12
800.223.0483 | allcurrent.com For over 30 years we’ve served Electrical Distributors with Engineered Products and Need It Now service. Our experience enables us to provide Custom Assembled Products and Solutions... accurate, on-time results that exceed your expectations. U L US C LISTED UL 508A /698A Panel Shops New Jersey - Texas - California Master Distributor Services Engineering of Custom Control Systems Drilling and Tapping Services Assembly of Controls using Customer Supplied Components Breaker in-shop testing (NJ) Retrofit circuit breakers ATEX Rated Equipment Products Industrial Control Panels MCC Buckets Enclosed Motor Control Assembled Circuit Breakers Assembled Hazardous Location Controls, Switches and Circuit Breakers Industries Served Oil/Gas Chemical Onshore/Offshore Drilling Wastewater Treatment Pharmaceutical Food Processing Printing Mining CUSTOM ASSEMBLED PRODUCTS & SERVICES

US C LISTED C UL US service. LISTED UL C UL C UL US UL ... › customer › alcuel › customerpages › ... · 13 units 14 units 15 units 17 units 20 units ... Cutler-Hammer Westinghouse

  • Upload
    others

  • View
    21

  • Download
    0

Embed Size (px)

Citation preview

Page 1: US C LISTED C UL US service. LISTED UL C UL C UL US UL ... › customer › alcuel › customerpages › ... · 13 units 14 units 15 units 17 units 20 units ... Cutler-Hammer Westinghouse

8 0 0 . 2 2 3 . 0 4 8 3 | a l l c u r r e n t . c o m

For over 30 years we’ve served Electrical Distributors with Engineered Products and Need It Now service.

Our experience enables us to provide Custom Assembled Products and Solutions...

accurate, on-time results that exceed your expectations.

LISTED

LISTED

01224364860728496

108120132144156168180192204216

CAMERA-READY LOGOTYPE OF THE UL LISTING MARK FOR CANADA AND THE U.S.

These Marks are registered by Underwriters Laboratories Inc.

UL US LISTEDC

UL US LISTEDC

UL US LISTEDC UL US LISTEDC

UL USC

LISTED

C USUL

UL USC

LISTED

UL USC

LISTEDUL USC

LISTED

The minimum height of the registered trademark symbol shall be 3/64 ofan inch. When the overall diameter of the UL Mark is less than 3/8 of an inch,the trademark symbol may be omitted if it is not legible to the naked eye.

Please note:Not all of these elements should be used together with the same UL Mark.The word “LISTED” would only be used once — either to the right of or below the UL Mark (as shown).

The font for all letter forms is Helvetica Condensed Black, except forthe trademark symbol , which is Helvetica Condensed Medium.�No other fonts are acceptable.

RELATIVE DESIGN & PROPORTIONS OF THE UL LISTING MARK FOR CANADA AND THE U.S.

KEY TO DIMENSIONSUL MarkABCDEFGH

8 units13 units14 units15 units17 units20 units24 units29 units

“C” and “US”

“LISTED”

PQR

T

34 units56 units75 units

201 units

IJKLMN0

30 units35 units59 units85 units87 units

176 units216 units

N

P P RJ F C F A F G J

MO

Q

KG B

D

HE

I

F

P

P

T

I

P

T

L

200-195S 10M/8/98

UL 508A /698A Panel ShopsNew Jersey - Texas - California Master Distributor

Services

•Engineering of Custom Control Systems

•Drilling and Tapping Services

•Assembly of Controls using Customer Supplied Components

•Breaker in-shop testing (NJ)

•Retrofit circuit breakers

•ATEX Rated Equipment

Products

•Industrial Control Panels

•MCC Buckets

•Enclosed Motor Control

•Assembled Circuit Breakers

•Assembled Hazardous Location Controls, Switches and Circuit Breakers

Industries Served

•Oil/Gas

•Chemical

•Onshore/Offshore Drilling

•Wastewater Treatment

•Pharmaceutical

•Food Processing

•Printing

•Mining

CUSTOM ASSEMBLED PRODUCTS & SERVICES

Page 2: US C LISTED C UL US service. LISTED UL C UL C UL US UL ... › customer › alcuel › customerpages › ... · 13 units 14 units 15 units 17 units 20 units ... Cutler-Hammer Westinghouse

