Upload
others
View
1
Download
0
Embed Size (px)
Citation preview
UR Upgrade Program
2 UR Upgrade Program
9/9/2015
Outline
1. Introduction
2. Why Upgrading?
3. Who Is Affected?
4. How to Upgrade?
5. Benefits of the New Upgraded UR
1. Introduction
. . . Proven State of the Art Family of P&C Systems
UR Protection and Control Devices
• Common hardware
• Plug and play modules
• Reduced stock of spare parts
• Reduced maintenance cost
• Swappable modules
Modular design that delivers unparalleled flexibility and fights obsolescence
2. Why Upgrading?
Lifespan of Digital Protection Relays… • Determining lifespan factors of any digital relays are based on environmental
conditions, application of the relay and individual component age.
• Old relays may:
• Lower the reliability and process uptime
• Increase in service/maintenance costs
• Lower personnel safety
Proactive action is crucial → Solution: Retrofit
• Lower the electrical equipment lifespan
• Not comply with new requirements (i.e.
smart grids)
• Have problem with replacing components
unavailability due to obsolesce
• Typical lifespan Bathtub curve
• Infant Mortality
• Weak Solder joint; cracked ceramic caps or silicon die;
Design margin issues
• Steady State
• Single event burnout; Silver/NiCr corrosion; Opto-
isolator/LED degradation; Airborn particles
• Wearout
• Electrolytic caps; solder joint fatigue; connector
corrosion; Package delamination
UR Power Supply Life Expectancy Continuous Design Improvements
1H Power Supply – 1998 -> 2004
• Design life 10 years @40DegC, confirmed by field return data
• At 10 year point, the device failure rate is expected to increase at a rate of 1% per year
• Life of Electrolytic capacitors affected by heat and electrical stress
• Analog subsystem susceptible to failure of C27/C28 (8V Rail) (GER-4477)
• Failure of 27/C28 (8V Rail) may result in incorrect metering and false trip
RH Power Supply – 2004 -> 2014 (Jun)
• Utilized newer Capacitor technology to increase design life of 15 years @40DegC
• At 15 year point, the device failure rate is expected to increase at a rate of 1% per year
• Added 200mS ride through capability
• KEMET Capacitor batch issue described in GER4012B (2005/2006)
SH Power Supply – 2014 (Jun)
• Eliminated C27/C28 & others, leaving only 1 long life reservoir capacitor for ride through
• Utilized new technology to give design life of 40 years at @45DegC
• 28% more output power, without increase in heat dissipation
• Micro controller on board to manage output rail sequencing
• Voltage rail monitoring to ensure analog & digital subsystems operate correctly
Solutions – Retrofit by Replacing
• Cost of new relay, accessories and spare parts
• Re-engineering costs(new drawings, settings,
trainings, tests, etc.)
• Panels modification costs(new cut-out, door,
blank/drop-in plates, wiring, relocation, etc.)
• Service, maintenance and outage costs
Validate complete IED
-New complete hardware
-New complete Firmware
Create new Engineering standards
-Create new drawings
-Create new settings files with re-configured I/O
-Create testing procedures
-Retrain all staff on new IED & S/W
Remove existing IED
-Disconnect all wiring
-Remove IED
Create new panel cut-out
Install new IED
-Install IED
Reconnect all wiring
-Test all wiring (point – to-point)
Commission new IED
-Test all IED functions
-Test all I/O from and to other devices and equipment
-Test all wiring
-Perform system tests
Months Months Days Days 1-2 Days
Solutions – Retrofit by Upgrading Using UR Replacement kits
• No need to replace the relay
• Not offered by all vendors
• No panel modification needed
• Compatible with the existing protection and control system
• Limited service, maintenance and outage costs
• Enhanced functionalities and new generation relay features
• Relays more than almost 10-year old are concerned.
Modular design provides seamless upgrades resulting in average savings of 50% on retrofit project.
10 UR Upgrade Program
9/9/2015
UR Upgrade Program Fast Replacement – Eliminates Rewiring & Reconfiguration Unique Modular draw out mechanism (no panel cut-out required)
Easy upgrade & retrofit without disturbing existing wiring
Draw out aged relay modules and install new modules - plug & use (no reconfiguring of I/O wiring to fit new terminal boards)
Minimize training & labor hours required for commissioning – reduce service costs (no wiring test and terminal inspection required, No tools required (replace all modules))
• UR Setup software compatibility (easy transfer of existing protection setting schemes)
• File conversion, file version selector, and file comparison tools for quick setpoint file modifications
Validate Only changes
-Only new CPU and DSP
-New firmware features
Update existing Engineering Standards
-Update drawings
-Convert settings files
-Update testing procedures
-Train staff only on changes
No need to remove existing UR
-Disconnect only communication wiring
-UR chassis remains
-No new panel cut-out
Replace UR modules
-Remove old modules
-Install new modules
-Reconnect communications wiring
Maintenance test UR
-Check all analog values
-Test enabled functions
-Test all UR I/O only
Weeks Weeks <1 Hour Hours Hours
11 UR Upgrade Program
9/9/2015
UR Upgrade Program Easy transition to enhanced next generation functions
Upgrade for a better reliability and security
• Proactive approach to compensate for electronic component aging
• New technological advancements on UR protective relaying systems
• Commitment on enhanced product performance improvement
Simplified process for ease of upgrade transition
• Arrange for advance replacements to meet scheduled outages
• Hardware upgrade kits available with an Upgrade Guide for seamless upgrades
Economical solution to revamp existing installed base products
• Proactive upgrade would minimize maintenance labor costs and maximize process uptime
