network carrier and input the user name.

Access Password

Ask the network carrier and input the password.

APN

Ask the network carrier to get the APN information and input the APN information.

Data Usage Limit

You can enable the function and set the data threshold every month. If data usage is more than the configured threshold, an alarm will be triggered and uploaded to the alarm center and mobile client.

Data Used This Month

The used data will be accumulated and displayed in this text box. 4. Click Save.

Alarm Center

You can set the alarm center's parameters and all alarms will be sent to the configured alarm center.

Steps

1. Click Communication → Alarm Receiving Center to enter the Alarm Receiving Center page.

Page 54: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

53

2. Select the Alarm Receiver Center as 1 or 2 for configuration, and slide the slider to enable the selected alarm receiver center.

Note

Only if the alarm receiver center 1 is enabled, you can set the alarm receiver center 2 as the backup channel and edit the channel parameters.

3. Select the Protocol Type as ADM-CID, ISUP, SIA-DCS, *SIA-DCS, or *ADM-CID to set uploading mode.

Note

Standard DC-09 Protocol ADM-CID: The data presenting method of DC-09 is CID, which is not encrypted and only for uploading alarm report. *ADM-CID: The data presenting method of DC-09 is CID, which is encrypted and only for uploading alarm report. SIA-DCS: The data presenting method of DC-09 is DCS (also called SIA protocol), which is not encrypted and only for uploading alarm report. *SIA-DCS: The data presenting method of DC-09 is DCS (also called SIA protocol), which is encrypted and only for uploading alarm report.

ADM-CID or SIA-DCS You should select the Alarm Receiver Type as IP or Domain name, and enter the IP/domain name, port number, account code, timeout, re-upload times and heartbeat interval.

Note

Set the heartbeat interval with the range from 10 to 3888000 seconds.

ISUP You do not need to set the ISUP protocol parameters. *SIA-DCS or *ADM-CID You should select the Alarm Receiver Type as IP or Domain name, and enter the IP/domain name, port number, account code, retry timeout period, attempts, heartbeat interval, encryption arithmetic, password length and secret key.

Note

Set the heartbeat interval with the range from 10 to 3888000 seconds. For encryption arithmetic: The panel support encryption format for information security according to DC-09, AES-128, AES-192 and AES-256 are supported when you configure the alarm center. For the secret key: When you use an encrypted format of DC-09, a key should be set when you configure the ARC. The key would be issued offline by ARC, which would be used to encrypt the message for substitution security.

3. Click Save.

Page 55: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

54

Note

You can enable the PIRCAM function to upload pictures or videos. 1. Upload Pictures

You can choose to upload 1 to 20 pictures.

(1) Click Communication → Alarm Receiving Center to enter the Alarm Receiving Center

page. (2) Slide the slider to enable the selected alarm receiver center. (3) Select the Protocol Type as SIA-DCS. (4) Select the Companies as French Alarm Receiving Company. (5) Click Save.

(6) Configure SMTP or FTP parameters.

Configure SMTP parameters: Click Communication → Notification by Email. Enable Video Verification Events and set corresponding parameters. For details, see Notification by Email. Click Save.

Page 56: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

55

Configure FTP parameters:

Click Communication → FTP to enter the FTP Settings page.

Slide the slider to enable FTP and set corresponding parameters. For details, see FTP. Click Save.

2. Upload Videos

In this condition, when the PIRCAM is set to catch more than two pictures, videos will be uploaded.

(1) Click Communication → Alarm Receiving Center to enter the Alarm Receiving Center page.

(2) Slide the slider to enable the selected alarm receiver center. (3) Select the Protocol Type as SIA-DCS. (4) Click Save. (5) Configure SMTP or FTP parameters as same as Upload Photos.

Notification Push

When an alarm is triggered, if you want to send the alarm notification to the client, alarm center, cloud or mobile phone, you can set the notification push parameters.

Steps

1. Click Communication → Event Types Notification.

Page 57: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

56

2. Enable the target notification.

Note

If you want to send the alarm notifications to the mobile client, you should also set the Mobile Phone Index, Mobile Phone Number, and check the Notification Type.

Note

For message notification in alarm receiving center, select the center index before settings.

3. Click Save.

Page 58: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

57

Result

Table 4-1 Options of Notifications

Option Notification

iVMS-4200

Zone alarm & Lid Opened

Wireless Device Lid Opened

Tamper Notification

Panic Alarm Notification

Medical Alarm Notification

Gas Alarm Notification

Fire Alarm Notification

Panel Management Notification

System Status Notification

Detector Status Notification

Wireless Device Status Notification

Alarm Receiver Center

Alarm Receiver Center 1&2

Zone alarm & Lid Opened

Wireless Device Lid Opened

Tamper Notification

Panic Alarm Notification

Medical Alarm Notification

Gas Alarm Notification

Fire Alarm Notification

Panel Management Notification

System Status Notification

Detector Status Notification

Wireless Device Status Notification

Cloud

Zone alarm & Lid Opened

Wireless Device Lid Opened

Tamper Notification

Panic Alarm Notification

Medical Alarm Notification

Page 59: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

58

Option Notification

Gas Alarm Notification

Fire Alarm Notification

Panel Management Notification

System Status Notification

Detector Status Notification

Wireless Device Status Notification

Mobile Phone

Mobile Phone Index 1 to 8

Mobile Phone Number

Notification Type SMS & Voice Call Check Box

Zone alarm & Lid Opened (Set Filter Time)

Number of Calls

Wireless Device Lid Opened

Tamper Notification

Panic Alarm Notification

Medical Alarm Notification

Gas Alarm Notification

Fire Alarm Notification

Panel Management Notification

System Status Notification

Detector Status Notification

Wireless Device Status Notification

Note

For mobile phone notification: You need to press * to finish the call. It is required to add control code when entering the mobile phone number.

Cloud Service

If you want to register the device to the mobile client for remote configuration, you should set the

Page 60: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

59

mobile client registration parameters.

Before You Start

● Connect the device to the network via wired connection, dial-up connection, or Wi-Fi connection.

● Set the device IP address, subnet mask, gateway and DNS server in the LAN.

Steps

1. Click Communication →Cloud Service to enter the Hik-Connect Registration Settings page.

2. Check Register to Hik-Connect.

Note

By default, the device Hik-Connect service is enabled.

You can view the device status in the Hik-Connect server (www.hik-connect.com). 3. Enable Custom Server Address.

The server address is already displayed in the Server Address text box. 4. Select a communication mode from the drop-down list according to the actual device

communication method.

Auto

The system will select the communication mode automatically according to the sequence of, wired network, Wi-Fi network, and cellular data network. Only when the current network is disconnected, will the device connect to other network.

Wired Network & Wi-Fi Priority

The connection priority order from high to low is: wired network, Wi-Fi, cellular data network.

