16
USER MANUAL FURNACE PRO

USER ManUal Furnace PrO · InItIaL tEMPEraturE (tP1) The initial temperature is the initial temperature of the firing process. DryInG tIME (tSEC) The drying time is the waiting period

  • Upload
    others

  • View
    11

  • Download
    0

Embed Size (px)

Citation preview

Page 1: USER ManUal Furnace PrO · InItIaL tEMPEraturE (tP1) The initial temperature is the initial temperature of the firing process. DryInG tIME (tSEC) The drying time is the waiting period

USER ManUal Furnace PrO

Page 2: USER ManUal Furnace PrO · InItIaL tEMPEraturE (tP1) The initial temperature is the initial temperature of the firing process. DryInG tIME (tSEC) The drying time is the waiting period

Dear user, Thank you very much for choosing a KOTA product.KOTA produce equipment with high quality materials seeking to guarantee the confidence and safety of its products.To maintain the perfect functioning of your EVO Oven, some basic care is necessary. Read this manual carefully and follow the instructions for installation and use.

Safety precautions

•UseoriginalKOTAproductsidentifiedbythebrand,whichguaranteethe best performance for your equipment.

•Donotmodifytheequipmentorrequestthirdpartiestodoso,except when specifically KOTA authorize it, as performance and / or security could be compromised. Any alteration of the product without previous authorization will imply the loss of the guarantee.

•Donotuseextensionsoranytypeofconnectorbetweenthepowercord of the appliance and the socket. Procedures such as these could decrease the performance of your equipment and increase your energy consumption.

•Forcleaning,useonlyadampcloth.Donotapplyabrasive,solventor corrosive products on the equipment.

•Donotplaceworkremovedfromtheovendirectlyontheglassatthe base of the work area. Coatings or porcelain freshly removed from the equipment can cause cracks in the glass base. Maximumtemperatureovertheglass:200ºC.

When Turn On the equipment, place the refractory base on the aluminium tray. If do not perform this procedure so the rubber seal ring could be damaged.

Page 3: USER ManUal Furnace PrO · InItIaL tEMPEraturE (tP1) The initial temperature is the initial temperature of the firing process. DryInG tIME (tSEC) The drying time is the waiting period

Index

Features....................................................................................................4

Technicaldata...........................................................................................4

Equipmentoverview................................................................................4

Initial set up............................................................................................. 5

Language selection................................................................................. 6

Selecting & editing firing programs......................................................... 6

Warranty terms and scope.......................................................................15

Page 4: USER ManUal Furnace PrO · InItIaL tEMPEraturE (tP1) The initial temperature is the initial temperature of the firing process. DryInG tIME (tSEC) The drying time is the waiting period

•Multilanguagefunction•Hightemperatureaccuracy•Temperaturesensor(Platen/Rhodium)•Muffleforburningwith(Quartzclear)•100Firingprograms•Linearheatingspeedfrom20°to120°Cperminute

110or220Vequipmentpowersupply(CheckFurnacevoltage)Maximumconsumption:1300WattsFuse:20AMaximumcurrentofthevacuumpumpintake:10AMaximumoperatingtemperature:1150°CHeight:465mmWidth:298mmDepth:420mmNetweight:14,1kgGrossweight:16.2kgFrequency:50-60HzColour:black

Features

Specifications

Equipment Overview

Fuse20AElectrical Connection for the Vacuum Pump

Connection for Vacuum hose

Power Cable

Main Switch ON/OFF

4

Page 5: USER ManUal Furnace PrO · InItIaL tEMPEraturE (tP1) The initial temperature is the initial temperature of the firing process. DryInG tIME (tSEC) The drying time is the waiting period

•1º:beforeturningONcheckifthevoltageiscorrectwiththeequipmentvoltage and then connect PRO to AC power socket.

•2º:placetherefractoryplateonthePROaluminiumtray.

Initial set up

When Turn On the equipment, place the refractory base on the aluminium tray. If do not perform this procedure so the rubber seal ring could be damaged

Aluminium tray

Refractory Plate

•3º:connecttheVacuumPumppowercabletoelectricalconnector locatedonthebackoftheunitasshownintheillustrationonpage3. Check the main voltage. The Vacuum Pump voltage must be the same as that of the oven.

•4º:connecttheVacuumPumppowercabletoelectricalconnector locatedonthebackoftheunitasshownintheillustrationonpage3. Check the main voltage. The Vacuum Pump voltage must be the same as that of the oven.