8 0 0 . 2 2 3 . 0 4 8 3 | a l l c u r r e n t . c o m

CELEBRATING 30 YEARS OF SELLING EXCLUSIVELY THROUGH WHOLESALE DISTRIBUTORS

*Corporate Office I **Sales Location Only

NEW JERSEY fax: 856.365.8866 2500 McClellan Ave., Pennsauken, NJ 08109 *NEW JERSEY fax: 856.365.8866 1599 Admiral Wilson Blvd., Camden, NJ 08109ILLINOIS fax: 847.718.1442 800 Lunt Ave., Elk Grove Village, IL 60007LOUISIANA fax: 225.752.2102 6735 Exchequer Dr., Ste 120, Baton Rouge, LA 70809

TEXAS fax: 713.644.8401 4600 South Pinemont Dr., Houston, TX 77041WASHINGTON fax: 253.872.5324 6402 South 196th St., Kent, WA 98032CALIFORNIA fax: 805.658.9166 2259 Portola Road Unit B Ventura, CA 93003 **CALIFORNIA fax: 562.926.4907 14051 Stage Road, Santa Fe Springs, CA 90670

HEADQUARTERS PENNSAUKEN, NJ ~ SALES AND DISTRIBUTION LOCATIONS THROUGHOUT THE US

AFFILIATIONS AND MEMBERSHIPS

All Current sells exclusively to wholesale electrical distributors and is dedicated to supporting the market by lowering the

cost of sale and increasing your ability to serve. We specialize in assisting you to always say “yes” to your customers. Our

mission is to add value to the sales process by supporting your needs for hard to find products.

COMMITTED TO VALUE

•AssociateMemberofNAEDasa value added reseller serving the electrical distribution market

•Over100,000itemsinstock

•ProvideLateDayOrderFulfillment

•ExperiencedTechnicalSalesTeam

•18MonthWarrantyonAllProducts

•We carry a Comprehensive $36 Million Liability Insurance Policy

•NationalFootprint

•200,000 feet of warehouse space

GET TO KNOW ALL CURRENTGET TO KNOW

Page 3: US C LISTED C UL US service. LISTED UL C UL C UL US UL ... › customer › alcuel › customerpages › ... · 13 units 14 units 15 units 17 units 20 units ... Cutler-Hammer Westinghouse

Enclosed Control

8 0 0 . 2 2 3 . 0 4 8 3 | a l l c u r r e n t . c o m

LISTED

LISTED

01224364860728496

108120132144156168180192204216

CAMERA-READY LOGOTYPE OF THE UL LISTING MARK FOR CANADA AND THE U.S.

These Marks are registered by Underwriters Laboratories Inc.

UL US LISTEDC

UL US LISTEDC

UL US LISTEDC UL US LISTEDC

UL USC

LISTED

C USUL

UL USC

LISTED

UL USC

LISTEDUL USC

LISTED

The minimum height of the registered trademark symbol shall be 3/64 ofan inch. When the overall diameter of the UL Mark is less than 3/8 of an inch,the trademark symbol may be omitted if it is not legible to the naked eye.

Please note:Not all of these elements should be used together with the same UL Mark.The word “LISTED” would only be used once — either to the right of or below the UL Mark (as shown).

The font for all letter forms is Helvetica Condensed Black, except forthe trademark symbol , which is Helvetica Condensed Medium.�No other fonts are acceptable.

RELATIVE DESIGN & PROPORTIONS OF THE UL LISTING MARK FOR CANADA AND THE U.S.