Wired &Wi-Fi

Page 61: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

60

The system will select wired network first. If no wired network detected, it will select Wi-Fi network.

Cellular Data Network

The system will select cellular data network only. 5. Optional: Change the authentication password.

Note

● By default, the authentication password is displayed in the text box. ● The authentication password should contain 6 to 12 letters or digits. For security reasons, an

8-character password is suggested, which containing two or more of the following character types: uppercases, lowercases, and digits.

6. Click Save.

Notification by Email

You can send the alarm video or event to the configured email.

Steps

1. Click Communication →Notification by Email to enter the page. 2. Click the block to enable the function of sending video verification event. 3. Enter the sender's information.

Note

It is recommended to use Gmail and Hotmail for sending mails. Only if the zone is linked with a network camera, the alarm email will be attached with alarm video.

4. Enter the receiver's information. 5. Click Receiver Address Test and make sure the address is correct. 6. Click Save.

NAT

Universal Plug and Play (UPnP™) is a networking architecture that provides compatibility among networking equipment, software and other hardware devices. The UPnP protocol allows devices to connect seamlessly and to simplify the implementation of networks in the home and corporate environments.

Enable the UPnP function, and you don’t need to configure the port mapping for each port, and the device is connected to the Wide Area Network via the router.

Steps

1. Click Communication → NAT to enter the page.

Page 62: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

61

2. Drag the slider to enable UPnP. 3. Optional: Select the mapping type as Manual 4. Set the HTTP port and the service port. 5. Click Save to complete the settings

FTP

You can configure the FTP server to save alarm video.

Steps

1. Click Communication→ FTP to enter the page. 2. Configure the FTP parameters

FTP Type

Set the FTP type as preferred or alternated.

FTP Protocol

FTP and SFTP are selectable. The files uploading is encrypted by using SFTP protocol.

Server Address and Port

The FTP server address and corresponding port.

User Name and Password

The FTP user should have the permission to upload pictures. If the FTP server supports picture uploading by anonymous users, you can check Anonymous to hide your device information during uploading.

Directory Structure

The saving path of snapshots in the FTP server.

Page 63: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

62

4.3.2 Device Management

You can manage the enrolled peripherals including detector, sounder, keypad, etc. in this section.

Zone

You can set the zone parameters on the zone page.

Steps

1. Click Device → Zone to enter the Zone page.

2. Select a zone and click Edit Zone to enter the Zone Settings page.

3. Edit the zone name. 4. Check linked areas.

Note

Only enabled areas will be listed. The newly added peripheral is linked to area 1 by default.

5. Select a zone type.

Page 64: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

63

Instant Zone

This Zone type will immediately trigger an alarm event when armed.

Delay Zone

Exit Delay: Exit Delay provides you time to leave through the defense area without alarm. Entry Delay: Entry Delay provides you time to enter the defense area to disarm the system without alarm. The system gives Entry/Exit delay time when it is armed or reentered. It is usually used in entrance/exit route (e.g. front door/main entrance), which is a key route to arm/disarm via operating keyboard for users.

Note

You can set 2 different time durations in System Options → Schedule & Timer. Ensure that timer is no longer than 45 seconds in order to comply with EN50131-1. You can set Stay Arm Delay Time for the delay zone.

Panic Zone

The zone activates all the time. It is usually used in the sites equipped with panic button, smoke detector and glass-break detector.

Keyswitch Zone

The linked area will arm after being triggered, and disarm after being restored. In the case of the tampering alarm, the arming and disarming operation will not be triggered.

Note

Two trigger types (by trigger times and by zone status) can be selected for the zone. If the zone status type is selected, set the trigger operation (trigger arming/disarming).

Disabled Zone

Zone disabled ignoring any alarm event. It is usually used to disable faulty detectors.

24 Hours Zone

The zone activates all the time with sound/siren output when alarm occurs. It is usually used in fire hazardous areas equipped with smoke detectors and temperature sensors.

6. Enable Cross zone, Silent Alarm, etc. according to your actual needs.

Note

Some zones do not support the function. Refer to the actual zone to set the function.

7. Set the Sounder Delay Time. The sounder will be triggered immediately or after the set time. 8. If required, link a camera for the zone. 9. Click OK.

Page 65: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

64

Note

After setting the zone, you can enter Maintenance → Device Status → Zone Status to view the zone status.

Sounder

The sounder is enrolled to the AX PRO via the wireless receiver module, and the 868 Mhz wireless sounder can be enrolled to the hybrid AX PRO via the wireless receiver that is at the address of 9.

Steps

1. Click Device → Sounder to enter the Sounder page. 2. Click to enter the Sounder Settings page.

Page 66: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

65

3. Set the sounder name and the volume.

Note

The available sounder volume range is from 0 to 3 (function varies according to the model of device).

4. Enable Enroll Wireless Sounder and set the sounder serial No. 5. Select the linked area.

Note

Only enabled areas will be listed. The newly added peripheral is linked to area 1 by default.

6. Select to enable Alarm LED Indicator, Alarm Buzzer, Arm/Disarm LED Indicator, and Arm/Disarm Buzzer.

7. Set the Polling Rate and Alarm Duration. 8. Click OK.

Note

After the sounder is configured, you can click Maintenance → Device Status → Sounder Status to view the sounder status.

Keypad

You can set the parameters of the keypad that is enrolled to the AX PRO.

Steps

1. Click Device → Keypad to enter the page. 2. Click to enter the Keypad Settings page.

Page 67: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

66

3. Set the keypad name. 4. Check the check box to enable the function of buzzer, silent panic alarm, silent medical alarm,

and keypad button. 5. Check the check box to enable the function of arming without password. 6. Check the Enable check box of Back-light Off Time, and set the duration of light off. 7. Set the polling rate. 8. Select the keypad linked area.

Note

Only enabled areas will be listed. The newly added peripheral is linked to area 1 by default.

9. Set whether to cancel the enrollment of the keypad or not. If the link is enabled, the device will be deleted.

10. Click OK.

Page 68: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

67

Note

● After the keypad is configured, you can click Maintenance → Device Status → Keypad Status to view the keypad status.

● You can set the keypad password on the page of User → User Management→ Operation.

Automation

You can set the parameters of the relay outputs that is enrolled to the AX PRO.

Steps

1. Click Device → Automation to enter the page. 2. Click Enroll, enter the serial No. and select the device type to add a relay output device.

3. Click to edit the relay information.

Page 69: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

68

Set the name of the relay output device. Select the linked area for output.

Note

Only enabled areas will be listed. The newly added peripheral is linked to area 1 by default. The function varies according to different relay types

Set the original status as Normally Closed or Normally Opened. Set the Polling rate. Set whether to protect voltage/current or not. Set the event for being triggered. Set the activation after being triggered. Set whether to link to the relay output device or not. If the link is enabled, the device will be

deleted.

