USER MANUAL
EAR AND FOREHEADTHERMOMETER
PRODUCT STRUCTURE
(1) Probe cover
(2) Probe
(3) LCD display
(4) Power/ Measure
(5) °F/°C switch
(6) Mode(Adult/Child/Object)
(7) Battery cover
(8) Memory/Mute
5
1
6
7
4
3
2
8
Structure
Probe cover1
Cover on | Cover off
Ear ModeForehead/Object mode
Automatically switched between forehead & ear mode.
USE INSTRUCTIONS
Measuring foreheadtemperature
With the probe cover attached, point the thermometer at the center of the forehead.
Move the thermometer towards the forehead until the probe cover 1-3 cm away from the skin.
Press and release the Measure button. The temperature will be displayed on the screen instantly.
Make sure that the forehead is free of hair and perspiration.
1
2
3
Measuring temperature via eardrum
Gently remove the probe cover to reveal the ear probe.
Insert the ear probe into the ear canal.
Press and release the Measure button. The temperature will be displayed on the screen instantly.
Make sure that the ear canal is straight so that the sensor is in line with the eardrum.
1
2
3
Make sure that the ear canal is straight so that the sensor is in line with the eardrum.
FEATURES
Good safety
Passive infrared receiving technology
Easy operation
Ergonomic design
One button measurement
Quick measurement
1-second measurement
High accuracy
Advanced infrared temperature sensor, with high sensitivity
High accuracy with automatic temperature calibration
Diverse functions
20 readings recall
Fever alert
Switching between ºC and ºF
Automatic power-off, power saving
Extensive application scope
Forehead temperature measurement applicable to all age groups
Ear temperature measurement applicable to children older
than three months, adults, and the elderly
Child mode
This mode is recommended for people under 12 years of age
1
2
3
4
5
6
7
DISPLAY DESCRIPTION1 Object temperature mode
2 Forehead temperature mode
3 Child mode
4 Ear temperature mode
5 Mute/un-mute
6 Temperature unit (ºF/ºC)
7 Low battery
8 Memory recall
9 Temperature value
Screen Display Operating Instructions
Measuring Ear temperature (Adult / Child)
Ear temperaturefor adult
Take off the probe cover, press andrelease the Power button for 1second to power on thethermometer. The symbol “ ” isdisplayed on the screen.
Switch to the adult or childmeasurement mode by pressing theMode button according to yourmeasurement needs.
Insert the temperature probe into aproper position in the ear canal.Press the Measure button to start ameasurement.
See the table in the“Sounds andbacklight colorinstructions”section.
Sound andBackground Light
Ear temperaturefor child
SCREEN DISPLAY OPERATING INSTRUCTIONS
Measuring Forehead temperature (Adult / Child)
Forehead temperature
for adult
SOUND ANDBACKLIGHT
COLOR
Forehead temperature
for child
Put the cover on the probe, pressand release the Power button for 1second to power on thethermometer The “Head” symbol
is displayed on the screen.
Switch to the adult or childmeasurement mode by pressing theMode button according to yourmeasurement needs.
Point the thermometer to the centerof the forehead.about”1-3cm ”away from the skin surface. Pressand release the Measure button.The temperature will be displayedon the screen.
See the table in“Sounds andbacklight colorinstructions”section.
DISPLAY DESCRIPTION
Put the cover on the probe, switchto the object measurement mode bypressing the Mode button.Thethermometer enters the Objectmode. The “House” symbol isdisplayed on the screen.
Point the thermometer to the centerof the object. Press and release theMeasure button. The temperaturewill be displayed on the screen.
See the table in the“Sounds andbacklight colorinstructions”section.
In Ear mode, a temperature readingof more than 42.0ºC (107.6ºF)
In Forehead mode, a temperaturereading of more than 42.2ºC(108.0ºF)
In Object mode, a temperaturereading of more than 100ºC(212.0ºF)
A long beeps,thebacklight is red.
For referenceonly
In Ear mode, a temperature readingof less than 35.0ºC (95.0ºF)In Forehead mode, a temperaturereading of less than 35.0ºC (95.0ºF)In Object mode, a temperaturereading of less than 0ºC (32.0ºF)
A long beeps, thebacklight is red.
SCREEN DISPLAY OPERATING INSTRUCTIONS
SOUND ANDBACKLIGHT
COLOR
Out of the Measuring Range Display
Recall 20 memories
For referenceonly
In a power-on state, press theMemory button enter the memorymode.
When the Memory button isreleased, 01 will be shown,followed by the recorded reading.
Press the Memory button again forthe next recorded data. 02 will beshown, followed by the recordedreading.
A maximum of 20 temperaturereadings can be recalled.When the maximum number ofrecords is exceeded, the earliestmemory data will be overwritten.
Note:01 means the latest data.
Silent,thebacklight is
green.
SCREEN DISPLAY OPERATING INSTRUCTIONS
SOUND ANDBACKLIGHT
COLOR
No memory data / Clear memory data
The display is as shown , whenthere is no more data checked whilerecalling memories. Remove 2 drybatteries and after 10 secondsre-install the power to clear allmemory data.
When the power isturned back on,there are a longbeep and a greenbacklight, whichthen turns into red.
In the power-on state, press andhold the sound switch button forabout 2 seconds to switch the soundon or off. When the sound is turnedon, it will beep once and the mutesymbol will be displayed when thesound is off.
The symbol shows up in Mutemode and disappears in Un-mutemode.
When the sound isturned on, itsounds a longbeep and thebacklight isgreen.
