28
Unvented and Vented Stainless Hot Water Cylinders www.joule-pl.pl

Unvented and Vented Stainless Hot Water Cylinders · PDF filelines in BS 6700. Guidance should be sought for unusual applications, e.g. high flow rate showers, large baths, etc. Hot

Embed Size (px)

Citation preview

Page 1: Unvented and Vented Stainless Hot Water Cylinders · PDF filelines in BS 6700. Guidance should be sought for unusual applications, e.g. high flow rate showers, large baths, etc. Hot

Unvented and Vented Stainless Hot Water Cylinders

www.joule-pl.pl

Page 2: Unvented and Vented Stainless Hot Water Cylinders · PDF filelines in BS 6700. Guidance should be sought for unusual applications, e.g. high flow rate showers, large baths, etc. Hot

Introduction

NSAI Agrément

All white version also available: NSAI_Agrement_Wht

NSAI_Agrement_2Col

NSAI_Agrement_Rev

NSAI_Agrement_1Col

NSAI_Agrement_Blk

NSAI Certification

All white version also available: NSAI_Certification_Wht

NSAI_Certification_2Col

NSAI_Certification_Rev

NSAI_Certification_1Col

NSAI_Certification_Blk

Joule was formed in 2008 to offer the heating, plumbing and hardware merchant network a ser-vice that was based on product expertise and knowledge, large stock holding, short delivery times and a nationwide distribution network. The strength of this offering can be seen in the quality and innovation of our product range in renewa-bles, hot water production & storage. From humble beginnings Joule rapidly grew to become Ireland’s premier supplier of solar thermal and hot water storage solutions. In 2010 Joule opened its fast manufacturing facil-ity in Dublin. This facility had an output capacity of 24,000 units per annum working on a single shift per day. Along with the manufacturing, Joule also opened Irelands most advanced solar thermal training centre. Joule believe that we must work with all stakeholders in providing the customer an outstanding service and investing in training for installers is just another small example of this philosophy.

In 2011 Joule opened its first distribution centre in Cheshire, UK. The UK arm of the Joule Group is rapidly expanding. With Joule’s innovative product range and drive for excellence in customer service, demand is quickly growing through our Cheshire distribution centre. Joule UK is continuing to offer customers excellence in product & service and the result of this will help Joule UK to become one of the UK’s favourite Solar Thermal & Hot Water Storage suppliers. Joule Poland is the Joule Group’s latest develop-ment. Demand for high quality stainless steel hot water storage cylinders is rising across Europe and particularly in Poland. Joule’s product range is proving very popular and to meet this demand the Joule Group has recently opened a distribution centre in Poland. This demand is a testament to Joule’s quality in both product and service.

Page 3: Unvented and Vented Stainless Hot Water Cylinders · PDF filelines in BS 6700. Guidance should be sought for unusual applications, e.g. high flow rate showers, large baths, etc. Hot

3 / 20

JOULE PLT +48 (0) 128811171 F +48 (0) 814709046 E [email protected] W www.joule-pl.pl

Domestic Selection Sizing GuideThese recommendations are based on the guide-lines in BS 6700. Guidance should be sought for unusual applications, e.g. high flow rate showers, large baths, etc.

Hot Water Demand Bedrooms Gas / Oil Indirect Units

Electric Indirect Units

1 Standard Bath or Shower

Bedsit / 1 Bed 150 150

2-3 Bed 150 200

3-4 Bed 150 200

1 Standard Bath 2-3 Bed 150 200

3-4 Bed 150 200

1 Bath & En-Suite 2-3 Bed 150 200

3-4 Bed 150 200

4-5 Bed 200 200

2 Standard Baths 2-3 Bed 200 200

3-4 Bed 200 200

4-5 Bed 200 250

3 Standard Baths 3-4 Bed 250 300

4-5 Bed 250 300

5-6 Bed 300 300

Commercial Selection Sizing GuideThese recommendations are based on the guide-lines in BS 6700. Guidance should be sought for unusual applications, e.g. high flow rate showers, large baths, etc.

Typical Commercial Application Indirect Units

Large House 6 Bed / 4 Bathrooms 400

Guest House 8 Bed / 4 Bathrooms 2 x 300

Small Hotel 8 Bed / 8 Bathrooms 3 x 200

Sports Pavilion 25 People / 4 Showers 2 x 300

Sports Pavilion 25 People / 6 Showers 3 x 200

Students House 25 People / 3 Bathrooms 3 x 300

Old People’s Home 60 People / 10 Showers 5 x 300 (each supplying 2 bathrooms)

Selecting the correct size of cylinder requires con-sideration of a nuber of variables, including the volume of water needed, the energy source and the space available. Calculating the colume needed can be achieved by adding together the individual volumes of each appliance that uses hot water and how frequently it is used. The energy source is the next variable to consider, as it will have a direct impact on the cylinder size.

CycloneResponding rapidly to changing market expecta-tions we have evolved the Joule Cyclone vented and unvented stainless steel cylinders. All our Cylinders are formed from stainless steel, con-tinuing our phylosophy of only using the finest materials. We are so confident in our construction that we offer a 25 year limited guarantee* on most of the Cyclone range. To keep a breast with devel-opments the Joule Cyclone range has many key advantages.

Butt WeldingAll Cyclone cylinders are butt seam welded, this gives greater rigidity and removes the threat of crevice corrosion associated with some cylinders.