Repeater

The repeater can amplify signals between the control panel and the peripherals.

Steps

1. Click Device →Repeater to enter the page. 2. Click Enroll, enter the serial No. and select the device type to add a repeater. 3. Click Enter Paring Mode to make the repeater enter the mode of device paring. 4. When the distance between the peripheral and the control panel is far, the repeater can be used

as a transfer station for pairing. The pairing mode lasts for 3 minutes and cannot be interrupted. After the pairing is successful, a list of connected devices will be displayed.

5. Click to edit the repeater information.

Page 70: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

69

Set the name of the repeater. Set the polling rate of the repeater. Set whether to cancel the enrollment of the repeater or not. If the link is enabled, the device

will be deleted.

Network Camera

You can add network cameras in the system.

Steps

1. Click Device → Camera to enter the page. 2. Click Enroll, enter the IP address. user name and password to add a camera.

3. Click to edit the camera information.

Page 71: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

70

You can also click to edit the camera, or click to delete the camera.

4.3.3 Area Settings

Basic Settings

You can link zones to the selected area.

Steps

1. Click Area → Basic Settings to enter the page. 2. Select an area. 3. Check Enable. 4. Check the check box in front of the zone to select zones for the area. 5. Click Save to complete the settings.

Schedule and Timer Settings

You can set the alarm schedule. The zone will be armed/disarmed according to the configured time schedule.

Steps

1. Click System→ System Options → Schedule & Timer to enter the Schedule & Timer page. 2. Select an area. 3. Set the following parameters according to actual needs.

Page 72: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

71

Enable Auto Arm

Enable the function and set the arming start time. The zone will be armed according to the configured time.

Note

● The auto arming time and the auto disarming time cannot be the same. ● The buzzer beeps slowly 2 minutes before the auto arming starts, and beeps rapidly 1

minute before the auto arming starts. ● You can select to enable forced arming on the System Options page. While the function is

enabled, the system will be armed regardless of the fault. ● If the public area is enabled, the area 1 does not support auto arming.

Enable Auto Disarm

Enable the function and set the disarming start time. The zone will be disarmed according to the configured time.

Note

● The auto arming time and the auto disarming time cannot be the same. ● If the public area is enabled, the area 1 does not support auto disarming.

Late to Disarm

Enable the function and set the time. If the alarm is triggered after the configured time, the person will be considered as late.

Note

You should enable the Panel Management Notification function in Communication Parameters → Event Communication before enabling the Late to Disarm function.

Weekend Exception

Enable the function and the zone will not be armed in the weekend.

Holiday Exception

Enable the function and the zone will not be armed/disarmed in the holiday. You should set the holiday schedule after enabling.

Note

Up to 6 holiday groups can be set.

Panel Alarm Duration

The time duration of the panel alarm.

Page 73: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

72

Note

The available time duration range is from 10 s to 900 s.

5. Click Save.

4.3.4 Video Management

You can add two network cameras to the AX PRO, and link the camera with the selected zone for video monitoring. You can also receive and view the event video via client and Email.

Add Cameras to the AX PRO

Steps

1. Click Device →Network Camera to enter the network camera management page.

2. Click Enroll, and enter the basic information of the camera, such as IP address and port No., and

select the protocol type. 3. Enter the user name and password of the camera. 4. Click OK . 5. Optional: Click Edit or Delete to edit or delete the selected camera.

Link a Camera with the Zone

Steps

1. Click Device → Zone to enter the configuration page. 2. Select a zone that you wish to include video monitoring, and click the . 3. Select the Panel Video Channel No.. 4. Click OK.

Page 74: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

73

Note

Only if the zone is linked with a network camera, the alarm email will be attached with alarm video.

Set Video Parameters

Steps

1. Click Device → Network Camera → Video Parameters to enter the page.

2. Select a camera and set the video parameters.

Stream Type

Main Stream: Being used in recording and HD preview, it has a high resolution, code rate and picture quality. Sub-Stream: It is used to transmit network and preview pictures as a video streaming with features of lower resolution, bit rate and picture quality.

Bitrate Type

Select the Bitrate type as constant or variable.

Resolution

Select the resolution of the video output.

Video Bitrate

The higher value corresponds to the higher video quality, but the better bandwidth is required.

Page 75: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

74

4.3.5 Permission Management

Add/Edit/Delete Keyfob

You can add keyfob to the AX PRO and you can control the AX PRO via the keyfob. You can also edit the keyfob information or delete the keyfob from the AX PRO.

Steps

1. Click Device → Keyfob to enter the Keyfob Management page. 2. Click Enroll and press any key on the keyfob. 3. Set the keyfob parameters.

Name

Customize a name for the keyfob.

Permission Settings

Check different items to assign permissions.

Single Key Settings

Select from the drop-down list to set I key and II key's functions

Combination Keys Settings

Select from the drop-down list to set combination keys' functions.

4. Click OK. 5. Optional: Click to edit the keyfob information. 6. Optional: Delete a single keyfob or check multiple keyfobs and click Delete to delete the keyfobs

in batch.

Note

The communication of wireless devices like keyfob was identified by the SN number, which will be encrypted during transmission. The SN number was leading with character Q to Z, and following 8 digits, like Q02235774.Allowing for a maximum number of 100,000,000 (10 to the power of 8 [digits]).

Add/Edit/Delete Tag

You can add tag to the AX PRO and you can use the Tag to arm/disarm the zone. You can also edit the tag information or delete the tag from the AX PRO.

Note

The communication of tag was identified by the SN number, which will be encrypted during

transmission. The SN number was leading with 32 digits, and there are at most 4,294,967,296 SN

numbers can be identified.

Page 76: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

75

Steps

1. Click Device → Tag to enter the management page. 2. Click Enroll and place a Tag on the Tag area of the AX PRO. 3. Customize a name for the Tag in the pop-up window. 4. Select the Tag type and Tag linked area. 5. Select the permission for the Tag.

Note

You should allocate at least a permission for the Tag.

6. Click OK and the tag information will be displayed in the list.

Note

The Tag supports at least 20-thousand serial numbers.

7. Optional: Click and you can change the Tag name. 8. Optional: Delete a single Tag or check multiple Tags and click Delete to delete Tags in batch.

4.3.6 Maintenance

Test

The AX PRO supports walk test function.

Steps

1. Enter Maintenance → Device Maintenance →Test → to enable the function.

Page 77: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

76

Note

Only when all the detectors are without fault, you can enter the mode TEST mode.

2. Check the Test check box to start walk test. 3. Click Save to complete the settings. 4. Trigger the detector in each zone. 5. Check the test result.

Export File

You can export debugging file to the PC.