KEY TO DIMENSIONSUL MarkABCDEFGH

8 units13 units14 units15 units17 units20 units24 units29 units

“C” and “US”

“LISTED”

PQR

T

34 units56 units75 units

201 units

IJKLMN0

30 units35 units59 units85 units87 units

176 units216 units

N

P P RJ F C F A F G J

MO

Q

KG B

D

HE

I

F

P

P

T

I

P

T

L

200-195S 10M/8/98

UL 508A / 698A Panel ShopsNew Jersey - Texas - California

YOUR CHOICE OF CONTROLLERS

YOUR CHOICEOF

COMBINATIONS DELIVERED

IN 1 DAY

YOUR CHOICE OF MODIFICATIONS

YOUR CHOICE OF DISCONNECTS YOUR CHOICE OF OVERLOADS

Thermal Magnetic Breaker Motor Circuit Protector Non Fused Switch Fused Switch Thermal Overloads Solid State Overloads

IEC Starters NEMA Starters

Control Transformers

Pilot Devices

Auxiliary Contacts

Timers

Contactors

Reversing and Multi Speed

Lighting Control

Page 4: US C LISTED C UL US service. LISTED UL C UL C UL US UL ... › customer › alcuel › customerpages › ... · 13 units 14 units 15 units 17 units 20 units ... Cutler-Hammer Westinghouse

8 0 0 . 2 2 3 . 0 4 8 3 | a l l c u r r e n t . c o m

*Corporate Office I **Sales Location Only

NEW JERSEY fax: 856.365.8866 2500 McClellan Ave., Pennsauken, NJ 08109 *NEW JERSEY fax: 856.365.8866 1599 Admiral Wilson Blvd., Camden, NJ 08109ILLINOIS fax: 847.718.1442 800 Lunt Ave., Elk Grove Village, IL 60007LOUISIANA fax: 225.752.2102 6735 Exchequer Dr., Ste 120, Baton Rouge, LA 70809

TEXAS fax: 713.644.8401 4600 South Pinemont Dr., Houston, TX 77041WASHINGTON fax: 253.872.5324 6402 South 196th St., Kent, WA 98032CALIFORNIA fax: 805.658.9166 2259 Portola Road Unit B Ventura, CA 93003 **CALIFORNIA fax: 562.926.4907 14051 Stage Road, Santa Fe Springs, CA 90670

HEADQUARTERS PENNSAUKEN, NJ ~ SALES AND DISTRIBUTION LOCATIONS THROUGHOUT THE US

Enclosed Control

Combination Starters

Non Combination Control with Cover

• Non-Combination Starters

• Combination Starters ○ Circuit Breakers ○Non-Fused Disconnect ○Fusible Disconnect

• Every Enclosure Type ○ NEMA 1, 3R, 12, 4X, 7/9

• Modifications ○ Start-Stop Pushbutton ○ Selector Switch ○ Indicating Lights ○ Control Transformers ○ Auxiliary Switches ○ Auxiliary Relays

• Completely Wired

• Custom Nameplates

• Heaters and Fuses Installed

WE STOCK

Page 5: US C LISTED C UL US service. LISTED UL C UL C UL US UL ... › customer › alcuel › customerpages › ... · 13 units 14 units 15 units 17 units 20 units ... Cutler-Hammer Westinghouse

• Explosion proof & dust tight enclosures• Safety switches• Enclosed circuit breakers• Non combination starters• Combination starters and contactors• Pushbutton stations• Panelboards: 1 PH, 3 PH, through

277/480VOLT 225AMP• Explosion proof fittings• Junction boxes• Instrument housings• Lighting contactors• Pushbutton components• Selector switch components• Pilot light components• Dual Pushbutton Operators

All Current is an ADALET Master Distributor.

This allows us to provide an extensive inventory for all of your hazardous environment applications.

Hazardous Control

WE STOCK

Master Distributor

8 0 0 . 2 2 3 . 0 4 8 3 | a l l c u r r e n t . c o m

LISTED

LISTED

01224364860728496

108120132144156168180192204216

CAMERA-READY LOGOTYPE OF THE UL LISTING MARK FOR CANADA AND THE U.S.

These Marks are registered by Underwriters Laboratories Inc.

UL US LISTEDC

UL US LISTEDC

UL US LISTEDC UL US LISTEDC

UL USC

LISTED

C USUL

UL USC

LISTED

UL USC

LISTEDUL USC

LISTED

The minimum height of the registered trademark symbol shall be 3/64 ofan inch. When the overall diameter of the UL Mark is less than 3/8 of an inch,the trademark symbol may be omitted if it is not legible to the naked eye.