Flexible ConnectionsJoule recognise that sometimes the need for 1” hot & cold connections with adaptable 3/4” fitting is a key way forward for the installer.

Sensor PocketsKey to ensuring the cylinder works and performs to its optimal ability is the sensor pockets, these determine how the unit calls for heat from the external source. The Cyclone has 10mm solar sen-sor pockets ensuring the probets from the solar fit correctly and effectively, we also ensured the aquastat pocket is produce to flair out holding the stat firmly in place

CoilsWith the continued introduction of heat sources Joule has looked closely at the best possible option for coils within the Cyclone Range, we use both conventional rigid plain tube and CSST high effiency coil to ensure all our units perform to the highest possible standards, this flexibility ensures Joule can produce any heat surface area required.

Key advantages

Page 4: Unvented and Vented Stainless Hot Water Cylinders · PDF filelines in BS 6700. Guidance should be sought for unusual applications, e.g. high flow rate showers, large baths, etc. Hot

Cyclone Direct These cylinders are designed to work with elec-tricity only. The water is heated using electrical elements and they do not have any ability to heated by oil or gas boilers.

Directefficient electrically heated hot water

3/4” Secondary Return

Immersion Heater1” Adaptable Cold Water Inlet

1/2” T&P Relief Valve (fitted)

1” Adaptable Hot Water Draw

Immersion Heater

Page 5: Unvented and Vented Stainless Hot Water Cylinders · PDF filelines in BS 6700. Guidance should be sought for unusual applications, e.g. high flow rate showers, large baths, etc. Hot

PSM11150/D PSM11155/D PSM11160/D PSM13660/D PSM15660/D PSM15771/D PSM19071/D

Volume (l) 125 150 200 250 300 400 500

Height (mm) 1110 1110 1110 1360 1560 1570 1900

Diameter (mm) 500 550 600 600 600 710 710

Weight Empty (kg) 28 32 36 45 49 64 77

Insulation (mm) 50 50 40 40 40 50 50

Reheat Time of 3/4 Cold Water - - - - - - -

Reheat Time of 3/4 Cold Water (3 kW Immersion) 48 63 91 118 141 175 222

EN12897 Heat Exchange kW - - - - - - -

Dedicated Solar Volume - - - - - - -

Standard Standing Loss kWh/Day 1.23 1.41 1.8 2.15 2.28 2.41 2.54

Technical Information 5 / 20

9 kW Titanium Immersion • High Use• Quicker Recovery• Hard Water

3 kW Titanium Immersion

• High Use• Hard Water

6 kW Titanium Immersion

• High Use• Quick Recovery• Hard Water

9 kW Incoloy Immersion

• Intermittent Use• Quicker Recovery• Soft Water

3 kW Incoloy Immersion

• Intermittent Use• Soft Water

6 kW Incoloy Immersion

• Intermittent Use• Quick Recovery• Soft Water

JOULE PLT +48 (0) 128811171 F +48 (0) 814709046 E [email protected] W www.joule-pl.pl

1 0 0 2 00 0 00Temperature and Pressure Relief Valve

Expansion Vessel

Dual ThermostatHigh Flow RateInlet Control Set

Incoloy Long 240V 3kW Immersion Heater

15/22 Tundish 22mm Thermostatic Mixing Valve

Expansion Vessel Hose

22 mm 2 Port Motorzed Diverting Valve

Page 6: Unvented and Vented Stainless Hot Water Cylinders · PDF filelines in BS 6700. Guidance should be sought for unusual applications, e.g. high flow rate showers, large baths, etc. Hot

Indirectefficient indirectly heated hot water

IndirectThese cylinders are designed to be heated indrect-ly using of an oil or gas boiler. They come complete with one electric Element to intermittently support the water heating system.

3/4” Secondary Return

Immersion Heater

3/4” Boiler Return

Plain Aquastat Pocket

3/4” Boiler Return

1” Adaptable Cold Water Inlet

1/2” T&P Relief Valve (fitted)

1” Adaptable Hot Water Draw

Page 7: Unvented and Vented Stainless Hot Water Cylinders · PDF filelines in BS 6700. Guidance should be sought for unusual applications, e.g. high flow rate showers, large baths, etc. Hot

PSM11150 PSM11155 PSM11160 PSM13660 PSM15660 PSM15771 PSM19071

Volume (l) 125 150 200 250 300 400 500

Height (mm) 1110 1110 1110 1360 1560 1570 1900

Diameter (mm) 500 550 600 600 600 710 710

Weight Empty (kg) 32 36 42 51 55 73 88

Insulation (mm) 50 50 40 40 40 50 50

Reheat Time of 3/4 Cold Water 19 21 26 26 32 35 35

Reheat Time of 3/4 Cold Water (3 kW Immersion) 48 63 91 118 141 175 222

EN12897 Prim. Heat Exchng (kW) 16 16 18 22 22 28 35

EN12897 Solar Heat Exchng (kW) - - - - - - -

Coil Surface (m2) 0.58 0.58 0.7 0.7 1.2 1.3 1.4

Standard Standing Loss (kWh/Day) 1.23 1.41 1.8 2.15 2.28 2.41 2.54

Technical Information

JOULE PLT +48 (0) 128811171 F +48 (0) 814709046 E [email protected] W www.joule-pl.pl

7 / 20

1 0 0 1 00 0 00Temperature and Pressure Relief Valve

Expansion Vessel

Dual ThermostatHigh Flow RateInlet Control Set

Incoloy Long 240V 3kW Immersion Heater

15/22 Tundish 22mm Thermostatic Mixing Valve

Expansion Vessel Hose

22 mm 2 Port Motorzed Diverting Valve

Page 8: Unvented and Vented Stainless Hot Water Cylinders · PDF filelines in BS 6700. Guidance should be sought for unusual applications, e.g. high flow rate showers, large baths, etc. Hot

Twin Coilefficient solar supported indirectly heated hot water

Twin CoilThese cylinders are designed to be heated indrect-ly using of an oil or gas boiler. They come complete with one electric Element to intermittently support the water heating system.