• Offers special discounted rates on upgrade
3. Who Is Affected?
13 UR Upgrade Program
9/9/2015
Upgrade Recommendation Upgrade recommended for UR Devices 10 years and older
The recommended replacement for UR relays (versions 3.5 or below):
• CPU versions T, U, V DSP versions L, M, N, R, S
• Firmware versions: 7.xx and above
If existing standards dictate other versions, they can be offered.
CPU and DSP modules have to be changed, i.e. version 3 DSP’s are not compatible with later versions.
UR 3 DSP Recommended UR 7 DSP
8A 8L
8B 8M
8C 8N
8D 8R
UR 3 CPU Recommended UR 7 CPU
A T, U or V. If 2 serial ports required, UR 9E
C T or U
D T or U
UR Relays with Firmware 3.5 and below CPU Cross Reference
UR Relays with Firmware 3.5 DSP Cross Reference
4. How to Upgrade?
15 UR Upgrade Program
9/9/2015
Upgrade Process Simple selection, Fast replacement, Easy set-up, Economical
Determine if upgrade is required.
• UR model and serial numbers
• Existing firmware version
Obtain the replacement
kits.
• CPU-type required
• Specific firmware required
• Additional software options
• Contact local GE sales office
Settings conversions.
• By latest EnerVista UR setup software
Modules replacement
• Follow UR3 upgrade guide (GET-8550)
Pre-in-service checks and
testing
• Visual verification
•In-service maintenance tests
•Out-of-service maintenance tests
“Do it yourself guide: Upgrade guide!”
5. Benefits of the New Upgraded UR
Single Platform, Scalable Solution
“Incrementally Scalable” Single Platform Solution
UR Feature Enhancements-I Proactive approach towards enhanced quality, reliability and functionality
Protection • Multiple new applications • Breaker and a half capabilities for D60 and L90 • Breaker failure support for B30 and G60 • Incipient cable fault detection for F35 and F60 • New Trip Bus for all UR models • Watt-metric ground for D60, F60 and L90 • Voltage-dependent overload and Broken Rotor Bar for M60 • 100% stator and rotor using the GPM and Split-phase protection (G60)
• Teleprotection Inputs/Outputs for: • B30, C30, C60, D60, F35, F60, G60, M60, T35 and T60
Control • Enhanced breaker control:
• block open/close; • double-point status per phase with alarming
• Autorecloser extended to 4 shots, selectable activation modes and breaker initiated • Additional control functions (Capacitor, PID regulator, AVR)
UR Feature Enhancements-II From Firmware V3.50 to V7.xx
Monitoring • New elements for Power system components (CTs) monitoring
• Breaker arching for B30, C60, D60, F35, G60, L90, M60, T35 and T60 • PMU functionality on D60, L90, G60, G60, F60, T60 • Internal hardware monitors on DSP and voltage rails
Communication • Enhanced IEC 61850, IEC62439 PRP and IEEE 1588 PTP, IEC 103 • Hard-fiber (61850 Process Bus) • Enhancements to PMU and other protocols
Reliability • Enhanced environmental monitoring and capabilities • New DSP failure mode with enhanced diagnostic DSP • Enhanced design, validation and manufacturing processes
UR Feature Enhancements-III Bringing more to power system installations…
Software • Selected settings auto-configuration • One click records retrieval • Settings templates and more
Security • Role-based access control • Audit & recovery
• CyberSentry level 1 with Radius and Syslog support • Meet well known NERC CIP standard • Additional features: access control, intrusion detection & prevention, audit
Platform Enhancement • Enhanced CPU and DSP • Upgraded I/O & inter relay modules • New power supply • Multiple languages
UR Hardware Enhancements More Powerful CPU and Power Supply…
CPU
• Speed: much faster (400MHz vs. 64MHz) • Memory: 8 times more for events and oscillography and much faster (from SDRAM to DDR2) • Three independent Ethernet ports (MAC and IP addresses) • Maintains backward compatibility with existing hardware • Three types of CPU Modules
Power Supply
• Higher input voltage range (88 to 400VDC vs. 88 to 300VDC) • Overall output power increased (45W vs. 35W) • Voltage Rail monitoring on all rails vs. none • Isolation voltage level (2300VAC vs. 2000VAC) • limited use of electrolytic capacitors for ride-through 1 vs. 27 in LV & 10 in HV) • Microcontroller based power supply control vs. none • Over temperature protection vs. none
22 UR Upgrade Program
9/9/2015
• Best solution for relay retrofit without replacing it
• Not offered by other vendors
• Lower service, maintenance and outage time
• Enhanced reliability, Improved Performance
• Easy transition to enhanced next generation relay systems
• Ease of upgrade / replacement
• Compatibility with smart grid emerging needs.
• Use of well known UR strengths
• Under 10 year warranty coverage
Summary