Steps

1. Click Maintenance → Device Maintenance → Export File to enter the page.

Page 78: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

77

2. Check the check box to enable the function. 3. Click Export to save the debugging file in the PC.

4.3.7 System Settings

Authority Management

Set the authority options. Click System → System Options → System Management to enter the System Option Management page.

Page 79: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

78

Forced Auto Arm

If the option is enabled and there are active faults in a zone, the zone will be bypassed automatically when arming.

Note

You should disable the arming function in the Advanced Settings page. Or the AX PRO arming with fault function cannot be valid.

System Status report

If the option is enabled, the device will upload report automatically when the AX PRO status is changed.

Voice Prompt

If the option is enabled, the AX PRO will enable the text voice prompt.

System Volume

The available system volume range is from 0 to 10.

Audible Tamper Alarm

While enabled, the system will alert with buzzer for the tamper alarm.

Panel Lockup Button

Enable/disable the lockup button for the control panel.

Bypass on Re-arm

While enabled, the zone with fault will be bypassed automatically when re-arming.

Polling Loss Times

Set the maximum duration for polling loss. The system will report fault if the duration is over the limit.

Fault Check

The system determines whether to check the faults listed on the page. The system will only check the fault that is selected. Click System → System Options → Panel Fault Check to enter the page.

Page 80: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

79

Detect Network Camera Disconnection

If the option is enabled, when the linked network camera is disconnected, an alarm will be triggered.

Battery Fault Check

If the option is enabled, when battery is disconnected or out of charge, the device will upload events.

LAN Fault Check

If the option is enabled, when the wired network is disconnected or with other faults, the alarm will be triggered.

Wi-Fi Fault Check

If the option is enabled, when the Wi-Fi is disconnected or with other faults, the alarm will be triggered.

Cellular Network Fault Check

If the option is enabled, when the cellular data network is disconnected or with other faults, the alarm will be triggered.

AC Power Loss Delay

The system checks the fault after the configured time duration after AC power down. To compliant the EN 50131-3, the check time duration should be 10 s.

Arm Options

Set advanced authority parameters. Click System → System Options →Arm Options to enter the Advanced Settings page.

Page 81: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

80

You can set the following parameters:

Enable Arming with Fault

Check the faults in the Enable Arming with Fault list, and the device will not stop the arming procedure when faults occurred.

Fault Checklist

The system will check if the device has the faults in the checklist during the arming procedure.

Enable Early Alarm

If you enable the function, when the zone is armed and the zone is triggered, the alarm will be triggered after the set delay time.

Note

The early alarm will be taken effect only after the delayed zone is triggered.

Device Enroll Mode

Click Enter the Enrollment Mode to make the panel enter the enroll mode.

Page 82: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

81

Time Settings

You can set the device time zone, synchronize device time, and set the DST time. The device supports time synchronization via Hik-Connect Guarding Vision server.

Time Management

Click System → System Settings → Time to enter the Time Management page.

You can select a time zone from the drop-down list. You can synchronize the device time manually with NTP. Check the check box of NTP Time Sync., enter the server address and port No., and set the synchronization interval. You can synchronize the device time manually. Or check Sync. with Computer Time to synchronize the device time with the computer time.

Note

While you synchronize the time manually or with the computer time, the system records the log “SDK Synchronization”.

DST Management

Click System → System Settings → DST Management to enter the Time Management page.

You can enable the DST and set the DST bias, DST start time, and DST end time.

Page 83: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

82

Security Settings

SSH Settings

Enable or disable SSH (Secure Shell) according to your actual needs. Click System → System Security→ SSH Settings to enter the SSH Settings page and you can enable or disable the SSH function.

Locking User Settings

The device will be locked 90 s after 3 failed credential attempts (can be set in Retry Time before Auto-Lock) in a minute. You can view the locked user or unlock a user and set the user locked duration.

Note

To compliant the EN requirement, the system will only record the same log 3 times continuously.

Steps

1. Click System → System Security → User Lockout Attempts to enter the Locking User Settings page.

Page 84: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

83

2. Set the following parameters.

Retry Times before Auto-Lock

If the user continuously input the incorrect password for more than the configured times, the account will be locked.

Note

The administrator has two more attempts than the configured value.

Locked Duration

Set the locking duration when the account is locked.

Note

The available locking duration is 5s to 1800s.

3. Click to unlock the account or click Unlock All to unlock all locked users in the list. 4. Click Save.

Module Lock Settings

Set the module locking parameters, including the Max Failure Attempts, and locked duration. The

Page 85: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

84

module will be locked for the programmed time duration, once the module authentication has failed for the amount of configured times.

Steps

1. Click System → System Security → Module Locking Settings to enter the Module Lock Settings page.

2. Select a module from the list, and click the icon. 3. Set the following parameters of the selected module.

Max. Failure Attempts

If a user continuously tries to authentication a password for more than the configured attempts permitted, the keypad will be locked for the programmed duration.

Locked Duration

Set the locking duration when the keypad is locked. After the configured duration, the keypad will be unlocked.

4. Click OK. 5. Optional: Click the Lock icon to unlock the locked module.

System Maintenance

You can reboot the device, restore default settings, import/export configuration file, or upgrade the device remotely. Select the device and click in the client software, or enter the device IP address in the address bar of the web browser. Click Maintenance→ Device Maintenance→ Maintenance to enter the Upgrade and Maintenance page.

Page 86: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

85

Reboot

Click Reboot to reboot the device.

Restore Default Settings

Click Partly Restore to restore all parameters except for admin user information, wired network, Wi-Fi network, detector information, and peripheral information to default ones. Click Restore All to restore all parameters to the factory settings.

Import Configuration File

Click View to select configuration file from the PC and click Import Configuration File to import configuration parameters to the device. Importing configuration file requires entering the password set at the time of exporting.

Export Configuration File

Click Export Configuration File to export the device configuration parameters to the PC. Exporting configuration file requires a password to be used for file encryption.

Export File

Click Maintenance → Device Maintenance → Export File Enable Debugging Log to enable the function.

Page 87: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

86

Select file type needs to be exported. Click Export to export the file.

Local Log Search

You can search the log on the device. Click Maintenance→ Log to enter the Local Log Search page.

Select a major type and a minor type from the drop-down list, set the log start time and end time and click Filter. All filtered log information will be displayed in the list. You can also click Reset to reset all search conditions.

Page 88: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

87

Device Upgrade

Get Manufacture PIN

To upgrade the device, a manufacture PIN is needed for authentication. The manufacture PIN can only get from the Hik-ProConnect service, which means that the installer, who authorized by administrator at access level 2, has authorized the access at level 4. The manufacture PIN can only work once. Get PIN from Hik-ProConnect Service

Login with the installer account and enter the page of the device to be upgraded. Click More Menu at the lower right side of the page, and apply a PIN.