Eco80With the requirement for more energy efficient solu-tions, Joule offer the full Cyclone range with Eco80 specification. The eco 80 range increasea insula-tion thickness to 80mm nominal.

3/4” Boiler Flow

3/4” Secondary Return

1” Adaptable Cold Water Inlet

3/4” Boiler Return

3/4” Solar Flow

1/2” T&P Relief Valve (fitted)

Plain Aquastat Pocket

Plain Aquastat Pocket

Plain Solar Sensor

3/4” Solar Return

Plain Solar Sensor

1” Adaptable Hot Water Draw

Immersion Heater

Page 9: Unvented and Vented Stainless Hot Water Cylinders · PDF filelines in BS 6700. Guidance should be sought for unusual applications, e.g. high flow rate showers, large baths, etc. Hot

PSM11160/S PSM13660/S PSM15660/S PSM15771/S PSM19071/S

Volume (l) 200 250 300 400 500

Height (mm) 1110 1360 1560 1570 1900

Diameter (mm) 600 600 600 710 710

Weight Empty (kg) 45 55 60 76 89

Weight Full (kg) 245 245 360 476 589

Insulation (mm) 40 40 40 50 50

Reheat Time of 3/4 Cold Water 26 26 32 35 35

Reheat Time of 3/4 Cold Water (3 kW Immersion) 91 118 141 175 222

EN12897 Prim. Heat Exchng (kW) 18 22 22 28 35

EN12897 Solar Heat Exchng (kW) 16 18 18 22 22

Dedicated Solar Volume (l) 110 135 160 210 260

Solar Coil Surface (m2) 0.7 0.7 1.2 1.3 1.4

Primary Coil Surface (m2) 0.58 0.77 0.8 1.02 1.28

Standard Standing Loss (kWh/Day) 1.8 2.15 2.28 2.41 2.54

Eco80 Standing Loss (kWh/Day) 1.59 1.69 1.91 2.15 2.25

Technical Information

When using Eco80, dimensions will change to allow for extra insulation.

JOULE PLT +48 (0) 128811171 F +48 (0) 814709046 E [email protected] W www.joule-pl.pl

9 / 20

1 0 0 1 00 0 00Temperature and Pressure Relief Valve

Expansion Vessel

Dual ThermostatHigh Flow RateInlet Control Set

Incoloy Long 240V 3kW Immersion Heater

15/22 Tundish 22mm Thermostatic Mixing Valve

Expansion Vessel Hose

22 mm 2 Port Motorzed Diverting Valve

Page 10: Unvented and Vented Stainless Hot Water Cylinders · PDF filelines in BS 6700. Guidance should be sought for unusual applications, e.g. high flow rate showers, large baths, etc. Hot

Triple Coilefficient solar supported indirectly heated hot water complete with auxiliary heating coil

Triple CoilJoule Cyclone triple coil cylinders have been designed specifically with multi fuel applications in mind. Featuring a purpose designed solar coil, which allows maximum heat transfer of solar energy into the stored water and a 28mm (1”) gravity coil which facilitates the use of gravity fed solid fuel systems. The cylinders are suitable for use with a wide range of solar systems now available and are

an efficient and environmentally friendly way of providing domestic hot water. Combine this with the use of excess heat from your solid fuel system during winter, this cylinder allows you to optimise the use of heat during both summer and winter. Cyclone triple coil cylinders also offer the benefit of mains pressure hot water - powerful showers and fast filling baths.

3/4” Boiler Flow

3/4” Secondary Return

1” Adaptable Cold Water Inlet

3/4” Boiler Return

3/4” Solar Flow

1” Boiler Return

T&P Relief Valve (fitted)

Plain Aquastat Pocket

Plain Aquastat Pocket

Plain Solar Sensor

3/4” Solar Return

1” Boiler Flow

Plain Solar Sensor

1” Adaptable Hot Water Draw

Immersion Heater

Page 11: Unvented and Vented Stainless Hot Water Cylinders · PDF filelines in BS 6700. Guidance should be sought for unusual applications, e.g. high flow rate showers, large baths, etc. Hot

PSM11160/3 PSM13660/3 PSM15660/3 PSM15771/3 PSM19071/3

Volume (l) 200 250 300 400 500

Height (mm) 1110 1360 1560 1570 1900

Diameter (mm) 600 600 600 710 710

Weight Empty (kg) 50 59 67 83 96

Insulation (mm) 40 40 40 50 50

Weight Full (kg) 250 309 363 480 594

Reheat Time of 3/4 Cold Water 26 26 32 35 35

Solar Coil Surface (m2) 0.7 0.7 1.2 1.3 1.4

Primary Coil Surface (m2) 0.58 0.77 0.8 1.02 1.28

Secondary Coil Surface (m2) 0.58 0.58 0.58 0.58 0.58

Dedicated Solar Volume (l) 110 135 160 210 260

Standard Standing Loss (kWh/Day) 1.8 2.15 2.28 2.41 2.54

Technical Information

JOULE PLT +48 (0) 128811171 F +48 (0) 814709046 E [email protected] W www.joule-pl.pl

