174
WinLink™ 1000 Broadband Wireless Transmission System User Manual and Installation Guide Version 1.750

User Manual

Embed Size (px)

Citation preview

WinLink 1000

Broadband Wireless Transmission SystemUser Manual and Installation GuideVersion 1.750

WinLink 1000User Manual and Installation GuideNoticeThis manual contains information that is proprietary to RADWIN Ltd. ("RADWIN"). No part of this publication may be reproduced in any form whatsoever without prior written approval by RADWIN Ltd. Right, title and interest, all information, copyrights, patents, know-how, trade secrets and other intellectual property or other proprietary rights relating to this manual and to the WinLink 1000 under international copyright law and shall be and remain solely with RADWIN. and any software components contained therein are proprietary products of RADWIN protected WinLink 1000 is a registered trademark of RADWIN. No right, license, or interest to such asserted by you with respect to such trademark.

trademark is granted hereunder, and you agree that no such right, license, or interest shall be You shall not copy, reverse compile or reverse assemble all or any portion of the Manual or the distribute, license, or sell any product that supports substantially similar functionality as the paragraph shall survive the termination of this Agreement. WinLink 1000. You are prohibited from, and shall not, directly or indirectly, develop, market,

WinLink 1000 based on or derived in any way from the WinLink 1000. Your undertaking in this This Agreement is effective upon your opening of the WinLink 1000 package and shall continue until terminated. RADWIN may terminate this Agreement upon the breach by you of any term all copies and portions thereof. hereof. Upon such termination by RADWIN, you agree to return to RADWIN the WinLink 1000 and

For further information contact RADWIN at the address below or contact your local distributor.RADWIN Corporate Headquarters 27 Habarzel Street, Tel Aviv, 69710, Israel Tel: +972.3.766.2900 Fax: +972.3.766.2902

WinLink User and Installation Guide

Version 1.750

1-2

RADWIN Worldwide OfficesCorporate Headquarters27 Habarzel Street Tel Aviv, 69710 Israel Tel: +972.3.766.2917

India HeadquartersMohan Co-operative Industrial Estate E-13, B-1 Extn New Delhi, 110044 India Tel: +91.11.40539180

Support Headquarters 27 Habarzel Street Tel Aviv, 69710 Israel Tel: +972.3.766.2900 Mobile: +972.54.766.0044

APAC Headquarters1 Jalan Kuala #13-01 The Morningside, 239639 Singapore Tel: +65.9878.3004 Indonesia Sales Office Jl. Jenderal Sudirman Kav. 86 Jakarta, 10220 Indonesia Tel: +62.8138.570.0657 Philippines Sales Office 37A. A luna St. West Rembo Makati City, 1200 Philippines Tel: +63.2882.6886 Mobile: +63.9178923427 China Sales Office Asian Games Village Huiyuan Gongyu J1312 Beijing 100101 China Tel: +86-010-84980629

North America Headquarters900 Corporate Drive Mahwah, NJ 07430 USA Tel (1): 1.800.444.7234 / 341 Tel (2): +1.201.529.1100 / 341

Latin America HeadquartersRua Grao Mogol 828 Belo Horizonte, MG 30310-010 Brazil Tel (1): +55.31.919.76.402 Tel (2): +972.54.7586808

For sales support contact: [email protected] For technical support contact: [email protected] For technical support in India only, contact: [email protected]

WinLink User and Installation Guide

Version 1.750

1-3

FCC User InformationThis equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Changes or modifications to this equipment not expressly approved by the party responsible for compliance (WinLink 1000) could void the users authority to operate the equipment. It is the responsibility of the installer to ensure that when using the outdoor antenna kits in the United States (or where FCC rules apply), only those antennas certified with the product are used. The use of any antenna other than those certified with the product is expressly forbidden in accordance to FCC rules CFR47 part 15.204. Outdoor units and antennas should be installed ONLY by experienced installation professionals who are familiar with local building and safety codes and, wherever applicable, are licensed by the appropriate government regulatory authorities. Failure to do so may void the WinLink 1000 warranty and may expose the end user or the service provider to legal and financial liabilities. Radwin and its resellers or distributors are not liable for injury, damage or violation of regulations associated with the installation of outdoor units or antennas. FCC Notation for Indoor Units IDU-E and IDU-C Concerning all models and configurations This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may cause undesired operation.

WinLink User and Installation Guide

Version 1.750

1-4

Table of ContentsFCC USER INFORMATION................................................................................................................ 1-4 CHAPTER 1 INTRODUCTION............................................................................................................ 1-12 KEY APPLICATIONS ............................................................................................................................... 1-12 Cellular Backhaul ............................................................................................................................ 1-12 Broadband Access............................................................................................................................ 1-13 Private Networks.............................................................................................................................. 1-14 Video Surveillance ........................................................................................................................... 1-15 WINLINK 1000 KEY FEATURES ......................................................................................................... 1-15 TDM + Ethernet in one Solution...................................................................................................... 1-15 Simple Installation ........................................................................................................................... 1-15 Advanced Air Interface .................................................................................................................... 1-15 Automatic Adaptive Rate.................................................................................................................. 1-16 Unique Multi Point-to-Point Deployment ........................................................................................ 1-16 Enhanced Air Interface Security ...................................................................................................... 1-16 Advanced Management and Performance Monitoring .................................................................... 1-16 HOW TO USE THIS MANUAL .................................................................................................................. 1-16 CHAPTER 2 OVERVIEW ..................................................................................................................... 2-18 WINLINK 1000 SYSTEM COMPONENTS .............................................................................................. 2-18 The Indoor Unit (IDU)..................................................................................................................... 2-19IDU-E........................................................................................................................................................... 2-19 IDU-C .......................................................................................................................................................... 2-19 IDU-R .......................................................................................................................................................... 2-19 Power Over Ethernet Units .......................................................................................................................... 2-20

The Outdoor Unit (ODU)................................................................................................................. 2-21 WinLink 1000 Manager................................................................................................................ 2-23 (All Indoor Unit) AIND .................................................................................................................... 2-24 TECHNICAL SPECIFICATIONS ................................................................................................................. 2-25 Air Interface ..................................................................................................................................... 2-25 Frequency Bands and Channel Bandwidth...................................................................................... 2-25 Rates and Services Supported .......................................................................................................... 2-25 Regulations ...................................................................................................................................... 2-26 Ethernet Services ............................................................................................................................. 2-26 TDM (E1/T1) Services ..................................................................................................................... 2-27 Technical Specification Summary .................................................................................................... 2-28 CHAPTER 3 INSTALLATION AND SETUP...................................................................................... 3-31 SITE REQUIREMENTS AND PREREQUISITES ............................................................................................ 3-31 PACKAGE CONTENTS ............................................................................................................................. 3-31 INSTALLATION SEQUENCE ..................................................................................................................... 3-33 INSTALLING THE WINLINK MANAGEMENT SOFTWARE ......................................................................... 3-35 Minimum Requirements ................................................................................................................... 3-35 Installing the Software ..................................................................................................................... 3-36 MOUNTING THE ODU............................................................................................................................ 3-36 CONNECTING THE ODU TO THE IDU..................................................................................................... 3-37 CONNECTING THE GROUND TO THE IDU ............................................................................................... 3-39 CONNECTING POWER TO AN IDU .......................................................................................................... 3-39 CONNECTING POWER TO AN O-POE ...................................................................................................... 3-40 ALIGNING ANTENNAS WITH THE BEEPER .............................................................................................. 3-40 INSTALLING THE LINK ........................................................................................................................... 3-42 Changing the Link Password ........................................................................................................... 3-44 CONNECTING THE USER EQUIPMENT ..................................................................................................... 3-45 SELECTING CHANNELS .......................................................................................................................... 3-47