SCREEN DISPLAY OPERATING INSTRUCTIONS
SOUND ANDBACKLIGHT
COLOR
Switching between mute and un-mute
Switching between object temperature and body temperature
When putting on the probe cover,press the Mode button to switchbetween object and foreheadmodes. Ear mode (adult/child) willbe activated by removing the probecover.
Silent, thebacklight is green.
In a power-on state,you can changeunits, by switching the ºF/ºCbutton.
Silent
SCREEN DISPLAY OPERATING INSTRUCTIONS
SOUND ANDBACKLIGHT
COLOR
Switching between ºF/ºC
The ambient temperature is higherthan 40.0ºC (104.0ºF) or lower than10.0ºC (50.0ºF).
A long beeps,thebacklight is red.
An error occurs when data is beingread from or written to the memory,or the temperature correction is notcomplete.
A long beeps,thebacklight is red.
When the battery voltage is lowerthan 2.4V ± 0.1V, the low batterysymbol will appear on the display.Please replace the batteries.
Silent
SCREEN DISPLAY OPERATING INSTRUCTIONS
SOUND ANDBACKLIGHT
COLOR
Error Information & Low Battery
24
The temperaturereading is higherthan the typicalbody temperaturerange.
The temperature probeis damaged.
Contact themanufacturer.
Product Name Infrared ThermometerProduct Model JPD-FR412Power SupplyMode
Internal power supply
Operating Voltage DC 3VBattery Model AAA x 2Operating Mode Continuous operatingDisplay Segment LCDMeasure time About 1 secondLatency Time About 3 seconds
Measuring RangeForehead mode:35.0°C–42.2°C (95.0°F–108.0°F)Ear mode:35.0°C–42.0°C (95.0°F–107.6°F)Object mode:0.0°C–100.0°C (32.0°F–212.0°F)
Accuracy(Laboratory)
Forehead mode: ±0.2°C (±0.4°F)Ear mode: ±0.2°C (±0.4°F)Object mode: ±1.0� /±2.0�
Resolution 0.1°C (0.1°F)Memory 20 temperature readings
Low-battery AlertThe low-battery symbol is displayed if the powervoltage is lower than 2.4 V±0.1V
AutomaticPower-off
The thermometer automatically powers off if it is notused in 10±1 seconds.
SPECIFICATIONS
24
The temperaturereading is higherthan the typicalbody temperaturerange.
The temperature probeis damaged.
Contact themanufacturer.
Product Name Infrared ThermometerProduct Model JPD-FR412Power SupplyMode
Internal power supply
Operating Voltage DC 3VBattery Model AAA x 2Operating Mode Continuous operatingDisplay Segment LCDMeasure time About 1 secondLatency Time About 3 seconds
Measuring RangeForehead mode:35.0°C–42.2°C (95.0°F–108.0°F)Ear mode:35.0°C–42.0°C (95.0°F–107.6°F)Object mode:0.0°C–100.0°C (32.0°F–212.0°F)
Accuracy(Laboratory)
Forehead mode: ±0.2°C (±0.4°F)Ear mode: ±0.2°C (±0.4°F)Object mode: ±1.0 /±2.0°C °F
Resolution 0.1°C (0.1°F)Memory 20 temperature readings
Low-battery AlertThe low-battery symbol is displayed if the powervoltage is lower than 2.4 V±0.1V
AutomaticPower-off
The thermometer automatically powers off if it is notused in 10±1 seconds.
SPECIFICATIONS
Outer dimensions(mm)
155.9*40.2*49.2mm
Weight (g) Thermometer (with batteries): 90g
OperatingEnvironment
Temperature: 10°C~ 40°C (50°F–104°F)Humidity: 15%–95% RH, non-condensingAtmospheric pressure: 86–106 kPa
The infrared thermometer has been tested and conforms to the standard
ASTM E1965-98. ASTM laboratory accuracy requirements in the display
range of 96.8°F to102.2°F (36°C-39°C) for ear canal IR thermometers is
±0.4°F (±0.2°C). Note that for mercury-in-glass and electronic
thermometers, the requirement per ASTM Standards E667-86 and
E1112-86 is ±0.2°F (±0.1°C).
Security Class
Type of protection against electric shock: internally powered equipment.
Degree of protection against electric shock: Type BF applied part.
■ Degree of protection against ingress of water:IP22
■ Safety degree of using in flammable anesthetic gas blending with air,
oxygen or nitrous oxide: Non-AP/APG
■ No application parts of the thermometer prevents defibrillation charge
effect.
■ No application parts of the thermometer output signal.
■ The thermometer is impermanent installed device.
Storage and Transportation
NOTICE
Please use the thermometer indoor or in an environment where there is no strong air draft.
Make sure that both user and thermometer have stayed in steady-state room condition for at least 30 minutes.
Please wait at least 10 minutes before using the thermome-ter, If the thermometer is transferred from an environment.
Operating environment
Keep sensor clean
Check and clean the lens regularly. If it’s not clear, please clean it with a cotton swab with alcohol, wait 5-10 mins, you can use thermometer after alcohol evaporated completely.
Forehead mode: make sure there isn’t any sweat, water or condensation on it.
Ear mode: please remove earwax, keep the ear canal clean.
Keep forehead/ear clean
Don’t move during measurement.
Don’t hold the thermometer for long time as it’s highly sensitive to heat.
Do not repeat use with no pause. If taking multiple readings, it is advised to wait at least 10 seconds between readings.
NOTICE