Get PIN from HIKVISION tech-support

It is better to use remote desktop to access the local web client of control panel. The PIN

Page 89: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

88

will be authorized according to the standard tech-support procedure.

Firmware Upgrade

Steps: 1. Click Maintenance→ Device Information to enter the page. 2. Click Remote Upgrade.

3. Enter the manufacture PIN to open the upgrade interface.

4. Click View to find the firmware file with the name digicap.dav. 5. Click Upgrade to complete.

Page 90: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

89

Note

Both of the users and configuration information will be retained after upgrade finished.

4.3.8 Check Status

After setting the zone, repeater, and other parameters, you can view their status. Click Maintenance → Device Status. You can view the status of zone, relay, sounder, keypad, Tag reader, battery, and communication.

● Zone: You can view the zone status, alarm status, detector battery capacity, and signal strength. ● Sounder: You can view sounder status, battery status, and signal strength. ● Output: You can view relay status, battery status, and signal strength. ● Keypad: You can view keypad status, battery status, and signal strength. ● Repeater: You can view repeater working status.

Page 91: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

90

● Tag Reader: You can view Tag reader status, battery status, and signal strength. ● Transmitter: You can view Transmitter status, battery status, and signal strength.

4.4 Report to ARC (Alarm Receiver Center) AX Pro wireless control panel is designed with transceiver built in following the guidance of EN 50131-10 and EN 50136-2. Category DP2 is provided with primary network interface of LAN/WiFi and secondary network interface of GPRS or 3G/4G LTE. ATS (Alarm Transmission system) is designed to always use LAN/Wi-Fi network interface when available to save mobile data usage. The secondary network interface provides resilience and reliability during mains power failure. Setup ATS in Transceiver of Receiving Center

Steps: 1. Login to the web client of the alarm receiver.

2. Click Configuration→ IP Reception, and create a receiving server as shown below.

3. Click Alarms and Accounts→ Accounts Management, and assign an account for the panel as show below.

Page 92: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

91

Setup ATS in Transceiver of the Panel Steps:

1. Login using installer account from local web client.

2. Click Communication→ Alarm Receiving Center (ARC), and enable Alarm Receiving Center 1.

= Protocol Setting =

Protocol Type — ADM-CID

— SIA-DCS

— *ADM-CID

— *SIA-DCS

Select token supported by the receiver in the ARC. Choose the token with “*” mark to

improve the communication security.

Page 93: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

92

= Server Setting =

Address Type — IP

— Domain Name

Server Address / Domain Name

Port No. Input IP address or domain name by which the transceiver of receiving center could be

reached. Input port number of the server provided by the ARC

= Account Setting =

Account Code Input the assigned account provided by the ARC.

= SIA DC-09 Protocol Setting =

Transmission Mode — TCP

— UDP

Both TCP and UDP are supported for transmission. UDP is recommended by the SIA DC-09

standard.

Connection Setting ○ Impulse Counting Time / Retry Timeout Period

Setup the timeout period waiting for receiver to respond. Re-transmission will be

arranged if the transceiver of receiving center is timeout.

○ Attempts Setup the maximum number that re-transmission will be tried.

○ Polling Rate Setup the interval between 2 live polling if enable is checked.

Encryption Setting ○ Encryption Arithmetic

— AES

○ Password Length — 128

— 192

— 256

○ Secret Key Setup the encryption key length and input the key provided by the ARC.

Signaling Test Activate a panic alarm from the control panel.

Page 94: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

93

Login to Receiver. Click Traffic to review all the messages received.

Page 95: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

94

Chapter 5 General Operations

5.1 Arming

You can use keypad, keyfob, Tag, client software, mobile client to arm your system. After the arming command is sending to AX PRO, the system will check the detector status. If the detector is in fault, you will need to choose whether to arm the system with fault. While the system is armed, the AX PRO will prompt the result in 5s, and upload the arming report.

Access level of Arming

The user in level 2 or 3 has the permission to arm or partly arm the system.

Arming Indication

The arming/disarming indicator keeps solid blue for 5s.

Reason of Arming Failure

● Intrusion detector triggered (excepts the detector on the exit route). ● Panic alarm device triggered. ● Tampering alarm occurred. ● Communication exception ● Main power supply exception

Page 96: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

95

● Backup battery exception ● Alarm receiving fault ● Sounder fault ● Low battery of the keyfob ● Others

Arming with Fault

While the arming is stopped with fault, user in level 2 has the permission to arm the system with fault (forced arming). Forced arming only takes effect on the current arming operation. The forced arming operation will be record in the event log.

5.2 Disarming

You can disarm the system with keypad, keyfob, Tag, client software, or mobile client.

Disarming Indication

The arming/disarming indicator flashes 30s while the user successfully disarm the system through the entry/exit route. The system will report the disarming result after the operation completed.

Entry Delay Duration

Ensure that timer is no longer than 45 seconds in order to comply with EN50131-1.

Early Alarm

If either the intrusion or tampering alarm occurs on the enter/exit route when the AX PRO is in the status of entry delay, the AX PRO then enters the early alarm mode. The early alarm duration can be set (> 30s). The AX PRO will reports the alarm only if the alarm event lasts over the duration of early alarm with the addition of entry delay.

5.3 SMS Control

You can control the security system with SMS, and the command is shown below. SMS format for Arming/disarming/silencing alarm:

{Command} + {Operation Type} + {Target} Command: 2 digits, 00- Disarming, 01- Away arming, 02- Stay arming, 03- Silencing alarm Operation type: 1- Area Operation Target: No more than 3 digits, 0-Operation for all areas, 1-Operation for area 1(zone1), and the rest can be deduced by the analogy.

Page 97: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

96

A. Trouble Shooting

A.1 Communication Fault

A.1.1 IP Conflict

Fault Description: IP that the panel automatically acquired or set is same as other devices, resulting in IP conflicts. Solution: Search the current available IP through ping. Change the IP address and log in again.

A.1.2 Web Page is Not Accessible

Fault Description: Use browser to access web pages and display Inaccessible. Solutions: 1. Check whether the network cable is loose and the panel network is abnormal. 2. The panel port has been modified. Please add a port to the web address for further access.

A.1.3 Hik-Connect is Offline

Fault Description: The web page shows that the Hik-Connect is offline. Solution: Network configuration of the panel is error, unable to access extranet.

A.1.4 Network Camera Drops off Frequently

Fault Description: System reports multiple event logs of IPC disconnection and connection. Solution: Check whether the network communication or camera live view is proper.

A.1.5 Failed to Add Device on APP

Fault Description: When using APP to add devices, it is prompted that the device fails to be added, the device could not be found, etc. Solution:

Page 98: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

97

Check the web page: whether the Hik-Connect is offline.