WinLink 1000 with Automatic Channel Select ............................................................................. 3-47 WinLink 5.4 GHz ETSI Version ....................................................................................................... 3-48 WinLink BRS Version................................................................................................................... 3-49 SELECTING THE SERVICE PARAMETERS ................................................................................................. 3-51 SETTING THE CLOCK CONFIGURATION .................................................................................................. 3-52 SETTING THE T1 LINE CODE .................................................................................................................. 3-54 SETTING THE TDM BACKUP (FOR IDU-R ONLY).................................................................................. 3-55 CHAPTER 4 GETTING STARTED ..................................................................................................... 4-58 TURNING ON WINLINK ......................................................................................................................... 4-58 CONTROLS AND INDICATORS ................................................................................................................. 4-58 IDU Front Panel Indicators............................................................................................................. 4-58ODU/LAN Indicators................................................................................................................................... 4-59 IDU Back Panel Indicators........................................................................................................................... 4-60

ODU Indicators ............................................................................................................................... 4-60 Default Settings................................................................................................................................ 4-60 STARTING THE WINLINK MANAGER SOFTWARE ................................................................................... 4-61 Over the Air Connection indication ................................................................................................. 4-64 MANAGING WINLINK ............................................................................................................................ 4-65 Turning Off WinLink ........................................................................................................................ 4-68 CHAPTER 5 CONFIGURING THE LINK.......................................................................................... 5-69 LINK CONFIGURATION WIZARD ............................................................................................................ 5-70 Configuring System Parameters ...................................................................................................... 5-70 Selecting Channels: Automatic Channel Select ............................................................................... 5-71The 5.4 GHz ETSI Version .......................................................................................................................... 5-73 BRS Version: Configuring BRS Channel Settings....................................................................................... 5-75

Configuring Service Parameters...................................................................................................... 5-76 Configuring TDM Operation ........................................................................................................... 5-78Setting the Clock Configuration................................................................................................................... 5-78

Setting the T1 Line Code.................................................................................................................. 5-80Setting the TDM Backup (IDU-R only)....................................................................................................... 5-81

CONFIGURING THE SITE ......................................................................................................................... 5-82 Editing the Configuration Parameters by Site ................................................................................. 5-82Functions on the left of the dialog box:........................................................................................................ 5-82 Functions at the top of the dialog box: ......................................................................................................... 5-83

Changing the Transmit Power ......................................................................................................... 5-84 Defining the Management Addresses............................................................................................... 5-85 Configuring VLAN Settings.............................................................................................................. 5-86 Setting the Date and Time................................................................................................................ 5-88 Configuring the Bridge .................................................................................................................... 5-89ODU Bridge Mode....................................................................................................................................... 5-90 IDU Aging time ........................................................................................................................................... 5-90

Configuring Ethernet Mode ............................................................................................................. 5-91 Setting the Maximum Information Rate ........................................................................................... 5-92 Configuring the Jitter Buffer............................................................................................................ 5-92 Changing Community Values........................................................................................................... 5-94 Editing Community Strings .............................................................................................................. 5-94 Forgotten Community string............................................................................................................ 5-95 Muting the alignment tone ............................................................................................................... 5-96 Setting External Alarm Inputs.......................................................................................................... 5-97 MANAGING CONFIGURATION FILES ....................................................................................................... 5-98 Saving Configuration in a File......................................................................................................... 5-98 Restoring a Configuration File ........................................................................................................ 5-98 Resetting........................................................................................................................................... 5-98 Displaying the Inventory.................................................................................................................. 5-99 CONFIGURATION VIA TELNET .............................................................................................................. 5-100

WinLink User and Installation Guide

Version 1.750

1-6

CHAPTER 6 MONITORING AND TESTING THE LINK ............................................................. 6-103 RETRIEVING LINK INFORMATION (GET LINK INFORMATION) .............................................................. 6-103 LINK COMPATIBILITY .......................................................................................................................... 6-104 TESTING THE CONNECTION ................................................................................................................. 6-105 Local External Loopback ............................................................................................................... 6-106 Remote Internal Loopback ............................................................................................................. 6-107 Remote External Loopback ............................................................................................................ 6-108 Local Internal Loopback................................................................................................................ 6-108 REINSTALLING/REALIGNING THE LINK ................................................................................................ 6-109 THE LINK BUDGET CALCULATOR ........................................................................................................ 6-109 PERFORMANCE MONITORING .............................................................................................................. 6-110 The Monitor Log ............................................................................................................................ 6-111Saving the Monitor Log ............................................................................................................................. 6-111 Viewing Performance Reports ................................................................................................................... 6-112 Performance Monitoring Report Toolbar ................................................................................................... 6-115 Setting Air Interface Thresholds ................................................................................................................ 6-115

The Events Log............................................................................................................................... 6-116Setting the Events Preferences ................................................................................................................... 6-118 Saving the Events Log ............................................................................................................................... 6-119 Error Detection and Alarms ....................................................................................................................... 6-120 Remote Power Fail Indication.................................................................................................................... 6-121

CHAPTER 7 SECURITY .........................................................................................................................122 ENTERING AND CHANGING PASSWORDS..................................................................................................122 Changing the Management Password ...............................................................................................122 Changing the Link Password .............................................................................................................123 Forgotten Link Password...................................................................................................................123 CHAPTER 8 DIAGNOSTICS AND TROUBLESHOOTING ..............................................................125 REPLACING AN ODU ...............................................................................................................................126 RESTORE FACTORY SETUP ......................................................................................................................126 FREQUENTLY ASKED QUESTIONS ............................................................................................................126 ONLINE HELP ..........................................................................................................................................130 TECHNICAL SUPPORT ..............................................................................................................................130 CHAPTER 9 APPENDIX A: WIRING SPECIFICATIONS ................................................................131 USER PORT CONNECTORS........................................................................................................................131 Trunk Port..........................................................................................................................................131 LAN Port ............................................................................................................................................132 LAN Port for PoE-8 ...........................................................................................................................132 IDU-C CONNECTORS...............................................................................................................................133 IDU-C DC Power Terminal...............................................................................................................133 IDU-C Alarm Connector....................................................................................................................134 PoE Alarm Connector........................................................................................................................135 IDU-R and IDU-AL Alarm Connectors .............................................................................................135 O-PoE to PC LAN Cable ...................................................................................................................137 CHAPTER 10 APPENDIX B: MAST AND WALL INSTALLATION ......................................... 10-138 ODU OR O-POE MOUNTING KIT CONTENTS ..................................................................................... 10-138 Mounting WinLink 1000 on a Mast.......................................................................................... 10-139 Mounting WinLink on a Wall ....................................................................................................... 10-140 MOUNTING AN EXTERNAL ANTENNA ................................................................................................ 10-141 External Antenna Mounting Kit Contents .................................................................................... 10-141 CHAPTER 11 APPENDIX C: AIND ALIGNMENT....................................................................... 11-142 EXPECTED SIGNAL LEVEL FOR AIND RADIOS ................................................................................... 11-142

WinLink User and Installation Guide

Version 1.750

1-7

PERFORMING WINLINK AIND ALIGNMENT ...................................................................................... 11-143 Equipment Setup .......................................................................................................................... 11-143 Aligning the antennas................................................................................................................... 11-143Configuring the Link................................................................................................................................ 11-144 Evaluating the Link .................................................................................................................................. 11-144 Troubleshooting ....................................................................................................................................... 11-144