5

Page 6: USER ManUal Furnace PrO · InItIaL tEMPEraturE (tP1) The initial temperature is the initial temperature of the firing process. DryInG tIME (tSEC) The drying time is the waiting period

Language selection

Available in Portuguese, English and Spanish.To select the language, with the over switch off, press “EDiT” and turn on. Choose the correct option and press “EDiT” to save changes.

ManuaL ELEvatOr MOvEMEnt The left directional key has the function of moving the elevator up, down and stop at the desired position.

StanDby MODETheStand-bymodeservestopreventperipheralheatingoftheovenand to save energy.Whenever the oven remains unused for more than 5 minutes, the mufflewillclose.Toopenthemuffle,pressthedirectionalarrowontheleftside.

Selecting and editing a ceramic program

When selecting the firing program we will have the following indications on thescreen:

On this screen, it is possible to move the lift up, down and stop in any position manually. Just press the left directional arrow to perform the two functions.

Thefiringprogramsrangefromnumber1to99.Thereare33firingprogramsprogrammedfromthefactorythatgofromnumber1to33.These factory programs can be modified according to the instructions detailed below.

inicial temperature

Number of the program selected

6

Page 7: USER ManUal Furnace PrO · InItIaL tEMPEraturE (tP1) The initial temperature is the initial temperature of the firing process. DryInG tIME (tSEC) The drying time is the waiting period

To edit a ceramic program, select a program number, and then press “EDiT”.

Whenpressthe“EDiT”keyscreenswillappearinthefollowingorder:

InItIaL tEMPEraturE (tP1)

The initial temperature is the initial temperature of the firing process.

DryInG tIME (tSEC)

The drying time is the waiting period for the start of the closing stage of themuffle.

rISE tIME (tSub)

Theclosingtimeofthemufflecanbeadjustedtoclosedirectlyorforaspecifictimebetween00:40secondsand30:00minutes.Toactivatethedirectclosingadjusttheparametersin00:00.

7

Page 8: USER ManUal Furnace PrO · InItIaL tEMPEraturE (tP1) The initial temperature is the initial temperature of the firing process. DryInG tIME (tSEC) The drying time is the waiting period

PrE-FIrInG tIME (tPrE)

ThePRE-FiRiNGtimestartswhentherisetimereached90%ofthecourse.The elevator remains in the position by the programmed time and then the mufflewillclose.

DOWnInG tIME (tDES)

Thedowningtimeisactivatedafterthelastfiringprocessbeexecutedandcanbeadjustedfordirectopeningorforadeterminedtimebetween00:40secondsand30:00minutes.Toactivatethedirectopening,settheparametersto00:00.

baSE tEMPEraturE (tP2)

itisthenexttemperaturelevelaftertheinitialtemperature.

8

Page 9: USER ManUal Furnace PrO · InItIaL tEMPEraturE (tP1) The initial temperature is the initial temperature of the firing process. DryInG tIME (tSEC) The drying time is the waiting period

HEatInG ratE (tr2)

It is the heating rate between the initial temperature and the base temperature2.Theparameterscanbeadjustedfrom20°to120°Cperminute.

vaCuuM raMP 2 (vr2)

Determinesiftherewillbeavacuumbetweentheinitialtemperatureuptothebasetemperature2.UsetheONorOFFfunctiontoconfiguretheparameter.

baSE tIME (tPat2)

Determinesthetemperaturedwelltimeprogrammedinbase2.

9

Page 10: USER ManUal Furnace PrO · InItIaL tEMPEraturE (tP1) The initial temperature is the initial temperature of the firing process. DryInG tIME (tSEC) The drying time is the waiting period

vaCuuM tIME 2 (tvaC2)

Determinethevacuumtimewithinbasetime2.ifthevacuumramp2isdisabled,itwillnotbepossibletosetthevacuumtime2.Thevacuumtimemustalwaysbeequaltoorlessthanthebasetime.

baSE tEMPEraturE 3 (tP3)

Enablesordisablesthe3rdbase.ifthisparameterisdisabled,thenextparametertobeexecutedisthedowning time and then the program completion.

tEMPEraturE baSE 3 (tP3)

itisthenexttemperaturelevelafterthebasetemperature2.