A.1.6 Alarm Information is Not Reported to APP/4200/Alarm Center

Fault Description: After the alarm is triggered, the app/4200/ alarm center does not receive the alarm message. Solution: "Message push" - "alarm and tamper-proof notice" is not enabled. You should enable "alarm and tamper-proof notice".

A.2 Mutual Exclusion of Functions

A.2.1 Unable to Enter Registration Mode

Fault Description: Click the panel function key, and prompt key invalid. Solution: The panel is in "Hotspot" mode. Switch the panel to "station" mode, and then try to enter the registration mode again.

A.3 Zone Fault

A.3.1 Zone is Offline

Fault Description: View status of zones which displays offline. Solution: Check whether the detector reports undervoltage. Replace the detector battery

A.3.2 Zone Tamper-proof

Fault Description: View status of zones which displays tamper-proof. Solution: Make tamper-proof button of the detector holden.

A.3.3 Zone Triggered/Fault

Fault Description:

Page 99: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

98

View status of zones which displays triggered/fault. Solution: Reset the detector.

A.4 Problems While Arming

A.4.1 Failure in Arming (When the Arming Process is Not Started)

Fault Description: When the panel is arming, prompt arming fails. Solution: The panel does not enable "forced arming", and when there is a fault in the zone, the arming will fail. Please turn on the "forced arming" enable, or restore the zone to the normal status.

A.5 Operational Failure

A.5.1 Failed to Enter the Test Mode

Fault Description: Failed to enable test mode, prompting "A fault in the zone". Solution: Zone status, alarm status or zone power is abnormal.

A.5.2 The Alarm Clearing Operation on the Panel Does Not Produce the Alarm Clearing Report

Fault Description: The alarm clearing operation on the panel does not produce the alarm clearing report. Solution: In the absence of alarm, no report will be uploaded for arm clearing.

A.6 Mail Delivery Failure

A.6.1 Failed to Send Test Mail

Fault Description: when configure the mail information, click "test inbox" and prompt test fails.

Page 100: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

99

Solution: Wrong configuration of mailbox parameters. Please edit the mailbox configuration information, as shown in table 1/1.

A.6.2 Failed to Send Mail during Use

Fault Description: Check the panel exception log. There is "mail sending failure". Solution: The mailbox server has restricted access. Please log in to the mailbox to see if the mailbox is locked.

A.6.3 Failed to Send Mails to Gmail

Fault Description: The receiver's mailbox is Gmail. Click "Test Inbox" and prompt test fails. 1. Google prevents users from accessing Gmail using apps/devices that do not meet their security standards. Solution: Log in to the website (https://www.google.com/settings/security/lesssecureapps), and "start using access of application not safe enough". The device can send mails normally. 2. Gmail does not remove CAPTCHA authentication. Solution: Click the link below, and then click "continue" (https://accounts.google.com/b/0/displayunlockcaptcha).

A.6.4 Failed to Send Mails to QQ or Foxmail

Fault Description: The receiver's mailbox is QQ or foxmail. Click "Test Inbox" and prompt test fails. 1. Wrong QQ account or password. Solution: the password required for QQ account login is not the password used for normal login. The specific path is: Enter the email account → device → account → to generate the authorization code, and use the authorization code as the login password. 2. SMTP login permission is needed to open.

A.6.5 Failed to Send Mails to Yahoo

Fault Description: The receiver's mailbox is yahoo. Click "test inbox" and prompt test fails. 1. The security level of mailbox is too high. Solution: Go to your mail account and turn on "less secure sign-in".

Page 101: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

100

A.6.6 Mail Configuration

Table A-1 Mail Configuration

Mail Type Mail Server SMTP Port Protocols Supported

Gmail smtp.gmail.com 587 TLS/STARTTLS (TLS)

Outlook smtp.office365.com 587 STARTTLS (TLS)

Hotmail smtp.office365.com 587 STARTTLS (TLS)

QQ smtp.qq.com 587 STARTTLS (TLSv1.2)

Yahoo smtp.mail.yahoo.com 587 STARTTLS (TLSv1.2)

126 smtp.126.com 465 SSL/TLS

Sina smtp.sina.com 25/465/587 SSL/TLS/STARTTLS (SSL/TLS)

Note

About mail configuration: ● SMTP portDefault to use port 25 without encryption, or using port 465 if SSL/TLS is used.

Port 587 is mainly used for STARTTLS protocol mode. The STARTTLS protocol mode that is usually used by default when selecting TLS.

● User nameUser name of Outlook and Hotmail require full names, and other email require a prefix before @.

Page 102: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

101

B. Input Types

Table B-1 Input Types

Input Types Operations

Instant Zone

The system will immediately alarm when it detects triggering event after system armed.

Audible Response Trigger the system sound and sounder.

Voice Prompt: Zone X alarm.

Perimeter Zone

The system will immediately alarm when it detects triggering event after system armed.

Audible Response: Trigger the system sound and sounder. There is a configurable interval between alarm and sounder output, which allows you to check the alarm and cancel the sounder output during the interval.

Voice Prompt: Zone X perimeter alarm.

Delayed Zone

The system provides you time to leave through or enter the defense area without alarm.

Audible Response: Trigger the system sound and sounder.

Voice Prompt: Zone X alarm.

Follow Zone

The zone acts as delayed zone when it detects triggering event during system Entry Delay, while it acts as instant zone otherwise.

Audible Response: Trigger the system sound and sounder.

Voice Prompt: Zone X follow alarm.

24H Silence Zone

The zone activates all the time without any sound/sounder output when alarm occurs.

Audible Response: No system sound (voice prompt or sounder).

Panic Zone

The zone activates all the time.

Audible Response: Trigger the system sound and sounder.

Voice Prompt: Zone X panic alarm.

Fire Zone The zone activates all the time with sound/sounder output when alarm occurs.

Page 103: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

102

Input Types Operations

Audible Response: Trigger the system sound and sounder.

Voice Prompt: Zone X fire alarm.

Gas Zone

The zone activates all the time with sound/sounder output when alarm occurs.

Audible Response: Trigger the system sound and sounder.

Voice Prompt: Zone X gas alarm.

Medical Zone

The zone activates all the time with beep confirmation when alarm occurs.

Audible Response: Trigger the system sound and sounder.

Voice Prompt: Zone X medical alarm.

Timeout Zone

The zone activates all the time. The zone type is used to monitor and report the "ACTIVE" status of a zone, but it will only report and alarm this status after the programmed time has expired (1 to 599) seconds.

Disabled Zone

Alarms will not be activated when the zone is triggered or tampered.

Audible Response: No system sound (voice prompt or sounder).

Virtual Zone (Keypad/Keyfob)

The system will immediately alarm when it detects triggering event after system armed.

Audible Response: Trigger the system sound and sounder.

Voice Prompt: Buzzer beeps.

Tamper Alarm

The system will immediately alarm when it detects triggering event after system armed.