11 / 20

1 0 0 1 00 0 00Temperature and Pressure Relief Valve

Expansion Vessel

Dual ThermostatHigh Flow RateInlet Control Set

Incoloy Long 240V 3kW Immersion Heater

15/22 Tundish 22mm Thermostatic Mixing Valve

Expansion Vessel Hose

22 mm 2 Port Motorzed Diverting Valve

Page 12: Unvented and Vented Stainless Hot Water Cylinders · PDF filelines in BS 6700. Guidance should be sought for unusual applications, e.g. high flow rate showers, large baths, etc. Hot

Thermal Storeincorporating mains pressure (boosted) domestic hot water

Triple CoilThe Joule Copper and Stainless Steel Thermal Stores are the next generation of heating and hot water pro-duction. The Joule thermal store has been designed with multi fuel heating systems in mind. The cylin-der allows an easy installation of solid fuel, solar and boiler easily and effectively. The thermal store allows pressurised hot water heated from solid fuel safely and fully compliant with current plumbing practices

and standards. The tank operates like a hot water cyl-inder in reverse. The tank is completely full of heating system water, the domestic hot water flows through a network of coils up through the centre of the tank sup-plying you with high flow rate pressurised hot water at piping hot temperatures. The thermal store is ideally suited to providing solar heat support and domestic hot water production simultaneously and easily.

1” Connection

1” Connection

1” Connection

1” Connection

Solar 3/4” Return

Solar 3/4” Flow

Link 1”

Aquastat Pocket

1” Connection

Aquastat Pocket

Immersion Heater

Link 1”

Aquastat Pocket

1” Connection

Solar Sensor

DHW 1” Flow

1” Connection

1” Connection

Aquastat Pocket

Hot Water Draw

Page 13: Unvented and Vented Stainless Hot Water Cylinders · PDF filelines in BS 6700. Guidance should be sought for unusual applications, e.g. high flow rate showers, large baths, etc. Hot

TSS-250/S TSS-300/S TSS-400/S TSS-500/S

Volume (l) 250 300 400 500

Height (mm) 1360 1560 1570 1900

Diameter (mm) 600 600 710 710

Weight Empty (kg) 55 60 76 89

Insulation (mm) 50 50 50 50

1st Hour Hot Water (l/h) 50 °C 187.5 225 300 375

Max Flow Rate (l/min) 50 °C 17 20 22 24

Dedicated Solar Volume (l) 135 160 210 260

Standing Loss Cylinder (kWh/Day) 1.9 2.0 2.41 2.54

Solar Coil Surface (m2) 1.15 1.15 1.2 1.3

Primary Coil Surface (m2) 2.30 2.30 2.30 3.45

Technical Information

JOULE PLT +48 (0) 128811171 F +48 (0) 814709046 E [email protected] W www.joule-pl.pl

13 / 20

1 0 0 1 00 0 00Temperature and Pressure Relief Valve

Expansion Vessel

Dual ThermostatHigh Flow RateInlet Control Set

Incoloy Long 240V 3kW Immersion Heater

15/22 Tundish 22mm Thermostatic Mixing Valve

Expansion Vessel Hose

22 mm 2 Port Motorzed Diverting Valve

Page 14: Unvented and Vented Stainless Hot Water Cylinders · PDF filelines in BS 6700. Guidance should be sought for unusual applications, e.g. high flow rate showers, large baths, etc. Hot

Heat Pumpspecifically designed to work with heat pumps and other low temperature heat sources

Heat Pump CylindersJoule Cyclone Heatpump cylinders have been designed to work with air source, ground source and other types of low temperature heat source appliances. The cylinder is manufactured with coil in coil technology. Coil in coil technology allows for greater surface area coils to be installed in standard sized cylinder units. The inner coil dis-sipates more heat at lower temperatures improving

the efficiency of the overall system. the cylinders can be manufactured with any size coil required. Please call Joule for details of coil sizes of units on the shelf and feel free to ask Joule for a differ-ent specification cylinder if that is what you require. Our in house engineers are on hand to offer advice on cylinder specifications for different applications.

1” Heat Pump Flow

3/4” Secondary Return

1” Adaptable Cold Water Inlet

1” Heat Pump Return

3/4” Solar Flow

1/2” T&P Relief Valve (fitted)

Plain Solar Sensor

Plain Aquastat Pocket

Plain Solar Sensor3/4” Solar Return

Plain Solar Sensor

1” Adaptable Hot Water Draw

Immersion Heater

Plain Solar Sensor

Page 15: Unvented and Vented Stainless Hot Water Cylinders · PDF filelines in BS 6700. Guidance should be sought for unusual applications, e.g. high flow rate showers, large baths, etc. Hot

