12
Us e PROMPT Flex - PPH Module limbsandthings.com r me sk train ucʦ t Limbs & Things Ltd. Sussex Street, St Philips, Bristol, BS2 0RA, UK E: [email protected] T: +44 (0) 117 311 0500 80101

User Guide PROMPT Flex - PPH Module · 4 Removing the Cervix To remove the Cervix, turn the securing bar 90˚ anti-clockwise to free the pelvic ring clamp 1 Remove the pelvic ring

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: User Guide PROMPT Flex - PPH Module · 4 Removing the Cervix To remove the Cervix, turn the securing bar 90˚ anti-clockwise to free the pelvic ring clamp 1 Remove the pelvic ring

User GuidePROMPT Flex - PPH Module

l imbsandthings.comFor more skills training products visit

Limbs & Things Ltd.Sussex Street, St Philips, Bristol, BS2 0RA, UKE: [email protected]: +44 (0) 117 311 0500

80101

Page 2: User Guide PROMPT Flex - PPH Module · 4 Removing the Cervix To remove the Cervix, turn the securing bar 90˚ anti-clockwise to free the pelvic ring clamp 1 Remove the pelvic ring

2

Index

• PROMPT Flex - PPH Module 3

• Removing the Cervix 4

• Fitting the PPH Module 5

• Attaching the Connectors 6

• Attaching the Abdomen 7

• Pressurizing Boggy Uterus 8

• Adding Blood to Uterus 8

• Using the Module 10

Page 3: User Guide PROMPT Flex - PPH Module · 4 Removing the Cervix To remove the Cervix, turn the securing bar 90˚ anti-clockwise to free the pelvic ring clamp 1 Remove the pelvic ring

3

PROMPT Flex - PPH Module

Allowing training in the management of post-partum bleeding, it offers a realistic simulation of an atonic and contracting uterus.

This module is an optional add-on for PROMPT Flex Standard or Advanced.

• Management of post-partum bleeding: - Fundal massage - Bi-manual compression - Haemostatic balloon insertion and management• Communication skills with mother when used

with Simulated Patient• Intramuscular injection• Estimating blood loss

Skills Product Qualities

Realism – Atonic uterus can simulate contraction on fundal massage

Key Features – Blood loss of up to 2 litres can be simulated – Air bulbs are used to stimulate blood flow and control atonic state of the uterus

Versatility – Can be quickly and easily fitted into the birthing mother to allow simulation of situations where bleeding occurs directly after delivery

80127 PROMPT Flex PPH Uterus Assembly

00020 Concentrated Venous Blood - Starter Pack (x2)

PROMPT Flex PPH blood container

Page 4: User Guide PROMPT Flex - PPH Module · 4 Removing the Cervix To remove the Cervix, turn the securing bar 90˚ anti-clockwise to free the pelvic ring clamp 1 Remove the pelvic ring

4

Removing the Cervix

To remove the Cervix, turn the securing bar 90˚ anti-clockwise to free the pelvic ring clamp

1

Remove the pelvic ring clamp, lifting the posterior end up and sliding the anterior end away from the pubic bone

2

Remove the Cervix from the model

3

The Cervix will need to be removed when fitting the PPH Module

Note: Reverse this process for fitting a Cervix

Page 5: User Guide PROMPT Flex - PPH Module · 4 Removing the Cervix To remove the Cervix, turn the securing bar 90˚ anti-clockwise to free the pelvic ring clamp 1 Remove the pelvic ring

5

Fitting the PPH Module

Place the PPH Module to the Birthing Mother, ensuring that Pelvic Ring Clamp sits under the pubic bone

1

Turn the securing bar clockwise so that it securely holds the module in place

2

Page 6: User Guide PROMPT Flex - PPH Module · 4 Removing the Cervix To remove the Cervix, turn the securing bar 90˚ anti-clockwise to free the pelvic ring clamp 1 Remove the pelvic ring

6

Attaching the Connectors

To attach the Air Feed, connect the air feed tube belonging to the separate air bulb to the upper, blue connector on the PPH module

1

To attach the Blood Feed, connect the Red connector on the blood container line to the lower, white connector on the PPH module

3

Turn clockwise to firmly secure

2

Turn clockwise to firmly secure

4

Page 7: User Guide PROMPT Flex - PPH Module · 4 Removing the Cervix To remove the Cervix, turn the securing bar 90˚ anti-clockwise to free the pelvic ring clamp 1 Remove the pelvic ring

7

Attaching the Abdomen

Attach the Abdomen by securing the skin to the pegs on the sides of the model

1

Attach the skin to the pegs at the front of the model to fully secure the Abdomen

2

Page 8: User Guide PROMPT Flex - PPH Module · 4 Removing the Cervix To remove the Cervix, turn the securing bar 90˚ anti-clockwise to free the pelvic ring clamp 1 Remove the pelvic ring

8

Pressurizing Boggy Uterus

Squeeze the air bulb several times to inflate the boggy uterus

2

Ensure that the air feed tube clamp is closed

1

Fill a jug of water and add to the blood concentrate until the bottle is filled to the advised line on the bottle

1

Ensuring the lip of the blood concentrate is secured firmly, tilt the bottle 2-3 times to mix the concentrate with the water

2

Adding Blood to Uterus

Page 9: User Guide PROMPT Flex - PPH Module · 4 Removing the Cervix To remove the Cervix, turn the securing bar 90˚ anti-clockwise to free the pelvic ring clamp 1 Remove the pelvic ring

9

Adding Blood to Uterus

Add the blood concentrate to the PPH Blood Resevior

3

Attach the lid firmly. It is easier to hold the lid in a fixed position and rotate the reservoir bottle until tight; this prevents tubes becoming tangled

4

Squeeze the air bulb until the blood starts to flow through the tubes and begin to fill the uterus, and blood runs out of the vagina. You may want to place an inco pad under the model to soak the blood up

5

Ensure the air release clip is now open

6

Page 10: User Guide PROMPT Flex - PPH Module · 4 Removing the Cervix To remove the Cervix, turn the securing bar 90˚ anti-clockwise to free the pelvic ring clamp 1 Remove the pelvic ring

10

Using the Module

Once the uterus has been successfully massaged, close the clamp on the blood flow tube to stop the flow of blood

2

Use an empty syringe to remove any excess blood from the vagina after the drill. It can be placed back into the blood concentrate bottle. Use tissue to wipe away any remaining blood drops

3

The uterus can now be massaged. Air will escape through the air release tube each time the uterus is massaged

1

Page 11: User Guide PROMPT Flex - PPH Module · 4 Removing the Cervix To remove the Cervix, turn the securing bar 90˚ anti-clockwise to free the pelvic ring clamp 1 Remove the pelvic ring

Notes

Page 12: User Guide PROMPT Flex - PPH Module · 4 Removing the Cervix To remove the Cervix, turn the securing bar 90˚ anti-clockwise to free the pelvic ring clamp 1 Remove the pelvic ring

Part No: 165-014Issue 2, June 2018© 2018 Limbs & Things

You may also be interested in...

To find out more visit:

PROMPT Flex - Caesarean Section Module

PROMPT Flex - Cervical Dilatation & Effacement

Product No: 80103

Product No: 80102

l imbsandthings.com