Please note:Not all of these elements should be used together with the same UL Mark.The word “LISTED” would only be used once — either to the right of or below the UL Mark (as shown).

The font for all letter forms is Helvetica Condensed Black, except forthe trademark symbol , which is Helvetica Condensed Medium.�No other fonts are acceptable.

RELATIVE DESIGN & PROPORTIONS OF THE UL LISTING MARK FOR CANADA AND THE U.S.

KEY TO DIMENSIONSUL MarkABCDEFGH

8 units13 units14 units15 units17 units20 units24 units29 units

“C” and “US”

“LISTED”

PQR

T

34 units56 units75 units

201 units

IJKLMN0

30 units35 units59 units85 units87 units

176 units216 units

N

P P RJ F C F A F G J

MO

Q

KG B

D

HE

I

F

P

P

T

I

P

T

L

200-195S 10M/8/98

UL 508A / 698A Panel ShopsNew Jersey - Texas - California

Page 6: US C LISTED C UL US service. LISTED UL C UL C UL US UL ... › customer › alcuel › customerpages › ... · 13 units 14 units 15 units 17 units 20 units ... Cutler-Hammer Westinghouse

8 0 0 . 2 2 3 . 0 4 8 3 | a l l c u r r e n t . c o m

*Corporate Office I **Sales Location Only

NEW JERSEY fax: 856.365.8866 2500 McClellan Ave., Pennsauken, NJ 08109 *NEW JERSEY fax: 856.365.8866 1599 Admiral Wilson Blvd., Camden, NJ 08109ILLINOIS fax: 847.718.1442 800 Lunt Ave., Elk Grove Village, IL 60007LOUISIANA fax: 225.752.2102 6735 Exchequer Dr., Ste 120, Baton Rouge, LA 70809

TEXAS fax: 713.644.8401 4600 South Pinemont Dr., Houston, TX 77041WASHINGTON fax: 253.872.5324 6402 South 196th St., Kent, WA 98032CALIFORNIA fax: 805.658.9166 2259 Portola Road Unit B Ventura, CA 93003 **CALIFORNIA fax: 562.926.4907 14051 Stage Road, Santa Fe Springs, CA 90670

HEADQUARTERS PENNSAUKEN, NJ ~ SALES AND DISTRIBUTION LOCATIONS THROUGHOUT THE US

Hazardous Control

WE PROVIDE VALUE BY:

• UL 698A Panel Shops

• Installing and wiring of components

○ Control Transformers

○ Pilot Devices

○ Starters

• Drilling and Tapping

• Installing fittings

• CAD Drawings

• Selecting and installing fuses

• Installing panelboards

• Mounting Terminal Blocks in Junction Boxes

• Application assistance

• ATEX Capabilities

• Relays & More

Examples of Our Capabilities

Blank Cover

Handle InstalledPLC Control Panel wired with Pilot Devices & Meter Housing

Undrilled Bottom

Drilled and Tapped

Page 7: US C LISTED C UL US service. LISTED UL C UL C UL US UL ... › customer › alcuel › customerpages › ... · 13 units 14 units 15 units 17 units 20 units ... Cutler-Hammer Westinghouse

8 0 0 . 2 2 3 . 0 4 8 3 | a l l c u r r e n t . c o m

MCC BUCKETS

All Current Electrical Sales has been furnishing Replacement MCC Buckets to many industries.

Our Product Experts will help you meet your Need It Now requirements.

Our services include:

Allen Bradley

Centerline 2100 Bulletin 798

EatonCutler-HammerWestinghouse

11-3009800 Unitrol

Type WF10 Unitrol

5 StarFreedom Unitrol

Series 2100Advantage

Freedom 2100IT.

General Electric

7700 Line8000 Line

Evolution 9000

SiemensITE Gould

Allis-ChalmersFurnas

Gould 9600/5600

Allis-ChalmersMark1 & 2

Furnas Class 89 & Systems 89

Siemens Model 90, 95 & 95+

Tiastar

Square DSchneider

Model 3, 4, 5 & 6

Federal Pacific

FPE 5310FPE 5320

•Replacement for All Manufacturers•Aftermarket Support for Vintage MCC’s•Staged Bucket Replacement

•Genuine Component Parts•Renewal Parts Resources

LISTED

LISTED

01224364860728496

108120132144156168180192204216

CAMERA-READY LOGOTYPE OF THE UL LISTING MARK FOR CANADA AND THE U.S.