Heat Pump Cylinder with 1 coil

Volume (l) 200 250 300 400 500

PSM14053/HG PSM17753/HG PSM15660/HG PSM15771/HG PSM19071/HG

Height (mm) 1400 1775 1560 1570 1900

Diameter (mm) 530 530 600 710 710

Primary Coil Surface (m2) 2.5 2.8 3.2 3.2 4

Insulation (mm) 40 40 40 50 50

Weight Empty (kg) 65 72 80 97 109

Standard Standing Loss (kWh/Day) 1.8 2.15 2.28 2.41 2.54

Technical Information

JOULE PLT +48 (0) 128811171 F +48 (0) 814709046 E [email protected] W www.joule-pl.pl

15 / 20

Heat Pump Cylinder with 2 coilsPSM14053/HG+S PSM17753/HG+S PSM15660/HG+S PSM15771/HG+S PSM19071/HG+S

Height (mm) 1400 1775 1560 1570 1900

Diameter (mm) 530 530 600 710 710

Primary Coil Surface (m2) 2.5 2.8 3.2 3.2 4

Solar Coil Surface (m2) 1.1 1.2 1.2 1.3 1.4

Insulation (mm) 40 40 40 50 50

Weight Empty (kg) 69 76 84 101 114

Standard Standing Loss (kWh/Day) 1.8 2.15 2.28 2.41 2.54

1 0 0 1 00 0 00Temperature and Pressure Relief Valve

Expansion Vessel

Dual ThermostatHigh Flow RateInlet Control Set

Incoloy Long 240V 3kW Immersion Heater

15/22 Tundish 22mm Thermostatic Mixing Valve

Expansion Vessel Hose

22 mm 2 Port Motorzed Diverting Valve

3/4” Secondary Return

1” Adaptable Cold Water Inlet

1/2” T&P Relief Valve (fitted)

Page 16: Unvented and Vented Stainless Hot Water Cylinders · PDF filelines in BS 6700. Guidance should be sought for unusual applications, e.g. high flow rate showers, large baths, etc. Hot

Tank in Tank Ecofast recovery tank-in-tank cylinder - perfect partner to condensing boiler

Tank in Tank EcoThe fastest recovery hot water cylinder available

• 20 min recovery of Domestic Hot Water• Suitable for Heat Pumps because of large

Surface Area• Suitable for Solar Thermal• Suitable for pellet or log burners• Design reduces boiler cycling & improves

boiler efficiency• Most advanced Domestic Hot Water storage

cylinder available• Tank design reduces limescale buildup

3/4” Solar Return

DHW Tank

1” Connection

T/P Relief ValveCold Water SupplyHor Water SupplySecondary Return

3/4” Solar Flow

1” Connection

1” Connection

1” Connection

1” Connection1” Connection

1” Connection

1” Connection

Page 17: Unvented and Vented Stainless Hot Water Cylinders · PDF filelines in BS 6700. Guidance should be sought for unusual applications, e.g. high flow rate showers, large baths, etc. Hot

Technical Information

JOULE PLT +48 (0) 128811171 F +48 (0) 814709046 E [email protected] W www.joule-pl.pl

17 / 20

STANDARD

Volume (l) 150 200 250 300 400 500

Height (mm) 1085 1085 1335 1535 1535 1880

Diameter (mm) 500 560 560 560 660 660

Weight Empty (kg) 30 34 43 47 62 75

Weight Full (kg) 180 234 293 347 462 575

Reheat Indirect Total Minutes 21 26 26 32 35 35

Reheat 3 kW Immersion Total Min. 63 91 118 141 175 222

Dedicated Solar Volume - - - - - -

Standard Standing Loss kWh/Day 1.45 1.84 2.19 2.32 2.45 2.58

Eco80 Standing Loss kWh/Day 1.39 1.63 1.73 1.95 2.19 2.29

Litres in first 30 min 40 °C 320 321 418 558 686 922

Litres in first 30 min 45 °C 263 275 348 464 582 790

Litres in first 30 min 60 °C 175 161 206 274 358 504

Litres in first hour 40 °C 938 1063 1225 1633 1872 2666

Litres in first hour 45 °C 751 911 1003 1338 1559 2285

Litres in first hour 60 °C 426 536 590 786 935 1368

Continuous Flow (l/h) 827 890 967 1289 1423 2093

Continuous Flow (l/h) 673 763 786 1048 1172 1794

Continuous Flow (l/h) 378 450 461 614 693 1037

Absorbed Power (kW) 29 31 32 43 48 73

1 1 1 1 11 1 10Temperature and Pressure Relief Valve

Expansion Vessel

Dual ThermostatHigh Flow RateInlet Control Set

Incoloy Long 240V 3kW Immersion Heater

15/22 Tundish 22mm Thermostatic Mixing Valve

Expansion Vessel Hose

22 mm 2 Port Motorzed Diverting Valve

Page 18: Unvented and Vented Stainless Hot Water Cylinders · PDF filelines in BS 6700. Guidance should be sought for unusual applications, e.g. high flow rate showers, large baths, etc. Hot

Large Stainless Steel Hot Water CalorifierJoule manufactures stainless steel cylinders in all capacities up to 3,000L. Choosing stainless steel over mild steel for hot water storage is a sensi-ble option as it removes the need for a sacrificial anode and maintenance of that part. The quality of the cylinders is ensured with factory testing to 12 bar. Stainless steel construction offers numerous advantages over mild steel