Audible Response: Trigger the system sound and sounder.

Voice Prompt: Zone X tampered.

Link

Trigger the linked device when event occurs.

e.g. The output expander linked relays will be enabled when the AX PRO is armed.

Arm

When armed: Voice prompt for fault. You can handle the fault according to the voice prompt.

● System sound for arming with Tag or keyfob. ● Voice prompt for fault. You can handle the fault according to

the voice prompt.

Page 104: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

103

Fault event displays on client. You can handle the fault via client software or mobile client.

Voice Prompt: Armed/Arming failed.

Page 105: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

104

C. Output Types

Table C-1 Output Types

Output Types Active Restore

Arming Arm the AX PRO After the configured output delay

Disarming Disarm the AX PRO After the configured output delay

Alarm

When alarm event occurs. The alarm output will be activated after the configured exit/enter delay.

After the configured output delay, disarm the AX PRO or silence alarm

Zone Linkage When alarm event occurs, the linked relay will output alarm signal.

After the configured output duration

Manual Operation Enable relays manually Over the triggering time or disable the relays manually

Page 106: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

105

D. Event Types

Table D-1 Event Types

Event Types Custom

Default 1 (client

software notification)

Default 2 (alarm

receiving center 1/2)

Default 3 (mobile client)

Default 4 (telephone)

Alarm and Tamper

×/√ √ √ √ √

Life Safety Event

×/√ √ √ √ √

System Status ×/√ √ × × ×

Panel Management

×/√ √ × × ×

Page 107: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

106

E. Access Levels

Level Description

1 Access by any person; for example the general public.

2 User access by an operator and administrator; for example customers (systems users).

3 User access by an installer; for example an alarm company professional.

Table E-1 Permission of the Access Level

Function Permission

1 2 3

Arming No Yes Yes

Disarming No Yes Yes

Restoring/Clearing Alarm No Yes Yes

Entering Walk Test Mode No Yes Yes

Bypass(zone)/Disabling/Force Arming No Yes Yes

Adding/Changing Verification Code No Yesd Yesd

Adding/Editing Level 2 User and Verification Code

No Yes Yes

Adding/Editing Configuration Data No No Yes

Replacing software and firmware No No No

Note a By the condition of being accredited by user in level 2. bBy the condition of being accredited by user in level 2 and level 3. dUsers can only edit their own user code.

● The user level 2 can assign the login permission of the controller to the user level 3 in the settings page.

● The user level 2 should assign permissions to the user level 3 if the user level 3 wants to login the controller remotely.

● When the controller is bypassed, the user level 3 can login the controller without the permission assignment of the user level 2.

Page 108: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

107

● When the controller is bypassed, the user level 3 can login the controller without the permission assignment of the user level 2.

● The user level 4 can login the controller only when the user level 2 or level 3 has assigned permissions to the user level 4.

Page 109: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

108

F. Signalling

Detection of ATP/ATS Faults

ATP (Alarm Transmission Path) faults will be detected when network interface of the control

panel disconnected or the transmission path to the transceiver of receiving center located in ARC blocked somewhere in between. An ATS (Alarm Transmission System) fault will be reported when ATP faults are detected on both transmission paths. ATP restore will be detected as soon as network interface connected and the transmission path to the transceiver of receiving center restored. ATS restore will be reported when ATP restore of any transmission path is detected.

The timing performance of detecting ATP faults and restores shows in the table below.

TN Maximum timing of detection

Primary ATP failure/restore LAN/WiFi 10 min

Secondary ATP failure/restore GPRS 60 min

20 min (when primary ATP failed ) 3G/4G LTE

Signalling will be always transmitted from primary ATP when it is operational. Otherwise it will be automatically switched to secondary transmission path that is operational at the moment. Both primary and secondary ATP fault and restore events will be reported to ARC when there is an ATP left to work. They will also be recorded to mandatory log memory with capacity of 1000 records allocated in non-volatile flash memory storage, as well as the ATS fault record. The detail of reports and log records are listed in the table below.

Event code when signalling

Event log description

Primary ATP failure/restore E351/R351 LAN Path Failed/LAN Path Recovery

Secondary ATP failure/restore E352/R352 Mobile Net Path Failed/Mobile Net Path

Recovery

ATS failure/restore N/A ATS Failed

Primary network interface failure/restore E351/R351 LAN Path Failed/LAN Path Recovery

Secondary network interface failure/restore E352/R352 Mobile Net Path Failed/Mobile Net Path

Recovery

ATS Category The ATS category of AXPRO is DP2. While the alarm receiving center is enabled. The control panel will upload alarm report to the receiver center via the main path (LAN or Wi-Fi) or the back-up path (3G/4G). If the control panel is properly connected to the LAN or Wi-Fi, the main path is selected as the transmission path. If the main path connection is failed, the path will be switched to 3G/4G. And if the main path connection is restored, the path will be switched back to LAN or Wi-Fi. The control panel checks the connection status continuously, and generates logs transmission fault for any of the path. While both of the paths are invalid, the control panel determines ATS fault.

Page 110: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

109

G. SIA and CID Code

Table F-1 SIA and CID Code

SIA Code CID Code Description

MA 1100 Medical Alarm

MH 3100 Medical Alarm Restored

BA 1130 Burglary Alarm

BH 3130 Burglary Alarm Restored

FA 1110 Fire Alarm

FH 3110 Fire Alarm Restored

HA 1121 Duress

HA 1122 Silent Panic Alarm

HH 3122 Silent Panic Alarm Restored

NA 1780 Timeout Alarm

BH 3780 Timeout Alarm Restored

PA 1120 Panic Alarm

PH 3120 Panic Alarm Restored

BA 1133 24H Alarm

BH 3133 24H Alarm Restored

BA 1134 Entry/Exit Alarm

BH 3134 Entry/Exit Alarm Restored

TA 1137 Device Tampered

TR 3137 Device Tamper Restored

GA 1151 Gas Leakage Alarm

GH 3151 Gas Leakage Alarm Restored

AT 1301 AC Power Loss

AR 3301 AC Power Restored

YT 1302 Low System Battery

YR 3302 Low System Battery Restored

RN 1305 Control Panel Reset

Page 111: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

110

SIA Code CID Code Description

YM 1311 Battery Fault

YR 3311 Battery Fault Restored

YI 1312 Overcurrent Protection Triggered

YJ 3312 Overcurrent Protection Restored

YP 1319 Overvoltage Protection Triggered

YQ 3319 Overvoltage Protection Restored

XT 1338 Repeater Battery Low

XR 3338 Repeater Battery Voltage Restored

AT 1342 Repeater Mains Power Lost

AR 3342 Repeater Mains Power Restored

YM 1311 Repeater Battery Disconnected

YR 3311 Repeater Battery Reconnected

ES (The serial number of output module starts from 1, of keypad starts from 101, of tag reader starts from 201)