CHAPTER 12 APPENDIX D: ANTENNA ....................................................................................... 12-146 CHAPTER 13 APPENDIX E: HUB SITE SYNCHRONIZATION................................................ 13-148 COLLOCATION PLANNING.................................................................................................................. 13-149 HARDWARE INSTALLATION ............................................................................................................... 13-150 ODU/HSS Connection Pinout...................................................................................................... 13-151 ARCHITECTURE ................................................................................................................................. 13-151 RADIO FRAME PATTERN TABLE ........................................................................................................ 13-152 HSS LINK CONFIGURATION............................................................................................................... 13-152 SITE CONFIGURATION........................................................................................................................ 13-155 CHAPTER 14 APPENDIX F: BRS INSTALLATION PROCEDURE .......................................... 14-158 BRS LINK ACTIVATION ..................................................................................................................... 14-158 BRS LINK CONFIGURATION .............................................................................................................. 14-160 CHAPTER 15 APPENDIX G: RF EXPOSURE............................................................................... 15-162 CHAPTER 16 APPENDIX H: LINK BUDGET CALCULATOR.................................................. 16-163 OVERVIEW......................................................................................................................................... 16-163 DESCRIPTION OF PARAMETERS .......................................................................................................... 16-164 Example 1 .................................................................................................................................... 16-164 Example 2 .................................................................................................................................... 16-164 USING THE LINK BUDGET CALCULATOR ........................................................................................... 16-166 CHAPTER 17 APPENDIX I - PRODUCT SPECIFICATION TABLE......................................... 17-168 CHAPTER 18 APPENDIX J LIGHTNING & GROUNDING GUIDELINES .......................... 18-170 GROUNDING FOR INDOOR/OUTDOOR UNITS ...................................................................................... 18-170 ODU (Out Door Unit) Grounding ............................................................................................... 18-170 IDU (Indoor Unit) Grounding ..................................................................................................... 18-170 EXTERNAL LIGHTNING SURGE SUPPRESSORS .................................................................................... 18-170 INTERNAL ESD PROTECTION CIRCUITS ............................................................................................. 18-171 CHAPTER 19 INDEX......................................................................................................................... 19-172

WinLink User and Installation Guide

Version 1.750

1-8

List of FiguresFIGURE 1-1: TYPICAL CELLULAR BACKHAUL APPLICATION ...................................................................... 1-13 FIGURE 1-2: TYPICAL BROADBAND ACCESS APPLICATION ........................................................................ 1-13 FIGURE 1-3: TYPICAL WIFI BACKHAUL APPLICATION ............................................................................... 1-14 FIGURE 1-4: MULTI POINT-TO-POINT ENTERPRISE CONNECTIVITY ........................................................... 1-14 FIGURE 1-5: MULTI POINT-TO-POINT VIDEO SURVEILLANCE DEPLOYMENT............................................. 1-15 FIGURE 2-1: EXAMPLE OF LINK ARCHITECTURE ........................................................................................ 2-18 FIGURE 2-2: IDU-E FRONT PANEL ............................................................................................................. 2-19 FIGURE 2-3: IDU-E BACK PANEL............................................................................................................... 2-19 FIGURE 2-4: IDU-C FRONT PANEL ............................................................................................................. 2-19 FIGURE 2-5: IDU-R FRONT PANEL ............................................................................................................. 2-19 FIGURE 2-6: IDU-R BACK PANEL .............................................................................................................. 2-19 FIGURE 2-7: BACKUP LINK FOR E1/T1 CONNECTIONS ................................................................................ 2-20 FIGURE 2-8: POE ........................................................................................................................................ 2-20 FIGURE 2-9: O-POE UNIT ........................................................................................................................... 2-21 FIGURE 2-10: ODU WITH INTEGRATED ANTENNA ...................................................................................... 2-21 FIGURE 2-11: TYPICALLY USED EXTERNAL ANTENNAS ............................................................................. 2-22 FIGURE 2-12: WINLINK 1000 MANAGER SCREEN ................................................................................... 2-23 FIGURE 2-13: AIND - "ALL INDOOR" UNIT CONNECTED TO ANTENNA ....................................................... 2-24 FIGURE 3-1: TYPICAL INSTALLATION DIAGRAM (WITH EXTERNAL ANTENNA) ........................................... 3-34 FIGURE 3-2: TYPICAL IDU-E REAR PANEL ................................................................................................ 3-38 FIGURE 3-3: IDU-R REAR PANEL ............................................................................................................... 3-38 FIGURE 3-4: TYPICAL IDU-C FRONT PANEL .............................................................................................. 3-38 FIGURE 3-5: AIND ALL INDOOR RADIO UNIT ............................................................................................ 3-38 FIGURE 3-6: POE-8 UNIT ............................................................................................................................ 3-39 FIGURE 3-7: O-POE UNIT ........................................................................................................................... 3-39 FIGURE 3-8: BEEPER SEQUENCE FOR ODU ALIGNMENT ............................................................................ 3-41 FIGURE 3-9: LINK INSTALLATION WIZARD ................................................................................................ 3-42 FIGURE 3-10: INSTALLATION WIZARD, SYSTEM DIALOG BOX .................................................................... 3-43 FIGURE 3-11: CHANGE LINK PASSWORD DIALOG BOX ............................................................................... 3-45 FIGURE 3-12: TYPICAL FRONT PANEL OF IDU-C ....................................................................................... 3-45 FIGURE 3-13: CHANNEL SELECT DIALOG BOX - AUTOMATIC CHANNEL SELECT ........................................ 3-47 FIGURE 3-14: BRS CHANNEL SETTINGS POST-TRANSITION ....................................................................... 3-50 FIGURE 3-15: INSTALLATION WIZARD, SERVICE DIALOG BOX ................................................................... 3-51 FIGURE 3-16: TDM PARAMETERS DIALOG BOX.......................................................................................... 3-54 FIGURE 3-17: EXTERNAL EQUIPMENT STATUS ........................................................................................... 3-55 FIGURE 3-18: TDM BACKUP SERVICE, IDU-R UNITS ONLY ....................................................................... 3-56 FIGURE 3-19: INSTALLATION WIZARD, FINISH SCREEN.............................................................................. 3-57 FIGURE 4-1: IDU-E FRONT PANEL ............................................................................................................. 4-59 FIGURE 4-2: LOGIN SCREEN ....................................................................................................................... 4-62 FIGURE 4-3: LOGIN SCREEN WITH COMMUNITY OPTIONS VISIBLE............................................................. 4-63 FIGURE 4-4: WINLINK 1000 MANAGER MAIN SCREEN .......................................................................... 4-64 FIGURE 4-5: OVER THE AIR CONNECTION .................................................................................................. 4-65 FIGURE 4-6: MAIN SCREEN, WIRELESS LINK IS ACTIVE ............................................................................. 4-65 FIGURE 4-7: ETHERNET BANDWIDTH INDICATION .................................................................................... 4-68 FIGURE 5-1: CONFIGURATION LINK WIZARD ............................................................................................ 5-70 FIGURE 5-2: LINK CONFIGURATION, SYSTEM DIALOG BOX ....................................................................... 5-71 FIGURE 5-3: CHANNEL SELECT DIALOG BOX - AUTOMATIC CHANNEL SELECT ......................................... 5-72 FIGURE 5-4: CHANNEL SELECT DIALOG BOX (DFS, ETSI REQUIREMENT)................................................. 5-73 FIGURE 5-5: BRS CHANNEL SETTINGS POST-TRANSITION ......................................................................... 5-75 FIGURE 5-6: SERVICES DIALOG BOX, E1/T1 INTERFACE............................................................................ 5-77 FIGURE 5-7: TDM CLOCK DIALOG BOX FOR T1 IDU ................................................................................. 5-78 FIGURE 5-8: TDM CLOCK DIALOG BOX FOR E1 IDU ................................................................................. 5-79 FIGURE 5-9: IDU-R - EXTERNAL EQUIPMENT STATUS ............................................................................... 5-81