10

Page 11: USER ManUal Furnace PrO · InItIaL tEMPEraturE (tP1) The initial temperature is the initial temperature of the firing process. DryInG tIME (tSEC) The drying time is the waiting period

HEatInG ratE (tr3)

itistheheatingratebetweenthebasetemperature2andthebasetemperature3.

vaCuuM raMP 3 (vr3)

Determineiftherewillbeavacuumbetweenthebasetemperature2tothebasetemperature3.Usethe“enable”or“disable”functiontoconfiguretheparameter.

baSE tIME 3 (tPat3)

Determinethedwelltimeofthebasetemperature3.

11

Page 12: USER ManUal Furnace PrO · InItIaL tEMPEraturE (tP1) The initial temperature is the initial temperature of the firing process. DryInG tIME (tSEC) The drying time is the waiting period

vaCuuM tIME 3 (tvaC3)

Determinethevacuumtimewithinbasetime3.iftheVacuuminramp3isdisableditwillnotbepossibletoconfigurethevacuumtime3.Thevacuumtimemustalwaysbeequaltoorlessthanthebase time.

baSE tEMPEraturE 4 (tP4)

Enableordisablethe4°base.ifthatparameterwasdisabled,thenextparametertobeexecutedisthedownload time and then the program completion.

baSE tEMPEraturE 4 (tP4)

itisthenexttemperaturelevelafterthebasetemperature3.

12

Page 13: USER ManUal Furnace PrO · InItIaL tEMPEraturE (tP1) The initial temperature is the initial temperature of the firing process. DryInG tIME (tSEC) The drying time is the waiting period

HEatInG ratE (tr4)

itisthedeterminedtimebetweenthebasetemperature3andthebasetemperature4.

vaCuuM raMP 4 (vr4)

Determineiftherewillbeavacuumbetweenthebasetemperature3uptothebasetemperature4.UsetheONfunctiontoenableorOFFtodisableforconfigurationoftheparameter.

baSE tIME 4 (tPat4)

Determinethedwelltimeofthebasetemperature4.

13

Page 14: USER ManUal Furnace PrO · InItIaL tEMPEraturE (tP1) The initial temperature is the initial temperature of the firing process. DryInG tIME (tSEC) The drying time is the waiting period

vaCuuM tIME 4 (tvaC4)

Determinethevacuumtimewithinbasetime4.ifVacuumRegulator4isdisabled,itwillnotbepossibletosettheemptytime4.The vacuum time must always be equal to or less than the base time.

aLtEr naME OF tHE PrOGraM

Toalterthenameoftheprogram,pressthe“EDiT”keyfor2(two)seconds until the name of the program appears on the screen.The cursor will blink in the first field to be altered.To alter the name of the program, use the up and down arrows.To navigate between the edit fields, press the right or left arrow keys.Tosave,pressthe“EDiT”key.

14

Page 15: USER ManUal Furnace PrO · InItIaL tEMPEraturE (tP1) The initial temperature is the initial temperature of the firing process. DryInG tIME (tSEC) The drying time is the waiting period

Warranty terms and scope

KOTA Equipamentos guarantees the product and its accessories for defects in materials and workmanship; always they have been used in accordancewiththeconditionsofusespecifiedintheUser’sManual.The warranty period is one year from the date of the purchase invoice, being3(three)monthsoflegalguaranteeand9(nine)monthsofcontractual guarantee.Thereplacedpartsoraccessorieswillbeguaranteedforaperiodof90(ninety)daysfromthedateofreturnoftheappliancetothecustomerorforthe remaining time of the original warranty, whichever is the last.

Warranty: ItEMS ExCLuDED

Thiswarrantydoesnotcover:•Damageresultingfromtheuseoftheproductinamannerotherthan thatspecifiedintheuser’smanual.•Defectscausedbyinstallations,alterations,testsoranytypeof modifications by people or technical services not authorized by KOTA Equipamentos.•Productswiththeserialnumberremovedorillegible.•Damagescausedbyspillageofaggressivesubstancesontheproduct.•Electricaldischargesorvariationsofelectricalcurrentthatmaydamage the equipment.

In case of be necessary to contact KOTA Equipamentos, have the purchase invoice of the equipment and the respective serial number.

15

Page 16: USER ManUal Furnace PrO · InItIaL tEMPEraturE (tP1) The initial temperature is the initial temperature of the firing process. DryInG tIME (tSEC) The drying time is the waiting period

KOta Equipamentoskotaimp.com.brRuaÍrisMemberg,140VilaJovina-Cotia,SPiCEP06705150iBrazil551146159200

tECHnICaL [email protected]|5511994883529

[email protected] 551146159200|5511961962763