• Better corrosion resistance properties• Coil type heat exchangers• Removable U type heat exchangers• Option for inspection hatch• Soft foam jacket insulation option• Dense PU foam and wipe clean outer casing

option• Horizontal or vertical standing• Connections available for use with plate heat

exchangers• Stainless Steel grade used 316L• Option for cylinder to be manufactured to cus-

tomers’ requirements

Stainless Hot Water Calorifier

Page 19: Unvented and Vented Stainless Hot Water Cylinders · PDF filelines in BS 6700. Guidance should be sought for unusual applications, e.g. high flow rate showers, large baths, etc. Hot

LARGE STAINLESS STEEL HOT WATER CLARIFIERS

Volume (l) 600 750 1000 1250 1500 2000 2500 3000

Height (mm) 2100 2100 2100 2100 2400 2700 2700 2700

Diameter (mm) 610 750 900 945 945 1100 1200 1270

Weight Empty (kg) 110 132 155

Weight Full (kg) 710 882 1155

Working Pressure (bar) 6-8 6-8 6-8 6-8 6-8 6-8 6-8 6-8

Tested Pressure (bar) 9-12 9-12 9-12 9-12 9-12 9-12 9-12 9-12

• Dense foam insulation and outer casing only available up to 945mm shell diameter. Bigger than this requires soft foam jacket (100mm)• Dimensions indicated (height & diameter) are un-insulated shell dimensions and insulation thickness must be added to get overall dimensions

Technical Information

ELECTRICAL HEATING OPTIONS

Lenght (mm) Phase Thread Connection (“) Material Watt Density per (inch2)

6 kW 457 Single Phase 2.25” BSP Incloy 825

9 kW 457 Single Phase 2.25” BSP Incloy 825 90

12 kW 406 Three Phase 2.25” BSP Incloy 825 73

18 kW 610 Three Phase 2.25” BSP Incloy 825 71

INSPECTION HATCHES

Connection Type Material

200mm Diameter Flange Stainless Steel

300mm Diameter Flange Stainless Steel

400mm Diameter Flange Stainless Steel

INSULATION OPTIONS

Thickness Type

Soft Foam Jacket 100 mm Removable Jacket

Dense PU Foam 50 mm Not Removable

COILS & HEAT EXCHANGERS

Diameter (mm) Recovery Time (mins) Working Pressure (bar) Notes

Internal Coil 22 / 28 / 32 / 38 30 / 40 / 60 / 90 / 120 6-8 Internal, not removable

U Type 25-50 30 / 40 / 60 / 90 / 120 6-8 Fully removable

• Primary connections can be selected from available options• Other coil and u type heat exchanger specifications available on request

Technical Information

JOULE PLT +48 (0) 128811171 F +48 (0) 814709046 E [email protected] W www.joule-pl.pl

19 / 20

0 0 0 0 00 0 00Temperature and Pressure Relief Valve

Expansion Vessel

Dual ThermostatHigh Flow RateInlet Control Set

Incoloy Long 240V 3kW Immersion Heater

15/22 Tundish 22mm Thermostatic Mixing Valve

Expansion Vessel Hose

22 mm 2 Port Motorzed Diverting Valve

Page 20: Unvented and Vented Stainless Hot Water Cylinders · PDF filelines in BS 6700. Guidance should be sought for unusual applications, e.g. high flow rate showers, large baths, etc. Hot

Stainless Steel Buffer StorageJoule manufactures a large range of stainless buffer tanks with different coil configurations. The larg-est capacity stainless steel buffer tank is 3,000L. Buffer tanks can come complete with numerous coil configurations from direct to quad coil and all in-between. The coil types available are pumped high temperature, heat pump, gravity and solar. The advantages of choosing a Joule stainless steel buffer storage tank are,

• Light weight compared with mild steel• BSP direct connections • BSP coil connections• Standard immersions available on request.• Eco 80 specification available (80mm insulation)

Examples of Use• With air and ground source heat pumps• For helping solar to heat support both heating

and hot water system• For use with bio mass and solid fuel heating

systems• As a heat store for electrically generated energy

Stainless Steel Buffer Storage

Page 21: Unvented and Vented Stainless Hot Water Cylinders · PDF filelines in BS 6700. Guidance should be sought for unusual applications, e.g. high flow rate showers, large baths, etc. Hot

LARGE STAINLESS STEEL BUFFER STORAGE TANKS

Volume (l) 125 150 170 200 250 300 400 500 600

Height (mm) 925 1085 1205 1085 1335 1335 1535 1880 2280

Diameter (mm) 550 550 550 600 600 600 710 710 710

Weight Empty (kg) 26 30 32 34 43 47 62 75 90

Weight Full (kg) 151 180 202 234 293 347 462 575 690

No. Direct Connections 7 7 7 9 9 9 9 9 9

Diameter of Direct Connections 1” 1” 1” 1” 1” 1” 1” 1” 1”

Drain Off 1/2” 1/2” 1/2” 1/2” 1/2” 1/2” 1/2” 1/2” 1/2”

Standard Standing Loss (kWh/Day) 1.23 1.41 1.53 1.8 2.15 2.28 2.41 2.54 2.71

Eco80 Standing Loss (kWh/Day) 1.16 1.36 1.44 1.69 1.91 2.15 2.25 2.38 2.59

ELECTRICAL HEATING OPTIONS

Lenght (mm) Phase Thread Connection (“) Material Watt Density per (inch2)