WinLink User and Installation Guide

Version 1.750

1-9

FIGURE 5-10: CONFIGURATION LINK, FINISH SCREEN ............................................................................... 5-82 FIGURE 5-11: CONFIGURATION DIALOG BOX ............................................................................................ 5-84 FIGURE 5-12: CHANGING THE TRANSMIT POWER ...................................................................................... 5-85 FIGURE 5-13: MANAGEMENT ADDRESSES - SITE CONFIGURATION DIALOG BOX ........................................ 5-86 FIGURE 5-14: CONFIGURING VLAN SETTINGS........................................................................................... 5-87 FIGURE 5-15: NTP SERVER ADDRESS - SITE CONFIGURATION DIALOG BOX .............................................. 5-89 FIGURE 5-16: CHANGE DATE AND TIME - HQ DIALOG BOX........................................................................ 5-89 FIGURE 5-17: BRIDGE CONFIGURATION - SITE CONFIGURATION DIALOG BOX ........................................... 5-90 FIGURE 5-18: JITTER BUFFER CONFIGURATION .......................................................................................... 5-93 FIGURE 5-19: CHANGING THE COMMUNITY STRING ................................................................................... 5-95 FIGURE 5-20: ALTERNATIVE COMMUNITY DIALOG BOX ........................................................................... 5-96 FIGURE 5-21: EXTERNAL ALARM CONFIGURATION .................................................................................. 5-97 FIGURE 5-22: INVENTORY SCREEN .......................................................................................................... 5-100 FIGURE 5-23: TELNET MANAGEMENT SCREEN ........................................................................................ 5-102 FIGURE 6-1: GET LINK INFORMATION DIALOG BOX................................................................................. 6-104 FIGURE 6-2: LOOPBACK DIALOG BOX ....................................................................................................... 6-106 FIGURE 6-3: LOCAL EXTERNAL LOOPBACK ............................................................................................. 6-107 FIGURE 6-4: REMOTE INTERNAL LOOPBACK ............................................................................................ 6-107 FIGURE 6-5: REMOTE EXTERNAL LOOPBACK ........................................................................................... 6-108 FIGURE 6-6: LOCAL INTERNAL LOOPBACK.............................................................................................. 6-108 FIGURE 6-7: WINLINK 1000 - LINK BUDGET CALCULATOR ................................................................. 6-110 FIGURE 6-8: PREFERENCES DIALOG BOX .................................................................................................. 6-111 FIGURE 6-9: PERFORMANCE MONITORING REPORT WINDOW .................................................................. 6-112 FIGURE 6-10: THRESHOLD CONFIGURATION DIALOG BOX ........................................................................ 6-116 FIGURE 6-11: EVENTS LOG DISPLAY ........................................................................................................ 6-118 FIGURE 6-12: PREFERENCES DIALOG BOX ................................................................................................ 6-119 FIGURE 6-13: ACTIVE ALARMS SUMMARY............................................................................................... 6-121 FIGURE 8-1: ONLINE HELP FOR WINLINK 1000........................................................................................130 FIGURE 9-1: EXAMPLE FOR CONNECTING THE ALARM CONNECTOR .............................................................134 FIGURE 10-1: LARGE CLAMP ................................................................................................................. 10-138 FIGURE 10-2: SMALL CLAMP ................................................................................................................. 10-138 FIGURE 10-3: ARM ................................................................................................................................. 10-138 FIGURE 10-4: MOUNTING ON A MAST .................................................................................................... 10-139 FIGURE 10-5: MOUNTI NG ON A WALL ................................................................................................... 10-140 FIGURE 11-1: WINLINK LINK SETUP ...................................................................................................... 11-142 FIGURE 13-1: INTERFERENCE CAUSED BY COLLOCATED UNITS .............................................................. 13-148 FIGURE 13-2: COLLOCATED UNITS USING HUB SITE SYNCHRONIZATION ............................................... 13-149 FIGURE 13-3: COLLOCATION SITE CALCULATOR ................................................................................... 13-149 FIGURE 13-4: HSS INTERCONNECTION UNIT ......................................................................................... 13-150 FIGURE 13-5: HSS TYPICAL APPLICATION ............................................................................................. 13-152 FIGURE 13-6: HUB SITE SYNCHRONIZATION SETTINGS DIALOG BOX..................................................... 13-153 FIGURE 13-7: HUB SITE CONFIGURATION DIALOG BOX .......................................................................... 13-155 FIGURE 13-8: SITE CONFIGURATION HUB SITE SYNC DIALOG BOX ..................................................... 13-156 FIGURE 13-9: HSS NOT SUPPORTED ...................................................................................................... 13-157 FIGURE 14-1: INACTIVE MANAGER SCREEN ........................................................................................... 14-158 FIGURE 14-2: BRS AIR INTERFACE DIALOG BOX .................................................................................... 14-159 FIGURE 14-3: BRS CHANNEL SETTINGS PRE-TRANSITION ..................................................................... 14-160 FIGURE 14-4: BRS CHANNEL SETTINGS POST-TRANSITION ................................................................... 14-161 FIGURE 16-1: ACCESSING THE LINK BUDGET MANAGER CALCULATOR................................................. 16-163 FIGURE 16-2: LINK BUDGET SCREEN ..................................................................................................... 16-165 FIGURE 16-3: CLIMATE AND TERRAIN FACTOR ...................................................................................... 16-165 FIGURE 16-4: GEOGRAPHICAL CONDITIONS ........................................................................................... 16-166 FIGURE 16-5: FRESNEL ZONE ................................................................................................................. 16-166

WinLink User and Installation Guide

Version 1.750

1-10

List of TablesTABLE 2-1: ODU SERIES TYPICAL CHARACTERISTICS ............................................................................... 2-22 TABLE 2-2: CONFIGURABLE TRANSMISSION OPTIONS ................................................................................ 2-25 TABLE 2-3: RATES AND SERVICES SUPPORTED .......................................................................................... 2-25 TABLE 2-4: RADIO REGULATIONS .............................................................................................................. 2-26 TABLE 2-5: ENVIRONMENTAL REGULATIONS ............................................................................................. 2-26 TABLE 2-6: TECHNICAL SPECIFICATION SUMMARY ................................................................................... 2-28 TABLE 3-1: RATES PER BANDWIDTH .......................................................................................................... 3-52 TABLE 3-2: TDM CLOCK MODES ............................................................................................................... 3-53 TABLE 4-1: FRONT PANEL LEDS................................................................................................................ 4-59 TABLE 4-2: ODU/LAN LEDS .................................................................................................................... 4-59 TABLE 4-3: TDM TRAFFIC INDICATORS ..................................................................................................... 4-60 TABLE 4-4: WINLINK INDICATORS AT STARTUP ........................................................................................ 4-60 TABLE 4-5: DEFAULT SETTINGS ................................................................................................................. 4-61 TABLE 5-1: TDM CLOCK MODES .............................................................................................................. 5-80 TABLE 5-2: TELNET COMMANDS ............................................................................................................. 5-101 TABLE 6-1: GET LINK INFORMATION DATA AND DESCRIPTION ............................................................... 6-103 TABLE 6-2: LINK COMPATIBILITY TRAP MESSAGES ................................................................................ 6-105 TABLE 6-3: EXPLANATION OF PERFORMANCE DATA................................................................................ 6-113 TABLE 6-4: ACTION OF THE TOOLBAR BUTTONS...................................................................................... 6-115 TABLE 6-5: ALARMS AND INFORMATION MESSAGES .............................................................................. 6-117 TABLE 6-6: ACTIVE ALARMS COMMAND BUTTONS .................................................................................. 6-121 TABLE 8-1: TROUBLESHOOTING ..................................................................................................................125 TABLE 8-2: TROUBLESHOOTING WITH LEDS ..............................................................................................125 TABLE 9-1: ODU-IDU CONNECTOR PINOUT...............................................................................................131 TABLE 9-2: E1/T1 CONNECTOR PINOUT ......................................................................................................132 TABLE 9-3: FAST ETHERNET CONNECTOR PINOUT ......................................................................................132 TABLE 9-4: FAST ETHERNET CONNECTOR PINOUT ......................................................................................132 TABLE 9-5: TERMINAL BLOCK 3-PIN -48VDC.............................................................................................133 TABLE 9-6: IDU-C ALARM CONNECTOR (DRY-CONTACT) .........................................................................134 TABLE 9-7: POE ALARM CONNECTOR (DRY-CONTACT) .............................................................................135 TABLE 9-8: ALARM CONNECTOR (DRY-CONTACT).....................................................................................135 TABLE 9-9: O-POE TO PC CABLE CONNECTOR PINOUT ..............................................................................137 TABLE 12-1: ANTENNA CHARACTERISTICS ........................................................................................... 12-146 TABLE 13-1: ODU/HSS CONNECTION PINOUT ...................................................................................... 13-151 TABLE 13-2: RADIO FRAME PATTERN TABLE ....................................................................................... 13-152 TABLE 13-3: EXTERNAL PULSE STATUS ................................................................................................. 13-154 TABLE 15-1: RF EXPOSURE .................................................................................................................... 15-162 TABLE 17-1: PRODUCT SPECIFICATION TABLE ....................................................................................... 17-168

WinLink User and Installation Guide

Version 1.750

1-11

Chapter 1

IntroductionRADWIN's WinLink1000 family of wireless broadband products deliver carrier-class performance at the most competitive price. WinLink1000 products pack legacy TDM and Ethernet services over the 2.3 - 2.7 GHz and 4.9 - 5.95 GHz spectrum bands, and comply with worldwide standards and regulations (including FCC and ETSI). RADWIN's carrier-class WinLink 1000 products meet the stringent performance and quality demands of cellular carriers and service providers. Delivering high capacity connectivity of up to 48 Mbps at distances of up to 80 Km/50 miles, the WinLink 1000 products offer an unmatched combination of robustness and reliability at an affordable price.