These Marks are registered by Underwriters Laboratories Inc.

UL US LISTEDC

UL US LISTEDC

UL US LISTEDC UL US LISTEDC

UL USC

LISTED

C USUL

UL USC

LISTED

UL USC

LISTEDUL USC

LISTED

The minimum height of the registered trademark symbol shall be 3/64 ofan inch. When the overall diameter of the UL Mark is less than 3/8 of an inch,the trademark symbol may be omitted if it is not legible to the naked eye.

Please note:Not all of these elements should be used together with the same UL Mark.The word “LISTED” would only be used once — either to the right of or below the UL Mark (as shown).

The font for all letter forms is Helvetica Condensed Black, except forthe trademark symbol , which is Helvetica Condensed Medium.�No other fonts are acceptable.

RELATIVE DESIGN & PROPORTIONS OF THE UL LISTING MARK FOR CANADA AND THE U.S.

KEY TO DIMENSIONSUL MarkABCDEFGH

8 units13 units14 units15 units17 units20 units24 units29 units

“C” and “US”

“LISTED”

PQR

T

34 units56 units75 units

201 units

IJKLMN0

30 units35 units59 units85 units87 units

176 units216 units

N

P P RJ F C F A F G J

MO

Q

KG B

D

HE

I

F

P

P

T

I

P

T

L

200-195S 10M/8/98

UL 508A / 698A Panel ShopsNew Jersey - Texas - California

Page 8: US C LISTED C UL US service. LISTED UL C UL C UL US UL ... › customer › alcuel › customerpages › ... · 13 units 14 units 15 units 17 units 20 units ... Cutler-Hammer Westinghouse

8 0 0 . 2 2 3 . 0 4 8 3 | a l l c u r r e n t . c o m

*Corporate Office I **Sales Location Only

NEW JERSEY fax: 856.365.8866 2500 McClellan Ave., Pennsauken, NJ 08109 *NEW JERSEY fax: 856.365.8866 1599 Admiral Wilson Blvd., Camden, NJ 08109ILLINOIS fax: 847.718.1442 800 Lunt Ave., Elk Grove Village, IL 60007LOUISIANA fax: 225.752.2102 6735 Exchequer Dr., Ste 120, Baton Rouge, LA 70809

TEXAS fax: 713.644.8401 4600 South Pinemont Dr., Houston, TX 77041WASHINGTON fax: 253.872.5324 6402 South 196th St., Kent, WA 98032CALIFORNIA fax: 805.658.9166 2259 Portola Road Unit B Ventura, CA 93003 **CALIFORNIA fax: 562.926.4907 14051 Stage Road, Santa Fe Springs, CA 90670

HEADQUARTERS PENNSAUKEN, NJ ~ SALES AND DISTRIBUTION LOCATIONS THROUGHOUT THE US

Vintage and Current Motor Control Center Solutions

A Single Source for all of your MCC Replacement needs

Example of Square D Model 3 Modernization

WE CAN MEET ALL OF YOUR REQUIREMENTS:

• Modernization component upgrades

• Replace Thermal Overload Relays with Solid State

• Stab replacement or re-conditioning

• Component replacement

• Test reliability of existing units

• Simple or complete re-furbishing

• Variable frequency drive retrofit

• Restore degraded units to “like new” condition

• Valuable down-time savings

MCC BUCKETS

Refurbished stabs

Old door

Old obsolete worn out unit

Stabs installed on unit

Refurbished door

Unit after modernization

Page 9: US C LISTED C UL US service. LISTED UL C UL C UL US UL ... › customer › alcuel › customerpages › ... · 13 units 14 units 15 units 17 units 20 units ... Cutler-Hammer Westinghouse

Pushbuttons andControl Stations

ACE CUSTOM CONTROLS CAN DELIVER THE EXACT CONFIGURATION THATIS NEEDED TO RUN YOUR PROCESS WHEN YOU NEED IT.