1341 (The serial number of output module starts from 1, of keypad starts from 101, of tag reader starts from 201)

Expander Tampered

EJ (The serial number of output module starts from 1, of keypad starts from 101, of tag reader starts from 201)

3341 (The serial number of output module starts from 1, of keypad starts from 101, of tag reader starts from 201)

Expander Tamper Restored

TA 1334 Wireless Repeater Tampered

TR 3334 Wireless Repeater Tamper Restored

TA 1321 Wireless Siren Tampered

TR 3321 Wireless Siren Tamper Restored

UY 1321 Wireless Siren Disconnected

Page 112: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

111

SIA Code CID Code Description

UJ 3321 Wireless Siren Connected

ES (The serial number of output module starts from 1, of keypad starts from 101, of tag reader starts from 201)

1341 (The serial number of output module starts from 1, of keypad starts from 101, of tag reader starts from 201) Wireless Device Tampered

EJ (The serial number of output module starts from 1, of keypad starts from 101, of tag reader starts from 201)

3341 (The serial number of output module starts from 1, of keypad starts from 101, of tag reader starts from 201)

Wireless Device Tamper Restored

XT 1338 Low Wireless Device Battery

XR 3338 Low Wireless Device Battery Restored

ET (The serial number of output module starts from 1, of keypad starts from 101, of tag reader starts from 201)

1333 (The serial number of output module starts from 1, of keypad starts from 101, of tag reader starts from 201) Wireless Device Disconnected

ER (The serial number of output module starts from 1, of keypad starts from 101, of tag reader starts from 201)

3333 (The serial number of output module starts from 1, of keypad starts from 101, of tag reader starts from 201) Wireless Device Connected

LT 1351 Main Channel ATP Fault

LR 3351 Main Channel ATP Restored

LT 1352 Backup Channel ATP Fault

LR 3352 Backup Channel ATP Restored

TA 1383 Detector Tampered

TR 3383 Detector Tamper Restored

OP 1401 Disarming

CL 3401 Away Arming

OA 1403 Auto Disarming

CA 3403 Auto Arming

BC 1406 Alarm Clearing

1409 CS Keyswitch Zone Disarming

3409 OS Keyswitch Zone Arming

Page 113: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

112

SIA Code CID Code Description

CL 3441 Stay Arming

CT 1452 Late to Disarm

CD 1455 Auto Arming Failed

BB 1570 Zone Bypassed

BU 3570 Zone Bypass Restored

RP 1602 Periodic Report Test

TS 1607 Test Mode Entered

TE 3607 Test Mode Exited

LB 1627 Enter Programming

LX 1628 Exit Programming

BA 1131 Intrusion Alarm

BH 3131 Intrusion Alarm Restored

BA 1131 Cross-Zone Alarm

BH 3131 Cross-Zone Alarm Restored

BA 1134 Region Entrance Detection

FA 1112 Fire Source Alarm

FH 3112 Fire Source Alarm Restored

KS 1158 High Temperature Pre-Alarm

KR 3158 High Temperature Pre-Alarm Restored

1159 ZS Low Temperature Pre-Alarm

ZR 3159 Low Temperature Pre-Alarm Restored

KA 1158 High Temperature Alarm

KH 3158 High Temperature Alarm Restored

ZA 1159 Low Temperature Alarm

ZH 3159 Low Temperature Alarm Restored

EA 1134 Region Exiting Detection

Page 114: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

113

SIA Code CID Code Description

PA (For distinguishing the keypad, the user number of the keyfob starts from 901)

1120 (For distinguishing the keypad, the user number of the keyfob starts from 901)

Keypad/Keyfob Panic Alarm

FA 1110 Keypad/Keyfob Fire Alarm

CI 1454 Arming Failed

MA 1100 Keypad/Keyfob Medical Alarm

DK 1501 Keypad Locked

DO 3501 Keypad Unlocked

/ / Tag Reader Locked

/ / Tag Reader Unlocked

UY 1381 Wireless Detector Disconnected

UJ 3381 Wireless Detector Connected

XT 1384 Wireless Detector Low Battery

XR 3384 Normal Wireless Detector Battery

ET (The serial number of output module starts from 1, of keypad starts from 101, of tag reader starts from 201)

1333 (The serial number of output module starts from 1, of keypad starts from 101, of tag reader starts from 201)

Expander Disconnected

ER (The serial number of output module starts from 1, of keypad starts from 101, of tag reader starts from 201)

3333 (The serial number of output module starts from 1, of keypad starts from 101, of tag reader starts from 201)

Expander Connected

UY 1334 Wireless Repeater Disconnected

UJ 3334 Wireless Repeater Connected

XT 1384 Wireless Siren Low Battery

XR 3384 Normal Wireless Siren Battery

NT 1350 Cellular Data Network Disconnected

NR 3350 Cellular Data Network Connected

Page 115: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

114

SIA Code CID Code Description

NT 1350 Wi-Fi Communication Fault

NR 3350 Wi-Fi Connected

XQ 1344 RF Signal Exception

XH 3344 Normal RF Signal

NT 1350 Network Flow Exceeded

XT 1384 Low Keyfob Battery

XR 3384 Low Keyfob Battery Restored

NT 1350 IP Address Conflicted

NR 3350 Normal IP address

NT 1350 Wired Network Exception

NR 3350 Normal Wired Network

/ / Sending Email Failed

/ / Network Camera Disconnected

/ / Network Camera Connected

/ 3250 Patrol

/ 1306 Detector Deleted

/ 3306 Detector Added

/ 1306 Expander Deleted

/ 3306 Expander Added

/ 1306 Wireless Repeater Deleted

/ 3306 Wireless Repeater Added

/ 1306 Wireless Siren Deleted

/ 3306 Wireless Siren Added

/ 1306 Wireless Device Deleted

/ 3306 Wireless Device Added

Page 116: User Manual - Hikvision · AX PRO User Manual iv Regulatory Information EN 50131-1:2006+A1:2009+A2:2017 EN 50131-3:2009 EN 50131-6:2017 EN 50131-5-3:2017 EN 50131-10: 2014 EN 50136-2:

115

H. Communication Matrix and Operation Command

Please scan the OR code for communication matrix and operation command

AXPRO Communication Matrix AXPRO Operation Command

User Privacy Statement ● The debug or zhimakaimen command is used to control access to the file system to ensure device security. To obtain this permission, you can contact technical support. ● The device has admin, installer, maintenance, operator account. You can use these accounts to access and configure the device.

User Privacy Information Description

Password The password for the device account, used to log in to the device.

Username The username for the device account, used to log in to the device.

Device IP and port The device IP and port are used to support network service communication. For details, refer to Communication Matrix.

Log Used to record information such as device operating status and operation records.

Database information Used to record information.