Key ApplicationsRADWIN's WinLink 1000 systems are ideally suited to meet the needs of cellular carriers, service providers and private networks (such as private and public enterprises, government, educational and financial institutions). The WinLink1000 systems power a range of applications, among them: Cellular Backhaul Broadband Access Private Network Connectivity Video Surveillance

Cellular BackhaulWinLink 1000 products enable cellular carriers to expand their networks in both urban and rural areas quickly and cost-effectively. WinLink 1000 systems are ideally suited for a broad range of cellular backhaul deployment scenarios; they empower carriers to expand their presence into remote and low ARPU areas, provide enhanced overlay coverage in urban spots, and can serve as a temporary or backup backhaul solution.

Key Applications

Figure 1-1: Typical Cellular Backhaul Application

Broadband AccessWith WinLink 1000, service providers can expand their service footprint rapidly and affordably, and provide high-capacity services that match the ever-growing demand for high-quality, high-speed broadband. WinLink 1000 is the ideal solution for last mile access, and also powers WiFi backhaul and WMAX backhaul applications.

Figure 1-2: Typical Broadband Access Application

WinLink User and Installation Guide

Version 1.750

1-13

Key Applications

Figure 1-3: Typical WiFi Backhaul Application

Private NetworksWinLink 1000 is the perfect solution for private networks such as enterprises, education, government and utility organizations that want to own and control their networks and eliminate the high recurring charges for leased lines/cable. RADWINs cost-effective solution enables organizations of all types to connect geographically dispersed buildings at ranges of up to 80 Km/50 miles.

Figure 1-4: Multi Point-to-Point Enterprise ConnectivityWinLink User and Installation Guide Version 1.750 1-14

WinLink 1000 Key Features

Video SurveillanceRADWIN's WinLink 1000 wireless broadband systems allow organizations and system integrators to deploy video cameras virtually anywhere while eliminating the costs and installation hassles of wirebased systems. Reliable, robust and affordable, the WinLink 1000 systems support a variety of transmission topologies such as Ring, Star and Daisy Chain to provide surveillance coverage of the most challenging environments.

Figure 1-5: Multi Point-to-Point Video Surveillance Deployment

WinLink 1000 Key FeaturesThe following represents some of the outstanding features that WinLink 1000 provides:

TDM + Ethernet in one SolutionWinLink 1000 systems deliver carrier-class TDM + Ethernet over one platform, making them ideal for a range of backhaul and access applications.

Simple InstallationWinLink 1000 systems are extremely simple to install and maintain, and are typically up and running in less than an hour.

Advanced Air InterfaceThe WinLink 1000 system design incorporates an exceptionally robust air interface based on patented technologies. The unique air WinLink User and Installation Guide Version 1.750 1-15

How to Use this Manual

interface protocol of WinLink 1000 is designed to ensure non-stop, high quality transmission, even when encountering interference and harsh conditions.

Automatic Adaptive RateAutomatic Adaptive Rate is a method of dynamically adapting the transmitted rate by changing both the signal modulation and coding. Automatic Adaptive optimizes the data throughput according to interference conditions, to optimize data throughput while maintaining service quality.

Unique Multi Point-to-Point DeploymentRADWIN's WinLink 1000 products can be installed in a unique multi point-to-point architecture. Multiple units are deployed in one hub site location, from where they provide a dedicated, high-capacity connection to each remote site. This unique concept builds on RADWIN's Hub Site Synchronization (HSS) feature, which synchronizes the transmission of collocated WinLink 1000 units, thus virtually reducing mutual interference commonly experienced with collocated TDD radios.

Enhanced Air Interface SecurityWinLink 1000s AES 128-bit key encryption provides enhanced air interface security.

Advanced Management and Performance MonitoringThe WinLink 1000 Manager software has full local and remote management capabilities. The user-friendly SNMP-based management tool provides full end-to-end configuration, event log, and performance monitoring capabilities.

How to Use this ManualThis manual (WinLink User Manual and Installation Guide version 1.750) contains instructions for both setting up and managing the WinLink 1000 system. The following topics are covered: WinLink 1000 Hardware Installation WinLink 1000 Manager Software Installation Controlling and Monitoring the System Using the WinLink 1000 Manager Troubleshooting

WinLink User and Installation Guide

Version 1.750

1-16

How to Use this Manual

It is recommended that you first read the Overview in the next chapter as this provides an understanding of the various parts of the system and how the system works.

WinLink User and Installation Guide

Version 1.750

1-17

Chapter 2

OverviewWinLink 1000 System ComponentsWinLink 1000 point-to-point solution is made up of a number of key components. Typically, each side of the link comprises an Indoor Unit (IDU), an Outdoor Unit (ODU) and an antenna. A CAT5e cable from the IDU to the ODU provides both Ethernet and Power. The link is managed via the WinLink 1000 Manager application.

Figure 2-1: Example of Link Architecture

WinLink 1000 System Components

The Indoor Unit (IDU)The IDU provides TDM and Ethernet ports to connect to the link. It also provides power to the ODU. The IDU is available in four configurations:

IDU-EA compact, half 19 inch wide, 1U plastic unit, providing up to two Ethernet ports and up to two E1/T1 interfaces.

Figure 2-2: IDU-E Front Panel

Figure 2-3: IDU-E Back Panel

IDU-CA 19 inch, 1U metal unit, providing two Ethernet ports, 4xE1/T1 interfaces, and dry contact connector alarm.

Figure 2-4: IDU-C Front Panel

IDU-RA compact, half 19 inch, 1U plastic unit for 1 x T1/E1 backup, providing in addition 2 Ethernet ports and an external alarms interface. IDU-R is an indoor unit used for automatic backup of leased lines. IDU-R monitors the status of leased lines, and in the event of a connection failure automatically switches to the radio link. The user configures which of the two links is the main link and which is the backup link. IDU-R operates with all WinLink 1000 outdoor units.

Figure 2-5: IDU-R Front PanelWinLink User and Installation Guide

Figure 2-6: IDU-R Back PanelVersion 1.750 2-19

WinLink 1000 System Components

Figure 2-7: Backup link for E1/T1 connections

Power Over Ethernet UnitsPower over Ethernet units provide Ethernet services only.

Power over Ethernet (PoE)An extremely compact device, the Power Over Ethernet (PoE) provides Ethernet only services through one Ethernet port.

Figure 2-8: PoE1.

Note: The PoE can only be connected to ODUs that are PoE enabled, or that are High End or Access ODUs. PoE8A 19 inch, 1U metal unit providing 8 Ethernet ports enabling connection to collocated Ethernet applications.

WinLink User and Installation Guide

Version 1.750

2-20

WinLink 1000 System Components

O-PoESimilar to the PoE, with weatherproof casing and sealed connectors that enables outdoor connectivity (a special mounting kit is supplied for attachment to a mast).

Figure 2-9: O-PoE Unit

The Outdoor Unit (ODU)The ODU is the radio transceiver of the WinLink system and is the main component of the system. The ODU connects to an antenna that enables radio communication and can be mounted on a pole or wall. The ODU connects to the IDU via a CAT5e cable. ODUs are available in different frequencies and regulations in the ranges: 2.3-2.7GHz, 4.9-5.95GHz. The ODU comes in two different form factors depending on the type of antenna: ODU with integrated 1ft flat panel antenna. This unit contains both the ODU and antenna as a single unit housed in a weatherproof casing. ODU with a connector for an external antenna. The unit is fitted with an N-type connector. An external antenna can extend the range of the link, and in some cases, may help to reduce environmental interferences.