Enclosure Options• NEMA 1, 3, 3R, 4, 4X, & 13• Die Cast• Polyester• Stainless Steel• Class 1 Division 2 Groups

B, C, & D• Class 1 Zone 2 Group IIB• Pendant• Special Sizes

Device Options• 16, 22, 30 MM• Oil Tight• Water Tight• Explosion Proof• All Manufacturers

Connection Options• DeviceNet• Wiring Harness• Special Plugs• Terminal Block• Jumpers• Contact block

interconnection

8 0 0 . 2 2 3 . 0 4 8 3 | a l l c u r r e n t . c o m

LISTED

LISTED

01224364860728496

108120132144156168180192204216

CAMERA-READY LOGOTYPE OF THE UL LISTING MARK FOR CANADA AND THE U.S.

These Marks are registered by Underwriters Laboratories Inc.

UL US LISTEDC

UL US LISTEDC

UL US LISTEDC UL US LISTEDC

UL USC

LISTED

C USUL

UL USC

LISTED

UL USC

LISTEDUL USC

LISTED

The minimum height of the registered trademark symbol shall be 3/64 ofan inch. When the overall diameter of the UL Mark is less than 3/8 of an inch,the trademark symbol may be omitted if it is not legible to the naked eye.

Please note:Not all of these elements should be used together with the same UL Mark.The word “LISTED” would only be used once — either to the right of or below the UL Mark (as shown).

The font for all letter forms is Helvetica Condensed Black, except forthe trademark symbol , which is Helvetica Condensed Medium.�No other fonts are acceptable.

RELATIVE DESIGN & PROPORTIONS OF THE UL LISTING MARK FOR CANADA AND THE U.S.

KEY TO DIMENSIONSUL MarkABCDEFGH

8 units13 units14 units15 units17 units20 units24 units29 units

“C” and “US”

“LISTED”

PQR

T

34 units56 units75 units

201 units

IJKLMN0

30 units35 units59 units85 units87 units

176 units216 units

N

P P RJ F C F A F G J

MO

Q

KG B

D

HE

I

F

P

P

T

I

P

T

L

200-195S 10M/8/98

UL 508A / 698A Panel ShopsNew Jersey - Texas - California

YOUR CONTROL STATION SOLUTION STARTS HERE

MANY DEVICES TO CHOOSE

CONTROL STATION EXAMPLES

All Shapes, Sizes and Enclosure TypesExplosion ProofPendant StationsCustom Design and Build

Page 10: US C LISTED C UL US service. LISTED UL C UL C UL US UL ... › customer › alcuel › customerpages › ... · 13 units 14 units 15 units 17 units 20 units ... Cutler-Hammer Westinghouse

•MaterialHandling

•WasteWaterTreatment

•MachineControl

•ProcessControl

•PumpControl

•CraneandHoistControl

•CompressorControl

•HazardousLocations

•LEDIndicatingLights•Multi-functiondevices•Push-PullandPush-Push•TwisttoRelease•GuardsandLocks•SpecialEngraving•LogicLevelContactBlocks•Non-corrosivedevices•Fittingsandhubsinstalled•Anynumberofdevices

CONTROL STATIONS FOR ANY APPLICATION VARIETY OF DEVICES AND OPTIONS

8 0 0 . 2 2 3 . 0 4 8 3 | a l l c u r r e n t . c o m

*Corporate Office I **Sales Location Only

NEW JERSEY fax: 856.365.8866 2500 McClellan Ave., Pennsauken, NJ 08109 *NEW JERSEY fax: 856.365.8866 1599 Admiral Wilson Blvd., Camden, NJ 08109ILLINOIS fax: 847.718.1442 800 Lunt Ave., Elk Grove Village, IL 60007LOUISIANA fax: 225.752.2102 6735 Exchequer Dr., Ste 120, Baton Rouge, LA 70809

TEXAS fax: 713.644.8401 4600 South Pinemont Dr., Houston, TX 77041WASHINGTON fax: 253.872.5324 6402 South 196th St., Kent, WA 98032CALIFORNIA fax: 805.658.9166 2259 Portola Road Unit B Ventura, CA 93003 **CALIFORNIA fax: 562.926.4907 14051 Stage Road, Santa Fe Springs, CA 90670