6 kW 457 Single Phase 2.25” BSP Incloy 825

9 kW 457 Single Phase 2.25” BSP Incloy 825 90

12 kW 406 Three Phase 2.25” BSP Incloy 825 73

18 kW 610 Three Phase 2.25” BSP Incloy 825 71

Technical Information

JOULE PLT +48 (0) 128811171 F +48 (0) 814709046 E [email protected] W www.joule-pl.pl

21 / 20

0 0 0 0 00 0 00Temperature and Pressure Relief Valve

Expansion Vessel

Dual ThermostatHigh Flow RateInlet Control Set

Incoloy Long 240V 3kW Immersion Heater

15/22 Tundish 22mm Thermostatic Mixing Valve

Expansion Vessel Hose

22 mm 2 Port Motorzed Diverting Valve

Page 22: Unvented and Vented Stainless Hot Water Cylinders · PDF filelines in BS 6700. Guidance should be sought for unusual applications, e.g. high flow rate showers, large baths, etc. Hot

Large Mild Steel Buffer StorageThese hot water tanks must be installed in a frost-protected room by a locally authorised specialist company.The vacuum enamelled tanks are suitable for normal drinking water. An appropriate electrical separation in accordance with the standards of engineering must be provided for mixed instal-lations. Any unused coupling sleeves must be suitably sealed.Please observe the regulations of the local works and the relevant standards when connecting. The connections must be installed pressure-proof. The component-tested safety devices must be installed in the cold water supply line according to local regulations, as can be seen in the illustration. The component-tested safety valve must have a

connecting diameter of DN 15 (up to 200 l, max. heating capacity 75kW) or DN 20 (over 200 l, max. heating capacity 150 kW) and must not be closable from the hot water tank. An indicating label with the following inscription must be affixed to the safety valve or its blow-off line:For safety reasons, water may exit from the blow-off line during heating! Do not close!

The operating overpressure specified on the rat-ing plate must not be exceeded; install pressure reducer, if necessary. A discharging device must be provided in the cold water when installing the connection.

Mild Steel Hot Water Calorifier

Page 23: Unvented and Vented Stainless Hot Water Cylinders · PDF filelines in BS 6700. Guidance should be sought for unusual applications, e.g. high flow rate showers, large baths, etc. Hot

Dimension 1500 2000 2500 3000

Type FFM / FRM / FRMR FFM / FRM / FRMR FFM / FRM / FRMR FFM / FRM / FRMR

Ø of tank with ISO 100 mm 1200 1300 1400 1400

Height with ISO 100 mm 2230 2420 2480 2870

Ø of tank without ISO 100 mm 1000 1100 1200 1200

HW/ventilation A 5/4” FT 2122 2313 2373 2768

Hot water B 5/4” FT 1825 1997 2027 2422

Circulation C 1” FT 1217 1252 1282 1682

Heating inflow, bottom D 5/4” FT 1067 1088 1122 1262

Heating return flow, bottom E 5/4” FT 362 448 482 482

Heating inflow, top O 5/4” FT 1722 1713 1927 2272

Heating return flow, bottom P 5/4” FT 1342 1393 1597 1942

CW / Discharge F 5/4” FT 80 168 80 100

Sensor G 1/2” FT 1825 1997 2027 2422

Correx anode H 3/4” FT 1494 1612 1642 1992

Electric heating element I 2” FT 1354 1472 1502 1852

Sensor K 1/2” FT 1167 1202 1232 1482

Flange L D = 240 837 847 877 877

Flange L D = 240 437 447 477 477

Heat exchanger M HE m2/l 3.5 / 29 4.0 / 36 4.0 / 40 5.0 / 47

Heat exchanger N HE m2/l 1.75 / 15 2.0 / 16 2.0 / 18 2.5 / 25

Weight (kg) 360 / 425 / 460 420 / 493 / 532 495 / 570 / 610 620 / 713 / 762

Tilted weight 2250 2440 2520 2890

Operating pressure (bar) 10 10 10 10

Operating temperature (°C) 95 95 95 95

Technical Information

JOULE PLT +48 (0) 128811171 F +48 (0) 814709046 E [email protected] W www.joule-pl.pl

23 / 20

0 0 0 0 00 0 00Temperature and Pressure Relief Valve

Expansion Vessel

Dual ThermostatHigh Flow RateInlet Control Set

Incoloy Long 240V 3kW Immersion Heater

15/22 Tundish 22mm Thermostatic Mixing Valve

Expansion Vessel Hose

22 mm 2 Port Motorzed Diverting Valve

Page 24: Unvented and Vented Stainless Hot Water Cylinders · PDF filelines in BS 6700. Guidance should be sought for unusual applications, e.g. high flow rate showers, large baths, etc. Hot

Large Mild Steel Buffer StorageJoule mild steel buffer tanks are suitable for all hot water central heating systems, regardless of whether they are powered by solid-fuel or oil-fired boilers, heat pumps, solar energy systems or con-tinuous flow heaters (gas or electric). Several buffer tanks can also be combined in a row (see technical data and accessories), meaning the tank volume can be adjusted individually depending on the requirements. Furthermore, the buffer tanks can also be used for cold water storage in cooling pro-cesses (up to 3 bar operating / system pressure) or heat recovery in industrial facilities.