Various external antennas are available for the WinLink 1000 operating frequencies.

Figure 2-10: ODU with integrated antennaWinLink User and Installation Guide Version 1.750 2-21

WinLink 1000 System Components

Figure 2-11: Typically used External AntennasThere are three series of ODU: WinLink 1000 Access WinLink 1000 WinLink 1000 High End

The following table shows the differences between the systems:

Table 2-1: ODU Series Typical CharacteristicsWinLink 1000 Access Max Ethernet Throughput Max. Range Supported IDU devices Services HSS Tx PW 2Mbps 20Km PoE Ethernet + 18 dBm WinLink 1000 18Mbps 80Km PoE and IDU Ethernet and TDM 18 dBm WinLink 1000 High End 18Mbps 80Km PoE and IDU Ethernet and TDM + 23 dBm

WinLink User and Installation Guide

Version 1.750

2-22

WinLink 1000 System Components

WinLink 1000 ManagerThe WinLink 1000 Manager is an SNMP based element and link management application which manages a complete link via a single IP address. It identifies the IP Address, Subnet Mask, and Trap Destination for each Site and also monitors the Radio Interface RSS [dBm] and Ethernet Service Rx Rate and Tx Rate. The Manager software facilitates the Link installation and Link configuration between the ODU units. The intuitive, easy-to-use Manager has a graphical MSWindows interface, and can be utilized locally and remotely. WinLink 1000 Manager provides: Planning tools such as a Link Budget calculator for calculating the expected performance of the WinLink wireless link and the possible configurations for a specific link range. Installation Wizard On-line monitoring of air interface quality allowing the administrator to monitor the service and status of each link. On-line monitoring of equipment alarms and QoS Local and remote loopback testing Configuration settings On-line user manual and help files Over-the-air software upgrades

The WinLink 1000 Manager can easily be integrated with any NMS system.

Figure 2-12: WinLink 1000 Manager screenWinLink User and Installation Guide Version 1.750 2-23

WinLink 1000 System Components

(All Indoor Unit) AINDThe AIND - All Indoor unit offers a single enclosure for Radio and Multiplexer modules. It enables outdoor placement of only a passive element.

Figure 2-13: AIND - "All Indoor" unit connected to antenna

WinLink User and Installation Guide

Version 1.750

2-24

Technical Specifications

Technical SpecificationsAir InterfaceWinLink is available in several different frequency band ranges that comply with ETSI, FCC and IC regulations.

Frequency Bands and Channel BandwidthTable 2-2: Configurable Transmission Options5.850-5.950 GHz 5.725-5.850 GHz Frequency Bands 5.470-5.725 GHz 5.150-5.350 GHz 4.940-4.990 GHz 2.500-2.700 GHz 2.400-2.4835 GHz 2.300-2.340 GHz / 2.310-2.485 GHz Channel Bandwidth Transmit Power Duplex Technique Sensitivity (dBm) @BER WinLink 1000 Manager. The Login dialog box appears.

WinLink User and Installation Guide

Version 1.750

4-61

Starting the WinLink Manager Software

Figure 4-2: Login Screen3. For IP Address do one of the following: Type an IP address for the ODU (for Network mode), OR Click Local Connection (if you are connected directly to the IDU LAN port).

The default IP address for the ODU is 10.0.0.120. The Subnet mask is 255.0.0.0. For Versions 1.700 and greater, any valid subnet mask may be used. 4. Enter the password1.

Note: The actual IP address is defined during link configuration (see Defining the Management Addresses).Default password admin (see the section on Changing the Management Password) 5. If you are a user with Read-Write permission, click Options to enter the community options. WinLink 1000 is protected with Community passwords. A user may be defined with read-only permission or with read-write permission. See the section Changing Community Values for more detail.

WinLink User and Installation Guide

Version 1.750

4-62

Starting the WinLink Manager Software

Figure 4-3: Login Screen with Community Options Visible If using the system for the first time, leave the default community passwords, netman for read-write, and public for read-only. If community values were previously defined, enter them under Community in the Read-Only or Read-Write boxes. If you are a user with read-only permission, click the Read Only Mode check box.

The WinLink 1000 Manager main screen is displayed (see Figure

4-4).

Note: With BRS systems the link must be activated at both sites when installing for the first time. A red Inactive Link box appears in the center of the Manager screen. Activation is performed later.

WinLink User and Installation Guide

Version 1.750

4-63

Starting the WinLink Manager Software

Figure 4-4: WinLink 1000 Manager Main Screen

Over the Air Connection indicationDuring the login the Manager reports on over the air connection.

Note: Over the Air connection to remote unit is not recommended Select the relevant option for your login requirements.

WinLink User and Installation Guide

Version 1.750

4-64

Managing WinLink

Figure 4-5: Over the Air Connection

Managing WinLinkBefore starting a management session, make sure that a communication link between local and remote units exists. The Link Status indication bar in the middle of the Main menu must be green and the Radio Link - Sync message must appear in the event log (see Figure 4-6).

Figure 4-6: Main Screen, Wireless Link is ActiveThe WinLink 1000 Manager Main screen consists of the following elements: WinLink User and Installation Guide Version 1.750 4-65

Managing WinLink

Toolbar buttonsLink Configuration Changes configuration parameters of operating wireless link; assigns text files for storing alarms, statistics and configuration data Performs preliminary configuration of the system This button is disabled once a link is defined. Clears error counters (available with TDM only) Logs off WinLink 1000 Manager Exits WinLink 1000 Manager

Link Installation

Clear Counters Log off Exit

Menu barFile Configuration Tools Log off, and exit Use for link configuration, individual site configuration or link installation Acesses Performance Monitoring Report, Active Alarms, Change password, Event log handling, Set Preferences Provides the following functions: Clear counters, Loopbacks, System Reset. Provides WinLink Manager Help, Link Budget Calculator, Get Link Information About WinLink

Maintenance Help

Link details pane Summarizes information on the radio frequency, IP address, type of TDM service, number of assigned E1 or T1 timeslots, and IP details of the local and remote WinLink units. Displays the link quality between local and remote devices and the following statistics: Radio signal strength (RSS) in dBm Current Ethernet bandwidth in Mbps. This is not the actual traffic rate, but the maximum capacity (Net symmetrical Throughput Full-Duplex) that can be supported currently, (see Figure 4-7). The scale on the bar varies depending on the link distance and air interface quality. Local/remote receive and transmit traffic rate, in Mbps or Fps (frames per second).

Monitor pane

WinLink User and Installation Guide

Version 1.750

4-66

Managing WinLink

TDM status The Estimated Time Between Errors bar gives an indication of the TDM quality. The ETBE constantly calculates the expected TDM ratio according to the current air interface conditions. Link Status: Shows the channel frequency. The color of the box indicates the status. Green is an active link Red is an inactive link Magenta shows an authentication or compatibility problem Brown shows severe compatibility problem. Event log stores alarms generated by local and remote units.

Status Bar Displays the following icons: Connectivity icon showing how the device is connected to the Ethernet. Network connection to the local unit using IP of the local unit Over the Air connection - using IP address of the remote for over the air connection Local mode using broadcast - direct connection to IDU LAN port without IP address. This mode is only recommended when the managed PC is connected directly to the IDU (no network involved) the managed PC must have a static IP configured. (No DHCP) Encryption icon showing if the link is encrypted encrypted link Link Password Validation failed. The link is encrypted with default keys. Service and configuration is unavailable. Need to change the link password in either site No Encryption an older release is used. No encryption is available

WinLink User and Installation Guide

Version 1.750

4-67

Managing WinLink

Figure 4-7: Ethernet Bandwidth IndicationTo change link configuration parameters: 1. In the Main menu, click Configure Link. The Configure Link wizard appears. See Link Configuration Wizard for configuration details. 2. Click Next. 3. Continue through the configuration wizard and define the Link name and ID, Channel, Rate and Services. 4. Once you finish changing configuration parameters, click Finish. The system takes a few seconds to activate the link with the new configuration.