HEADQUARTERS PENNSAUKEN, NJ ~ SALES AND DISTRIBUTION LOCATIONS THROUGHOUT THE US

GET TO KNOW ALL CURRENT

800.223.0483 | www.allcurrent.com

Pushbuttons and Control Stations

Control Stations for any application Material Handling Waste Water

Treatment Machine Control Process Control Pump Control Crane and Hoist Control Compressor Control Hazardous Locations

Variety of Devices and options LED Indicating Lights Multi-function devices Push-Pull and Push-Push Twist to Release Guards and Locks Special Engraving Logic Level Contact Blocks Non-corrosive devices Fittings and hubs installed Any number of devices

We are your solution for supplying Control Stations – Call us today!

WE ARE YOUR SOLUTION FOR SUPPLYING CONTROL STATIONS – CALL US TODAY!

Pushbuttons andControl Stations

Page 11: US C LISTED C UL US service. LISTED UL C UL C UL US UL ... › customer › alcuel › customerpages › ... · 13 units 14 units 15 units 17 units 20 units ... Cutler-Hammer Westinghouse

Enclosed Panelboards

EXPLOSION PROOF PANELBOARDS

STAINLESS STEEL PANELBOARDS

LET ACE CUSTOM CONTROLS PROVIDE YOUR ENCLOSED PANELBOARDS.

8 0 0 . 2 2 3 . 0 4 8 3 | a l l c u r r e n t . c o m

Back Fed Main Breaker Panelboard

LightingPanelboard

Power PanelMain Lugs Only

Designed for use in Class 1, Division 1, Zone 1 areas such as petroleum refineries, chemical or petrochemical facilities, the X1PB panelboards are used to controllighting & appliance, power circuits & power distribution in applications requiring branch power distribution, over current, and short circuit protection.

AllX1PBpanelboardsareequippedwithEatonPow-R-Linechassis with copper bus, isolated neutral and ground bar. Select the branch breakers and we will install them along with the external handles. Gasketed covers provide IP66 and NEMA 4/4X rated protection for a water tight seal, and stainless steel cover bolts, removable hinges, and breather/drain are included as standard features.

Master Distributor

STANDARD FEATURES:•Type4X,12&13EnclosedPanelboard

•Circuit Breaker Operating Handles–aluminum handles (stainless steel handle option available, consult factory) with stainless steel bushings and shafts. Color coded handles are spring loaded allowing for the door to be closed with the breaker toggle in any position.

•Lockplate provision provides padlocking for each breaker.

•Individual operating labels identify breaker position.

•Circuit Directory Holder Card

•Also available in a Swing Panel Dead Front Enclosure

•UL/cUL Listed

Page 12: US C LISTED C UL US service. LISTED UL C UL C UL US UL ... › customer › alcuel › customerpages › ... · 13 units 14 units 15 units 17 units 20 units ... Cutler-Hammer Westinghouse

8 0 0 . 2 2 3 . 0 4 8 3 | a l l c u r r e n t . c o m

*Corporate Office I **Sales Location Only

NEW JERSEY fax: 856.365.8866 2500 McClellan Ave., Pennsauken, NJ 08109 *NEW JERSEY fax: 856.365.8866 1599 Admiral Wilson Blvd., Camden, NJ 08109ILLINOIS fax: 847.718.1442 800 Lunt Ave., Elk Grove Village, IL 60007LOUISIANA fax: 225.752.2102 6735 Exchequer Dr., Ste 120, Baton Rouge, LA 70809

TEXAS fax: 713.644.8401 4600 South Pinemont Dr., Houston, TX 77041WASHINGTON fax: 253.872.5324 6402 South 196th St., Kent, WA 98032CALIFORNIA fax: 805.658.9166 2259 Portola Road Unit B Ventura, CA 93003 **CALIFORNIA fax: 562.926.4907 14051 Stage Road, Santa Fe Springs, CA 90670

HEADQUARTERS PENNSAUKEN, NJ ~ SALES AND DISTRIBUTION LOCATIONS THROUGHOUT THE US

AFFILIATIONS AND MEMBERSHIPS