• Nominal capacity of PSF/PSM/PSR/PSRR = 500 to 5000 litres

• Made from quality St 37-2 steel

• 100 mm ECO SKIN fleece insulation (up to 5,000 l)• Large-surface pipe array on PSR/PSRR models• 240 mm flange on PSF models for installing a

finned tube heta exchanger or built-in heater• Operating pressure = 3 bar, test pressure 4.5 bar

in buffer tank• Operating pressure max. 10 bar, test pressure 15

bar in pipe array on PSR/PSRR models• 4 regulating sleeve threads. „Female thread on

PSF/PSM and PSR/PSRR models• 2 x sensor channels for variable positioning of

sensor models• Operating temperature = 95°C (110°C in pipe array)• External powder coating (colour deviations) up

to 2000 litres• External anti-rust coating (from 3,000 l upwards)

new Eco Skin36%Energy Savinginstead if 21%

New Decisive Advantages• Everything from one source –

Buffer tank and insulation are manufactured by Joule

• Perfect corrosion protection – buffer tank with stoveenamelled powder coating externally

• Stable, form-retaining polysty-rene cover

• Perfect fit, therefore no chimney losses

• Insulated connection caps for the connections

• With ECO SKIN 2.0 save up to 3050,- on energy costs, over the life of a 1000 l - storage tank

Mild Steel Buffer Storage

Page 25: Unvented and Vented Stainless Hot Water Cylinders · PDF filelines in BS 6700. Guidance should be sought for unusual applications, e.g. high flow rate showers, large baths, etc. Hot

Diagonal Height (mm)

Dimensions (mm) Pipe array heating surface (mm) Array content (l)

Type A B C D F G H I J K L M Lower Upper Lower Upper

200 1105 670

300 1370 670

500 1670 220 620 1010 1390 1640 650 340 495 1725 220 1040 350 1.8 1.2 11 7.5

800 1750 260 630 1030 1430 1700 790 390 585 1785 260 1070 360 2.4 1.8 15 11

825 1900 260 685 1140 1595 1857 790 − − 1940 − − − − − − −

1000 2090 310 745 1250 1710 2050 790 390 720 2135 310 1160 540 3 2.4 19 15

1250 2100 330 705 1105 1480 1802 1000 − − 1905 − − − − − − −

1500 2270 380 825 1350 1760 2150 1000 415 800 2235 375 1260 500 3.6 2.4 22 15

2000 2460 320 900 1490 2020 2380 1100 423 800 2465 320 1420 540 4.2 2.8 26 18

3000 2650 375 985 1600 2205 2596 1250 460 720 2681 375 1665 540 4.5 3.0 29 19

4000 2740 405 1022 1639 2255 2669 1400 490 720 2754 405 1715 540 5.0 3.6 32 22

5000 2893 455 1065 1680 2285 2770 1600 540 720 2855 405 1745 540 6.0 4.2 39 26

Standby Energy Comsumption (kWh/24h)

Type 200 300 500 800 825 1000 1250 1500 2000 3000 4000 5000

PSF 2.9 3.1 3.3 4.1 4.2 4.3 5.1 5.4 6.3 7.7 8.7 10.0

PSM 2.7 2.9 3.0 3.7 3.8 3.9 4.7 5.0 5.9 7.3 8.3 9.6

PSR 2.8 2.9 3.1 3.9 4.0 4.1 4.9 5.2 6.1 7.5 8.5 9.8

PSRR 2.9 3.1 3.3 4.0 4.1 4.2 5.0 5.3 6.2 7.6 8.6 9.9

Standby Energy Consumption in kWh/24h according to EN 12897

PSFPSM Buffer Tank with

D240 Flange

PSMBuffer Tank with

6/4” Cooling Sleeves

PSR / PSRRBuffer Tank

(PSM with Pipe Array)

Technical Information

JOULE PLT +48 (0) 128811171 F +48 (0) 814709046 E [email protected] W www.joule-pl.pl

25 / 20

0 0 0 0 00 0 00Temperature and Pressure Relief Valve

Expansion Vessel

Dual ThermostatHigh Flow RateInlet Control Set

Incoloy Long 240V 3kW Immersion Heater

15/22 Tundish 22mm Thermostatic Mixing Valve

Expansion Vessel Hose

22 mm 2 Port Motorzed Diverting Valve

Page 26: Unvented and Vented Stainless Hot Water Cylinders · PDF filelines in BS 6700. Guidance should be sought for unusual applications, e.g. high flow rate showers, large baths, etc. Hot

Notes

Page 27: Unvented and Vented Stainless Hot Water Cylinders · PDF filelines in BS 6700. Guidance should be sought for unusual applications, e.g. high flow rate showers, large baths, etc. Hot

27 / 20

JOULE PLT +48 (0) 128811171 F +48 (0) 814709046 E [email protected] W www.joule-pl.pl

Page 28: Unvented and Vented Stainless Hot Water Cylinders · PDF filelines in BS 6700. Guidance should be sought for unusual applications, e.g. high flow rate showers, large baths, etc. Hot

Kylemore Park West, Ballyfermot, Dublin 10+353 (1) 623 7080 +353 (1) 626 [email protected]

Unit 17C&D Power Road, Plantation Bus. Pk. Bromborough, Wirral, CH62 3RN+44 (0) 1513 551 094+44 (0) 1513 568 [email protected]

23-200 Kraśnik, ul. Towarowa 34.+48 (0) 128811171+48 (0) [email protected]

JOULE IE JOULE UK JOULE PL

mail telfaxemlweb

mail

telfaxemlweb

mail telfaxemlweb

UNVENTED STAINLESS CyLINDERS