Turning Off WinLinkTo turn off WinLink: 1. Exit the management application. 2. Remove the AC/DC converter power cord from the mains.

WinLink User and Installation Guide

Version 1.750

4-68

Chapter 5

Configuring the LinkThis chapter describes configuration procedures, which are performed after the physical installation of the local and remote WinLink units and after the Installation Link wizard has been run. A Link Configuration wizard is used to redefine the configuration parameters if necessary. Both the HQ and sites in the link are defined simultaneously (both sides of the link are defined simultaneously). The following parameters are configured via the Site Configuration Wizard: System parameters Frequency channel Air interface rate Service parameters TDM Hub Site Synchronization Settings. Transmit power Management and trap addresses Bridge mode Ethernet mode Community values.

The following parameters are configured via the Configuration dialog box.

For HSS screens see Appendix E: Hub Site Synchronization. After installing the link, the system configuration can be modified.

Link Configuration Wizard

Link Configuration WizardConfiguring System ParametersTo change general parameters: 1. In the Main menu, click the Link Configuration button. The Configuration wizard opens:

Figure 5-1: Configuration Link Wizard2. Click Next. The Link Configuration dialog box appears:

WinLink User and Installation Guide

Version 1.750

5-70

Link Configuration Wizard

Figure 5-2: Link Configuration, System dialog box3. In the System dialog box, enter the new data for the link. All fields with a white background can be edited. 4. Click Next. The Channel Settings dialog box appears.

Selecting Channels: Automatic Channel SelectYou are required to define the operating frequency channel. Newer versions have a feature called Automatic Channel Select (ACS). This allows you to define several allowable frequency channels to which you can change if interference is detected on the channel in use. ACS performs channel monitoring and selects the channel with the lowest interference for the transmission. Automatic Channel Select enables coexistence with any radar system that may be active in the area. Note: For the ETSI version, skip to page 5-73; for the BRS version, skip to page 5-75.

WinLink User and Installation Guide

Version 1.750

5-71

Link Configuration Wizard

Figure 5-3: Channel Select dialog box - Automatic Channel SelectTo define automatic channel selection: 1. Select the main frequency from the Operating Channel menu. 2. Select the required Bandwidth 5, 10, or 20 MHz. 3. Click the check box if Automatic Channel Selection is required. 4. Click the check boxes in the Available Channels List of all the allowable channels that can be automatically selected. 5. If you are not satisfied with the channel that is selected automatically, click Reselect Channel. A new channel will be selected from one of the Available Channels that have been defined.

Note: By clicking Reselect Channel, the ODU scans the selected channels looking for radio frequency activity. Once it determines which of the channels is free of RF signal activity, it locks onto it. If you require a different channel than the one selected, you must first remove theWinLink User and Installation Guide Version 1.750 5-72

Link Configuration Wizard

operating channel that the ODU finds most free of RF signal activity from the available channel list.6. Click Next. The Rate Select box appears. Note: If you have the standard version, proceed to Configuring Service Parameters, page 5-76. For the ETSI version, proceed to the next section; for the BRS version, skip to page 5-75.

The 5.4 GHz ETSI VersionIn accordance with ETSI, unlicensed wireless data equipment is not allowed to interrupt radar services. Therefore, if the ETSI Version detects Radar activity, it automatically changes the frequency channel. This feature is termed Dynamic Frequency Selection (DFS). According to the standard, a channel with active Radar is prohibited from use for 30 minutes. Before any transmission, WinLink probes a channel for Radar signals for a period of 60 seconds. In the 5.4 GHz ETSI version, the Automatic Channel Selection is selected by default and a minimum of two channels must be defined as available.

Figure 5-4: Channel Select dialog box (DFS, ETSI requirement)WinLink User and Installation Guide Version 1.750 5-73

Link Configuration Wizard

The sign on the configuration Wizard and Status bar indicates that the radar detection is on. To define automatic channel selection in the 5.4 ETSI version 1. Select the main frequency from the Operating Channel menu.

Note: Automatic Channel Selection is selected by default.2. Click at least two check boxes in the Available Channels List of all the allowable channels that can be automatically selected.

Note: Installation will not continue until at least two channels are defined.Selecting a new channel causes the system quality to change. The quality bar shows the adjustment until the system finds the best quality link. Any channel selected is evaluated for 60 seconds; therefore this selection process may take a few minutes. 3. If you are not satisfied with the channel that is selected automatically, click Reselect Channel. A new channel will be selected from one of the Available Channels that have been defined.

Note: The reselection process may take a few minutes.4. Click Next. The maximum rate is selected according to the link conditions The quality bar may fluctuate until the system finds the best quality link. 5. Click Next. The Service Parameters dialog box appears. Proceed to page 5-76.

WinLink User and Installation Guide

Version 1.750

5-74

Link Configuration Wizard

BRS Version: Configuring BRS Channel SettingsNote: Both sites in a BRS Link must be configured identically.

To Configure BRS Channel Settings 1. Select the Band Plan: Pre-Transition or Post-Transition. 2. Select the Bandwidth required. Single Band (5MHz) Double Band (10MHz) Quad Band (20MHz)

3. Select the Frequency. 4. Click Next. The system is re-synchronized to the changes.

Figure 5-5: BRS Channel Settings Post-Transition

WinLink User and Installation Guide

Version 1.750

5-75

Link Configuration Wizard

Configuring Service ParametersYou define the type of service required, Ethernet Only or Ethernet with TDM. The bandwidth remaining available for Ethernet if TDM services are required is shown in the dialog box.

Note: ACCESS versions are Ethernet Only.In the Service Parameters dialog box select the number of E1 connections (x1 or x2 for IDU-E, or x4 for IDU-C). Define the required transmission rate, and the distance between the sites. To configure E1/T1 and Ethernet services: 1. In the Service dialog box, select one of the following: Ethernet plus a number of E1/T1 channels (see Figure 5-6). Ethernet data only. Adaptive 9 Mbps 12 Mbps 18 Mps 24 Mbps 36 Mbps 48 Mbps

2. Select the transmission rate required.

The default rate is Adaptive. ACCESS versions only operate in Adaptive mode. Adaptive Modulation - The system changes modulation automatically depending on channel characteristics in order to guarantee continuation of service. The adaptive modulation enables the user to maximize Ethernet throughput without degradation of the TDM service quality. When Ethernet only service is used, the adaptive modulation enables improving the Ethernet performance in case of air performance degradation (periodical interference or RSS changes). In event of interference at one site, there is no need to use a lower modulation at the other site (as in previous versions). In such a case the actual rate changes automatically only at the problematic

WinLink User and Installation Guide

Version 1.750

5-76

Link Configuration Wizard

site, while the second side of the link maintains the highest rate possible (Asymmetric). Adaptive modulation can be changed in both Installation and Configuration wizards. For versions 1.6 and greater, distance between the sites is automatically measured. If TDM services are selected, then the Evaluate icon shows on the screen while the maximum rate is evaluated. When evaluation is complete the icon changes and the following message is shown: Service has been evaluated, click Next to continue. 3. Click Next. The TDM Parameters dialog box or the Finish screen appears depending on which services were selected.

Figure 5-6: Services Dialog Box, E1/T1 Interface

WinLink User and Installation Guide

Version 1.750

5-77

Link Configuration Wizard

Configuring TDM OperationSetting the Clock ConfigurationThe TDM clock feature is enabled for carrier class IDU-C in addition to the hardware version 2 and greater IDU-E with TDM. A TDM dialog box will appear where IDU supports the clocking configuration feature (see Figure 5-7 and Figure 5-8). A new master clock configuration option is available in the Link Configuration Wizard. The automatic mode selects the clock from the first trunk that is working in normal mode (or is configured to loopback maintenance). If a specific trunk is selected, this trunk shall be used as the system master regardless of the trunks state. The current master clock trunk is also displayed.

Figure 5-7: TDM clock dialog box for T1 IDU

WinLink User and Installation Guide

Version 1.750

5-78

Link Configuration Wizard

Figure 5-8: TDM clock dialog box for E1 IDUIf TDM services are selected then the TDM parameters dialog box appears. The TDM Parameters dialog box contains five working modes; select the appropriate clock mode according to your application. Choosing one of these modes sets the TDM clock behavior on both sides of the link. The user equipment must be configured as described in Chapter 3.

WinLink User and Installation Guide

Version 1.750

5-79

Link Configuration Wizard

Transparent/Transparent WinLink regenerates the clock from line clock side to Tx clock on the opposite side of the link. Loop time/Recover The local unit receive clock is the transmit clock on both sides of the link. Recover/Loop time The remote unit receive clock is the transmit clock on both sides. Internal/Recover The local unit internal oscillator generates the clock while the remote unit recovers this clock. Recover/Internal The remote unit internal oscillator generates the clock while the local unit recovers this clock.

Note: The Line code option is used with T1 Systems. Table 5-1: TDM Clock ModesUnit Clock Mode Local Unit 1 2 3 4 5 Transparent Loop Time Recover Internal Recover Remote Unit Transparent Recover Loop Time Recover Internal User Equipment Side HQ side Internal/Recover Internal Recover Recover Recover Branch side Internal/Recover Recover Internal Recover Recover

Setting the T1 Line CodeThe T1 line code can be set as B8Zs or AMI in the TDM Parameters dialog box. The default is B8ZS.

Note: This dialog box is available only when TDM service was selected in the previous Services dialog box.

WinLink User and Installation Guide

Version 1.750

5-80

Link Configuration Wizard

To change the line code 1. Run the Configuration wizard until you reach the Services dialog box. 2. Verify that T1 services have been selected. 3. Click Next to open the TDM Parameters dialog box. 4. Set the line code to B8ZS or AMI as required. 5. Click Next.

Setting the TDM Backup (IDU-R only)The IDU-R units have two E1/T1 trunk lines, one for WinLink air interface via the ODU, and the second external is for peripheral equipment- I.E. PBX. The external equipment status is displayed on the Main screen of the Manager in IDU-R systems.

Figure 5-9: IDU-R - External Equipment StatusTo use the Backup Mode 1. Click Enabled Backup Mode. 2. Set which link is backup link; either the link or the external equipment. The second link becomes the main link. 3. Click Next to continue. To disable the Backup mode 1. Click Disable Backup Link 2. Set which link is the Main Link; either the link or the external equipment. 3. Click Next to continue.

WinLink User and Installation Guide

Version 1.750

5-81

Configuring the Site

Figure 5-10: Configuration Link, Finish screenThe Finish screen appears, showing a summary of the link configuration (see Figure 5-10) above. 4. Click Finish to complete the configuration wizard. The Main screen is displayed.

Configuring the SiteEditing the Configuration Parameters by SiteYou can edit the configuration parameters for each site individually. The following functions are available from either the left side of the dialog box, or the buttons on the top of the dialog box (see Figure 5-11).

Functions on the left of the dialog box:System Air Interface WinLink User and Installation Guide Edit the contact person and location details. View the system details Change the transmit power Version 1.750 5-82

Configuring the Site

Inventory Management Security Date and Time Advanced

View the hardware and software inventory. Configure the IP address, Subnet Mask, Default Gateway, and the Trap Destination. Change the Community Values and the Link Password Set the date and time of the server and of the System. Configure the Bridge, define the LAN connection and set the external alarm inputs.

Functions at the top of the dialog box:Backup Restore Installation Mode Save a backup.ini file with the current configuration. Load the backup.ini file created by the backup. Return to Installation Mode for the entire link. Selecting the Mute check box before clicking the Install Mode button mutes the Beeper. Mutes the alignment tone at startup. Reactivate the beeper during alignment.

Mute

To edit the Configuration Parameters: 1. Click Configuration from the main menu. 2. Select which site to configure. The Configuration dialog box opens. (See Figure 5-11)

WinLink User and Installation Guide

Version 1.750

5-83

Configuring the Site

Figure 5-11: Configuration Dialog Box3. Select the appropriate item in the left hand list to open a dialog box. 4. Click Apply to save changes.

Changing the Transmit PowerEach site can have a different transmit power level. To change the Transmit Power: 1. Click Configuration from the main menu. 2. Select which site to configure. The Configuration dialog box opens. 3. Select Air Interface. (See Figure 5-12) 4. Select the required Transmit Power Level. For available power limits for each system, see Appendix I - Product Specification Table, page 17-168. 5. Click Apply to save the changes.

WinLink User and Installation Guide

Version 1.750

5-84

Configuring the Site

Figure 5-12: Changing the Transmit Power

Defining the Management AddressesEach site must be configured separately, first site A then site B. To define the Management Addresses: 1. Click Configuration from the main menu. 2. Select which site to configure. The Configuration dialog box opens:

WinLink User and Installation Guide

Version 1.750

5-85

Configuring the Site

Figure 5-13: Management Addresses - Site Configuration dialog box3. Select Management. 4. Enter the IP address of the ODU in the IP address field.

Note: If performing configuration from the WinLink 1000 Manager, the IP address is entered in the login screen.5. Enter the Subnet Mask. 6. Enter the Default Gateway. 7. Enter the Trap Destination. This is the IP address of the PC running the management application. The event log will be stored at this address. 8. Click Apply to save the changes.

Configuring VLAN SettingsVLAN Management enables separation of user traffic from NMS Traffic. The user decides if such a separation is required. Both the HQ and Remote site are configured with VLAN Management.

WinLink User and Installation Guide

Version 1.750

5-86

Configuring the Site

To enable VLAN management: 1. Click Configuration from the main menu. 2. Select which site to configure (HQ or Remote site). 3. Select Management. 4. Open the VLAN tab. 5. Check The Enabled box. 6. Enter a VLAN ID. After entering the VLAN ID, only packets with the specified VLAN ID are processed by the ODU. This includes all the protocols supported by the ODU (ICMP, SNMP, TELNET and NTP). The VLAN priority is used for the traffic sent from the ODU to the management workstation. VLAN management affects all types of management connections (local, network and over the air). 7. Enter a Priority number.

Figure 5-14: Configuring VLAN Settings Changing this parameter causes the management application to immediately disconnect. In order to avoid problems, it is recommended to verify the change by setting the VLAN only to one ODU, and only after verifying the VLAN network operation, change the other VLAN setting can be changed.Version 1.750 5-87

Warning

WinLink User and Installation Guide

Configuring the Site

Troubleshooting: If the VLAN ID is forgotten or there is no VLAN network connected to the ODU: Reset the device. In the first two minutes both VLAN and no VLAN connections are available.

Setting the Date and TimeThe ODU maintains a date and time value. The date and time value should be synchronized with any Network Time Protocol (NTP) version 3 compatible server 1. On power-up the ODU configures the initial date and time using an NTP server. If the server IP is not configured or is not reachable, a default time is set. When configuring the NTP server IP, you should also configure the offset from the Universal Coordinated Time (UTC). If there is no server available, you can either set the date and time, or you can set the manager workstation time. Note that manual setting is not recommended since reset, power up, or synchronization with an NTP server will override the setting.

Note: The NTP uses UDP port 123. If a firewall is configured between the ODU and the NTP server this port must be opened 2. It can take up to 8 minutes for the NTP to synchronize the ODU date and time.To set Date and time 1. Click Configuration from the main menu. 2. Select which site to configure. The Configuration dialog box opens. 3. Select Date & Time:

1 2

Windows XP is configured by default as a server.

Windows XP command w32tm /stripchart /computer: can be use to check the NTP server connectivity

WinLink User and Installation Guide

Version 1.750

5-88

Configuring the Site

Figure 5-15: NTP Server Address - Site Configuration dialog box4. If entering an address for the NTP Server, click Clear, and then enter the new address. 5. Set the Offse